1
|
Gad MM, Alalawi H, Al-Qarni FD, Al-Harbi FA. Denture relining using digital replication method: A dental technique. J Prosthodont 2024. [PMID: 38403847 DOI: 10.1111/jopr.13832] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Accepted: 02/01/2024] [Indexed: 02/27/2024] Open
Abstract
The aim of this report was to digitize traditional denture relining using a digital duplication method, in addition to assessing the wear resistance of three-dimensional (3D) printed denture teeth. A complete denture was relined using light body impression. The denture with impression was scanned yielding a standard tessellation language file that was designed to print the denture base and teeth. The printed teeth were fitted into the sockets of the printed denture base and then bonded using auto-polymerized acrylic resins, followed by finishing and polishing. Dentures were inserted and fit and occlusion were adjusted as needed, and the patient was scheduled for follow-up appointments at one week, three months, and six months. At each follow-up visit, dentures were scanned using a 3Shape E3 desktop scanner and scans were superimposed. The occlusal wear was assessed in reference to the first scan after the denture insertion visit. The accuracy of the intaglio surface of dentures was within clinically acceptable limits. The clinical evaluation of inserted dentures in terms of retention, occlusion, esthetic, and patient satisfaction was encouraging. Using digital duplication, conventional dentures could be relined. The advantages of digital records include eliminating polymerization dimensional changes, and reducing cost and clinical time by minimizing the number of visits, which is particularly helpful with geriatric patients.
Collapse
Affiliation(s)
- Mohammed M Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Haidar Alalawi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Faisal D Al-Qarni
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Fahad A Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| |
Collapse
|
2
|
Ellakany P, Madi M, Aly NM, Alshehri T, Alameer ST, Al-Harbi FA. Influences of Different CAD/CAM Ceramic Compositions and Thicknesses on the Mechanical Properties of Ceramic Restorations: An In Vitro Study. Materials (Basel) 2023; 16:ma16020646. [PMID: 36676383 PMCID: PMC9865408 DOI: 10.3390/ma16020646] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Revised: 12/24/2022] [Accepted: 12/26/2022] [Indexed: 05/14/2023]
Abstract
The aim of this study was to assess the influences of different CAD/CAM ceramic compositions and thicknesses on the surface roughness and hardness of ceramic restorations. Four different ceramics were used in the current study: lithium disilicate (LD), leucite reinforced (LE), advanced lithium disilicate (ALD), and zirconia-reinforced lithium silicate (ZLS). Each group included 30 specimens subdivided into three different ceramic thicknesses (0.5, 1 and 1.5 mm thicknesses). The microhardness was measured for all the specimens using a microhardness testing machine, while the surface roughness was measured using a non-contact optical profilometer at three intervals (before toothbrushing and after toothbrushing, with and without toothpaste). Three-way and two-way ANOVA were used to determine the factors influencing the surface roughness and microhardness. There was a significant difference in the surface roughness between the studied groups for all the thicknesses. The findings showed that ALD had the lowest surface roughness, while ZLS showed the highest surface roughness. Moreover, ALD, followed by ZLS, had the highest hardness, while LD and LE had the lowest hardness values. Regarding the thicknesses, both the 0.5 and 1 mm ceramic thicknesses showed a significantly lower surface roughness than the 1.5 mm thickness, while the 1.5 mm thickness showed a significantly higher microhardness than the 0.5 mm thickness. The surface roughness and hardness were significantly affected by the ceramic composition and type of filler. It is recommended to use 1.5 mm-thick ceramic materials for the fabrication of definitive full-coverage ceramic restorations, while veneers require 0.5 mm-thick materials. ALD is a promising CAD/CAM material that can be used for the fabrication of restorations with a proper strength in both anterior and posterior regions.
Collapse
Affiliation(s)
- Passent Ellakany
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
- Correspondence: ; Tel.: +966-547812107
| | - Marwa Madi
- Department of Preventive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| | - Nourhan M. Aly
- Department of Pediatric Dentistry and Dental Public Health, Faculty of Dentistry, Alexandria University, Alexandria 21527, Egypt
| | - Turki Alshehri
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| | - Shahad T. Alameer
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| | - Fahad A. Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| |
Collapse
|
3
|
Alaseef N, Albasarah S, Al Abdulghani H, Al-Harbi FA, Gad MM, Akhtar S, Khan SQ, Ateeq IS, Al-Qarni FD. CAD-CAM Fabricated Denture Base Resins: In Vitro Investigation of the Minimum Acceptable Denture Base Thickness. J Prosthodont 2022; 31:799-805. [PMID: 35102627 DOI: 10.1111/jopr.13486] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/25/2022] [Indexed: 01/04/2023] Open
Abstract
PURPOSE To investigate the influence of reducing material thickness on flexural properties of computer-aided design and computer-aided manufacturing (CAD-CAM) denture base resins. MATERIALS AND METHODS Four CAD-CAM denture base acrylic resin materials were selected; two were made via the subtractive method (AvaDent and IvoCad) and two were made with the additive method (FormLabs and NextDent). One heat-polymerized denture base material was used as a control. Specimens were fabricated with varying thicknesses (n = 10/group): 3.3 mm, 2.5 mm, 2 mm, or 1.5 mm. Flexural strength was evaluated via a three-point bending test. One- and two-way ANOVA were used for data analysis along with Tukey's post hoc comparison (α = 0.05). RESULTS Reducing the thickness of materials made via the subtractive method did not influence flexural strength up to 2 mm (p > 0.05). However, the difference was significant at a 1.5 mm thickness (p ˂ 0.001). For materials made via the additive method, NextDent specimens had no significant decrease in flexural strength when the thickness was reduced to 2 mm (p = 0.58). FormLabs specimens showed a significant decrease (p ˂ 0.001), although the values of flexural strength were clinically acceptable. During testing, specimens manufactured via the additive method at a 1.5 mm thickness bent without fracturing and were therefore excluded. All materials showed a reduction in elastic modulus as the thickness decreased (p ˂ 0.001). CONCLUSION Heat-polymerized, AvaDent, and IvoCad materials may be used for denture base fabrication at a minimum thickness of 1.5 mm. FormLabs and NextDent may be fabricated at a 2 mm minimum thickness, with clinically acceptable flexural properties.
Collapse
Affiliation(s)
- Nawarah Alaseef
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Sara Albasarah
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Hanan Al Abdulghani
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Fahad A Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Mohammed M Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Sultan Akhtar
- Department of Biophysics, Institute for Research and Medical Consultations (IRMC), Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Soban Q Khan
- Department of Dental Education, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Ijlal Shahrukh Ateeq
- Biomedical Engineering Department, College of Engineering, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Faisal D Al-Qarni
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| |
Collapse
|
4
|
Gad MM, Al-Harbi FA, Akhtar S, Fouda SM. 3D-Printable Denture Base Resin Containing SiO 2 Nanoparticles: An In Vitro Analysis of Mechanical and Surface Properties. J Prosthodont 2022; 31:784-790. [PMID: 35061921 DOI: 10.1111/jopr.13483] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Accepted: 01/17/2022] [Indexed: 01/04/2023] Open
Abstract
PURPOSE To evaluate the flexural strength (FS), impact strength (IS), surface roughness (Ra), and hardness of 3D-printed resin incorporating silicon dioxide nanoparticles (SNPs). MATERIALS AND METHODS A total of 320 acrylic specimens were fabricated with different dimensions according to test specifications and divided into a control group of heat denture base resin, and 3 test groups (80/test (n = 10) of unmodified, 0.25 wt%, and 0.5 wt% SNPs modified 3D-printed resin. 10,000 thermal cycles were performed to half of the fabricated specimens. FS, IS (Charpy impact), Ra, and hardness were evaluated and the collected data was analyzed with ANOVA followed by Tukey's post hoc test (α = 0.05). RESULTS Incorporating SNPs into 3D-printed resin significantly increased the FS, IS (at 0.5%) and hardness compared to unmodified 3D-printed resin (p < 0.001). However, the FS of pure 3D-printed and 3D/SNP-0.50% resin and IS of all 3D-printed resin groups were significantly lower than the control group (p < 0.0001). Hardness of 3D/SNP-0.25% and 3D/SNP-0.50% was significantly higher than control and unmodified 3D-printed resin (p < 0.0001), with insignificant differences between them. The Ra of all 3D-printed resin groups were significantly higher than control group (p < 0.001), while insignificant difference was found between 3D-printed groups. Thermal cycling significantly reduced FS and hardness for all tested groups, while for IS the reduction was significant only in the control and 3D/SNP-0.50% groups. Thermal cycling significantly increased Ra of the control group and unmodified 3D-printed resin (p < 0.001). CONCLUSION The addition of SNPs to 3D-printed denture base resin improved its mechanical properties while Ra was not significantly altered. Thermal cycling adversely affected tested properties, except IS of unmodified 3D-printed resin and 3D/SNP-0.25%, and Ra of modified 3D-printed resin.
Collapse
Affiliation(s)
- Mohammed M Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Fahad A Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Sultan Akhtar
- Department of Biophysics, Institute for Research and Medical Consultations (IRMC), Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Shaimaa M Fouda
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| |
Collapse
|
5
|
Al-Thobity AM, Alkhaltham N, Aldhafiri R, Almasoud NN, Al-Harbi FA, Khan SQ, Gad MM. Effect of Occlusal Splint Therapy on Condylar Movements Recorded Using an Electronic Pantograph: A Prospective Clinical Study. J Int Soc Prev Community Dent 2022; 12:532-539. [PMID: 36532322 PMCID: PMC9753922 DOI: 10.4103/jispcd.jispcd_96_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Revised: 07/26/2022] [Accepted: 08/11/2022] [Indexed: 01/25/2023] Open
Abstract
AIMS AND OBJECTIVE The effect of occlusal splint therapy on the muscle activity has been addressed in the literature. However, its effect on condylar movements in subjects with normal and abnormal occlusions has not yet been investigated. This prospective clinical study addressed the effect of occlusal splint therapy on condylar movements in subjects with normal and abnormal occlusions using an electronic pantograph. MATERIALS AND METHODS Two groups of subjects were included in this study. The first group included subjects with normal occlusion, whereas the subjects in the other group were diagnosed with abnormal occlusion. The occlusal splint was fabricated, adjusted clinically, and delivered for each subject. Condylar movements were recorded using a Cadiax Compact II electronic pantograph at baseline, 2-, 4-, and 6-month follow-up periods to assess sagittal condylar inclination (SCI), immediate mandibular lateral translation (IMLT), and progressive mandibular lateral translation (PMLT). The t-test, one-way analysis of variance (ANOVA), and two-way ANOVA were used to compare the parameters between the groups and to assess the time effect on these parameters (α = 0.05). RESULTS Twenty subjects were recruited for this study (n = 10). Among them, 12 were women and eight were men, with a mean age of 34 years. In each group, insignificant differences were reported for each tested parameter at baseline and during the follow-up periods (P > 0.05). However, when comparing the two groups, the only significant difference was found in the SCI during the 6-month follow-up period (P = 0.014). CONCLUSIONS Occlusal splints had an insignificant effect on the parameters SCI, IMLT, and PMLT up to 6 months of follow-up for subjects with normal or abnormal occlusion. SCI increased substantially in normal occlusion subjects compared with abnormal occlusion subjects during the 6-month follow-up period.
Collapse
Affiliation(s)
- Ahmad M Al-Thobity
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia,Address for correspondence: Dr. Ahmad M. Al-Thobity, Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia. E-mail:
| | - Nora Alkhaltham
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Reem Aldhafiri
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Naif N Almasoud
- Department of Preventive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Fahad A Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Soban Q Khan
- Department of Dental Education, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Mohammed M Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| |
Collapse
|
6
|
Alzaid M, AlToraibily F, Al-Qarni FD, Al-Thobity AM, Akhtar S, Ali S, Al-Harbi FA, Gad MM. The Effect of Salivary pH on the Flexural Strength and Surface Properties of CAD/CAM Denture Base Materials. Eur J Dent 2022; 17:234-241. [PMID: 35820440 PMCID: PMC9949971 DOI: 10.1055/s-0042-1749160] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022] Open
Abstract
OBJECTIVES This study aimed to evaluate the influence of different salivary pH on flexural strength, hardness, and surface roughness of computer-aided design and computer-aided manufacturing (CAD/CAM) milled and three-dimensional (3D)-printed denture base resins. METHODS One heat-polymerized, two CAD/CAM milled (IvoCad, AvaDent), and two 3D-printed (FormLabs, NextDent) denture base resins were fabricated and divided into five groups (n = 10) according to the solutions: three groups were immersed in different salivary pH (5.7, 7.0, or 8.3), one group was immersed in distilled water (DW) as a positive control, and one group had no immersion (negative control). All immersions were performed at 37°C for 90 days. Flexural strength, hardness, and surface roughness were measured before and after immersion. Data was analyzed with analysis of variance and post hoc Tukey's test (α = 0.05). RESULTS After immersion, all specimens had lower flexural strength values when compared with those with no immersion. Comparing the immersion groups, the highest flexural strength value (93.96 ± 3.18 MPa) was recorded with IvoCad after immersion in DW while the lowest value (60.43 ± 2.66 MPa) was recorded with NextDent after being immersed in 7.0 pH saliva. All specimens had significant decrease in hardness except IvoCad and AvaDent specimens where both presented the highest surface hardness (53.76 ± 1.60 Vickers hardness number [VHN]) after immersion in DW while NextDent showed the lowest hardness value (24.91 ± 2.13 VHN) after being immersed in 8.3 pH saliva. There was statistically significant difference between the baseline and different artificial salivary pH solutions in terms of surfaces roughness, with the highest surface roughness were found in 3D-printed resin materials. CONCLUSION After exposure to artificial saliva with different salivary pH, the milled CAD/CAM denture base resins showed higher flexural strength, hardness, and lesser surface roughness than conventional and 3D-printed denture base resins.
Collapse
Affiliation(s)
- Maryam Alzaid
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Fatemah AlToraibily
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Faisal D. Al-Qarni
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Ahmad M. Al-Thobity
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Sultan Akhtar
- Department of Biophysics, Institute for Research and Medical Consultations (IRMC), Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Saqib Ali
- Department of Biomedical Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Fahad A. Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Mohammed M. Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia,Address for correspondence Mohammed M. Gad, BDS, MSc Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal UniversityDammam 31441Kingdom of Saudi Arabia
| |
Collapse
|
7
|
Fouda SM, Gad MM, Abualsaud R, Ellakany P, AlRumaih HS, Khan SQ, Akhtar S, Al-Qarni FD, Al-Harbi FA. Flexural Properties and Hardness of CAD-CAM Denture Base Materials. J Prosthodont 2022; 32:318-324. [PMID: 35567362 DOI: 10.1111/jopr.13535] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2022] [Accepted: 05/02/2022] [Indexed: 11/28/2022] Open
Abstract
PURPOSE To compare flexural strength, elastic modulus, and surface hardness of CAD-CAM milled, 3D-printed, and heat-polymerized denture base resins. MATERIALS AND METHODS A total of 120 specimens were fabricated from heat-polymerized acrylic resin (HP), milled resin (Avadent and IvoCad), and 3D-printed resin (ASIGA, FormLabs, and NextDent). The specimens were divided into 6 groups according to the type of denture base material n = 20/material, (10/flexural properties and 10/hardness). Flexural strength and elastic modulus of the specimens were evaluated by 3-point bending test and surface hardness by Vickers hardness test. To test flexural properties, the specimens were fabricated according to ISO 20795-1:2013 standards (64×10×3.3 ±0.2 mm). The dimensions for hardness test were 15×10×2.5 ±0.2 mm. Scanning electron microscope was used to evaluate the surface morphology of the fractured specimens. The means and standard deviations were calculated, followed by one-way ANOVA and Tukey post-hoc test (α = 0.05). RESULTS Milled resins showed significantly higher values for flexural strength, elastic modulus, and surface hardness, followed by HP then 3D-printed resins (P<0.001). In between milled groups, flexural strength of AvaDent was significantly higher than IvoCad (P<0.001), while elastic modulus and hardness didn't show significant difference. In between 3D-printed resins, ASIGA showed the highest flexural strength and elastic modulus, insignificantly with FormLabs (P = 0.595) and significantly with NextDent (P = 0.008). ASIGA also showed significantly the highest hardness among the 3D-printed groups. No significant difference was found between FormLabs and NextDent flexural strength (P = 0.357), elastic modulus (P = 1.00) and surface hardness (P = 0.987). CONCLUSION CAD-CAM milled resins had greater flexural properties and hardness compared to heat-polymerized acrylic resin and 3D-printed resins. Although 3D-printed samples showed the lowest values of tested properties, the flexural strength and modulus were above the clinically acceptable values. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Shaimaa M Fouda
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Mohammed M Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Reem Abualsaud
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Passent Ellakany
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Hamad S AlRumaih
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Soban Q Khan
- Department of Clinical Affairs, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Sultan Akhtar
- Department of Biomedical Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Faisal D Al-Qarni
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Fahad A Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| |
Collapse
|
8
|
Abstract
Background: This study aimed to determine whether people living in the Eastern Region of Saudi Arabia would prefer to continue the practice of physical distancing after the coronavirus disease 2019 (COVID-19) pandemic or to return to their previous way of life. Methods: This cross-sectional study was conducted from August 2020 to October 2020 in the Eastern Region of Saudi Arabia. A pre-tested questionnaire was sent electronically through social media. Data on participants' demographics and their perspectives regarding post-pandemic physical distancing were collected. The calculated sample size was 1,066; however, the total number of responses included in the analysis was 989. Results: The average age of the participants was 31.15±11.93 years. There were 435 men and 554 women in the study. Participants showed significantly high levels of disagreement with statements indicating that they were willing to use public transportation (61%), attend social gatherings (36%), and hug relatives or colleagues (40%) after the pandemic ( p<0.001); however, 43% agreed that they would spend time with family or friends ( p<0.001). The level of education was also found to be significantly related to the responses, and the level of disagreement increased as the level of education increased ( p<0.001). Conclusions: One-third of the study participants planned to continue engaging in physical distancing even after the current pandemic and if the COVID-19 related restriction will remain in place for longer, there is chance to increase in this proportion. However, it cannot be concluded whether or not this behavior will prevail in the long run, after the ease in restrictions. If so, it may greatly affect some businesses and perhaps some social norms and values as well.
Collapse
Affiliation(s)
- Soban Qadir Khan
- Department of Dental Education, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Jehan Al-Humaid
- Department of Preventive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Faraz Ahmed Farooqi
- Department of Dental Education, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Mohammed M Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Muhanad Al-Hareky
- Department of Preventive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Faisal Al-Onaizan
- Department of Restorative Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Fahad A Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| |
Collapse
|
9
|
Fouda SM, Gad MM, Ellakany P, Al Ghamdi MA, Khan SQ, Akhtar S, Al Eraky DM, Al-Harbi FA. Effect of Low Nanodiamond Concentrations and Polymerization Techniques on Physical Properties and Antifungal Activities of Denture Base Resin. Polymers (Basel) 2021; 13:polym13244331. [PMID: 34960883 PMCID: PMC8708888 DOI: 10.3390/polym13244331] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Revised: 11/29/2021] [Accepted: 12/06/2021] [Indexed: 12/31/2022] Open
Abstract
Background: Denture base resin has some drawbacks. This study investigated the impact of nanodiamonds (ND) and autoclave polymerization on the surface characteristics, translucency, and Candida albicans adherence in polymethyl methacrylate (PMMA) denture base resin after thermocycling. Methods: Heat-polymerized PMMA discs (15 × 2 mm) with a total sample size n = 160 were studied. Specimens were categorized into two main groups (N = 80): conventional water-bath-polymerized PMMA (CP/PMMA) and autoclave-polymerized PMMA (AP/PMMA). Each group was subdivided according to the ND concentration into four groups (n = 20): unmodified PMMA as a control, and 0.1%, 0.25%, and 0.5% ND–PMMA. Scanning electron microscopy (SEM) was used to inspect the morphology of the ND and the ND–PMMA mixtures before heat polymerization. The specimens were exposed to thermal cycling (5000 cycles at 5 and 55 °C), then surface roughness was measured with a non-contact optical interferometric profilometer, contact angle with an automated goniometer, and translucency using a spectrophotometer. Colony-forming units (CFU) were used to determine the adherence of Candida albicans cells to the specimens. ANOVA and Tukey post hoc tests for pairwise comparison were utilized for the statistical analysis (α = 0.05). Results: Surface roughness was significantly reduced with ND addition to CP/PMMA (p ˂ 0.001), while the reduction was not statistically significant in AP/PMMA (p = 0.831). The addition of ND significantly reduced the contact angle, translucency, and Candida albicans count of CP/PMMA and AP/PMMA (p ˂ 0.001). The incorporation of ND in conjunction with autoclave polymerization of PMMA showed significant reduction in all tested properties (surface roughness, contact angle and Candida albicans adherence) except translucency (p = 0.726). Conclusions: ND addition to PMMA and autoclave polymerization improved the surface properties with respect to antifungal activities, while the translucency was adversely affected.
Collapse
Affiliation(s)
- Shaimaa M. Fouda
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia; (M.M.G.); (P.E.); (M.A.A.G.); (F.A.A.-H.)
- Correspondence:
| | - Mohammed M. Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia; (M.M.G.); (P.E.); (M.A.A.G.); (F.A.A.-H.)
| | - Passent Ellakany
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia; (M.M.G.); (P.E.); (M.A.A.G.); (F.A.A.-H.)
| | - Maram A. Al Ghamdi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia; (M.M.G.); (P.E.); (M.A.A.G.); (F.A.A.-H.)
| | - Soban Q. Khan
- Department of Dental Education, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia;
| | - Sultan Akhtar
- Department of Biophysics, Institute for Research and Medical Consultations, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia;
| | - Doaa M. Al Eraky
- Department of Biomedical Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia;
| | - Fahad A. Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia; (M.M.G.); (P.E.); (M.A.A.G.); (F.A.A.-H.)
| |
Collapse
|
10
|
AlEraky DM, Madi M, El Tantawi M, AlHumaid J, Fita S, AbdulAzeez S, Borgio JF, Al-Harbi FA, Alagl AS. Predominance of non- Streptococcus mutans bacteria in dental biofilm and its relation to caries progression. Saudi J Biol Sci 2021; 28:7390-7395. [PMID: 34867042 PMCID: PMC8626303 DOI: 10.1016/j.sjbs.2021.08.052] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2021] [Revised: 08/13/2021] [Accepted: 08/15/2021] [Indexed: 12/26/2022] Open
Abstract
This study aims to assess differences in biofilm bacterial composition between patients with low and high caries. Patients without a medical problem and with no history of antibiotic use, mouth wash or fluoride application in the previous 3 months were recruited. Caries was recorded at cavitation level; score was calculated by a national mean (dmft of 4.8 and DMFT of 2.7). Pooled biofilm samples were collected from mesial, distal, buccal, lingual, and occlusal surfaces. Based on caries experience, individuals were classified into low and high caries and both groups were compared regarding bacteria identified using 16S rRNA gene sequencing, and molecular phylogenetic analysis of the isolates was performed. A total of twenty seven randomly selected samples with low (n = 13) and high (n = 14) caries. Identification of oral bacteria was performed using 16S rRNA sequence, Rothia mucilaginosa and R. aeria were identified in low caries individuals, while R. dentocariosa was detected in high caries individuals. Two Streptococcus spp. were identified only in low caries S. salivarius and S. gordonii whereas S. sanguinis, S. mitis, S. sinensis, S. rubneri, S. vestibularis, S. cristatus and S. massiliensis were identified only in individuals with high caries. This study revealed the absence of R. mucilaginosa in the high caries subjects and its coexistence with the low caries subjects. Streptococcus mutans was insignificant contributor of caries among samples, while, Streptococcus sanguinis was the main constituent of high caries Saudi patients.
Collapse
Affiliation(s)
- Doaa M AlEraky
- Department of Biomedical Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Marwa Madi
- Department of Preventive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Maha El Tantawi
- Department of Pediatric Dentistry and Dental Public Health, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| | - Jehan AlHumaid
- Department of Preventive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Sarah Fita
- Department of Preventive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Sayed AbdulAzeez
- Department of Genetic Research, Institute for Research and Medical Consultations (IRMC), Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - J Francis Borgio
- Department of Genetic Research, Institute for Research and Medical Consultations (IRMC), Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia.,Department of Epidemic Diseases Research, Institute for Research and Medical Consultations (IRMC), Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Fahad A Al-Harbi
- Department of Substitutive Dental Science, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Adel S Alagl
- Department of Preventive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| |
Collapse
|
11
|
Gad MM, Fouda SM, Abualsaud R, Alshahrani FA, Al-Thobity AM, Khan SQ, Akhtar S, Ateeq IS, Helal MA, Al-Harbi FA. Strength and Surface Properties of a 3D-Printed Denture Base Polymer. J Prosthodont 2021; 31:412-418. [PMID: 34347351 DOI: 10.1111/jopr.13413] [Citation(s) in RCA: 60] [Impact Index Per Article: 20.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/29/2021] [Indexed: 11/28/2022] Open
Abstract
PURPOSE This in vitro study evaluated the flexural strength, impact strength, hardness, and surface roughness of 3D-printed denture base resin subjected to thermal cycling treatment. MATERIALS AND METHODS According to ISO 20795-1:2013 standards, 120 acrylic resin specimens (40/flexural strength test, 40/impact strength, and 40/surface roughness and hardness test, n = 10) were fabricated and distributed into two groups: heat-polymerized; (Major.Base.20) as control and 3D-printed (NextDent) as experimental group. Half of the specimens of each group were subjected to 10,000 thermal cycles of 5 to 55°C simulating 1 year of clinical use. Flexural strength (MPa), impact strength (KJ/m2 ), hardness (VHN), and surface roughness (μm) were measured using universal testing machine, Charpy's impact tester, Vickers hardness tester, and profilometer, respectively. Data were analyzed by ANOVA and Tukey honestly significant difference (HSD) test (α = 0.05). RESULTS The values of flexural strength (MPa) were 86.63 ± 1.0 and 69.15 ± 0.88; impact strength (KJ/m2 )-6.32 ± 0.50 and 2.44 ± 0.31; hardness (VHN)-41.63 ± 2.03 and 34.62 ± 2.1; and surface roughness (μm)-0.18 ± 0.01 and 0.12 ± 0.02 for heat-polymerized and 3D-printed denture base materials, respectively. Significant differences in all tested properties were recorded between heat-polymerized and 3D-printed denture base materials (P < 0.001). Thermal cycling significantly lowered the flexural strength (63.93 ± 1.54 MPa), impact strength (2.40 ± 0.35 KJ/m2 ), and hardness (30.17 ± 1.38 VHN) of 3D-printed resin in comparison to thermal cycled heat-polymerized resin, but surface roughness showed non-significant difference (p = 0.262). CONCLUSION 3D-printed resin had inferior flexural strength, impact strength, and hardness values than heat-polymerized resin, but showed superior surface roughness. Temperature changes (thermal cycling) significantly reduced the hardness and flexural strength and increased surface roughness, but did not affect the impact strength.
Collapse
Affiliation(s)
- Mohammed M Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Shaimaa M Fouda
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Reem Abualsaud
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Faris A Alshahrani
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Ahmad M Al-Thobity
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Soban Q Khan
- Department of Dental Education, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Sultan Akhtar
- Department of Biophysics, Institute for Research and Medical Consultations (IRMC), Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Ijlal Shahrukh Ateeq
- Biomedical Engineering department, College of Engineering, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Mohamed A Helal
- Department of Removable Prosthodontics, Faculty of Dentistry, Al-Azhar University, Cairo, Egypt
| | - Fahad A Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| |
Collapse
|
12
|
Gad MM, Rahoma A, Khan ZA, Al-Thobity AM, Abualsaud R, Alkaltham N, Akhtar S, Ateeq IS, Al-Harbi FA. Closed Repair Technique: Innovative Surface Design for Polymethylmethacrylate Denture Base Repair. J Prosthodont 2021; 31:257-265. [PMID: 34318547 DOI: 10.1111/jopr.13412] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/22/2021] [Indexed: 11/26/2022] Open
Abstract
PURPOSE This study aimed to evaluate the repair strength of a newly introduced repair technique involving zero-gap repair width. MATERIALS AND METHODS A total of 36 rectangular prism specimens with dimensions of 64 × 10 × 3.3 mm were prepared from heat-polymerized acrylic resin. Nine specimens were kept intact. The other specimens were sectioned into halves and modified to create repair gaps of 2.5-mm beveled (2.5B) as control, 0-mm beveled (ZB), and 0-mm inverse bi-beveled (ZIBB). The ZIBB group was prepared with a V-shaped internal groove on both halves (repair tunnel), while the intaglio and cameo surfaces were kept intact except for two small holes at the cameo surface for repair resin injection. The 2.5B and ZB groups were repaired conventionally while the ZIBB group was repaired by injecting repair resin into the tunnel through one of the holes until excess material oozed from the other hole. Repaired specimens were thermally cycled at 5 and 55°C for 10,000 cycles with 1 min dwell time. A 3-point bending test was conducted using a universal testing machine for flexural strength and elastic modulus measurement. Kruskal-Wallis/Mann-Whitney tests and ANOVA/post hoc Tukey tests were applied for data analysis (α = 0.05). RESULTS The flexural strength of repaired specimens was substantially lower than that of intact specimens, and significant differences were present between repaired groups (p ˂ 0.05). ZB and ZIBB had higher flexural strength (p ˂ 0.001) and elastic modulus (p ˂ 0.05) than 2.5B. Among the ZB and ZIBB groups, ZB showed the highest flexural strength, and ZIBB had the highest elastic modulus. CONCLUSION The closed repair technique improved the flexural strength and elastic modulus of repaired acrylic denture base.
Collapse
Affiliation(s)
- Mohammed M Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Ahmed Rahoma
- Department of Restorative Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Zahid A Khan
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Ahmad M Al-Thobity
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Reem Abualsaud
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Nora Alkaltham
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Sultan Akhtar
- Department of Biophysics, Institute for Research and Medical Consultations (IRMC), Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Ijlal Shahrukh Ateeq
- Biomedical Engineering department, College of Engineering, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Fahad A Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| |
Collapse
|
13
|
Gad MM, Abualsaud R, Alqarawi FK, Emam ANM, Khan SQ, Akhtar S, Mahrous AA, Al-Harbi FA. Translucency of nanoparticle-reinforced PMMA denture base material: An in-vitro comparative study. Dent Mater J 2021; 40:972-978. [PMID: 33883327 DOI: 10.4012/dmj.2020-296] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The aim of this study was to assess the translucency of denture base acrylic resin reinforced with zirconium dioxide (ZrO2NPs), silicon dioxide (SiO2NPs), and diamond (DNPs) nanoparticles. A total of 130 heat-polymerized acrylic discs (15×2.5 mm) were fabricated conventionally and divided into control and experimental groups according to nanoparticle type and concentration (0.5, 1, 1.5, and 2.5 wt%). Unmodified acrylic resin specimens served as control. All specimens were thermocycled (5,000 cycles). Translucency was measured using a spectrophotometer. ANOVA and post-hoc Turkeys' test were used for data analysis at α=0.05. The translucency of modified PMMA was significantly lower than control (p<0.05) except 0.5% ZrO2NPs and SiO2NPs (p>0.05) which exhibited the highest translucency values among modified groups. As the NPs concentration increased, the translucency decreased and the lowest value was seen with 2.5% DNPs (1.18±0.10). The addition of ZrO2NPs, SiO2NPs, and DNPs into denture base resin decreased the translucency.
Collapse
Affiliation(s)
- Mohammed M Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University
| | - Reem Abualsaud
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University
| | - Firas K Alqarawi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University
| | - Abdel-Naser M Emam
- Department of Removable Prosthodontics, Faculty of Dental Medicine, Al-Azhar University
| | - Soban Q Khan
- Department of Dental Education, College of Dentistry, Imam Abdulrahman Bin Faisal University
| | - Sultan Akhtar
- Department of Biophysics, Institute for Research and Medical Consultations, Imam Abdulrahman Bin Faisal University
| | - Amr A Mahrous
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University
| | - Fahad A Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University
| |
Collapse
|
14
|
Gad MM, Abualsaud R, Fouda SM, Rahoma A, Al-Thobity AM, Khan SQ, Akhtar S, Al-Harbi FA. Effects of Denture Cleansers on the Flexural Strength of PMMA Denture Base Resin Modified with ZrO 2 Nanoparticles. J Prosthodont 2020; 30:235-244. [PMID: 32783226 DOI: 10.1111/jopr.13234] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/07/2020] [Indexed: 12/01/2022] Open
Abstract
PURPOSE The additions of zirconium oxide nanoparticles (nano-ZrO2 ) to denture base materials have produced nanocomposites with satisfactory properties, although there is a lack of research investigating the effects of denture cleansers on these materials. This study aimed to evaluate the effect of denture cleansers on the flexural strength of denture base materials modified with nano-ZrO2 . MATERIALS AND METHODS A total of 270 specimens were fabricated from pure and nano-ZrO2 reinforced acrylic resins at 2.5% and 5%, resulting in 3 main groups. The groups were further divided into subgroups (n = 10) according to immersion solution (distilled water, Corega, sodium hypochlorite, and Renew) and immersion duration. Flexural strength was measured at baseline (T0 ) in distilled water and after 180 and 365 days of immersion (T1 and T2 ) in denture cleansers. Data were collected and analyzed using repeated measure ANOVA and Bonferroni post hoc tests (α = 0.05). RESULTS The flexural strength of the nano-ZrO2 modified denture base material decreased significantly after immersion in different denture cleansers at different immersion durations in comparison to baseline (T0 ) (p < 0.001). Sodium hypochlorite showed the highest reduction in flexural strength followed by Corega, while Renew cleansing solution resulted in the least change. CONCLUSION Denture cleansers can significantly affect the flexural strength of nano-ZrO2 modified denture base materials and thus should be used cautiously.
Collapse
Affiliation(s)
- Mohammed M Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam, 31441, Saudi Arabia
| | - Reem Abualsaud
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam, 31441, Saudi Arabia
| | - Shaimaa M Fouda
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam, 31441, Saudi Arabia
| | - Ahmed Rahoma
- Department of Restorative Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam, 31441, Saudi Arabia
| | - Ahmad M Al-Thobity
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam, 31441, Saudi Arabia
| | - Soban Q Khan
- Department of Clinical Affairs, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam, 31441, Saudi Arabia
| | - Sultan Akhtar
- Department of Biophysics, Institute for Research and Medical Consultations, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam, 31441, Saudi Arabia
| | - Fahad A Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam, 31441, Saudi Arabia
| |
Collapse
|
15
|
Gad MM, Abualsaud R, Al-Thobity AM, Baba NZ, Al-Harbi FA. Influence of Addition of Different Nanoparticles on the Surface Properties of Poly(methylmethacrylate) Denture Base Material. J Prosthodont 2020; 29:422-428. [PMID: 32233047 DOI: 10.1111/jopr.13168] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2020] [Revised: 03/07/2020] [Accepted: 03/19/2020] [Indexed: 11/30/2022] Open
Abstract
PURPOSE To evaluate and compare the surface properties (roughness and hardness) of poly(methylmethacrylate) denture base material modified with zirconium dioxide (ZNPs), silicon dioxide (SNPs), and diamond (DNPs) nanoparticles. MATERIALS AND METHODS Two hundred sixty heat-polymerized acrylic resin disks (15 × 2 mm) were prepared. ZNPs, SNPs, and DNPs were added in concentrations of 0%, 0.5%, 1.0%, 2.5%, and 5.0% by weight of acrylic powder. This yielded a total of 13 groups for each test according to filler type and concentration (n = 10/group). The control group was made of pure acrylic. A mechanical polisher was used to standardize specimens' surfaces before testing. A profilometer and Vickers hardness indenter were used to test the surface roughness and hardness, respectively. ANOVA and Tukey post hoc tests were used for data analysis (α = 0.05). RESULTS In comparison to control, results showed a nonsignificant increase in surface roughness (Ra ) of acrylic material after the addition of 0.5% nanoparticles (ZNPs p = 0.168, SNPs p = 0.166, and DNPs p = 0.177), while a significant increase was seen with all other concentrations (p ˂ 0.05). Ra values of ZNP and DNP groups were significantly higher than those of the SNPs group (p < 0.001). The addition of any of the fillers to acrylic denture base materials significantly increased the hardness (p ˂ 0.05), with ZNPs and DNPs having values lower than those of the SNPs group (p < 0.001). CONCLUSIONS Although nanofiller addition increased the hardness of denture base material, Ra was adversely affected when the concentration exceeded 0.5%. Therefore, 0.5% is suggested to be the most appropriate ratio to improve hardness with acceptable Ra .
Collapse
Affiliation(s)
- Mohammed M Gad
- Lecturer, Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Reem Abualsaud
- Assistant Professor, Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Ahmad M Al-Thobity
- Associate Professor, Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Nadim Z Baba
- Professor, Advanced Education Program in Implant Dentistry, Loma Linda University, School of Dentistry, Loma Linda, CA
| | - Fahad A Al-Harbi
- Professor, Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| |
Collapse
|
16
|
Gad MM, Rahoma A, Abualsaud R, Al-Thobity AM, Akhtar S, Siddiqui IA, Al-Harbi FA. Influence of artificial aging and ZrO2 nanoparticle-reinforced repair resin on the denture repair strength. J Clin Exp Dent 2020; 12:e354-e362. [PMID: 32382385 PMCID: PMC7195688 DOI: 10.4317/jced.56610] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2019] [Accepted: 01/27/2020] [Indexed: 11/05/2022] Open
Abstract
Background The purpose of this study was to evaluate the effect of aging process on the tensile strength (TS) of repaired acrylic denture base using ZrO2 nanoparticles (nano-ZrO2)-reinforced autopolymerized resin. Material and Methods A total of 240 heat-polymerized acrylic resin specimens (n=10) were prepared and sectioned creating 2 mm-repair-gap. Autopolymerized acrylic resin, pure and modified with 2.5, 5, and 7.5wt% nano-ZrO2 were used for specimens repair. TS of repaired specimens were measured using the universal testing machine after water immersion at 37oC for 2, 7 and 30 days. At each time interval, half the immersed specimens underwent thermo-cycling aging process (5000 cycles at 5/55°C) before TS testing. One-way ANOVA and Tukey-Kramer multiple-comparison tests were used for data analysis at α=0.05. Results Aging process for all groups showed significant differences in TS between unreinforced and nano-ZrO2 reinforced groups (p<0.05). Within immersed nano-ZrO2-reinforced specimens, 5% group immersed for 30-days showed the highest significant TS value (p<0.05). With regards to thermocycling, 5% group showed the highest TS values after 2-days and 30-days groups while after 7-days, significant differences were found between 2.5% group and 5% and 7.5% groups (p<0.05). SEM images analysis displayed the ductile fracture type for nano-ZrO2 reinforced groups. Conclusions In summary, 5.0%-nano-ZrO2 addition to repair resin showed an improvement in tensile strength of repaired acrylic resin with different aging processes. Key words:Acrylic resins, denture repair, tensile strength, thermocycling, water storage, zirconium oxide nanoparticle.
Collapse
Affiliation(s)
- Mohammed M Gad
- MSc. College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31411, Saudi Arabia
| | - Ahmed Rahoma
- PhD. College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31411, Saudi Arabia
| | - Reem Abualsaud
- DScD. College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31411, Saudi Arabia
| | - Ahmad M Al-Thobity
- FRCD(C). College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31411, Saudi Arabia
| | - Sultan Akhtar
- PhD. Department of Biophysics, Institute for Research and Medical Consultations (IRMC), Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31411, Saudi Arabia
| | - Intisar A Siddiqui
- MSc. College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31411, Saudi Arabia
| | - Fahad A Al-Harbi
- DScD, FACP. College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31411, Saudi Arabia
| |
Collapse
|
17
|
Gad MM, Rahoma A, Abualsaud R, Al-Thobity AM, Akhtar S, Helal MA, Al-Harbi FA. Impact of different surface treatments and repair material reinforcement on the flexural strength of repaired PMMA denture base material. Dent Mater J 2020; 39:471-482. [PMID: 32092720 DOI: 10.4012/dmj.2018-436] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
This study assessed the impact of surface treatments and repair resin reinforcement with zirconium oxide nano-particles (nano-ZrO2) on flexural strength (FS) of repaired denture base. A total of 320 heat-polymerized acrylic resin specimens were prepared and sectioned creating 2-mm gap. According to repair surface treatment, specimens were distributed into four groups: I) methyl methacrylate (M); II) alumina-blasted (AB); III) AB+silane coupling agent (SC); and IV) AB+methacrylate based composite bonding agent (MA). Groups were subdivided into 4 (n=20) according to nano-ZrO2 concentration (0, 2.5, 5, 7.5 wt%). Half the specimens were thermo-cycled before testing. FS was determined by three-point bending test. Statistical analysis was done using ANOVA and Tukey-Kramer multiple comparison tests, with α=0.05. Alumina-blasting+(SC) or (MA) significantly increased FS of repaired specimens compared to control (p<0.05). All surface-treated specimens combined with nano-ZrO2 reinforced repair resin significantly increased FS.
Collapse
Affiliation(s)
- Mohammed M Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University
| | - Ahmed Rahoma
- Department of Restorative Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University
| | - Reem Abualsaud
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University
| | - Ahmad M Al-Thobity
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University
| | - Sultan Akhtar
- Department of Biophysics, Institute for Research and Medical Consultations, Imam Abdulrahman Bin Faisal University
| | - Mohamed A Helal
- Department of Removable Prosthodontics, Faculty of Dentistry, Al-Azhar University
| | - Fahad A Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University
| |
Collapse
|
18
|
Gad MM, Abualsaud R, Al-Thobity AM, Al-Abidi KS, Khan SQ, Abdel-Halim MS, Al-Harbi FA, El Zayat M, Fouda SM. Prevalence of partial edentulism and RPD design in patients treated at College of Dentistry, Imam Abdulrahman Bin Faisal University, Saudi Arabia. Saudi Dent J 2020; 32:74-79. [PMID: 32071535 PMCID: PMC7016229 DOI: 10.1016/j.sdentj.2019.07.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2019] [Revised: 07/08/2019] [Accepted: 07/09/2019] [Indexed: 11/30/2022] Open
Abstract
This study aimed to investigate the prevalence of partial edentulism, RPD type, design, and components and their frequency of use by patients at the prosthodontic clinics of the College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia. The prepared surveys, laboratory authorization forms, and images of the RPD metal frameworks on casts were used for data collection. Two calibrated investigators studied the digital photographs to identify the Kennedy classification, type of RPD, major connector, clasp assembly, and other details. Data was collected and analyzed statistically. The results showed that the most common class of partial edentulism was Kennedy class I, whereas class IV was the least (p < 0.001). Sixty two percent of fabricated RPDs had metal frameworks, whereas 37.2% were frameless. RPI was the most frequently used clasp assembly (38.9%), a significant finding in Kennedy class I(p < 0.01). The maxillary anteroposterior palatal strap and mandibular lingual plate were the most commonly used major connectors, at 41.2% and 60.8%, respectively. Conclusions: Simple RPD design that accomplishes the treatment objectives as well as proper communication with a well-trained dental technician would promote the success of RPDs.
Collapse
Affiliation(s)
- Mohammed M Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31411, Saudi Arabia
| | - Reem Abualsaud
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31411, Saudi Arabia
| | - Ahmad M Al-Thobity
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31411, Saudi Arabia
| | - Khalid S Al-Abidi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31411, Saudi Arabia
| | - Soban Q Khan
- Department of Clinical Affairs, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31411, Saudi Arabia
| | - Mohamed S Abdel-Halim
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31411, Saudi Arabia
| | - Fahad A Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31411, Saudi Arabia
| | - Mai El Zayat
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31411, Saudi Arabia
| | - Shaimaa M Fouda
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31411, Saudi Arabia
| |
Collapse
|
19
|
Gad MMA, Abualsaud R, Al-Thobity AM, Almaskin DF, AlZaher ZA, Abushowmi TH, Qaw MS, Akhtar S, Al-Harbi FA. Effect of SiO2 Nanoparticles Addition on the Flexural Strength of Repaired Acrylic Denture Base. Eur J Dent 2020; 14:19-23. [PMID: 31955401 PMCID: PMC7069758 DOI: 10.1055/s-0039-1701076] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Objective
The objective of this study was to evaluate the effect of nano-SiO
2
addition on the flexural strength (FS) of repaired acrylic denture base.
Materials and Methods
Heat-polymerized acrylic resin specimens were fabricated in dimensions of (65 × 10 × 2.5 ± 0.1 mm
3
) and then sectioned and prepared, creating repair gap with butt (90 degrees) and bevel (45 degrees) repair surface designs forming two main groups according to joint design. Further subdivision was done into four groups (
n
= 10) according to nano-SiO
2
concentration: one unmodified group and three modified groups (0.25, 0.5, and 0.75 wt %) in the autopolymerized repair resin. Each pair of a specimen was assembled in a mold and repaired according to manufacturer’s recommendations.
Statistical Analysis
Three-point bending test was done to measure FS, followed by scanning electron microscope (SEM) examination for fracture surface analysis. Data were analyzed using ANOVA and Tukey’s post hoc test (α = 0.05).
Results
The addition of nano-SiO
2
significantly improved FS of repaired acrylic resin in comparison to the unmodified group (
p
˂ 0.05). For butt joint, significant differences between nano-SiO
2
reinforced groups were noticed (
p
˂ 0.05), while reinforced beveled groups did not differ significantly (
p
˃ 0.05). Bevel design remarkably increased FS compared with butt design per respective filler concentration. From the SEM images, improved FS was presented with a homogeneous distribution of nano-SiO
2
within polymethyl methacrylate.
Conclusion
Nano-SiO
2
addition to repair resin and 45 degree-beveled repair surface increased FS of repaired acrylic resin.
Collapse
Affiliation(s)
- Mohammed Moustafa Ahmed Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Reem Abualsaud
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Ahmad M Al-Thobity
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Danah F Almaskin
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Zahra A AlZaher
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Tahani H Abushowmi
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Masoumah S Qaw
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Sultan Akhtar
- Department of Biophysics, Institute for Research and Medical Consultations, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Fahad A Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| |
Collapse
|
20
|
Abushowmi TH, AlZaher ZA, Almaskin DF, Qaw MS, Abualsaud R, Akhtar S, Al-Thobity AM, Al-Harbi FA, Gad MM, Baba NZ. Comparative Effect of Glass Fiber and Nano-Filler Addition on Denture Repair Strength. J Prosthodont 2019; 29:261-268. [PMID: 31696582 DOI: 10.1111/jopr.13124] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/04/2019] [Indexed: 11/28/2022] Open
Abstract
PURPOSE To evaluate and compare the effects of glass fiber (GF), Zirconium oxide nanoparticles (nano-ZrO2 ), and silicon dioxide nanoparticles (nano-SiO2 ) addition on the flexural strength and impact strength of repaired denture base material. MATERIALS AND METHODS Heat-polymerized acrylic resin specimens were fabricated. All specimens were sectioned centrally and beveled creating 2.5 mm repair gap except for 10 controls. Specimen grouping (n = 10/group) was done according to filler concentration of 0%, 0.25%, 0.5%, and 0.75% of auto-polymerized acrylic powder. Modified resin was mixed, packed in the repair gap, polymerized, finished and polished. Three-point bending test and Charpy type impact testing were done. Data were analyzed using one-way-ANOVA and Post-Hoc Tukey test (α = 0.05). RESULTS All additives significantly increased flexural strength and impact strength (p < 0.05). Within the modified subgroups, no significant differences were found for GF. Significant increase for nano-ZrO2 and significant decrease for nano-SiO2 as the concentration of additive increased were noted for both flexural strength and impact strength. Highest flexural strength was found with 0.75%-nano-ZrO2 (69.59 ± 2.52MPa) and the lowest was found with 0.75%-nano-SiO2 (53.82 ± 3.10MPa). The 0.25%-nano-SiO2 showed the highest impact strength value (2.54 ± 0.21 kJ/m2 ) while the lowest impact strength value was seen with 0.75%-nano-SiO2 (1.54 ± 0.17 kJ/m2 ). CONCLUSION Nano-filler effect was concentration dependent and its addition to repair resin increased the flexural and impact strengths. The incorporation of 0.75%-ZrO2 or 0.25%-SiO2 into repair resin proved to be a promising technique to enhance repair strength and avoid repeated fractures.
Collapse
Affiliation(s)
- Tahani H Abushowmi
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Zahra A AlZaher
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Danah F Almaskin
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Masoumah S Qaw
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Reem Abualsaud
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam, 31411, Saudi Arabia
| | - Sultan Akhtar
- Department of Biophysics, Institute for Research and Medical Consultations, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam, 31411, Saudi Arabia
| | - Ahmad M Al-Thobity
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam, 31411, Saudi Arabia
| | - Fahad A Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam, 31411, Saudi Arabia
| | - Mohammed M Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam, 31411, Saudi Arabia
| | - Nadim Z Baba
- Advanced Specialty Education Program in Prosthodontics, Loma Linda University, School of Dentistry, CA
| |
Collapse
|
21
|
Fouda SM, Gad MM, Ellakany P, Al-Thobity AM, Al-Harbi FA, Virtanen JI, Raustia A. The effect of nanodiamonds on candida albicans adhesion and surface characteristics of PMMA denture base material - an in vitro study. J Appl Oral Sci 2019; 27:e20180779. [PMID: 31691740 PMCID: PMC6831028 DOI: 10.1590/1678-7757-2018-0779] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2019] [Accepted: 04/24/2019] [Indexed: 01/04/2023] Open
Abstract
Candida albicans is the main causative pathogen of denture stomatitis, which affects many complete denture patients. Objective: To evaluate the effect of different concentrations of nanodiamonds (NDs) added to polymethyl methacrylate (PMMA) denture base material on Candida albicans adhesion as well as on surface roughness and contact angle. Methodology: Acrylic resin specimens sized 10×10×3 mm3 were prepared and divided into four groups (n=30) according to ND concentration (0%, 0.5%, 1%, 1.5% by wt). Surface roughness was measured with a profilometer, and the contact angle with a goniometer. The effect of NDs on Candida albicans adhesion was evaluated using two methods: 1) slide count and 2) direct culture test. Analysis of variance (ANOVA) and Tukey's post hoc test were used in the statistical analyses. Results: Addition of NDs decreased the Candida albicans count significantly more than in the control group (p<0.05), with a lowest of 1% NDs. Addition of NDs also significantly decreased the surface roughness (p<0.05), but the contact angle remained the same. Incorporation of NDs into the PMMA denture base material effectively reduced Candida albicans adhesion and decreased surface roughness. Conclusion: PMMA/NDs composites could be valuable in the prevention of denture stomatitis, which is considered one of the most common clinical problems among removable denture wearers.
Collapse
Affiliation(s)
- Shaimaa M Fouda
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Mohammed M Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Passent Ellakany
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Ahmad M Al-Thobity
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Fahad A Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Jorma I Virtanen
- Department of Community Dentistry, Faculty of Medicine, University of Turku, Turku, Finland.,Medical Research Center Oulu, Oulu University Hospital and University of Oulu, Oulu, Finland
| | - Aune Raustia
- Research Unit of Oral Health Sciences, Prosthetic Dentistry and Stomatognathic Physiology, Faculty of Medicine, University of Oulu, Oulu, Finland.,Medical Research Center Oulu, Oulu University Hospital and University of Oulu, Oulu, Finland
| |
Collapse
|
22
|
Alsrouji MS, Ahmad R, Ibrahim N, Kuntjoro W, Al-Harbi FA, Baba NZ. Blood Flow Alterations in the Anterior Maxillary Mucosa as Induced by Implant-Retained Overdenture. J Prosthodont 2019; 28:373-378. [PMID: 30875139 DOI: 10.1111/jopr.13047] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/05/2019] [Indexed: 11/28/2022] Open
Abstract
PURPOSE Blood flow disturbance from functional pressure may lead to ischemia and accumulation of metabolites leading to residual ridge resorption (RRR) underneath complete dentures. The purposes of this study were to determine the effect of mandibular complete denture (CD) and implant-retained overdenture (IRO) on blood flow disturbance in the opposing denture bearing-mucosa of maxillary CD and to compare the blood flow disturbance to RRR of the anterior maxilla. MATERIALS AND METHODS The test group included 9 participants rehabilitated by maxillary CD opposing mandibular IRO, while the control group consisted of 4 participants with CDs. Blood flow was measured by laser Doppler flowmetry (LDF) after denture removal for 0, 30, 60, and 90 minutes. RRR was quantified as reduction in bone volume a year post-treatment. The measurement of blood flow was then compared to the quantification of RRR. RESULTS The mean blood flow measure for the IRO group was significantly lower than CD after immediate denture removal and 30 minutes later. After 60 minutes, the mean difference was not significant between groups, and at 90 minutes, the mean blood flow of both groups equalized to reach a steady state of 377 BPU. The mandibular IRO had reduced the initial blood flow measure in the opposing anterior maxilla mucosa to almost a quarter (103 BPU) of the steady state value (377 BPU) compared to the CD, which reduced it to only about one half (183 BPU), suggesting greater blood flow disturbance in the IRO group. This result is in tandem with the greater reduction of bone volume observed in the IRO group, which was 7.3 ± 1.3% after a year, almost three times higher than CD group at 2.6 ± 1.7%. CONCLUSION IRO may cause significantly higher blood flow disturbance than CD and may have contributed to greater RRR in the anterior maxilla.
Collapse
Affiliation(s)
- Mohamed Samih Alsrouji
- Center of Restorative Dentistry Studies, Universiti Teknologi MARA, Sg Buloh Campus, Selangor, Malaysia
| | - Rohana Ahmad
- Center of Restorative Dentistry Studies, Universiti Teknologi MARA, Sg Buloh Campus, Selangor, Malaysia.,Integrative Pharmacogenomics Institute, Puncak Alam, Selangor, Malaysia
| | - Norliza Ibrahim
- Department of Oro-Maxillofacial and Medical Sciences, Faculty of Dentistry, University of Malaya, Kuala Lumpur, Malaysia
| | - Wahyu Kuntjoro
- Faculty of Mechanical Engineering, Universiti Teknologi MARA, Selangor, Malaysia
| | - Fahad A Al-Harbi
- Department of Substitutive Dental Sciences, Immam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Nadim Z Baba
- Advanced Education Program in Prosthodontics, Loma Linda University, School of Dentistry, Loma Linda, CA
| |
Collapse
|
23
|
Al-Harbi FA, Abdel-Halim MS, Gad MM, Fouda SM, Baba NZ, AlRumaih HS, Akhtar S. Effect of Nanodiamond Addition on Flexural Strength, Impact Strength, and Surface Roughness of PMMA Denture Base. J Prosthodont 2018; 28:e417-e425. [PMID: 30353608 DOI: 10.1111/jopr.12969] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/19/2018] [Indexed: 11/27/2022] Open
Abstract
PURPOSE To assess the effect of addition of different concentrations of nanodiamonds (NDs) on flexural strength, impact strength, and surface roughness of heat-polymerized acrylic resin. MATERIALS AND METHODS 120 specimens were fabricated from heat-polymerized acrylic resin. They were divided into a control group of pure polymethylmethacrylate (PMMA; Major.Base.20) and three tested groups (PMMA-ND) with 0.5%wt, 1%wt, and 1.5%wt of added ND to PMMA. Flexural strength was determined using the three-point bending test. Impact strength was recorded by using a Charpy type impact test. Surface roughness test was performed using a Contour GT machine. One-way ANOVA and Tukey's post-hoc analysis (p ≤ 0.05) were used for statistical analysis. RESULTS Acrylic resin reinforced with 0.5% ND displayed significantly higher flexural strength than the unreinforced heat-polymerized specimens, acrylic resin reinforced with 1% ND and the 1.5% ND (p < 0.0001). The impact strength of unreinforced heat-polymerized specimens was significantly higher than all nano-composite materials (p < 0.0001) with no significant difference between 1% ND and the 1.5% ND (p > 0.05). The addition of 0.5% ND and 1% ND significantly decreased the surface roughness in comparison to both control and the 1.5% ND groups (p < 0.0001) while no significant differences between 0.5% ND and 1% ND (p > 0.05) were reported. Nano-composite material (0.5% ND) showed significantly lower surface roughness when compared to other specimens. CONCLUSIONS The addition of NDs to acrylic denture base improved the flexural strength and surface roughness at low concentrations (0.5%), while the impact strength was decreased with ND addition.
Collapse
Affiliation(s)
- Fahad A Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Mohamed S Abdel-Halim
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Mohammed M Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Shaimaa M Fouda
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Nadim Z Baba
- Advanced Education Program in Prosthodontics, Loma Linda University School of Dentistry, Loma Linda, CA
| | - Hamad S AlRumaih
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Sultan Akhtar
- Department of Biophysics, Institute for Research and Medical Consultations, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| |
Collapse
|
24
|
Mina NR, Baba NZ, Al-Harbi FA, Elgezawi MF, Daou M. The influence of simulated aging on the color stability of composite resin cements. J Prosthet Dent 2018; 121:306-310. [PMID: 30139678 DOI: 10.1016/j.prosdent.2018.03.014] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2018] [Accepted: 03/13/2018] [Indexed: 10/28/2022]
Abstract
STATEMENT OF PROBLEM Data for the color stability of dual-polymerized and light-polymerized resin cements used in esthetic dentistry are lacking. PURPOSE The purpose of this in vitro study was to evaluate the color stability of 4 types of composite resin cements after water aging. MATERIAL AND METHODS Specimens (n=30) of each resin cement (Variolink Esthetic LC, RelyX Ultimate DC, Nexus 3 DC, Nexus 3 LC) were prepared. The shade selected was Light+ for Variolink Esthetic, B 0.5 for RelyX Ultimate, and White for both Nexus 3 DC and LC. All 120 specimens were aged by water for 30 days at 37°C under dark conditions, using a thermocycling machine. The specimens' color characteristics (L*, luminosity; a*, red-green; b*, yellow-blue) and color differences (ΔE) were measured with a spectrophotometer before day 0, after day 1, and after 30 days of immersion. Statistical analysis used ANOVA and Tukey post hoc tests (α=.05). RESULTS Considering ΔE<3.3 as clinically acceptable, results showed significant color variations for all cements (RelyX Ultimate=3.69; Nexus 3 LC=3.76; Nexus 3 DC=5.34), except for Variolink Esthetic (0.88). However, this variation was significantly less when day 1 was considered the baseline measurement, showing clinically acceptable ΔE values for all types of cement. CONCLUSIONS Water aging had a significant effect on color stability; most color variations occurred in the first 24 hours of polymerization, with relatively nonsignificant variations afterwards.
Collapse
Affiliation(s)
- Nijad R Mina
- Private practice, Magrabi Hospital, Al-Khobar, Saudi Arabia
| | - Nadim Z Baba
- Professor, Advanced Specialty Education Program in Prosthodontics, Loma Linda School of Dentistry, Loma Linda, Calif.
| | - Fahad A Al-Harbi
- Professor and Dean, Department of Substitutive Dental Sciences, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Moataz F Elgezawi
- Professor, Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Maha Daou
- Director of Research, Department of Biomaterials, Saint Joseph University, Beirut, Lebanon
| |
Collapse
|
25
|
Baba NZ, Al-Harbi FA, AlRumaih HS, AlShehri A. A Novel Extended Range Attachment System to Retain Implant Overdentures: A Clinical Report. J Prosthodont 2018; 28:3-9. [PMID: 29855111 DOI: 10.1111/jopr.12907] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/05/2018] [Indexed: 11/28/2022] Open
Abstract
Various attachment systems have been used to facilitate the retention, stability, and support of overdentures. The low profile design, pivoting technology, and durability of the Locator attachment made it one of the commonly used tissue-supported implant-retained overdentures. It has been successfully used to retain overdentures as well as partial dentures. This article describes the uses of the new Locator R-Tx abutment and illustrates both the direct and indirect techniques used to process the denture attachment housing into the prosthesis to retain overdentures and partial dentures.
Collapse
Affiliation(s)
- Nadim Z Baba
- Advanced Specialty Education Program in Prosthodontics Loma Linda School of Dentistry, Loma Linda, CA
| | - Fahad A Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Hamad S AlRumaih
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | | |
Collapse
|
26
|
Abstract
Implant-supported overdentures are becoming the treatment of choice for the completely edentulous mandible. They significantly improve the quality of life in edentulous patients. For this review article, the literature was searched to identify pertinent studies. No meta-analysis was conducted because of high heterogeneity within the literature. Accordingly, in this review article, the author provides an update on implant-supported mandible overdentures with regard to the number of implants, type of loading, stress-strain distribution, mode of implant-to-denture attachment, occlusal considerations and complications.
Collapse
Affiliation(s)
- Fahad A Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| |
Collapse
|
27
|
ArRejaie A, Alalawi H, Al-Harbi FA, Abualsaud R, Al-Thobity AM. Internal Fit and Marginal Gap Evaluation of Zirconia Copings Using Microcomputed Tomography: An In Vitro Analysis. INT J PERIODONT REST 2017; 38:857–863. [PMID: 29077775 DOI: 10.11607/prd.2869] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The purpose of this in vitro study was to measure the marginal and internal fit of single-unit all-ceramic zirconia copings (ZCs) fabricated through three different computer-aided design/computer-assisted manufacture (CAD/CAM) systems using microcomputed tomography (microCT). A total of 10 ZCs were produced for each experimental group. Scanning of the stainless steel (SS) model with its respective copings was conducted with a SkyScan machine. DataViewer software was used to acquire cross-sectional images. Locations of cross-sections for all specimens were standardized to reduce errors. Seven different cross-section locations were selected: four transverse and three sagittal. Adobe Photoshop CS3 was used for the measurements. One-way analysis of variance and Tukey post hoc test were used for the statistical analysis for each group. In addition, t test (α = .05) was used to compare values at each measurement location for the different groups. The results of this study show significant differences in the precision of fit of the experimental groups at the axio-occlusal transition (AOT) location, with a significant gap present in the DeguDent CAD/CAM System compared to the other two systems. Tukey test results indicate a significant difference in the marginal gap between the DeguDent CAD/CAM System and KaVo Everest Dental CAD/CAM System (P = .004). In addition, there is a significant difference in gap size values in the sagittal sections distal to the midline between the DeguDent CAD/CAM System and the Lava Ultimate CAD/CAM System (P = .002). The different CAD/CAM systems showed a clinically acceptable internal fit and marginal adaptation. Different levels of fit were found between the experimental groups. Marginal adaptation was the best in all experimental groups. The gap at the AOT area varied among the three groups, with the DeguDent CAD/CAM System showing the greatest value.
Collapse
|
28
|
Gad MM, Fouda SM, Al-Harbi FA, Näpänkangas R, Raustia A. PMMA denture base material enhancement: a review of fiber, filler, and nanofiller addition. Int J Nanomedicine 2017; 12:3801-3812. [PMID: 28553115 PMCID: PMC5440038 DOI: 10.2147/ijn.s130722] [Citation(s) in RCA: 154] [Impact Index Per Article: 22.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
This paper reviews acrylic denture base resin enhancement during the past few decades. Specific attention is given to the effect of fiber, filler, and nanofiller addition on poly(methyl methacrylate) (PMMA) properties. The review is based on scientific reviews, papers, and abstracts, as well as studies concerning the effect of additives, fibers, fillers, and reinforcement materials on PMMA, published between 1974 and 2016. Many studies have reported improvement of PMMA denture base material with the addition of fillers, fibers, nanofiller, and hybrid reinforcement. However, most of the studies were limited to in vitro investigations without bioactivity and clinical implications. Considering the findings of the review, there is no ideal denture base material, but the properties of PMMA could be improved with some modifications, especially with silanized nanoparticle addition and a hybrid reinforcement system.
Collapse
Affiliation(s)
- Mohammed M Gad
- Department of Substitutive Dental Sciences, College of Dentistry, University of Dammam, Dammam, Kingdom of Saudi Arabia
| | - Shaimaa M Fouda
- Department of Substitutive Dental Sciences, College of Dentistry, University of Dammam, Dammam, Kingdom of Saudi Arabia.,Research Unit of Oral Health Sciences, Faculty of Medicine, University of Oulu, Oulu, Finland
| | - Fahad A Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, University of Dammam, Dammam, Kingdom of Saudi Arabia
| | - Ritva Näpänkangas
- Research Unit of Oral Health Sciences, Faculty of Medicine, University of Oulu, Oulu, Finland.,Medical Research Center, Oulu, Oulu University Hospital and University of Oulu, Oulu, Finland
| | - Aune Raustia
- Research Unit of Oral Health Sciences, Faculty of Medicine, University of Oulu, Oulu, Finland.,Medical Research Center, Oulu, Oulu University Hospital and University of Oulu, Oulu, Finland
| |
Collapse
|
29
|
AlHumaid J, Tantawi ME, Al-Ansari AA, Al-Harbi FA. Agreement in Scoring Preclinical Dental Procedures: Impact on Grades and Instructor-Related Determinants. J Dent Educ 2016; 80:553-562. [PMID: 27139206] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2015] [Accepted: 11/17/2015] [Indexed: 06/05/2023]
Abstract
The aims of this study were to assess agreement among instructors in scoring preclinical dental procedures, the effect of this agreement on grades, and factors associated with agreement and grades differences. Twenty-six instructors from five clinical specialties participated in a scoring exercise at the College of Dentistry, University of Dammam, Saudi Arabia, in January 2015. Instructors blindly and independently scored 19-20 anonymous students' procedures, filling forms with rating scales as used in preclinical lab sessions. Their scores were compared to those of gold standard instructors in the same specialty. Percent agreement and having one letter grade difference from gold standard instructors were assessed, and associated factors were investigated after controlling for the effect of specialty/student. Agreement between instructors and their specialty gold standards occurred in 54.3% of decisions, with only 12.8% similar scores and 52.8% of scores representing underestimation in relation to gold standards. Instructor-related variables accounted for 40-50% of the variation in percent score as well as percent agreement and percent difference between instructors and gold standards. Educational background and teaching experience were significantly associated with less agreement among instructors and odds of one letter grade difference. Modest agreement existed among instructors in scoring various preclinical procedures, and there was a considerable percentage of one letter grade difference from gold standard instructors. Some factors associated with these outcomes are non-modifiable, but corrective measures are needed to increase agreement in scoring among instructors.
Collapse
Affiliation(s)
- Jehan AlHumaid
- Dr. AlHumaid is Assistant Professor, Department of Preventive Dental Sciences, College of Dentistry, University of Dammam, Saudi Arabia; Dr. El Tantawi is Associate Professor, Department of Preventive Dental Sciences, College of Dentistry, University of Dammam, Saudi Arabia; Dr. Al-Ansari is Associate Professor, Department of Preventive Dental Sciences, College of Dentistry, University of Dammam, Saudi Arabia; and Dr. Al-Harbi is Associate Professor, Department of Substitutive Dental Sciences, College of Dentistry, University of Dammam, Saudi Arabia
| | - Maha El Tantawi
- Dr. AlHumaid is Assistant Professor, Department of Preventive Dental Sciences, College of Dentistry, University of Dammam, Saudi Arabia; Dr. El Tantawi is Associate Professor, Department of Preventive Dental Sciences, College of Dentistry, University of Dammam, Saudi Arabia; Dr. Al-Ansari is Associate Professor, Department of Preventive Dental Sciences, College of Dentistry, University of Dammam, Saudi Arabia; and Dr. Al-Harbi is Associate Professor, Department of Substitutive Dental Sciences, College of Dentistry, University of Dammam, Saudi Arabia.
| | - Asim A Al-Ansari
- Dr. AlHumaid is Assistant Professor, Department of Preventive Dental Sciences, College of Dentistry, University of Dammam, Saudi Arabia; Dr. El Tantawi is Associate Professor, Department of Preventive Dental Sciences, College of Dentistry, University of Dammam, Saudi Arabia; Dr. Al-Ansari is Associate Professor, Department of Preventive Dental Sciences, College of Dentistry, University of Dammam, Saudi Arabia; and Dr. Al-Harbi is Associate Professor, Department of Substitutive Dental Sciences, College of Dentistry, University of Dammam, Saudi Arabia
| | - Fahad A Al-Harbi
- Dr. AlHumaid is Assistant Professor, Department of Preventive Dental Sciences, College of Dentistry, University of Dammam, Saudi Arabia; Dr. El Tantawi is Associate Professor, Department of Preventive Dental Sciences, College of Dentistry, University of Dammam, Saudi Arabia; Dr. Al-Ansari is Associate Professor, Department of Preventive Dental Sciences, College of Dentistry, University of Dammam, Saudi Arabia; and Dr. Al-Harbi is Associate Professor, Department of Substitutive Dental Sciences, College of Dentistry, University of Dammam, Saudi Arabia
| |
Collapse
|
30
|
Affiliation(s)
- Jehan AlHumaid
- Department of Preventive Dental Sciences; College of Dentistry; University of Dammam; Saudi Arabia
| | - Maha El Tantawi
- Department of Preventive Dental Sciences; College of Dentistry; University of Dammam; Saudi Arabia
| | - Asim A. Al-Ansari
- Department of Preventive Dental Sciences; College of Dentistry; University of Dammam; Saudi Arabia
| | - Fahad A. Al-Harbi
- Department of Substitutive Dental Sciences; College of Dentistry; University of Dammam; Saudi Arabia
| |
Collapse
|
31
|
Al-Harbi FA, Ayad NM, Khan ZA, Mahrous AA, Morgano SM. In vitro shear bond strength of Y-TZP ceramics to different core materials with the use of three primer/resin cement systems. J Prosthet Dent 2016; 115:84-9. [PMID: 26412003 DOI: 10.1016/j.prosdent.2015.07.002] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2014] [Revised: 07/07/2015] [Accepted: 07/14/2015] [Indexed: 11/19/2022]
Affiliation(s)
- Fahad A Al-Harbi
- Associate Professor, Substitutive Dental Sciences Department, University of Dammam, Dammam, Saudi Arabia
| | - Neveen M Ayad
- Associate Professor, Restorative Dental Sciences Department, University of Dammam, Dammam, Saudi Arabia; and Assistant Professor, Dental Biomaterials Department, Mansoura University, Mansoura, Egypt
| | - Zahid A Khan
- Lecturer, Substitutive Dental Sciences Department, University of Dammam, Dammam, Saudi Arabia
| | - Amr A Mahrous
- Professor, Substitutive Dental Sciences Department, University of Dammam, Dammam, Saudi Arabia
| | - Steven M Morgano
- Professor, Rutgers School of Dental Medicine, Rutgers University, Newark, NJ.
| |
Collapse
|
32
|
Al-Harbi FA, Ayad NM, ArRejaie AS, Bahgat HA, Baba NZ. Effect of Aging Regimens on Resin Nanoceramic Chairside CAD/CAM Material. J Prosthodont 2015; 26:432-439. [DOI: 10.1111/jopr.12408] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/12/2015] [Indexed: 12/01/2022] Open
Affiliation(s)
- Fahad A. Al-Harbi
- Associate Professor and Chairman of Substitutive Dental Sciences Department, College of Dentistry; University of Dammam; Kingdom of Saudi Arabia
| | - Neveen M. Ayad
- Associate Professor, Restorative Dental Sciences Department, College of Dentistry, University of Dammam, Kingdom of Saudi Arabia, Assistant Professor, Dental Biomaterials Department, Faculty of Dentistry; Mansoura University; Egypt
| | - Aws S. ArRejaie
- Assistant Professor, Substitutive Dental Sciences Department; University of Dammam; Dammam City Kingdom of Saudi Arabia
| | - Hala A. Bahgat
- Professor, Restorative Dental Sciences Department, College of Dentistry, University of Dammam, Kingdom of Saudi Arabia, Professor, Dental Biomaterials Department, Faculty of Dentistry; Cairo University; Egypt
| | - Nadim Z. Baba
- Professor and Director, Hugh Love Center for Research and Education in Technnology; Loma Linda School of Dentistry; CA
| |
Collapse
|
33
|
Al-Harbi FA, Ayad NM, Saber MA, ArRejaie AS, Morgano SM. Mechanical behavior and color change of facial prosthetic elastomers after outdoor weathering in a hot and humid climate. J Prosthet Dent 2015; 113:146-51. [DOI: 10.1016/j.prosdent.2014.09.008] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2014] [Revised: 09/24/2014] [Accepted: 09/24/2014] [Indexed: 11/25/2022]
|