• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4726572)   Today's Articles (0)
For: Shi L, Vedantham S, Karellas A, Zhu L. X-ray scatter correction for dedicated cone beam breast CT using a forward-projection model. Med Phys 2017;44:2312-2320. [PMID: 28295375 DOI: 10.1002/mp.12213] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2016] [Revised: 01/25/2017] [Accepted: 03/07/2017] [Indexed: 12/25/2022]  Open
Number Cited by Other Article(s)
1
Tseng HW, Fu Z, Vedantham S. Simultaneous reduction of radiation dose and scatter-to-primary ratio using a truncated detector and advanced algorithms for dedicated cone-beam breast CT. Biomed Phys Eng Express 2025;11:025047. [PMID: 39983239 PMCID: PMC12047646 DOI: 10.1088/2057-1976/adb8f1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2024] [Revised: 02/13/2025] [Accepted: 02/21/2025] [Indexed: 02/23/2025]
2
Shi L, Bennett NR, Vezeridis A, Kothary N, Wang AS. Single-shot quantitative x-ray imaging using a primary modulator and dual-layer detector. Med Phys 2024;51:2621-2632. [PMID: 37843975 PMCID: PMC11005317 DOI: 10.1002/mp.16789] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Revised: 06/20/2023] [Accepted: 10/01/2023] [Indexed: 10/18/2023]  Open
3
Pautasso JJ, Caballo M, Mikerov M, Boone JM, Michielsen K, Sechopoulos I. Deep learning for x-ray scatter correction in dedicated breast CT. Med Phys 2022;50:2022-2036. [PMID: 36565012 DOI: 10.1002/mp.16185] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2022] [Revised: 12/12/2022] [Accepted: 12/12/2022] [Indexed: 12/25/2022]  Open
4
Tseng HW, Karellas A, Vedantham S. Cone-beam breast CT using an offset detector: effect of detector offset and image reconstruction algorithm. Phys Med Biol 2022;67. [PMID: 35316793 PMCID: PMC9045275 DOI: 10.1088/1361-6560/ac5fe1] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Accepted: 03/22/2022] [Indexed: 11/12/2022]
5
Paganetti H, Botas P, Sharp GC, Winey B. Adaptive proton therapy. Phys Med Biol 2021;66:10.1088/1361-6560/ac344f. [PMID: 34710858 PMCID: PMC8628198 DOI: 10.1088/1361-6560/ac344f] [Citation(s) in RCA: 64] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2021] [Accepted: 10/28/2021] [Indexed: 12/25/2022]
6
Fahrig R, Jaffray DA, Sechopoulos I, Webster Stayman J. Flat-panel conebeam CT in the clinic: history and current state. J Med Imaging (Bellingham) 2021;8:052115. [PMID: 34722795 DOI: 10.1117/1.jmi.8.5.052115] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Accepted: 09/27/2021] [Indexed: 11/14/2022]  Open
7
Tseng HW, Karellas A, Vedantham S. Radiation dosimetry of a clinical prototype dedicated cone-beam breast CT system with offset detector. Med Phys 2021;48:1079-1088. [PMID: 33501686 DOI: 10.1002/mp.14688] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2020] [Revised: 12/15/2020] [Accepted: 12/17/2020] [Indexed: 12/27/2022]  Open
8
Tseng HW, Karellas A, Vedantham S. Optical conductivity of triple point fermions. JOURNAL OF PHYSICS. CONDENSED MATTER : AN INSTITUTE OF PHYSICS JOURNAL 2021;33:10.1088/2057-1976/abb834. [PMID: 33373981 PMCID: PMC8004539 DOI: 10.1088/1361-648x/abd739] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Accepted: 12/29/2020] [Indexed: 01/12/2023]
9
Fu Z, Tseng HW, Vedantham S, Karellas A, Bilgin A. A residual dense network assisted sparse view reconstruction for breast computed tomography. Sci Rep 2020;10:21111. [PMID: 33273541 PMCID: PMC7713379 DOI: 10.1038/s41598-020-77923-0] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Accepted: 11/18/2020] [Indexed: 12/24/2022]  Open
10
Tseng HW, Karellas A, Vedantham S. Sparse-view, short-scan, dedicated cone-beam breast computed tomography: image quality assessment. Biomed Phys Eng Express 2020;6:10.1088/2057-1976/abb834. [PMID: 33377758 PMCID: PMC8004539 DOI: 10.1088/2057-1976/abb834] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Accepted: 09/14/2020] [Indexed: 01/01/2023]
11
Tseng HW, Vedantham S, Karellas A. Cone-beam breast computed tomography using ultra-fast image reconstruction with constrained, total-variation minimization for suppression of artifacts. Phys Med 2020;73:117-124. [PMID: 32361156 DOI: 10.1016/j.ejmp.2020.04.020] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/12/2019] [Revised: 03/31/2020] [Accepted: 04/21/2020] [Indexed: 12/18/2022]  Open
12
Vedantham S, Tseng HW, Konate S, Shi L, Karellas A. Dedicated cone-beam breast CT using laterally-shifted detector geometry: Quantitative analysis of feasibility for clinical translation. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2020;28:405-426. [PMID: 32333575 PMCID: PMC7347391 DOI: 10.3233/xst-200651] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
13
Liang X, Li N, Zhang Z, Yu S, Qin W, Li Y, Chen S, Zhang H, Xie Y. Shading correction for volumetric CT using deep convolutional neural network and adaptive filter. Quant Imaging Med Surg 2019;9:1242-1254. [PMID: 31448210 PMCID: PMC6685805 DOI: 10.21037/qims.2019.05.19] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2019] [Accepted: 05/15/2019] [Indexed: 01/17/2023]
14
Liang X, Jiang Y, Zhao W, Zhang Z, Luo C, Xiong J, Yu S, Yang X, Sun J, Zhou Q, Niu T, Xie Y. Scatter correction for a clinical cone‐beam CT system using an optimized stationary beam blocker in a single scan. Med Phys 2019;46:3165-3179. [DOI: 10.1002/mp.13568] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2018] [Revised: 04/04/2019] [Accepted: 04/25/2019] [Indexed: 12/16/2022]  Open
15
Shi L, Wang A, Wei J, Zhu L. Fast shading correction for cone-beam CT via partitioned tissue classification. Phys Med Biol 2019;64:065015. [PMID: 30721886 DOI: 10.1088/1361-6560/ab0475] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
16
Hashemi S, Huynh C, Sahgal A, Song WY, Nordström H, Eriksson M, Mainprize JG, Lee Y, Ruschin M. Cone-Beam CT image contrast and attenuation-map linearity improvement (CALI) for brain stereotactic radiosurgery procedures. J Appl Clin Med Phys 2018;19:200-208. [PMID: 30338919 PMCID: PMC6236823 DOI: 10.1002/acm2.12477] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2018] [Revised: 09/19/2018] [Accepted: 09/24/2018] [Indexed: 11/11/2022]  Open
17
Zhao W, Vernekohl D, Han F, Han B, Peng H, Yang Y, Xing L, Min JK. A unified material decomposition framework for quantitative dual‐ and triple‐energy CT imaging. Med Phys 2018;45:2964-2977. [DOI: 10.1002/mp.12933] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2017] [Revised: 01/26/2018] [Accepted: 02/25/2018] [Indexed: 12/16/2022]  Open
18
Vedantham S, Karellas A. Emerging Breast Imaging Technologies on the Horizon. Semin Ultrasound CT MR 2018;39:114-121. [PMID: 29317033 DOI: 10.1053/j.sult.2017.09.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
19
Shi L, Vedantham S, Karellas A, Zhu L. The role of off-focus radiation in scatter correction for dedicated cone beam breast CT. Med Phys 2017;45:191-201. [PMID: 29159941 DOI: 10.1002/mp.12686] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2017] [Revised: 11/02/2017] [Accepted: 11/12/2017] [Indexed: 12/18/2022]  Open
PrevPage 1 of 1 1Next
© 2004-2025 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA