1
|
Inoue T, Ibusuki M, Kitano R, Ito K. Endoscopic ultrasound-guided choledochoduodenostomy using a novel, ultra-stiff, high-sliding guidewire and a dumbbell-shaped metal stent. Endoscopy 2024; 56:E140-E141. [PMID: 38359881 PMCID: PMC10869224 DOI: 10.1055/a-2241-2030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/17/2024]
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, Nagakute, Japan
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, Nagakute, Japan
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, Nagakute, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, Nagakute, Japan
| |
Collapse
|
2
|
Inoue T, Ibusuki M, Kitano R, Kobayashi Y, Ito K, Yoneda M. Successful hemostasis and subsequent cannulation using a self-assembling peptide hydrogel for bleeding after precut sphincterotomy. Endoscopy 2023; 55:E759-E760. [PMID: 37236256 PMCID: PMC10219753 DOI: 10.1055/a-2085-0838] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| |
Collapse
|
3
|
Inoue T, Ibusuki M, Kitano R, Ito K. Long-term disease control by endobiliary radiofrequency ablation in localized extrahepatic cholangiocarcinoma: a first case report. Clin J Gastroenterol 2023; 16:908-912. [PMID: 37615832 DOI: 10.1007/s12328-023-01845-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/18/2023] [Accepted: 08/08/2023] [Indexed: 08/25/2023]
Abstract
An 84-year-old woman with cerebrovascular disease, dementia, and chronic kidney disease developed jaundice because of localized extrahepatic cholangiocarcinoma (eCCA) at the lower bile duct. Aggressive treatment, including surgery and chemotherapy, was difficult because of the underlying disease; therefore, only metal stent placement with endobiliary radiofrequency ablation (RFA) was performed. Subsequently, six additional RFA sessions were performed 12, 16, 24, 27, 33, and 36 months after the initial RFA using the same settings as the first RFA session. All these procedures were performed for tumor ingrowth. Computed tomography performed 42 months after the initial procedure revealed no stent with stricture resolution and no other metastatic lesion. Thereafter, no recurrence or adverse events have been observed with persisting stent-free status until the reporting of this study (72 months after the initial procedure). This is the first report of a stent-free status and long-term survival in a patient with localized eCCA that was achieved using only endobiliary RFA without any other anti-tumor treatment. Although several problems and issues associated with endobiliary RFA remain unelucidated, it may be a useful therapeutic option for early and localized eCCA in poor surgical candidates.
Collapse
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan.
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| |
Collapse
|
4
|
Inoue T, Ibusuki M, Kitano R, Kobayashi Y, Ito K, Yoneda M. Successful hemostasis using a self-assembling peptide hydrogel for bleeding after endoscopic papillary large-balloon dilation. Endoscopy 2023; 55:E555-E556. [PMID: 36931307 PMCID: PMC10023252 DOI: 10.1055/a-2037-5913] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/19/2023]
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| |
Collapse
|
5
|
Inoue T, Kitano R, Ibusuki M, Kobayashi Y, Ito K, Yoneda M. A novel ultrathin cholangioscope for endoscopic ultrasound-guided antegrade intervention in patients with Roux-en-Y hepaticojejunostomy. Endoscopy 2023; 55:E953-E954. [PMID: 37604436 PMCID: PMC10442198 DOI: 10.1055/a-2127-4957] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 08/23/2023]
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, Nagakute, Japan
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, Nagakute, Japan
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, Nagakute, Japan
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, Nagakute, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, Nagakute, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, Nagakute, Japan
| |
Collapse
|
6
|
Inoue T, Ibusuki M, Kitano R, Ito K. A novel dedicated nonslip short-length balloon catheter for treating hepaticojejunostomy anastomotic stricture in balloon enteroscopy-assisted ERCP. Endoscopy 2023; 55:E1266-E1267. [PMID: 38128589 PMCID: PMC10736106 DOI: 10.1055/a-2218-3193] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/23/2023]
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, Nagakute, Japan
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, Nagakute, Japan
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, Nagakute, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, Nagakute, Japan
| |
Collapse
|
7
|
Inoue T, Kitano R, Ibusuki M, Sakamoto K, Kimoto S, Kobayashi Y, Sumida Y, Nakade Y, Ito K, Yoneda M. Endoscopic Ultrasound-Guided Naso-gallbladder Drainage Using a Dedicated Catheter for Acute Cholecystitis After Transpapillary Metal Stent Placement for Malignant Biliary Obstruction. Dig Dis Sci 2023; 68:4449-4455. [PMID: 37831399 DOI: 10.1007/s10620-023-08135-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Accepted: 09/27/2023] [Indexed: 10/14/2023]
Abstract
BACKGROUND Acute cholecystitis is a significant adverse event after self-expandable metal stent (SEMS) placement for malignant biliary obstruction (MBO); however, no appropriate treatment strategy has been established for its management. AIMS This study aimed to examine the feasibility and utility of endoscopic ultrasound-guided naso-gallbladder drainage (EUS-NGBD) for the management of acute cholecystitis occurring after SEMS placement. METHODS This retrospective study investigated consecutive patients with acute cholecystitis after SEMS placement for unresectable MBO, in whom EUS-NGBD was attempted. The study outcomes included technical success, clinical success, procedure time, adverse event, and cholecystitis recurrence, associated with the procedure. RESULTS During the study period, EUS-NGBD was performed for SEMS-related acute cholecystitis in 30 patients with MBO. The technical and clinical success rates were 96.7% (29/30) and 96.6% (28/29), respectively. The median procedure time was 15 min, and rate of procedure-related adverse event was 3.3% (1/30). The median duration from the procedure to tube removal was 9 days. No adverse events were observed after removal. The median hospitalization duration after the procedure was 14 days, and the median duration to the (re-)start of chemotherapy from cholecystitis onset was 13 days. The median overall survival after EUS-NGBD was 123 days, and the rate of cholecystitis recurrence until death was 4.2% (1/28). CONCLUSIONS This study demonstrated that EUS-NGBD possesses good technical and clinical feasibility with an acceptable adverse event rates and short hospitalization and chemotherapy withdrawal period. Therefore, EUS-NGBD may be a good option for the treatment of SEMS-related cholecystitis in patients with MBO.
Collapse
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan.
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Kazumasa Sakamoto
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Satoshi Kimoto
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Yoshio Sumida
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Yukiomi Nakade
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| |
Collapse
|
8
|
Inoue T, Kitano R, Ibusuki M, Kobayashi Y, Ito K, Yoneda M. Endoscopic gallbladder inside-stenting combined with aspirated lavage for calculous cholecystitis in poor surgical candidates: a prospective pilot study. Sci Rep 2023; 13:21156. [PMID: 38036684 PMCID: PMC10689747 DOI: 10.1038/s41598-023-48543-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Accepted: 11/28/2023] [Indexed: 12/02/2023] Open
Abstract
Although long-term stent placement via endoscopic gallbladder stenting (EGBS) reportedly reduces cholecystitis recurrence in patients unfit to undergo cholecystectomy, it can increase the frequency of other late adverse events (AEs) such as cholangitis. This study aimed to examine the feasibility of endoscopic gallbladder inside-stenting (EGB-IS) with lavage and aspiration. This prospective, single-center, pilot study enrolled 83 patients with acute calculous cholecystitis who were poor candidates for surgery. A dedicated catheter with eight side holes was used for lavage and aspiration, and a dedicated single-pigtail stent equipped with a thread was used for EGB-IS. Outcomes such as technical success, clinical success, early AEs, recurrence of cholecystitis, and other symptomatic late AEs associated with EGB-IS with lavage and aspiration were evaluated. The technical and clinical success rates were 80.7% (67/83) and 98.5% (66/67), respectively. The rate of early AEs was 3.6% (3/83). The rate of recurrent cholecystitis was 4.5% (3/66) and that of symptomatic late AEs (besides cholecystitis) was 6.1% (4/66). Consequently, the rate of overall late AEs (cholecystitis plus other events) was 10.6% (7/66). The 1-, 2-, and 3-year cumulative incidence rates of all late AEs were 3.2%, 11.2%, and 18.9%, respectively. EGB-IS with lavage and aspiration for calculous cholecystitis showed promising results in poor surgical candidates. EGB-IS may be useful when EGBS with long-term stent placement is planned, since prevention of cholecystitis recurrence, without a rise in the incidence of other AEs, is anticipated.
Collapse
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan.
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| |
Collapse
|
9
|
Inoue T, Ibusuki M, Kitano R, Sakamoto K, Kimoto S, Kobayashi Y, Sumida Y, Nakade Y, Ito K, Yoneda M. Comparison of the mechanical properties of retrieval basket catheters for bile duct stones: An experimental study. Indian J Gastroenterol 2023; 42:651-657. [PMID: 37410310 DOI: 10.1007/s12664-023-01396-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Accepted: 05/12/2023] [Indexed: 07/07/2023]
Abstract
BACKGROUND Although numerous retrieval baskets are currently available for the extraction of bile duct stones, their mechanical properties have not been evaluated. This study aimed to ascertain the characteristics of retrieval baskets for bile duct stones by examining their mechanical properties. METHODS This experimental study tested the mechanical properties of seven retrieval baskets for bile duct stones. The radial force (RF) was measured using a dedicated measurement device and the axial force (AF) was measured using the conventional manual method. RESULTS The mean RF differed significantly among the baskets (p < 0.001) and was the strongest for VorticCatch (1.62 N ± 0.02) and COAXIS (1.62 N ± 0.04), followed by RASEN (1.27 N ± 0.02), Memory Basket (0.95 N ± 0.01), 8-wire Nitinol Basket (0.93 N ± 0.01), StoneHunter (0.78 N ± 0.01) and Flower Basket (0.37 N ± 0.01), respectively. The mean AF differed significantly among the baskets (p < 0.001) and was the highest for VorticCatch (0.668 N ± 0.032), followed by COAXIS (0.629 N ± 0.041), StoneHunter (0.574 N ± 0.037), 8-wire Nitinol Basket (0.546 N ± 0.010), Memory Basket (0.542 N ± 0.024), RASEN (0.435 N ± 0.008) and Flower Basket (0.297 N ± 0.011), respectively. The baskets were categorized into four groups with comparable mechanical properties based on the RF and AF: group 1, low RF and low AF; group 2, moderate RF and moderate AF; group 3, high RF and moderate AF; and group 4, high RF and high AF. CONCLUSIONS This study revealed distinct mechanical properties of various retrieval baskets used for extracting bile duct stones, which may enhance the understanding of their action. Our results could also aid the development of retrieval baskets in future.
Collapse
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan.
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Kazumasa Sakamoto
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Satoshi Kimoto
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Yoshio Sumida
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Yukiomi Nakade
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| |
Collapse
|
10
|
Inoue T, Ibusuki M, Kutsumi H. A Novel Cholangioscopy with a 2.0 mm Large Working Channel for Biliary Targeted Biopsy. J Gastrointestin Liver Dis 2023; 32:289. [PMID: 37774219 DOI: 10.15403/jgld-4919] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/19/2023] [Accepted: 05/04/2023] [Indexed: 10/01/2023]
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, Japan.
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi.
| | - Hiromu Kutsumi
- Center for Clinical Research and Advance Medicine, Shiga University of Medical Science, Seta Tsukinowa-cho, Otsu, Shiga, Japan.
| |
Collapse
|
11
|
Inoue T, Ibusuki M, Kutsumi H. A Novel Non-slip Banded Balloon Catheter for Endoscopic Papillary Balloon Dilation. J Gastrointestin Liver Dis 2023; 32:142. [PMID: 37345604 DOI: 10.15403/jgld-4854] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/11/2023] [Accepted: 02/19/2023] [Indexed: 06/23/2023]
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, Japan.
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, Japan.
| | - Hiromu Kutsumi
- Center for Clinical Research and Advance Medicine, Shiga University of Medical Science, Seta Tsukinowa-cho, Otsu, Shiga, Japan.
| |
Collapse
|
12
|
Inoue T, Ibusuki M, Yoneda M. A novel controllable cannula with a short flexible tip for reintervention after stent-by-stent placement in malignant hilar biliary obstruction. J Gastrointestin Liver Dis 2023; 32:120-121. [PMID: 37004231 DOI: 10.15403/jgld-4769] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/11/2022] [Accepted: 12/27/2022] [Indexed: 04/03/2023]
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, Japan.
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, Japan.
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, Japan.
| |
Collapse
|
13
|
Inoue T, Kutsumi H, Ibusuki M, Yoneda M. A novel non-slip banded balloon catheter for endoscopic sphincteroplasty: an ex vivo and in vivo pilot study. Sci Rep 2023; 13:4032. [PMID: 36899107 PMCID: PMC10006090 DOI: 10.1038/s41598-023-31206-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Accepted: 03/08/2023] [Indexed: 03/12/2023] Open
Abstract
Endoscopic balloon sphincteroplasty is an established procedure for the extraction of bile duct stones. However, the balloon often slips during the inflation process, and its length is an impediment if the distance between the papilla and scope is limited and/or the stone is located close to the papilla. This animal experimental study aimed to evaluate the feasibility of a novel short non-slip banded balloon measuring 15-20 mm in length for sphincteroplasty. The ex vivo component of this study was conducted using porcine duodenal papilla. Miniature pigs were subjected to endoscopic retrograde cholangiography in the in vivo component. The technical success of sphincteroplasty without any slippage was the primary outcome of the study and was compared between cases managed with the non-slip banded balloon (non-slip balloon group) and conventional balloon (conventional balloon group). The technical success rate of the ex vivo component, i.e., absence of any slippage, was significantly higher in the non-slip balloon group than in the conventional balloon group with the 8-mm (96.0% vs. 16.0%, P < 0.001) and 12-mm diameter balloons (96.0% vs. 0%, P < 0.001). The technical success rate of endoscopic sphincteroplasty without slippage in the in vivo component was significantly higher in the non-slip balloon group than in the conventional balloon group (100% vs. 40%, P = 0.011). No immediate adverse events were observed in either group. The slippage rate was significantly lower with sphincteroplasty using a non-slip balloon, despite the balloon length being considerably shorter than that of conventional balloons, demonstrating its potential utility in difficult cases.
Collapse
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan.
| | - Hiromu Kutsumi
- Center for Clinical Research and Advance Medicine, Shiga University of Medical Science, Seta Tsukinowa-Cho, Otsu, Shiga, 520-2192, Japan
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| |
Collapse
|
14
|
Inoue T, Ibusuki M, Kutsumi H. Novel non-slip banded balloon catheter for endoscopic papillary balloon dilation in balloon enteroscopy-assisted endoscopic retrograde cholangiopancreatography. Dig Endosc 2023; 35:e33-e34. [PMID: 36504461 DOI: 10.1111/den.14479] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/03/2022] [Accepted: 11/17/2022] [Indexed: 02/08/2023]
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Hiromu Kutsumi
- Center for Clinical Research and Advance Medicine, Shiga University of Medical Science, Shiga, Japan
| |
Collapse
|
15
|
Inoue T, Ibusuki M, Kitano R, Sakamoto K, Kimoto S, Kobayashi Y, Sumida Y, Nakade Y, Ito K, Yoneda M. Double bare metal stent deployment combined with intraductal radiofrequency ablation for malignant distal biliary obstruction: a prospective pilot study. Sci Rep 2023; 13:2654. [PMID: 36788377 PMCID: PMC9929070 DOI: 10.1038/s41598-023-29955-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2022] [Accepted: 02/13/2023] [Indexed: 02/16/2023] Open
Abstract
Although uncovered self-expandable metal stents (SEMSs) possess certain advantages such as averting cystic duct obstruction and stent migration, they are susceptible to ingrowth occlusion. The combination of the double bare stent (DBS) and endobiliary radiofrequency ablation (RFA) may reduce ingrowth. Hence, this study aimed to examine the utility of this method for the treatment of unresectable malignant distal biliary obstruction (MDBO). This prospective, single-center, pilot study enrolled 51 patients who met the eligibility criteria between February 2020 and January 2022. The study outcomes included technical success, clinical success, recurrent biliary obstruction (RBO), and other adverse events (AE) besides RBO associated with DBS placement with RFA for MDBO. The technical success rate was 98.0% (50/51). Clinical success was achieved in all patients in whom technical success was achieved. The rates of early and late AEs were 5.9% (3/51) and 8.0% (4/50), respectively. The incidence rate of RBO was 38.0% (19/50). Sludge occlusion, ingrowth occlusion, and overgrowth occlusion occurred in 26.0% (13/50), 8.0% (4/50), and 2.0% (1/50) of patients, respectively (the main cause of RBO was undeterminable in 1 patient). The median time to RBO was 241 days. DBS with RFA showed good technical feasibility, good long-term outcomes, acceptable AE rates, and most importantly, a low ingrowth occlusion rate when employed for the treatment of MDBO.
Collapse
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan.
| | - Mayu Ibusuki
- grid.411234.10000 0001 0727 1557Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195 Japan
| | - Rena Kitano
- grid.411234.10000 0001 0727 1557Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195 Japan
| | - Kazumasa Sakamoto
- grid.411234.10000 0001 0727 1557Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195 Japan
| | - Satoshi Kimoto
- grid.411234.10000 0001 0727 1557Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195 Japan
| | - Yuji Kobayashi
- grid.411234.10000 0001 0727 1557Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195 Japan
| | - Yoshio Sumida
- grid.411234.10000 0001 0727 1557Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195 Japan
| | - Yukiomi Nakade
- grid.411234.10000 0001 0727 1557Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195 Japan
| | - Kiyoaki Ito
- grid.411234.10000 0001 0727 1557Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195 Japan
| | - Masashi Yoneda
- grid.411234.10000 0001 0727 1557Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195 Japan
| |
Collapse
|
16
|
Inoue T, Ibusuki M, Kitano R, Sakamoto K, Kimoto S, Kobayashi Y, Sumida Y, Nakade Y, Ito K, Yoneda M. Endoscopic radiofrequency ablation for ingrowth occlusion after bilateral metal stent placement for malignant hilar biliary obstruction: a prospective pilot study. Gastrointest Endosc 2023; 97:282-290.e1. [PMID: 36220379 DOI: 10.1016/j.gie.2022.09.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Revised: 09/20/2022] [Accepted: 09/26/2022] [Indexed: 01/28/2023]
Abstract
BACKGROUND AND AIMS Endoscopic biliary radiofrequency ablation (RFA) may be an option for the treatment of ingrowth occlusion after self-expandable metal stent (SEMS) deployment; however, its utility remains uncertain. This study aimed to examine the feasibility of RFA for the palliation of ingrowth after bilateral SEMS placement in patients with malignant hilar biliary obstruction. METHODS This prospective, single-center, pilot study enrolled 30 patients who met the eligibility criteria between April 2020 and March 2022. Study outcomes were technical success, clinical success, recurrent biliary obstruction (RBO), and adverse events (AEs) besides RBO associated with RFA for ingrowth occlusion. Furthermore, factors predictive of clinical success were evaluated. RESULTS Technical and clinical success rates were 93.3% (28/30) and 71.4% (20/28), respectively. The rates of early and late AEs were 6.7% (2/30) and 10.0% (2/20), respectively. The incidence rate of RBO after RFA was 45.0% (9/20), and the median time to RBO was 163 days. Multivariate analysis of the factors affecting clinical success revealed a positive association between the recanalization diameter on the ingrown part within the SEMS (odds ratio, 1.13; 95% confidence interval, 1.01-1.26; P = .038). The calculated optimal cutoff for the ratio of the recanalization diameter to the SEMS diameter for predicting clinical success was 51.1%. CONCLUSIONS Endoscopic biliary RFA elicited promising results, with good long-term stent patency and without the requirement of any additional stent placement, for the palliation of ingrowth occlusion after bilateral SEMS placement. However, the clinical success rate was insufficient, necessitating improvements in the future. (Clinical trial registration number: UMIN000040154.).
Collapse
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Kazumasa Sakamoto
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Satoshi Kimoto
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Yoshio Sumida
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Yukiomi Nakade
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| |
Collapse
|
17
|
Inoue T, Kutsumi H, Ibusuki M, Yoneda M. Endoscopic biliary ethanol ablation using a novel multi-hole balloon catheter: In vivo feasibility study in a swine model. PLoS One 2023; 18:e0283733. [PMID: 37000862 PMCID: PMC10065430 DOI: 10.1371/journal.pone.0283733] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Accepted: 03/15/2023] [Indexed: 04/03/2023] Open
Abstract
BACKGROUND Minimally invasive local treatment could be a good option for the treatment of extrahepatic cholangiocarcinoma (eCCA). This study aimed to evaluate the feasibility of a novel local treatment method, endoscopic biliary ethanol ablation (EA), in vivo using a swine model. METHODS This study utilized a prototype of the newly developed multi-hole balloon catheter. The swine bile duct was ablated using this balloon via the same approach as the conventional endoscopic retrograde cholangiography procedure. The study outcomes included technical success, clinical success, and adverse events associated with endoscopic biliary EA. RESULTS Fourteen miniature pigs underwent endoscopic biliary EA. Technical success was achieved for all endoscopic EA procedures without any hindrance. All pigs were reared and followed up for a median 35-day period after the procedure. No change was observed in the bile duct wall in one case, in which sufficient contact was not achieved between the balloon and bile duct wall. Except for this case, stricture formation occurred at the site of ablation, where the epithelium was sloughed and necrosis with denaturation replaced the granulation tissue and fibrotic changes. The median length and depth of the ablation area were 17.05 and 2.21 mm, respectively. No adverse events were observed, except for the formation of bile duct strictures and sequelae associated with strictures. CONCLUSIONS This preliminary study was the first to report endoscopic biliary EA using a novel multi-hole balloon catheter, which demonstrated technical feasibility and potential for the treatment for eCCA.
Collapse
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, Nagakute, Aichi, Japan
- * E-mail:
| | - Hiromu Kutsumi
- Center for Clinical Research and Advance Medicine, Shiga University of Medical Science, Seta Tsukinowa-cho, Otsu, Shiga, Japan
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, Nagakute, Aichi, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, Nagakute, Aichi, Japan
| |
Collapse
|
18
|
Inoue T, Kutsumi H, Ibusuki M, Yoneda M. Examining the efficacy and safety of endobiliary radiofrequency ablation for ingrowth occlusion after metal stent placement using a bovine model. Int J Hyperthermia 2022; 39:1415-1420. [DOI: 10.1080/02656736.2022.2146212] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, Nagakute, Japan
| | - Hiromu Kutsumi
- Center for Clinical Research and Advance Medicine, Shiga University of Medical Science, Otsu, Japan
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, Nagakute, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, Nagakute, Japan
| |
Collapse
|
19
|
Inoue T, Ibusuki M, Kitano R, Kobayashi Y, Ito K, Yoneda M. A novel controllable catheter with a short flexible tip for guidewire insertion in severe malignant hilar biliary stricture. Endoscopy 2022; 55:E318-E319. [PMID: 36513104 PMCID: PMC9833939 DOI: 10.1055/a-1978-8077] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| |
Collapse
|
20
|
Inoue T, Ibusuki M, Kitano R, Sakamoto K, Kimoto S, Kobayashi Y, Sumida Y, Nakade Y, Ito K, Yoneda M. Comparison of the removal ability of basket catheters for small bile duct stones impacted in the corner pocket of the lower bile duct. Endoscopy 2022; 54:987-992. [PMID: 35144287 DOI: 10.1055/a-1769-0514] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Abstract
BACKGROUND : Endoscopic stone extraction is often challenging in patients with a significant lower bile duct corner pocket, where small stones are likely to escape and become impacted. This study aimed to determine the utility of different types of baskets for retrieving corner pocket stones. METHODS : Seven types of retrieval baskets were evaluated on silicone models. The study outcomes included the characteristics of each basket and technical success rates associated with the retrieval of stones impacted in the corner pocket. RESULTS : The overall success rate was only 27.5 %, with significant differences between the baskets (P < 0.001). Only three baskets yielded successful removal. The success rates were 10 %, 25 %, and 70 % with the 8-wire Nitinol Basket, RASEN, and VorticCatch V, respectively, all of which are helical eight-wire baskets. RASEN and VorticCatch V share similar characteristics, including a strong spiral wire and smaller interwire spaces at their distal ends. The addition of rotation significantly increased the success rate to 80 % with the 8-wire Nitinol Basket (P < 0.001) and 90 % with RASEN (P < 0.001). CONCLUSIONS : Robust helical eight-wire baskets with smaller interwire spaces at the tip may be effective for extracting corner pocket stones, while the addition of rotational motion may improve the efficacy of retrieval.
Collapse
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, Nagakute, Aichi, Japan
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, Nagakute, Aichi, Japan
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, Nagakute, Aichi, Japan
| | - Kazumasa Sakamoto
- Department of Gastroenterology, Aichi Medical University, Nagakute, Aichi, Japan
| | - Satoshi Kimoto
- Department of Gastroenterology, Aichi Medical University, Nagakute, Aichi, Japan
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, Nagakute, Aichi, Japan
| | - Yoshio Sumida
- Department of Gastroenterology, Aichi Medical University, Nagakute, Aichi, Japan
| | - Yukiomi Nakade
- Department of Gastroenterology, Aichi Medical University, Nagakute, Aichi, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, Nagakute, Aichi, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, Nagakute, Aichi, Japan
| |
Collapse
|
21
|
Inoue T, Ibusuki M, Kitano R, Sakamoto K, Kimoto S, Kobayashi Y, Sumida Y, Nakade Y, Ito K, Yoneda M. Novel J-tip guidewire for reintervention after stent-by-stent placement in patients with malignant hilar biliary obstruction. Endosc Int Open 2022; 10:E1291-E1296. [PMID: 36118649 PMCID: PMC9473852 DOI: 10.1055/a-1899-4124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Accepted: 07/12/2022] [Indexed: 11/06/2022] Open
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, Aichi
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, Aichi
| | | | | | - Satoshi Kimoto
- Department of Gastroenterology, Aichi Medical University, Aichi
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, Aichi
| | - Yoshio Sumida
- Department of Gastroenterology, Aichi Medical University, Aichi
| | - Yukiomi Nakade
- Department of Gastroenterology, Aichi Medical University, Aichi
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, Aichi
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, Aichi
| |
Collapse
|
22
|
Inoue T, Ibusuki M, Kitano R, Sakamoto K, Kimoto S, Kobayashi Y, Ohashi T, Sumida Y, Nakade Y, Ito K, Yoneda M. Endobiliary Radiofrequency Ablation Using a Short-Type Balloon Enteroscope in Patients with Surgically Altered Anatomy. Dig Dis Sci 2022; 67:4181-4187. [PMID: 34410572 DOI: 10.1007/s10620-021-07224-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Accepted: 08/10/2021] [Indexed: 12/09/2022]
Abstract
BACKGROUND Endoscopic radiofrequency ablation (RFA) is expected to prolong stent patency for malignant biliary obstruction (MBO). However, its feasibility when used in conjunction with a balloon enteroscope (BE) in patients with surgically altered anatomy (SAA) remains unknown. AIMS This study aimed to investigate the feasibility of RFA combined with metal stent insertion under BE guidance for MBO in patients with SAA. METHODS Thirty-seven patients who underwent treatment between October 2016 and January 2021 and met the eligibility criteria were investigated retrospectively. Study outcomes included technical and clinical success, recurrent biliary obstruction (RBO), and other adverse events besides RBO associated with RFA with metal stent placement using BE. RESULTS Technical and clinical success rates were 100% (37/37) each. The rates of early and late adverse events were 8.1% (3/37) and 8.1% (3/37), respectively. RBO occurred in 32.4% (12/37) of the patients, and the median time to RBO was 296 days. The cause of RBO was ingrowth in eight patients, overgrowth in three patients, and indeterminate in one patient. All reinterventions for RBO were successful using the BE approach; all ingrowths, except one, were recanalized using additional RFA without additional stent placement. The frequency of reintervention-related adverse events was 9.1% (1/11). The median time to RBO after reintervention was 166 days. CONCLUSIONS This study demonstrated the technical safety and feasibility as well as good long-term outcomes of endobiliary RFA combined with metal stent placement under BE guidance. This approach may be a useful option for treating MBO in patients with SAA.
Collapse
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan.
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Kazumasa Sakamoto
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Satoshi Kimoto
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Tomohiko Ohashi
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Yoshio Sumida
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Yukiomi Nakade
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| |
Collapse
|
23
|
Inoue T, Ibusuki M, Kitano R, Kobayashi Y, Ito K, Yoneda M. Combined stent-by-stent and stent-in-stent biliary metal stent deployment using a forward-oblique viewing echoendoscope in surgically altered anatomy. Endosc Int Open 2022; 10:E1020-E1021. [PMID: 35845022 PMCID: PMC9286765 DOI: 10.1055/a-1836-9102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/25/2022] Open
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| |
Collapse
|
24
|
Inoue T, Ibusuki M, Kitano R, Sakamoto K, Kimoto S, Kobayashi Y, Ohashi T, Sumida Y, Nakade Y, Ito K, Yoneda M. Safety and Efficacy of Gemcitabine Plus Nab-Paclitaxel for Metastatic Pancreatic Cancer Patients Undergoing Biliary Stent Placement. Dig Dis Sci 2022; 67:3298-3304. [PMID: 34125338 DOI: 10.1007/s10620-021-07098-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Accepted: 06/03/2021] [Indexed: 01/05/2023]
Abstract
BACKGROUND Gemcitabine plus nab-paclitaxel (GnP) is the first-line chemotherapeutic regimen for metastatic pancreatic cancer (MPC); however, there are concerns regarding its safety in patients undergoing biliary stent placement. This study aimed to examine the tolerability and efficacy of GnP in MPC patients who underwent biliary stent placement. METHODS A total of 105 MPC patients who had received GnP treatment between 2015 and 2020 were included and investigated. The patients were divided into two groups: those undergoing biliary stent placement for symptomatic biliary obstruction (BO) (With-BO group) and those without biliary stent placement (Without-BO group). The best tumor response, overall survival (OS), and adverse events in each group were compared. RESULTS The partial response, stable disease, and progressive disease rates were 22%, 61%, and 14.6% in the With-BO group, and 26.6%, 46.9%, and 21.9% in the Without-BO group, respectively, with no significant differences. The median OS was 12.2 months and 14.6 months in the With-BO and Without-BO groups, respectively (P = 0.483). Grade 3 or higher biliary tract-related events were significantly more common in the With-BO group (41.5%) than in the Without-BO group (1.6%) (P < 0.001), but all events were managed successfully by urgent intervention. The rates of any treatment-related toxicities, including febrile neutropenia, were not significantly different, and there were no chemotherapy-related deaths in either group. CONCLUSIONS GnP can be as tolerable and effective in MPC patients with biliary stents as in those without biliary stents. However, careful management and appropriate reintervention to treat biliary tract-related adverse events are required.
Collapse
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan.
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Kazumasa Sakamoto
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Satoshi Kimoto
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Tomohiko Ohashi
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Yoshio Sumida
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Yukiomi Nakade
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| |
Collapse
|
25
|
Inoue T, Ibusuki M, Yoneda M. Pseudoaneurysm after endoscopic biliary radiofrequency ablation for malignant biliary stricture. J Gastrointestin Liver Dis 2022; 31:161. [PMID: 35694988 DOI: 10.15403/jgld-4354] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Accepted: 04/13/2022] [Indexed: 06/15/2023]
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, Nagakute, Aichi, Japan.
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, Nagakute, Aichi, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, Nagakute, Aichi, Japan
| |
Collapse
|
26
|
Inoue T, Ibusuki M, Kitano R, Kobayashi Y, Ito K, Yoneda M. Combined stent-by-stent and stent-in-stent deployment for malignant hilar biliary obstruction using a novel metal stent with flexible cell and slim delivery. Endosc Int Open 2022; 10:E917-E918. [PMID: 35692906 PMCID: PMC9187410 DOI: 10.1055/a-1793-9775] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| |
Collapse
|
27
|
Inoue T, Ibusuki M, Kitano R, Kobayashi Y, Ito K, Yoneda M. Single-operator metal stent deployment for malignant biliary obstruction using a novel thumbwheel delivery system. Endoscopy 2022; 54:E252-E253. [PMID: 34102675 DOI: 10.1055/a-1499-6512] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| |
Collapse
|
28
|
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| |
Collapse
|
29
|
Inoue T, Ibusuki M, Kitano R, Sakamoto K, Kimoto S, Kobayashi Y, Sumida Y, Nakade Y, Ito K, Yoneda M. Scissor-type knife precut in balloon enteroscopy-assisted ERCP for patients with difficult biliary cannulation and surgically altered anatomy (with video). Gastrointest Endosc 2022; 95:717-722. [PMID: 34762919 DOI: 10.1016/j.gie.2021.10.032] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Accepted: 10/24/2021] [Indexed: 02/08/2023]
Abstract
BACKGROUND AND AIMS Balloon enteroscopy-assisted ERCP (BE-ERCP) is useful for treating pancreatobiliary disease in patients with surgically altered anatomy (SAA); however, biliary cannulation, including the precut technique, is often challenging. This study aimed to examine the feasibility of scissor-type knife precutting (SKP) during BE-ERCP in patients with SAA. METHODS This retrospective study investigated consecutive patients who underwent BE-ERCP and SKP for difficult biliary cannulation between 2016 and 2021. The study outcomes included the technical success and adverse event rates associated with SKP during BE-ERCP. RESULTS During the study period, 125 patients with native duodenal papillae underwent BE-ERCP, and the papilla was reached in 116 patients. The success rate of biliary cannulation with the standard cannulation approach alone was 67.2% (78/116), which increased to 77.6% (90/116) with the inclusion of advanced cannulation techniques besides precutting and further improved to 87.9% (102/116) with the addition of needlife precutting. SKP was attempted in 12 patients in whom all other cannulation approaches were difficult or resulted in failure. The technical success rate of SKP was 66.7% (8/12); thus, SKP increased the final success rate of biliary cannulation to 94.8% (110/116). The rate of adverse events associated with SKP was 8.3% (1/12). CONCLUSIONS This is the first study to report the use of the SKP technique for difficult biliary cannulation in patients with SAA, which may serve as a useful option for salvage cannulation during BE-ERCP.
Collapse
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Kazumasa Sakamoto
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Satoshi Kimoto
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Yoshio Sumida
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Yukiomi Nakade
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| |
Collapse
|
30
|
Inoue T, Naitoh I, Kitano R, Ibusuki M, Kobayashi Y, Sumida Y, Nakade Y, Ito K, Yoneda M. Endobiliary Radiofrequency Ablation Combined with Gemcitabine and Cisplatin in Patients with Unresectable Extrahepatic Cholangiocarcinoma. Curr Oncol 2022; 29:2240-2251. [PMID: 35448156 PMCID: PMC9029596 DOI: 10.3390/curroncol29040182] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Revised: 03/16/2022] [Accepted: 03/19/2022] [Indexed: 12/16/2022] Open
Abstract
Background: Endobiliary radiofrequency ablation (RFA) is a promising treatment modality for patients with extrahepatic cholangiocarcinoma (eCCA). However, no study has investigated the combined use of endobiliary RFA and gemcitabine plus cisplatin (GC) chemotherapy. This study aimed to examine the feasibility and efficacy of endobiliary RFA with GC therapy for patients with unresectable eCCA. Methods: The study outcomes included overall survival (OS), progression-free survival (PFS), time to recurrent biliary obstruction (RBO), and adverse events associated with the treatment. These parameters were retrospectively compared between 25 patients who underwent RFA with self-expandable metal stent (SEMS) placement followed by GC therapy (with-RFA group) and a control cohort of 25 patients who underwent SEMS placement alone and GC therapy (without-RFA group). Results: The median time to RBO was significantly longer in the with-RFA group (10.7 versus 5.2 months, p = 0.048). The median OS was significantly higher in patients with locally advanced tumors in the with-RFA group (23.1 versus 16.6 months, p = 0.032), but did not differ significantly in patients with metastasis (11.4 versus 8.5 months, p = 0.180). Similarly, the median PFS was significantly higher in the with-RFA group in patients with locally advanced disease (10.1 versus 7.3 months, p = 0.015), while there was no significant difference in patients with metastasis (5.4 versus 4.4 months, p = 0.529). The rates of various toxicities did not differ significantly between the groups. Conclusions: Endobiliary RFA prolonged the patency period of uncovered SEMS combined with GC therapy in patients with eCCA. Although RFA also yielded survival benefits, its effect was restricted to locally advanced tumors.
Collapse
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute 480-1195, Japan; (R.K.); (M.I.); (Y.K.); (Y.S.); (Y.N.); (K.I.); (M.Y.)
- Correspondence: ; Tel.: +81-561-62-3311; Fax: +81-561-63-3208
| | - Itaru Naitoh
- Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya 467-8601, Japan;
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute 480-1195, Japan; (R.K.); (M.I.); (Y.K.); (Y.S.); (Y.N.); (K.I.); (M.Y.)
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute 480-1195, Japan; (R.K.); (M.I.); (Y.K.); (Y.S.); (Y.N.); (K.I.); (M.Y.)
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute 480-1195, Japan; (R.K.); (M.I.); (Y.K.); (Y.S.); (Y.N.); (K.I.); (M.Y.)
| | - Yoshio Sumida
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute 480-1195, Japan; (R.K.); (M.I.); (Y.K.); (Y.S.); (Y.N.); (K.I.); (M.Y.)
| | - Yukiomi Nakade
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute 480-1195, Japan; (R.K.); (M.I.); (Y.K.); (Y.S.); (Y.N.); (K.I.); (M.Y.)
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute 480-1195, Japan; (R.K.); (M.I.); (Y.K.); (Y.S.); (Y.N.); (K.I.); (M.Y.)
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute 480-1195, Japan; (R.K.); (M.I.); (Y.K.); (Y.S.); (Y.N.); (K.I.); (M.Y.)
| |
Collapse
|
31
|
Inoue T, Ibusuki M, Kitano R, Kobayashi Y, Ito K, Yoneda M. Novel helical eight-wire basket for retrieving small bile duct stones in the corner pocket of the lower bile duct. Endosc Int Open 2022; 10:E222-E223. [PMID: 35178341 PMCID: PMC8847046 DOI: 10.1055/a-1675-2524] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/03/2022] Open
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, Nagakute, Aichi, Japan
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, Nagakute, Aichi, Japan
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, Nagakute, Aichi, Japan
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, Nagakute, Aichi, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, Nagakute, Aichi, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, Nagakute, Aichi, Japan
| |
Collapse
|
32
|
Inoue T, Kutsumi H, Ibusuki M, Yoneda M. Feasibility of balloon-based endobiliary radiofrequency ablation under cholangioscopy guidance in a swine model. Sci Rep 2021; 11:14254. [PMID: 34244576 PMCID: PMC8270987 DOI: 10.1038/s41598-021-93643-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2021] [Accepted: 06/29/2021] [Indexed: 02/07/2023] Open
Abstract
Although endobiliary radiofrequency ablation (RFA) has demonstrated considerable potential for the treatment of biliary strictures, conventional catheter RFA has several limitations. This study aimed to evaluate the feasibility of a novel cholangioscopy (CS)-guided balloon-based RFA procedure in vivo using a swine model. CS-guided balloon-RFA was performed under endoscopic retrograde cholangiography guidance at target temperatures of 60 ℃ or 70 ℃, which were maintained for 60 s. We evaluated the technical feasibility, adverse events, and histological effects associated with the procedure. Twelve sites were ablated in seven miniature pigs. The CS-guided balloon-RFA procedure was technically successful in all cases without any hindrance. Mucosal changes could be detected during RFA, and the ablation area was identified on CS. Necropsy was performed in four pigs on the same day as the procedure: the tissue samples showed coagulative necrosis, and the entire internal circumference of the bile duct was uniformly ablated. The mean lengths of the ablation area in the samples ablated at 60 °C and 70 °C were 20.64 and 22.18 mm, respectively, while the mean depths were 3.46 and 5.07 mm, respectively. The other three pigs were reared and euthanized and autopsied 35 days after the procedure. The site to be ablated had replaced the granulation tissue and fibrotic changes. No adverse events were observed in any case. CS-guided balloon-RFA appears to be a promising option for treating biliary strictures. This preliminary study could pave the way for the evaluation of this procedure in future human clinical trials.
Collapse
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan.
| | - Hiromu Kutsumi
- Center for Clinical Research and Advance Medicine, Shiga University of Medical Science, Seta Tsukinowa-Cho, Otsu, Shiga, 520-2192, Japan
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| |
Collapse
|
33
|
Inoue T, Kitano R, Ibusuki M, Kobayashi Y, Ito K, Yoneda M. Simultaneous triple stent-by-stent deployment following endobiliary radiofrequency ablation for malignant hilar biliary obstruction. Endoscopy 2021; 53:E162-E163. [PMID: 32818988 DOI: 10.1055/a-1224-3698] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| |
Collapse
|
34
|
Kitano R, Inoue T, Ibusuki M, Kobayashi Y, Ohashi T, Sumida Y, Nakade Y, Ito K, Yoneda M. Safety and Efficacy of Endoscopic Retrograde Cholangiopancreatography in Patients with Performance Status 4. Dig Dis Sci 2021; 66:1291-1296. [PMID: 32440744 DOI: 10.1007/s10620-020-06339-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/05/2020] [Accepted: 05/09/2020] [Indexed: 12/15/2022]
Abstract
BACKGROUND The risk related to endoscopic retrograde cholangiopancreatography (ERCP) in patients with Eastern Cooperative Oncology Group performance status (PS) 4 is uncertain and remains a concern. AIMS We aimed to examine the safety and efficacy of ERCP in patients with PS4 compared to those in patients with PS0-3. METHODS A total of 1845 patients met the eligibility criteria for study inclusion between 2014 and 2018. The patients were divided into two groups: PS0-3 and PS4 groups. The adverse event and therapeutic success rates in each group were compared. Propensity score matching was performed to adjust for differences between the groups. RESULTS The therapeutic success rate was 96% in both groups. The overall adverse event rate was 6% and 10% in the PS0-3 and PS4 groups, respectively, showing no significant difference (P = 0.272). Although the rates of pancreatitis, bleeding, perforation, and cholangitis were equivalent in both groups, the pulmonary adverse event rate was significantly higher in the PS4 group (5% vs. 0.4%; P = 0.006). Severe adverse events were also significantly more frequent in the PS4 group (8% vs. 2%; P = 0.012). Multivariate analyses showed that long procedure time was a significant risk factor for adverse events in patients with PS4 (odds ratio, 10.70; 95% CI 1.30-87.70; P = 0.028). CONCLUSIONS Although ERCP can be performed effectively in patients with PS4, the risk of pulmonary and severe adverse events is high. Prolonged procedures should be avoided in patients with PS4.
Collapse
Affiliation(s)
- Rena Kitano
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan.
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Tomohiko Ohashi
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Yoshio Sumida
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Yukiomi Nakade
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| |
Collapse
|
35
|
Inoue T, Ibusuki M, Kitano R, Kobayashi Y, Ohashi T, Sumida Y, Nakade Y, Ito K, Yoneda M. Radial incision and cutting combined with balloon dilation for refractory pancreaticojejunostomy anastomotic strictures. Endosc Int Open 2021; 9:E578-E582. [PMID: 33860075 PMCID: PMC8041570 DOI: 10.1055/a-1372-3628] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/06/2020] [Accepted: 12/30/2020] [Indexed: 01/10/2023] Open
Abstract
Abstract
Background and study aims Endoscopic balloon dilation (BD) and temporary stent placement for pancreaticojejunostomy anastomotic stricture (PJAS) achieves good short-term outcomes; however, stricture recurrences remain frequent. We examined the feasibility of performing radial incision and cutting (RIC) combined with BD for refractory PJAS.
Patients and methods Five consecutive patients with refractory PJAS who underwent RIC with BD between 2015 and 2018 were retrospectively investigated. We evaluated the technical and clinical success, adverse event (AE), and recurrence rates associated with RIC with BD.
Results In all five patients, technical and clinical success were achieved. Pancreatic stone removal was simultaneously performed in one patient. The mean procedure time was 18 minutes (range 12–23 minutes). There were no procedure-related AEs. All patients were followed for over 2 years, with a mean follow-up period of 33 months (range 24–40 months). During the follow-up period, none of the patients developed stricture recurrence and all anastomoses remained patent.
Conclusions This is the first report of RIC with BD for the treatment of refractory PJAS, showing favorable results. This combined procedure might be a useful option for treating refractory PJAS.
Collapse
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Tomohiko Ohashi
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Yoshio Sumida
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Yukiomi Nakade
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| |
Collapse
|
36
|
Inoue T, Ibusuki M, Kitano R, Kobayashi Y, Ohashi T, Nakade Y, Sumida Y, Ito K, Yoneda M. Early Covered Self-Expandable Metal Stent Placement Is Effective for Massive Post-endoscopic Sphincterotomy Bleeding. Dig Dis Sci 2020; 65:3324-3331. [PMID: 31950313 DOI: 10.1007/s10620-020-06057-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/08/2019] [Accepted: 01/07/2020] [Indexed: 12/09/2022]
Abstract
BACKGROUND Placement of covered self-expandable metallic stent (CSEMS) for post-endoscopic sphincterotomy (ES) bleeding achieves excellent hemostasis results. Although CSEMS placement is typically performed after failure of conventional endoscopic combination therapy, its excellent outcomes may justify earlier placement. AIMS We aimed to examine the efficacy of "early" CSEMS placement for massive post-ES bleeding. METHODS The medical records of 2750 patients who underwent ES between 2005 and 2019 were reviewed retrospectively, and 61 patients who developed massive post-ES bleeding were enrolled. These patients were divided into those who underwent early CSEMS placement (E-CSEMS group) and those who underwent conventional endoscopic combination therapy (Conventional group). The outcomes of hemostasis procedures were compared between the groups. RESULTS The primary success rates of endoscopic hemostasis were 100% (21/21) and 98% (39/40) in the E-CSEMS group and Conventional group, respectively, without significant differences (P = 1.000). However, in the E-CSEMS group, re-bleeding was significantly less frequent (5% vs. 31%; P = 0.023), the median hemostasis procedure time was significantly shorter (14 min vs. 26 min; P < 0.001), and transfusion after initial hemostasis treatment was less commonly required (10% vs. 38%; P = 0.034). Multivariate analyses showed that hemodialysis was associated with a significantly higher re-bleeding rate (P = 0.029), while CSEMS placement was associated with a significantly lower re-bleeding rate (P = 0.039). CONCLUSIONS Early CSEMS placement may be effective for improving the clinical outcomes of massive post-ES bleeding by decreasing re-bleeding and the extent of bleeding.
Collapse
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan.
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Tomohiko Ohashi
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Yukiomi Nakade
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Yoshio Sumida
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| |
Collapse
|
37
|
Inoue T, Suzuki Y, Okumura F, Naitoh I, Sano H, Ibusuki M, Kitano R, Kobayashi Y, Ito K, Yoneda M. Intraductal placement of a fully covered metal stent with a long string for distal malignant biliary obstruction without endoscopic sphincterotomy: Prospective multi-center feasibility study. Dig Endosc 2020; 32:949-956. [PMID: 31898346 DOI: 10.1111/den.13614] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/20/2019] [Revised: 12/12/2019] [Accepted: 12/19/2019] [Indexed: 02/08/2023]
Abstract
BACKGROUND Stent migration and sludge clogging are characteristic problems in biliary covered self-expandable metal stent (SEMS) placement. Intraductal placement without endoscopic sphincterotomy (ES) may help reduce their occurrence. We examined the feasibility of intraductal placement of a covered SEMS with a long string without ES in patients with unresectable distal malignant biliary obstruction (MBO). METHODS This was a prospective multi-center observational study. Forty patients with distal MBO were enrolled between July 2016 and August 2018. We evaluated recurrent biliary obstruction (RBO), adverse events other than RBO, and reintervention associated with intraductal placement without ES. RESULTS Both technical and functional success rates were 100% (40/40). The rate of adverse events other than RBO was 5% (2/40). The RBO rate was 33% (13/40), and the median time to RBO was 339 days. RBO was mainly caused by overgrowth on the papillary side, occurring in six patients; all such patients had pancreatic cancer and a distance between the papilla and the stricture of ≤20 mm. Other causes were overgrowth at the hepatic side in two patients and sludge in five patients. No instances of stent migration occurred. Success rates of endoscopic transpapillary reintervention and stent removal using the string were 92% (12/13) and 77% (10/13), respectively. CONCLUSIONS Intraductal placement without ES using a long-stringed covered SEMS is a promising option for distal MBO. Since overgrowth on the papillary side is frequent, the procedure should be avoided in patients with short distances between the stricture and the papilla. (Clinical Trial Registry: UMIN000023370).
Collapse
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Yuta Suzuki
- Department of Gastroenterology, Gifu Prefectural Tajimi Hospital, Gifu, Japan
| | - Fumihiro Okumura
- Department of Gastroenterology, Gifu Prefectural Tajimi Hospital, Gifu, Japan
| | - Itaru Naitoh
- Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, Aichi, Japan
| | - Hitoshi Sano
- Department of Gastroenterology, Toyokawa City Hospital, Aichi, Japan
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| |
Collapse
|
38
|
Inoue T, Ibusuki M, Kitano R, Kobayashi Y, Ohashi T, Nakade Y, Sumida Y, Ito K, Yoneda M. Endobiliary radiofrequency ablation combined with bilateral metal stent placement for malignant hilar biliary obstruction. Endoscopy 2020; 52:595-599. [PMID: 32208498 DOI: 10.1055/a-1133-4448] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
BACKGROUND The effectiveness of endobiliary radiofrequency ablation (RFA) is still uncertain, especially in patients with malignant hilar biliary obstruction (MHBO). We examined the efficacy of endobiliary RFA followed by bilateral self-expandable metal stent (SEMS) placement for unresectable MHBO. METHODS 41 patients met the eligibility criteria for study inclusion. We evaluated the technical success, functional success, and recurrent biliary obstruction (RBO) associated with RFA with bilateral SEMS placement. RESULTS The technical and functional success rates were both 95.1 % (39/41). The RBO rate was 38.5 % (15/39), and the median time to RBO was 230 days. Stricture length was positively correlated with time to RBO in the multivariate analysis (P = 0.03). The median time to RBO was significantly longer in patients with strictures > 15 mm in length than in those with strictures ≤ 15 mm (314 vs. 156 days; P = 0.02). CONCLUSIONS The present study showed that endobiliary RFA with bilateral SEMS placement achieved good results, but selection of patients with an appropriate stricture length may be needed to obtain a sufficient ablative effect.
Collapse
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Tomohiko Ohashi
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Yukiomi Nakade
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Yoshio Sumida
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| |
Collapse
|
39
|
Ibusuki M, Inoue T, Kitano R, Sakamoto K, Kimoto S, Kobayashi Y, Ohashi T, Sumida Y, Nakade Y, Ito K, Yoneda M. Gemcitabine plus nab-paclitaxel with initial dose reduction for older patients with advanced pancreatic cancer. J Geriatr Oncol 2020; 12:118-121. [PMID: 32576518 DOI: 10.1016/j.jgo.2020.06.017] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2020] [Revised: 05/11/2020] [Accepted: 06/15/2020] [Indexed: 11/16/2022]
Abstract
OBJECTIVES For older patients with pancreatic cancer (PC), the benefits of gemcitabine plus nab-paclitaxel (GnP) are still uncertain, and the toxicity may be excessive. We aimed to examine the efficacy and safety of modified GnP (m-GnP), which is a nab-paclitaxel reduced regimen, for older patients (≥75 years) with advanced PC. MATERIALS AND METHODS In total, 34 patients met the eligibility criteria for study inclusion between 2015 and 2020. We evaluated the overall survival (OS), progression-free survival (PFS), best response, and adverse events associated with m-GnP treatment. RESULTS The median OS and PFS were 15.4 months and 5.9 months, respectively. The best response was partial response in 29% (10/34), stable disease in 53% (18/34), and progressive disease in 15% of patients (5/34); one patient was not evaluated. Among the grade 3 or higher hematological adverse events, neutropenia was the most frequent, occurring in 38% of patients (13/34), whereas febrile neutropenia occurred in 3% (1/34). Grade 3 or higher non-hematological adverse events occurred in 12% of patients (4/34). Early discontinuation owing to intolerable adverse events occurred in one patient, and there were no chemotherapy-related deaths. CONCLUSIONS The present study demonstrated that m-GnP exhibited good efficacy with acceptable toxicity. To avoid early discontinuation and maintain dose intensities, initial dose reduction may be a good option for older patients with PC when receiving GnP.
Collapse
Affiliation(s)
- Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195, Japan
| | - Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195, Japan.
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195, Japan
| | - Kazumasa Sakamoto
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195, Japan
| | - Satoshi Kimoto
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195, Japan
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195, Japan
| | - Tomohiko Ohashi
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195, Japan
| | - Yoshio Sumida
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195, Japan
| | - Yukiomi Nakade
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195, Japan
| |
Collapse
|
40
|
Shinriki S, Maeshiro M, Shimamura K, Kawashima J, Araki E, Ibusuki M, Yamamoto Y, Iwase H, Miyamoto Y, Baba H, Yamaguchi M, Matsui H. Evaluation of an amplicon-based custom gene panel for the diagnosis of hereditary tumors. Neoplasma 2020; 67:898-908. [PMID: 32241160 DOI: 10.4149/neo_2020_190918n925] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2019] [Accepted: 11/06/2019] [Indexed: 11/08/2022]
Abstract
Genetic testing based on next-generation sequencing (NGS) analysis has recently been used to diagnose hereditary diseases. In this study, we explored the usefulness of our custom amplicon panel that targeted 23 genes related to hereditary tumors given in the American College of Medical Genetics and Genomics recommendations. We applied our custom NGS panel to samples from 12 patients previously diagnosed by Sanger sequencing as having the diseases or diagnosed clinically by meeting the diagnostic criteria in this study. Our gene panel not only successfully identified all variants detected by Sanger sequencing but also identified previously unrecognized variants that resulted in confirmation of the disease, or even in the revision of the diagnosis. For instance, a patient identified with an SDHD gene mutation actually had von Hippel-Lindau (VHL) syndrome, as determined by the presence of a pathogenic VHL gene variant. We also identified false-positive results that were generated by amplification of genome regions that are not intended to be investigated. In conclusion, NGS-based amplicon sequencing is a highly effective method to detect germline variants, as long as they are also carefully reviewed by manual inspection.
Collapse
Affiliation(s)
- S Shinriki
- Department of Molecular Laboratory Medicine, Graduate School of Medical Sciences, Kumamoto University, Kumamoto, Japan.,Department of Laboratory Medicine, Kumamoto University Hospital, Kumamoto, Japan
| | - M Maeshiro
- Department of Laboratory Medicine, Kumamoto University Hospital, Kumamoto, Japan.,Department of Oral and Maxillofacial Surgery, Graduate School of Medical Sciences, Kumamoto University, Kumamoto, Japan
| | - K Shimamura
- Department of Molecular Laboratory Medicine, Graduate School of Medical Sciences, Kumamoto University, Kumamoto, Japan.,Department of Laboratory Medicine, Kumamoto University Hospital, Kumamoto, Japan
| | - J Kawashima
- Department of Metabolic Medicine, Graduate School of Medical Sciences, Kumamoto University, Kumamoto, Japan
| | - E Araki
- Department of Metabolic Medicine, Graduate School of Medical Sciences, Kumamoto University, Kumamoto, Japan
| | - M Ibusuki
- Department of Breast and Endocrine Surgery, Graduate School of Medical Sciences, Kumamoto University, Kumamoto, Japan
| | - Y Yamamoto
- Department of Breast and Endocrine Surgery, Graduate School of Medical Sciences, Kumamoto University, Kumamoto, Japan
| | - H Iwase
- Department of Breast and Endocrine Surgery, Graduate School of Medical Sciences, Kumamoto University, Kumamoto, Japan
| | - Y Miyamoto
- Department of Gastroenterological Surgery, Graduate School of Medical Sciences, Kumamoto University, Kumamoto, Japan
| | - H Baba
- Department of Gastroenterological Surgery, Graduate School of Medical Sciences, Kumamoto University, Kumamoto, Japan
| | | | - H Matsui
- Department of Molecular Laboratory Medicine, Graduate School of Medical Sciences, Kumamoto University, Kumamoto, Japan.,Department of Laboratory Medicine, Kumamoto University Hospital, Kumamoto, Japan
| |
Collapse
|
41
|
Inoue T, Tsuzuki T, Takahara T, Ibusuki M, Kitano R, Kobayashi Y, Ohashi T, Nakade Y, Sumida Y, Ito K, Yoneda M. Prospective evaluation of 25-gauge Franseen needles for endoscopic ultrasound-guided fine-needle biopsy of solid pancreatic masses. Endosc Int Open 2020; 8:E566-E570. [PMID: 32258381 PMCID: PMC7089784 DOI: 10.1055/a-1119-6673] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/01/2019] [Accepted: 01/23/2020] [Indexed: 02/07/2023] Open
Abstract
Background and study aims The ideal puncture needle for endoscopic ultrasound (EUS)-guided sampling is maneuverable and easy to puncture with, and can obtain sufficient material in almost one pass. The novel 25-gauge Franseen needle may provide a good balance between maneuverability and sample yield. Patients and methods Between July 2017 and December 2018, 116 patients with solid pancreatic masses were prospectively enrolled and investigated. We evaluated the diagnostic yield associated with using the 25-gauge Franseen needle for EUS-guided sampling of pancreatic masses. Results The technical success rate was 100 % (116/116). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for malignancy were 98 % (105/107), 100 % (9/9), 100 % (105/105), 82 % (9/11), and 98 % (114/116), respectively. Cumulative sensitivities for malignancy were 87 % (93/107) on pass 1, 97 % (104/107) on pass 2, and 98 % (105/107) on pass 3, respectively, with no increase in sensitivity after 4 or more. An adequate specimen for histological assessment was obtained in 79 % (92/116) of cases. Multivariate logistic analyses showed that lesion size smaller than 13 mm was a risk factor for failure of obtaining an adequate specimen for histological assessment ( P = 0.010) Conclusions The novel 25-gauge Franseen needle showed excellent diagnostic yield for solid pancreatic masses. However, its ability to obtain an adequate specimen for histological assessment may still be insufficient, especially when dealing with small lesions.
Collapse
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, Nagakute, Aichi, Japan
| | - Toyonori Tsuzuki
- Department of Surgical Pathology, Aichi Medical University, Nagakute, Aichi, Japan
| | - Taishi Takahara
- Department of Surgical Pathology, Aichi Medical University, Nagakute, Aichi, Japan
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, Nagakute, Aichi, Japan
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, Nagakute, Aichi, Japan
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, Nagakute, Aichi, Japan
| | - Tomohiko Ohashi
- Department of Gastroenterology, Aichi Medical University, Nagakute, Aichi, Japan
| | - Yukiomi Nakade
- Department of Gastroenterology, Aichi Medical University, Nagakute, Aichi, Japan
| | - Yoshio Sumida
- Department of Gastroenterology, Aichi Medical University, Nagakute, Aichi, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, Nagakute, Aichi, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, Nagakute, Aichi, Japan
| |
Collapse
|
42
|
Inoue T, Ibusuki M, Kitano R, Kobayashi Y, Ito K, Yoneda M. A novel large cell-sized stent with slim delivery for combined side-by-side and stent-in-stent placement in malignant hilar biliary obstruction. Endoscopy 2020; 52:E104-E105. [PMID: 31593989 DOI: 10.1055/a-1015-6522] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, Nagakute
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, Nagakute
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, Nagakute
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, Nagakute
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, Nagakute
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, Nagakute
| |
Collapse
|
43
|
Inoue T, Ibusuki M, Kitano R, Kobayashi Y, Ito K, Yoneda M. Covered self-expandable metal stent placement for post-endoscopic sphincterotomy bleeding in a patient with surgically altered anatomy. Endoscopy 2020; 52:E13-E14. [PMID: 31398737 DOI: 10.1055/a-0978-4815] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195, Japan
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195, Japan
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195, Japan
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195, Japan
| |
Collapse
|
44
|
Inoue T, Ibusuki M, Kitano R, Kobayashi Y, Ito K, Yoneda M. Removing a metal stent using a string following endoscopic ultrasound-guided antegrade placement for pancreaticojejunostomy stricture. Endoscopy 2020; 52:E39-E40. [PMID: 31434151 DOI: 10.1055/a-0989-2321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| |
Collapse
|
45
|
Inoue T, Ibusuki M, Kitano R, Kobayashi Y, Ohashi T, Nakade Y, Sumida Y, Ito K, Nakao H, Yoneda M. Combined side-by-side and stent-in-stent method for triple metal stenting in patients with malignant hilar biliary obstruction. Dig Endosc 2019; 31:698-705. [PMID: 31120163 DOI: 10.1111/den.13448] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/10/2019] [Accepted: 05/19/2019] [Indexed: 02/08/2023]
Abstract
BACKGROUND AND AIM Endoscopic placement of three branched self-expandable metallic stents (SEMS) for high-grade malignant hilar biliary obstruction (MHBO) is technically challenging. We examined the feasibility and efficacy of a novel stenting method combining side-by-side and stent-in-stent (SBSIS) placement for MHBO. METHODS Between January 2015 and December 2018, 27 consecutive patients with high-grade MHBO underwent SBSIS placement. We evaluated the technical success, functional success, recurrent biliary obstruction (RBO), adverse events other than RBO, and reintervention success rates associated with SBSIS placement. RESULTS Technical success rate was 85% (23/27). Insertion of the third SEMS failed in four patients, and median diameter of the common bile duct (CBD) was significantly smaller in patients in whom technical failure occurred (5 mm vs 8 mm; P = 0.004). Functional success was achieved in all patients in whom the procedure was a technical success. Rate of adverse events other than RBO was 15% (4/27). RBO rate was 43% (10/23), and median time to RBO was 157 days. Success rate of endoscopic reintervention for RBO was 89% (8/9). CONCLUSION SBSIS placement showed favorable results and is a promising option in patients with high-grade MHBO requiring triple metal stenting. However, it might be preferable to avoid SBSIS in patients with a narrow CBD. Clinical Trial Registry: UMIN000035721.
Collapse
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Tomohiko Ohashi
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Yukiomi Nakade
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Yoshio Sumida
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Haruhisa Nakao
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| |
Collapse
|
46
|
Inoue T, Ibusuki M, Kitano R, Kobayashi Y, Ohashi T, Nakade Y, Sumida Y, Ito K, Nakao H, Yoneda M. Balloon enteroscopy-assisted radial incision and cutting method for refractory hepaticojejunostomy anastomotic strictures. Endoscopy 2019; 51:566-570. [PMID: 30759466 DOI: 10.1055/a-0838-5557] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Abstract
BACKGROUND Balloon enteroscopy-assisted balloon dilation and temporary biliary stent placement are effective for hepaticojejunostomy anastomotic strictures (HJAS), but the re-stenosis rates are relatively high. We examined the feasibility and efficacy of a novel treatment technique for refractory HJAS, called balloon enteroscopy-assisted radial incision and cutting (BE-RIC). METHODS Between January 2016 and June 2018, 11 patients with refractory HJAS that recurred after balloon dilation and/or stent placement, underwent BE-RIC. We evaluated the technical success, clinical success, adverse events, and re-stenosis rates associated with BE-RIC. RESULTS The technical success rate of BE-RIC was 91 % (10/11). Clinical success was achieved in all patients who underwent technically successful procedures. The procedure-related adverse event rate was 9 % (1/11). No re-stenosis was observed during the follow-up period; 9 patients were followed up for more than 6 months, and of these, 5, 4, and 2 patients were followed up for more than 12, 18, and 24 months, respectively, without re-stenosis. CONCLUSIONS BE-RIC for refractory HJAS showed favorable results. BE-RIC might be a useful option for treating refractory HJAS.
Collapse
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Tomohiko Ohashi
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Yukiomi Nakade
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Yoshio Sumida
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Haruhisa Nakao
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| |
Collapse
|
47
|
Inoue T, Ibusuki M, Kitano R, Kobayashi Y, Ishii N, Ohashi T, Nakade Y, Sumida Y, Ito K, Nakao H, Yoneda M. Severe Biliary Stricture Dilation Using the Soehendra Stent Retriever with a Short-Type Balloon Enteroscope in Patients with Surgically Altered Anatomies. J Gastrointest Surg 2019; 23:953-958. [PMID: 30284198 DOI: 10.1007/s11605-018-3977-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/09/2018] [Accepted: 09/13/2018] [Indexed: 01/31/2023]
Abstract
BACKGROUND Balloon enteroscopy (BE) can be used for endoscopic retrograde cholangiography (ERC) to treat biliary strictures in patients with surgically altered anatomies. However, biliary strictures, including bilioenteric anastomotic strictures, are often very severe and dilation catheters cannot pass through them. The Soehendra stent retriever (SSR) is like a screw drill and can be useful for dilating severe strictures, but the utility of SSR during BE-assisted ERC (BE-ERC) is unclear. This study aimed to examine the efficacy and safety of a dilation technique using the SSR during BE-ERC. METHODS Between 2014 and 2018, 28 patients with surgically altered gastrointestinal anatomies and severe biliary strictures underwent BE-ERC, and the SSR was used for the dilation procedures. We evaluated the technical success, therapeutic success, and adverse event rates associated with SSR dilation. RESULTS The technical success rate was 93% (26/28). The procedures undertaken on two patients with non-anastomotic strictures failed technically because the SSR was not long enough to reach the strictures. The therapeutic success rate was 96% (25/26) for the patients whose procedures were technically successful. The adverse event rate was 7% (2/28), and the adverse events were mild and improved with conservative management. No bleeding or duct perforations occurred. CONCLUSIONS Although the indications for using the SSR in patients with non-anastomotic strictures should be considered based on the distance between the tip of the scope and the stricture's location, SSR dilation may be a useful option during BE-ERC if a biliary stricture is very severe.
Collapse
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan.
| | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Norimitsu Ishii
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Tomohiko Ohashi
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Yukiomi Nakade
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Yoshio Sumida
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Haruhisa Nakao
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| |
Collapse
|
48
|
Inoue T, Okumura F, Sano H, Mizushima T, Tsukamoto H, Fujita Y, Ibusuki M, Kitano R, Kobayashi Y, Ishii N, Ito K, Yoneda M. Impact of endoscopic ultrasound-guided fine-needle biopsy on the diagnosis of subepithelial tumors: A propensity score-matching analysis. Dig Endosc 2019; 31:156-163. [PMID: 30171772 DOI: 10.1111/den.13269] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/25/2018] [Accepted: 08/28/2018] [Indexed: 02/08/2023]
Abstract
BACKGROUND AND AIM Immunohistological evaluations are essential for diagnosing subepithelial tumors (SET). However, endoscopic ultrasound-guided sampling using fine-needle aspiration (FNA) needles is limited in its ability to procure core tissue for immunostaining. Fine-needle biopsy (FNB) needles may mitigate this limitation. The present study aimed to examine the efficacy of FNB needles for procuring samples that enable the diagnosis of SET. METHODS One hundred sixty patients were included in the study and separated into those whose samples were obtained using FNB needles (FNB group) and those whose samples were procured using FNA needles (FNA group). Groups were compared regarding the conclusive diagnosis rate and unwarranted resection rate. Propensity score matching was introduced to reduce selection bias. RESULTS Rates at which conclusive diagnoses were reached through adequate immunohistological evaluations were 82% and 60% in the FNB and FNA groups, respectively; this difference was significant (P = 0.013). Unwarranted resection rate was significantly lower in the FNB group (2%) than in the FNA group (14%; P = 0.032). Multivariate analyses showed that lesions ≤20 mm were a significant risk factor for lower conclusive diagnosis rates following the use of FNB needles (P = 0.017). CONCLUSIONS Fine-needle biopsy needles can be useful for obtaining samples that facilitate the diagnosis of SET and for avoiding unwarranted resections. However, FNB needles may be less advantageous for small SET.
Collapse
Affiliation(s)
- Tadahisa Inoue
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | | | | | | | | | | | - Mayu Ibusuki
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Rena Kitano
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Yuji Kobayashi
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Norimitsu Ishii
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Kiyoaki Ito
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| | - Masashi Yoneda
- Department of Gastroenterology, Aichi Medical University, Aichi, Japan
| |
Collapse
|
49
|
Sueta A, Yamamoto Y, Tomiguchi M, Takeshita T, Ibusuki M, Iwase H. Abstract P1-02-13: Differential expression of exosomal miRNAs between breast cancer patients with recurrence and no-recurrence. Cancer Res 2017. [DOI: 10.1158/1538-7445.sabcs16-p1-02-13] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Abstract
Background
In recent years, there has been a concerted effort to identify biomarkers derived from body fluid in various cancers. Exosomal microRNA (miRNA) has been used as one of useful diagnostic or prognostic biomarkers. We aimed to investigate the prognostic role of the exosomal miRNAs in serum samples derived from patients with primary breast cancer. Additionally, we evaluated whether the exosomal miRNA in serum reflect the origin of primary tumor by means of comparing their expression levels between in serum and tumors.
Patients and Methods
Exosomes in serum sample (500uL) were extracted using ExoQuick (System Biosciences) and miRNAs were isolated using SeraMirTM Exosome RNA Amplification Kit (SBI). We compared the miRNA profile derived from exosome between the patients with breast cancer with recurrence (n=16) and without recurrence (n=16) by miRNA PCR array. Further, we examined the expression of miRNA derived from tumor tissues in the patients with breast cancer recurrence (n=35) and without recurrence (n=39) by qRT-PCR. All samples were collected before treatment and surgery.
Results
Of the 384 miRNAs, 11 miRNAs were significantly expressed; three miRNAs (miR-338-3p, miR-340-5p, and miR-124-3p) were significantly up-regulated and eight (miR-29b-3p, miR-20b-5p, miR-17-5p, miR-130a-3p, miR-18a-5p, miR-195-5p, miR-486-5p, and miR-93a-5p) were significantly down-regulated in the patients with recurrence compared to those without recurrence. Next, we evaluated expression of the above miRNAs in tumor tissues. The patients with recurrence have higher levels of miR-340 at their primary site as well as in the serum. On the contrary, miR-195-5p, miR-17-5p, miR-93-5p, and miR-130a-3p derived from tumor tissues that were down-regulated in the patients with recurrence in serum, were highly expressed in the patients with recurrence than those with no-recurrence. In logistic regression analysis, tumor size, miR-340-5p, miR-17-5p, miR-130a-3p, and miR-93-5p were significantly associated with breast cancer recurrence (each P < 0.05).
Conclusions
Several exosomal miRNAs at diagnosis may be useful biomarker to predict the breast cancer recurrence. Moreover, we showed the different expression pattern of miRNAs between tumor tissues and serum. These findings may suggest selective mechanism of release of exosomal miRNA by cancer cells to regulate their progression. Further studies to confirm our results are needed.
Citation Format: Sueta A, Yamamoto Y, Tomiguchi M, Takeshita T, Ibusuki M, Iwase H. Differential expression of exosomal miRNAs between breast cancer patients with recurrence and no-recurrence [abstract]. In: Proceedings of the 2016 San Antonio Breast Cancer Symposium; 2016 Dec 6-10; San Antonio, TX. Philadelphia (PA): AACR; Cancer Res 2017;77(4 Suppl):Abstract nr P1-02-13.
Collapse
Affiliation(s)
- A Sueta
- Kumamoto University Graduate School of Medical Science, Japan
| | - Y Yamamoto
- Kumamoto University Graduate School of Medical Science, Japan
| | - M Tomiguchi
- Kumamoto University Graduate School of Medical Science, Japan
| | - T Takeshita
- Kumamoto University Graduate School of Medical Science, Japan
| | - M Ibusuki
- Kumamoto University Graduate School of Medical Science, Japan
| | - H Iwase
- Kumamoto University Graduate School of Medical Science, Japan
| |
Collapse
|
50
|
Yano Y, Okamoto H, Onitsuka M, Mori N, Nakamura M, Hisama S, Nosaka K, Ibusuki M, Yamamoto Y, Iwase H. Does Local Anesthetic Patch Reduce the Injection Site Pain of Fulvestrant in Postmenopausal Breast Cancer? Ann Oncol 2013. [DOI: 10.1093/annonc/mdt460.121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|