26
|
Hopke PK, Ito K, Mar T, Christensen WF, Eatough DJ, Henry RC, Kim E, Laden F, Lall R, Larson TV, Liu H, Neas L, Pinto J, Stölzel M, Suh H, Paatero P, Thurston GD. PM source apportionment and health effects: 1. Intercomparison of source apportionment results. JOURNAL OF EXPOSURE SCIENCE & ENVIRONMENTAL EPIDEMIOLOGY 2006; 16:275-86. [PMID: 16249798 DOI: 10.1038/sj.jea.7500458] [Citation(s) in RCA: 95] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
During the past three decades, receptor models have been used to identify and apportion ambient concentrations to sources. A number of groups are employing these methods to provide input into air quality management planning. A workshop has explored the use of resolved source contributions in health effects models. Multiple groups have analyzed particulate composition data sets from Washington, DC and Phoenix, AZ. Similar source profiles were extracted from these data sets by the investigators using different factor analysis methods. There was good agreement among the major resolved source types. Crustal (soil), sulfate, oil, and salt were the sources that were most unambiguously identified (generally highest correlation across the sites). Traffic and vegetative burning showed considerable variability among the results with variability in the ability of the methods to partition the motor vehicle contributions between gasoline and diesel vehicles. However, if the total motor vehicle contributions are estimated, good correspondence was obtained among the results. The source impacts were especially similar across various analyses for the larger mass contributors (e.g., in Washington, secondary sulfate SE=7% and 11% for traffic; in Phoenix, secondary sulfate SE=17% and 7% for traffic). Especially important for time-series health effects assessment, the source-specific impacts were found to be highly correlated across analysis methods/researchers for the major components (e.g., mean analysis to analysis correlation, r>0.9 for traffic and secondary sulfates in Phoenix and for traffic and secondary nitrates in Washington. The sulfate mean r value is >0.75 in Washington.). Overall, although these intercomparisons suggest areas where further research is needed (e.g., better division of traffic emissions between diesel and gasoline vehicles), they provide support the contention that PM(2.5) mass source apportionment results are consistent across users and methods, and that today's source apportionment methods are robust enough for application to PM(2.5) health effects assessments.
Collapse
|
27
|
Wilson WE, Grover BD, Long RW, Eatough NL, Eatough DJ. The measurement of fine particulate semivolatile material in urban aerosols. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION (1995) 2006; 56:384-97. [PMID: 16681204 DOI: 10.1080/10473289.2006.10464527] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Ammonium nitrate and semivolatile organic material (SVOM) are significant components of fine particles in urban atmospheres. These components, however, are not properly determined with methods such as the fine particulate matter (PM2.5) Federal Reference Method (FRM) or other single filter samplers because of significant losses of semivolatile material (SVM) from particles collected on the filter during sampling. The R&P tapered element oscillating microbalance (TEOM) monitor also does not measure SVM, because this method heats the sample to remove particle bound water, which also results in evaporation of SVM. Recent advances in monitoring techniques have resulted in samplers for both integrated and continuous measurement of total PM2.5, including the particle concentrator-Brigham Young University organic sampling system (PC-BOSS), the real-time total ambient mass sampler (RAMS), and the R&P filter dynamics measurement system (FDMS) TEOM monitor. Results obtained using these samplers have been compared with those obtained with either a PM2.5 FRM sampler or a TEOM monitor in studies conducted during the past five years. These studies have shown the following: (1) the PC-BOSS, RAMS, and FDMS TEOM are all comparable. Each instrument measures both the nonvolatile material and the SVM. (2) The SVM is not retained on the heated filter of a regular TEOM monitor and is not measured by this sampling technique. (3) Much of the SVM is also lost during sampling from single filter samplers such as the PM2.5 FRM sampler. (4) The amount of SVM lost from single filter samplers can vary from less than one-third of that lost from heated TEOM filters during cold winter conditions to essentially all during warm summer conditions. (5) SVOM can only be reliably collected using an appropriate denuder sampler. (6) A PM2.5 speciation sampler can be easily modified to a denuder sampler with filters that can be analyzed for semivolatile organic carbon (OC), nonvolatile OC, and elemental carbon using existing OC/elemental carbon analytical techniques. The research upon which these statements are based for various urban studies are summarized in this paper.
Collapse
|
28
|
Long RW, Eatough NL, Eatough DJ, Meyer MB, Wilson WE. Continuous determination of fine particulate matter mass in the Salt Lake City Environmental Monitoring project: a comparison of real-time and conventional TEOM monitor results. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION (1995) 2005. [PMID: 16408688 DOI: 10.1080/10473289.2005.10464776] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Fine particulate matter (PM2.5) mass was determined on a continuous basis at the Salt Lake City Environmental Protection Agency Environmental Monitoring for Public Awareness and Community Tracking monitoring site in Salt Lake City, UT, using three different monitoring techniques. Hourly averaged PM2.5 mass data were collected during two sampling periods (summer 2000 and winter 2002) using a real-time total ambient mass sampler (RAMS), sample equilibration system (SES)-tapered element oscillating microbalance (TEOM), and conventional TEOM monitor. This paper compares the results obtained from the various monitoring systems, which differ in their treatment of semivolatile material (SVM; particle-bound water, semivolatile ammonium nitrate, and semivolatile organic compounds). PM2.5 mass results obtained by the RAMS were consistently higher than those obtained by the SES-TEOM and conventional TEOM monitors because of the RAMS ability to measure semivolatile ammonium nitrate and semivolatile organic material but not particle-bound water. The SES-TEOM monitoring system was able to account for an average of 28% of the SVM, whereas the conventional TEOM monitor loses essentially all of the SVM from the single filter during sampling. Occasional mass readings by the various TEOM monitors that are higher than RAMS results may reflect particle-bound water, which, under some conditions, is measured by the TEOM but not the RAMS.
Collapse
|
29
|
Thurston GD, Ito K, Mar T, Christensen WF, Eatough DJ, Henry RC, Kim E, Laden F, Lall R, Larson TV, Liu H, Neas L, Pinto J, Stölzel M, Suh H, Hopke PK. Workgroup report: workshop on source apportionment of particulate matter health effects--intercomparison of results and implications. ENVIRONMENTAL HEALTH PERSPECTIVES 2005; 113:1768-74. [PMID: 16330361 PMCID: PMC1314918 DOI: 10.1289/ehp.7989] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/31/2005] [Accepted: 09/01/2005] [Indexed: 05/05/2023]
Abstract
Although the association between exposure to ambient fine particulate matter with aerodynamic diameter < 2.5 microm (PM2.5) and human mortality is well established, the most responsible particle types/sources are not yet certain. In May 2003, the U.S. Environmental Protection Agency's Particulate Matter Centers Program sponsored the Workshop on the Source Apportionment of PM Health Effects. The goal was to evaluate the consistency of the various source apportionment methods in assessing source contributions to daily PM2.5 mass-mortality associations. Seven research institutions, using varying methods, participated in the estimation of source apportionments of PM2.5 mass samples collected in Washington, DC, and Phoenix, Arizona, USA. Apportionments were evaluated for their respective associations with mortality using Poisson regressions, allowing a comparative assessment of the extent to which variations in the apportionments contributed to variability in the source-specific mortality results. The various research groups generally identified the same major source types, each with similar elemental makeups. Intergroup correlation analyses indicated that soil-, sulfate-, residual oil-, and salt-associated mass were most unambiguously identified by various methods, whereas vegetative burning and traffic were less consistent. Aggregate source-specific mortality relative risk (RR) estimate confidence intervals overlapped each other, but the sulfate-related PM2.5 component was most consistently significant across analyses in these cities. Analyses indicated that source types were a significant predictor of RR, whereas apportionment group differences were not. Variations in the source apportionments added only some 15% to the mortality regression uncertainties. These results provide supportive evidence that existing PM2.5 source apportionment methods can be used to derive reliable insights into the source components that contribute to PM2.5 health effects.
Collapse
|
30
|
Anderson RR, Martello DV, White CM, Crist KC, John K, Modey WK, Eatough DJ. The regional nature of PM2.5 episodes in the upper Ohio River Valley. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION (1995) 2004; 54:971-984. [PMID: 15373365 DOI: 10.1080/10473289.2004.10470967] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
From October 1999 through September 2000, particulate matter (PM) with aerodynamic diameter > or =2.5 microm (PM2.5) mass and composition were measured at the National Energy Technology Laboratory Pittsburgh site, with a particle concentrator Brigham Young University-organic sampling system and a tapered element oscillating microbalance (TEOM) monitor. PM2.5 measurements had also been obtained with TEOM monitors located in the Pittsburgh, PA, area, and at sites in Ohio, including Steubenville, Columbus, and Athens. The PM data from all these sites were analyzed on high PM days; PM2.5 TEOM particulate mass at all sites was generally associated with transitions from locally high barometric pressure to lower pressure. Elevated concentrations occurred with transport of PM from outside the local region in advance of frontal passages as the local pressure decreased. During high-pressure periods, concentrations at the study sites were generally low throughout the study region. Further details related to this transport were obtained from surface weather maps and estimated back-trajectories using the hybrid single-particle Lagrangian integrated trajectory model associated with these time periods. These analyses indicated that transport of pollutants to the Pittsburgh site was generally from the west to the southwest. These results suggest that the Ohio River Valley and possible regions beyond act as a significant source of PM and its precursors in the Pittsburgh area and at the other regional sites included in this study.
Collapse
|
31
|
Hidy GM, Eatough DJ, Klouda GA. Design scenario for the radioisotopic estimation of the biogenic component of airborne particles. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION (1995) 2004; 54:600-613. [PMID: 15149047 DOI: 10.1080/10473289.2004.10470929] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
An experimental design is described to estimate the fraction of secondary fine particle from the biogenic component of volatile organic compounds (VOCs) in the atmosphere using radiocarbon isotopic abundance ratios. The method distinguishes between "modern" carbon (C), and "old" C of primary and secondary origins based on three components, condensed-phase organic carbon (OC), semi-volatile particulate compounds (SVOCs), and VOCs. The method depends on interpretation of diurnal and seasonal variation in OC, SVOC, and VOC concentrations. Sampling employs a filter-denuder unit, which collects the three C components for isotopic analysis. The samples are collected repetitively for a daily sequence of the same hourly intervals covering diurnal periods with similar meteorological conditions. Collected C is thermally treated to separate OC from black carbon on filters and VOCs or SVOCs from adsorbents, with all four fractions individually oxidized to carbon dioxide to determine the radiocarbon content by accelerator mass spectrometry. Using C isotope abundance, the data are interpreted for fractions of primary modern C and secondary modern C as estimated from averaging diurnal and seasonal variations in the concentration data. As support for interpretation, samples of OC, SVOCs, and VOCs would be analyzed for speciation to identify source indicator species present.
Collapse
|
32
|
Pope CA, Hansen ML, Long RW, Nielsen KR, Eatough NL, Wilson WE, Eatough DJ. Ambient particulate air pollution, heart rate variability, and blood markers of inflammation in a panel of elderly subjects. ENVIRONMENTAL HEALTH PERSPECTIVES 2004; 112:339-45. [PMID: 14998750 PMCID: PMC1241864 DOI: 10.1289/ehp.6588] [Citation(s) in RCA: 327] [Impact Index Per Article: 16.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
Epidemiologic studies report associations between particulate air pollution and cardiopulmonary morbidity and mortality. Although the underlying pathophysiologic mechanisms remain unclear, it has been hypothesized that altered autonomic function and pulmonary/systemic inflammation may play a role. In this study we explored the effects of air pollution on autonomic function measured by changes in heart rate variability (HRV) and blood markers of inflammation in a panel of 88 elderly subjects from three communities along the Wasatch Front in Utah. Subjects participated in multiple sessions of 24-hr ambulatory electrocardiographic monitoring and blood tests. Regression analysis was used to evaluate associations between fine particulate matter [aerodynamic diameter less than or equal to 2.5 microm (PM2.5)] and HRV, C-reactive protein (CRP), blood cell counts, and whole blood viscosity. A 100- microg/m3 increase in PM2.5 was associated with approximately a 35 (SE = 8)-msec decline in standard deviation of all normal R-R intervals (SDNN, a measure of overall HRV); a 42 (SE = 11)-msec decline in square root of the mean of the squared differences between adjacent normal R-R intervals (r-MSSD, an estimate of short-term components of HRV); and a 0.81 (SE = 0.17)-mg/dL increase in CRP. The PM2.5-HRV associations were reasonably consistent and statistically robust, but the CRP association dropped to 0.19 (SE = 0.10) after excluding the most influential subject. PM2.5 was not significantly associated with white or red blood cell counts, platelets, or whole-blood viscosity. Most short-term variability in temporal deviations of HRV and CRP was not explained by PM2.5; however, the small statistically significant associations that were observed suggest that exposure to PM2.5 may be one of multiple factors that influence HRV and CRP.
Collapse
|
33
|
Modey WK, Eatough DJ. Trends in PM2.5 composition at the Department of Energy OST NETL fine particle characterization site in Pittsburgh, PA, USA. ACTA ACUST UNITED AC 2003. [DOI: 10.1016/s1093-0191(02)00081-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
34
|
Hansen LD, Whiting L, Eatough DJ, Jensen TE, Izatt RM. Determination of sulfur(IV) and sulfate in aerosols by thermometric methods. Anal Chem 2002. [DOI: 10.1021/ac60368a003] [Citation(s) in RCA: 41] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
35
|
Eatough DJ, Salim S, Izatt RM, Christensen JJ, Hansen LD. Calorimetric investigation of adsorption of aromatic compounds by Linde Molecular Sieve 13X. Anal Chem 2002. [DOI: 10.1021/ac60337a023] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
36
|
Pang Y, Eatough NL, Modey WK, Eatough DJ. Evaluation of the RAMS continuous monitor for determination of PM2.5 mass including semi-volatile material in Philadelphia, PA. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION (1995) 2002; 52:563-572. [PMID: 12022695 DOI: 10.1080/10473289.2002.10470809] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
The real-time ambient mass sampler (RAMS) is a continuous monitor based on particle concentrator, denuder, drier, and tapered element oscillating microbalance (TEOM) monitor technology. It is designed to measure PM2.5 mass, including the semi-volatile species NH4NO3 and semi-volatile organic material, but not to measure PM2.5 water content. The performance of the RAMS in an urban environment with high humidity was evaluated during the July 1999 NARSTO-Northeast Oxidant and Particles Study (NEOPS) intensive study at the Baxter water treatment plant in Philadelphia, PA. The results obtained with the RAMS were compared to mass measurements made with a TEOM monitor and to constructed mass obtained with a Particle Concentrator-Brigham Young University Organic Sampling System (PC-BOSS) sampler designed to determine the chemical composition of fine particles, including the semi-volatile species. An average of 28% of the fine particulate material present during the study was semi-volatile organic material lost from a filter during particle collection, and 1% was NH4NO3 that was also lost from the particles during sampling. The remaining mass was dominantly nonvolatile (NH4)2SO4 (31%) and organic material (37%), with minor amounts of soot, crustal material, and nonvolatile NH4NO3. Comparison of the RAMS and PC-BOSS results indicated that the RAMS correctly monitored for fine particulate mass, including the semivolatile material. In contrast, the heated filter of the TEOM monitor did not measure the semi-volatile material. The comparison of the RAMS and PC-BOSS data had a precision of +/-4.1 microg/m3 (+/-9.6%). The precision of the RAMS data was limited by the uncertainty in the blank correction for the reversible adsorption of water by the charcoal-impregnated cellulose sorbent filter of the RAMS monitor. The precision of the measurement of fine particulate components by the PC-BOSS was +/-6-8%.
Collapse
|
37
|
Eatough DJ, White VF, Hansen LD, Eatough NL, Ellis EC. Hydration of nitric acid and its collection in the atmosphere by diffusion denuders. Anal Chem 2002. [DOI: 10.1021/ac00280a038] [Citation(s) in RCA: 40] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
38
|
Warner KS, Eatough DJ, Stockburger L. Determination of fine particulate semi-volatile organic material at three eastern U.S. sampling sites. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION (1995) 2001; 51:1302-1308. [PMID: 11575883 DOI: 10.1080/10473289.2001.10464357] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Correct assessment of fine particulate carbonaceous material as a function of particle size is, in part, dependent on the determination of semi-volatile compounds, which can be lost from particles during sampling. This study gives results obtained for the collection of fine particulate carbonaceous material at three eastern U.S. sampling sites [Philadelphia, PA; Shenandoah National Park, VA; and Research Triangle Park (RTP), NC] using diffusion denuder technology. The diffusion denuder samplers allow for the determination of fine particulate organic material with no artifacts, due to the loss of semi-volatile organic particulate compounds, or collection of gas-phase organic compounds by the quartz filter during sampling. The results show that an average of 41, 43, and 59% of fine particulate organic material was lost as volatilized semi-volatile organic material during collection of particles on a filter at Philadelphia, RTP, and Shenandoah, respectively. The particle size distribution of carbonaceous material retained by a filter and lost from a filter during sampling was obtained for the samples collected at Philadelphia and Shenandoah. The carbonaceous material retained by the particles during sampling was found predominantly in particles smaller than 0.4 microm in aerodynamic diameter. In contrast, the semi-volatile organic material lost from the particles during sampling had a mass median diameter of approximately 0.5 microm.
Collapse
|
39
|
Eatough DJ, Green M, Moran W, Farber R. Potential particulate impacts at the Grand Canyon from northwestern Mexico. THE SCIENCE OF THE TOTAL ENVIRONMENT 2001; 276:69-82. [PMID: 11516140 DOI: 10.1016/s0048-9697(01)00772-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Project MOHAVE was a major air quality and visibility research program conducted from 1990 to 1999 to investigate the causes of visibility impairment in the Grand Canyon National Park region. At Meadview, a remote monitoring site just west of the Grand Canyon National Park, on September 1 and 2, 1992, the concentrations of sulfate (3.1 and 4.3 microg sulfate/m3) were the highest seen in 6 years of monitoring at this site. During this period, the concentrations of SO2 at Meadview were also abnormally high and approximately three times the sulfate concentrations, on a nmol/m3 basis. High concentrations of sulfate and SO2 extended south into southern Arizona and northwestern Mexico. Based on ambient atmospheric conditions, emissions from the Mohave Power Project (MPP) 110 km upwind of Meadview could not have been responsible for the majority of the regionally observed sulfur oxides. The geographical distribution of SO2 and sulfate, and available source information suggest that northwestern Mexico was a significant source of the unusually high observed sulfur oxides. A CMB model developed during Project MOHAVE was used to apportion sulfur oxides at Meadview and other sampling sites throughout the study region for August 31-September 2, 1992. The results indicate that the contribution of MPP to sulfate at Meadview was typical. However, the transport of SOx from northwestern Mexico was elevated throughout much of the region during this time period. This led to the large increase in sulfate concentrations at Meadview on September 1 and 2. These results indicate that emissions from Mexico can be a significant source of particulate material in the Grand Canyon.
Collapse
|
40
|
Pope CA, Eatough DJ, Gold DR, Pang Y, Nielsen KR, Nath P, Verrier RL, Kanner RE. Acute exposure to environmental tobacco smoke and heart rate variability. ENVIRONMENTAL HEALTH PERSPECTIVES 2001; 109:711-6. [PMID: 11485870 PMCID: PMC1240375 DOI: 10.1289/ehp.01109711] [Citation(s) in RCA: 94] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Environmental tobacco smoke (ETS) has been associated with cardiovascular mortality. Pathophysiologic pathways leading from ETS exposure to cardiopulmonary disease are still being explored. Reduced cardiac autonomic function, as measured by heart rate variability (HRV), has been associated with cardiac vulnerability and may represent an important pathophysiologic mechanism linking ETS and risk of cardiac mortality. In this study we evaluated acute ETS exposure in a commercial airport with changes in HRV in 16 adult nonsmokers. We conducted ambulatory electrocardiographic (ECG) monitoring for 8-hr periods while participants alternated 2 hr in nonsmoking and smoking areas. Nicotine and respirable suspended particle concentrations and participants' blood oxygen saturation were also monitored. We calculated time and frequency domain measures of HRV for periods in and out of the smoking area, and we evaluated associations with ETS using comparative statistics and regression modeling. ETS exposure was negatively associated with all measures of HRV. During exposure periods, we observed an average decrement of approximately 12% in the standard deviation of all normal-to-normal heart beat intervals (an estimate of overall HRV). ETS exposures were not associated with mean heart rate or blood oxygen saturation. Altered cardiac autonomic function, assessed by decrements in HRV, is associated with acute exposure to ETS and may be part of the pathophysiologic mechanisms linking ETS exposure and increased cardiac vulnerability.
Collapse
|
41
|
Pang Y, Ren Y, Obeidi F, Hastings R, Eatough DJ, Wilson WE. Semi-volatile species in PM 2.5: comparison of integrated and continuous samplers for PM 2.5 research or monitoring. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION (1995) 2001; 51:25-36. [PMID: 11218422 DOI: 10.1080/10473289.2001.10464252] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Fine particles in urban atmospheres contain substantial quantities of semi-volatile material [e.g., NH4NO3 and semi-volatile organic compounds (SVOCs)] that are lost from particles during collection on a filter. Several diffusion denuder samplers have been developed for the determination of both NO3- and organic semi-volatile fine particulate components. The combination of technology used in the BOSS diffusion denuder sampler and the Harvard particle concentrator has resulted in the Particle Concentrator-Brigham Young University Organic Sampling System (PC-BOSS) for the 24-hr (or less) integrated collection of PM2.5, including NH4NO3 and semi-volatile organic material. Modification of the BOSS sampler allows for the weekly determination of these same species. Combination of BOSS denuder and tapered element oscillating microbalance (TEOM) monitor technology has resulted in the real-time ambient mass sampler (RAMS) for the continuous measurement of PM2.5, including the semi-volatile components. Comparison of the results obtained with the BOSS and with each of the newly developed modifications of the BOSS indicates that the modified versions can be used for the continuous, daily, or weekly monitoring of PM2.5, including semi-volatile species, as appropriate to the design of each sampler.
Collapse
|
42
|
Eatough DJ, Grant LD. Welcome to a Special Issue from the Specialty Conference on PM2000: Particulate Matter and Health-The Scientific Basis for Regulatory Decision-Making. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION (1995) 2000; 50:1286. [PMID: 28086061 DOI: 10.1080/10473289.2000.10464177] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
|
43
|
Eatough DJ, Farber RJ, Watson JG. Second generation chemical mass balance source apportionment of sulfur oxides and sulfate at the Grand Canyon during the Project MOHAVE summer intensive. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION (1995) 2000; 50:759-774. [PMID: 10842940 DOI: 10.1080/10473289.2000.10464113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Receptor-based chemical mass balance (CMB) analysis techniques are designed to apportion species that are conserved during pollutant transport using conserved source profiles. The techniques will fail if non-conservative species (or profiles) are not properly accounted for in the CMB model. The straightforward application of the CMB model developed for Project MOHAVE using regional profiles resulted in a significant under-prediction of total sulfate oxides (SOx, SO2 plus fine particulate sulfate) for many samples at Meadview, AZ. In addition, for these samples the concentration of the inert tracer emitted from the MOHAVE Power Project (MPP), ocPDCH, was also under-predicted. A second-generation model has been developed which assumes that separation of particles and SO2 can occur in the MPP plume during nighttime stable plume conditions. This second-generation CMB model accounts for all SOx present at the various receptor sites. In addition, the concentrations of ocPDCH and the presence of other inert tracers of emission from regional sources are accurately predicted. The major source of SOx at Meadview was the MPP, but the major source of sulfate at this site was the Las Vegas urban area. At Hopi Point in the Grand Canyon, the Baja California region (Imperial Valley and northwestern Mexico) was the major source of both SOx and sulfate.
Collapse
|
44
|
Patterson E, Eatough DJ. Indoor/outdoor relationships for ambient PM2.5 and associated pollutants: epidemiological implications in Lindon, Utah. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION (1995) 2000; 50:103-110. [PMID: 10680370 DOI: 10.1080/10473289.2000.10463986] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Outdoor and indoor fine particulate species were measured at the Lindon Elementary School in Lindon, Utah, to determine which components of ambient fine particles have strong indoor and outdoor concentration correlations. PM2.5 mass concentrations were measured using tapered element oscillating microbalance (TEOM) monitors and by gravimetric analysis of Teflon filter samples. Gas-phase HNO3, sulfur dioxide, particulate nitrate, strong acid, and particulate sulfate were measured using annular denuder samplers. Soot was measured using quartz filters in filter packs. Total particulate number was measured with a condensation nucleus counter (CNC). Total particulate number and fine particulate sulfate and soot were correlated for ambient and indoor measurements. Indoor PM2.5 mass showed a low correlation with outdoor PM2.5 mass because of the influence of coarse material from student activities on indoor PM2.5. Fine particle acidity and the potentiation of biological oxidative mechanisms by iron were not correlated indoors and outdoors.
Collapse
|
45
|
Eatough DJ, Pang Y, Eatough NL. Determination of PM 2.5 Sulfate and Nitrate with a PC-BOSS Designed for Routine Sampling for Semi-Volatile Particulate Matter. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION (1995) 1999; 49:69-75. [PMID: 29073859 DOI: 10.1080/10473289.1999.10463883] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Ambient particles contain substantial quantities of material that can be lost from the particles during sample collection on a filter. These include ammonium nitrate and semi-volatile organic compounds. As a result, the concentrations of these species are often significantly in error for results obtained with a filter pack sampler. The accurate measurement of these semi-volatile fine particulate species is essential for a complete understanding of the possible causes of health effects associated with exposure to fine particles. Past organic compound diffusion denuder samplers developed by the authors (e.g., the Brigham Young University Organic Sampling System [BOSS]) are not amenable to routine field use because of the need to independently determine the gas-phase semi-volatile organic material efficiency of the denuder for each sample. This problem has been eliminated using a combined virtual impactor, particle-concentrator inlet to provide a concentrated stream of 0.1-2.5-μm particles. This is followed by a BOSS diffusion denuder and filter packs to collect particles, including any semi-volatile species lost from the particles during sampling. The samp ler (Particle Concentrator-Brigham Young University Organic Sampling System [PC-BOSS]) contains a post-denuder multifilter pack unit to allow for the routine collection of several sequential samples. The PC-BOSS can be used for the determination of both fine particulate nitrate and semi-volatile organic material without significant "positive" or "negative" sampling artifacts. Validation of the sampler for the determination of PM2.5 sulfate and nitrate based on comparison of results obtained at Riverside, CA with collocated PC-BOSS, annular denuder, and Chem Spec samplers indicates the PC-BOSS gives accurate results for these species with a precision of ±5-8%. An average of 33% of the PM2.5 nitrate was lost from the particles during sampling for both denuder and single filter samplers.
Collapse
|
46
|
Cui W, Eatough DJ, Eatough NL. Fine particulate organic material in the Los Angeles Basin-I: assessment of the high-volume Brigham Young University organic sampling system, BIG BOSS. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION (1995) 1998; 48:1024-1037. [PMID: 9846127 DOI: 10.1080/10473289.1998.10463760] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
A multi-system, high-volume, parallel plate diffusion denuder Brigham Young University Organic Sampling System (BIG BOSS) was tested using collocated samplers at the Pico Rivera Monitoring Station of the South Coast Air Quality Management District, South Coast Air Basin, in September 1994. Six-hr daytime and 9-hr nighttime samples were collected with a flow of about 200 L/min through each of the three systems designed to collect particles smaller than 2.5, 0.8, and 0.4 microns in a diffusion denuder sampler. Efficiency for the removal of gas phase organic compounds by the diffusion denuder was evaluated using both theoretical predictions and field measurements. Both measured and calculated data indicate high denuder efficiency for the removal of gas phase aromatic and paraffinic compounds. The precision of the BIG BOSS was evaluated using collocated samplers. The precision of determination of total carbon and elemental carbon retained by a quartz filter or of semi-volatile carbonaceous material lost from particles during sampling averaged +/- 7%. The precision of determination of individual organic compounds averaged +/- 10%. An average of 42 and 62% of the particulate organic material was semi-volatile organic compounds (SVOCs) lost from particles during sampling for daytime and nighttime samples, respectively. This "negative" sampling artifact was an order of magnitude larger than the "positive" quartz filter artifact due to adsorption of gas phase organic material. Daytime concentrations of fine particulate elemental carbon and nonvolatile organic carbon were higher than nighttime concentrations, but nighttime fine particles contained more semi-volatile organic material than daytime.
Collapse
|
47
|
Ding Y, Cui W, Cui W, Eatough DJ. Fine ParticulateN–Nitroso and Nitrite Organic Compounds in the Atmosphere. ACTA ACUST UNITED AC 1998. [DOI: 10.1080/1047322x.1998.10389568] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
48
|
Eatough NL, Eatough M, Joseph JM, Caka FM, Lewis L, Eatough DJ. Precision and Accuracy in the Determination of Sulfur Oxides, Fluoride, and Spherical Aluminosilicate Fly Ash Particles in Project MOHAVE. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION (1995) 1997; 47:455-467. [PMID: 28065152 DOI: 10.1080/10473289.1997.10464414] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
The precision and accuracy of the determination of particulate sulfate and fluoride, and gas phase S02 and HF are estimated from the results obtained from collocated replicate samples and from collocated comparison samples for highland low-volume filter pack and annular diffusion denuder samplers. The results of replicate analysis of collocated samples and replicate analyses of a given sample for the determination of spherical aluminosilicate fly ash particles have also been compared. Each of these species is being used in the chemical mass balance source apportionment of sulfur oxides in the Grand Canyon region as part of Project MOHAVE, and the precision and accuracy analyses given in this paper provide input to that analysis. The precision of the various measurements reported here is ±1.8 nmol/m3 and ±2.5 nmol/m3 for the determination of S02 and sulfate, respectively, with an annular denuder. The precision is ±0.5 nmol/m3 and ±2.0 nmol/m3 for the determination of the same species with a high-volume or low-volume filter pack. The precision for the determination of the sum of HF(g) and fine particulate fluoride is +0.3 nmol/m3. The precision for the determination of aluminosilicate fly ash particles is ±100 particles/m3. At high concentrations of the various species, reproducibility of the various measurements is ±10% to ±14% of the measured concentration. The concentrations of sulfate determined using filter pack samplers are frequently higher than those determined using diffusion denuder sampling systems. The magnitude of the difference (e.g., 2-10 nmol sulfate/m3) is small, but important relative to the precision of the data and the concentrations of particulate sulfate present (typically 5-20 nmol sulfate/m3). The concentrations of S02(g) determined using a high-volume cascade impactor filter pack sampler are correspondingly lower than those obtained with diffusion denuder samplers. The concentrations of SOx (SOz(g) plus particulate sulfate) determined using the two samplers during Project MOHAVE at the Spirit Mountain, NV, and Hopi Point, AZ, sampling sites were in agreement. However, for samples collected at Painted Desert, AZ, and Meadview, AZ, the concentrations of SOx and S02(g) determined with a high-volume cascade impactor filter pack sampler were frequently lower than those determined using a diffusion denuder sampling system. These two sites had very low ambient relative humidity, an average of 25%. Possible causes of observed differences in the S02(g) and sulfate results obtained from different types of samplers are given.
Collapse
|
49
|
Eatough NL, Eatough M, Eatough DJ, Joseph JM, Caka FM. Precision and Accuracy in the Determination of Sulfur Oxides, Fluoride, and Spherical Aluminosilicate Fly Ash Particles in Project MOHAVE. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION (1995) 1997; 47:455-467. [PMID: 29081279 DOI: 10.1080/10473289.1997.10464440] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
The precision and accuracy of the determination of particu-late sulfate and fluoride, and gas phase SO2 and HF are estimated from the results obtained from collocated replicate samples and from collocated comparison samples for high-and low-volume filter pack and annular diffusion denuder samplers. The results of replicate analysis of collocated samples and replicate analyses of a given sample for the determination of spherical aluminosilicate fly ash particles have also been compared. Each of these species is being used in the chemical mass balance source apportionment of sulfur oxides in the Grand Canyon region as part of Project MOHAVE, and the precision and accuracy analyses given in this paper provide input to that analysis. The precision of the various measurements reported here is ±1.8 nmol/m3 and ±2.5 nmol/m3 for the determination of SO2 and sulfate, respectively, with an annular denuder. The precision is ±0.5 nmol/m3 and ±2.0 nmol/m3 for the determination of the same species with a high-volume or low-volume filter pack. The precision for the determination of the sum of HF(g) and fine particulate fluoride is ±0.3 nmol/m3. The precision for the determination of aluminosilicate fly ash particles is ±100 particles/m3. At high concentrations of the various species, reproducibility of the various measurements is ±10% to ±14% of the measured concentration. The concentrations of sulfate determined using filter pack samplers are frequently higher than those determined using diffusion denuder sampling systems. The magnitude of the difference (e.g., 2-10 nmol sulfate/m3) is small, but important relative to the precision of the data and the concentrations of particulate sul-fate present (typically 5-20 nmol sulfate/m3). The concentrations of SO2(g) determined using a high-volume cascade impactor filter pack sampler are correspondingly lower than those obtained with diffusion denuder samplers. The concentrations of SOx (SO2(g) plus particulate sulfate) determined using the two samplers during Project MOHAVE at the Spirit Mountain, NV, and Hopi Point, AZ, sampling sites were in agreement. However, for samples collected at Painted Desert, AZ, and Meadview, AZ, the concentrations of SOx and SO2(g) determined with a high-volume cascade impactor filter pack sampler were frequently lower than those determined using a diffusion denuder sampling system. These two sites had very low ambient relative humidity, an average of 25%. Possible causes of observed differences in the SO2(g) and sulfate results obtained from different types of samplers are given.
Collapse
|
50
|
Cui W, Machir J, Lewis L, Eatough DJ, Eatough NL. Fine Particulate Organic Material at Meadview During the Project MOHAVE Summer Intensive Study. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION (1995) 1997; 47:357-369. [PMID: 29081293 DOI: 10.1080/10473289.1997.10464438] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
The Brigham Young University (BYU) organic sampling system (BOSS) and the high flow rate multi-system BYU organic sampling system (BIG BOSS), which use multichannel diffusion denuder sampling techniques, were both used to collect samples of atmospheric fine particulate organic material. Both systems were used at the Meadview sampling site located at the western boundary of the Grand Canyon National Park in northwestern Arizona for the Project MOHAVE summer intensive sampling program in August 1992. The concentrations of total fine particulate carbonaceous material determined by temperature programmed volatilization for BOSS collocated replicate samples were in agreement with an uncertainty of ±14%. A comparable agreement was seen between the BOSS and BIG BOSS samples. Carbonaceous material collected by the second of two sequential quartz filters was shown to have originated from organic material lost from particles during sampling. About one-half of the fine particulate organic material was lost from particles during sample collection. These semi-volatile organic compounds lost from particles during sampling were characterized by GC/MS analysis. The concentrations of n-alkanes, n-fatty acids, n-fatty methyl esters, and phthalic acid as a function of fine particulate size were obtained for compounds both retained by and lost from particles during sampling. The possible sources of fine particulate semi-volatile organic material collected at Meadview, and the particle size distribution of fine particulate organic material, n-alkanes, n-fatty acids, and n-fatty esters are discussed.
Collapse
|