1
|
Al Ahmari NM, Alshehri AH, Gadah TS, Alqahtani JA, Almushafi MA, Al Moaleem MM, Al Hatlan EN, Alqhatani AS, Alabydi SM. Comparison of color changes, fracture strengths, and failure modes of conventional endocrowns and endocrowns with different design modifications. Technol Health Care 2024:THC231175. [PMID: 38427513 DOI: 10.3233/thc-231175] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/03/2024]
Abstract
BACKGROUND Endocrowns (ECs) are alternatives for rebuilding severely damaged teeth and show superior efficacy in molars over premolars. OBJECTIVE The objective of this in vitro study is to evaluate the effects of different preparation designs with short pulp chambers on the mean color change (ΔE), fracture resistance, and failure types of mandibular molar ECs. METHOD A total of 40 extracted mandibular molars were treated endodontically and divided into four groups. Samples in groups 1, 2, 3, and 4 had occlusal preparation depths of 5 mm, 3 mm, 3 mm with ferrule, and 3 mm with boxes, respectively. The samples were immersed in coffee and their ΔE values were measured by using the Commission Internationale de l'Eclairage color system. They were also subjected to a fracture test. Next, all specimens were examined visually under a stereomicroscope to evaluate their failure modes and identify their fracture origins. Data were entered and analyzed by using Statistical Package for Social Sciences. RESULTS Among all groups, group 4 (3 mm + boxes) presented the highest ΔE (4.15) after immersion in coffee. Moreover, ANOVA revealed that the ΔE of group 4 (occlusal preparation depth of 3 mm with boxes) was significantly different (p< 0.05) from that of group 2 (3 mm + ferrule, 3.07). The EC with a 3 mm chamfer and ferrule showed the highest maximum load of 2847.68 ± 693.27 N, whereas that with a 5 mm chamfer finish line had a marginally reduced load at fracture of 2831.52 ± 881.83 N. The EC with a 3 mm chamber and boxes had a slightly increased maximum load of 2700.75 ± 436.40 N, whereas that with the 3 mm chamber had the lowest maximum load at fracture of 2385.97 ± 465.61 N. One-way ANOVA showed that different EC preparation designs had no effect on maximum fracture load (F [3,16] = 0.550, p= 0.6). CONCLUSION The recorded ΔE values of ECs in all groups were equal or marginally higher than the acceptable values. The EC with a 3 mm chamfer and ferrule displayed the highest mean maximum load. The EC with a 5 mm chamfer finish line had a marginally lower maximum load at fracture than other ECs. Failures, such as ceramic fracture, split fracture, and ceramic and tooth splitting above the cemento-enamel junction (CEJ) or vertically were predominant in samples with occlusal preparation depths of 3 mm with ferrule and 5 mm.
Collapse
Affiliation(s)
- Nasser M Al Ahmari
- College of Dentistry, King Khalid University, Abha, Saudi Arabia
- College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Abdulkarim H Alshehri
- Department of Prosthetic Dental Science, College of Dentistry, Jazan University, Jazan, Saudi Arabia
- College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Thrya S Gadah
- College of Dentistry, King Khalid University, Abha, Saudi Arabia
- College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Jaber A Alqahtani
- Aseer Specialized Dental Center, Ministry of Health, Abha, Saudi Arabia
| | | | - Mohammed M Al Moaleem
- Department of Prosthetic Dental Science, College of Dentistry, Jazan University, Jazan, Saudi Arabia
- College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | | | | | | |
Collapse
|
2
|
Saleh KA, Hammad IA, Aly YM. Effect of mouth rinses on the stainability of monolithic lithium disilicate glass-ceramics with different surface treatments: An in vitro study. J Prosthet Dent 2023; 130:935.e1-935.e6. [PMID: 37802732 DOI: 10.1016/j.prosdent.2023.09.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Revised: 09/11/2023] [Accepted: 09/12/2023] [Indexed: 10/08/2023]
Abstract
STATEMENT OF PROBLEM Mouth rinses have been reported to cause tooth surface discoloration. However, information regarding their effect on the stainability of monolithic glass-ceramics with different surface treatments is lacking. PURPOSE The purpose of this in vitro study was to assess the effect of mouth rinses on the color change of milled and pressed monolithic lithium disilicate glass-ceramics with different surface treatments. MATERIAL AND METHODS Fifty-six Ø12×1.5-mm disk specimens were fabricated using 2 different processing techniques: milling and pressing. Each group was subdivided into 2 subgroups according to surface treatments: glazed and polished. Specimens were then immersed in 2 different types of mouth rinse (n=7): chlorhexidine (CHX) and Listerine (LST). Color parameters were assessed using a digital spectrophotometer. Color difference (ΔE00) was calculated and compared with perceptibility (ΔE00=0.8) and acceptability (ΔE00=1.8) thresholds. The data were analyzed using ANOVA and Tukey post hoc tests (α=.05). RESULTS The color difference (ΔE00) was significantly affected by the type of processing technique, surface treatment, and mouth rinse (P<.001) and their interaction (P=.008). All ΔE00 values were below the selected clinical acceptability threshold (ΔE00=1.8). Milled groups (ΔE00=1.13) showed greater discoloration than pressed groups (ΔE00=0.86). Glazed specimens (ΔE00=0.70) were more resistant to discoloration than polished specimens (ΔE00=1.28) and immersion in CHX (ΔE00=1.09) led to more discoloration than immersion in LST (ΔE00=0.89). CONCLUSIONS The color of milled and pressed monolithic lithium disilicate glass-ceramics with different surface treatments was affected by using CHX and LST mouth rinses. Glazed lithium disilicate glass-ceramics showed less staining compared with those that were polished. Specimens immersed in CHX showed more discoloration than those immersed in LST.
Collapse
Affiliation(s)
- Karim A Saleh
- Postgraduate student, Department of Conservative Dentistry, Alexandria University, Alexandria, Egypt.
| | - Ihab A Hammad
- Professor and Former Dean, Department of Conservative Dentistry, Alexandria University, Alexandria, Egypt
| | - Yasser M Aly
- Lecturer, Department of Conservative Dentistry, Alexandria University, Alexandria, Egypt
| |
Collapse
|
3
|
Nascimento VA, Bento VAA, Cruz KH, Silva LS, Pesqueira AA, Pellizzer EP. Color stability and surface roughness of resin-ceramics with different surface treatments: A systematic review and meta-analysis of in vitro studies. J Prosthet Dent 2023:S0022-3913(23)00567-X. [PMID: 37805289 DOI: 10.1016/j.prosdent.2023.08.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 08/22/2023] [Accepted: 08/23/2023] [Indexed: 10/09/2023]
Abstract
STATEMENT OF PROBLEM Surface treatments for resin-ceramics have been developed to obtain a smooth surface and improve color stability. However, a consensus on the best treatment for these materials is lacking. PURPOSE The purpose of this systematic review and meta-analysis was to evaluate the color stability and roughness of glass-ceramics versus resin-ceramics with different surface treatments. MATERIAL AND METHODS The preferred reporting items for systematic reviews and meta-analyses (PRISMA) guidelines were followed, and the study was registered in the open science framework (OSF) for in vitro studies. The population, intervention, control, and outcome (PICO) question was "Is there a difference in color stability and roughness between resin-ceramic vs vitreous ceramics in different surface treatment protocols?" A literature search was performed in PubMed/MEDLINE, Embase, Web of Science, Scopus, Cochrane Library, and ProQuest databases up to January 2023. The Joanna Briggs Institute's critical assessment guidelines for quasi-experimental studies were used for quality assessment. The meta-analysis was based on the inverse variance (IV) method (α=.05). RESULTS A total of 18 laboratory studies were published between 2015 and 2022, with a total of 2160 specimens, all of which were analyzed qualitatively. The meta-analysis indicated significantly less optical alteration for lithium disilicate ceramics (P<.01; MD: 2.69; 95% CI: 2.00-3.39; I²=89%, P<.01), even when compared with resin-ceramics with polish or sealants (P<.01; MD: 2.45; 95% CI: 1.59-3.30; I²=87%, P<.01) and (P<.01; MD: 3.24; 95% CI: 2.02-4.47; I²=89%, P<.01), while there was no significant difference in surface roughness (P=.08; MD: -0.71; CI 95%: -1.52 to 0.09; I²=87%, P<.01) (P=.33; MD: -0.31; CI 95%: -0.94 to 0.32; I²=87%, P<.01), respectively. CONCLUSIONS Resin-ceramics that have been polished or treated with sealants have lower color stability than glazed glass-ceramics; however, they are similar in terms of surface roughness.
Collapse
Affiliation(s)
- Victor Alves Nascimento
- Postgraduate student, Department of Dental Materials and Prosthodontics, Araçatuba Dental School, São Paulo State University (UNESP), Araçatuba, São Paulo, Brazil.
| | - Victor Augusto Alves Bento
- Postgraduate student, Department of Dental Materials and Prosthodontics, Araçatuba Dental School, São Paulo State University (UNESP), Araçatuba, São Paulo, Brazil
| | - Kevin Henrique Cruz
- Postgraduate student, Department of Dental Materials and Prosthodontics, Araçatuba Dental School, São Paulo State University (UNESP), Araçatuba, São Paulo, Brazil
| | - Lorena Scaion Silva
- Postgraduate student, Department of Dental Materials and Prosthodontics, Araçatuba Dental School, São Paulo State University (UNESP), Araçatuba, São Paulo, Brazil
| | - Aldiéris Alves Pesqueira
- Adjunct Professor, Department of Dental Materials and Prosthodontics, Araçatuba Dental School, São Paulo State University (UNESP), Araçatuba, São Paulo, Brazil
| | - Eduardo Piza Pellizzer
- Full Professor, Department of Dental Materials and Prosthodontics, Araçatuba Dental School, São Paulo State University (UNESP), Araçatuba, São Paulo, Brazil
| |
Collapse
|
4
|
Yamalı Y, Bankoğlu Güngör M, Karakoca Nemli S, Turhan Bal B. The effects of cement thickness and cement shade on the final color of lithium disilicate crowns. J Adv Prosthodont 2023; 15:93-100. [PMID: 37153007 PMCID: PMC10154146 DOI: 10.4047/jap.2023.15.2.93] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2023] [Revised: 04/12/2023] [Accepted: 04/21/2023] [Indexed: 05/09/2023] Open
Abstract
PURPOSE The aim of this study is to evaluate the effect of resin cement color, cement thickness, and thermocycling on the final color of monolithic lithium disilicate crowns. MATERIALS AND METHODS A total of ninety prepared central incisors of typodont teeth were restored with lithium disilicate crowns which have different cement thicknesses (40 µm, 80 µm, and 120 µm) and cement shades (clear, yellow, and white). Color parameters of restorations were measured with a spectrophotometer in three different steps 1) before cementing 2) after cementing and 3) after thermocycling with 10000 cycles. Color differences (ΔE00) were calculated with the CIEDE2000 formula and evaluated according to perceptibility (0.8) and acceptability (1.8) thresholds. The ΔE00 data were analyzed by using two-way ANOVA before and after thermocycling (α = .05). RESULTS There was no interaction between the cement shade and the cement thickness factors. After cementation, the mean ΔE00 was under the perceptibility threshold in the group of 40 µm cement thickness and clear cement while it was between the perceptibility and acceptability thresholds (0.8 < ΔE00 < 1.8) for all other groups. After thermocycling, the ΔE00 values were between the perceptibility and acceptability thresholds for all experimental groups. Although there were no significant differences among the groups, thermocycling increased the color difference values. CONCLUSION The cementation of restorations with clear, yellow, and white resin cements resulted in color differences with uncemented restorations except for the group cemented with clear cement in 40 µm cement thickness. All study groups revealed perceptible color change after thermocycling.
Collapse
Affiliation(s)
| | - Merve Bankoğlu Güngör
- Department of Prosthodontics, Faculty of Dentistry, Gazi University, Ankara, Türkiye
| | - Seçil Karakoca Nemli
- Department of Prosthodontics, Faculty of Dentistry, Gazi University, Ankara, Türkiye
| | - Bilge Turhan Bal
- Department of Prosthodontics, Faculty of Dentistry, Gazi University, Ankara, Türkiye
| |
Collapse
|
5
|
Al Wadei MH. Comparison of the Degree of Staining of Computer-Aided Design-Computer-Aided Manufacture (CAD-CAM) Ceramic Veneers by Green Tea, Coffee, and Coca-Cola Using a Digital Spectrophotometer. Med Sci Monit 2023; 29:e939341. [PMID: 36747464 PMCID: PMC9920997 DOI: 10.12659/msm.939341] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023] Open
Abstract
BACKGROUND The majority of dental professionals currently recognize lithium disilicate E-max ceramic veneers as a the most widely used, conservative, and effective cosmetic materials in dentistry. This study aimed to compare the degree of surface changes - roughness (Ra), depth (Rz), and mean color changes (ΔE₀₀) - of computer-aided design-computer-aided manufactured (CAD/CAM) ceramic veneers materials of varying thicknesses caused by staining by green tea, coffee, and Coca-Cola using digital spectrophotometer. MATERIAL AND METHODS This study was conducted at King Khalid University, College of Dentistry. Lithium disilicate glass ceramic (LDGC) material was used to create 60 rectangular slices using the CAD/CAM system. The material thickness and the type of beverage were measured. The specimens were immersed in beverages according to the manufacturer's instructions. Specimen description and tomography were completed with a 3D noncontact surface metrology using interferometry. The "VITA Easy-Shade" spectrophotometer was used to measure ΔE₀₀. It was recorded after 2 weeks for different material thicknesses after immersing samples in green tea, coffee, and Coca-Cola staining materials.f RESULTS Significant changes in ceramic thickness were found in Ra and Rz of 0.07 and 1.00 mm after 14 days of staining. Coca-Cola showed a significant difference in Ra and Rz with 1.00 mm thickness measurement compared to the 0.07 mm group with ≤ of 0.05, which was considered statistically significant. Highest ΔE₀₀ were recorded among samples stained by Coca-Cola, followed by coffee, for both thicknesses. CONCLUSIONS Those findings support previous studies using spectrophotometric analysis of staining of CAD-CAM ceramic veneers that Coca-Cola followed by coffee resulted in the greatest color ΔE₀₀ change.
Collapse
Affiliation(s)
- Mohammed H.D. Al Wadei
- Department of Restorative Dental Science, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| |
Collapse
|
6
|
Singh RG, Lyons KM, Waddell JN, Li KC. Effect of thermocycling on the mechanical properties, inorganic particle release and low temperature degradation of glazed high translucent monolithic 3Y-TZP dental restorations. J Mech Behav Biomed Mater 2022; 136:105495. [PMID: 36208582 DOI: 10.1016/j.jmbbm.2022.105495] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Revised: 09/27/2022] [Accepted: 09/27/2022] [Indexed: 11/24/2022]
Abstract
The influence of thermocycling on the surface deterioration of glazed monolithic high translucent 3Y-TZP dental restorations is still unclear. The purpose of this study therefore was to evaluate low temperature degradation (LTD), elemental release and surface degradation pattern after five years of simulated clinical time. A total of 123 specimens were prepared from second-generation high translucent 3Y-TZP as per ISO 6872:2015 standards (3 mm × 4 mm × 30 mm). They were classified as per glazing and thermocycling protocol; group CPT, DGT and IGT. Glaze materials were applied on one surface of the specimen and subjected to a thermocycling in artificial saliva, four-point bending test, inductively coupled plasma mass spectrometry (ICP-MS), scanning electron microscopy (SEM), energy dispersive x-ray spectroscopy (EDX) and x-ray diffraction (XRD). Flexural strength, characteristic strength and Weibull modulus values were derived from four-point bending test. Descriptive fractographic analysis of surfaces was conducted to observe the surface degradation characteristics and point of failure. Control/no glaze with thermocycling (CPT = 621.5, 1σ = 117.0 MPa) presented higher flexural strength values compared to glaze I with thermocycling (442.4, 1σ = 45.4 MPa) and glaze II with thermocycling (534.3, 1σ = 46.3 MPa). Characteristic strength from Weibull analysis also observed higher values (669.2 MPa) for the control specimens. XRD analysis showed that monoclinic volume fraction (Vm = 11.0, 1σ = 0.7%) was highest in control specimens. Fractographic analysis suggested that there was no correlation between the point of failure initiation and mean flexural strength values. Glazing protected the high translucent 3Y-TZP surface against LTD during thermocycling but negatively impacted on the flexural strength.
Collapse
Affiliation(s)
- Raj Gaurav Singh
- Department of Oral Rehabilitation, Faculty of Dentistry, University of Otago, New Zealand.
| | - Karl Michael Lyons
- Department of Oral Rehabilitation, Faculty of Dentistry, University of Otago, New Zealand.
| | - John Neil Waddell
- Department of Oral Rehabilitation, Faculty of Dentistry, University of Otago, New Zealand.
| | - Kai Chun Li
- Department of Oral Rehabilitation, Faculty of Dentistry, University of Otago, New Zealand.
| |
Collapse
|
7
|
Al Ahmari NM, Alahmari MA, Al Moaleem MM, Alshahrani RSA, Alqahtani FF, Mohammed WS, Al-Makramani BMA, Mehta V, Meto A, Meto A. Physical, Optical, and Mechanical Properties of Ceramic Materials after Coffee Immersion and Evaluation of Cleaning Impact with Different Oral Hygiene Tools. Int J Environ Res Public Health 2022; 19:15047. [PMID: 36429767 PMCID: PMC9690395 DOI: 10.3390/ijerph192215047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Revised: 11/13/2022] [Accepted: 11/13/2022] [Indexed: 06/16/2023]
Abstract
This study aimed to evaluate the effect of three oral hygiene tools, a regular toothbrush, an electronic toothbrush, and mouthwash, on the color stability of three different computer-aided design (CAD) and computer-aided manufactured (CAM) ceramic blocks. Feldspathic ceramic (Vita Triluxe Forte), hybrid resin ceramic (Vita Enamic), and lithium disilicate glass-ceramic (IPS e.max CAD) were used in this study. A CAD/CAM system and 81 (27 of each material) samples of ceramic blocks were used. All samples were immersed in black coffee for 15 days, and the coffee was changed twice per day. Using a spectrophotometer probe, samples on a grey background were scanned, and physical properties like surface hardness and depth were measured using interferometry and a 3D non-contact surface metrology. After 30 days of application of oral hygiene tools, instruments were used to measure various physical, mechanical, and optical properties. Vita Triluxe had the highest average color variation values (ΔE00) after 15 and 30 days of immersion in coffee in both regular and electronic toothbrushes. Moreover, IPS e.max CAD had the least ΔE00 values with no significant differences among the groups. The surface roughness (Ra) of the Vita Enamic ceramic increased when using a regular toothbrush, and the surface height (Rz) for the Vita Enamic ceramic increased when an electronic toothbrush was used. IPS e.max CAD had the greatest modules of elasticity forces, and Vita Triluxe Forte had the lowest when used with a regular toothbrush. The ΔE00 values of the tested materials were minimally increased or decreased after 30 days of cleaning, and all were clinically acceptable. Ra and Rz were the highest for Vita Enamic in comparison to the other groups. The highest percentage in IPS e.max CAD was associated with a type 1 fracture, whereas type 3 was predominantly observed with Vita Enamic, and type 2 in the Vita Triluxe group without significant differences.
Collapse
Affiliation(s)
- Nasser M. Al Ahmari
- Prosthetic Department, College of Dentistry, King Khalid University, Abha 62529, Saudi Arabia
| | - Maram A. Alahmari
- Saudi Board Prosthodontic Resident, College of Dentistry, King Khalid University, Abha 62529, Saudi Arabia
| | - Mohammed M. Al Moaleem
- Department of Prosthetic Dental Science, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia
- Faculty of Dentistry, University of Ibn al-Nafis for Medical Sciences, Sana’a 4337, Yemen
| | | | - Fatimah F. Alqahtani
- Dental Interns, College of Dentistry, King Khalid University, Abha 62529, Saudi Arabia
| | - Waad Saeed Mohammed
- Dental Interns, College of Dentistry, King Khalid University, Abha 62529, Saudi Arabia
| | - Bandar M. A. Al-Makramani
- Department of Prosthetic Dental Science, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia
| | - Vini Mehta
- Department of Public Health Dentistry, Dr. D.Y. Patil Dental College and Hospital, Dr. D.Y. Patil Vidyapeeth, Pune 411018, India
| | - Aida Meto
- Department of Dentistry, Faculty of Dental Sciences, University of Aldent, 1007 Tirana, Albania
- Clinical Microbiology, School of Dentistry, University of Modena and Reggio Emilia, 41125 Modena, Italy
| | - Agron Meto
- Department of Dentistry, Faculty of Dental Sciences, University of Aldent, 1007 Tirana, Albania
| |
Collapse
|
8
|
Alzahrani AH, Aldosari LIN, Alshadidi AAF, Al Moaleem MM, Dhamiri RA, Aldossary MB, Hazazi YY, Awaji FA, Ageeli AM. Influence of Surface Type with Coffee Immersion on Surface Topography and Optical and Mechanical Properties of Selected Ceramic Materials. Med Sci Monit 2022; 28:e938354. [PMID: 36320129 PMCID: PMC9639350 DOI: 10.12659/msm.938354] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND The aim of this study was to assess and compare the effect of surface type (glazed or polished) with coffee immersion and aging on surface topography (Ra), optical properties (TP, OP), and mechanical properties (fracture forces and modes) of zirconia-reinforced lithium silicate (Vita Suprinity), hybrid polymer-infiltrated-feldspathic ceramic network material (Vita Enamic), and leucite-containing feldspathic glass (Vitablocs® Mark II) made by computer-aided design and computer-aided manufactured (CAD/CAM) ceramic materials. MATERIAL AND METHODS Fifty-four specimens were assembled out of the above 3 CAD/CAMs ceramic materials. Each group was divided into glazed or polished surfaces, having 9 specimens of every type and stained in coffee for 15 days. Ra and color of specimens in the form of TP and OP were recorded before and after immersion in staining material. Fracture forces and modes were analyzed after the 90-day aging. Data were analyzed using ANOVA, then post hoc analysis and Bonferroni tests. RESULTS Our study found significant differences in Ra, TP, and Op before and after coffee immersion between glazed and polished specimens, with higher values in the polished surfaces among the 3 ceramic materials. The highest values of fracture resistance were noted in Vita Suprinity, and Vita Enamic had the lowest values, without significant differences among groups. CONCLUSIONS Most of the TP and OP values were in acceptable clinical range, and Vita Suprinity had superior TP than the other groups. Reparable fracture types were observed in Vita Suprinity, whereas semi-reparable and non-reparable were predominant in other groups.
Collapse
Affiliation(s)
| | | | | | - Mohammed M. Al Moaleem
- Department of Prosthetic Dental Science, College of Dentistry, Jazan University, Jazan, Saudi Arabia,Faculty of Dentistry, University of Ibn al-Nafis for Medical Sciences, Sana’a, Yemen
| | | | | | | | | | | |
Collapse
|
9
|
Schelkopf S, Dini C, Beline T, Wee AG, Barão VAR, Sukotjo C, Yuan JCC. The Effect of Smoking and Brushing on the Color Stability and Stainability of Different CAD/CAM Restorative Materials. Materials (Basel) 2022; 15:ma15196901. [PMID: 36234241 PMCID: PMC9571481 DOI: 10.3390/ma15196901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Revised: 09/22/2022] [Accepted: 10/02/2022] [Indexed: 05/14/2023]
Abstract
This study aimed to investigate and compare the color stability and stainability of computer-aided design/computer-aided manufacturing (CAD/CAM) restorative materials in their glazed (G) and polished (P) state when exposed to cigarette smoke, as well as after brushing. Three CAD/CAM restorative materials were investigated: lithium disilicate CAD (LD), zirconia (Zr), and Telio PMMA CAD (PMMA), according to their surface finishing and assignment to cigarette smoking exposure or soaking in the saliva (control) group. The color change (∆E) was calculated before and after the intervention performed for all specimens, using the L*a*b values to quantitatively assess the shade differences. Statistical analysis was performed using one-way repeated measures ANOVA and Bonferroni multiple comparison analysis (α = 0.05). The surface finishing did not influence the materials’ stainability. Color change was noted after smoking, LD and Zr-G and Zr-P had a comparable color change (p > 0.05), while PMMA presented lower ∆E values (p < 0.05). After brushing, all specimens had a significant color change that was high for LD-G and LD-P, and Zr-G, compared with Zr-P and PMMA (p < 0.05). In conclusion, the exposure to cigarette smoke showed that LD, Zr, and PMMA are all susceptible to staining, but brushing decreases surface staining.
Collapse
Affiliation(s)
- Stuart Schelkopf
- Private Practice, University Associates in Dentistry, 222 N Lasalle St., Chicago, IL 60601, USA
| | - Caroline Dini
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Av. Limeira, 901, Piracicaba 13414-903, São Paulo, Brazil
| | - Thamara Beline
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Av. Limeira, 901, Piracicaba 13414-903, São Paulo, Brazil
| | - Alvin G. Wee
- Department of Restorative Sciences, School of Dentistry, University of Minnesota, 9-470 Moos Tower, 515 Delaware St. SE, Minneapolis, MN 55455, USA
| | - Valentim A. R. Barão
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Av. Limeira, 901, Piracicaba 13414-903, São Paulo, Brazil
| | - Cortino Sukotjo
- Department of Restorative Dentistry, College of Dentistry, University of Illinois Chicago, 801 S Paulina, Chicago, IL 60612, USA
- Correspondence: (C.S.); (J.C.-C.Y.)
| | - Judy Chia-Chun Yuan
- Department of Restorative Dentistry, College of Dentistry, University of Illinois Chicago, 801 S Paulina, Chicago, IL 60612, USA
- Correspondence: (C.S.); (J.C.-C.Y.)
| |
Collapse
|
10
|
Alshehri A, Alrefeai MH, Alzamil F, Alotaibi N, Alkinani Y. Effect of Over-The-Counter Tooth-Whitening Products on Enamel Surface Roughness and Microhardness. Applied Sciences 2022; 12:6930. [DOI: 10.3390/app12146930] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background: To evaluate the efficacy of new over-the-counter tooth-whitening products on enamel surface roughness and microhardness. Methods: A total of 120 enamel specimens were prepared and randomly allocated into six groups. Group A was treated with 10% carbamide peroxide; Group B was immersed in distilled water; Group C was treated with hydrated silica, sodium hexametaphosphate toothpaste; Group D was treated with sodium bicarbonate; Group E was treated with 0.25% citric acid; and Group F was treated with hydrated silica, charcoal powder. Results: A, B, and D demonstrated decreased Ra, whereas Groups C, E, and F showed an increased Ra after whitening. The changes in Ra from T0 to T1 in each group was statistically significant (p < 0.001) except for Group B (p = 0.85). The groups showed decreased KHN after whitening, except for specimens in Group B (distilled water). The KHN from T0 to T1 decreased significantly for groups A, C, E, and F (p = 0.001). Significant difference was observed at T1 (p < 0.0001). Conclusion: Within the limitations of this study, it could be demonstrated that surface roughness and enamel microhardness changes were influenced by the type, composition, and exposure time of the whitening product.
Collapse
|