1
|
Estrada-Moya F, González-Garay AG, Flores-López A, Serralde-Zúñiga AE. Total and segmental phase angle in a cohort of hospitalised patients with COVID-19: mortality prediction and changes throughout hospitalisation. Br J Nutr 2024; 131:1397-1404. [PMID: 38149452 PMCID: PMC10950452 DOI: 10.1017/s0007114523002994] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Revised: 10/10/2023] [Accepted: 12/13/2023] [Indexed: 12/28/2023]
Abstract
Body composition and phase angle (PhA) have been used to predict mortality in multiple diseases. However, little has been studied regarding segmental measurements, which could potentially help assess subtle changes in specific tissue segments. This study aimed to identify the total PhA cut-off point associated with mortality risk and changes in body composition within a week of hospitalisation in non-critical hospitalised patients with COVID-19. A cohort study was conducted where patients underwent to a complete nutritional assessment upon admission and after seven days, and followed up until hospital discharge or death. A receiver operating characteristic curve was constructed to determine the PhA cut-off point, and the Kaplan–Meier estimator was used to determine survival analysis. Segmental and complete body compositions on admission and after 7 d were compared. We included 110 patients (60 men) with a mean age of 50·5 ± 15·0 years and a median BMI of 28·5 (IQR, 25·6–33·5) kg/m2. The median length of hospital stay was 6 (IQR, 4–9) d, and the mortality rate was 13·6 %. The PhA cut-off point obtained was 4°, with significant differences in the survival rate (P < 0·001) and mortality (HR = 5·81, 95 % CI: 1·80, 18·67, P = 0·003). Segmental and whole-body compositions were negatively affected within one week of hospitalisation, with changes in the approach by the graphical method in both sexes. Nutritional status deteriorates within a week of hospitalisation. PhA < 4° is strongly associated with increased mortality in non-critical hospitalised patients with COVID-19.
Collapse
Affiliation(s)
- Fernando Estrada-Moya
- Servicio de Nutriología Clínica, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Mexico City, Mexico
- Sección de Estudios de Posgrado e Investigación, Instituto Politécnico Nacional “Escuela Superior de Medicina”, Mexico City, Mexico
| | | | - Adriana Flores-López
- Servicio de Nutriología Clínica, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Mexico City, Mexico
| | - Aurora E. Serralde-Zúñiga
- Servicio de Nutriología Clínica, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Mexico City, Mexico
- Facultad de Medicina, Universidad Nacional Autónoma de México, Mexico City, Mexico
| |
Collapse
|
2
|
Petri C, Micheli ML, Izzicupo P, Timperanza N, Lastrucci T, Vanni D, Gulisano M, Mascherini G. Bioimpedance Patterns and Bioelectrical Impedance Vector Analysis (BIVA) of Body Builders. Nutrients 2023; 15:nu15071606. [PMID: 37049446 PMCID: PMC10096811 DOI: 10.3390/nu15071606] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 03/24/2023] [Accepted: 03/24/2023] [Indexed: 03/29/2023] Open
Abstract
Bodybuilders are athletes characterized by high muscle mass. During competitions, the evaluation is performed based on aesthetic parameters. The study aims to provide normative references of body composition with the vector bioimpedance methodology (BIVA). A second aim is to compare BIVA assessments performed on both sides and the upper and lower body. A group of 68 elite bodybuilders (41 males aged 30.1 ± 9.2 years and 27 females aged 32.1 ± 8.0 years) was enrolled. A BIVA assessment was performed the day before the 2021 World Natural Bodybuilding Federation Italian Championships. As a result, male and female bodybuilders ranked to the left in the BIVA ellipse relative to the general population. Furthermore, unlike females, males also ranked lower than the general athletic population. In addition, in the symmetry assessment, males show a significantly greater upper body than the lower, right, and left parts, while in women, this is observed for the lower part of the body. The differences in the results obtained between males and females can be attributed to the different patterns of endocrine production between the sexes and the different criteria used by the juries to attribute the final score during the competitions. Therefore, BIVA references in bodybuilders could help adjust the training and nutritional program during the peak week before a competition.
Collapse
|
3
|
Abstract
The biophysical response of the human body to electric current is widely appreciated as a barometer of fluid distribution and cell function. From distinct raw bioelectrical impedance (BIA) variables assessed in the field of body composition, phase angle (PhA) has been repeatedly indicated as a functional marker of the cell's health and mass. Although resistance training (RT) programs have demonstrated to be effective to improve PhA, with varying degrees of change depending on other raw BIA variables, there is still limited research explaining the biological mechanisms behind these changes. Here, we aim to provide the rationale for the responsiveness of PhA determinants to RT, as well as to summarize all available evidence addressing the effect of varied RT programs on PhA of different age groups. Available data led us to conclude that RT modulates the cell volume by increasing the levels of intracellular glycogen and water, thus triggering structural and functional changes in different cell organelles. These alterations lead, respectively, to shifts in the resistive path of the electric current (resistance, R) and capacitive properties of the human body (reactance, Xc), which ultimately impact PhA, considering that it is the angular transformation of the ratio between Xc and R. Evidence drawn from experimental research suggests that RT is highly effective for enhancing PhA, especially when adopting high-intensity, volume, and duration RT programs combining other types of exercise. Still, additional research exploring the effects of RT on whole-body and regional BIA variables of alternative population groups is recommended for further knowledge development.
Collapse
Affiliation(s)
- Luís B Sardinha
- Exercise and Health Laboratory, Faculdade de Motricidade Humana, CIPER, Universidade de Lisboa, , Cruz Quebrada, Portugal.
| | - Gil B Rosa
- Exercise and Health Laboratory, Faculdade de Motricidade Humana, CIPER, Universidade de Lisboa, , Cruz Quebrada, Portugal
| |
Collapse
|
4
|
Abstract
Measurement of phase angle using bioimpedance analysis (BIA) has become popular as an index of so-called "cellular health". What precisely is meant by this term is not always clear but strong relationships have been found between cellular water status (the relative amounts of extra- and intracellular water), cell membrane integrity and cellular mass. Much of the current research is empirical observation and frequently pays little regard to the underlying biophysical models that underpin the BIA technique or attempts to provide mechanistic explanations for the observations. This brief review seeks to provide a basic understanding of the electrical models frequently used to describe the passive electrical properties of tissues with particular focus on phase angle. In addition, it draws attention to some practical concerns in the measurement of phase angle and notes the additional understanding that can be gained when phase angle are obtained with bioimpedance spectroscopy (BIS) rather than single frequency BIA (SFBIA) along with the potential for simulation modelling.
Collapse
Affiliation(s)
- Leigh C Ward
- School of Chemistry and Molecular Biosciences, The University of Queensland, St Lucia, Brisbane, 4072, Australia.
| | - Steven Brantlov
- Department of Procurement and Clinical Engineering, Central Denmark Region, Aarhus, Denmark
| |
Collapse
|
5
|
Association between Phase Angle from Bioelectric Impedance and Muscular Strength and Power in Physically Active Adults. BIOLOGY 2022; 11:biology11091255. [PMID: 36138734 PMCID: PMC9495323 DOI: 10.3390/biology11091255] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/30/2022] [Revised: 08/20/2022] [Accepted: 08/21/2022] [Indexed: 11/25/2022]
Abstract
This study aimed to compare muscle strength and power indicators according to bioimpedance spectroscopy’s phase angle (PhA) values, in resistance-trained (RT) men, while exploring associations between PhA and performance. Forty-four men aged 18−45 years, engaged in RT, were allocated according to PhA tertiles. Lean soft tissue (LST) and fat mass (%FM) were assessed using dual-energy x-ray absorptiometry; dynamic muscle strength using 1 repetition maximum (1RM) of bench press (BP) and back squat (BS) and muscle power using Wingate test (WT) and countermovement jump (CMJ). For WT and CMJ, the 3rd tertile was significantly higher than the 1st tertile (p = 0.027 and p = 0.018, respectively). Regarding BP 1RM, the 3rd tertile was significantly higher than the 2nd tertile (p = 0.037). LST better explained the variability in the WT, BS and BP (p =< 0.001), while %FM better accounted for jump height in CMJ (p =< 0.001). PhA was a predictor of performance in both CMJ (p = 0.040) and BP (p = 0.012), independently of LST and %FM. Participants with higher PhA also displayed superior muscle strength of the upper limbs and greater muscle power of the lower limbs. PhA displayed significant moderate associations with performance in CMJ and BP, even after controlling for body composition. Still, LST was the most important predictor of muscle strength and power.
Collapse
|
6
|
Koşar ŞN, Güzel Y, Köse MG, Kin İşler A, Hazır T. Whole and segmental body composition changes during mid-follicular and mid-luteal phases of the menstrual cycle in recreationally active young women. Ann Hum Biol 2022; 49:124-132. [PMID: 35696275 DOI: 10.1080/03014460.2022.2088857] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Abstract
BACKGROUND Changes in oestradiol and progesterone hormones and associated fluid retention during the menstrual cycle phases might affect body composition (BC) in women. AIM The main objectives of this study were to determine the changes in whole and segmental BC by dual-energy x-ray absorptiometry (DXA) and bioelectrical impedance (BIA) during the mid-follicular (MFP) and mid-luteal (MLP) phases. SUBJECTS AND METHODS Thirty recreationally active young women participated in this study. BC was measured by DXA and BIA during MFP and MLP. A mixed linear model for repeated measures analysis was used to determine the differences between the two phases. RESULTS Body mass was higher during MLP than MFP, while total body water, total and segmental fat mass and fat percentages measured by both BIA and DXA were similar during the two phases. DXA-derived fat-free mass and soft lean mass in the android region were higher during MLP than MFP. Large variability in individual responses was evident. CONCLUSION On average, whole and segmental BC variables do not change significantly between MFP and MLP. However, given the large variability among the individual responses, it is suggested to perform repeated BC measurements during the same phase of the menstrual cycle.
Collapse
Affiliation(s)
- Şükran Nazan Koşar
- Division of Exercise Nutrition and Metabolism, Faculty of Sport Sciences, Hacettepe University, Ankara, Turkey
| | - Yasemin Güzel
- Division of Exercise Nutrition and Metabolism, Faculty of Sport Sciences, Hacettepe University, Ankara, Turkey
| | - Mehmet Gören Köse
- Division of Training and Movement Sciences, Faculty of Sport Sciences, Hacettepe University, Ankara, Turkey
| | - Ayşe Kin İşler
- Division of Training and Movement Sciences, Faculty of Sport Sciences, Hacettepe University, Ankara, Turkey
| | - Tahir Hazır
- Division of Training and Movement Sciences, Faculty of Sport Sciences, Hacettepe University, Ankara, Turkey
| |
Collapse
|
7
|
Wang LC, Raimann JG, Tao X, Preciado P, Thwin O, Rosales L, Thijssen S, Kotanko P, Zhu F. Estimation of fluid status using three multifrequency bioimpedance methods in hemodialysis patients. Hemodial Int 2022; 26:575-587. [PMID: 35719044 DOI: 10.1111/hdi.13034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Revised: 05/02/2022] [Accepted: 05/30/2022] [Indexed: 11/30/2022]
Abstract
INTRODUCTION Segmental eight-point bioimpedance has been increasingly used in practice. However, whether changes in bioimpedance analysis components before and after hemodialysis (HD) using this technique in a standing position is comparable to traditional whole-body wrist-to-ankle method is still unclear. We aimed to investigate the differences between two eight-point devices (InBody 770 and Seca mBCA 514) and one wrist-to-ankle (Hydra 4200) in HD patients and healthy subjects in a standing position. METHODS Thirteen HD patients were studied pre- and post-HD, and 12 healthy subjects once. Four measurements were performed in the following order: InBody; Seca; Hydra; and InBody again. Electrical equivalent models by each bioimpedance method and the fluid volume estimates by each device were also compared. FINDINGS Overall, total body water (TBW) was not different between the three devices, but InBody showed lower extracellular water (ECW) and higher intracellular water (ICW) compared to the other two devices. When intradialytic weight loss was used as a surrogate for changes in ECW (∆ECW) and changes in TBW (∆TBW), ∆ECW was underestimated by Hydra (-0.79 ± 0.89 L, p < 0.01), InBody (-1.44 ± 0.65 L, p < 0.0001), and Seca (-0.32 ± 1.34, n.s.). ∆TBW was underestimated by Hydra (-1.14 ± 2.81 L, n.s.) and InBody (-0.52 ± 0.85 L, p < 0.05) but overestimated by Seca (+0.93 ± 3.55 L, n.s.). DISCUSSION Although segmental eight-point bioimpedance techniques provided comparable TBW measurements not affected by standing over a period of 10-15 min, the ECW/TBW ratio appeared to be significantly lower in InBody compared with Seca and Hydra. Results from our study showed lack of agreement between different bioimpedance devices; direct comparison of ECW, ICW, and ECW/TBW between different devices should be avoided and clinicians should use the same device to track the fluid status in their HD population in a longitudinal direction.
Collapse
Affiliation(s)
| | | | - Xia Tao
- Renal Research Institute, New York, New York, USA
| | | | - Ohnmar Thwin
- Renal Research Institute, New York, New York, USA
| | | | | | - Peter Kotanko
- Renal Research Institute, New York, New York, USA.,Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Fansan Zhu
- Renal Research Institute, New York, New York, USA
| |
Collapse
|
8
|
Jiang F, Tang S, Eom JJ, Song KH, Kim H, Chung S, Kim CH. Accuracy of Estimated Bioimpedance Parameters with Octapolar Segmental Bioimpedance Analysis. SENSORS (BASEL, SWITZERLAND) 2022; 22:2681. [PMID: 35408295 PMCID: PMC9002650 DOI: 10.3390/s22072681] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/16/2022] [Revised: 03/27/2022] [Accepted: 03/30/2022] [Indexed: 06/14/2023]
Abstract
The validity of the impedance parameters of the five body segments estimated using octapolar segmental bioelectrical impedance analysis (OS-BIA) has not been confirmed. This study aimed to verify the accuracy of the resistance (R), reactance (Xc), and phase angle of each five-body segment. The accuracy of the OS-BIA at 50 kHz was measured based on the direct tetrapolar segmental BIA. The differences in the estimated impedance parameters of the five body segments were compared to those measured from the OS-BIA in elderly men (N = 73) and women (N = 63). The estimated 50 kHz-R (Ω) was significantly higher than the measured 50 kHz-R in the right and left arms, and lower than the measured 50 kHz-R of the trunk, right leg, and left leg (all, p < 0.05). The estimated 50 kHz-phase angles in all the five body segments were significantly lower than the measured ones (all, p < 0.05). The findings suggest that the estimated impedance parameters, R, Xc, and phase angle of the trunk, were remarkedly underestimated, limiting the assessment of the physiological state of the organs in the body. Therefore, further intensive research is needed in the field of estimated segmental BIA in the future.
Collapse
Affiliation(s)
- Fanglin Jiang
- National Traditional Sports Teaching and Research Section of Hunan Province, College of Physical Education, Hunan Normal University, Changsha 410012, China;
- Department of Sports Medicine, Soonchunhyang University, Asan 31538, Korea;
| | - Saizhao Tang
- Department of Sports Medicine, Soonchunhyang University, Asan 31538, Korea;
| | - Jin-Jong Eom
- Department of Sport, Leisure & Recreation, Soonchunhyang University, Asan 31538, Korea;
| | - Keon-Hyoung Song
- Department of Pharmaceutical Engineering, Soonchunhyang University, Asan 31538, Korea;
| | - Hyeoijin Kim
- Department of Physical Education, Korean National University of Education, Cheongju-si 38173, Korea;
| | - Sochung Chung
- Department of Pediatrics, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul 05030, Korea
| | - Chul-Hyun Kim
- Department of Sports Medicine, Soonchunhyang University, Asan 31538, Korea;
| |
Collapse
|
9
|
Tinsley GM, Stratton MT, Harty PS, Williams AD, White SJ, Rodriguez C, Dellinger JR, Johnson BA, Smith RW, Trexler ET. Influence of Acute Water Ingestion and Prolonged Standing on Raw Bioimpedance and Subsequent Body Fluid and Composition Estimates. JOURNAL OF ELECTRICAL BIOIMPEDANCE 2022; 13:10-20. [PMID: 35646197 PMCID: PMC9124033 DOI: 10.2478/joeb-2022-0003] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Indexed: 06/15/2023]
Abstract
This study evaluated the influence of acute water ingestion and maintaining an upright posture on raw bioimpedance and subsequent estimates of body fluids and composition. Twenty healthy adults participated in a randomized crossover study. In both conditions, an overnight food and fluid fast was followed by an initial multi-frequency bioimpedance assessment (InBody 770). Participants then ingested 11 mL/kg of water (water condition) or did not (control condition) during a 5-minute period. Thereafter, bioimpedance assessments were performed every 10 minutes for one hour with participants remaining upright throughout. Linear mixed effects models were used to examine the influence of condition and time on raw bioimpedance, body fluids, and body composition. Water consumption increased impedance of the arms but not trunk or legs. However, drift in leg impedance was observed, with decreasing values over time in both conditions. No effects of condition on body fluids were detected, but total body water and intracellular water decreased by ~0.5 kg over time in both conditions. Correspondingly, lean body mass did not differ between conditions but decreased over the measurement duration. The increase in body mass in the water condition was detected exclusively as fat mass, with final fat mass values ~1.3 kg higher than baseline and also higher than the control condition. Acute water ingestion and prolonged standing exert practically meaningful effects on relevant bioimpedance variables quantified by a modern, vertical multi-frequency analyzer. These findings have implications for pre-assessment standardization, methodological reporting, and interpretation of assessments.
Collapse
Affiliation(s)
- Grant M. Tinsley
- Energy Balance & Body Composition Laboratory; Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, TX, USA
| | - Matthew T. Stratton
- Energy Balance & Body Composition Laboratory; Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, TX, USA
| | - Patrick S. Harty
- Energy Balance & Body Composition Laboratory; Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, TX, USA
| | - Abegale D. Williams
- Energy Balance & Body Composition Laboratory; Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, TX, USA
| | - Sarah J. White
- Energy Balance & Body Composition Laboratory; Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, TX, USA
| | - Christian Rodriguez
- Energy Balance & Body Composition Laboratory; Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, TX, USA
| | - Jacob R. Dellinger
- Energy Balance & Body Composition Laboratory; Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, TX, USA
| | - Baylor A. Johnson
- Energy Balance & Body Composition Laboratory; Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, TX, USA
| | - Robert W. Smith
- Energy Balance & Body Composition Laboratory; Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, TX, USA
- Department of Nutrition and Health Sciences, University of Nebraska-Lincoln, Lincoln, Nebraska, USA
| | | |
Collapse
|
10
|
Tinsley GM, Moore ML, Rafi Z, Griffiths N, Harty PS, Stratton MT, Benavides ML, Dellinger JR, Adamson BT. Explaining Discrepancies Between Total and Segmental DXA and BIA Body Composition Estimates Using Bayesian Regression. J Clin Densitom 2021; 24:294-307. [PMID: 32571645 DOI: 10.1016/j.jocd.2020.05.003] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/14/2020] [Revised: 04/16/2020] [Accepted: 05/05/2020] [Indexed: 12/23/2022]
Abstract
INTRODUCTION/BACKGROUND Few investigations have sought to explain discrepancies between dual-energy X-ray absorptiometry (DXA) and bioelectrical impedance analysis (BIA) body composition estimates. The purpose of this analysis was to explore physiological and anthropometric predictors of discrepancies between DXA and BIA total and segmental body composition estimates. METHODOLOGY Assessments via DXA (GE Lunar Prodigy) and single-frequency BIA (RJL Systems Quantum V) were performed in 179 adults (103 F, 76 M, age: 33.6 ± 15.3 yr; BMI: 24.9 ± 4.3 kg/m2). Potential predictor variables for differences between DXA and BIA total and segmental fat mass (FM) and lean soft tissue (LST) estimates were obtained from demographics and laboratory techniques, including DXA, BIA, bioimpedance spectroscopy, air displacement plethysmography, and 3-dimensional optical scanning. To determine meaningful predictors, Bayesian robust regression models were fit using a t-distribution and regularized hierarchical shrinkage "horseshoe" prior. Standardized model coefficients (β) were generated, and leave-one-out cross validation was used to assess model predictive performance. RESULTS LST hydration (i.e., total body water:LST) was a predictor of discrepancies in all FM and LST variables (|β|: 0.20-0.82). Additionally, extracellular fluid percentage was a predictor for nearly all outcomes (|β|: 0.19-0.40). Height influenced the agreement between whole-body estimates (|β|: 0.74-0.77), while the mass, length, and composition of body segments were predictors for segmental LST estimates (|β|: 0.23-3.04). Predictors of segmental FM errors were less consistent. Select sex-, race-, or age-based differences between methods were observed. The accuracy of whole-body models was superior to segmental models (leave-one-out cross-validation-adjusted R2 of 0.83-0.85 for FMTOTAL and LSTTOTAL vs. 0.20-0.76 for segmental estimates). For segmental models, predictive performance decreased in the order of: appendicular lean soft tissue, LSTLEGS, LSTTRUNK and FMLEGS, FMARMS, FMTRUNK, and LSTARMS. CONCLUSIONS These findings indicate the importance of LST hydration, extracellular fluid content, and height for explaining discrepancies between DXA and BIA body composition estimates. These general findings and quantitative interpretation based on the presented data allow for a better understanding of sources of error between 2 popular segmental body composition techniques and facilitate interpretation of estimates from these technologies.
Collapse
Affiliation(s)
- Grant M Tinsley
- Energy Balance & Body Composition Laboratory, Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, TX, USA.
| | - M Lane Moore
- Energy Balance & Body Composition Laboratory, Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, TX, USA; Mayo Clinic Alix School of Medicine, Scottsdale, AZ, USA
| | - Zad Rafi
- NYU Langone Medical Center, New York, NY, USA
| | - Nelson Griffiths
- Energy Balance & Body Composition Laboratory, Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, TX, USA
| | - Patrick S Harty
- Energy Balance & Body Composition Laboratory, Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, TX, USA
| | - Matthew T Stratton
- Energy Balance & Body Composition Laboratory, Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, TX, USA
| | - Marqui L Benavides
- Energy Balance & Body Composition Laboratory, Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, TX, USA
| | - Jacob R Dellinger
- Energy Balance & Body Composition Laboratory, Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, TX, USA
| | - Brian T Adamson
- Energy Balance & Body Composition Laboratory, Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, TX, USA; School of Physical Therapy, Texas Woman's University, Denton, TX, USA
| |
Collapse
|
11
|
Stratton MT, Smith RW, Harty PS, Rodriguez C, Johnson BA, Dellinger JR, Williams AD, White SJ, Benavides ML, Tinsley GM. Longitudinal agreement of four bioimpedance analyzers for detecting changes in raw bioimpedance during purposeful weight gain with resistance training. Eur J Clin Nutr 2021; 75:1060-1068. [PMID: 33727706 DOI: 10.1038/s41430-020-00811-3] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2020] [Revised: 10/21/2020] [Accepted: 11/09/2020] [Indexed: 01/26/2023]
Abstract
BACKGROUND Due to inherent errors involved in the transformation of raw bioelectrical variables to body fluids or composition estimates, the sole use of resistance (R), reactance (Xc), and phase angle (φ) has been advocated when quantifying longitudinal changes. The aim of this investigation was to assess the ability of four bioimpedance analyzers to detect raw bioimpedance changes induced by purposeful weight gain with resistance training. METHODS Twenty-one resistance trained males completed a 6-week lifestyle intervention with the aim of purposeful weight gain. Bioimpedance analysis was performed before and after the intervention using four different analyzers (MFBIAInBody: InBody 770; MFBIASECA: Seca mBCA 515/514; BIS: ImpediMed SFB7; SFBIA: RJL Quantum V) for the quantification of R, Xc, and φ at the 50-kHz frequency. Repeated measures ANOVA and follow up tests were performed. RESULTS Analysis revealed main effects of time and method for R, Xc, and φ (p ≤ 0.02), without significant time x method interactions (p ≥ 0.07). Follow up for time main effects indicated that, on average, R decreased by 4.5-5.8%, Xc decreased by 2.3-4.0%, and φ increased by 1.8-2.6% across time for all analyzers combined. However, varying levels of disagreement in absolute values were observed for each bioelectrical variable. CONCLUSIONS The differences in absolute bioelectrical values suggests that analyzers should not be used interchangeably, which holds particular importance when reference values are utilized. Despite absolute differences, analyzers with varying characteristics demonstrated similar abilities to detect changes in R, Xc, and φ over time.
Collapse
Affiliation(s)
- Matthew T Stratton
- Energy Balance & Body Composition Laboratory; Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, TX, USA
| | - Robert W Smith
- Energy Balance & Body Composition Laboratory; Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, TX, USA
| | - Patrick S Harty
- Energy Balance & Body Composition Laboratory; Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, TX, USA
| | - Christian Rodriguez
- Energy Balance & Body Composition Laboratory; Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, TX, USA
| | - Baylor A Johnson
- Energy Balance & Body Composition Laboratory; Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, TX, USA
| | - Jacob R Dellinger
- Energy Balance & Body Composition Laboratory; Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, TX, USA
| | - Abegale D Williams
- Energy Balance & Body Composition Laboratory; Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, TX, USA
| | - Sarah J White
- Energy Balance & Body Composition Laboratory; Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, TX, USA
| | - Marqui L Benavides
- Energy Balance & Body Composition Laboratory; Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, TX, USA
| | - Grant M Tinsley
- Energy Balance & Body Composition Laboratory; Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, TX, USA.
| |
Collapse
|
12
|
Marra M, Di Vincenzo O, Sammarco R, Morlino D, Scalfi L. Bioimpedance phase angle in elite male athletes: a segmental approach. Physiol Meas 2021; 41:125007. [PMID: 33202393 DOI: 10.1088/1361-6579/abcb5c] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
OBJECTIVE Phase angle (PA), a bioelectrical impedance analysis (BIA) parameter, has proven to be a proxy of body cell mass in athletes, but very few data are available on its segmental evaluation (upper and lower limbs). Therefore, we aimed to assess whether whole-body and segmental PA varied among elite male athletes of different sports and compared these to control groups. Additionally, we investigated its relationship with anthropometric and body composition parameters. APPROACH Elite athletes practicing cycling, water polo and ballet dance aged 18-40 years underwent anthropometric and BIA measurements. PA (whole-body and upper and lower limbs) was considered as raw BIA variable. Data were also compared with healthy subjects with similar characteristics who served as control groups. MAIN RESULTS Participants included three groups of male athletes: 18 cyclists (age 28.6 ± 3.4 years; weight 70.6 ± 5.4 kg; BMI 21.5 ± 1.4 kg m2), 20 water polo players (age 23.9 ± 4 years; weight 89.0 ± 5.2 kg; BMI 25.9 ± 1.9 kg m2) and 18 ballet dancers (age 19.2 ± 1.3 years; weight 63.3 ± 5.8 kg; BMI 20.8 ± 1.0 kg m2) and three groups of healthy control subjects each of which similar for general characteristics (one to one) to the previous ones. Both whole-body and limb PAs were significantly higher in athletes compared to their respective controls, whereas no differences were found among sport groups. PA was positively correlated with BMI and fat-free mass (FFM) more in athletes than in controls and FFM was the main determinant. SIGNIFICANCE PA may represent a useful proxy parameter of soft tissue mass quality, directly related to physical activity level. Furthermore, the direct evaluation of segmental PA among athletes practicing different sports may be useful for assessing and monitoring the differences among athletes and changes due to training.
Collapse
Affiliation(s)
- Maurizio Marra
- Department of Clinical Medicine and Surgery, Federico II University of Naples, Via S. Pansini 5, Naples 80138, Italy
| | | | | | | | | |
Collapse
|