1
|
Varga NN, Gulyás L, Meznerics FA, Barkovskij-Jakobsen KS, Szabó B, Hegyi P, Bánvölgyi A, Medvecz M, Kiss N. Diagnostic Accuracy of Novel Optical Imaging Techniques for Melanoma Detection: A Systematic Review and Meta-Analysis. Int J Dermatol 2025. [PMID: 40339039 DOI: 10.1111/ijd.17828] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/04/2025] [Revised: 04/14/2025] [Accepted: 04/17/2025] [Indexed: 05/10/2025]
Abstract
The incidence of melanoma is increasing worldwide, requiring early detection to improve survival rates. Although dermoscopy is the standard non-invasive tool for diagnosing melanoma, it relies on experience and skill. Advances in optical imaging technologies and artificial intelligence have the potential to improve diagnostic accuracy. Our objective was to compare the diagnostic accuracy of novel non-invasive optical imaging techniques for melanoma detection. A systematic literature search was conducted in three databases (Medline, Embase, and CENTRAL) on November 15, 2023. Inclusion criteria focused on studies comparing the accuracy of optical imaging methods against histopathology. Outcomes consisted of measures of diagnostic accuracy. Random-effects meta-analyses were performed for each method with 95% confidence intervals to summarize all relevant effect sizes. Of the 16,239 records, 141 articles met the inclusion criteria, of which 138 articles were eligible for the meta-analysis. Reflectance confocal microscopy (RCM) and dermoscopy combined with artificial intelligence (DSC + AI) had the highest sensitivity (0.93), with DSC + AI showing higher specificity (0.77 [0.70-0.83]) than RCM (0.749 [0.7475-0.7504]). Multispectral imaging combined with AI also showed high sensitivity (0.92 [0.82-0.97]) and relatively high specificity (0.80 [0.67-0.89]). Standalone dermoscopy exhibited balanced sensitivity (0.87 [0.84-0.90]) and specificity (0.82 [0.78-0.86]). In melanoma diagnosis, both RCM and DSC + AI can serve as second-step optical evaluation methods for suspicious lesions following initial screening with DSC. By maintaining a strong emphasis on multimodal imaging, healthcare providers could improve early detection and outcomes for patients with melanoma.
Collapse
Affiliation(s)
- Noémi Nóra Varga
- Department of Dermatology, Venereology and Dermatooncology, Faculty of Medicine, Semmelweis University, Budapest, Hungary
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| | - Lili Gulyás
- Department of Dermatology, Venereology and Dermatooncology, Faculty of Medicine, Semmelweis University, Budapest, Hungary
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| | - Fanni Adél Meznerics
- Department of Dermatology, Venereology and Dermatooncology, Faculty of Medicine, Semmelweis University, Budapest, Hungary
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| | - Katarina Sofia Barkovskij-Jakobsen
- Department of Dermatology, Venereology and Dermatooncology, Faculty of Medicine, Semmelweis University, Budapest, Hungary
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| | - Bence Szabó
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
- Institute for Translational Medicine, Medical School, University of Pécs, Pécs, Hungary
| | - Péter Hegyi
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
- Institute for Translational Medicine, Medical School, University of Pécs, Pécs, Hungary
- Institute of Pancreatic Diseases, Semmelweis University, Budapest, Hungary
| | - András Bánvölgyi
- Department of Dermatology, Venereology and Dermatooncology, Faculty of Medicine, Semmelweis University, Budapest, Hungary
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| | - Márta Medvecz
- Department of Dermatology, Venereology and Dermatooncology, Faculty of Medicine, Semmelweis University, Budapest, Hungary
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| | - Norbert Kiss
- Department of Dermatology, Venereology and Dermatooncology, Faculty of Medicine, Semmelweis University, Budapest, Hungary
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| |
Collapse
|
2
|
Lee H, Johnson Z, Denton S, Liu N, Akinwande D, Porter E, Kireev D. A non-invasive approach to skin cancer diagnosis via graphene electrical tattoos and electrical impedance tomography. Physiol Meas 2024; 45:055003. [PMID: 38599226 DOI: 10.1088/1361-6579/ad3d26] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Accepted: 04/10/2024] [Indexed: 04/12/2024]
Abstract
Objective.Making up one of the largest shares of diagnosed cancers worldwide, skin cancer is also one of the most treatable. However, this is contingent upon early diagnosis and correct skin cancer-type differentiation. Currently, methods for early detection that are accurate, rapid, and non-invasive are limited. However, literature demonstrating the impedance differences between benign and malignant skin cancers, as well as between different types of skin cancer, show that methods based on impedance differentiation may be promising.Approach.In this work, we propose a novel approach to rapid and non-invasive skin cancer diagnosis that leverages the technologies of difference-based electrical impedance tomography (EIT) and graphene electronic tattoos (GETs).Main results.We demonstrate the feasibility of this first-of-its-kind system using both computational numerical and experimental skin phantom models. We considered variations in skin cancer lesion impedance, size, shape, and position relative to the electrodes and evaluated the impact of using individual and multi-electrode GET (mGET) arrays. The results demonstrate that this approach has the potential to differentiate based on lesion impedance, size, and position, but additional techniques are needed to determine shape.Significance.In this way, the system proposed in this work, which combines both EIT and GET technology, exhibits potential as an entirely non-invasive and rapid approach to skin cancer diagnosis.
Collapse
Affiliation(s)
- Hannah Lee
- Chandra Family Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, TX, United States of America
| | - Zane Johnson
- McKetta Department of Chemical Engineering, The University of Texas at Austin, Austin, TX, United States of America
| | - Spencer Denton
- Chandra Family Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, TX, United States of America
| | - Ning Liu
- Chandra Family Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, TX, United States of America
| | - Deji Akinwande
- Chandra Family Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, TX, United States of America
- Microelectronics Research Center, The University of Texas at Austin, Austin, TX, United States of America
| | - Emily Porter
- Chandra Family Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, TX, United States of America
- Department of Biomedical Engineering, McGill University, Montreal, Canada
| | - Dmitry Kireev
- Chandra Family Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, TX, United States of America
- Microelectronics Research Center, The University of Texas at Austin, Austin, TX, United States of America
- Department of Biomedical Engineering, The University of Massachusetts Amherst, Amherst, MA, United States of America
| |
Collapse
|
3
|
Blundo A, Cignoni A, Banfi T, Ciuti G. Comparative Analysis of Diagnostic Techniques for Melanoma Detection: A Systematic Review of Diagnostic Test Accuracy Studies and Meta-Analysis. Front Med (Lausanne) 2021; 8:637069. [PMID: 33968951 PMCID: PMC8103840 DOI: 10.3389/fmed.2021.637069] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2020] [Accepted: 03/17/2021] [Indexed: 11/24/2022] Open
Abstract
Melanoma has the highest mortality rate among skin cancers, and early-diagnosis is essential to maximize survival rate. The current procedure for melanoma diagnosis is based on dermoscopy, i.e., a qualitative visual inspection of lesions with intrinsic limited diagnostic reliability and reproducibility. Other non-invasive diagnostic techniques may represent valuable solutions to retrieve additional objective information of a lesion. This review aims to compare the diagnostic performance of non-invasive techniques, alternative to dermoscopy, for melanoma detection in clinical settings. A systematic review of the available literature was performed using PubMed, Scopus and Google scholar databases (2010-September 2020). All human, in-vivo, non-invasive studies using techniques, alternative to dermoscopy, for melanoma diagnosis were included with no restriction on the recruited population. The reference standard was histology but dermoscopy was accepted only in case of benign lesions. Attributes of the analyzed studies were compared, and the quality was evaluated using CASP Checklist. For studies in which the investigated technique was implemented as a diagnostic tool (DTA studies), the QUADAS-2 tool was applied. For DTA studies that implemented a melanoma vs. other skin lesions classification task, a meta-analysis was performed reporting the SROC curves. Sixty-two references were included in the review, of which thirty-eight were analyzed using QUADAS-2. Study designs were: clinical trials (13), retrospective studies (10), prospective studies (8), pilot studies (10), multitiered study (1); the remain studies were proof of concept or had undefined study type. Studies were divided in categories based on the physical principle employed by each diagnostic technique. Twenty-nine out of thirty-eight DTA studies were included in the meta-analysis. Heterogeneity of studies' types, testing strategy, and diagnostic task limited the systematic comparison of the techniques. Based on the SROC curves, spectroscopy achieved the best performance in terms of sensitivity (93%, 95% CI 92.8-93.2%) and specificity (85.2%, 95%CI 84.9-85.5%), even though there was high concern regarding robustness of metrics. Reflectance-confocal-microscopy, instead, demonstrated higher robustness and a good diagnostic performance (sensitivity 88.2%, 80.3-93.1%; specificity 65.2%, 55-74.2%). Best practice recommendations were proposed to reduce bias in future DTA studies. Particular attention should be dedicated to widen the use of alternative techniques to conventional dermoscopy.
Collapse
Affiliation(s)
- Alessia Blundo
- The BioRobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy
- Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy
| | - Arianna Cignoni
- The BioRobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy
- Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy
| | - Tommaso Banfi
- The BioRobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy
- Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy
| | - Gastone Ciuti
- The BioRobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy
- Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy
| |
Collapse
|
4
|
Non-Invasive Analysis of Actinic Keratosis before and after Topical Treatment Using a Cold Stimulation and Near-Infrared Spectroscopy. ACTA ACUST UNITED AC 2020; 56:medicina56090482. [PMID: 32967260 PMCID: PMC7560046 DOI: 10.3390/medicina56090482] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2020] [Revised: 09/14/2020] [Accepted: 09/18/2020] [Indexed: 11/17/2022]
Abstract
Background and objectives: The possible evolution of actinic keratoses (AKs) into invasive squamous cell carcinomas (SCC) makes their treatment and monitoring essential. AKs are typically monitored before and after treatment only through a visual analysis, lacking a quantitative measure to determine treatment effectiveness. Near-infrared spectroscopy (NIRS) is a non-invasive measure of the relative change of oxy-hemoglobin and deoxy-hemoglobin (O2Hb and HHb) in tissues. The aim of our study is to determine if a time and frequency analysis of the NIRS signals acquired from the skin lesion before and after a topical treatment can highlight quantitative differences between the AK skin lesion area. Materials and Methods: The NIRS signals were acquired from the skin lesions of twenty-two patients, with the same acquisition protocol: baseline signals, application of an ice pack near the lesion, removal of ice pack and acquisition of vascular recovery. We calculated 18 features from the NIRS signals, and we applied multivariate analysis of variance (MANOVA) to compare differences between the NIRS signals acquired before and after the therapy. Results: The MANOVA showed that the features computed on the NIRS signals before and after treatment could be considered as two statistically separate groups, after the ice pack removal. Conclusions: Overall, the NIRS technique with the cold stimulation may be useful to support non-invasive and quantitative lesion analysis and regression after a treatment. The results provide a baseline from which to further study skin lesions and the effects of various treatments.
Collapse
|
5
|
The past, present, and prospective on UV-VIS-NIR skin photonics and spectroscopy-a wavelength guide. Med Biol Eng Comput 2020; 58:1159-1175. [PMID: 32319030 DOI: 10.1007/s11517-019-02077-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2018] [Accepted: 11/07/2019] [Indexed: 10/24/2022]
Abstract
The study and applications of in vivo skin optics have been openly documented as early as the year 1954, or possibly earlier. To date, challenges in analyzing the complexities of this field remain, with wide scopes requiring more scrutiny. Recent advances in spectroscopic research and multivariate analytics allow a closer look into applications potentially for detecting or monitoring diseases. One of the challenges in this field is in establishing a reference for applications which correspond to certain bandwidths. This article reviews the scope on past research on skin spectroscopy, and the clinical aspects which have or may have applications on disease detection or enhancing diagnostics. A summary is supplied on the technicalities surrounding the measurements reported in literature, focused towards the wavelength-dependent applications in themes central to the respective research. Analytics on the topology of the papers' data cited in this work is also provided for a statistical perspective. In short, this paper strives to immediately inform the reader with possible applications via the spectroscopic devices at hand. Graphical Abstract .
Collapse
|
6
|
Poh AH, Mahamd Adikan FR, Moghavvemi M, Syed Omar SF, Poh K, Mahyuddin MBH, Yan G, Azizah Ariffin MA, Harun SW. Precursors to non-invasive clinical dengue screening: Multivariate signature analysis of in-vivo diffuse skin reflectance spectroscopy on febrile patients in Malaysia. PLoS One 2020; 15:e0228923. [PMID: 32236132 PMCID: PMC7112162 DOI: 10.1371/journal.pone.0228923] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2019] [Accepted: 01/26/2020] [Indexed: 11/18/2022] Open
Abstract
Dengue diagnostics have come a long way. Attempts at breaking away from lab-oriented dengue detection, such as NS1 antigen, IgM or IgG antibodies detection have extensively received numerous coverage. As a result, rapid detection tests (RDTs) have started to gain inroads in medical practice. Rapid detection tests notwithstanding, analysis of blood serum is still a relatively complicated task. This includes the necessity of phlebotomy, centrifugation for blood serum, and other reagent-based tests. Therefore, a non-invasive method of dengue detection was considered. In this study, we present the utility of diffuse reflectance skin spectroscopy (bandwidth of 200-2500nm) on the forearm during the triaging period for dengue screening potential. This is performed with multivariate analysis of 240 triaged febrile/suspected dengue patients. The data is then scrutinized for its clinical validity to be included as either confirmed or probable dengue, or a control group. Based on discriminant analysis of several data normalization models, we can predict the patients' clinical dengue-positivity at ranges of accuracy between ~93-98% depending on mode of the data, with a probably optimal sensitivity and specificity to the clinical diagnosis of ~89% and ~100% respectively. From the outcomes of this study, we recommend further trials with cautious optimism. With these findings, it is hoped that the elusive non-invasive detection of tropical diseases may gain platform in the near future.
Collapse
Affiliation(s)
- Abdul Halim Poh
- Department of Electrical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
- Integrated Lightwave Research Group, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
- Center of Research for Applied Electronics (CRAE), Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
| | - Faisal Rafiq Mahamd Adikan
- Department of Electrical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
- Integrated Lightwave Research Group, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
- * E-mail:
| | - Mahmoud Moghavvemi
- Department of Electrical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
- Center of Research for Applied Electronics (CRAE), Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
- University of Science and Culture, Tehran, Iran
| | - Sharifah Faridah Syed Omar
- Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia
- Infectious Diseases and Medicine, University of Malaya, Kuala Lumpur, Malaysia
| | - Khadijah Poh
- Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia
| | - Mohamad Badrol Hisyam Mahyuddin
- Department of Electrical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
- Photonics Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
| | - Grace Yan
- Integrated Lightwave Research Group, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
| | | | - Sulaiman Wadi Harun
- Department of Electrical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
- Photonics Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
| |
Collapse
|
7
|
Oleneva E, Panchenko A, Khaydukova M, Gubareva E, Bibikova O, Artyushenko V, Legin A, Kirsanov D. In vivo and in vitro application of near-infrared fiber optic probe for Ehrlich carcinoma distinction: Towards the development of real-time tumor margins assessment tool. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2019; 213:12-18. [PMID: 30677734 DOI: 10.1016/j.saa.2019.01.061] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/21/2018] [Revised: 10/26/2018] [Accepted: 01/15/2019] [Indexed: 06/09/2023]
Abstract
This report describes a full-scale experiment on intradermal Ehrlich carcinoma (EC) differentiation in mouse model using NIR spectroscopy in diffuse reflectance mode and chemometric data processing. EC is widely used as an experimental tumor model due to its resemblance with human undifferentiated epithelial tumors and can be applied as a preclinical testing in order to verify the capability of NIR spectroscopy to distinguish cancer from healthy tissues before a clinical research with an aim of creating a new analytical tool for on-line intraoperative tumor margins assessment. The study consists of five steps of NIR spectra measurements: in vivo on the early stage of carcinoma growth; in vivo on the advanced stage of carcinoma growth; in vivo during the surgery; in vitro study of the post-operative materials stored in formalin; in vitro study of the post-operative materials stored in paraffin. It was shown that reliable tumor differentiation with a compact optic fiber probe was possible in all these cases. The classification models were built on two data sets, obtained during in vivo and in vitro measurements; both of them demonstrated 100% specificity and sensitivity.
Collapse
Affiliation(s)
- Ekaterina Oleneva
- Laboratory of Artificial Sensory Systems, ITMO University, 197101, Kronverksky prospect, 49, St. Petersburg, Russia.
| | - Andrey Panchenko
- Laboratory of Carcinogenesis and Aging, FSBI "N.N. Petrov National Medical Research Center of Oncology" of the Ministry of Healthcare of the Russian Federation, 197758, Leningradskaya street, 68, Pesochny, St. Petersburg, Russia
| | - Maria Khaydukova
- Institute of Chemistry, St. Petersburg State University, 199034, Universitetskaya emb., 7-9, St. Petersburg, Russia
| | - Ekaterina Gubareva
- Laboratory of Carcinogenesis and Aging, FSBI "N.N. Petrov National Medical Research Center of Oncology" of the Ministry of Healthcare of the Russian Federation, 197758, Leningradskaya street, 68, Pesochny, St. Petersburg, Russia
| | - Olga Bibikova
- Art photonics GmbH, 12489, Rudower Chaussee, 46, Berlin, Germany
| | | | - Andrey Legin
- Laboratory of Artificial Sensory Systems, ITMO University, 197101, Kronverksky prospect, 49, St. Petersburg, Russia; Institute of Chemistry, St. Petersburg State University, 199034, Universitetskaya emb., 7-9, St. Petersburg, Russia
| | - Dmitry Kirsanov
- Laboratory of Artificial Sensory Systems, ITMO University, 197101, Kronverksky prospect, 49, St. Petersburg, Russia; Institute of Chemistry, St. Petersburg State University, 199034, Universitetskaya emb., 7-9, St. Petersburg, Russia
| |
Collapse
|
8
|
Ferrante di Ruffano L, Takwoingi Y, Dinnes J, Chuchu N, Bayliss SE, Davenport C, Matin RN, Godfrey K, O'Sullivan C, Gulati A, Chan SA, Durack A, O'Connell S, Gardiner MD, Bamber J, Deeks JJ, Williams HC. Computer-assisted diagnosis techniques (dermoscopy and spectroscopy-based) for diagnosing skin cancer in adults. Cochrane Database Syst Rev 2018; 12:CD013186. [PMID: 30521691 PMCID: PMC6517147 DOI: 10.1002/14651858.cd013186] [Citation(s) in RCA: 47] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
BACKGROUND Early accurate detection of all skin cancer types is essential to guide appropriate management and to improve morbidity and survival. Melanoma and cutaneous squamous cell carcinoma (cSCC) are high-risk skin cancers which have the potential to metastasise and ultimately lead to death, whereas basal cell carcinoma (BCC) is usually localised with potential to infiltrate and damage surrounding tissue. Anxiety around missing early curable cases needs to be balanced against inappropriate referral and unnecessary excision of benign lesions. Computer-assisted diagnosis (CAD) systems use artificial intelligence to analyse lesion data and arrive at a diagnosis of skin cancer. When used in unreferred settings ('primary care'), CAD may assist general practitioners (GPs) or other clinicians to more appropriately triage high-risk lesions to secondary care. Used alongside clinical and dermoscopic suspicion of malignancy, CAD may reduce unnecessary excisions without missing melanoma cases. OBJECTIVES To determine the accuracy of CAD systems for diagnosing cutaneous invasive melanoma and atypical intraepidermal melanocytic variants, BCC or cSCC in adults, and to compare its accuracy with that of dermoscopy. SEARCH METHODS We undertook a comprehensive search of the following databases from inception up to August 2016: Cochrane Central Register of Controlled Trials (CENTRAL); MEDLINE; Embase; CINAHL; CPCI; Zetoc; Science Citation Index; US National Institutes of Health Ongoing Trials Register; NIHR Clinical Research Network Portfolio Database; and the World Health Organization International Clinical Trials Registry Platform. We studied reference lists and published systematic review articles. SELECTION CRITERIA Studies of any design that evaluated CAD alone, or in comparison with dermoscopy, in adults with lesions suspicious for melanoma or BCC or cSCC, and compared with a reference standard of either histological confirmation or clinical follow-up. DATA COLLECTION AND ANALYSIS Two review authors independently extracted all data using a standardised data extraction and quality assessment form (based on QUADAS-2). We contacted authors of included studies where information related to the target condition or diagnostic threshold were missing. We estimated summary sensitivities and specificities separately by type of CAD system, using the bivariate hierarchical model. We compared CAD with dermoscopy using (a) all available CAD data (indirect comparisons), and (b) studies providing paired data for both tests (direct comparisons). We tested the contribution of human decision-making to the accuracy of CAD diagnoses in a sensitivity analysis by removing studies that gave CAD results to clinicians to guide diagnostic decision-making. MAIN RESULTS We included 42 studies, 24 evaluating digital dermoscopy-based CAD systems (Derm-CAD) in 23 study cohorts with 9602 lesions (1220 melanomas, at least 83 BCCs, 9 cSCCs), providing 32 datasets for Derm-CAD and seven for dermoscopy. Eighteen studies evaluated spectroscopy-based CAD (Spectro-CAD) in 16 study cohorts with 6336 lesions (934 melanomas, 163 BCC, 49 cSCCs), providing 32 datasets for Spectro-CAD and six for dermoscopy. These consisted of 15 studies using multispectral imaging (MSI), two studies using electrical impedance spectroscopy (EIS) and one study using diffuse-reflectance spectroscopy. Studies were incompletely reported and at unclear to high risk of bias across all domains. Included studies inadequately address the review question, due to an abundance of low-quality studies, poor reporting, and recruitment of highly selected groups of participants.Across all CAD systems, we found considerable variation in the hardware and software technologies used, the types of classification algorithm employed, methods used to train the algorithms, and which lesion morphological features were extracted and analysed across all CAD systems, and even between studies evaluating CAD systems. Meta-analysis found CAD systems had high sensitivity for correct identification of cutaneous invasive melanoma and atypical intraepidermal melanocytic variants in highly selected populations, but with low and very variable specificity, particularly for Spectro-CAD systems. Pooled data from 22 studies estimated the sensitivity of Derm-CAD for the detection of melanoma as 90.1% (95% confidence interval (CI) 84.0% to 94.0%) and specificity as 74.3% (95% CI 63.6% to 82.7%). Pooled data from eight studies estimated the sensitivity of multispectral imaging CAD (MSI-CAD) as 92.9% (95% CI 83.7% to 97.1%) and specificity as 43.6% (95% CI 24.8% to 64.5%). When applied to a hypothetical population of 1000 lesions at the mean observed melanoma prevalence of 20%, Derm-CAD would miss 20 melanomas and would lead to 206 false-positive results for melanoma. MSI-CAD would miss 14 melanomas and would lead to 451 false diagnoses for melanoma. Preliminary findings suggest CAD systems are at least as sensitive as assessment of dermoscopic images for the diagnosis of invasive melanoma and atypical intraepidermal melanocytic variants. We are unable to make summary statements about the use of CAD in unreferred populations, or its accuracy in detecting keratinocyte cancers, or its use in any setting as a diagnostic aid, because of the paucity of studies. AUTHORS' CONCLUSIONS In highly selected patient populations all CAD types demonstrate high sensitivity, and could prove useful as a back-up for specialist diagnosis to assist in minimising the risk of missing melanomas. However, the evidence base is currently too poor to understand whether CAD system outputs translate to different clinical decision-making in practice. Insufficient data are available on the use of CAD in community settings, or for the detection of keratinocyte cancers. The evidence base for individual systems is too limited to draw conclusions on which might be preferred for practice. Prospective comparative studies are required that evaluate the use of already evaluated CAD systems as diagnostic aids, by comparison to face-to-face dermoscopy, and in participant populations that are representative of those in which the test would be used in practice.
Collapse
Key Words
- adult
- humans
- electric impedance
- algorithms
- carcinoma, basal cell
- carcinoma, basal cell/diagnosis
- carcinoma, basal cell/diagnostic imaging
- carcinoma, basal cell/pathology
- carcinoma, squamous cell
- carcinoma, squamous cell/diagnosis
- carcinoma, squamous cell/diagnostic imaging
- carcinoma, squamous cell/pathology
- clinical decision‐making
- dermoscopy
- dermoscopy/methods
- dermoscopy/standards
- diagnosis, computer‐assisted
- diagnosis, computer‐assisted/methods
- diagnosis, computer‐assisted/standards
- false positive reactions
- melanoma
- melanoma/diagnosis
- melanoma/diagnostic imaging
- melanoma/pathology
- sensitivity and specificity
- skin neoplasms
- skin neoplasms/diagnosis
- skin neoplasms/diagnostic imaging
- skin neoplasms/pathology
Collapse
Affiliation(s)
| | - Yemisi Takwoingi
- University of BirminghamInstitute of Applied Health ResearchEdgbaston CampusBirminghamUKB15 2TT
- University Hospitals Birmingham NHS Foundation Trust and University of BirminghamNIHR Birmingham Biomedical Research CentreBirminghamUK
| | - Jacqueline Dinnes
- University of BirminghamInstitute of Applied Health ResearchEdgbaston CampusBirminghamUKB15 2TT
- University Hospitals Birmingham NHS Foundation Trust and University of BirminghamNIHR Birmingham Biomedical Research CentreBirminghamUK
| | - Naomi Chuchu
- University of BirminghamInstitute of Applied Health ResearchEdgbaston CampusBirminghamUKB15 2TT
| | - Susan E Bayliss
- University of BirminghamInstitute of Applied Health ResearchEdgbaston CampusBirminghamUKB15 2TT
| | - Clare Davenport
- University of BirminghamInstitute of Applied Health ResearchEdgbaston CampusBirminghamUKB15 2TT
| | - Rubeta N Matin
- Churchill HospitalDepartment of DermatologyOld RoadHeadingtonOxfordUKOX3 7LE
| | - Kathie Godfrey
- The University of Nottinghamc/o Cochrane Skin GroupNottinghamUK
| | | | - Abha Gulati
- Barts Health NHS TrustDepartment of DermatologyWhitechapelLondonUKE11BB
| | - Sue Ann Chan
- City HospitalBirmingham Skin CentreDudley RdBirminghamUKB18 7QH
| | - Alana Durack
- Addenbrooke’s Hospital, Cambridge University Hospitals NHS Foundation TrustDermatologyHills RoadCambridgeUKCB2 0QQ
| | - Susan O'Connell
- Cardiff and Vale University Health BoardCEDAR Healthcare Technology Research CentreCardiff Medicentre, University Hospital of Wales, Heath Park CampusCardiffWalesUKCF144UJ
| | | | - Jeffrey Bamber
- Institute of Cancer Research and The Royal Marsden NHS Foundation TrustJoint Department of Physics15 Cotswold RoadSuttonUKSM2 5NG
| | - Jonathan J Deeks
- University of BirminghamInstitute of Applied Health ResearchEdgbaston CampusBirminghamUKB15 2TT
- University Hospitals Birmingham NHS Foundation Trust and University of BirminghamNIHR Birmingham Biomedical Research CentreBirminghamUK
| | - Hywel C Williams
- University of NottinghamCentre of Evidence Based DermatologyQueen's Medical CentreDerby RoadNottinghamUKNG7 2UH
| | | | | |
Collapse
|
9
|
Ceder H, Hylén AS, Larkö AMW, Paoli J. Evaluation of electrical impedance spectroscopy as an adjunct to dermoscopy in short-term monitoring of atypical melanocytic lesions. Dermatol Pract Concept 2016; 6:1-6. [PMID: 27867738 PMCID: PMC5108637 DOI: 10.5826/dpc.0604a01] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2016] [Accepted: 07/22/2016] [Indexed: 10/31/2022] Open
Abstract
BACKGROUND Early detection of melanoma is vital for treatment outcome and survival. Short-term sequential digital dermoscopic monitoring (ST-SDDM) involves the capture and assessment of dermoscopic images of one or more atypical melanocytic lesions (AMLs), at baseline and after four months, in order to detect early morphologic changes. Electrical impedance spectroscopy (EIS) is a diagnostic tool with high sensitivity for the detection of malignant melanocytic lesions. OBJECTIVES The aim of this study was to assess whether EIS, in addition to ST-SDDM, could improve the selection of AMLs requiring surgery. METHODS In this retrospective descriptive study, 22 AMLs in 19 patients were monitored with both ST-SDDM and EIS. A modified EIS decision-making algorithm was established. AMLs were excised if any dermoscopic changes were seen and/or if the EIS score had increased significantly at follow-up. Statistical analyses were made including sensitivity, specificity, PPV and NPV. RESULTS A total of seven lesions (32%) were excised. Four lesions (57%) were excised solely because of dermoscopic changes including a 0.4 mm-thick melanoma and three benign nevi. Three benign lesions (43%) were excised because of increased EIS scores without any dermoscopic changes. The EIS scores at follow-up showed high variability as compared to the initial scores. CONCLUSION The addition of EIS to ST-SDDM did not identify additional malignant lesions. There was no correlation between dermoscopic changes seen with ST-SDDM and increased EIS scores. Three histopathologically benign lesions were needlessly excised. Moreover, the low reproducibility and the possible interoperator variability of the method raised concerns.
Collapse
Affiliation(s)
- Hannah Ceder
- Department of Dermatology and Venereology, Sahlgrenska University Hospital and Institute of Clinical Sciences at the Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Alexandra Sjöholm Hylén
- Department of Dermatology and Venereology, Sahlgrenska University Hospital and Institute of Clinical Sciences at the Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Ann-Marie Wennberg Larkö
- Department of Dermatology and Venereology, Sahlgrenska University Hospital and Institute of Clinical Sciences at the Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - John Paoli
- Department of Dermatology and Venereology, Sahlgrenska University Hospital and Institute of Clinical Sciences at the Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| |
Collapse
|
10
|
|
11
|
Shimizu K, Nyström J, Geladi P, Lindholm-Sethson B, Boily JF. Electrolyte ion adsorption and charge blocking effect at the hematite/aqueous solution interface: an electrochemical impedance study using multivariate data analysis. Phys Chem Chem Phys 2015; 17:11560-8. [PMID: 25857599 DOI: 10.1039/c4cp05927a] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
A model-free multivariate analysis using singular value decomposition is employed to refine an equivalent electrical circuit model in order to probe the electrochemical properties of the hematite/water interface in dilute NaCl and NH4Cl solutions using electrochemical impedance spectroscopy. The result shows that the surface protonation is directly related to the mobility and trapping of charge carriers at the mineral surface. Moreover, the point of zero charge can be found at pH where the charge transfer resistance is the highest, in addition to the minimum double layer capacitance. The inner-sphere interaction of the NH4(+) ion with the surface is indicated by an increase of capacitance for charge carrier trapping from the protonated surface as well as lower double layer capacitance and open circuit potential. It is clear that the intrinsic electrochemical activity of hematite depends on the degree of surface (de)protonation and other inner-sphere adsorption, as these processes affect the charge carrier density in the surface state. This work also highlights an important synergistic effect of the two spectral analyses that enables EIS to be utilized in an in-depth investigation of mineral/water interfaces.
Collapse
Affiliation(s)
- K Shimizu
- Department of Chemistry, Umeå University, 90187, Umeå, Sweden.
| | | | | | | | | |
Collapse
|
12
|
Hägerlind E, Falk M, Löfstedt T, Lindholm-Sethson B, Bodén I. Near infrared and skin impedance spectroscopy - a possible support in the diagnostic process of skin tumours in primary health care. Skin Res Technol 2015; 21:493-9. [PMID: 25773339 DOI: 10.1111/srt.12219] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/14/2015] [Indexed: 11/30/2022]
Abstract
BACKGROUND/PURPOSE The global incidence of skin cancer has increased drastically in recent decades, especially in Australia and Northern Europe. Early detection is crucial for good prognosis and high survival rates. In general, primary care physicians have considerably lower sensitivity and specificity rates for detection of skin cancer, compared to dermatologists. A probable main reason for this is that current diagnostic tools are subjective in nature, and therefore diagnostic skills highly depend on experience. Illustratively, in Sweden, approximately 155 500 benign skin lesions are excised unnecessarily every year. An objective instrument, added to the clinical examination, might improve the diagnostic accuracy, and thus promote earlier detection of malignant skin tumours, as well as reduce medical costs associated with unnecessary biopsies and excisions. The general aim of this study was to investigate the usefulness of the combination of near infrared (NIR) and skin impedance spectroscopy as a supportive tool in the diagnosis and evaluation of skin tumours in primary health care. METHODS Near infrared and skin impedance data were collected by performing measurements on suspect malignant, premalignant and benign tumours in the skin of patients seeking primary health care for skin tumour evaluation. The obtained data were analysed using multivariate analysis and compared with the diagnosis received by the conventional diagnostic process. RESULTS The observed sensitivity and specificity rates were both 100%, when discriminating malignant and premalignant skin tumours from benign skin tumours, and the observed sensitivity and specificity for separating malignant skin tumours from premalignant and benign skin tumours were also 100%, respectively. CONCLUSION The results of this study indicate that the NIR and skin impedance spectroscopy may be a useful supportive tool for the general practitioner in the diagnosis and evaluation of skin tumours in primary health care, as a complement to the visual assessment.
Collapse
Affiliation(s)
- E Hägerlind
- Department of Medical and Health Sciences, Division of Community Medicine, Primary Care, Linköping University, Linköping, Sweden
| | - M Falk
- Department of Medical and Health Sciences, Division of Community Medicine, Primary Care, Linköping University, Linköping, Sweden
| | | | | | | |
Collapse
|
13
|
Malvehy J, Hauschild A, Curiel-Lewandrowski C, Mohr P, Hofmann-Wellenhof R, Motley R, Berking C, Grossman D, Paoli J, Loquai C, Olah J, Reinhold U, Wenger H, Dirschka T, Davis S, Henderson C, Rabinovitz H, Welzel J, Schadendorf D, Birgersson U. Clinical performance of the Nevisense system in cutaneous melanoma detection: an international, multicentre, prospective and blinded clinical trial on efficacy and safety. Br J Dermatol 2014; 171:1099-107. [PMID: 24841846 PMCID: PMC4257502 DOI: 10.1111/bjd.13121] [Citation(s) in RCA: 132] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/08/2014] [Indexed: 11/29/2022]
Abstract
BACKGROUND Even though progress has been made, the detection of melanoma still poses a challenge. In light of this situation, the Nevisense electrical impedance spectroscopy (EIS) system (SciBase AB, Stockholm, Sweden) was designed and shown to have the potential to be used as an adjunct diagnostic tool for melanoma detection. OBJECTIVES To assess the effectiveness and safety of the Nevisense system in the distinction of benign lesions of the skin from melanoma with electrical impedance spectroscopy. METHODS This multicentre, prospective, and blinded clinical study was conducted at five American and 17 European investigational sites. All eligible skin lesions in the study were examined with the EIS-based Nevisense system, photographed, removed by excisional biopsy and subjected to histopathological evaluation. A postprocedure clinical follow-up was conducted at 7 ± 3 days from the initial measurement. A total of 1951 patients with 2416 lesions were enrolled into the study; 1943 lesions were eligible and evaluable for the primary efficacy end point, including 265 melanomas - 112 in situ and 153 invasive melanomas with a median Breslow thickness of 0·57 mm [48 basal cell carcinomas (BCCs) and seven squamous cell carcinomas (SCCs)]. RESULTS The observed sensitivity of Nevisense was 96·6% (256 of 265 melanomas) with an exact one-sided 95% lower confidence bound estimated at 94·2% and an observed specificity of 34·4%, and an exact two-sided 95% confidence bound estimated at 32·0-36·9%. The positive and negative predictive values of Nevisense were 21·1% and 98·2%, respectively. The observed sensitivity for nonmelanoma skin cancer was 100% (55 of 48 BCCs and seven SCCs) with an exact two-sided 95% confidence bound estimated at 93·5-100·0%. CONCLUSIONS Nevisense is an accurate and safe device to support clinicians in the detection of cutaneous melanoma.
Collapse
Affiliation(s)
- J Malvehy
- Department of Dermatology, Hospital Clinic, IDIBAPS, University of Barcelona, Barcelona, Spain
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|