1
|
Wang L, Harshman SW, Liu S, Ren C, Xu H, Sallans L, Grever M, Byrd JC, Marcucci G, Freitas MA. Assaying pharmacodynamic endpoints with targeted therapy: flavopiridol and 17AAG induced dephosphorylation of histone H1.5 in acute myeloid leukemia. Proteomics 2011; 10:4281-92. [PMID: 21110323 DOI: 10.1002/pmic.201000080] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Histone H1 is commonly used to assay kinase activity in vitro. As many promising targeted therapies affect kinase activity of specific enzymes involved in cancer transformation, H1 phosphorylation can serve as potential pharmacodynamic marker for drug activity within the cell. In this study we utilized a phosphoproteomic workflow to characterize histone H1 phosphorylation changes associated with two targeted therapies in the Kasumi-1 acute myeloid leukemia cell line. The phosphoproteomic workflow was first validated with standard casein phosphoproteins and then applied to the direct analysis of histone H1 from Kasumi-1 nuclear lysates. Ten H1 phosphorylation sites were identified on the H1 variants, H1.2, H1.3, H1.4, H1.5 and H1.x. LC MS profiling of intact H1s demonstrated global dephosphorylation of H1.5 associated with therapy by the cyclin-dependent kinase inhibitor, flavopiridol and the Heat Shock Protein 90 inhibitor, 17-(Allylamino)-17-demethoxygeldanamycin. In contrast, independent treatments with a nucleotide analog, proteosome inhibitor and histone deacetylase inhibitor did not exhibit decreased H1.5 phosphorylation. The data presented herein demonstrate that potential of histones to assess the cellular response of reagents that have direct and indirect effects on kinase activity that alters histone phosphorylation. As such, this approach may be a highly informative marker for response to targeted therapies influencing histone phosphorylation.
Collapse
Affiliation(s)
- Liwen Wang
- Department of Chemistry, The Ohio State University, Columbus OH, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
2
|
Shah B, Kozlowski RL, Han J, Borchers CH. Emerging mass spectrometry-based technologies for analyses of chromatin changes: analysis of histones and histone modifications. Methods Mol Biol 2011; 773:259-303. [PMID: 21898261 DOI: 10.1007/978-1-61779-231-1_16] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Mass spectrometry (MS) is rapidly becoming an indispensable tool for the analysis of posttranslational modifications (PTMs) of proteins, and particularly histone PTMs that regulate physiological processes. The more traditional bottom-up approach of searching for modifications on peptides rather than intact proteins (top-down) has proven useful for finding phosphorylation, acetylation, and ubiquitination sites. With the use of modern instrumentation and various MS-based techniques, peptides and their PTMs can be characterized in a high-throughput manner while still maintaining high sensitivity and specificity. In complement to bottom-up MS, recent advances in MS technology, such as high-field Fourier transform ion cyclotron resonance (FTICR)-mass spectrometry, have permitted the study of intact proteins and their modifications. On-line and off-line protein separation instruments coupled to FTICR-MS allow the characterization of PTMs previously undetectable with bottom-up approaches. The use of unique fragmentation techniques in FTICR-MS provides a viable option for the study of labile modifications. In this chapter, we provide a detailed description of the analytical tools - mass spectrometry in particular - that are used to characterize modifications on peptides and proteins. We also examine the applicability of these mass spectrometric techniques to the study of PTMs on histones via both the bottom-up and top-down proteomics approaches.
Collapse
Affiliation(s)
- Brinda Shah
- Department of Biochemistry and Microbiology, and the University of Victoria - Genome British Columbia Protein Center, University of Victoria, Victoria, BC, Canada
| | | | | | | |
Collapse
|
3
|
Gates MB, Tomer KB, Deterding LJ. Comparison of metal and metal oxide media for phosphopeptide enrichment prior to mass spectrometric analyses. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2010; 21:1649-59. [PMID: 20634090 PMCID: PMC2982680 DOI: 10.1016/j.jasms.2010.06.005] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/09/2010] [Revised: 06/08/2010] [Accepted: 06/11/2010] [Indexed: 05/15/2023]
Abstract
Several affinity resins consisting of ionic metals or metal oxides were investigated for their phosphopeptide enrichment capabilities with subsequent mass spectrometric analyses. Commercially-available enrichment metal oxide affinity chromatography (MOAC) resins using manufacturer's and/or published protocols were compared and evaluated for the most efficient and selective method that could be implemented as a standard enrichment procedure. From these comparative analyses, using a tryptic digest of casein proteins, it was determined that in our hands, two of the resins out-performed the others based on a variety of criteria, including the number of phosphorylation sites identified during MS analyses, the lower numbers of nonspecifically bound peptides observed, and the limits of detection. Applicability of these enrichment resins to a complex biological mixture was investigated. For this work, a mixture of avian histones was digested, subjected to titanium dioxide phosphopeptide enrichment, and analyzed by mass spectrometry. Eight phosphorylated tryptic peptides were observed following enrichment and subsequent LC/MS/MS analyses. Of note, seven of the eight phosphopeptides were not observed without titanium dioxide enrichment. From these analyses, four sites of phosphorylation were unequivocally determined, two of which have not been reported previously. Four additional phosphopeptides were observed; however, the site of phosphorylation could not be distinguished but was localized to one of two possible amino acids. These methods should aid in the investigation of proteins post-translationally modified with phosphate, especially those present at low concentrations as was demonstrated by successful enrichment at the femtomole level.
Collapse
Affiliation(s)
| | | | - Leesa J. Deterding
- Correspondence: Dr. Leesa Deterding, NIH, NIEHS, Laboratory of Structural Biology, Phone: (919)-541-3009, Fax: (919)-541-0220,
| |
Collapse
|
4
|
Abstract
Posttranslational modifications (PTMs) of proteins perform crucial roles in regulating the biology of the cell. PTMs are enzymatic, covalent chemical modifications of proteins that typically occur after the translation of mRNAs. These modifications are relevant because they can potentially change a protein's physical or chemical properties, activity, localization, or stability. Some PTMs can be added and removed dynamically as a mechanism for reversibly controlling protein function and cell signaling. Extensive investigations have aimed to identify PTMs and characterize their biological functions. This chapter will discuss the existing and emerging techniques in the field of mass spectrometry and proteomics that are available to identify and quantify PTMs. We will focus on the most frequently studied modifications. In addition, we will include an overview of the available tools and technologies in tandem mass spectrometry instrumentation that affect the ability to identify specific PTMs.
Collapse
Affiliation(s)
- Adam R Farley
- Department of Biochemistry, Vanderbilt University School of Medicine, Nashville, Tennessee, USA
| | | |
Collapse
|
5
|
Gruszecka A, Szymanska-Chargot M, Smolira A, Cytawa J, Michalak L. Role of the support material on laser desorption/ionization mass spectra. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2008; 22:925-929. [PMID: 18302166 DOI: 10.1002/rcm.3425] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
We report the results of experimental studies on the effects of sample supports in laser desorption/ionization mass spectrometry (LDI-MS). LDI time-of-flight (TOF) mass spectra obtained for C(60) and insulin samples deposited onto standard stainless steel substrate and/or onto some non-metallic materials (glass, scotch tape, floppy disc foil, Teflon foil, photocopy film), all recorded under identical, typical experimental conditions, have been compared with regard to their intensity and quality. The LDI investigations show that compared with stainless steel, glass and floppy disc foil sample supports boost (2-3.5 times) ion yields for C(60)(+) and C(60)(-) ions, respectively. The stainless steel and scotch tape sample supports are the best for the mass resolution of positive ions and the formation of (C(60))(n)(-) (n <or= 4) cluster ions, respectively. In the case of detection of insulin by matrix-assisted laser desorption/ionization (MALDI) we did not observe significant differences in sensitivity for the support materials tested. A mechanism of ion formation in the desorption plume is suggested.
Collapse
Affiliation(s)
- A Gruszecka
- Institute of Physics, Maria Curie-Sklodowska University, 20-031 Lublin, Poland
| | | | | | | | | |
Collapse
|
6
|
Jagannadham MV, Nagaraj R. Detecting the site of phosphorylation in phosphopeptides without loss of phosphate group using MALDI TOF mass spectrometry. ANALYTICAL CHEMISTRY INSIGHTS 2008; 3:21-9. [PMID: 19609387 PMCID: PMC2701175 DOI: 10.4137/aci.s497] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Phosphopeptides with one and four phosphate groups were characterized by MALDI mass spectrometry. The molecular ion of monophosphopeptide could be detected both as positive and negative ions by MALDI TOF with delayed extraction (DE) and in the reflector mode. The tetraphospho peptide could be detected in linear mode. When MS/MS spectra of the monophospho peptides were obtained in a MALDI TOF TOF instrument by CID, b and y ions with the intact phosphate group were observed, in addition the b and y ions without the phosphate group. Our study indicates that it is possible to detect phosphorylated peptides with out the loss of phosphate group by MALDI TOF as well as MALDI TOF TOF instruments with delayed extraction and in the reflector mode.
Collapse
|
7
|
Palumbo AM, Tepe JJ, Reid GE. Mechanistic Insights into the Multistage Gas-Phase Fragmentation Behavior of Phosphoserine- and Phosphothreonine-Containing Peptides. J Proteome Res 2008; 7:771-9. [DOI: 10.1021/pr0705136] [Citation(s) in RCA: 87] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Affiliation(s)
- Amanda M. Palumbo
- Department of Chemistry and Department of Biochemistry and Molecular Biology, Michigan State University, East Lansing, Michigan 48824
| | - Jetze J. Tepe
- Department of Chemistry and Department of Biochemistry and Molecular Biology, Michigan State University, East Lansing, Michigan 48824
| | - Gavin E. Reid
- Department of Chemistry and Department of Biochemistry and Molecular Biology, Michigan State University, East Lansing, Michigan 48824
| |
Collapse
|
8
|
Hardouin J. Protein sequence information by matrix-assisted laser desorption/ionization in-source decay mass spectrometry. MASS SPECTROMETRY REVIEWS 2007; 26:672-82. [PMID: 17492750 DOI: 10.1002/mas.20142] [Citation(s) in RCA: 109] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Proteins from biological samples are often identified by mass spectrometry (MS) with the two following "bottom-up" approaches: peptide mass fingerprinting or peptide sequence tag. Nevertheless, these strategies are time-consuming (digestion, liquid chromatography step, desalting step), the N- (or C-) terminal information often lacks and post-translational modifications (PTMs) are hardly observed. The in-source decay (ISD) occurring in a matrix assisted laser desorption/ionization (MALDI) source appears an interesting analytical tool to obtain N-terminal sequence, to identify proteins and to characterize PTMs by a "top-down" strategy. The goal of this review deals with the usefulness of the ISD technique in MALDI source in proteomics fields. In the first part, the ISD principle is explained and in the second part, the use of ISD in proteomic studies is discussed for protein identification and sequence characterization.
Collapse
Affiliation(s)
- Julie Hardouin
- Laboratoire de Biochimie des Protéines et Protéomique, Université Paris XIII, UMR CNRS 7033, 74 rue Marcel Cachin, 93 017, Bobigny Cedex, France.
| |
Collapse
|
9
|
|
10
|
Gevaert K, Staes A, Van Damme J, De Groot S, Hugelier K, Demol H, Martens L, Goethals M, Vandekerckhove J. Global phosphoproteome analysis on human HepG2 hepatocytes using reversed-phase diagonal LC. Proteomics 2006; 5:3589-99. [PMID: 16097034 DOI: 10.1002/pmic.200401217] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
We present a phosphoproteomics approach using diagonal RP chromatography as the basic isolation principle. Phosphopeptides present in a tryptic digest of total cellular lysates were first enriched by Fe3+-immobilized metal ion affinity chromatography. Further sorting of the phosphopeptides took place in three steps. First, the resulting peptide mixture was fractionated over reversed-phase chromatography. Second, peptides present in each fraction were treated with phosphatases. Third, the dephosphorylated peptides were then more hydrophobic and shifted towards a later elution interval from the contaminating non-phosphopeptides eluting at the same position as during the primary run. Since the phosphopeptides are isolated as their dephosphorylated form, additional proof for their original phosphorylation state was obtained by split-differential 16O-18O labeling. The method was validated with alpha-casein phosphopeptides and consecutively applied on HepG2 cells. We identified 190 phosphorylated peptides from 152 different proteins. This dataset includes 38 novel protein phosphorylation sites.
Collapse
Affiliation(s)
- Kris Gevaert
- Department of Medical Protein Research, Flanders Interuniversity Institute for Biotechnology, Ghent University, Ghent, Belgium
| | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Dashtiev M, Frankevich V, Zenobi R. Signal enhancement in matrix-assisted laser desorption/ionization by doping with Cu(II) chloride. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2005; 19:289-291. [PMID: 15609376 DOI: 10.1002/rcm.1768] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
|
12
|
Pröfrock D, Leonhard P, Ruck W, Prange A. Development and characterisation of a new interface for coupling capillary LC with collision-cell ICP?MS and its application for phosphorylation profiling of tryptic protein digests. Anal Bioanal Chem 2004; 381:194-204. [PMID: 15592818 DOI: 10.1007/s00216-004-2930-5] [Citation(s) in RCA: 58] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2004] [Revised: 10/13/2004] [Accepted: 10/25/2004] [Indexed: 11/26/2022]
Abstract
A comparison of different nebulisers for direct hyphenation of capillary and nano liquid chromatography (Cap-LC, Nano-LC) and quadrupole-based collision cell inductively coupled plasma mass spectrometry (CC-ICP-MS) for phosphorylation profiling of tryptic protein digests is described. Helium was used as cell gas and specially tuned instrumental conditions were used to achieve background minimisation at the mass of phosphorus, because of kinetic energy discrimination of the interfering polyatomic ions. The proposed set-up is based on a modified capillary electrophoresis interface and a home-made 4 mL spray chamber. It enables the use of gradient conditions with a highly concentrated organic mobile phase as often used in protein phosphorylation analysis, without the need to apply membrane desolvation for removal of the organic phase or further background minimisation. No significant signal suppression or other negative effects caused by the organic mobile phase occur, because of the low flow rates used in Cap-LC and the robust plasma conditions of the CC-ICP-MS instrument. A tryptic digest of beta-casein was investigated as model compound to demonstrate the applicability of the proposed set-up for phosphorylation profiling in protein analysis using quadrupole based collision-cell ICP-MS as phosphorus-specific detector. Detection limits for phosphorylated peptides down to the sub picomole level were obtained. As a complementary technique, electrospray ionisation tandem mass spectrometry (ESI-MS-MS) with data base searching was used for further characterisation of the phosphorylated peptides detected.
Collapse
Affiliation(s)
- Daniel Pröfrock
- GKSS Research Centre Geesthacht, Institute for Coastal Research, Marine Bioanalytical Chemistry, Max Planck Street 1, 21502 Geesthacht, Germany
| | | | | | | |
Collapse
|
13
|
Jensen ON. Modification-specific proteomics: characterization of post-translational modifications by mass spectrometry. Curr Opin Chem Biol 2004; 8:33-41. [PMID: 15036154 DOI: 10.1016/j.cbpa.2003.12.009] [Citation(s) in RCA: 375] [Impact Index Per Article: 18.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Post-translational modifications generate tremendous diversity, complexity and heterogeneity of gene products, and their determination is one of the main challenges in proteomics research. Recent developments in mass spectrometry based approaches for systematic, qualitative and quantitative determination of modified proteins promise to bring new insights on the dynamics and spatio-temporal control of protein activities by post-translational modifications, and reveal their roles in biological processes and pathogenic conditions. Combinations of affinity-based enrichment and extraction methods, multidimensional separation technologies and mass spectrometry are particularly attractive for systematic investigation of post-translationally modified proteins in proteomics.
Collapse
Affiliation(s)
- Ole Nørregaard Jensen
- Protein Research Group, Department of Biochemistry & Molecular Biology, University of Southern Denmark, DK-5230 Odense M, Denmark.
| |
Collapse
|
14
|
Veenstra TD. Proteome analysis of posttranslational modifications. ADVANCES IN PROTEIN CHEMISTRY 2004; 65:161-94. [PMID: 12964369 DOI: 10.1016/s0065-3233(03)01019-2] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/04/2023]
Affiliation(s)
- Timothy D Veenstra
- SAIC-Frederick Inc., National Cancer Institute at Frederick, Frederick, Maryland 21702, USA
| |
Collapse
|
15
|
Person MD, Monks TJ, Lau SS. An integrated approach to identifying chemically induced posttranslational modifications using comparative MALDI-MS and targeted HPLC-ESI-MS/MS. Chem Res Toxicol 2003; 16:598-608. [PMID: 12755589 DOI: 10.1021/tx020109f] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Identification of multiple and novel posttranslational modifications remains a major challenge in proteomics. The present approach uses comparative analysis by matrix-assisted laser/desorption ionization (MALDI) MS of proteolytic digests from control and treated proteins to target differences due to modifications, without initial assumption as to type or residue localization. Differences between modified and unmodified digest MS spectra highlight peptides of interest for subsequent tandem mass spectrometry (MS/MS) analysis. Targeted HPLC-electrospray ionization (ESI)-MS/MS is then used to fragment peptides, and manual de novo sequencing is used to determine the amino acid sequence and type of modification. This strategy for identifying posttranslational modifications in an unbiased manner is particularly useful for finding modifications produced by exogenous chemicals. Successful characterization of chemically induced posttranslational modifications and novel chemical adducts is given as an example of the use of this strategy. Histone H4 from butyrate-treated LLC-PK1 cells is separated on a gel into bands representing different overall charge state. Bands are analyzed by comparative MALDI-MS and LC-MS/MS to identify the sites of methylation and acetylation. Previous attempts to identify chemically adducted proteins in vivo have been unsuccessful in part due to a lack of understanding of the final adduct form. Cytochrome c is adducted in vitro with benzoquinone, an electrophilic metabolite of benzene capable of interacting with nucleophilic sites within proteins. De novo sequencing identifies a novel cyclized diquinone adduct species as the major reaction product, targeting Lys and His residues at two specific locations on the protein surface. This unpredicted reaction product is characterized using our unbiased methods for detection and demonstrates the important influence of protein structure on chemical adduction.
Collapse
Affiliation(s)
- Maria D Person
- Center for Molecular and Cellular Toxicology, Division of Pharmacology & Toxicology, College of Pharmacy, The University of Texas at Austin, 78712, USA
| | | | | |
Collapse
|
16
|
Doucette A, Craft D, Li L. Mass spectrometric study of the effects of hydrophobic surface chemistry and morphology on the digestion of surface-bound proteins. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2003; 14:203-214. [PMID: 12648927 DOI: 10.1016/s1044-0305(02)00909-1] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Our previous work has demonstrated that reversed-phase chromatographic micro-beads can be used to capture proteins from complex biological matrices and the surface-bound proteins can be enzymatically digested for protein identification by mass spectrometry (MS). Here we examine the peptides generated from digestion of proteins bound to various types of micro-bead surfaces in order to determine the effects of surface chemistry and surface morphology on the digestion process. Detailed examinations of site cleavages and sequence coverage are carried out for a tryptic digestion of cytochrome c adsorbed on reversed-phase polystyrene divinylbenzene (Poros R2 beads) versus C(18) bonded-phase silica beads. It is shown that although the surface does not completely hinder the digestion of cleavage sites of the protein, the digestion products are clearly different than those obtained from a solution digest. Specifically, a partial digestion results from surface digestion, resulting in a greater number of missed cleavages than a comparable solution digest. Subsequent comparisons of peptide mass maps generated from the digestion of various proteins on surfaces with altering chemistry (C(4), C(8), C(18), and R2 beads), or with different surface morphology, were performed. The results reveal that surface chemistry plays only a minor role in affecting the peptide mass maps, and surface morphology had no noticeable effects on the resulting peptide mass maps. It is also shown that the mass spectrometric detection method used to analyze the digested peptides can significantly influence the information content on cleavage sites and the extent of sequence coverage. The use of a combination of MALDI, LC/off-line MALDI, and LC/ESI MS is demonstrated to be crucial in revealing subtle changes in the peptide mass maps.
Collapse
Affiliation(s)
- Alan Doucette
- Department of Chemistry, University of Alberta, Edmonton, Alberta, Canada
| | | | | |
Collapse
|
17
|
Raska CS, Parker CE, Huang C, Han J, Glish GL, Pope M, Borchers CH. Pseudo-MS3 in a MALDI orthogonal quadrupole-time of flight mass spectrometer. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2002; 13:1034-1041. [PMID: 12322951 DOI: 10.1016/s1044-0305(02)00433-6] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Both the matrix selected and the laser fluence play important roles in MALDI-quadrupole/time of flight (QqTOF) fragmentation processes. "Hot" matrices, such as alpha-cyano4-hydroxycinnamic acid (HCCA), can increase fragmentation in MS spectra. Higher laser fluence also increases fragmentation. Typical peptide fragment ions observed in the QqTOF are a, b, and y ion series, which resemble low-energy CID product ions. This fragmentation may occur in the high-pressure region before the first mass-analyzing quadrupole. Fragment ions can be selected by the first quadrupole (Q1), and further sequenced by conventional MS/MS. This allows pseudo-MS3 experiments to be performed. For peptides of higher molecular weight, pseudo-MS3 can extend the mass range beyond what is usually accessible for sequencing, by allowing one to sequence a fragment ion of lower molecular weight instead of the full-length peptide. Peptides that predominantly show a single product ion after MS/MS yield improved sequence information when this technique is applied. This method was applied to the analysis of an in vitro phosphorylated peptide, where the intact enzymatically-generated peptide showed poor dissociation via MS/MS. Sequencing a fragment ion from the phosphopeptide enabled the phosphorylation site to be unambiguously determined.
Collapse
|
18
|
Yuan X, Desiderio DM. Protein identification with Teflon as matrix-assisted laser desorption/ionization sample support. JOURNAL OF MASS SPECTROMETRY : JMS 2002; 37:512-524. [PMID: 12112757 DOI: 10.1002/jms.307] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Protein identification is a critical step in proteomics, and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) plays an important role in that identification. Polytetrafluoroethylene (Teflon) was tested as a new MALDI sample support to improve protein identification. The tryptic peptides obtained from a model protein were bound to the surface of a modified MALDI sample holder via the hydrophobic interactions that occur between the Teflon surface and the peptide ion-pairs, and the affinity of alpha-cyano-4-hydroxycinnamic acid for the peptides. During that surface-binding step, the peptide mixture was also desalted and concentrated. A greater number of matched peptides and a larger sequence coverage were obtained for the proteins when Teflon was used as the sample support compared with conventional sample preparation methods and a stainless-steel surface. In addition, the characterization of a small amount of protein was improved with Teflon. Nine silver-stained protein spots obtained from 2-D gel of a human cerebrospinal fluid (CSF) proteome were identified by this method. Among the nine protein spots, peptide 6:c3c fragment and procollagen c-proteinase enhancer were not annotated in any published 2-D map of human CSF. A Teflon MALDI sample support is a low-cost, simple, and effective method that can be used to improve the quality of the MALDI mass spectrum of a complex tryptic peptide mixture, and to achieve a higher level of reliability and success in protein identification.
Collapse
Affiliation(s)
- Xianglin Yuan
- Charles B. Stout Neuroscience Mass Spectrometry Laboratory University of Tennessee Health Science Center, 847 Monroe Avenue, Memphis, Tennessee 38163, USA
| | | |
Collapse
|
19
|
Bennett KL, Stensballe A, Podtelejnikov AV, Moniatte M, Jensen ON. Phosphopeptide detection and sequencing by matrix-assisted laser desorption/ionization quadrupole time-of-flight tandem mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2002; 37:179-190. [PMID: 11857762 DOI: 10.1002/jms.271] [Citation(s) in RCA: 61] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
A prototype matrix-assisted laser desorption/ionization quadrupole time-of-flight (MALDI-TOF) tandem mass spectrometer was used to sequence a series of phosphotyrosine-, phosphothreonine- and phosphoserine-containing peptides. The high mass resolution and mass accuracy of the instrument allowed the localization of one, three or four phosphorylated amino acid residues in phosphopeptides up to 3.1 kDa. Tandem mass spectra of two different phosphotyrosine peptides permitted amino acid sequence determination and localization of one and three phosphorylation sites, respectively. The phosphotyrosine immonium ion at m/z 216.04 was observed in these MALDI low-energy CID tandem mass spectra. Elimination of phosphate groups was evident from the triphosphorylated peptide but not from the monophosphorylated species. The main fragmentation pathway for the synthetic phosphothreonine-containing peptide and for phosphoserine-containing peptides derived from beta-casein and ovalbumin was the beta-elimination of phosphoric acid with concomitant conversion of phosphoserine to dehydroalanine and phosphothreonine to 2-aminodehydrobutyric acid. Peptide fragment ions of the b- and y-type allowed, in all cases, the localization of phosphorylation sites. Ion signals corresponding to (b-17), (b-18) and (y-17) fragment ions were also observed. The abundant neutral loss of phosphoric acid (-98 Da) is useful for femtomole level detection of phosphoserine-peptides in crude peptide mixtures generated by gel in situ digestion of phosphoproteins.
Collapse
Affiliation(s)
- Keiryn L Bennett
- MDS Proteomics A/S, Staermosegaardsvej 6, DK-5230 Odense M, Denmark.
| | | | | | | | | |
Collapse
|
20
|
Abstract
Phosphorylation on serine, threonine and tyrosine residues is an extremely important modulator of protein function. Therefore, there is a great need for methods capable of accurately elucidating sites of phosphorylation. Although full characterization of phosphoproteins remains a formidable analytical challenge, mass spectrometry has emerged as an increasingly viable tool for this task. This review summarizes the methodologies currently available for the analysis of phosphoproteins by mass spectrometry, including enrichment of compounds of interest using immobilized metal affinity chromatography and chemical tagging techniques, detection of phosphopeptides using mass mapping and precursor ion scans, localization of phosphorylation sites by peptide sequencing, and quantitation of phosphorylation by the introduction of mass tags. Despite the variety of powerful analytical methods that are now available, complete characterization of the phosphorylation state of a protein isolated in small quantities from a biological sample remains far from routine.
Collapse
Affiliation(s)
- D T McLachlin
- The Rockefeller University, 1230 York Avenue, New York, NY 10021, USA.
| | | |
Collapse
|
21
|
Current awareness. Current literature in mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2001; 36:581-588. [PMID: 11391815 DOI: 10.1002/jms.92] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
In order to keep subscribers up-to-date with the latest developments in their field, John Wiley & Sons are providing a current awareness service in each issue of the journal. The bibliography contains newly published material in the field of mass spectrometry. Each bibliography is divided into 11 sections: 1 Books, Reviews & Symposia; 2 Instrumental Techniques & Methods; 3 Gas Phase Ion Chemistry; 4 Biology/Biochemistry: Amino Acids, Peptides & Proteins; Carbohydrates; Lipids; Nucleic Acids; 5 Pharmacology/Toxicology; 6 Natural Products; 7 Analysis of Organic Compounds; 8 Analysis of Inorganics/Organometallics; 9 Surface Analysis; 10 Environmental Analysis; 11 Elemental Analysis. Within each section, articles are listed in alphabetical order with respect to author (3 Weeks journals - Search completed at 7th. Mar. 2001)
Collapse
|
22
|
Janek K, Wenschuh H, Bienert M, Krause E. Phosphopeptide analysis by positive and negative ion matrix-assisted laser desorption/ionization mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2001; 15:1593-1599. [PMID: 11544598 DOI: 10.1002/rcm.417] [Citation(s) in RCA: 72] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
This article describes a simple procedure for the detection of phosphorylated peptides by comparable positive and negative ion mode matrix-assisted laser desorption/ionization mass spectrometry measurements. Based on studies with phosphorylated peptides (EAIXAAPFAK, X = pS, pT, pY) and their corresponding non-phosphorylated analogs, it was found that phosphopeptides, which are characterized by a low ionization efficiency in the positive ion mode, exhibit drastically increased signal intensities in the negative ion mode compared to their non-phosphorylated analogs. The effect was successfully used to identify phosphorylated sequences of the commonly used phosphoprotein standards, protein kinase A and beta-casein, by peptide mass fingerprint analyses of the corresponding Lys C and trypsin digests using both (positive and negative) ion modes. The comparison of positive and negative ion spectra of a given protein digest (relative intensity([M - H]-)/relative intensity([M + H]+)) can be used to identify any phosphopeptides present which may then be separated and analyzed further.
Collapse
Affiliation(s)
- K Janek
- Institute of Molecular Pharmacology, Robert-Rössle-Str. 10, 13125 Berlin, Germany
| | | | | | | |
Collapse
|