1
|
Wang S, Zhang Z, Ma X, Yue Y, Li K, Meng Y, Wu Y. Bidirectional and Stepwise Rotation of Cells and Particles Using Induced Charge Electroosmosis Vortexes. BIOSENSORS 2024; 14:112. [PMID: 38534219 PMCID: PMC10968096 DOI: 10.3390/bios14030112] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/15/2024] [Revised: 02/08/2024] [Accepted: 02/18/2024] [Indexed: 03/28/2024]
Abstract
The rotation of cells is of significant importance in various applications including bioimaging, biophysical analysis and microsurgery. Current methods usually require complicated fabrication processes. Herein, we proposed an induced charged electroosmosis (ICEO) based on a chip manipulation method for rotating cells. Under an AC electric field, symmetric ICEO flow microvortexes formed above the electrode surface can be used to trap and rotate cells. We have discussed the impact of ICEO and dielectrophoresis (DEP) under the experimental conditions. The capabilities of our method have been tested by investigating the precise rotation of yeast cells and K562 cells in a controllable manner. By adjusting the position of cells, the rotation direction can be changed based on the asymmetric ICEO microvortexes via applying a gate voltage to the gate electrode. Additionally, by applying a pulsed signal instead of a continuous signal, we can also precisely and flexibly rotate cells in a stepwise way. Our ICEO-based rotational manipulation method is an easy to use, biocompatible and low-cost technique, allowing rotation regardless of optical, magnetic or acoustic properties of the sample.
Collapse
Affiliation(s)
- Shaoxi Wang
- School of Microelectronics, Northwestern Polytechnical University, Xi’an 710072, China; (S.W.); (Z.Z.); (X.M.); (K.L.); (Y.M.)
| | - Zhexin Zhang
- School of Microelectronics, Northwestern Polytechnical University, Xi’an 710072, China; (S.W.); (Z.Z.); (X.M.); (K.L.); (Y.M.)
- State Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Macau, China
- Faculty of Science and Technology, University of Macau, Macau, China
| | - Xun Ma
- School of Microelectronics, Northwestern Polytechnical University, Xi’an 710072, China; (S.W.); (Z.Z.); (X.M.); (K.L.); (Y.M.)
| | - Yuanbo Yue
- School of Microelectronics, Northwestern Polytechnical University, Xi’an 710072, China; (S.W.); (Z.Z.); (X.M.); (K.L.); (Y.M.)
| | - Kemu Li
- School of Microelectronics, Northwestern Polytechnical University, Xi’an 710072, China; (S.W.); (Z.Z.); (X.M.); (K.L.); (Y.M.)
| | - Yingqi Meng
- School of Microelectronics, Northwestern Polytechnical University, Xi’an 710072, China; (S.W.); (Z.Z.); (X.M.); (K.L.); (Y.M.)
| | - Yupan Wu
- School of Microelectronics, Northwestern Polytechnical University, Xi’an 710072, China; (S.W.); (Z.Z.); (X.M.); (K.L.); (Y.M.)
- Research & Development Institute, Northwestern Polytechnical University, Shenzhen 518000, China
- Yangtze River Delta Research Institute, Northwestern Polytechnical University, Taicang 215400, China
| |
Collapse
|
2
|
Safaefar F, Karamdel J, Veladi H, Maleki M. Design and implementation of a lab-on-a-chip for assisted reproductive technologies. BIOIMPACTS : BI 2023; 14:28902. [PMID: 39104621 PMCID: PMC11298026 DOI: 10.34172/bi.2023.28902] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Revised: 10/29/2023] [Accepted: 11/14/2023] [Indexed: 08/07/2024]
Abstract
Introduction The microfluidic device is highly optimized to remove oocytes from the cumulus-corona cell mass surrounding them. Additionally, it effectively captures and immobilizes the oocytes, aiding in assessing their quality and facilitating the injection of sperm into the oocyte. In this study, a novel microfluidic chip was designed and manufactured using conventional soft lithography methods. Methods This research proposes the utilization of a microfluidic chip as a substitute for the conventional manual procedures involved in oocyte denudation, trapping, and immobilization. The microfluidic chip was modeled and simulated using COMSOL Multiphysics® 5.2 software to optimize and enhance its design and performance. The microfluidic chip was fabricated using conventional injection molding techniques on a polydimethylsiloxane substrate by employing soft lithography methods. Results A hydrostatic force was applied to guide the oocyte through predetermined pathways to eliminate the cumulus cells surrounding the oocyte. The oocyte was subsequently confined within the designated trap region by utilizing hydraulic resistance along the paths and immobilized by applying vacuum force. Conclusion The application of this chip necessitates a lower level of operator expertise compared to enzymatic and mechanical techniques. Moreover, it is feasible to continuously monitor the oocyte's state throughout the procedure. There is a reduced need for cultural media compared to more standard approaches.
Collapse
Affiliation(s)
- Firooz Safaefar
- Department of Biomedical Engineering, Faculty of Technical and Engineering, South Tehran Branch, Islamic Azad University, Tehran, Iran
| | - Javad Karamdel
- Department of Electrical Engineering, Faculty of Technical and Engineering, South Tehran Branch, Islamic Azad University, Tehran, Iran
| | - Hadi Veladi
- Department of Biomedical Engineering, Faculty of Technical and Engineering, South Tehran Branch, Islamic Azad University, Tehran, Iran
- Microsystem Fabrication Laboratory, Faculty of Electrical and Computer Engineering, University of Tabriz, Tabriz, Iran
| | - Masoud Maleki
- Department of Biomedical Engineering, Faculty of Technical and Engineering, South Tehran Branch, Islamic Azad University, Tehran, Iran
- Department of Biology, Islamic Azad University, Tabriz Branch, Tabriz, Iran
| |
Collapse
|
3
|
Han X, Xu X, Yang C, Liu G. Microfluidic design in single-cell sequencing and application to cancer precision medicine. CELL REPORTS METHODS 2023; 3:100591. [PMID: 37725985 PMCID: PMC10545941 DOI: 10.1016/j.crmeth.2023.100591] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Revised: 07/01/2023] [Accepted: 08/24/2023] [Indexed: 09/21/2023]
Abstract
Single-cell sequencing (SCS) is a crucial tool to reveal the genetic and functional heterogeneity of tumors, providing unique insights into the clonal evolution, microenvironment, drug resistance, and metastatic progression of cancers. Microfluidics is a critical component of many SCS technologies and workflows, conferring advantages in throughput, economy, and automation. Here, we review the current landscape of microfluidic architectures and sequencing techniques for single-cell omics analysis and highlight how these have enabled recent applications in oncology research. We also discuss the challenges and the promise of microfluidics-based single-cell analysis in the future of precision oncology.
Collapse
Affiliation(s)
- Xin Han
- CUHK(SZ)-Boyalife Joint Laboratory of Regenerative Medicine Engineering, Biomedical Engineering Programme, School of Medicine, The Chinese University of Hong Kong, Shenzhen 518172, China; Ciechanover Institute of Precision and Regenerative Medicine, School of Medicine, The Chinese University of Hong Kong, Shenzhen 518172, China
| | - Xing Xu
- State Key Laboratory of Physical Chemistry of Solid Surfaces, MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Key Laboratory for Chemical Biology of Fujian Province, Innovation Laboratory for Sciences and Technologies of Energy Materials of Fujian Province, Department of Chemical Biology, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, P.R. China; Institute of Molecular Medicine, State Key Laboratory of Oncogenes and Related 12 Genes, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200240, P.R. China
| | - Chaoyang Yang
- State Key Laboratory of Physical Chemistry of Solid Surfaces, MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Key Laboratory for Chemical Biology of Fujian Province, Innovation Laboratory for Sciences and Technologies of Energy Materials of Fujian Province, Department of Chemical Biology, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, P.R. China; Institute of Molecular Medicine, State Key Laboratory of Oncogenes and Related 12 Genes, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200240, P.R. China.
| | - Guozhen Liu
- CUHK(SZ)-Boyalife Joint Laboratory of Regenerative Medicine Engineering, Biomedical Engineering Programme, School of Medicine, The Chinese University of Hong Kong, Shenzhen 518172, China; Ciechanover Institute of Precision and Regenerative Medicine, School of Medicine, The Chinese University of Hong Kong, Shenzhen 518172, China.
| |
Collapse
|
4
|
Lipp C, Koebel L, Loyon R, Bolopion A, Spehner L, Gauthier M, Borg C, Bertsch A, Renaud P. Microfluidic device combining hydrodynamic and dielectrophoretic trapping for the controlled contact between single micro-sized objects and application to adhesion assays. LAB ON A CHIP 2023; 23:3593-3602. [PMID: 37458004 PMCID: PMC10408363 DOI: 10.1039/d3lc00400g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2023] [Accepted: 06/27/2023] [Indexed: 07/18/2023]
Abstract
The understanding of cell-cell and cell-matrix interactions via receptor and ligand binding relies on our ability to study the very first events of their contact. Of particular interest is the interaction between a T cell receptor and its cognate peptide-major histocompatibility complex. Indeed, analyzing their binding kinetics and cellular avidity in large-scale low-cost and fast cell sorting would largely facilitate the access to cell-based cancer immunotherapies. We thus propose a microfluidic tool able to independently control two types of micro-sized objects, put them in contact for a defined time and probe their adhesion state. The device consists of hydrodynamic traps holding the first type of cell from below against the fluid flow, and a dielectrophoretic system to force the second type of object to remain in contact with the first one. First, the device is validated by performing an adhesion frequency assay between fibroblasts and fibronectin coated beads. Then, a study is conducted on the modification of the cellular environment to match the dielectrophoretic technology requirements without modifying the cell viability and interaction functionalities. Finally, we demonstrate the capability of the developed device to put cancer cells and a population of T cells in contact and show the discrimination between specific and non-specific interactions based on the pair lifetime. This proof-of-concept device lays the foundations for the development of next generation fast cell-cell interaction technologies.
Collapse
Affiliation(s)
- Clémentine Lipp
- Laboratory of Microsystems LMIS4, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland.
| | - Laure Koebel
- Institut FEMTO-ST, Département AS2M, Univ. Bourgogne Franche-Comté, CNRS, Besançon, France
| | - Romain Loyon
- Unité RIGHT, UMR INSERM 1098, Établissement Français du Sang Bourgogne Franche-Comté, Besançon, France
| | - Aude Bolopion
- Institut FEMTO-ST, Département AS2M, Univ. Bourgogne Franche-Comté, CNRS, Besançon, France
| | - Laurie Spehner
- Unité RIGHT, UMR INSERM 1098, Établissement Français du Sang Bourgogne Franche-Comté, Besançon, France
| | - Michaël Gauthier
- Institut FEMTO-ST, Département AS2M, Univ. Bourgogne Franche-Comté, CNRS, Besançon, France
| | - Christophe Borg
- Unité RIGHT, UMR INSERM 1098, Établissement Français du Sang Bourgogne Franche-Comté, Besançon, France
| | - Arnaud Bertsch
- Laboratory of Microsystems LMIS4, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland.
| | - Philippe Renaud
- Laboratory of Microsystems LMIS4, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland.
| |
Collapse
|
5
|
Wang Z, Chen X, Tian J, Wei J, Hu Y. Noncontact Manipulation of Intracellular Structure Based on Focused Surface Acoustic Waves. Anal Chem 2023; 95:827-835. [PMID: 36594897 DOI: 10.1021/acs.analchem.2c03007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Cell orientation is essential in many applications in biology, medicine, and chemistry, such as cellular injection, intracellular biopsy, and genetic screening. However, the manual cell orientation technique is a trial-and-error approach, which suffers from low efficiency and low accuracy. Although several techniques have improved these issues to a certain extent, they still face problems deforming or disrupting cell membranes, physical damage to the intracellular structure, and limited particle size. This study proposes a noncontact and noninvasive cell orientation method that rotates a cell using surface acoustic waves (SAWs). To realize the acoustic cell orientation process, we have fabricated a microdevice consisting of two pairs of focused interdigital transducers (FIDTs). Instead of rotating the entire cell, the proposed method rotates the intracellular structure, the cytoplasm, directly through the cell membrane by acoustic force. We have tested the rotational manipulation process on 30 zebrafish embryos. The system was able to orientate a cell to a target orientation with a one-time success rate of 93%. Furthermore, the postoperation survival rate was 100%. Our acoustic rotational manipulation technique is noninvasive and easy to use, which provides a starting point for cell-manipulation-essential tasks, such as single-cell analysis, organism studies, and drug discovery.
Collapse
Affiliation(s)
- Zenan Wang
- Center for Cognitive Technology, Chinese Academy of Sciences Shenzhen Institutes of Advanced Technology, Guangdong518055, China
| | - Xiaotong Chen
- Center for Cognitive Technology, Chinese Academy of Sciences Shenzhen Institutes of Advanced Technology, Guangdong518055, China.,School of Electrical Engineering, University of Jinan, Jinan250022, Shandong, China
| | - Jun Tian
- Center for Cognitive Technology, Chinese Academy of Sciences Shenzhen Institutes of Advanced Technology, Guangdong518055, China.,School of Electrical Engineering, University of Jinan, Jinan250022, Shandong, China
| | - Jun Wei
- School of Electrical Engineering, University of Jinan, Jinan250022, Shandong, China
| | - Ying Hu
- Center for Cognitive Technology, Chinese Academy of Sciences Shenzhen Institutes of Advanced Technology, Guangdong518055, China
| |
Collapse
|
6
|
Grigorev GV, Lebedev AV, Wang X, Qian X, Maksimov GV, Lin L. Advances in Microfluidics for Single Red Blood Cell Analysis. BIOSENSORS 2023; 13:117. [PMID: 36671952 PMCID: PMC9856164 DOI: 10.3390/bios13010117] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 12/04/2022] [Accepted: 12/23/2022] [Indexed: 05/24/2023]
Abstract
The utilizations of microfluidic chips for single RBC (red blood cell) studies have attracted great interests in recent years to filter, trap, analyze, and release single erythrocytes for various applications. Researchers in this field have highlighted the vast potential in developing micro devices for industrial and academia usages, including lab-on-a-chip and organ-on-a-chip systems. This article critically reviews the current state-of-the-art and recent advances of microfluidics for single RBC analyses, including integrated sensors and microfluidic platforms for microscopic/tomographic/spectroscopic single RBC analyses, trapping arrays (including bifurcating channels), dielectrophoretic and agglutination/aggregation studies, as well as clinical implications covering cancer, sepsis, prenatal, and Sickle Cell diseases. Microfluidics based RBC microarrays, sorting/counting and trapping techniques (including acoustic, dielectrophoretic, hydrodynamic, magnetic, and optical techniques) are also reviewed. Lastly, organs on chips, multi-organ chips, and drug discovery involving single RBC are described. The limitations and drawbacks of each technology are addressed and future prospects are discussed.
Collapse
Affiliation(s)
- Georgii V. Grigorev
- Data Science and Information Technology Research Center, Tsinghua Berkeley Shenzhen Institute, Tsinghua University, Shenzhen 518055, China
- Mechanical Engineering Department, University of California in Berkeley, Berkeley, CA 94720, USA
- School of Information Technology, Cherepovets State University, 162600 Cherepovets, Russia
| | - Alexander V. Lebedev
- Machine Building Department, Bauman Moscow State University, 105005 Moscow, Russia
| | - Xiaohao Wang
- Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China
| | - Xiang Qian
- Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China
| | - George V. Maksimov
- Faculty of Biology, Lomonosov Moscow State University, 119991 Moscow, Russia
- Physical metallurgy Department, Federal State Autonomous Educational Institution of Higher Education National Research Technological University “MISiS”, 119049 Moscow, Russia
| | - Liwei Lin
- Mechanical Engineering Department, University of California in Berkeley, Berkeley, CA 94720, USA
| |
Collapse
|
7
|
Kim H, Zhbanov A, Yang S. Microfluidic Systems for Blood and Blood Cell Characterization. BIOSENSORS 2022; 13:13. [PMID: 36671848 PMCID: PMC9856090 DOI: 10.3390/bios13010013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Revised: 12/16/2022] [Accepted: 12/19/2022] [Indexed: 06/17/2023]
Abstract
A laboratory blood test is vital for assessing a patient's health and disease status. Advances in microfluidic technology have opened the door for on-chip blood analysis. Currently, microfluidic devices can reproduce myriad routine laboratory blood tests. Considerable progress has been made in microfluidic cytometry, blood cell separation, and characterization. Along with the usual clinical parameters, microfluidics makes it possible to determine the physical properties of blood and blood cells. We review recent advances in microfluidic systems for measuring the physical properties and biophysical characteristics of blood and blood cells. Added emphasis is placed on multifunctional platforms that combine several microfluidic technologies for effective cell characterization. The combination of hydrodynamic, optical, electromagnetic, and/or acoustic methods in a microfluidic device facilitates the precise determination of various physical properties of blood and blood cells. We analyzed the physical quantities that are measured by microfluidic devices and the parameters that are determined through these measurements. We discuss unexplored problems and present our perspectives on the long-term challenges and trends associated with the application of microfluidics in clinical laboratories. We expect the characterization of the physical properties of blood and blood cells in a microfluidic environment to be considered a standard blood test in the future.
Collapse
Affiliation(s)
- Hojin Kim
- Department of Mechatronics Engineering, Dongseo University, Busan 47011, Republic of Korea
| | - Alexander Zhbanov
- School of Mechanical Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Republic of Korea
| | - Sung Yang
- School of Mechanical Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Republic of Korea
- Department of Biomedical Science and Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Republic of Korea
| |
Collapse
|
8
|
Puttaswamy SV, Bhattacharya G, Raj S, Bhalla N, Lee C, McLaughlin J. Effect of Functional Electrical Stimulation on Capillary Blood Flow to Muscle. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2022; 2022:1573-1576. [PMID: 36086637 DOI: 10.1109/embc48229.2022.9871395] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Functional electrical stimulation (FES) modifies red blood cells (RBCs) flux in blood capillaries of muscle. In this work, we aim to investigate changes in the RBC flux in small and large capillaries due to FES using zinc oxide nanowires (ZnO NWs) based electrode at different stimulation parameters. The RBC flux was significantly increased immediately after stimulation, which was evident from decreasing light intensity measured in the region of interest. Clinical Relevance- FES has numerous forms and functions. The benefit of FES is the increased blood flow to a muscle which is contracted abnormally. This work explores the use of FES to increase the blood flow and RBC flux in blood capillaries of stimulated muscle as FES generate muscle contraction and absorption.
Collapse
|
9
|
Sun J, Koukourakis N, Guck J, Czarske JW. Rapid computational cell-rotation around arbitrary axes in 3D with multi-core fiber. BIOMEDICAL OPTICS EXPRESS 2021; 12:3423-3437. [PMID: 34221669 PMCID: PMC8221929 DOI: 10.1364/boe.423035] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/18/2021] [Revised: 05/08/2021] [Accepted: 05/10/2021] [Indexed: 05/25/2023]
Abstract
Optical trapping is a vital tool in biology, allowing precise optical manipulation of nanoparticles, micro-robots, and cells. Due to the low risk of photodamage and high trap stiffness, fiber-based dual-beam traps are widely used for optical manipulation of large cells. Besides trapping, advanced applications like 3D refractive index tomography need a rotation of cells, which requires precise control of the forces, for example, the acting-point of the forces and the intensities in the region of interest (ROI). A precise rotation of large cells in 3D about arbitrary axes has not been reported yet in dual-beam traps. We introduce a novel dual-beam optical trap in which a multi-core fiber (MCF) is transformed to a phased array, using wavefront shaping and computationally programmable light. The light-field distribution in the trapping region is holographically controlled within 0.1 s, which determines the orientation and the rotation axis of the cell with small retardation. We demonstrate real-time controlled rotation of HL60 cells about all 3D axes with a very high degree of freedom by holographic controlled light through an MCF with a resolution close to the diffraction limit. For the first time, the orientation of the cell can be precisely controlled about all 3D axes in a dual-beam trap. MCFs provide much higher flexibility beyond the bulky optics, enabling lab-on-a-chip applications and can be easily integrated for applications like contactless cell surgery, refractive index tomography, cell-elasticity measurement, which require precise 3D manipulation of cells.
Collapse
Affiliation(s)
- Jiawei Sun
- Laboratory of Measurement and Sensor System Technique, TU Dresden, Helmholtzstrasse 18, 01069 Dresden, Germany
- Competence Center for Biomedical Computational Laser Systems (BIOLAS), TU Dresden, Dresden, Germany
| | - Nektarios Koukourakis
- Laboratory of Measurement and Sensor System Technique, TU Dresden, Helmholtzstrasse 18, 01069 Dresden, Germany
- Competence Center for Biomedical Computational Laser Systems (BIOLAS), TU Dresden, Dresden, Germany
| | - Jochen Guck
- Max Planck Institute for the Science of Light, Staudtstrasse 2, 91058 Erlangen, Germany
- Cluster of Excellence Physics of Life, TU Dresden, Dresden, Germany
| | - Jürgen W. Czarske
- Laboratory of Measurement and Sensor System Technique, TU Dresden, Helmholtzstrasse 18, 01069 Dresden, Germany
- Competence Center for Biomedical Computational Laser Systems (BIOLAS), TU Dresden, Dresden, Germany
- Cluster of Excellence Physics of Life, TU Dresden, Dresden, Germany
| |
Collapse
|
10
|
On-Chip Multiple Particle Velocity and Size Measurement Using Single-Shot Two-Wavelength Differential Image Analysis. MICROMACHINES 2020; 11:mi11111011. [PMID: 33212970 PMCID: PMC7698501 DOI: 10.3390/mi11111011] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/01/2020] [Revised: 11/13/2020] [Accepted: 11/14/2020] [Indexed: 12/11/2022]
Abstract
Precise and quick measurement of samples' flow velocities is essential for cell sorting timing control and reconstruction of acquired image-analyzed data. We developed a simple technique for the single-shot measurement of flow velocities of particles simultaneously in a microfluidic pathway. The speed was calculated from the difference in the particles' elongation in an acquired image that appeared when two wavelengths of light with different irradiation times were applied. We ran microparticles through an imaging flow cytometer and irradiated two wavelengths of light with different irradiation times simultaneously to those particles. The mixture of the two wavelength transmitted lights was divided into two wavelengths, and the images of the same microparticles for each wavelength were acquired in a single shot. We estimated the velocity from the difference of its elongation divided by the difference of irradiation time by comparing these two images. The distribution of polystyrene beads' velocity was parabolic and highest at the center of the flow channel, consistent with the expected velocity distribution of the laminar flow. Applying the calculated velocity, we also restored the accurate shapes and cross-sectional areas of particles in the images, indicating this simple method for improving of imaging flow cytometry and cell sorter for diagnostic screening of circulating tumor cells.
Collapse
|