1
|
Tan D, Wang Y, Fan H, Jin J, Sun X, Dhanjai, Wang D. Magnetic surface-imprinted polymer microspheres coupled with HPLC-MS/MS for sensitive detection of amphetamine-type drugs in water. J Chromatogr A 2024; 1730:465097. [PMID: 38889583 DOI: 10.1016/j.chroma.2024.465097] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2024] [Revised: 06/12/2024] [Accepted: 06/14/2024] [Indexed: 06/20/2024]
Abstract
Magnetic surface imprinted polymer microspheres (Fe3O4@MIPs) were successfully synthesized via Pickering emulsion polymerization, utilizing N-Methylphenethylamine as a surrogate template for amphetamine-type drugs. Fe3O4@MIPs not only possessed excellent dispersibility and enough magnetic properties in aqueous solutions, but also displayed good selectivity towards six amphetamines, with an imprinting factor ranging from 1.8 to 2.6. The adsorption kinetics closely aligned with the pseudo-second-order model, and the adsorption efficiency exceeds 80 % for each amphetamine at equilibrium. Fe3O4@MIPs were then employed as the efficient adsorbents for the extraction of amphetamine drugs. Extraction parameters, including sample pH, the mass of adsorbent, and the type and volume of eluting solvent, were carefully optimized. In combination with the high performance liquid chromatography tandem triple quadrupole mass spectrometry (HPLC-MS/MS), a selective magnetic solid-phase extraction (MISPE) method utilizing Fe3O4@MIPs was developed for the detection of six amphetamines in water samples. The limits of detection and limits of quantitation were determined to be 5.2∼23 ng L-1 and 17∼77 ng L-1, respectively. Recoveries for the six target drugs from lake water and sewage samples fell within the range of 87.2∼110 %. Additionally, the MISPE-HPLC-MS/MS method exhibited excellent repeatability, with a precision below 8.5 % at two spiking levels. The prepared Fe3O4@MIPs possessed the advantages of high selectivity, straightforward preparation, facile separation and good reusability, and was highly suitable for the efficient extraction of amphetamine-type substances in complex environmental water.
Collapse
Affiliation(s)
- Dongqin Tan
- College of Environmental Science and Engineering, Dalian Maritime University, No.1 Linghai Road, Dalian, 116026, China.
| | - Yue Wang
- College of Environmental Science and Engineering, Dalian Maritime University, No.1 Linghai Road, Dalian, 116026, China
| | - Haocheng Fan
- College of Environmental Science and Engineering, Dalian Maritime University, No.1 Linghai Road, Dalian, 116026, China
| | - Jing Jin
- Key Laboratory of Separation Sciences for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, 116023, China
| | - Xiaoli Sun
- Department of Chemistry, Lishui University, Lishui, 32300, China
| | - Dhanjai
- Department of Chemistry, University of Allahabad, India
| | - Degao Wang
- College of Environmental Science and Engineering, Dalian Maritime University, No.1 Linghai Road, Dalian, 116026, China
| |
Collapse
|
2
|
Rahimpoor R, Soleymani-Ghoozhdi D, Firoozichahak A, Alizadeh S. Needle trap device technique: From fabrication to sampling. Talanta 2024; 276:126255. [PMID: 38776771 DOI: 10.1016/j.talanta.2024.126255] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2023] [Revised: 03/17/2024] [Accepted: 05/11/2024] [Indexed: 05/25/2024]
Abstract
Needle Trap Device (NTD) as a novel, versatile, and eco-friendly technique has played an important role in analytical and environmental chemistry. The distinctive role of this interdisciplinary technique can be defended through the sampling and analysis of biological samples and industrial pollutants in gaseous and liquid environments. In recent years, significant efforts have been made to enhance the performance of the needle trap device resulting in the development of novel extraction routes by various packing materials with improved selectivity and enhanced adsorption characteristics. These achievements can lead to the facilitated pre-concentration of desired analytes. This review tries to have a comparative and comprehensive survey of the three important areas of NTD technique: I) Fabrication and preparation procedures of NTDs; II) Sampling techniques of pollutants using NTDs; and III) Employed materials as adsorbents in NTDs. In the packing-material section, the commercial and synthetic adsorbents such as carbon materials, metal-organic frameworks, aerogel, and polymers are considered. Furthermore, the limitations and potential areas for future development of the NTD technique are presented.
Collapse
Affiliation(s)
- Razzagh Rahimpoor
- Department of Occupational Health Engineering, Research Center for Health Sciences, School of Health, Larestan University of Medical Sciences, Larestan, Iran
| | | | - Ali Firoozichahak
- Department of Occupational Health, Faculty of Health, Social Determinants of Health Research Center, Gonabad University of Medical Science, Gonabad, Iran.
| | - Saber Alizadeh
- Department of Chemistry, Bu-Ali-Sina University, Hamedan, Iran
| |
Collapse
|
3
|
Nourani N, Taghvimi A, Bavili-Tabrizi A, Javadzadeh Y, Dastmalchi S. Microextraction Techniques for Sample Preparation of Amphetamines in Urine: A Comprehensive Review. Crit Rev Anal Chem 2024; 54:1304-1319. [PMID: 36093632 DOI: 10.1080/10408347.2022.2113028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
Abstract
Psychological disorders and dramatic social problems are serious concerns regarding the abuse of amphetamine and its stimulant derivatives worldwide. Consumers of such drugs experience great euphoria along with serious health problems. Determination and quantification of amphetamine-type stimulants are indispensable skills for clinical and forensic laboratories. Analysis of low drug doses in bio-matrices necessitates applications of simple and also effective preparation steps. The preparation procedures not only eliminate adverse matrix effects, but also provide reasonable clean-up and pre-concentration benefits. The current review presents different methods used for sample preparation of amphetamines from urine as the most frequently used biological matrix. The advantages and limitations of various sample preparation methods were discussed focusing on the miniaturized methods.
Collapse
Affiliation(s)
- Nasim Nourani
- Student Research Committee, Tabriz University of Medical Sciences, Tabriz, Iran
- Biotechnology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
- Department of Medicinal Chemistry, Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Arezou Taghvimi
- Biotechnology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Ahad Bavili-Tabrizi
- Department of Medicinal Chemistry, Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
- Pharmaceutical Analysis Research Center and Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Yousef Javadzadeh
- Biotechnology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
- Department of Pharmaceutics, Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Siavoush Dastmalchi
- Biotechnology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
- Department of Medicinal Chemistry, Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
- Faculty of Pharmacy, Near East University, North Cyprus, Turkey
| |
Collapse
|
4
|
Cavalcante JA, Souza JC, Rohwedder JJR, Maldaner AO, Pasquini C, Hespanhol MC. A compact Fourier-transform near-infrared spectrophotometer and chemometrics for characterizing a comprehensive set of seized ecstasy samples. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2024; 314:124163. [PMID: 38513320 DOI: 10.1016/j.saa.2024.124163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/09/2024] [Revised: 03/06/2024] [Accepted: 03/14/2024] [Indexed: 03/23/2024]
Abstract
A comprehensive data set of ecstasy samples containing MDMA (N-methyl-3,4-methylenedioxyamphetamine) and MDA (3,4-methylenedioxyamphetamine) seized by the Brazilian Federal Police was characterized using spectral data obtained by a compact, low-cost, near-infrared Fourier-transform based spectrophotometer. Qualitative and quantitative characterization was accomplished using soft independent modeling of class analogy (SIMCA), linear discriminant analysis (LDA) classification, discriminating partial least square (PLS-DA), and regression models based on partial least square (PLS). By applying chemometric analysis, a protocol can be proposed for the in-field screening of seized ecstasy samples. The validation led to an efficiency superior to 96 % for ecstasy classification and estimating total actives, MDMA, and MDA content in the samples with a root mean square error of validation of 4.4, 4.2, and 2.7 % (m/m), respectively. The feasibility and drawbacks of the NIR technology applied to ecstasy characterization and the compromise between false positives and false negatives rate achieved by the classification models are discussed and a new approach to improve the classification robustness was proposed considering the forensic context.
Collapse
Affiliation(s)
- Jennifer A Cavalcante
- Chemistry Institute, State University of Campinas - UNICAMP, Rua Monteiro Lobato, 290, Campinas, SP, 13083-862, Brazil
| | - Jamille C Souza
- Group of Analysis and Education for Sustainability (GAES), Chemistry Department, Federal University of Viçosa (UFV), Viçosa, MG, 36570-900, Brazil
| | - Jarbas J R Rohwedder
- Chemistry Institute, State University of Campinas - UNICAMP, Rua Monteiro Lobato, 290, Campinas, SP, 13083-862, Brazil
| | - Adriano O Maldaner
- National Institute of Criminalistics, Federal Police, SAIS Quadra 07 Lote 23, 70610-200 Brasília, DF, Brazil
| | - Celio Pasquini
- Chemistry Institute, State University of Campinas - UNICAMP, Rua Monteiro Lobato, 290, Campinas, SP, 13083-862, Brazil
| | - Maria C Hespanhol
- Group of Analysis and Education for Sustainability (GAES), Chemistry Department, Federal University of Viçosa (UFV), Viçosa, MG, 36570-900, Brazil.
| |
Collapse
|
5
|
Anzar N, Suleman S, Singh Y, Parvez S, Khanuja M, Pilloton R, Narang J. Wearable Electrochemical Glove-Based Analytical Device (eGAD) for the Detection of Methamphetamine Employing Silver Nanoparticles. BIOSENSORS 2023; 13:934. [PMID: 37887127 PMCID: PMC10605403 DOI: 10.3390/bios13100934] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Revised: 09/29/2023] [Accepted: 10/13/2023] [Indexed: 10/28/2023]
Abstract
Illicit drug misuse has become a widespread issue that requires continuous drug monitoring and diagnosis. Wearable electrochemical drug detection devices possess the potential to function as potent screening instruments in the possession of law enforcement personnel, aiding in the fight against drug trafficking and facilitating forensic investigations conducted on site. These wearable sensors are promising alternatives to traditional detection methods. In this study, we present a novel wearable electrochemical glove-based analytical device (eGAD) designed especially for detecting the club drug, methamphetamine. To develop this sensor, we immobilized meth aptamer onto silver nanoparticle (AgNPs)-modified electrodes that were printed onto latex gloves. The characteristics of AgNPs, including their shape, size and purity were analysed using FTIR, SEM and UV vis spectrometry, confirming the successful synthesis. The developed sensor shows a 0.1 µg/mL limit of detection and 0.3 µg/mL limit of quantification with a linear concentration range of about 0.01-5 µg/mL and recovery percentages of approximately 102 and 103%, respectively. To demonstrate its applicability, we tested the developed wearable sensor by spiking various alcoholic and non-alcoholic drink samples. We found that the sensor remains effective for 60 days, making it a practical option with a reasonable shelf-life. The developed sensor offers several advantages, including its affordability, ease of handling and high sensitivity and selectivity. Its portable nature makes it an ideal tool for rapid detection of METH in beverages too.
Collapse
Affiliation(s)
- Nigar Anzar
- Department of Biotechnology, School of Chemical and Life Science, Jamia Hamdard University, New Delhi 110062, India; (N.A.); (S.S.); (Y.S.)
| | - Shariq Suleman
- Department of Biotechnology, School of Chemical and Life Science, Jamia Hamdard University, New Delhi 110062, India; (N.A.); (S.S.); (Y.S.)
| | - Yashda Singh
- Department of Biotechnology, School of Chemical and Life Science, Jamia Hamdard University, New Delhi 110062, India; (N.A.); (S.S.); (Y.S.)
| | - Suhel Parvez
- Department of Toxicology, School of Chemical and Life Science, Jamia Hamdard University, New Delhi 110062, India;
| | - Manika Khanuja
- Centre for Nanoscience and Nanotechnology, Jamia Millia Islamia, New Delhi 110025, India;
| | - Roberto Pilloton
- Institute of Crystallography, National Research Council (CNR-IC), 00015 Rome, Italy
| | - Jagriti Narang
- Department of Biotechnology, School of Chemical and Life Science, Jamia Hamdard University, New Delhi 110062, India; (N.A.); (S.S.); (Y.S.)
| |
Collapse
|
6
|
Akhoundian M, Alizadeh T. Enzyme-free colorimetric sensor based on molecularly imprinted polymer and ninhydrin for methamphetamine detection. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2023; 285:121866. [PMID: 36108410 DOI: 10.1016/j.saa.2022.121866] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Revised: 08/27/2022] [Accepted: 09/06/2022] [Indexed: 06/15/2023]
Abstract
Digital image colorimetry was applied to introduce a rapid, portable, and non-enzymatic test for methamphetamine measurements in urine. Imprinted polymer was synthesized in a simple, low-cost process and utilized for selective extraction of analyte from the sample in combination with the well-known ninhydrin color test. Applying the digital camera on a mobile phone, RGB basic color data were obtained, and calibration curves were developed for different concentrations of methamphetamine. Optimization of the test condition was carried out by changing some effective parameters such as extraction time and pH. The results were compared with some similar structural compounds indicating great potential for use as a selective and semi-quantitative field test for this drug. An acceptable linear range (5-100 μM) and detection limit (1.44 μM) as well as good agreement with the reference method, makes this fast portable method, an easy and reliable test for the analysis of methamphetamine in biological samples.
Collapse
Affiliation(s)
- Maedeh Akhoundian
- Department of Analytical Chemistry, Faculty of Chemistry, University College of Science, University of Tehran, P.O. Box 14155-6455, Tehran, Iran
| | - Taher Alizadeh
- Department of Analytical Chemistry, Faculty of Chemistry, University College of Science, University of Tehran, P.O. Box 14155-6455, Tehran, Iran.
| |
Collapse
|
7
|
Suzaei FM, Daryanavard SM, Abdel-Rehim A, Bassyouni F, Abdel-Rehim M. Recent molecularly imprinted polymers applications in bioanalysis. CHEMICAL PAPERS 2023; 77:619-655. [PMID: 36213319 PMCID: PMC9524737 DOI: 10.1007/s11696-022-02488-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/26/2022] [Accepted: 09/10/2022] [Indexed: 11/18/2022]
Abstract
Molecular imprinted polymers (MIPs) as extraordinary compounds with unique features have presented a wide range of applications and benefits to researchers. In particular when used as a sorbent in sample preparation methods for the analysis of biological samples and complex matrices. Its application in the extraction of medicinal species has attracted much attention and a growing interest. This review focus on articles and research that deals with the application of MIPs in the analysis of components such as biomarkers, drugs, hormones, blockers and inhibitors, especially in biological matrices. The studies based on MIP applications in bioanalysis and the deployment of MIPs in high-throughput settings and optimization of extraction methods are presented. A review of more than 200 articles and research works clearly shows that the superiority of MIP techniques lies in high accuracy, reproducibility, sensitivity, speed and cost effectiveness which make them suitable for clinical usage. Furthermore, this review present MIP-based extraction techniques and MIP-biosensors which are categorized on their classes based on common properties of target components. Extraction methods, studied sample matrices, target analytes, analytical techniques and their results for each study are described. Investigations indicate satisfactory results using MIP-based bioanalysis. According to the increasing number of studies on method development over the last decade, the use of MIPs in bioanalysis is growing and will further expand the scope of MIP applications for less studied samples and analytes.
Collapse
Affiliation(s)
- Foad Mashayekhi Suzaei
- Toxicology Laboratories, Monitoring the Human Hygiene Condition & Standard of Qeshm (MHCS Company), Qeshm Island, Iran
| | - Seyed Mosayeb Daryanavard
- grid.444744.30000 0004 0382 4371Department of Chemistry, Faculty of Science, University of Hormozgan, Bandar-Abbas, Iran
| | - Abbi Abdel-Rehim
- grid.5335.00000000121885934Department of Chemical Engineering and Biotechnology, Cambridge University, Cambridge, UK
| | - Fatma Bassyouni
- grid.419725.c0000 0001 2151 8157Chemistry of Natural and Microbial Products Department, Pharmaceutical industry Research Division, National Research Centre, Cairo, 12622 Egypt
| | - Mohamed Abdel-Rehim
- grid.5037.10000000121581746Functional Materials Division, Department of Applied Physics, School of Engineering Sciences, KTH Royal Institute of Technology, Stockholm, Sweden and Med. Solutions, Stockholm, Sweden
| |
Collapse
|
8
|
Rahimpoor R, Firoozichahak A, Alizadeh S, Soleymani-Ghoozhdi D, Mehregan F. Application of a needle trap device packed with a MIP@MOF nano-composite for efficient sampling and determination of airborne diazinon pesticide. RSC Adv 2022; 12:16267-16276. [PMID: 35733694 PMCID: PMC9153383 DOI: 10.1039/d2ra01614a] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2022] [Accepted: 05/24/2022] [Indexed: 11/21/2022] Open
Abstract
In this research, a novel, selective, and efficient porous adsorbent nano-composite comprising a molecularly imprinted polymer and a metal-organic framework (MIP@MOF) was employed for sampling, extraction and analysis of diazinon from the air by a needle trap device (NTD), for the first time. The synthesized MIP@MOF sorbent was characterized by the FT-IR, XRD, FE-SEM, TEM, and EDS techniques. Then, the effective parameters of the sampling (temperature and humidity) and desorption (time and temperature) process were optimized by response surface methodology (RSM). The optimum values of temperature and humidity of the sampling chamber were estimated to be 20 °C and 25.0%, respectively. Also, the highest response during the analyte desorption was obtained at 262 °C and 4.5 minutes. For more details, the performance of the MIP@MOF:NTD method was evaluated by determination of important parameters such as repeatability, reproducibility, the limit of detection (LOD), and the limit of quantification (LOQ), and then compared with the NIOSH 5600 standard method. The values of LOD and LOQ for the targeted analyte were determined to be 0.02 and 0.1 μg m-3, respectively. Also, the repeatability and reproducibility of the proposed method were obtained in the range of (3.9-5.1)% and (5.1-6.4)%, respectively, which proved the acceptable precision of the method. Furthermore, the results of this study exhibited a high correlation coefficient (R 2 = 0.9781) between the proposed method and the recommended NIOSH method. Finally, the proposed procedure was utilized for sampling and determination of the airborne diazinon in real conditions. These results indicated that the proposed MIP@MOF:NTD method can be employed as a fast, simple, environmentally friendly, selective, and effective procedure for sampling and determining diazinon in air.
Collapse
Affiliation(s)
- Razzagh Rahimpoor
- Department of Occupational Health Engineering, Research Center for Health Sciences, School of Health, Larestan University of Medical Sciences Larestan Iran
| | - Ali Firoozichahak
- Department of Occupational Health, Faculty of Health, Social Determinants of Health Research Center, Gonabad University of Medical Science Gonabad Iran
| | - Saber Alizadeh
- Department of Chemistry, Bu-Ali-Sina University Hamedan Iran
| | - Danial Soleymani-Ghoozhdi
- Student Research Committee, Faculty of Public Health, Kerman University of Medical Sciences Kerman Iran
| | - Faeze Mehregan
- School of Medicine, Shahrekord University of Medical Sciences Shahrekord Iran
| |
Collapse
|
9
|
Han C, Tan D, Wang Y, Yu Z, Sun X, Wang D. Selective extraction of synthetic cathinones new psychoactive substances from wastewater, urine and cocktail using dummy molecularly imprinted polymers. J Pharm Biomed Anal 2022; 215:114765. [PMID: 35447493 DOI: 10.1016/j.jpba.2022.114765] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Revised: 04/07/2022] [Accepted: 04/09/2022] [Indexed: 11/28/2022]
Abstract
Dummy molecularly imprinted polymers (DMIPs) for selective extraction of five common synthetic cathinones (SCs) were prepared by bulk polymerization. DMIPs materials possessed narrow diameter distribution (30-60 µm) and large specific surface area (329.6 m2 g-1). Imprinting factors for cathinone, methcathinone, mephedrone, methylone and ethylone were 1.11-1.82. DMIPs could also quickly adsorb SCs from aqueous solutions within 5 min. Therefore, the materials were used as solid-phase extraction (SPE) sorbents to selectively extract five SCs in complex samples. An accurate and sensitive analytical method based on DMIPs-SPE combined with HPLC-MS/MS was established. Under optimal conditions, the established method showed low limits of detection (0.002-0.1 ng mL-1), satisfactory recoveries (84.1-97.7%) and good repeatability (relative standard deviation (RSD) below 9%). The method was successfully verified using wastewater, urine and cocktail samples. Recoveries of SCs at three spiking levels were in the range of 75.1-98.6%, with RSD values below 7.0%. Compared with commercial sorbents, DMIPs showed better clean-up ability with matrix effect values of -24.1%-8.3% for all SCs in wastewater, urine and cocktail samples. Therefore, the developed DMIPs-SPE-HPLC-MS/MS strategy could be used as a specific and cost-effective method for sensitive determination of SCs in complex samples.
Collapse
Affiliation(s)
- Chang Han
- College of Environmental Science and Engineering, Dalian Maritime University, No. 1 Linghai Road, Dalian 116026, China
| | - Dongqin Tan
- College of Environmental Science and Engineering, Dalian Maritime University, No. 1 Linghai Road, Dalian 116026, China.
| | - Yue Wang
- College of Environmental Science and Engineering, Dalian Maritime University, No. 1 Linghai Road, Dalian 116026, China
| | - Zhonglin Yu
- College of Environmental Science and Engineering, Dalian Maritime University, No. 1 Linghai Road, Dalian 116026, China
| | - Xiaoli Sun
- Department of Chemistry, Lishui University, Lishui 32300, China
| | - Degao Wang
- College of Environmental Science and Engineering, Dalian Maritime University, No. 1 Linghai Road, Dalian 116026, China.
| |
Collapse
|
10
|
Dummy molecularly imprinted polymers for class-selective extraction of amphetamine-type stimulants from alcoholic and nonalcoholic beverages. J Chromatogr A 2022; 1663:462759. [PMID: 34986443 DOI: 10.1016/j.chroma.2021.462759] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2021] [Revised: 12/14/2021] [Accepted: 12/16/2021] [Indexed: 01/20/2023]
Abstract
Molecularly imprinted polymer was constructed for the first time through dummy imprinting strategy with homopiperonylamine as dummy template. The prepared dummy molecularly imprinted polymer (DMIP) showed high class selectivity towards the most popular amphetamine-type stimulants (ATSs) such as methamphetamine, amphetamine, 3,4-methylenedioxymethamphetamine, 3,4-methylenedioxy-amphetamine, and 3,4-methylenedioxy-N-ethylamphetamine with the imprinting factors of 2.280∼3.698 and selectivity factors of 1.654∼3.698. Moreover, ATSs could be rapidly adsorbed from water with the equilibrium time within 5 min. Hydrogen-bonding interaction between the amino groups of ATSs and carboxy on DMIP could be dominated adsorption mechanism. DMIP was employed as solid phase extraction (SPE) sorbents. Under the optimum extraction conditions, the method using DMIP-based SPE and high performance liquid chromatography-tandem mass spectrometry showed good linearity in the range of 0.025∼1.00 μmol L-1, good repeatability (RSD 4.8∼8.6%, n = 5) and low limits of quantification (0.007∼0.200 ng mL-1, S/N = 10). Satisfactory recoveries (72.5∼120%) with low RSD values (<10%) were obtained for all targets viz. spiked coke carbonated drinks, beer and cocktail. Compared with other commercial SPE sorbents, DMIP exhibited lower matrix effect (ME) for coke, beer and cocktail with ME values of 101∼124%, 75.8∼80.2% and 103∼128%, respectively. The obtained results suggested that the developed DMIP materials could be a potential candidate for pretreatment of ATSs in alcoholic and nonalcoholic beverages.
Collapse
|
11
|
Li C, Han D, Wu Z, Liang Z, Han F, Chen K, Fu W, Han D, Wang Y, Niu L. Polydopamine-based molecularly imprinted electrochemical sensor for the highly selective determination of ecstasy components. Analyst 2022; 147:3291-3297. [DOI: 10.1039/d2an00351a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
An electrochemical sensor based on molecularly imprinted polydopamine (MIP@PDA) for detecting the main components of ecstasy, MDA and MDMA.
Collapse
Affiliation(s)
- Chen Li
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, c/o School of Civil Engineering, Guangzhou University, Guangzhou 510006, PR China
| | - Dongfang Han
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, c/o School of Civil Engineering, Guangzhou University, Guangzhou 510006, PR China
| | - Zhifang Wu
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, c/o School of Civil Engineering, Guangzhou University, Guangzhou 510006, PR China
| | - Zhishan Liang
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, c/o School of Civil Engineering, Guangzhou University, Guangzhou 510006, PR China
| | - Fangjie Han
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, c/o School of Civil Engineering, Guangzhou University, Guangzhou 510006, PR China
| | - Ke Chen
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, c/o School of Civil Engineering, Guangzhou University, Guangzhou 510006, PR China
| | - Wencai Fu
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, c/o School of Civil Engineering, Guangzhou University, Guangzhou 510006, PR China
| | - Dongxue Han
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, c/o School of Civil Engineering, Guangzhou University, Guangzhou 510006, PR China
- Guangdong Provincial Key Laboratory of Psychoactive Substances Monitoring and Safety, Anti-Drug Technology Center of Guangdong Province, Guangzhou 510230, PR China
| | - Yukai Wang
- Guangdong Provincial Key Laboratory of Psychoactive Substances Monitoring and Safety, Anti-Drug Technology Center of Guangdong Province, Guangzhou 510230, PR China
| | - Li Niu
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, c/o School of Civil Engineering, Guangzhou University, Guangzhou 510006, PR China
| |
Collapse
|
12
|
Ye H, Shao J, Shi Y, Tan S, Su K, Zhang L, Shan X. Magnetic molecularly imprinted polymers for extraction of S-phenylmercapturic acid from urine samples followed by high-performance liquid chromatography. J Mol Recognit 2021; 34:e2930. [PMID: 34432338 DOI: 10.1002/jmr.2930] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Revised: 11/13/2020] [Accepted: 07/31/2021] [Indexed: 11/11/2022]
Abstract
In this study, magnetic molecularly imprinted polymers (MMIPs) were prepared and used as sorbents for extraction of S-phenylmercapturic acid (S-PMA) from urine samples, followed by high-performance liquid chromatography ultraviolet-visible (HPLC-UV/Vis) analysis. The MMIPs were synthesized by the copolymerization reaction of (phenylthio) acetic acid (template molecule), methacrylic acid (functional monomers) and ethylene glycol dimethacrylate (cross-linkers). The morphology, structure property and surface groups of the prepared MMIPs were characterized by scan electron microscopy, transmission electron microscopy, infrared spectroscopy, X-ray diffraction pattern, thermogravimetric analyses, Brunauer-Emmett-Teller and vibrating sample magnetometer. The selectivity of the MMIPs was investigated in the presence of interferents. Various parameters affecting the S-PMA extraction efficiency were investigated, including MMIPs amount, pH, sample volume, desorption solvent, as well as extraction and desorption time. The obtained optimal parameters were as follows: MMIPs amount (20 mg), pH (3.0), sample volume (5 mL), desorption solvent (methanol/acetic acid [9/1, v/v]), extraction time (30 minutes) and desorption time (2 minutes). The method was validated according to the Food and Drug Administration Guidance for Industry on Bioanalytical Method Validation. The calibration curve for the analyte was linear in the concentration range of 0.030-1.0 mg/L (r = 0.9995). The LOD and LOQ of the method were 0.0080 and 0.0267 mg/L, respectively. The enrichment factor of the MMIPs was 5. The relative standard deviations of intra- and inter-day tests were in the range of 3.8-5.1% and 3.9-6.3%, respectively. The recoveries at three different concentrations of 0.10, 0.50 and 0.80 mg/L ranged between 95.2% and 98.6%. In addition, the MMIPs could be reused for at least eight times. The proposed method was successfully applied to the determination of S-PMA in urine samples. In addition, this developed method could be used as a tool in the early screening and clinical diagnosis of benzene intoxication.
Collapse
Affiliation(s)
- Haipeng Ye
- Laboratory of Health testing, Hangzhou Occupational Disease Prevention and Control Hospital, Wenhui Street, Hangzhou, China
| | - Ji Shao
- Laboratory of Health testing, Hangzhou Occupational Disease Prevention and Control Hospital, Wenhui Street, Hangzhou, China
| | - Yanpeng Shi
- Laboratory of Health testing, Hangzhou Occupational Disease Prevention and Control Hospital, Wenhui Street, Hangzhou, China
| | - Siwei Tan
- Laboratory of Health testing, Hangzhou Occupational Disease Prevention and Control Hospital, Wenhui Street, Hangzhou, China
| | - Kewen Su
- Laboratory of Health testing, Hangzhou Occupational Disease Prevention and Control Hospital, Wenhui Street, Hangzhou, China
| | - Ling Zhang
- Laboratory of Health testing, Hangzhou Occupational Disease Prevention and Control Hospital, Wenhui Street, Hangzhou, China
| | - Xiaoyue Shan
- Laboratory of Health testing, Hangzhou Occupational Disease Prevention and Control Hospital, Wenhui Street, Hangzhou, China
| |
Collapse
|
13
|
Molecularly imprinted polymers as a selective sorbent for forensic applications in biological samples-a review. Anal Bioanal Chem 2021; 413:6013-6036. [PMID: 34430982 DOI: 10.1007/s00216-021-03596-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2021] [Revised: 07/14/2021] [Accepted: 08/02/2021] [Indexed: 01/09/2023]
Abstract
Molecularly imprinted polymers (MIP) consist of a molecular recognition technology with applicability in different areas, including forensic chemistry. Among the forensic applications, the use of MIP in biological fluid analysis has gained prominence. Biological fluids are complex samples that generally require a pre-treatment to eliminate interfering agents to improve the results of the analyses. In this review, we address the development of this molecular imprinting technology over the years, highlighting the forensic applications of molecularly imprinted polymers in biological sample preparation for analysis of stimulant drugs such as cocaine, amphetamines, and nicotine.
Collapse
|
14
|
Vaziri Heshi S, Shokoufi N. Fluorescence resonance energy transfer-thermal lens spectrometry (FRET-TLS) as molecular counting of methamphetamine. Mikrochim Acta 2021; 188:191. [PMID: 33999271 DOI: 10.1007/s00604-021-04842-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Accepted: 05/03/2021] [Indexed: 11/26/2022]
Abstract
A novel and sensitive approach has been presented for the determination of methamphetamine (METH) based on fluorescence resonance energy transfer-thermal lens spectrometry (FRET-TLS). Due to the affinity of fluorescein molecules to the surface of AuNPs through the electrostatic interaction and thereby caused reduction of the distance between fluorescein and AuNPs, the best way for de-excitation of excited fluorescein is FRET. The energy absorbed by fluorescein transferred to AuNPs causes enhancement of the thermal lens effect. The thermal lens of the fluorescence molecule could be enhanced through a proper acceptor. Upon the addition of methamphetamine, the fluorescein molecules are detached from the surface of AuNPs, due to the stronger adsorption of methamphetamine. As a result, the fluorescence of fluorescein recovered, and the thermal lens effect of fluorescein decreased. The mechanism of energy transfer was evaluated by two different methods including time-resolved spectroscopy and thermal lens spectrometry. Under the optimal conditions, the thermal lens signal was linearly proportional to methamphetamine concentration in the range 5 - 80 nM. The limit of detection and limit of quantitation were 1.5 nM and 4.5 nM, respectively. The detection volume and limit of molecules in the detection volume were 960 attoliter and 87 molecules, respectively. The method was successfully applied for the determination of methamphetamine in human blood plasma and urine.
Collapse
Affiliation(s)
- Samira Vaziri Heshi
- Analytical Instrumentation and Spectroscopy Laboratory, Chemistry and Chemical Engineering Research Center of Iran, Tehran, Iran
| | - Nader Shokoufi
- Analytical Instrumentation and Spectroscopy Laboratory, Chemistry and Chemical Engineering Research Center of Iran, Tehran, Iran.
| |
Collapse
|
15
|
Mulder HA, Halquist MS. Growing Trends in the Efficient and Selective Extraction of Compounds in Complex Matrices Using Molecularly Imprinted Polymers and Their Relevance to Toxicological Analysis. J Anal Toxicol 2021; 45:312-321. [PMID: 32672824 DOI: 10.1093/jat/bkaa079] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2020] [Revised: 05/08/2020] [Accepted: 05/26/2020] [Indexed: 11/12/2022] Open
Abstract
In the world of forensic and clinical toxicology, proper sample preparation is one of the key steps in identification and quantification of drugs of abuse. Traditional extraction methods such as solid-phase extraction and liquid-liquid extraction are often laborious and nonselective for the target analytes being measured. Molecularly imprinted polymers (MIPs) can be synthesized for sample extraction and their versatility allows the polymer to be employed in off-line, benchtop extractions or on/in-line instrument extractions, offering a faster and more selective sample preparation without the risk of interfering matrix effects. This review details the synthesis and applications of MIP materials for the extraction of drug compounds from biological matrices in publications from 1994 to today.
Collapse
Affiliation(s)
- Haley A Mulder
- Department of Pharmaceutics, Virginia Commonwealth University, School of Pharmacy, 410 N 12th St, Richmond, VA 23298, USA
| | - Matthew S Halquist
- Department of Pharmaceutics, Virginia Commonwealth University, School of Pharmacy, 410 N 12th St, Richmond, VA 23298, USA
| |
Collapse
|
16
|
Ahmad SM, Gonçalves OC, Oliveira MN, Neng NR, Nogueira JMF. Application of Microextraction-Based Techniques for Screening-Controlled Drugs in Forensic Context-A Review. Molecules 2021; 26:2168. [PMID: 33918766 PMCID: PMC8070059 DOI: 10.3390/molecules26082168] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2021] [Revised: 04/03/2021] [Accepted: 04/06/2021] [Indexed: 01/12/2023] Open
Abstract
The analysis of controlled drugs in forensic matrices, i.e., urine, blood, plasma, saliva, and hair, is one of the current hot topics in the clinical and toxicological context. The use of microextraction-based approaches has gained considerable notoriety, mainly due to the great simplicity, cost-benefit, and environmental sustainability. For this reason, the application of these innovative techniques has become more relevant than ever in programs for monitoring priority substances such as the main illicit drugs, e.g., opioids, stimulants, cannabinoids, hallucinogens, dissociative drugs, and related compounds. The present contribution aims to make a comprehensive review on the state-of-the art advantages and future trends on the application of microextraction-based techniques for screening-controlled drugs in the forensic context.
Collapse
Affiliation(s)
- Samir M. Ahmad
- Centro de Química Estrutural, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisboa, Portugal; (O.C.G.); (M.N.O.)
- Molecular Pathology and Forensic Biochemistry Laboratory, CiiEM, Campus Universitário—Quinta da Granja, Monte da Caparica, 2829-511 Caparica, Portugal
- Forensic and Psychological Sciences Laboratory Egas Moniz, Campus Universitário—Quinta da Granja, Monte da Caparica, 2829-511 Caparica, Portugal
| | - Oriana C. Gonçalves
- Centro de Química Estrutural, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisboa, Portugal; (O.C.G.); (M.N.O.)
| | - Mariana N. Oliveira
- Centro de Química Estrutural, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisboa, Portugal; (O.C.G.); (M.N.O.)
| | - Nuno R. Neng
- Centro de Química Estrutural, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisboa, Portugal; (O.C.G.); (M.N.O.)
- Departamento de Química e Bioquímica, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisboa, Portugal
| | - José M. F. Nogueira
- Centro de Química Estrutural, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisboa, Portugal; (O.C.G.); (M.N.O.)
- Departamento de Química e Bioquímica, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisboa, Portugal
| |
Collapse
|
17
|
Optimising factors affecting solid phase extraction performances of molecular imprinted polymer as recent sample preparation technique. Heliyon 2021; 7:e05934. [PMID: 33553728 PMCID: PMC7848654 DOI: 10.1016/j.heliyon.2021.e05934] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2020] [Revised: 10/30/2020] [Accepted: 01/06/2021] [Indexed: 01/20/2023] Open
Abstract
Molecular imprinted solid-phase extraction is the technique that uses molecular imprinted polymer as the sorbent in solid phase extraction. Molecular imprinted solid-phase extraction is effective and efficient for the extraction process and cleaning as compared with solid phase extraction (SPE) without molecular imprinted polymer. The complexity of variables in molecular imprinted solid-phase extraction arise as problems in the analysis, therefore it is necessary to optimize the extraction conditions of molecular imprinted solid-phase extraction. To achieve the sorption equilibrium and achieve the shortest time, certain parameters such as contact time, ion strength of sample, pH of sample, amount of sorbent, sample flow rate, addition of salt and buffer solution, washing solvent, elution solvent, and loading solvent need to be optimized. The selection of suitable properties and quantities of each factor greatly affect the formation of appropriate interactions between the sorbent and analytes. Percentage recovery is also influenced by formation of the appropriate bonds, sample flow rates, extraction time, salt addition, and sorbent mass. Therefore, in the future, molecular imprinted solid-phase extraction optimization has to consider and adjust various factors reviewed in this paper to form appropriate interactions between the absorbent and target molecules which have an impact on the optimal results.
Collapse
|
18
|
De Rycke E, Trynda A, Jaworowicz M, Dubruel P, De Saeger S, Beloglazova N. Capacitive sensing of an amphetamine drug precursor in aqueous samples: Application of novel molecularly imprinted polymers for benzyl methyl ketone detection. Biosens Bioelectron 2021; 172:112773. [DOI: 10.1016/j.bios.2020.112773] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2020] [Revised: 10/24/2020] [Accepted: 10/26/2020] [Indexed: 11/24/2022]
|
19
|
Masteri-Farahani M, Mashhadi-Ramezani S, Mosleh N. Molecularly imprinted polymer containing fluorescent graphene quantum dots as a new fluorescent nanosensor for detection of methamphetamine. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2020; 229:118021. [PMID: 31923795 DOI: 10.1016/j.saa.2019.118021] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2019] [Revised: 12/28/2019] [Accepted: 12/29/2019] [Indexed: 05/20/2023]
Abstract
A novel fluorescent nanosensor based on graphene quantum dots embedded within molecularly imprinted polymer (GQDs@MIP) was developed for detection and determination of methamphetamine (METH). The resulting GQDs@MIP nanocomposite exhibited higher methamphetamine selectivity in comparison with corresponding non-imprinted polymer (GQDs@NIP). Characterization of the GQDs@MIP nanocomposite was done by nitrogen adsorption and desorption analysis (BET method), transmission electron microscopy (TEM), photoluminescence (PL), ultraviolet-visible (UV-Vis), and Fourier transform infrared (FT-IR) spectroscopies. The fluorescence intensity of GQDs@MIP was efficiently quenched in the presence of methamphetamine template molecules while no quenching was observed in the presence of other analytes such as amphetamine, ibuprofen, codeine, and morphine. Using this method, the detection limit of 1.7 μg/L was obtained for methamphetamine determination.
Collapse
Affiliation(s)
| | | | - Nazanin Mosleh
- Faculty of Chemistry, Kharazmi University, Tehran, Islamic Republic of Iran
| |
Collapse
|
20
|
Sales TA, Ramalho TC. Computational design of synthetic receptors for drug detection: interaction between molecularly imprinted polymers and MDMA (3,4-methylenedioxymethamphetamine). Theor Chem Acc 2020. [DOI: 10.1007/s00214-020-2543-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
21
|
Yuvaraja S, Nawaz A, Liu Q, Dubal D, Surya SG, Salama KN, Sonar P. Organic field-effect transistor-based flexible sensors. Chem Soc Rev 2020; 49:3423-3460. [DOI: 10.1039/c9cs00811j] [Citation(s) in RCA: 126] [Impact Index Per Article: 31.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Flexible transistors are the next generation sensing technology, due to multiparametric analysis, reduced complexity, biocompatibility, lightweight with tunable optoelectronic properties. We summarize multitude of applications realized with OFETs.
Collapse
Affiliation(s)
- Saravanan Yuvaraja
- Sensors Lab
- Advanced Membranes and Porous Materials Center
- Computer, Electrical and Mathematical Science and Engineering Division
- King Abdullah University of Science and Technology
- Saudi Arabia
| | - Ali Nawaz
- Departamento de Física
- Universidade Federal do Paraná
- Caixa Postal 19044
- Curitiba
- Brazil
| | - Qian Liu
- School of Chemistry and Physics
- Queensland University of Technology (QUT)
- Brisbane
- Australia
| | - Deepak Dubal
- School of Chemistry and Physics
- Queensland University of Technology (QUT)
- Brisbane
- Australia
- Centre for Materials Science
| | - Sandeep G. Surya
- Sensors Lab
- Advanced Membranes and Porous Materials Center
- Computer, Electrical and Mathematical Science and Engineering Division
- King Abdullah University of Science and Technology
- Saudi Arabia
| | - Khaled N. Salama
- Sensors Lab
- Advanced Membranes and Porous Materials Center
- Computer, Electrical and Mathematical Science and Engineering Division
- King Abdullah University of Science and Technology
- Saudi Arabia
| | - Prashant Sonar
- School of Chemistry and Physics
- Queensland University of Technology (QUT)
- Brisbane
- Australia
- Centre for Materials Science
| |
Collapse
|
22
|
Ultra-trace detection of methamphetamine in biological samples using FFT-square wave voltammetry and nano-sized imprinted polymer/MWCNTs -modified electrode. Talanta 2019; 200:115-123. [DOI: 10.1016/j.talanta.2019.02.027] [Citation(s) in RCA: 39] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2018] [Revised: 02/03/2019] [Accepted: 02/04/2019] [Indexed: 11/22/2022]
|
23
|
Couto RA, Costa SS, Mounssef B, Pacheco JG, Fernandes E, Carvalho F, Rodrigues CM, Delerue-Matos C, Braga AA, Moreira Gonçalves L, Quinaz MB. Electrochemical sensing of ecstasy with electropolymerized molecularly imprinted poly(o-phenylenediamine) polymer on the surface of disposable screen-printed carbon electrodes. SENSORS AND ACTUATORS B: CHEMICAL 2019; 290:378-386. [DOI: 10.1016/j.snb.2019.03.138] [Citation(s) in RCA: 46] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
|
24
|
Sorribes-Soriano A, Esteve-Turrillas FA, Armenta S, Amorós P, Herrero-Martínez JM. Amphetamine-type stimulants analysis in oral fluid based on molecularly imprinting extraction. Anal Chim Acta 2019; 1052:73-83. [DOI: 10.1016/j.aca.2018.11.046] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2018] [Revised: 11/19/2018] [Accepted: 11/20/2018] [Indexed: 10/27/2022]
|
25
|
Silva ATMD, Bessa CDPB, Borges WDS, Borges KB. Bioanalytical methods for determining ecstasy components in biological matrices: A review. Trends Analyt Chem 2018. [DOI: 10.1016/j.trac.2018.08.001] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
|
26
|
A 3D nanoscale polyhedral oligomeric silsesquioxanes network for microextraction of polycyclic aromatic hydrocarbons. Mikrochim Acta 2018; 185:418. [PMID: 30120566 DOI: 10.1007/s00604-018-2950-z] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2018] [Accepted: 08/03/2018] [Indexed: 12/17/2022]
Abstract
Polyhedral oligomeric silsesquioxanes are 3D nanoscaled materials with large potential in solid phase microextraction (SPME). Here, as a case study, an octaglycidyldimethylsilyl modified polyhedral oligomeric silsesquioxane network is described. It was deposited on a stainless steel wire via a sol-gel method and used as a fiber coating for SPME of aromatic compounds. The uniform pore structure, high surface area, and hydrophobicity of the network make it susceptible toward isolation of non-polar and semi-polar chemical compounds. The performance of the fiber coating was tested with three classes of environmental pollutants, viz. chlorobenzenes (CBs), benzenes (benzene, toluene, ethylbenzene, xylene; known as BTEX), and polycyclic aromatic hydrocarbons. The effects of various types of sol-gel precursors on the fabrication and performance of fiber coatings were investigated. The extraction capability of the fiber coating was compared with the polydimethyl siloxane/divinylbenzene based commercial fiber. Parameters affecting headspace analysis and gas chromatographic quantitation were optimized. The method was applied to the quantification of PAHs, as model analytes, in tea, coffee and some environmental waters. Linear responses typically cover the 1-200 ng·L-1 concentration range, limits of detection are between 0.1 and 0.3 ng·L-1, intra-day relative standard deviation are <10%, and inter-day RSDs are <12%. The fiber has a long lifespan and can be used >200 times. Graphical abstract Schematic presentation of a headspace solid phase microextraction process which is implemented to the analysis of PAHs in tea and coffee samples. The SEM image of the SPME fiber coating, the 3D nanoscale polyhedral oligomeric silsesquioxane (POSS) network, and the POSS-epoxy molecular structure are shown.
Collapse
|
27
|
Three-dimensional nanofiber scaffolds are superior to two-dimensional mats in micro-oriented extraction of chlorobenzenes. Mikrochim Acta 2018; 185:322. [DOI: 10.1007/s00604-018-2858-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2018] [Accepted: 05/28/2018] [Indexed: 01/21/2023]
|
28
|
Saberi Z, Rezaei B, Faroukhpour H, Ensafi AA. A fluorometric aptasensor for methamphetamine based on fluorescence resonance energy transfer using cobalt oxyhydroxide nanosheets and carbon dots. Mikrochim Acta 2018; 185:303. [PMID: 29774421 DOI: 10.1007/s00604-018-2842-2] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2018] [Accepted: 05/10/2018] [Indexed: 12/12/2022]
Abstract
Cobalt oxyhydroxide (CoOOH) nanosheets are efficient fluorescence quenchers due to their specific optical properties and high surface area. The combination of CoOOH nanosheets and carbon dots (CDs) has not been used in any aptasensor based on fluorescence quenching so far. An aptamer based fluorometric assay is introduced that is making use of fluorescent CDs conjugated to the aptamer against methamphetamine (MTA), and of CoOOH nanosheets which reduce the fluorescence of the CDs as a quencher. The results revealed that the conjugated CDs with aptamers were able to enclose the CoOOH nanosheets. Consequently, fluorescence is quenched. If the aptamer on the CD binds MTA, the CDs are detached from CoOOH nanosheets. As a result, fluorescence is restored proportionally to zhe MTA concentration. The fluorometric limit of detection is 1 nM with a dynamic range from 5 to 156 nM. The method was validated by comparing the results obtained by the new method to those obtained by ion mobility spectroscopy. Theoretical studies showed that the distance between CoOOH nanosheet and C-Ds is approximately 7.6 Å which can illustrate the possibility of FRET phenomenon. The interactions of MTA and the aptamer were investigated using molecular dynamic simulation (MDS). Graphical abstract Carbon dots (C-Ds) were prepared from grape leaves, conjugated to aptamer, and adsorbed on CoOOH nanosheets. So, the fluorescence of C-Ds is quenched. On addition of MTA, fluorescence is restored.
Collapse
Affiliation(s)
- Zeinab Saberi
- Department of Chemistry, Isfahan University of Technology, Isfahan, 84156-83111, Islamic Republic of Iran
| | - Behzad Rezaei
- Department of Chemistry, Isfahan University of Technology, Isfahan, 84156-83111, Islamic Republic of Iran.
| | - Hossein Faroukhpour
- Department of Chemistry, Isfahan University of Technology, Isfahan, 84156-83111, Islamic Republic of Iran
| | - Ali Ashghar Ensafi
- Department of Chemistry, Isfahan University of Technology, Isfahan, 84156-83111, Islamic Republic of Iran
| |
Collapse
|
29
|
Taghvimi A, Ghorbani M, Hamishehkar H. Synthesis of a novel polymeric magnetic solid phase extraction adsorbent for selective extraction of amphetamine from urine samples coupled with high performance liquid chromatography. Drug Test Anal 2017; 10:832-838. [DOI: 10.1002/dta.2339] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2017] [Revised: 10/28/2017] [Accepted: 11/05/2017] [Indexed: 02/05/2023]
Affiliation(s)
- Arezou Taghvimi
- Biotechnology Research Center; Tabriz University of Medical Science; Tabriz Iran
| | - Marjan Ghorbani
- Stem Cell Research Center; Tabriz University of Medical Sciences; Tabriz Iran
| | - Hamed Hamishehkar
- Stem Cell Research Center; Tabriz University of Medical Sciences; Tabriz Iran
| |
Collapse
|
30
|
Azari MR, Barkhordari A, Zendehdel R, Heidari M. A novel needle trap device with nanoporous silica aerogel packed for sampling and analysis of volatile aldehyde compounds in air. Microchem J 2017. [DOI: 10.1016/j.microc.2017.06.019] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
31
|
Graniczkowska K, Pütz M, Hauser FM, De Saeger S, Beloglazova NV. Capacitive sensing of N-formylamphetamine based on immobilized molecular imprinted polymers. Biosens Bioelectron 2017; 92:741-747. [DOI: 10.1016/j.bios.2016.09.083] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2016] [Revised: 09/23/2016] [Accepted: 09/24/2016] [Indexed: 10/20/2022]
|
32
|
Yılmaz E, Garipcan B, Patra HK, Uzun L. Molecular Imprinting Applications in Forensic Science. SENSORS 2017; 17:s17040691. [PMID: 28350333 PMCID: PMC5419804 DOI: 10.3390/s17040691] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/16/2017] [Revised: 03/21/2017] [Accepted: 03/23/2017] [Indexed: 01/04/2023]
Abstract
Producing molecular imprinting-based materials has received increasing attention due to recognition selectivity, stability, cast effectiveness, and ease of production in various forms for a wide range of applications. The molecular imprinting technique has a variety of applications in the areas of the food industry, environmental monitoring, and medicine for diverse purposes like sample pretreatment, sensing, and separation/purification. A versatile usage, stability and recognition capabilities also make them perfect candidates for use in forensic sciences. Forensic science is a demanding area and there is a growing interest in molecularly imprinted polymers (MIPs) in this field. In this review, recent molecular imprinting applications in the related areas of forensic sciences are discussed while considering the literature of last two decades. Not only direct forensic applications but also studies of possible forensic value were taken into account like illicit drugs, banned sport drugs, effective toxins and chemical warfare agents in a review of over 100 articles. The literature was classified according to targets, material shapes, production strategies, detection method, and instrumentation. We aimed to summarize the current applications of MIPs in forensic science and put forth a projection of their potential uses as promising alternatives for benchmark competitors.
Collapse
Affiliation(s)
- Erkut Yılmaz
- Department of Biotechnology and Molecular Biology, Aksaray University, 68100 Aksaray, Turkey.
| | - Bora Garipcan
- Institute of Biomedical Engineering, Bogazici University, 34684 Istanbul, Turkey.
| | - Hirak K Patra
- Department of Clinical and Experimental Medicine, Linkoping University, 58225 Linköping, Sweden.
| | - Lokman Uzun
- Department of Chemistry, Hacettepe University, 06381 Ankara, Turkey.
| |
Collapse
|
33
|
Ghiasvand AR, Yazdankhah F. Single-step reinforced microextraction of polycyclic aromatic hydrocarbons from soil samples using an inside needle capillary adsorption trap with electropolymerized aniline/multi-walled carbon nanotube sorbent. J Chromatogr A 2017; 1487:47-53. [DOI: 10.1016/j.chroma.2017.01.056] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2016] [Revised: 01/02/2017] [Accepted: 01/22/2017] [Indexed: 01/17/2023]
|
34
|
Selective Extraction of Cholesterol from Dairy Samples Using a Polypyrrole Molecularly Imprinted Polymer and Determination by Gas Chromatography. FOOD ANAL METHOD 2016. [DOI: 10.1007/s12161-016-0686-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
35
|
Sorouraddin SM, Afshar Mogaddam MR. Development of molecularly imprinted-solid phase extraction combined with dispersive liquid–liquid microextraction for selective extraction and preconcentration of triazine herbicides from aqueous samples. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY 2016. [DOI: 10.1007/s13738-016-0823-0] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
36
|
Recent Developments and Applications of Solid Phase Microextraction (SPME) in Food and Environmental Analysis—A Review. CHROMATOGRAPHY 2015. [DOI: 10.3390/chromatography2030293] [Citation(s) in RCA: 128] [Impact Index Per Article: 14.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
37
|
Ma P, Yang W, Fan T, Liu H, Zhou Z, Li J, Zhang L, Xu W. Surface imprinted polymers for oil denitrification with the combination of computational simulation and multi-template molecular imprinting. POLYM ADVAN TECHNOL 2015. [DOI: 10.1002/pat.3476] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Pengfei Ma
- School of Material Science and Engineering; Jiangsu University; Zhenjiang 212013 China
| | - Wenming Yang
- School of Material Science and Engineering; Jiangsu University; Zhenjiang 212013 China
| | - Ting Fan
- School of Environment and Safety Engineering; Jiangsu University; Zhenjiang 212013 China
| | - Hong Liu
- Institute of Theoretical Chemistry, State Key Laboratory of Theoretical and Computational Chemistry; Jilin University; Changchun 130023 China
| | - Zhiping Zhou
- School of Material Science and Engineering; Jiangsu University; Zhenjiang 212013 China
| | - Jinhui Li
- School of Environment and Safety Engineering; Jiangsu University; Zhenjiang 212013 China
| | - Lin Zhang
- School of Environment and Safety Engineering; Jiangsu University; Zhenjiang 212013 China
| | - Wanzhen Xu
- School of Environment and Safety Engineering; Jiangsu University; Zhenjiang 212013 China
| |
Collapse
|
38
|
Colorimetric and bare eye determination of urinary methylamphetamine based on the use of aptamers and the salt-induced aggregation of unmodified gold nanoparticles. Mikrochim Acta 2014. [DOI: 10.1007/s00604-014-1349-8] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
39
|
Yang Y, Pan J, Hua W, Tu Y. An approach for the preparation of highly sensitive electrochemical impedimetric immunosensors for the detection of illicit drugs. J Electroanal Chem (Lausanne) 2014. [DOI: 10.1016/j.jelechem.2014.04.022] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
40
|
|
41
|
Zhang L, Wang ZH, Li H, Liu Y, Zhao M, Jiang Y, Zhao WS. Simultaneous determination of 12 illicit drugs in whole blood and urine by solid phase extraction and UPLC–MS/MS. J Chromatogr B Analyt Technol Biomed Life Sci 2014; 955-956:10-9. [DOI: 10.1016/j.jchromb.2014.02.007] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2013] [Revised: 01/21/2014] [Accepted: 02/10/2014] [Indexed: 10/25/2022]
|
42
|
Mehdinia A, Aziz-Zanjani MO. Advances for sensitive, rapid and selective extraction in different configurations of solid-phase microextraction. Trends Analyt Chem 2013. [DOI: 10.1016/j.trac.2013.05.013] [Citation(s) in RCA: 72] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|