Santos A, Macías N, Vega A, Abad S, Linares T, Aragoncillo I, Cruzado L, Pascual C, Goicoechea M, López-Gómez JM. Efficacy of enoxaparin in preventing coagulation during high-flux haemodialysis, expanded haemodialysis and haemodiafiltration.
Clin Kidney J 2020;
14:1120-1125. [PMID:
33841857 PMCID:
PMC8023216 DOI:
10.1093/ckj/sfaa057]
[Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2019] [Accepted: 03/18/2020] [Indexed: 12/16/2022] Open
Abstract
Background
Low-molecular-weight heparins (LMWHs) are easily dialysable with high-flow membranes; however, it is not clear whether the LMWH dose should be adjusted according to the membrane type and dialysis technique. This study aimed to evaluate the influence of the dialyser on anticoagulation of the extracorporeal dialysis circuit.
Methods
Thirteen patients received the same dose of LMWH through the arterial port via three dialysis techniques: high-flux haemodialysis (HF-HD), online haemodiafiltration (HDF) and expanded haemodialysis (HDx). All dialysis was performed under similar conditions: duration, 4 h; blood flow, 400 mL/min; and dialysate flow, 500 mL/min. Antifactor Xa (aXa) activity and activated partial thromboplastin time (APTT) were measured before and after the dialysis. Clotting time of the vascular access site after haemodialysis, visual clotting score of the dialyser and any complications with the extracorporeal circuit or bleeding were registered.
Results
Post-dialysis aXa activity in HF-HD (0.26 ± 0.02 U/mL) was significantly different from that in HDF (0.21 ± 0.02 U/mL, P = 0.024), and there was a trend in HDx (0.22 ± 0.01 U/mL, P = 0.05). APTT post-dialysis in HF-HD (30.5 ± 0.7 s) was significantly different from that in HDx (28.2 ± 0.64 s, P = 0.009) and HDF (28.8 ± 0.73 s, P = 0.009).
Conclusions
AXa activity in HDF was significantly lower than that in HF-HD, possibly because of more losses of LMWH through the dialyser. Given the higher anticoagulant loss in HDF and probably in HDx than in HF-HD, the enoxaparin dose administered may be adjusted according to the dialysis technique.
Collapse