1
|
Tseng HW, Fu Z, Vedantham S. Simultaneous reduction of radiation dose and scatter-to-primary ratio using a truncated detector and advanced algorithms for dedicated cone-beam breast CT. Biomed Phys Eng Express 2025; 11:025047. [PMID: 39983239 PMCID: PMC12047646 DOI: 10.1088/2057-1976/adb8f1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2024] [Revised: 02/13/2025] [Accepted: 02/21/2025] [Indexed: 02/23/2025]
Abstract
Objective. To determine the minimum detector width along the fan-angle direction in offset-detector cone-beam breast CT for multiple advanced reconstruction algorithms and to investigate the effect on radiation dose, scatter, and image quality.Approach.Complete sinograms (m×n= 1024 × 768 pixels) of 30 clinical breast CT datasets previously acquired on a clinical-prototype cone-beam breast CT system were reconstructed using Feldkamp-Davis-Kress (FDK) algorithm and served as the reference. Complete sinograms were retrospectively truncated to varying widths to understand the limits of four image reconstruction algorithms-FDK with redundancy weighting (FDK-W), compressed-sensing based FRIST, fully-supervised MS-RDN, and self-supervised AFN. Upon determining the truncation limits, numerical phantoms generated by segmenting the reference reconstructions into skin, adipose, and fibroglandular tissues were used to determine the radiation dose and scatter-to-primary ratio (SPR) using Monte Carlo simulations.Main results.FDK-W, FRIST, and MS-RDN showed artifacts whenm< 596, whereas AFN reconstructed images without artifacts form> = 536. Reducing the detector width reduced signal-difference to noise ratio (SDNR) for FDK-W, whereas FRIST, MS-RDN and AFN maintained or improved SDNR. Reference reconstruction and AFN withm= 536 had similar quantitative measures of image quality.Significance.For the 30 cases, AFN withm= 536 reduced the radiation dose and SPR by 37.85% and 33.46%, respectively, compared to the reference. Qualitative and quantitative image quality indicate the feasibility of AFN for offset-detector cone-beam breast CT. Radiation dose and SPR were simultaneously reduced with a 536 × 768 detector and when used in conjunction with AFN algorithm had similar image quality as the reference reconstruction.
Collapse
Affiliation(s)
- Hsin Wu Tseng
- Department of Medical Imaging, The University of Arizona, Tucson, AZ, United States of America
| | - Zhiyang Fu
- Department of Medical Imaging, The University of Arizona, Tucson, AZ, United States of America
| | - Srinivasan Vedantham
- Department of Medical Imaging, The University of Arizona, Tucson, AZ, United States of America
- Department of Biomedical Engineering, The University of Arizona, Tucson, AZ, United States of America
| |
Collapse
|
2
|
Shi L, Bennett NR, Vezeridis A, Kothary N, Wang AS. Single-shot quantitative x-ray imaging using a primary modulator and dual-layer detector. Med Phys 2024; 51:2621-2632. [PMID: 37843975 PMCID: PMC11005317 DOI: 10.1002/mp.16789] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Revised: 06/20/2023] [Accepted: 10/01/2023] [Indexed: 10/18/2023] Open
Abstract
BACKGROUND Conventional x-ray imaging and fluoroscopy have limitations in quantitation due to several challenges, including scatter, beam hardening, and overlapping tissues. Dual-energy (DE) imaging, with its capability to quantify area density of specific materials, is well-suited to address such limitations, but only if the dual-energy projections are acquired with perfect spatial and temporal alignment and corrected for scatter. PURPOSE In this work, we propose single-shot quantitative imaging (SSQI) by combining the use of a primary modulator (PM) and dual-layer (DL) detector, which enables motion-free DE imaging with scatter correction in a single exposure. METHODS The key components of our SSQI setup include a PM and DL detector, where the former enables scatter correction for the latter while the latter enables beam hardening correction for the former. The SSQI algorithm allows simultaneous recovery of two material-specific images and two scatter images using four sub-measurements from the PM encoding. The concept was first demonstrated using simulation of chest x-ray imaging for a COVID patient. For validation, we set up SSQI geometry on our tabletop system and imaged acrylic and copper slabs with known thicknesses (acrylic: 0-22.5 cm; copper: 0-0.9 mm), estimated scatter with our SSQI algorithm, and compared the material decomposition (MD) for different combinations of the two materials with ground truth. Second, we imaged an anthropomorphic chest phantom containing contrast in the coronary arteries and compared the MD with and without SSQI. Lastly, to evaluate SSQI in dynamic applications, we constructed a flow phantom that enabled dynamic imaging of iodine contrast. RESULTS Our simulation study demonstrated that SSQI led to accurate scatter correction and MD, particularly for smaller focal blur and finer PM pitch. In the validation study, we found that the root mean squared error (RMSE) of SSQI estimation was 0.13 cm for acrylic and 0.04 mm for copper. For the anthropomorphic phantom, direct MD resulted in incorrect interpretation of contrast and soft tissue, while SSQI successfully distinguished them quantitatively, reducing RMSE in material-specific images by 38%-92%. For the flow phantom, SSQI was able to perform accurate dynamic quantitative imaging, separating contrast from the background. CONCLUSIONS We demonstrated the potential of SSQI for robust quantitative x-ray imaging. The integration of SSQI is straightforward with the addition of a PM and upgrade to a DL detector, which may enable its widespread adoption, including in techniques such as radiography and dynamic imaging (i.e., real-time image guidance and cone-beam CT).
Collapse
Affiliation(s)
- Linxi Shi
- Department of Radiology, Stanford University, Stanford, California, USA
| | | | | | - Nishita Kothary
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Adam S Wang
- Department of Radiology, Stanford University, Stanford, California, USA
| |
Collapse
|
3
|
Pautasso JJ, Caballo M, Mikerov M, Boone JM, Michielsen K, Sechopoulos I. Deep learning for x-ray scatter correction in dedicated breast CT. Med Phys 2022; 50:2022-2036. [PMID: 36565012 DOI: 10.1002/mp.16185] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2022] [Revised: 12/12/2022] [Accepted: 12/12/2022] [Indexed: 12/25/2022] Open
Abstract
BACKGROUND Accurate correction of x-ray scatter in dedicated breast computed tomography (bCT) imaging may result in improved visual interpretation and is crucial to achieve quantitative accuracy during image reconstruction and analysis. PURPOSE To develop a deep learning (DL) model to correct for x-ray scatter in bCT projection images. METHODS A total of 115 patient scans acquired with a bCT clinical system were segmented into the major breast tissue types (skin, adipose, and fibroglandular tissue). The resulting breast phantoms were divided into training (n = 110) and internal validation cohort (n = 5). Training phantoms were augmented by a factor of four by random translation of the breast in the image field of view. Using a previously validated Monte Carlo (MC) simulation algorithm, 12 primary and scatter bCT projection images with a 30-degree step were generated from each phantom. For each projection, the thickness map and breast location in the field of view were also calculated. A U-Net based DL model was developed to estimate the scatter signal based on the total input simulated image and trained single-projection-wise, with the thickness map and breast location provided as additional inputs. The model was internally validated using MC-simulated projections and tested using an external data set of 10 phantoms derived from images acquired with a different bCT system. For this purpose, the mean relative difference (MRD) and mean absolute error (MAE) were calculated. To test for accuracy in reconstructed images, a full bCT acquisition was mimicked with MC-simulations and then assessed by calculating the MAE and the structural similarity (SSIM). Subsequently, scatter was estimated and subtracted from the bCT scans of three patients to obtain the scatter-corrected image. The scatter-corrected projections were reconstructed and compared with the uncorrected reconstructions by evaluating the correction of the cupping artifact, increase in image contrast, and contrast-to-noise ratio (CNR). RESULTS The mean MRD and MAE across all cases (min, max) for the internal validation set were 0.04% (-1.1%, 1.3%) and 2.94% (2.7%, 3.2%), while for the external test set they were -0.64% (-1.6%, 0.2%) and 2.84% (2.3%, 3.5%), respectively. For MC-simulated reconstruction slices, the computed SSIM was 0.99 and the MAE was 0.11% (range: 0%, 0.35%) with a single outlier slice of 2.06%. For the three patient bCT reconstructed images, the correction increased the contrast by a mean of 25% (range: 20%, 30%), and reduced the cupping artifact. The mean CNR increased by 0.32 after scatter correction, which was not found to be significant (95% confidence interval: [-0.01, 0.65], p = 0.059). The time required to correct the scatter in a single bCT projection was 0.2 s on an NVIDIA GeForce GTX 1080 GPU. CONCLUSION The developed DL model could accurately estimate scatter in bCT projection images and could enhance contrast and correct for cupping artifact in reconstructed patient images without significantly affecting the CNR. The time required for correction would allow its use in daily clinical practice, and the reported accuracy will potentially allow quantitative reconstructions.
Collapse
Affiliation(s)
- Juan J Pautasso
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Marco Caballo
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Mikhail Mikerov
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands
| | - John M Boone
- Department of Radiology, University of California Davis, Sacramento, California, USA.,Department of Biomedical Engineering, University of California Davis, Sacramento, California, USA
| | - Koen Michielsen
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Ioannis Sechopoulos
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands.,Dutch Expert Centre for Screening (LRCB), Nijmegen, The Netherlands.,Technical Medical Centre, University of Twente, Enschede, The Netherlands
| |
Collapse
|
4
|
Tseng HW, Karellas A, Vedantham S. Cone-beam breast CT using an offset detector: effect of detector offset and image reconstruction algorithm. Phys Med Biol 2022; 67. [PMID: 35316793 PMCID: PMC9045275 DOI: 10.1088/1361-6560/ac5fe1] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Accepted: 03/22/2022] [Indexed: 11/12/2022]
Abstract
Objective.A dedicated cone-beam breast computed tomography (BCT) using a high-resolution, low-noise detector operating in offset-detector geometry has been developed. This study investigates the effects of varying detector offsets and image reconstruction algorithms to determine the appropriate combination of detector offset and reconstruction algorithm.Approach.Projection datasets (300 projections in 360°) of 30 breasts containing calcified lesions that were acquired using a prototype cone-beam BCT system comprising a 40 × 30 cm flat-panel detector with 1024 × 768 detector pixels were reconstructed using Feldkamp-Davis-Kress (FDK) algorithm and served as the reference. The projection datasets were retrospectively truncated to emulate cone-beam datasets with sinograms of 768×768 and 640×768 detector pixels, corresponding to 5 cm and 7.5 cm lateral offsets, respectively. These datasets were reconstructed using the FDK algorithm with appropriate weights and an ASD-POCS-based Fast, total variation-Regularized, Iterative, Statistical reconstruction Technique (FRIST), resulting in a total of 4 offset-detector reconstructions (2 detector offsets × 2 reconstruction methods). Signal difference-to-noise ratio (SDNR), variance, and full-width at half-maximum (FWHM) of calcifications in two orthogonal directions were determined from all reconstructions. All quantitative measurements were performed on images in units of linear attenuation coefficient (1/cm).Results.The FWHM of calcifications did not differ (P > 0.262) among reconstruction algorithms and detector formats, implying comparable spatial resolution. For a chosen detector offset, the FRIST algorithm outperformed FDK in terms of variance and SDNR (P < 0.0001). For a given reconstruction method, the 5 cm offset provided better results.Significance.This study indicates the feasibility of using the compressed sensing-based, FRIST algorithm to reconstruct sinograms from offset-detectors. Among the reconstruction methods and detector offsets studied, FRIST reconstructions corresponding to a 30 cm × 30 cm with 5 cm lateral offset, achieved the best performance. A clinical prototype using such an offset geometry has been developed and installed for clinical trials.
Collapse
Affiliation(s)
- Hsin Wu Tseng
- Department of Medical Imaging, The University of Arizona, Tucson, AZ, United States of America
| | - Andrew Karellas
- Department of Medical Imaging, The University of Arizona, Tucson, AZ, United States of America
| | - Srinivasan Vedantham
- Department of Medical Imaging, The University of Arizona, Tucson, AZ, United States of America.,Department of Biomedical Engineering, The University of Arizona, Tucson, AZ, United States of America
| |
Collapse
|
5
|
Paganetti H, Botas P, Sharp GC, Winey B. Adaptive proton therapy. Phys Med Biol 2021; 66:10.1088/1361-6560/ac344f. [PMID: 34710858 PMCID: PMC8628198 DOI: 10.1088/1361-6560/ac344f] [Citation(s) in RCA: 64] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2021] [Accepted: 10/28/2021] [Indexed: 12/25/2022]
Abstract
Radiation therapy treatments are typically planned based on a single image set, assuming that the patient's anatomy and its position relative to the delivery system remains constant during the course of treatment. Similarly, the prescription dose assumes constant biological dose-response over the treatment course. However, variations can and do occur on multiple time scales. For treatment sites with significant intra-fractional motion, geometric changes happen over seconds or minutes, while biological considerations change over days or weeks. At an intermediate timescale, geometric changes occur between daily treatment fractions. Adaptive radiation therapy is applied to consider changes in patient anatomy during the course of fractionated treatment delivery. While traditionally adaptation has been done off-line with replanning based on new CT images, online treatment adaptation based on on-board imaging has gained momentum in recent years due to advanced imaging techniques combined with treatment delivery systems. Adaptation is particularly important in proton therapy where small changes in patient anatomy can lead to significant dose perturbations due to the dose conformality and finite range of proton beams. This review summarizes the current state-of-the-art of on-line adaptive proton therapy and identifies areas requiring further research.
Collapse
Affiliation(s)
- Harald Paganetti
- Department of Radiation Oncology, Physics Division, Massachusetts General Hospital, Boston, Massachusetts, United States of America
- Harvard Medical School, Boston, Massachusetts, United States of America
| | - Pablo Botas
- Department of Radiation Oncology, Physics Division, Massachusetts General Hospital, Boston, Massachusetts, United States of America
- Harvard Medical School, Boston, Massachusetts, United States of America
- Foundation 29 of February, Pozuelo de Alarcón, Madrid, Spain
| | - Gregory C Sharp
- Department of Radiation Oncology, Physics Division, Massachusetts General Hospital, Boston, Massachusetts, United States of America
- Harvard Medical School, Boston, Massachusetts, United States of America
| | - Brian Winey
- Department of Radiation Oncology, Physics Division, Massachusetts General Hospital, Boston, Massachusetts, United States of America
- Harvard Medical School, Boston, Massachusetts, United States of America
| |
Collapse
|
6
|
Fahrig R, Jaffray DA, Sechopoulos I, Webster Stayman J. Flat-panel conebeam CT in the clinic: history and current state. J Med Imaging (Bellingham) 2021; 8:052115. [PMID: 34722795 DOI: 10.1117/1.jmi.8.5.052115] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Accepted: 09/27/2021] [Indexed: 11/14/2022] Open
Abstract
Research into conebeam CT concepts began as soon as the first clinical single-slice CT scanner was conceived. Early implementations of conebeam CT in the 1980s focused on high-contrast applications where concurrent high resolution ( < 200 μ m ), for visualization of small contrast-filled vessels, bones, or teeth, was an imaging requirement that could not be met by the contemporaneous CT scanners. However, the use of nonlinear imagers, e.g., x-ray image intensifiers, limited the clinical utility of the earliest diagnostic conebeam CT systems. The development of consumer-electronics large-area displays provided a technical foundation that was leveraged in the 1990s to first produce large-area digital x-ray detectors for use in radiography and then compact flat panels suitable for high-resolution and high-frame-rate conebeam CT. In this review, we show the concurrent evolution of digital flat panel (DFP) technology and clinical conebeam CT. We give a brief summary of conebeam CT reconstruction, followed by a brief review of the correction approaches for DFP-specific artifacts. The historical development and current status of flat-panel conebeam CT in four clinical areas-breast, fixed C-arm, image-guided radiation therapy, and extremity/head-is presented. Advances in DFP technology over the past two decades have led to improved visualization of high-contrast, high-resolution clinical tasks, and image quality now approaches the soft-tissue contrast resolution that is the standard in clinical CT. Future technical developments in DFPs will enable an even broader range of clinical applications; research in the arena of flat-panel CT shows no signs of slowing down.
Collapse
Affiliation(s)
- Rebecca Fahrig
- Innovation, Advanced Therapies, Siemens Healthcare GmbH, Forchheim, Germany.,Friedrich-Alexander Universitat, Department of Computer Science 5, Erlangen, Germany
| | - David A Jaffray
- MD Anderson Cancer Center, Departments of Radiation Physics and Imaging Physics, Houston, Texas, United States
| | - Ioannis Sechopoulos
- Radboud University Medical Center, Department of Medical Imaging, Nijmegen, The Netherlands.,Dutch Expert Center for Screening (LRCB), Nijmegen, The Netherlands.,University of Twente, Technical Medical Center, Enschede, The Netherlands
| | - J Webster Stayman
- Johns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States
| |
Collapse
|
7
|
Tseng HW, Karellas A, Vedantham S. Radiation dosimetry of a clinical prototype dedicated cone-beam breast CT system with offset detector. Med Phys 2021; 48:1079-1088. [PMID: 33501686 DOI: 10.1002/mp.14688] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2020] [Revised: 12/15/2020] [Accepted: 12/17/2020] [Indexed: 12/27/2022] Open
Abstract
PURPOSE A clinical-prototype, dedicated, cone-beam breast computed tomography (CBBCT) system with offset detector is undergoing clinical evaluation at our institution. This study is to estimate the normalized glandular dose coefficients ( DgN CT ) that provide air kerma-to-mean glandular dose conversion factors using Monte Carlo simulations. MATERIALS AND METHODS The clinical prototype CBBCT system uses 49 kV x-ray spectrum with 1.39 mm 1st half-value layer thickness. Monte Carlo simulations (GATE, version 8) were performed with semi-ellipsoidal, homogeneous breasts of various fibroglandular weight fractions ( f g = 0.01 , 0.15 , 0.5 , 1 ) , chest wall diameters ( d = 8 , 10 , 14 , 18 , 20 cm), and chest wall to nipple length ( l = 0.75 d ), aligned with the axis of rotation (AOR) located at 65 cm from the focal spot to determine the DgN CT . Three geometries were considered - 40 × 30 -cm detector with no offset that served as reference and corresponds to a clinical CBBCT system, 30 × 30 -cm detector with 5 cm offset, and a 30 × 30 -cm detector with 10 cm offset. RESULTS For 5 cm lateral offset, the DgN CT ranged 0.177 - 0.574 mGy/mGy and reduction in DgN CT with respect to reference geometry was observed only for 18 cm ( 6.4 % ± 0.23 % ) and 20 cm ( 9.6 % ± 0.22 % ) diameter breasts. For the 10 cm lateral offset, the DgN CT ranged 0.221 - 0.581 mGy/mGy and reduction in DgN CT was observed for all breast diameters. The reduction in DgN CT was 1.4 % ± 0.48 % , 7.1 % ± 0.13 % , 17.5 % ± 0.19 % , 25.1 % ± 0.15 % , and 27.7 % ± 0.08 % for 8, 10, 14, 18, and 20 cm diameter breasts, respectively. For a given breast diameter, the reduction in DgN CT with offset-detector geometries was not dependent on f g . Numerical fits of DgN CT d , l , f g were generated for each geometry. CONCLUSION The DgN CT and the numerical fit, D g N CT d , l , f g would be of benefit for current CBBCT systems using the reference geometry and for future generations using offset-detector geometry. There exists a potential for radiation dose reduction with offset-detector geometry, provided the same technique factors as the reference geometry are used, and the image quality is clinically acceptable.
Collapse
Affiliation(s)
- Hsin Wu Tseng
- Department of Medical Imaging, The University of Arizona, Tucson, AZ, USA
| | - Andrew Karellas
- Department of Medical Imaging, The University of Arizona, Tucson, AZ, USA
| | - Srinivasan Vedantham
- Department of Medical Imaging, The University of Arizona, Tucson, AZ, USA.,Department of Biomedical Engineering, The University of Arizona, Tucson, AZ, USA
| |
Collapse
|
8
|
Tseng HW, Karellas A, Vedantham S. Optical conductivity of triple point fermions. JOURNAL OF PHYSICS. CONDENSED MATTER : AN INSTITUTE OF PHYSICS JOURNAL 2021; 33:10.1088/2057-1976/abb834. [PMID: 33373981 PMCID: PMC8004539 DOI: 10.1088/1361-648x/abd739] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Accepted: 12/29/2020] [Indexed: 01/12/2023]
Abstract
As a low-energy effective theory on non-symmorphic lattices, we consider a generic triple point fermion Hamiltonian, which is parameterized by an angular parameterλ. We find strongλdependence in both Drude and interband optical absorption of these systems. The deviation of theT2coefficient of the Drude weight from Dirac/Weyl fermions can be used as a quick way to optically distinguish the triple point degeneracies from the Dirac/Weyl degeneracies. At the particularλ=π/6 point, we find that the 'helicity' reversal optical transition matrix element is identically zero. Nevertheless, deviating from this point, the helicity reversal emerges as an absorption channel.
Collapse
Affiliation(s)
- Hsin Wu Tseng
- Department of Medical Imaging, The University of Arizona, Tucson, AZ
| | - Andrew Karellas
- Department of Medical Imaging, The University of Arizona, Tucson, AZ
| | - Srinivasan Vedantham
- Department of Medical Imaging, The University of Arizona, Tucson, AZ
- Department of Biomedical Engineering, The University of Arizona, Tucson, AZ
| |
Collapse
|
9
|
Fu Z, Tseng HW, Vedantham S, Karellas A, Bilgin A. A residual dense network assisted sparse view reconstruction for breast computed tomography. Sci Rep 2020; 10:21111. [PMID: 33273541 PMCID: PMC7713379 DOI: 10.1038/s41598-020-77923-0] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Accepted: 11/18/2020] [Indexed: 12/24/2022] Open
Abstract
To develop and investigate a deep learning approach that uses sparse-view acquisition in dedicated breast computed tomography for radiation dose reduction, we propose a framework that combines 3D sparse-view cone-beam acquisition with a multi-slice residual dense network (MS-RDN) reconstruction. Projection datasets (300 views, full-scan) from 34 women were reconstructed using the FDK algorithm and served as reference. Sparse-view (100 views, full-scan) projection data were reconstructed using the FDK algorithm. The proposed MS-RDN uses the sparse-view and reference FDK reconstructions as input and label, respectively. Our MS-RDN evaluated with respect to fully sampled FDK reference yields superior performance, quantitatively and visually, compared to conventional compressed sensing methods and state-of-the-art deep learning based methods. The proposed deep learning driven framework can potentially enable low dose breast CT imaging.
Collapse
Affiliation(s)
- Zhiyang Fu
- Department of Medical Imaging, University of Arizona, Tucson, AZ, USA.,Department of Electrical and Computer Engineering, University of Arizona, Tucson, AZ, USA
| | - Hsin Wu Tseng
- Department of Medical Imaging, University of Arizona, Tucson, AZ, USA
| | - Srinivasan Vedantham
- Department of Medical Imaging, University of Arizona, Tucson, AZ, USA.,Department of Biomedical Engineering, University of Arizona, Tucson, AZ, USA
| | - Andrew Karellas
- Department of Medical Imaging, University of Arizona, Tucson, AZ, USA
| | - Ali Bilgin
- Department of Medical Imaging, University of Arizona, Tucson, AZ, USA. .,Department of Electrical and Computer Engineering, University of Arizona, Tucson, AZ, USA. .,Department of Biomedical Engineering, University of Arizona, Tucson, AZ, USA.
| |
Collapse
|
10
|
Tseng HW, Karellas A, Vedantham S. Sparse-view, short-scan, dedicated cone-beam breast computed tomography: image quality assessment. Biomed Phys Eng Express 2020; 6:10.1088/2057-1976/abb834. [PMID: 33377758 PMCID: PMC8004539 DOI: 10.1088/2057-1976/abb834] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Accepted: 09/14/2020] [Indexed: 01/01/2023]
Abstract
The purpose of this study is to quantify the impact of sparse-view acquisition in short-scan trajectories, compared to 360-degrees full-scan acquisition, on image quality measures in dedicated cone-beam breast computed tomography (BCT). Projection data from 30 full-scan (360-degrees; 300 views) BCT exams with calcified lesions were selected from an existing clinical research database. Feldkamp-Davis-Kress (FDK) reconstruction of the full-scan data served as the reference. Projection data corresponding to two short-scan trajectories, 204 and 270-degrees, which correspond to the minimum and maximum angular range achievable in a cone-beam BCT system were selected. Projection data were retrospectively sampled to provide 225, 180, and 168 views for 270-degrees short-scan, and 170 views for 204-degrees short-scan. Short-scans with 180 and 168 views in 270-degrees used non-uniform angular sampling. A fast, iterative, total variation-regularized, statistical reconstruction technique (FIRST) was used for short-scan image reconstruction. Image quality was quantified by variance, signal-difference to noise ratio (SDNR) between adipose and fibroglandular tissues, full-width at half-maximum (FWHM) of calcifications in two orthogonal directions, as well as, bias and root-mean-squared-error (RMSE) computed with respect to the reference full-scan FDK reconstruction. The median values of bias (8.6 × 10-4-10.3 × 10-4cm-1) and RMSE (6.8 × 10-6-9.8 × 10-6cm-1) in the short-scan reconstructions, computed with the full-scan FDK as the reference were close to, but not zero (P < 0.0001, one-sample median test). The FWHM of the calcifications in the short-scan reconstructions did not differ significantly from the reference FDK reconstruction (P > 0.118), except along the superior-inferior direction for the short-scan reconstruction with 168 views in 270-degrees (P = 0.046). The variance and SDNR from short-scan reconstructions were significantly improved compared to the full-scan FDK reconstruction (P < 0.0001). This study demonstrates the feasibility of the short-scan, sparse-view, compressed sensing-based iterative reconstruction. This study indicates that shorter scan times and reduced radiation dose without sacrificing image quality are potentially feasible.
Collapse
Affiliation(s)
- Hsin Wu Tseng
- Department of Medical Imaging, The University of Arizona, Tucson, AZ
| | - Andrew Karellas
- Department of Medical Imaging, The University of Arizona, Tucson, AZ
| | - Srinivasan Vedantham
- Department of Medical Imaging, The University of Arizona, Tucson, AZ
- Department of Biomedical Engineering, The University of Arizona, Tucson, AZ
| |
Collapse
|
11
|
Tseng HW, Vedantham S, Karellas A. Cone-beam breast computed tomography using ultra-fast image reconstruction with constrained, total-variation minimization for suppression of artifacts. Phys Med 2020; 73:117-124. [PMID: 32361156 DOI: 10.1016/j.ejmp.2020.04.020] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/12/2019] [Revised: 03/31/2020] [Accepted: 04/21/2020] [Indexed: 12/18/2022] Open
Abstract
Compressed sensing based iterative reconstruction algorithms for computed tomography such as adaptive steepest descent-projection on convex sets (ASD-POCS) are attractive due to their applicability in incomplete datasets such as sparse-view data and can reduce radiation dose to the patients while preserving image quality. Although IR algorithms reduce image noise compared to analytical Feldkamp-Davis-Kress (FDK) algorithm, they may generate artifacts, particularly along the periphery of the object. One popular solution is to use finer image-grid followed by down-sampling. This approach is computationally intensive but may be compensated by reducing the field of view. Our proposed solution is to replace the algebraic reconstruction technique within the original ASD-POCS by ordered subsets-simultaneous algebraic reconstruction technique (OS-SART) and with initialization using FDK image. We refer to this method as Fast, Iterative, TV-Regularized, Statistical reconstruction Technique (FIRST). In this study, we investigate FIRST for cone-beam dedicated breast CT with large image matrix. The signal-difference to noise ratio (SDNR), the difference of the mean value and the variance of adipose and fibroglandular tissues for both FDK and FIRST reconstructions were determined. With FDK serving as the reference, the root-mean-square error (RMSE), bias, and the full-width at half-maximum (FWHM) of microcalcifications in two orthogonal directions were also computed. Our results suggest that FIRST is competitive to the finer image-grid method with shorter reconstruction time. Images reconstructed using the FIRST do not exhibit artifacts and outperformed FDK in terms of image noise. This suggests the potential of this approach for radiation dose reduction in cone-beam breast CT.
Collapse
Affiliation(s)
- Hsin Wu Tseng
- Department of Medical Imaging, University of Arizona, Tucson, AZ 85724, United States
| | - Srinivasan Vedantham
- Department of Medical Imaging, University of Arizona, Tucson, AZ 85724, United States; Department of Biomedical Engineering, University of Arizona, Tucson, AZ 85724, United States
| | - Andrew Karellas
- Department of Medical Imaging, University of Arizona, Tucson, AZ 85724, United States.
| |
Collapse
|
12
|
Vedantham S, Tseng HW, Konate S, Shi L, Karellas A. Dedicated cone-beam breast CT using laterally-shifted detector geometry: Quantitative analysis of feasibility for clinical translation. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2020; 28:405-426. [PMID: 32333575 PMCID: PMC7347391 DOI: 10.3233/xst-200651] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
BACKGROUND High-resolution, low-noise detectors with minimal dead-space at chest-wall could improve posterior coverage and microcalcification visibility in the dedicated cone-beam breast CT (CBBCT). However, the smaller field-of-view necessitates laterally-shifted detector geometry to enable optimizing the air-gap for x-ray scatter rejection. OBJECTIVE To evaluate laterally-shifted detector geometry for CBBCT with clinical projection datasets that provide for anatomical structures and lesions. METHODS CBBCT projection datasets (n = 17 breasts) acquired with a 40×30 cm detector (1024×768-pixels, 0.388-mm pixels) were truncated along the fan-angle to emulate 20.3×30 cm, 22.2×30 cm and 24.1×30 cm detector formats and correspond to 20, 120, 220 pixels overlap in conjugate views, respectively. Feldkamp-Davis-Kress (FDK) algorithm with 3 different weighting schemes were used for reconstruction. Visual analysis for artifacts and quantitative analysis of root-mean-squared-error (RMSE), absolute difference between truncated and 40×30 cm reconstructions (Diff), and its power spectrum (PSDiff) were performed. RESULTS Artifacts were observed for 20.3×30 cm, but not for other formats. The 24.1×30 cm provided the best quantitative results with RMSE and Diff (both in units of μ, cm-1) of 4.39×10-3±1.98×10-3 and 4.95×10-4±1.34×10-4, respectively. The PSDiff (>0.3 cycles/mm) was in the order of 10-14μ2mm3 and was spatial-frequency independent. CONCLUSIONS Laterally-shifted detector CBBCT with at least 220 pixels overlap in conjugate views (24.1×30 cm detector format) provides quantitatively accurate and artifact-free image reconstruction.
Collapse
Affiliation(s)
- Srinivasan Vedantham
- Department of Medical Imaging, University of Arizona, Tucson, AZ 85724
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ 85724
| | - Hsin-Wu Tseng
- Department of Medical Imaging, University of Arizona, Tucson, AZ 85724
| | - Souleymane Konate
- Harvard T.H. Chan School of Public Health, Harvard University, Boston, MA 02115
| | - Linxi Shi
- Department of Radiology, Stanford University, Stanford, CA 94305
| | - Andrew Karellas
- Department of Medical Imaging, University of Arizona, Tucson, AZ 85724
| |
Collapse
|
13
|
Liang X, Li N, Zhang Z, Yu S, Qin W, Li Y, Chen S, Zhang H, Xie Y. Shading correction for volumetric CT using deep convolutional neural network and adaptive filter. Quant Imaging Med Surg 2019; 9:1242-1254. [PMID: 31448210 PMCID: PMC6685805 DOI: 10.21037/qims.2019.05.19] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2019] [Accepted: 05/15/2019] [Indexed: 01/17/2023]
Abstract
BACKGROUND Shading artifact may lead to CT number inaccuracy, image contrast loss and spatial non-uniformity (SNU), which is considered as one of the fundamental limitations for volumetric CT (VCT) application. To correct the shading artifact, a novel approach is proposed using deep learning and an adaptive filter (AF). METHODS Firstly, we apply the deep convolutional neural network (DCNN) to train a human tissue segmentation model. The trained model is implemented to segment the tissue. According to the general knowledge that CT number of the same human tissue is approximately the same, a template image without shading artifact can be generated using segmentation and then each tissue is filled with the corresponding CT number of a specific tissue. By subtracting the template image from the uncorrected image, the residual image with image detail and shading artifact are generated. The shading artifact is mainly low-frequency signals while the image details are mainly high-frequency signals. Therefore, we proposed an adaptive filter to separate the shading artifact and image details accurately. Finally, the estimated shading artifacts are deleted from the raw image to generate the corrected image. RESULTS On the Catphan©504 study, the error of CT number in the corrected image's region of interest (ROI) is reduced from 109 to 11 HU, and the image contrast is increased by a factor of 1.46 on average. On the patient pelvis study, the error of CT number in selected ROI is reduced from 198 to 10 HU. The SNU calculated from the ROIs decreases from 24% to 9% after correction. CONCLUSIONS The proposed shading correction method using DCNN and AF may find a useful application in future clinical practice.
Collapse
Affiliation(s)
- Xiaokun Liang
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
- Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen 518055, China
| | - Na Li
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
- Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen 518055, China
| | - Zhicheng Zhang
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
- Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen 518055, China
| | - Shaode Yu
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
- Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen 518055, China
| | - Wenjian Qin
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
- Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen 518055, China
| | - Yafen Li
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
- Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen 518055, China
| | | | - Huailing Zhang
- School of Information Engineering, Guangdong Medical University, Dongguan 523808, China
| | - Yaoqin Xie
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| |
Collapse
|
14
|
Liang X, Jiang Y, Zhao W, Zhang Z, Luo C, Xiong J, Yu S, Yang X, Sun J, Zhou Q, Niu T, Xie Y. Scatter correction for a clinical cone‐beam CT system using an optimized stationary beam blocker in a single scan. Med Phys 2019; 46:3165-3179. [DOI: 10.1002/mp.13568] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2018] [Revised: 04/04/2019] [Accepted: 04/25/2019] [Indexed: 12/16/2022] Open
Affiliation(s)
- Xiaokun Liang
- Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences Shenzhen Guangdong 518055China
- Shenzhen Colleges of Advanced Technology University of Chinese Academy of Sciences Shenzhen Guangdong 518055China
| | - Yangkang Jiang
- Institute of Translational Medicine Zhejiang University Hangzhou Zhejiang 310016China
- Sir Run Run Shaw Hospital Zhejiang University School of Medicine Hangzhou Zhejiang 310016China
| | - Wei Zhao
- Department of Radiation Oncology Stanford University Stanford CA 94305USA
| | - Zhicheng Zhang
- Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences Shenzhen Guangdong 518055China
- Shenzhen Colleges of Advanced Technology University of Chinese Academy of Sciences Shenzhen Guangdong 518055China
| | - Chen Luo
- Institute of Translational Medicine Zhejiang University Hangzhou Zhejiang 310016China
- Sir Run Run Shaw Hospital Zhejiang University School of Medicine Hangzhou Zhejiang 310016China
| | - Jing Xiong
- Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences Shenzhen Guangdong 518055China
| | - Shaode Yu
- Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences Shenzhen Guangdong 518055China
- Shenzhen Colleges of Advanced Technology University of Chinese Academy of Sciences Shenzhen Guangdong 518055China
| | - Xiaoming Yang
- Sir Run Run Shaw Hospital Zhejiang University School of Medicine Hangzhou Zhejiang 310016China
| | - Jihong Sun
- Sir Run Run Shaw Hospital Zhejiang University School of Medicine Hangzhou Zhejiang 310016China
| | - Qinxuan Zhou
- Sir Run Run Shaw Hospital Zhejiang University School of Medicine Hangzhou Zhejiang 310016China
| | - Tianye Niu
- Institute of Translational Medicine Zhejiang University Hangzhou Zhejiang 310016China
- Sir Run Run Shaw Hospital Zhejiang University School of Medicine Hangzhou Zhejiang 310016China
| | - Yaoqin Xie
- Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences Shenzhen Guangdong 518055China
| |
Collapse
|
15
|
Shi L, Wang A, Wei J, Zhu L. Fast shading correction for cone-beam CT via partitioned tissue classification. Phys Med Biol 2019; 64:065015. [PMID: 30721886 DOI: 10.1088/1361-6560/ab0475] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
The quantitative use of cone beam computed tomography (CBCT) in radiation therapy is limited by severe shading artifacts, even with system embedded correction. We recently proposed effective shading correction methods, using planning CT (pCT) as prior information to estimate low-frequency errors in either the projection domain or image domain. In this work, we further improve the clinical practicality of our previous methods by removing the requirement of prior pCT images. Clinical CBCT images are typically composed of a limited number of tissues. By utilizing the low frequency characteristic of shading distribution, we first generate a 'shading-free' template image by enforcing uniformity on CBCT voxels of the same tissue type via a technique named partitioned tissue classification. Only a small subset of voxels in the template image are used in the correction process to generate sparse samples of shading artifacts. Local filtration, a Fourier transform based algorithm, is employed to efficiently process the sparse errors to compute a full-field distribution of shading artifacts for CBCT correction. We evaluate the method's performance using an anthropomorphic pelvis phantom and 6 pelvis patients. The proposed method improves the image quality of CBCT for both phantom and patients to a level matching that of pCT. On the pelvis phantom, the signal non-uniformity (SNU) is reduced from 12.11% to 3.11% and 8.40% to 2.21% on fat and muscle, respectively. The maximum CT number error is reduced from 70 to 10 HU and 73 to 11 HU on fat and muscle, respectively. On patients, the average SNU is reduced from 9.22% to 1.06% and 11.41% to 1.67% on fat and muscle, respectively. The maximum CT number error is reduced from 95 to 9 HU and 88 to 8 HU on fat and muscle, respectively. The typical processing time for one CBCT dataset is about 45 s on a standard PC.
Collapse
Affiliation(s)
- Linxi Shi
- Department of Radiology, Stanford University, Palo Alto, CA 94305, United States of America. Author to whom any correspondence should be addressed
| | | | | | | |
Collapse
|
16
|
Hashemi S, Huynh C, Sahgal A, Song WY, Nordström H, Eriksson M, Mainprize JG, Lee Y, Ruschin M. Cone-Beam CT image contrast and attenuation-map linearity improvement (CALI) for brain stereotactic radiosurgery procedures. J Appl Clin Med Phys 2018; 19:200-208. [PMID: 30338919 PMCID: PMC6236823 DOI: 10.1002/acm2.12477] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2018] [Revised: 09/19/2018] [Accepted: 09/24/2018] [Indexed: 11/11/2022] Open
Abstract
A Contrast and Attenuation‐map Linearity Improvement (CALI) framework is proposed for cone‐beam CT (CBCT) images used for brain stereotactic radiosurgery (SRS). The proposed framework is tailored to improve soft tissue contrast of a new point‐of‐care image‐guided SRS system that employs a challenging half cone beam geometry, but can be readily reproduced on any CBCT platform. CALI includes a pre‐ and post‐processing step. In pre‐processing we apply a shading and beam hardening artifact correction to the projections, and in post‐processing step we correct the dome/capping artifact on reconstructed images caused by the spatial variations in X‐ray energy generated by the bowtie‐filter. The shading reduction together with the beam hardening and dome artifact correction algorithms aim to improve the linearity and accuracy of the CT‐numbers (CT#). The CALI framework was evaluated using CatPhan to quantify linearity, contrast‐to‐noise (CNR), and CT# accuracy, as well as subjectively on patient images acquired on a clinical system. Linearity of the reconstructed attenuation‐map was improved from 0.80 to 0.95. The CT# mean absolute measurement error was reduced from 76.1 to 26.9 HU. The CNR of the acrylic insert in the sensitometry module was improved from 1.8 to 7.8. The resulting clinical brain images showed substantial improvements in soft tissue contrast visibility, revealing structures such as ventricles which were otherwise undetectable in the original clinical images obtained from the system. The proposed reconstruction framework also improved CT# accuracy compared to the original images acquired on the system. For frameless image‐guided SRS, improving soft tissue visibility can facilitate evaluation of MR to CBCT co‐registration. Moreover, more accurate CT# may enable the use of CBCT for daily dose delivery measurements.
Collapse
Affiliation(s)
- SayedMasoud Hashemi
- Department of Radiation Oncology, Sunnybrook Health Sciences Centre, Toronto, ON, Canada
| | | | - Arjun Sahgal
- Department of Radiation Oncology, Sunnybrook Health Sciences Centre, Toronto, ON, Canada
| | - William Y Song
- Department of Radiation Oncology, Sunnybrook Health Sciences Centre, Toronto, ON, Canada
| | | | | | | | - Young Lee
- Department of Radiation Oncology, Sunnybrook Health Sciences Centre, Toronto, ON, Canada
| | - Mark Ruschin
- Department of Radiation Oncology, Sunnybrook Health Sciences Centre, Toronto, ON, Canada
| |
Collapse
|
17
|
Zhao W, Vernekohl D, Han F, Han B, Peng H, Yang Y, Xing L, Min JK. A unified material decomposition framework for quantitative dual‐ and triple‐energy CT imaging. Med Phys 2018; 45:2964-2977. [DOI: 10.1002/mp.12933] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2017] [Revised: 01/26/2018] [Accepted: 02/25/2018] [Indexed: 12/16/2022] Open
Affiliation(s)
- Wei Zhao
- Department of Radiation Oncology, Stanford University, Stanford, CA, 94305, USA.,Department of Biomedical Engineering, Huazhong University of Science and Technology, Hubei, China
| | - Don Vernekohl
- Department of Radiation Oncology, Stanford University, Stanford, CA, 94305, USA
| | - Fei Han
- Department of Radiation Oncology, Stanford University, Stanford, CA, 94305, USA.,Department of Radiation Oncology, Sun Yat-sen University Cancer Center, Guangzhou, Guangdong, China
| | - Bin Han
- Department of Radiation Oncology, Stanford University, Stanford, CA, 94305, USA
| | - Hao Peng
- Department of Radiation Oncology, Stanford University, Stanford, CA, 94305, USA
| | - Yong Yang
- Department of Radiation Oncology, Stanford University, Stanford, CA, 94305, USA
| | - Lei Xing
- Department of Radiation Oncology, Stanford University, Stanford, CA, 94305, USA
| | - James K Min
- Dalio Institute of Cardiovascular Imaging, New York-Presbyterian Hospital and Weill Cornell Medical College, New York, NY, 10021, USA
| |
Collapse
|
18
|
Vedantham S, Karellas A. Emerging Breast Imaging Technologies on the Horizon. Semin Ultrasound CT MR 2018; 39:114-121. [PMID: 29317033 DOI: 10.1053/j.sult.2017.09.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Early detection of breast cancers by mammography in conjunction with adjuvant therapy has contributed to reduction in breast cancer mortality. Mammography remains the "gold-standard" for breast cancer screening but is limited by tissue superposition. Digital breast tomosynthesis and more recently, dedicated breast computed tomography have been developed to alleviate the tissue superposition problem. However, all of these modalities rely upon x-ray attenuation contrast to provide anatomical images, and there are ongoing efforts to develop and clinically translate alternative modalities. These emerging modalities could provide for new contrast mechanisms and may potentially improve lesion detection and diagnosis. In this article, several of these emerging modalities are discussed with a focus on technologies that have advanced to the stage of in vivo clinical evaluation.
Collapse
Affiliation(s)
- Srinivasan Vedantham
- Department of Medical Imaging, University of Arizona College of Medicine, Banner University Medical Center, Tucson, AZ.
| | - Andrew Karellas
- Department of Medical Imaging, University of Arizona College of Medicine, Banner University Medical Center, Tucson, AZ
| |
Collapse
|
19
|
Shi L, Vedantham S, Karellas A, Zhu L. The role of off-focus radiation in scatter correction for dedicated cone beam breast CT. Med Phys 2017; 45:191-201. [PMID: 29159941 DOI: 10.1002/mp.12686] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2017] [Revised: 11/02/2017] [Accepted: 11/12/2017] [Indexed: 12/18/2022] Open
Abstract
PURPOSE Dedicated cone beam breast CT (CBBCT) suffers from x-ray scatter contamination. We aim to identify the source of the significant difference between the scatter distributions estimated by two recent methods proposed by our group and to investigate its effect on CBBCT image quality. METHOD We recently proposed two novel methods of scatter correction for CBBCT, using a library based (LB) technique and a forward projection (FP) model. Despite similar enhancement on CBBCT image qualities, these two methods obtain very different scatter distributions. We hypothesize that the off-focus radiation (OFR) is the contributor and results in nontrivial signals in x-ray projections, which is ignored in the scatter estimation via the LB method. Experiments using a thin wire test tool are designed to study the effect of OFR on CBBCT spatial resolution by measuring the point spread function (PSF) and the modulation transfer function (MTF). A narrow collimator setting is used to suppress the OFR-induced signals. In addition, "PSFs" and "MTFs" are measured on clinical CBBCT images obtained by the LB and FP methods using small calcifications as point sources. The improvement of spatial resolution achieved by suppressing OFR in the wire experiment as well as in the clinical study is quantified by the improvement ratios of PSFs and spatial frequencies at different MTF values. Our hypothesis that OFR causes the imaging difference between the FP and LB methods is verified if these ratios obtained from experimental and clinical data are consistent. RESULTS In the wire experiment, the results show that suppression of OFR increases the maximum signal of the PSF by about 14% and reduces the full-width-at-half-maximum (FWHM) by about 12.0%. Similar improvement on spatial resolution is achieved by the FP method compared with the LB method in the patient study. The improvement ratios of spatial frequencies at different MTF values without OFR match very well in both studies at a level of around 16%, with an average root-mean-square difference of 0.47%. CONCLUSION The results of the wire experiment and the clinical study indicate that the main difference between the LB and FP methods is whether the OFR-induced signals are included after scatter correction. Our study further shows that OFR significantly affects the image spatial resolution of CBBCT, indicating that the visualization of micro-calcifications is susceptible to OFR contamination. Our finding is therefore important in further improvement of diagnostic performance of CBBCT.
Collapse
Affiliation(s)
- Linxi Shi
- Nuclear and Radiological Engineering and Medical Physics Programs, The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA.,Department of Radiology, Stanford University, Palo Alto, CA, 94305, USA
| | - Srinivasan Vedantham
- Department of Medical Imaging, University of Arizona College of Medicine, Tucson, AZ, 85724, USA.,Banner University Medical Center, Tucson, AZ, 85724, USA
| | - Andrew Karellas
- Department of Medical Imaging, University of Arizona College of Medicine, Tucson, AZ, 85724, USA.,Banner University Medical Center, Tucson, AZ, 85724, USA
| | - Lei Zhu
- Nuclear and Radiological Engineering and Medical Physics Programs, The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA.,Department of Modern Physics, School of Physical Sciences, University of Science and Technology of China, Hefei, Anhui, 230026, China
| |
Collapse
|