1
|
Linsak DT, Kese D, Broznic D, Lusic DV, Cenov A, Moric M, Gobin I. Sea water whirlpool spa as a source of Legionella infection. JOURNAL OF WATER AND HEALTH 2021; 19:242-253. [PMID: 33901021 DOI: 10.2166/wh.2021.150] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Bacterial pneumonia caused by the inhalation of aerosols contaminated with Legionella spp. is also known as Legionnaires' disease. In this study, we report a case of pneumonia caused by Legionella pneumophila sg.1 in a 58-year-old man who visited a sea water-filled whirlpool within a hotel and spa complex. The patient's Legionella urine antigen test was positive for L. pneumophila sg.1. During the field study, samples were taken from both the outdoor and indoor sea water-filled pools. Samples from the whirlpool were culture positive for L. pneumophila sg.1. Typing results indicated sea water isolate belonged to Sequence type ST82 and Allentown/France MAb subgroup. In vitro experiments showed that L. pneumophila strains are able to survive within sea water up to 7 days, and survival time is prolonged with sea water dilution. Also, our results indicate that L. pneumophila Allentown strain was the most resistant to adverse conditions in sea water with the highest values of DT50 (420 min) and DT90 (1,396 min). The possible source of infection was adding potable water for filling up the whirlpool. The survival of the L. pneumophila in additionally conditioned sea water should be considered in a further study.
Collapse
Affiliation(s)
- Dijana Tomic Linsak
- Faculty of Medicine, Department of Health Ecology, University of Rijeka, Brace Branchetta 20, 51000 Rijeka, Croatia E-mail: ; Teaching Institute of Public Health of Primorje-Gorski Kotar County, Kresimirova 52a, 51000 Rijeka, Croatia
| | - Darja Kese
- Institute of Microbiology and Immunology, Faculty of Medicine, University of Ljubljana, Zaloska 4, 1000 Ljubljana, Slovenia
| | - Dalibor Broznic
- Faculty of Medicine, Department of Medical Chemistry, Biochemistry and Clinical Chemistry, University of Rijeka, Brace Branchetta 20, 51000 Rijeka, Croatia
| | - Darija Vukic Lusic
- Faculty of Medicine, Department of Health Ecology, University of Rijeka, Brace Branchetta 20, 51000 Rijeka, Croatia E-mail: ; Teaching Institute of Public Health of Primorje-Gorski Kotar County, Kresimirova 52a, 51000 Rijeka, Croatia
| | - Arijana Cenov
- Teaching Institute of Public Health of Primorje-Gorski Kotar County, Kresimirova 52a, 51000 Rijeka, Croatia
| | - Milan Moric
- Teaching Institute of Public Health of Primorje-Gorski Kotar County, Kresimirova 52a, 51000 Rijeka, Croatia
| | - Ivana Gobin
- Faculty of Medicine, Department of Microbiology, University of Rijeka, Brace Branchetta 20, 51000 Rijeka, Croatia
| |
Collapse
|
2
|
Yakunin E, Kostyal E, Agmon V, Grotto I, Valinsky L, Moran-Gilad J. A Snapshot of the Prevalence and Molecular Diversity of Legionella pneumophila in the Water Systems of Israeli Hotels. Pathogens 2020; 9:pathogens9060414. [PMID: 32471136 PMCID: PMC7350324 DOI: 10.3390/pathogens9060414] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2020] [Revised: 05/19/2020] [Accepted: 05/23/2020] [Indexed: 11/16/2022] Open
Abstract
Exposure to Legionella spp. contaminated aerosols in hotel settings confers risk for travel-associated Legionnaire’s disease (TALD). In this study, we investigated the prevalence of Legionella contamination and its molecular diversity in hotels and resorts across Israel. The study was comprised of a convenience sample of water systems from 168 hotels and resorts countrywide, routinely inspected between March 2015 and February 2017. Isolation and quantitation of Legionella were performed in a water laboratory using the ISO 11731 method. The distribution of Legionella isolates was analyzed according to geography and source. The genetic diversity of a subset of isolates was analyzed by sequence-based typing (SBT) at the National Reference Laboratory for Legionella and compared to the national database. Out of 2830 samples tested, 470 (17%) obtained from 102 different premises (60% of hotels) were positive for Legionella spp. In 230 samples (49% of all positive, 8% of total samples), accounting for 37% of hotels, Legionella spp. counts exceeded the regulatory threshold of 1000 CFU/L. The most frequently contaminated water sources were cooling towers (38%), followed by faucets, hot tubs, water lines, and storage tanks (14–17% each). Furthermore, 32% and 17% of samples obtained from cooling towers and hot tubs, respectively, exceeded the regulatory thresholds. SBT was performed on 78 strains and revealed 27 different sequence types (STs), including two novel STs. The most prevalent STs found were ST1 (26%), ST87 (10%), ST93 (6%), and ST461 and ST1516 (5% each). Several L. pneumophila STs were found to be limited to certain geographical regions. This is the first study to investigate the prevalence and diversity of Legionella in hotels and resorts in Israel during non-outbreak environmental inspections. These findings will inform risk assessment, surveillance, and control measures of TALD.
Collapse
Affiliation(s)
- Eugenia Yakunin
- Central Laboratories and Public Health Services, Ministry of Health, Jerusalem 9134302, Israel; (E.Y.); (V.A.); (I.G.); (L.V.)
| | - Eszter Kostyal
- Department of Water Microbiology, Biolab Ltd., Jerusalem 9134001, Israel;
| | - Vered Agmon
- Central Laboratories and Public Health Services, Ministry of Health, Jerusalem 9134302, Israel; (E.Y.); (V.A.); (I.G.); (L.V.)
| | - Itamar Grotto
- Central Laboratories and Public Health Services, Ministry of Health, Jerusalem 9134302, Israel; (E.Y.); (V.A.); (I.G.); (L.V.)
- Department of Health Systems Management, School of Public Health, Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheva 8410501, Israel
| | - Lea Valinsky
- Central Laboratories and Public Health Services, Ministry of Health, Jerusalem 9134302, Israel; (E.Y.); (V.A.); (I.G.); (L.V.)
| | - Jacob Moran-Gilad
- Central Laboratories and Public Health Services, Ministry of Health, Jerusalem 9134302, Israel; (E.Y.); (V.A.); (I.G.); (L.V.)
- Department of Health Systems Management, School of Public Health, Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheva 8410501, Israel
- Correspondence:
| |
Collapse
|
3
|
Ginevra C, Chastang J, David S, Mentasti M, Yakunin E, Chalker VJ, Chalifa-Caspi V, Valinsky L, Jarraud S, Moran-Gilad J. A real-time PCR for specific detection of the Legionella pneumophila serogroup 1 ST1 complex. Clin Microbiol Infect 2019; 26:514.e1-514.e6. [PMID: 31525518 DOI: 10.1016/j.cmi.2019.09.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2019] [Revised: 08/28/2019] [Accepted: 09/01/2019] [Indexed: 11/16/2022]
Abstract
OBJECTIVE Legionella pneumophila serogroup 1 (Lp1) sequence type (ST) 1 is globally widespread in the environment and accounts for a significant proportion of Legionella infections, including nosocomial Legionnaires' disease (LD). This study aimed to design a sensitive and specific detection method for Lp ST1 that will underpin epidemiological investigations and risk assessment. METHODS A total of 628 Lp genomes (126 ST1s) were analyzed by comparative genomics. Interrogation of more than 900 accessory genes revealed seven candidate targets for specific ST1 detection and specific primers and hydrolysis probes were designed and evaluated. The analytical sensitivity and specificity of the seven primer and probe sets were evaluated on serially diluted DNA extracted from the reference strain CIP107629 and via qPCR applied on 200 characterized isolates. The diagnostic performance of the assay was evaluated on 142 culture-proven clinical samples from LD cases and a real-life investigation of a case cluster. RESULTS Of seven qPCR assays that underwent analytical validation, one PCR target (lpp1868) showed higher sensitivity and specificity for ST1 and ST1-like strains. The diagnostic performance of the assay using respiratory samples corresponded to a sensitivity of 95% (19/20) (95% CI (75.1-99.9)) and specificity of 100% (122/122) (95% CI (97-100)). The ST1 PCR assay could link two out of three culture-negative hospitalized LD cases to ST1 during a real-time investigation. CONCLUSION Using whole genome sequencing (WGS) data, we developed and validated a sensitive and specific qPCR assay for the detection of Lp1 belonging to the ST1 clonal complex by amplification of the lpp1868 gene. The ST1 qPCR is expected to deliver an added value for Lp control and prevention, in conjunction with other recently developed molecular assays.
Collapse
Affiliation(s)
- C Ginevra
- CIRI, Centre International de Recherche en Infectiologie, Legionella Pathogenesis Team, Univ Lyon, Inserm, U1111, Université Claude Bernard Lyon 1, CNRS, UMR5308, ENS de Lyon, F-69007, Lyon, France; National Reference Centre of Legionella, Institute of Infectious Agents, Hospices Civils de Lyon, Lyon, France; ESCMID Study Group for Legionella Infections (ESGLI), Basel, Switzerland
| | - J Chastang
- National Reference Centre of Legionella, Institute of Infectious Agents, Hospices Civils de Lyon, Lyon, France
| | - S David
- ESCMID Study Group for Legionella Infections (ESGLI), Basel, Switzerland; Pathogen Genomics, Welcome Trust Sanger Institute, Cambridge, UK; Respiratory and Vaccine Preventable Bacteria Reference Unit, Public Health England, London, UK
| | - M Mentasti
- ESCMID Study Group for Legionella Infections (ESGLI), Basel, Switzerland; Respiratory and Vaccine Preventable Bacteria Reference Unit, Public Health England, London, UK
| | - E Yakunin
- ESCMID Study Group for Legionella Infections (ESGLI), Basel, Switzerland; Central Laboratories, Public Health Services, Ministry of Health, Jerusalem, Israel
| | - V J Chalker
- ESCMID Study Group for Legionella Infections (ESGLI), Basel, Switzerland; Respiratory and Vaccine Preventable Bacteria Reference Unit, Public Health England, London, UK
| | - V Chalifa-Caspi
- National Institute for Biotechnology in the Negev, Ben-Gurion University of the Negev, Beer-Sheva, Israel
| | - L Valinsky
- Central Laboratories, Public Health Services, Ministry of Health, Jerusalem, Israel
| | - S Jarraud
- CIRI, Centre International de Recherche en Infectiologie, Legionella Pathogenesis Team, Univ Lyon, Inserm, U1111, Université Claude Bernard Lyon 1, CNRS, UMR5308, ENS de Lyon, F-69007, Lyon, France; National Reference Centre of Legionella, Institute of Infectious Agents, Hospices Civils de Lyon, Lyon, France; ESCMID Study Group for Legionella Infections (ESGLI), Basel, Switzerland
| | - J Moran-Gilad
- ESCMID Study Group for Legionella Infections (ESGLI), Basel, Switzerland; School of Public Health, Faculty of Health Sciences, Ben-Gurion University of the Negev. Beer-Sheva, Israel; Public Health Services, Ministry of Health, Jerusalem, Israel.
| | | |
Collapse
|
4
|
Sharaby Y, Rodríguez-Martínez S, Höfle MG, Brettar I, Halpern M. Quantitative microbial risk assessment of Legionella pneumophila in a drinking water supply system in Israel. THE SCIENCE OF THE TOTAL ENVIRONMENT 2019; 671:404-410. [PMID: 30933796 DOI: 10.1016/j.scitotenv.2019.03.287] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/20/2019] [Revised: 03/13/2019] [Accepted: 03/19/2019] [Indexed: 06/09/2023]
Abstract
Legionella pneumophila cause human infections via inhalation of contaminated water aerosols, resulting in severe pneumonia. Legionella spp. prevalence was monitored in a drinking-water distribution system (DWDS) in Northern Israel. Five points (toilet faucets and showers) were sampled seasonally along a three years period. Toilet faucets and shower use, both generating aerosols, are known transmission routes for this pathogen and thus, present a potential health risk. Quantitative Microbial Risk Assessment (QMRA) was applied in order to assess the health risks posed by Legionella for these two exposure scenarios, while considering Legionella seasonality. The obtained results were compared with estimated tolerable risk levels of infection and of disease set by the USEPA and WHO. Both limits were expressed as Disability-Adjusted Life Years index (DALY) being 1 × 10-4 and 1 × 10-6, respectively. The QMRA revealed that the annual risk levels for both faucets and showers use exceeded the acceptable risk of infection with an average of 5.52 × 10-4 and 2.37 × 10-3 DALY'S per person per year, respectively. Annual risk levels were stable with no significant differences between the three years. Risk levels varied significantly between seasons by up to three orders of magnitude. Risk levels were highest during summer, autumn, and lowest during winter. The highest seasonal infection risk values were found in summer for both faucets and showers, which corresponded to 8.09 × 10-4 and 2.75 × 10-3 DALY'S per person per year, respectively. In conclusion, during summer and autumn there is a significant increase of the infection risk associated with exposure to Legionella-contaminated aerosols, in the studied water system. Public health assessment and prevention measures should focus on these seasons.
Collapse
Affiliation(s)
- Y Sharaby
- Department of Evolutionary and Environmental Biology, Faculty of Natural Sciences, University of Haifa, Haifa, Israel.
| | - S Rodríguez-Martínez
- Department of Evolutionary and Environmental Biology, Faculty of Natural Sciences, University of Haifa, Haifa, Israel
| | - M G Höfle
- Department of Vaccinology and Applied Microbiology, Helmholtz Centre for Infection Research (HZI), Braunschweig, Germany
| | - I Brettar
- Department of Vaccinology and Applied Microbiology, Helmholtz Centre for Infection Research (HZI), Braunschweig, Germany
| | - M Halpern
- Department of Evolutionary and Environmental Biology, Faculty of Natural Sciences, University of Haifa, Haifa, Israel; Department of Biology and Environment, Faculty of Natural Sciences, University of Haifa, Oranim, Tivon, Israel
| |
Collapse
|
5
|
Comparison of in situ sequence type analysis of Legionella pneumophila in respiratory tract secretions and environmental samples of a hospital in East Jerusalem. Epidemiol Infect 2018; 146:2116-2121. [PMID: 30157982 DOI: 10.1017/s0950268818002340] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
Legionella pneumophila genotyping is important for epidemiological investigation of nosocomial and community-acquired outbreaks of legionellosis. The prevalence of legionellosis in pneumonia patients in the West Bank was monitored for the first time, and the sequence types (STs) from respiratory samples were compared with STs of environmental samples from different wards of the hospital. Sputum (n = 121) and bronchoalveolar lavage (BAL) (n = 74) specimens were cultured for L. pneumophila; genomic DNA was tested by 16S rRNA polymerase chain reaction (PCR) amplification. Nested PCR sequence-based typing (NPSBT) was implemented on DNA of the respiratory and environmental PCR-positive samples. Only one respiratory specimen was positive for L. pneumophila by culture. BAL gave a higher percentage of L. pneumophila-positive samples, 35% (26/74) than sputum, 15% (18/121) by PCR. NPSBT revealed the following STs: ST 1 (29%, 7/24), ST 461 (21%, 5/24), ST 1037 (4%, 1/24) from respiratory samples, STs from environmental samples: ST 1 (28.5%, 4/14), ST 187 (21.4%, 3/14) and ST 2070, ST 461, ST 1482 (7.1%, 1/14) each. This study emphasises the advantage of PCR over culture for the detection of L. pneumophila in countries where antibiotics are indiscriminately used prior to hospital admission. ST 1 was the predominant ST in both respiratory and environmental samples.
Collapse
|
6
|
Community acquired pneumonia by Legionella pneumophila: Study of 136 cases. Med Clin (Barc) 2018; 151:265-269. [PMID: 29705157 DOI: 10.1016/j.medcli.2018.03.011] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2017] [Revised: 03/07/2018] [Accepted: 03/08/2018] [Indexed: 01/27/2023]
Abstract
OBJECTIVE Most of the data on Legionella pneumonia in our country come from the Mediterranean area, and there are few studies from the Northwest area. This study tries to assess the situation of this infection in this area. METHOD Retrospective study of all patients with positive Legionella antigenuria treated at the University Hospital Lucus Augusti in Lugo (Spain) from 2001, the year in which this test was introduced in our centre, until 2015. We analysed epidemiological data, risk factors, clinical, radiological and biochemical findings, and clinical outcome. RESULTS The sampled included 136 patients. When comparing the first five years of the study with the last five, the incidence increased from 10.9 to 64.5 cases/1,000,000; the number of antigenuria requests increased 3.4 times, and compared to other pneumonia aetiologies Legionella increased from 0.9% to 15%. The mean age was 64.1years and 84.6% were males; 74.3% had comorbidities. Males were significantly younger (62.7±16.6 vs 71.9±17.3) and consumed more alcohol (26.1% vs 0%) and tobacco (67.8% vs 14.3%). Diagnosis was established within the first 72hours in 88.9% of cases and most received levofloxacin (95.6%). Hospitalisation was needed in 85% of cases, 11.7% in ICU and 4.4% died. CONCLUSIONS After the introduction of antigenuria there was an increase in the incidence of Legionella pneumonia recorded in our health area. Its rate in recent years has been one of the highest in our country. Despite the fact that the patients had advanced age and comorbidities, mortality was low.
Collapse
|
7
|
Prevalence of Infection-Competent Serogroup 6 Legionella pneumophila within Premise Plumbing in Southeast Michigan. mBio 2018; 9:mBio.00016-18. [PMID: 29437918 PMCID: PMC5801461 DOI: 10.1128/mbio.00016-18] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
Abstract
Coinciding with major changes to its municipal water system, Flint, MI, endured Legionnaires’ disease outbreaks in 2014 and 2015. By sampling premise plumbing in Flint in the fall of 2016, we found that 12% of homes harbored legionellae, a frequency similar to that in residences in neighboring areas. To evaluate the genetic diversity of Legionella pneumophila in Southeast Michigan, we determined the sequence type (ST) and serogroup (SG) of the 18 residential isolates from Flint and Detroit, MI, and the 33 clinical isolates submitted by hospitals in three area counties in 2013 to 2016. Common to one environmental and four clinical samples were strains of L. pneumophila SG1 and ST1, the most prevalent ST worldwide. Among the Flint premise plumbing isolates, 14 of 16 strains were of ST367 and ST461, two closely related SG6 strain types isolated previously from patients and corresponding environmental samples. Each of the representative SG1 clinical strains and SG6 environmental isolates from Southeast Michigan infected and survived within macrophage cultures at least as well as a virulent laboratory strain, as judged by microscopy and by enumerating CFU. Likewise, 72 h after infection, the yield of viable-cell counts increased >100-fold for each of the representative SG1 clinical isolates, Flint premise plumbing SG6 ST367 and -461 isolates, and two Detroit residential isolates. We verified by immunostaining that SG1-specific antibody does not cross-react with the SG6 L. pneumophila environmental strains. Because the widely used urinary antigen diagnostic test does not readily detect non-SG1 L. pneumophila, Legionnaires’ disease caused by SG6 L. pneumophila is likely underreported worldwide. L. pneumophila is the leading cause of disease outbreaks associated with drinking water in the United States. Compared to what is known of the established risks of colonization within hospitals and hotels, relatively little is known about residential exposure to L. pneumophila. One year after two outbreaks of Legionnaires’ disease in Genesee County, MI, that coincided with damage to the Flint municipal water system, our multidisciplinary team launched an environmental surveillance and laboratory research campaign aimed at informing risk management strategies to provide safe public water supplies. The most prevalent L. pneumophila strains isolated from residential plumbing were closely related strains of SG6. In laboratory tests of virulence, the SG6 environmental isolates resembled SG1 clinical strains, yet they are not readily detected by the common diagnostic urinary antigen test, which is specific for SG1. Therefore, our study complements the existing epidemiological literature indicating that Legionnaires’ disease due to non-SG1 strains is underreported around the globe.
Collapse
|
8
|
Blanky M, Sharaby Y, Rodríguez-Martínez S, Halpern M, Friedler E. Greywater reuse - Assessment of the health risk induced by Legionella pneumophila. WATER RESEARCH 2017; 125:410-417. [PMID: 28889040 DOI: 10.1016/j.watres.2017.08.068] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2017] [Revised: 08/20/2017] [Accepted: 08/25/2017] [Indexed: 06/07/2023]
Abstract
Greywater (GW), domestic wastewater excluding the streams generated by toilets and kitchens, can serve as an alternative water source. The main options for GW reuse are toilet flushing and garden irrigation, both generating aerosols. These may transmit inhalable pathogens like Legionella and present a potential health risk. This study quantified the health risk that may arise from inhalation of Legionella-contaminated aerosols due to non-potable GW reuse. Data on Legionella concentrations in potable water and GW was collected. Then, Quantitative Microbial Risk Assessment (QMRA) was performed for two possible exposure scenarios: garden irrigation and toilet flushing. This was performed while considering Legionella seasonality. In order to determine the safety of GW reuse regarding Legionella transmission, the obtained results were compared with estimated tolerable risk levels of infection and of disease. Both limits were expressed as Disability-Adjusted Life Years index (DALY) being 10-4 and 10-5, respectively. The QMRA revealed that the annual risk associated with reuse of treated and chlorinated GW for garden irrigation and toilet flushing was not significantly higher than the risk associated with using potable water for the same two purposes. In all studied scenarios, the health risk stemming from reusing treated and chlorinated GW was acceptable regarding Legionella infection. In contrast, reuse of untreated or treated but unchlorinated GW should not be practiced, as these are associated with significantly higher health risks.
Collapse
Affiliation(s)
- Marina Blanky
- Faculty of Civil and Environmental Engineering, Technion, Haifa, Israel
| | - Yehonatan Sharaby
- Department of Evolutionary and Environmental Biology, Faculty of Natural Sciences, University of Haifa, Haifa, Israel
| | - Sara Rodríguez-Martínez
- Department of Evolutionary and Environmental Biology, Faculty of Natural Sciences, University of Haifa, Haifa, Israel
| | - Malka Halpern
- Department of Evolutionary and Environmental Biology, Faculty of Natural Sciences, University of Haifa, Haifa, Israel; Department of Biology and Environment, Faculty of Natural Sciences, University of Haifa, Oranim, Tivon, Israel.
| | - Eran Friedler
- Faculty of Civil and Environmental Engineering, Technion, Haifa, Israel
| |
Collapse
|
9
|
Burillo A, Pedro-Botet ML, Bouza E. Microbiology and Epidemiology of Legionnaire's Disease. Infect Dis Clin North Am 2017; 31:7-27. [PMID: 28159177 DOI: 10.1016/j.idc.2016.10.002] [Citation(s) in RCA: 63] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Legionnaire's disease (LD) is the pneumonic form of legionellosis caused by aerobic gram-negative bacilli of the genus Legionella. Individuals become infected when they inhale aerosolized water droplets contaminated with Legionella species. Forty years after the identification of Legionella pneumophila as the cause of the 1976 pneumonia outbreak in a hotel in Philadelphia, we have non-culture-based diagnostic tests, effective antibiotics, and preventive measures to handle LD. With a mortality rate still around 10%, underreporting, and sporadic outbreaks, there is still much work to be done. In this article, the authors review the microbiology, laboratory diagnosis, and epidemiology of LD.
Collapse
Affiliation(s)
- Almudena Burillo
- Division of Clinical Microbiology and Infectious Diseases, Hospital General Universitario Gregorio Marañón, Doctor Esquerdo 46, 28007 Madrid, Spain; Instituto de Investigación Sanitaria Gregorio Marañón, Doctor Esquerdo 46, 28007 Madrid, Spain; Departamento de Medicina, Facultad de Medicina, Universidad Complutense de Madrid, Plaza Ramón y Cajal s/n, 28040 Madrid, Spain
| | - María Luisa Pedro-Botet
- Infectious Diseases Unit, Hospital Universitario German Trías i Pujol, Carretera de Canyet s/n, 08916 Badalona, Spain; Departamento de Medicina, Area de Medicina, Universidad Autónoma de Barcelona, Plaza Cívica, Campus de la UAB, 08193 Bellaterra, Sardañola del Vallés (Barcelona), Spain; CIBER de Enfermedades Respiratorias (CIBERES CB06/06/1089), Instituto de Salud Carlos III, Monforte de Lemos 3-5, Pabellón 11, 28029 Madrid, Spain
| | - Emilio Bouza
- Division of Clinical Microbiology and Infectious Diseases, Hospital General Universitario Gregorio Marañón, Doctor Esquerdo 46, 28007 Madrid, Spain; Instituto de Investigación Sanitaria Gregorio Marañón, Doctor Esquerdo 46, 28007 Madrid, Spain; Departamento de Medicina, Facultad de Medicina, Universidad Complutense de Madrid, Plaza Ramón y Cajal s/n, 28040 Madrid, Spain; CIBER de Enfermedades Respiratorias (CIBERES CB06/06/0058), Instituto de Salud Carlos III, Monforte de Lemos 3-5, Pabellón 11, 28029 Madrid, Spain.
| |
Collapse
|
10
|
Mizrahi H, Peretz A, Lesnik R, Aizenberg-Gershtein Y, Rodríguez-Martínez S, Sharaby Y, Pastukh N, Brettar I, Höfle MG, Halpern M. Comparison of sputum microbiome of legionellosis-associated patients and other pneumonia patients: indications for polybacterial infections. Sci Rep 2017; 7:40114. [PMID: 28059171 PMCID: PMC5216348 DOI: 10.1038/srep40114] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2016] [Accepted: 12/02/2016] [Indexed: 02/08/2023] Open
Abstract
Bacteria of the genus Legionella cause water-based infections resulting in severe pneumonia. Here we analyze and compare the bacterial microbiome of sputum samples from pneumonia patients in relation to the presence and abundance of the genus Legionella. The prevalence of Legionella species was determined by culture, PCR, and Next Generation Sequencing (NGS). Nine sputum samples out of the 133 analyzed were PCR-positive using Legionella genus-specific primers. Only one sample was positive by culture. Illumina MiSeq 16S rRNA gene sequencing analyses of Legionella-positive and Legionella-negative sputum samples, confirmed that indeed, Legionella was present in the PCR-positive sputum samples. This approach allowed the identification of the sputum microbiome at the genus level, and for Legionella genus at the species and sub-species level. 42% of the sputum samples were dominated by Streptococcus. Legionella was never the dominating genus and was always accompanied by other respiratory pathogens. Interestingly, sputum samples that were Legionella positive were inhabited by aquatic bacteria that have been observed in an association with amoeba, indicating that amoeba might have transferred Legionella from the drinking water together with its microbiome. This is the first study that demonstrates the sputum major bacterial commensals and pathogens profiles with regard to Legionella presence.
Collapse
Affiliation(s)
- Hila Mizrahi
- Department of Evolutionary and Environmental Biology, Faculty of Natural Sciences, University of Haifa, Mount Carmel, Haifa, Israel
- Microbiology Lab, Baruch Padeh Medical Center, Poriya, affiliated with the Faculty of Medicine, Bar Ilan University, Israel
| | - Avi Peretz
- Microbiology Lab, Baruch Padeh Medical Center, Poriya, affiliated with the Faculty of Medicine, Bar Ilan University, Israel
| | - René Lesnik
- Department of Vaccinology and Applied Microbiology, Helmholtz Centre for Infection Research (HZI), Braunschweig, Germany
| | - Yana Aizenberg-Gershtein
- Department of Evolutionary and Environmental Biology, Faculty of Natural Sciences, University of Haifa, Mount Carmel, Haifa, Israel
| | - Sara Rodríguez-Martínez
- Department of Evolutionary and Environmental Biology, Faculty of Natural Sciences, University of Haifa, Mount Carmel, Haifa, Israel
| | - Yehonatan Sharaby
- Department of Evolutionary and Environmental Biology, Faculty of Natural Sciences, University of Haifa, Mount Carmel, Haifa, Israel
| | - Nina Pastukh
- Microbiology Lab, Baruch Padeh Medical Center, Poriya, affiliated with the Faculty of Medicine, Bar Ilan University, Israel
| | - Ingrid Brettar
- Department of Vaccinology and Applied Microbiology, Helmholtz Centre for Infection Research (HZI), Braunschweig, Germany
| | - Manfred G. Höfle
- Department of Vaccinology and Applied Microbiology, Helmholtz Centre for Infection Research (HZI), Braunschweig, Germany
| | - Malka Halpern
- Department of Evolutionary and Environmental Biology, Faculty of Natural Sciences, University of Haifa, Mount Carmel, Haifa, Israel
- Department of Biology and Environment, Faculty of Natural Sciences, University of Haifa, Oranim, Tivon, Israel
| |
Collapse
|
11
|
Khodr A, Kay E, Gomez-Valero L, Ginevra C, Doublet P, Buchrieser C, Jarraud S. Molecular epidemiology, phylogeny and evolution of Legionella. INFECTION GENETICS AND EVOLUTION 2016; 43:108-22. [PMID: 27180896 DOI: 10.1016/j.meegid.2016.04.033] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2016] [Revised: 04/29/2016] [Accepted: 04/30/2016] [Indexed: 12/12/2022]
Abstract
Legionella are opportunistic pathogens that develop in aquatic environments where they multiply in protozoa. When infected aerosols reach the human respiratory tract they may accidentally infect the alveolar macrophages leading to a severe pneumonia called Legionnaires' disease (LD). The ability of Legionella to survive within host-cells is strictly dependent on the Dot/Icm Type 4 Secretion System that translocates a large repertoire of effectors into the host cell cytosol. Although Legionella is a large genus comprising nearly 60 species that are worldwide distributed, only about half of them have been involved in LD cases. Strikingly, the species Legionella pneumophila alone is responsible for 90% of all LD cases. The present review summarizes the molecular approaches that are used for L. pneumophila genotyping with a major focus on the contribution of whole genome sequencing (WGS) to the investigation of local L. pneumophila outbreaks and global epidemiology studies. We report the newest knowledge regarding the phylogeny and the evolution of Legionella and then focus on virulence evolution of those Legionella species that are known to have the capacity to infect humans. Finally, we discuss the evolutionary forces and adaptation mechanisms acting on the Dot/Icm system itself as well as the role of mobile genetic elements (MGE) encoding T4ASSs and of gene duplications in the evolution of Legionella and its adaptation to different hosts and lifestyles.
Collapse
Affiliation(s)
- A Khodr
- Institut Pasteur, Unité de Biologie des Bactéries Intracellulaires, France; CNRS, UMR 3525, 28, Rue du Dr Roux, 75724 Paris, France
| | - E Kay
- CIRI, International Center for Infectiology Research, Inserm, U1111, CNRS, UMR 5308, Université Lyon 1, École Normale Supérieure de Lyon, Lyon F-69008, France
| | - L Gomez-Valero
- Institut Pasteur, Unité de Biologie des Bactéries Intracellulaires, France; CNRS, UMR 3525, 28, Rue du Dr Roux, 75724 Paris, France
| | - C Ginevra
- CIRI, International Center for Infectiology Research, Inserm, U1111, CNRS, UMR 5308, Université Lyon 1, École Normale Supérieure de Lyon, Lyon F-69008, France; French National Reference Center of Legionella, Institut des agents infectieux, Hospices Civils de Lyon, Lyon, France
| | - P Doublet
- CIRI, International Center for Infectiology Research, Inserm, U1111, CNRS, UMR 5308, Université Lyon 1, École Normale Supérieure de Lyon, Lyon F-69008, France
| | - C Buchrieser
- Institut Pasteur, Unité de Biologie des Bactéries Intracellulaires, France; CNRS, UMR 3525, 28, Rue du Dr Roux, 75724 Paris, France
| | - S Jarraud
- CIRI, International Center for Infectiology Research, Inserm, U1111, CNRS, UMR 5308, Université Lyon 1, École Normale Supérieure de Lyon, Lyon F-69008, France; French National Reference Center of Legionella, Institut des agents infectieux, Hospices Civils de Lyon, Lyon, France
| |
Collapse
|
12
|
Levcovich A, Lazarovitch T, Moran-Gilad J, Peretz C, Yakunin E, Valinsky L, Weinberger M. Complex clinical and microbiological effects on Legionnaires' disease outcone; A retrospective cohort study. BMC Infect Dis 2016; 16:75. [PMID: 26864322 PMCID: PMC4748635 DOI: 10.1186/s12879-016-1374-9] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2015] [Accepted: 01/22/2016] [Indexed: 01/21/2023] Open
Abstract
BACKGROUND Legionnaires' disease (LD) is associated with high mortality rates and poses a diagnostic and therapeutic challenge. Use of the rapid urinary antigen test (UAT) has been linked to improved outcome. We examined the association between the method of diagnosis (UAT or culture) and various clinical and microbiological characteristics and outcome of LD. METHODS Consecutive patients with pneumonia and confirmation of Legionella infection by a positive UAT and/or a positive culture admitted between the years 2006-2012 to a university hospital were retrospectively studied. Isolated L. pneumophila strains were subject to serogrouping, immunological subtyping and sequence-based typing. Variables associated with 30-day all-cause mortality were analyzed using logistic regression as well as cox regression. RESULTS Seventy-two patients were eligible for mortality analyses (LD study group), of whom 15.5 % have died. Diagnosis based on positive L. pneumophila UAT as compared to positive culture (OR = 0.18, 95 % CI 0.03-0.98, p = 0.05) and administration of appropriate antibiotic therapy within 2 hospitalization days as compared to delayed therapy (OR = 0.16, 95 % CI 0.03-0.90, p = 0.04) were independently associated with reduced mortality. When controlling for intensive care unit (ICU) admissions, the method of diagnosis became non-significant. Survival analyses showed a significantly increased death risk for patients admitted to ICU compared to others (HR 12.90, 95 % CI 2.78-59.86, p = 0.001) and reduced risk for patients receiving appropriate antibiotic therapy within the first two admissions days compared to delayed therapy (HR 0.13, 95 % CI 0.04-0.05, p = 0.001). Legionella cultures were positive in 35 patients (including 29 patients from the LD study group), of whom 65.7 % were intubated and 37.1 % have died. Sequence type (ST) ST1 accounted for 50.0 % of the typed cases and ST1, OLDA/Oxford was the leading phenon (53.8 %). Mortality rate among patients in the LD study group infected with ST1 was 18.2 % compared to 42.9 % for non-ST1 genotypes (OR = 0.30, 95 % CI 0.05-1.91, p = 0.23). CONCLUSIONS The study confirms the importance of early administration of appropriate antibiotic therapy and at the same time highlights the complex associations of different diagnostic approaches with LD outcome. Infection with ST1 was not associated with increased mortality. Genotype effects on outcome mandate examination in larger cohorts.
Collapse
Affiliation(s)
- Ariela Levcovich
- Infectious Diseases Unit, Assaf Harofeh Medical Center, Zerifin, 70300, Israel.
| | - Tsilia Lazarovitch
- Microbiology Laboratory, Assaf Harofeh Medical Center, Zerifin, 70300, Israel.
| | - Jacob Moran-Gilad
- National Program for Legionellosis Control and Public Health Services, Israeli Ministry of Health, 39 Yermiyahu St., 5th Floor, Jerusalem, Israel.
- ESCMID Study Group for Legionella Infections (ESGLI), Basel, Switzerland.
- Faculty of Health Sciences, Ben-Gurion University of the Negev. Ben-Gurion Boulevard, Beer-Sheva, Israel.
| | - Chava Peretz
- School of Public Health, Epidemiology, Sackler School of Medicine, Tel Aviv University, POB 39040, Tel Aviv, 69978, Israel.
| | - Eugenia Yakunin
- Molecular Laboratory, Central Laboratories, Israel Ministry of Health, POB 34410, Jerusalem, 94467, Israel.
| | - Lea Valinsky
- Molecular Laboratory, Central Laboratories, Israel Ministry of Health, POB 34410, Jerusalem, 94467, Israel.
| | - Miriam Weinberger
- Infectious Diseases Unit, Assaf Harofeh Medical Center, Zerifin, 70300, Israel.
- Sackler School of Medicine, Tel Aviv University, POB 39040, Tel Aviv, 69978, Israel.
| |
Collapse
|
13
|
Moran-Gilad J, Prior K, Yakunin E, Harrison TG, Underwood A, Lazarovitch T, Valinsky L, Lück C, Krux F, Agmon V, Grotto I, Harmsen D. Design and application of a core genome multilocus sequence typing scheme for investigation of Legionnaires' disease incidents. Euro Surveill 2015. [DOI: 10.2807/1560-7917.es2015.20.28.21186] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
Binary file ES_Abstracts_Final_ECDC.txt matches
Collapse
Affiliation(s)
- J Moran-Gilad
- Public Health Services, Ministry of Health, Jerusalem, Israel
- Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheva, Israel
- Surveillance and Pathogenomics Israeli Centre of Excellence, National Institute for Biotechnology in the Negev, Ben-Gurion University of the Negev, Beer-Sheva, Israel
| | - K Prior
- Department of Periodontology, University of Münster, Münster, Germany
| | - E Yakunin
- Central Laboratories, Public Health Services, Ministry of Health, Jerusalem, Israel
| | - T G Harrison
- Reference Microbiology Services, Public Health England, London, United Kingdom
| | - A Underwood
- Reference Microbiology Services, Public Health England, London, United Kingdom
| | - T Lazarovitch
- Department of Clinical Microbiology, Assaf Harofeh Medical Centre, Zerifin, Israel
| | - L Valinsky
- Central Laboratories, Public Health Services, Ministry of Health, Jerusalem, Israel
| | - C Lück
- Institute of Medical Microbiology and Hygiene, University of Technology, Dresden, Germany
| | - F Krux
- Department of Periodontology, University of Münster, Münster, Germany
| | - V Agmon
- Central Laboratories, Public Health Services, Ministry of Health, Jerusalem, Israel
| | - I Grotto
- Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheva, Israel
- Public Health Services, Ministry of Health, Jerusalem, Israel
| | - D Harmsen
- Department of Periodontology, University of Münster, Münster, Germany
| |
Collapse
|
14
|
Rodríguez-Martínez S, Sharaby Y, Pecellín M, Brettar I, Höfle M, Halpern M. Spatial distribution of Legionella pneumophila MLVA-genotypes in a drinking water system. WATER RESEARCH 2015; 77:119-132. [PMID: 25864003 DOI: 10.1016/j.watres.2015.03.010] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2014] [Revised: 03/10/2015] [Accepted: 03/12/2015] [Indexed: 06/04/2023]
Abstract
Bacteria of the genus Legionella cause water-based infections, resulting in severe pneumonia. To improve our knowledge about Legionella spp. ecology, its prevalence and its relationships with environmental factors were studied. Seasonal samples were taken from both water and biofilm at seven sampling points of a small drinking water distribution system in Israel. Representative isolates were obtained from each sample and identified to the species level. Legionella pneumophila was further determined to the serotype and genotype level. High resolution genotyping of L. pneumophila isolates was achieved by Multiple-Locus Variable number of tandem repeat Analysis (MLVA). Within the studied water system, Legionella plate counts were higher in summer and highly variable even between adjacent sampling points. Legionella was present in six out of the seven selected sampling points, with counts ranging from 1.0 × 10(1) to 5.8 × 10(3) cfu/l. Water counts were significantly higher in points where Legionella was present in biofilms. The main fraction of the isolated Legionella was L. pneumophila serogroup 1. Serogroup 3 and Legionella sainthelensis were also isolated. Legionella counts were positively correlated with heterotrophic plate counts at 37 °C and negatively correlated with chlorine. Five MLVA-genotypes of L. pneumophila were identified at different buildings of the sampled area. The presence of a specific genotype, "MLVA-genotype 4", consistently co-occurred with high Legionella counts and seemed to "trigger" high Legionella counts in cold water. Our hypothesis is that both the presence of L. pneumophila in biofilm and the presence of specific genotypes, may indicate and/or even lead to high Legionella concentration in water. This observation deserves further studies in a broad range of drinking water systems to assess its potential for general use in drinking water monitoring and management.
Collapse
Affiliation(s)
- Sarah Rodríguez-Martínez
- Department of Evolutionary and Environmental Biology, Faculty of Natural Sciences, University of Haifa, Haifa, Israel
| | - Yehonatan Sharaby
- Department of Evolutionary and Environmental Biology, Faculty of Natural Sciences, University of Haifa, Haifa, Israel
| | - Marina Pecellín
- Department of Vaccinology and Applied Microbiology, Helmholtz Centre for Infection Research (HZI), Braunschweig, Germany
| | - Ingrid Brettar
- Department of Vaccinology and Applied Microbiology, Helmholtz Centre for Infection Research (HZI), Braunschweig, Germany
| | - Manfred Höfle
- Department of Vaccinology and Applied Microbiology, Helmholtz Centre for Infection Research (HZI), Braunschweig, Germany
| | - Malka Halpern
- Department of Evolutionary and Environmental Biology, Faculty of Natural Sciences, University of Haifa, Haifa, Israel; Department of Biology and Environment, Faculty of Natural Sciences, University of Haifa, Oranim, Tivon, Israel.
| |
Collapse
|
15
|
Mercante JW, Winchell JM. Current and emerging Legionella diagnostics for laboratory and outbreak investigations. Clin Microbiol Rev 2015; 28:95-133. [PMID: 25567224 PMCID: PMC4284297 DOI: 10.1128/cmr.00029-14] [Citation(s) in RCA: 217] [Impact Index Per Article: 24.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
Legionnaires' disease (LD) is an often severe and potentially fatal form of bacterial pneumonia caused by an extensive list of Legionella species. These ubiquitous freshwater and soil inhabitants cause human respiratory disease when amplified in man-made water or cooling systems and their aerosols expose a susceptible population. Treatment of sporadic cases and rapid control of LD outbreaks benefit from swift diagnosis in concert with discriminatory bacterial typing for immediate epidemiological responses. Traditional culture and serology were instrumental in describing disease incidence early in its history; currently, diagnosis of LD relies almost solely on the urinary antigen test, which captures only the dominant species and serogroup, Legionella pneumophila serogroup 1 (Lp1). This has created a diagnostic "blind spot" for LD caused by non-Lp1 strains. This review focuses on historic, current, and emerging technologies that hold promise for increasing LD diagnostic efficiency and detection rates as part of a coherent testing regimen. The importance of cooperation between epidemiologists and laboratorians for a rapid outbreak response is also illustrated in field investigations conducted by the CDC with state and local authorities. Finally, challenges facing health care professionals, building managers, and the public health community in combating LD are highlighted, and potential solutions are discussed.
Collapse
Affiliation(s)
- Jeffrey W Mercante
- Pneumonia Response and Surveillance Laboratory, Respiratory Diseases Branch, U.S. Centers for Disease Control and Prevention, Atlanta, Georgia, USA
| | - Jonas M Winchell
- Pneumonia Response and Surveillance Laboratory, Respiratory Diseases Branch, U.S. Centers for Disease Control and Prevention, Atlanta, Georgia, USA
| |
Collapse
|