51
|
Brockbals L, Staeheli SN, Gascho D, Ebert LC, Kraemer T, Steuer AE. Time-Dependent Postmortem Redistribution of Opioids in Blood and Alternative Matrices. J Anal Toxicol 2019; 42:365-374. [PMID: 29579266 DOI: 10.1093/jat/bky017] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2018] [Accepted: 02/12/2018] [Indexed: 12/20/2022] Open
Abstract
Forensic postmortem case interpretation can be challenging, in particular due to postmortem redistribution (PMR) phenomena. Recent studies have shown that computed tomography (CT)-guided collection of biopsy samples using a robotic arm (virtobot) provides a valuable tool for systematic studies on time-dependent PMR. Utilizing this strategy, several cases involving opioid use such as methadone, fentanyl, tramadol, codeine, oxycodone and hydrocodone were evaluated for time-dependent concentration changes and potential redistribution mechanisms. Upon admission to the institute (t1), blood (femoral and right ventricle heart blood) and tissue biopsy samples (lung, kidney, liver, spleen, thigh muscle and adipose tissue) were collected utilizing CT-guided biopsy. Approximately 24 h later (t2; mean 28 ± 15 h), during the autopsy, samples from the same body regions were collected manually and in addition brain tissue, gastric content, urine and left ventricle heart blood. Analysis was conducted with liquid chromatography tandem mass spectrometry. Significant time-dependent methadone concentration increases in femoral blood (pB) indicate the occurrence of PMR, however, ultimately not relevant for forensic interpretation. The main metabolite of methadone, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), showed a less significant trend for PMR. Redistribution by passive diffusion along the muscle-to-pB concentration gradient seems likely for methadone, but not for EDDP. Results for fentanyl suggest extensive PMR. Other opioids such as tramadol, codeine, hydrocodone and oxycodone showed no consistent trend for significant PMR. Overall, CT-guided biopsy sampling proved to be a valuable tool for the investigation of PMR mechanisms.
Collapse
|
52
|
Gascho D, Heimer J, Tappero C, Schaerli S. Relevant findings on postmortem CT and postmortem MRI in hanging, ligature strangulation and manual strangulation and their additional value compared to autopsy - a systematic review. Forensic Sci Med Pathol 2019; 15:84-92. [PMID: 30627977 DOI: 10.1007/s12024-018-0070-z] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/03/2018] [Indexed: 12/25/2022]
Abstract
Several articles have described the use of postmortem computed tomography (CT) and postmortem magnetic resonance imaging (MRI) in forensic medicine. Although access to CT scanners and, particularly, access to MRI scanners, is still limited for several institutes, both modalities are being applied with increasing frequency in the forensic setting. Certainly, postmortem imaging can provide crucial information prior to autopsy, and this method has even been considered a replacement to autopsy in selected cases by some forensic institutes. However, the role of postmortem imaging has to be assessed individually according to various injury categories and causes of death. Therefore, this systematic review focuses on the role of postmortem CT and MRI in cases of hanging and ligature and manual strangulation. We assessed the most common and relevant findings on CT and MRI in cases of strangulation and compared the detectability of these findings among CT, MRI and autopsy. According to the available literature, mainly fractures of the hyoid bone or thyroid cartilage were investigated using postmortem CT. Compared to autopsy, CT demonstrated equivalent results concerning the detection of these fractures. A currently described "gas bubble sign" may even facilitate the detection of laryngeal fractures on CT. Regarding the detection of hemorrhages in the soft tissue of the neck, postmortem MRI is more suitable for the detection of this "vital sign" in strangulation. Compared to autopsy, postmortem MRI is almost equally accurate for the detection of hemorrhages in the neck. Another "vital sign", gas within the soft tissue in hanging, which is hardly detectable by conventional autopsy, can be clearly depicted by CT and MRI. The number of cases of manual and ligature strangulation that were investigated by means of postmortem CT and MRI is much smaller than the number of cases of hanging that were investigated by CT and MRI. Likewise, judicial hanging and the hangman's fracture on postmortem imaging were described in only a few cases. Based on the results of this systematic review, we discuss the additional value of CT and MRI in fatal strangulation compared to autopsy, and we reflect on where the literature is currently lacking.
Collapse
|
53
|
Heimer J, Gascho D, Fliss B, Martinez RM, Zoelch N. Detection of elevated ketone bodies by postmortem 1H-MRS in a case of fetal ketoacidosis. J Forensic Leg Med 2018; 59:16-19. [PMID: 30067991 DOI: 10.1016/j.jflm.2018.07.009] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2018] [Revised: 07/04/2018] [Accepted: 07/17/2018] [Indexed: 01/16/2023]
Abstract
We report a fetal loss following maternal ketoacidosis in a case of cryptic pregnancy. Biochemical analysis of peripheral blood revealed highly elevated levels of beta-hydroxybutyrate (BHB) in the mother (9.2 mmol/l) and the fetus (4.2 mmol/l). Fetal ketoacidosis with hypoxic-ischemic brain damage was determined to be the cause of death. 1H-MRS of the right cerebral hemisphere presented with distinctive resonances of BHB and acetone. Acetoacetate and glucose were not detected. Due to reported chronic abuse of ethanol and a period of fasting, alcoholic ketoacidosis was concluded to be the cause of the metabolic disorder. 1H-MRS is a viable examination for the postmortem detection of ketone bodies and may be a key supplement to noninvasive fetal autopsy for the diagnosis of ketoacidosis.
Collapse
|
54
|
Berger F, Niemann T, Kubik-Huch RA, Richter H, Thali MJ, Gascho D. Retained bullets in the head on computed tomography – Get the most out of iterative metal artifact reduction. Eur J Radiol 2018; 103:124-130. [DOI: 10.1016/j.ejrad.2018.04.019] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2017] [Revised: 04/17/2018] [Accepted: 04/18/2018] [Indexed: 11/25/2022]
|
55
|
Abstract
Suitcases or other containers are occasionally involved in forensic investigations. If there is a suspicion that human remains are hidden inside such a container, medico-legal examinations are required. However, these containers are occasionally locked. Forced opening of a locked suitcase or container may cause damage to its contents. Additionally, the safety of the investigator has to be considered as such containers may be booby-trapped or contain other hazardous material. An overview of the contents before opening is desirable in order to avoid the possibility of encountering a Pandora's box. In forensic medicine, an established approach to examine the inside of a body before opening at autopsy is postmortem computed tomography (CT). However, there may be a reluctance to use this approach for suitcases or containers with metallic components because of the assumption that severe metal artifacts will result in inadequate images. In this article, we present a forensic case in which a CT scan of a metallic suitcase was performed in order to examine its contents. Additionally, we performed an experimental scan of a conventional safe in order to determine if CT is able to reveal the contents of such a highly radiopaque storage box.
Collapse
|
56
|
Schulze K, Ebert LC, Ruder TD, Fliss B, Poschmann SA, Gascho D, Thali MJ, Flach PM. The gas bubble sign-a reliable indicator of laryngeal fractures in hanging on post-mortem CT. Br J Radiol 2018; 91:20170479. [PMID: 29327945 DOI: 10.1259/bjr.20170479] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
OBJECTIVE The purpose was to evaluate the presence of gas in the tissue adjacent to the laryngeal structures, "the gas bubble sign", in cases of hanging as a diagnostic indicator of neck trauma. METHODS In this study, post-mortem CT (PMCT) scans and autopsies of 35 victims of hanging were examined to reveal age-dependent changes, laryngeal fracture, fracture location and the presence of gas. A matched group with cardiac arrest or intoxication was used as controls (n = 35). An autopsy was performed in each case. RESULTS Incomplete suspension was the most common method in hanging. The thyroid horns (90.5%) were identified as the most vulnerable location for fractures. Laryngeal deformity and dislocation, which was only detected on PMCT, was observed in 57.1% and was concomitant with fractures in 83.3%. Laryngeal fractures are more common with advanced age (>40 years, 88.9%) and less common in younger subjects (<40 years, 29.4%). The gas bubble sign with regard to laryngeal fractures yielded a sensitivity of 79.2%, a positive predictive value of 95%, a specificity of 90.9%, a negative predictive value of 34.5% and an accuracy of 83%. CONCLUSION The complex evaluation of the larynx is profoundly supported by PMCT and the detection of the gas bubble sign as a diagnostic indicator of neck trauma. This relevant diagnostic finding might aid in not only post-mortem cases but also clinical cases, for patients who survive an assault to the neck. Advances in knowledge: (1) The gas bubble sign is a diagnostic indicator of neck trauma in not putrefied bodies. (2) PMCT supports evaluation of trauma to the neck in hanging tremendously. (3) The diagnostic finding of gas located at the laryngeal structures may not only aid in post-mortem cases but also clinical cases of people who survive an assault to the neck.
Collapse
|
57
|
Gascho D, Philipp H, Flach PM, Thali MJ, Kottner S. Standardized medical image registration for radiological identification of decedents based on paranasal sinuses. J Forensic Leg Med 2018; 54:96-101. [PMID: 29348074 DOI: 10.1016/j.jflm.2017.12.003] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2017] [Revised: 08/25/2017] [Accepted: 12/18/2017] [Indexed: 10/18/2022]
Abstract
Image registration software is frequently used in clinical radiology, e.g., for follow-up diagnosis. To a certain extent, the radiological identification of decedents (RadID) is comparable to a clinical follow-up diagnosis, in that two datasets from different dates are compared in terms of their anatomical characteristics (e.g., paranasal sinuses) or surgical implants. Due to the increasing use of computed tomography (CT) for head examinations in clinical radiology and the increased use of postmortem CT (PMCT) in forensic imaging, the comparison of three-dimensional (3D) clinical CT (termed as antemortem CT (AMCT) in this article) and PMCT datasets for RadID is becoming increasingly practical. In particular, the comparison of paranasal sinuses in AMCT and PMCT imaging is considered a suitable and reliable modality for RadID. However, previous publications regarding RadID based on comparisons of 3D datasets have not considered the implementation of image registration to provide software-side support for RadID. This article demonstrates and evaluates the use of a standard medical image registration procedure for RadID by comparing paranasal sinuses.
Collapse
|
58
|
Gascho D, Thali MJ, Niemann T. Post-mortem computed tomography: Technical principles and recommended parameter settings for high-resolution imaging. MEDICINE, SCIENCE, AND THE LAW 2018; 58:70-82. [PMID: 29310502 DOI: 10.1177/0025802417747167] [Citation(s) in RCA: 48] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Post-mortem computed tomography (PMCT) has become a standard procedure in many forensic institutes worldwide. However, the standard scan protocols offered by vendors are optimised for clinical radiology and its main considerations regarding computed tomography (CT), namely, radiation exposure and motion artefacts. Thus, these protocols aim at low-dose imaging and fast imaging techniques. However, these considerations are negligible in post-mortem imaging, which allows for significantly increased image quality. Therefore, the parameters have to be adjusted to achieve the best image quality. Several parameters affect the image quality differently and have to be weighed against each other to achieve the best image quality for different diagnostic interests. There are two main groups of parameters that are adjustable by the user: acquisition parameters and reconstruction parameters. Acquisition parameters have to be selected prior to scanning and affect the raw data composition. In contrast, reconstruction parameters affect the calculation of the slice stacks from the raw data. This article describes the CT principles from acquiring image data to post-processing and provides an overview of the significant parameters for increasing the image quality in PMCT. Based on the CT principles, the effects of these parameters on the contrast, noise, resolution and frequently occurring artefacts are described. This article provides a guide for the performance of PMCT in morgues, clinical facilities or private practices.
Collapse
|
59
|
Meichtry C, Glauser U, Glardon M, Ross SG, Lechner I, Kneubuehl BP, Gascho D, Spadavecchia C, von Rotz A, Stojiljkovic A, Stoffel MH. Assessment of a specifically developed bullet casing gun for the stunning of water buffaloes. Meat Sci 2018; 135:74-78. [DOI: 10.1016/j.meatsci.2017.09.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2017] [Revised: 07/30/2017] [Accepted: 09/13/2017] [Indexed: 10/18/2022]
|
60
|
Gascho D, Ganzoni L, Kolly P, Zoelch N, Hatch GM, Thali MJ, Ruder TD. A new method for estimating patient body weight using CT dose modulation data. Eur Radiol Exp 2017; 1:23. [PMID: 29708203 PMCID: PMC5909357 DOI: 10.1186/s41747-017-0028-z] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2017] [Accepted: 10/20/2017] [Indexed: 01/04/2023] Open
Abstract
Background Body weight (BW) is a relevant metric in emergency care. However, visual/physical methods to estimate BW are unreliable. We have developed a method for estimating BW based on effective mAs (mAseff) from computed tomography (CT) dose modulation. Methods The mAseff of CT examinations was correlated with the BW of 329 decedents. Linear regression analysis was used to calculate an equation for BW estimation based on the results of decedents with a postmortem interval (PMI) < 4 days (n = 240). The equation was applied to a validation group of 125 decedents. Pearson correlation and t-test statistics were used. Results We found an overall strong correlation between mAseff and BW (r = 0.931); r values ranged from 0.854 for decedents with PMI ≥ 4 days to 0.966 for those with PMI < 4 days; among the latter group, r was 0.974 for females and 0.960 for males and 0.969 in the presence and 0.966 in the absence of metallic implants (all correlations with p values < 0.001). The estimated BW was equal to 3.732 + (0.422 × mAseff) – (3.108 × sex index), where the sex index is 0 for males and 1 for females. The validation group showed a strong correlation (r = 0.969) between measured BW and the predicted BW, without significant differences overall (p = 0.119) as well as in female (p = 0.394) and in male decedents (p = 0.196). No outliers were observed. Conclusions CT dose modulation is a rapid and reliable method for BW estimation with potential use in clinical practice, in particular in emergency settings.
Collapse
|
61
|
Heimer J, Gascho D, Chatzaraki V, Knaute DF, Sterzik V, Martinez RM, Thali MJ, Zoelch N. Postmortem 1H-MRS—Detection of Ketone Bodies and Glucose in Diabetic Ketoacidosis. Int J Legal Med 2017; 132:593-598. [DOI: 10.1007/s00414-017-1741-0] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2017] [Accepted: 11/13/2017] [Indexed: 12/15/2022]
|
62
|
Geiger M, Evin A, Sánchez-Villagra MR, Gascho D, Mainini C, Zollikofer CPE. Neomorphosis and heterochrony of skull shape in dog domestication. Sci Rep 2017; 7:13443. [PMID: 29044203 PMCID: PMC5647425 DOI: 10.1038/s41598-017-12582-2] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2017] [Accepted: 09/08/2017] [Indexed: 01/08/2023] Open
Abstract
The overall similarity of the skull shape of some dog breeds with that of juvenile wolves begs the question if and how ontogenetic changes such as paedomorphosis (evolutionary juvenilisation) played a role in domestication. Here we test for changes in patterns of development and growth during dog domestication. We present the first geometric morphometric study using ontogenetic series of dog and wolf crania, and samples of dogs with relatively ancestral morphology and from different time periods. We show that patterns of juvenile-to-adult morphological change are largely similar in wolves and domestic dogs, but differ in two ways. First, dog skulls show unique (neomorphic) features already shortly after birth, and these features persist throughout postnatal ontogeny. Second, at any given age, juvenile dogs exhibit skull shapes that resemble those of consistently younger wolves, even in dog breeds that do not exhibit a 'juvenilized' morphology as adults. These patterns exemplify the complex nature of evolutionary changes during dog domestication: the cranial morphology of adult dogs cannot simply be explained as either neomorphic or paedomorphic. The key to our understanding of dog domestication may lie in a closer comparative examination of developmental phases.
Collapse
|
63
|
Grob K, Manestar M, Gascho D, Ackland T, Gilbey H, Fretz C, Kuster MS. Magnetic resonance imaging of the tensor vastus intermedius: A topographic study based on anatomical dissections. Clin Anat 2017; 30:1096-1102. [DOI: 10.1002/ca.22981] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2017] [Revised: 08/10/2017] [Accepted: 08/11/2017] [Indexed: 11/11/2022]
|
64
|
Brun CN, Christensen AM, Kravarski M, Gorincour G, Schweitzer W, Thali MJ, Gascho D, Hatch GM, Ruder TD. Comparative radiologic identification with standardized single CT images of the paranasal sinuses-Evaluation of inter-rater reliability. Forensic Sci Int 2017; 280:81-86. [PMID: 28961444 DOI: 10.1016/j.forsciint.2017.08.029] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2016] [Revised: 04/11/2017] [Accepted: 08/28/2017] [Indexed: 11/30/2022]
Abstract
The aim of this study was to assess the reproducibility of a standardized image for personal identification (SIPI), used in the comparative analysis of paranasal sinuses, and test the effect of inaccurate reformation of the SIPI on suitability for comparative identification. Five raters with different professional backgrounds independently reformatted SIPIs from ten post-mortem head CTs. Inter-rater, intra-rater agreement as well angular deviations between reformatted SIPI images and reference SIPI images were calculated. Second, raters assessed the suitability of 70 accurately and inaccurately reformatted SIPIs for identification with a 4-point Likert scale. Inter-rater agreement as well as levels of significance regarding image suitability were calculated. Inter-rater agreement regarding reproducibility of SIPI reformation was excellent (inter-rater correlation coefficient (ICC) 0.9995, intra-rater ICC 0.9983). Deviation between the angular dimensions of the reformatted SIPIs and the reference SIPIs was ≤1° in 94% of all 300 measurements. Inter-rater agreement regarding the effect of inaccurate SIPI reformation on suitability for comparative identification was fair (ICC 0.6809). There was no statistically significant difference between raters' evaluation of image suitability (p=0.9755). This study shows that the standardized image for personal identification can be accurately reformatted by different raters with varying professional backgrounds. In addition, raters agree that inaccurately reformatted SIPIs are still suitable for comparative identification in the majority of cases.
Collapse
|
65
|
Staeheli SN, Boxler MI, Oestreich A, Marti M, Gascho D, Bolliger SA, Kraemer T, Steuer AE. Postmortem distribution and redistribution of MDAI and 2-MAPB in blood and alternative matrices. Forensic Sci Int 2017; 279:83-87. [PMID: 28850871 DOI: 10.1016/j.forsciint.2017.08.007] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2017] [Revised: 07/27/2017] [Accepted: 08/07/2017] [Indexed: 11/29/2022]
Abstract
Intoxication cases involving new psychoactive substances (NPS) provide several challenges for forensic toxicologists as data on pharmacodynamic and pharmacokinetic properties are lacking, especially on potency and toxicity. Furthermore, reference values and information on postmortem redistribution (PMR) do not exist so far for most NPS. A fatal case involving the amphetamine-derivatives MDAI (5,6-methylenedioxy-2-aminoindane) and 2-MAPB (1-(benzofuran-2-yl)-N-methylpropan-2-amine) was investigated at the Zurich Institute of Forensic Medicine. At admission at the institute approx. 11h after death (first time point, t1), femoral and heart blood (right ventricle) was collected using computed tomography (CT)-guided biopsy sampling. At autopsy (t2), samples from the same body regions as well as various tissue samples were collected manually. In addition, an antemortem blood sample collected 6h before death was available. MDAI and 2-MAPB were quantified using a validated LC-MS/MS method. A significant concentration decrease between the antemortem and the first peripheral postmortem blood sample was observed, which most probably can be explained by remaining metabolism and excretion within the last 6h prior to death. No significant concentration change was observed between the two postmortem heart blood and peripheral blood samples. Accordingly, MDAI and 2-MAPB did not seem to undergo relevant postmortem redistribution in peripheral and heart blood in the presented case. This is the first study on postmortem redistribution of the new psychoactive substances MDAI and 2-MAPB. However, more studies covering more cases are necessary to generate universal statements on the PMR with these two NPSs.
Collapse
|
66
|
Heimer J, Gascho D, Gentile S, Hatch GM, Thali MJ, Ruder TD. Antemortem identification by fusion of MR and CT of the paranasal sinuses. Forensic Sci Med Pathol 2017; 13:375-378. [PMID: 28526949 DOI: 10.1007/s12024-017-9873-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/13/2017] [Indexed: 10/19/2022]
Abstract
Radiologic forensic identification is usually performed by comparing antemortem and postmortem radiographs. While computed tomography (CT) has become a valuable addition to radiologic identification, magnetic resonance (MR) imaging has only rarely been used for this purpose. In our case, identification was accomplished using fused MR- and CT images in a survivor of a gunshot injury to the head. This case supports and highlights the possibility to perform intermodality radiologic identification comparing preexisting MR imaging to subsequently aquired CT data in living (or deceased) humans as long as manual modifications of windowing, color and contrast enable differentiation of the two modalities in the fused image.
Collapse
|
67
|
Gascho D, Morf NV, Thali MJ, Schaerli S. The use of immunochromatographic rapid test for soft tissue remains identification in order to distinguish between human and non-human origin. Sci Justice 2017; 57:165-168. [DOI: 10.1016/j.scijus.2017.02.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/20/2016] [Revised: 02/23/2017] [Accepted: 02/25/2017] [Indexed: 10/20/2022]
|
68
|
Sievert C, Richter H, Gascho D, Kircher PR, Carrera I. 3 Tesla magnetic resonance imaging study of the normal canine femoral and sciatic nerves. Vet Radiol Ultrasound 2017; 58:598-606. [PMID: 28444825 DOI: 10.1111/vru.12511] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2016] [Revised: 02/08/2017] [Accepted: 03/13/2017] [Indexed: 11/28/2022] Open
Abstract
Understanding the normal course and optimizing visualization of the canine peripheral nerves of the lumbar plexus, in particular the sciatic and the femoral nerves, is essential when interpreting images of patients with suspected peripheral neuropathies such as inflammatory or neoplastic conditions. The purpose of this prospective, anatomic study was to describe the magnetic resonance imaging (MRI) anatomy of the normal canine femoral and sciatic nerves and to define the sequences in which the nerves are best depicted. A preliminary postmortem cadaver study was performed to determine optimal sequences and imaging protocol. In a second step the optimized technique was implemented on 10 healthy Beagle dogs, included in the study. The applied protocol included the following sequences: T1-weighted, T2-weighted, T2-Spectral Attenuated Inversion Recovery, T1-weighted postcontrast and T1-Spectral Presaturated Inversion Recovery postcontrast. All sequences had satisfactory signal-to-noise ratio and contrast resolution in all patients. The sciatic and femoral nerves were seen in all images. They were symmetric and of homogeneous signal intensity, being iso- to mildly hyperintense to muscle on T2-weighted, mildly hyperintense in T2-Spectral Attenuated Inversion Recovery, and iso- to mildly hypointense in T1-weighted images. No evidence of contrast enhancement in T1-weighted and T1-Spectral Presaturated Inversion Recovery postcontrast sequences was observed. The anatomic landmarks helpful to identify the course of the femoral and sciatic nerves are described in detail. This study may be used as an anatomical reference, depicting the normal canine femoral and sciatic nerves at 3 Tesla MRI.
Collapse
|
69
|
Gascho D, Schaerli S, Thali MJ, Bolliger SA. Response to "regarding the sudden death of a juvenile with rare TdT-negative T-LBL/T-ALL, splenic rupture, and mediastinal mass". Forensic Sci Med Pathol 2017; 13:397-398. [PMID: 28405884 DOI: 10.1007/s12024-017-9865-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/14/2017] [Indexed: 11/28/2022]
|
70
|
Kottner S, Ebert LC, Ampanozi G, Braun M, Thali MJ, Gascho D. VirtoScan - a mobile, low-cost photogrammetry setup for fast post-mortem 3D full-body documentations in x-ray computed tomography and autopsy suites. Forensic Sci Med Pathol 2017; 13:34-43. [DOI: 10.1007/s12024-016-9837-2] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/22/2016] [Indexed: 11/24/2022]
|
71
|
Mathews S, Burkhard M, Serrano N, Link K, Häusler M, Frater N, Franke I, Bischofberger H, Buck FM, Gascho D, Thali M, Serowy S, Müller-Gerbl M, Harper G, Qureshi F, Böni T, Bloch HR, Ullrich O, Rühli FJ, Eppler E. Glenoid morphology in light of anatomical and reverse total shoulder arthroplasty: a dissection- and 3D-CT-based study in male and female body donors. BMC Musculoskelet Disord 2017; 18:9. [PMID: 28068966 PMCID: PMC5223371 DOI: 10.1186/s12891-016-1373-4] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/22/2016] [Accepted: 12/19/2016] [Indexed: 11/19/2022] Open
Abstract
Background Placement of the glenoid baseplate is of paramount importance for the outcome of anatomical and reverse total shoulder arthroplasty. However, the database around glenoid size is poor, particularly regarding small scapulae, for example, in women and smaller individuals, and is derived from different methodological approaches. In this multimodality cadaver study, we systematically examined the glenoid using morphological and 3D-CT measurements. Methods Measurements of the glenoid and drill hole tunnel length for superior baseplate screw placement were recorded to define size of the glenoid and the distance to the scapular notch on cadaveric specimens. Glenoid angles were determined on both, 3D-CT-scans of the thoraxes using the Friedman method and on subsequently isolated scapulae from 18 male and female donors (average 84 years, range 60–98 years). Results Mean glenoid height was 36.6 mm ± 3.6, and width 27.8 mm ± 3.1 with a significant sex dimorphism (p ≤ 0.001): in males, glenoid height 39.5 mm ± 3.5, and width 30.3 mm ± 3.3, and in females, glenoid height 34.8 mm ± 2.2, and width 26.2 mm ± 1.6. The average distance from the superior screw entry to its exit in the scapular notch measured by calliper was 27.2 mm ± 6.0 with a sex difference: in males, 29.4 mm ± 5.7, and in females, 25.8 mm ± 5.9 mm with a minimum recorded distance of 15 mm. Measured by CT, the mean inclination angle for male and female donors combined was 13.0° ± 7.0, and the ante-/retroversion angle −1.0° ± 4.0°. Conclusion This study is one of the first to combine dissection, including drill holes, with anatomical measurements and radiological data. In some women and smaller individuals, smaller baseplates should be selected. The published safe zone of 20 mm is generally feasible for superior screw placement, however, in small patients this distance may be substantially shorter than expected and start as of 13 and 15 mm, respectively. No correlation between glenoid height or width with the length of our drilling canal towards the scapular notch was found. Preoperative CT-based treatment planning to determine version and inclination angles is recommended.
Collapse
|
72
|
Staeheli SN, Gascho D, Ebert LC, Kraemer T, Steuer AE. Time-dependent postmortem redistribution of morphine and its metabolites in blood and alternative matrices—application of CT-guided biopsy sampling. Int J Legal Med 2016; 131:379-389. [DOI: 10.1007/s00414-016-1485-2] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2016] [Accepted: 10/20/2016] [Indexed: 11/30/2022]
|
73
|
Staeheli SN, Baumgartner MR, Gauthier S, Gascho D, Jarmer J, Kraemer T, Steuer AE. Time-dependent postmortem redistribution of butyrfentanyl and its metabolites in blood and alternative matrices in a case of butyrfentanyl intoxication. Forensic Sci Int 2016; 266:170-177. [DOI: 10.1016/j.forsciint.2016.05.034] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2016] [Revised: 05/19/2016] [Accepted: 05/27/2016] [Indexed: 11/29/2022]
|
74
|
Gascho D, Gentile S, Bolliger SA, Thali MJ. Charon’s Coins. Forensic Sci Med Pathol 2016; 12:384-7. [DOI: 10.1007/s12024-016-9794-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/30/2016] [Indexed: 12/01/2022]
|
75
|
Berger F, Steuer AE, Rentsch K, Gascho D, Stamou S, Schärli S, Thali MJ, Krämer T, Flach PM. Postmortem computed tomography and magnetic resonance imaging facilitates forensic autopsy in a fatal case of poisoning with formic acid, diphenhydramine, and ethanol. Forensic Sci Med Pathol 2016; 12:304-11. [DOI: 10.1007/s12024-016-9797-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/02/2016] [Indexed: 11/28/2022]
|
76
|
Schweitzer W, Flach PM, Thali M, Laberke P, Gascho D. Very economical immersion pump feasibility for postmortem CT angiography. ACTA ACUST UNITED AC 2016. [DOI: 10.1016/j.jofri.2015.11.009] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
77
|
Schaerli S, Berger F, Thali MJ, Gascho D. Ankh in the depth – Subdermal 3D art implants: Radiological identification with body modification. Leg Med (Tokyo) 2016; 20:12-4. [DOI: 10.1016/j.legalmed.2016.03.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2016] [Revised: 02/29/2016] [Accepted: 03/01/2016] [Indexed: 10/22/2022]
|
78
|
Schwenk BK, Lechner I, Ross SG, Gascho D, Kneubuehl BP, Glardon M, Stoffel MH. Magnetic resonance imaging and computer tomography of brain lesions in water buffaloes and cattle stunned with handguns or captive bolts. Meat Sci 2015; 113:35-40. [PMID: 26610289 DOI: 10.1016/j.meatsci.2015.11.010] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2014] [Revised: 11/03/2015] [Accepted: 11/10/2015] [Indexed: 10/22/2022]
Abstract
Owing to the demand for genuine mozzarella, some 330 water buffaloes are being slaughtered every year in Switzerland albeit a stunning procedure meeting animal welfare and occupational safety requirements remains to be established. To provide a basis for improvements, we sized anatomical specifics in water buffaloes and cattle and we assessed brain lesions after stunning with captive bolts or handguns by diagnostic imaging. In water buffaloes and cattle, the median distance from the frontal skin surface to the inner bone table was 74.0mm (56.0-100.0mm) vs 36.6mm (29.3-44.3mm) and from skin to the thalamus 144.8mm (117.1-172.0mm) vs 102.0 (101.0-121.0mm), respectively. Consequently, customary captive bolt stunners may be inadequate. Free bullets are potentially suitable for stunning buffaloes but involve occupational safety hazards. The results of the present study shall be used to develop a device allowing effective and safe stunning of water buffaloes.
Collapse
|
79
|
|
80
|
Berger N, Ebert LC, Ampanozi G, Flach PM, Gascho D, Thali MJ, Ruder TD. Smaller but denser: postmortem changes alter the CT characteristics of subdural hematomas. Forensic Sci Med Pathol 2015; 11:40-6. [PMID: 25566767 DOI: 10.1007/s12024-014-9642-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/04/2014] [Indexed: 10/24/2022]
Abstract
PURPOSE The aim of this study was to investigate if (1) the volume of subdural hematomas (SDH), midline shift, and CT density of subdural hematomas are altered by postmortem changes and (2) if these changes are dependent on the postmortem interval (PMI). MATERIALS AND METHODS Ante mortem computed tomography (AMCT) of the head was compared to corresponding postmortem CT (PMCT) in 19 adults with SDH. SDH volume, midline shift, and hematoma density were measured on both AMCT and PMCT and their differences assessed using Wilcoxon-Signed Rank Test. Spearman's Rho Test was used to assess significant correlations between the PMI and the alterations of SDH volume, midline shift, and hematoma density. RESULTS Mean time between last AMCT and PMCT was 109 h, mean PMI was 35 h. On PMCT mean midline displacement was decreased by 57% (p < 0.001); mean SDH volume was decreased by 38% (p < 0.001); and mean hematoma density was increased by 18% (p < 0.001) in comparison to AMCT. There was no correlation between the PMI and the normalization of the midline shift (p = 0.706), the reduction of SDH volume (p = 0.366), or the increase of hematoma density (p = 0.140). CONCLUSIONS This study reveals that normal postmortem changes significantly affect the extent and imaging characteristics of subdural hematoma and may therefore affect the interpretation of these findings on PMCT. Radiologists and forensic pathologists who use PMCT must be aware of these phenomena in order to correctly interpret PMCT findings in cases of subdural hemorrhages.
Collapse
|
81
|
Franckenberg S, Schulze C, Bolliger SA, Gascho D, Thali MJ, Flach PM. Postmortem angiography in computed tomography and magnetic resonance imaging in a case of fatal hemorrhage due to an arterio-venous malformation in the brain. Leg Med (Tokyo) 2014; 17:180-3. [PMID: 25572321 DOI: 10.1016/j.legalmed.2014.11.006] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2014] [Revised: 11/25/2014] [Accepted: 11/26/2014] [Indexed: 10/24/2022]
Abstract
Autopsy is the traditional gold standard for determining the cause and manner of death in a forensic death investigation. However, postmortem imaging plays an ever-growing role in preliminary examination, even replacing conventional autopsy in some cases. This case report presents a case of massive intra-axial brain hemorrhage due to an arterio-venous malformation. The cause and manner of death were exclusively determined by postmortem radiology. Based on radiological findings, the autopsy was considered redundant and cancelled by the public prosecutor.
Collapse
|
82
|
Ebner L, Flach P, Schumann K, Gascho D, Ruder T, Christe A, Thali M, Ampanozi G. The tip of the tip of the knife: Stab sequence reconstruction using postmortem CT in a homicide case. ACTA ACUST UNITED AC 2014. [DOI: 10.1016/j.jofri.2014.08.002] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
83
|
Ruder TD, Schulze K, Ross S, Ampanozi G, Gascho D, Laberke P, Thali MJ, Hatch GM. Into the decomposed body – Feasibility of post-mortem CT angiography in a decomposed cadaver. ACTA ACUST UNITED AC 2014. [DOI: 10.1016/j.jofri.2014.05.007] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
84
|
Flach PM, Gascho D, Schweitzer W, Ruder TD, Berger N, Ross SG, Thali MJ, Ampanozi G. Imaging in forensic radiology: an illustrated guide for postmortem computed tomography technique and protocols. Forensic Sci Med Pathol 2014; 10:583-606. [DOI: 10.1007/s12024-014-9555-6] [Citation(s) in RCA: 131] [Impact Index Per Article: 13.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/10/2014] [Indexed: 11/30/2022]
|
85
|
Berger N, Paula P, Gascho D, Flach PM, Thali MJ, Ross SG, Ampanozi G. Bone marrow edema induced by a bullet after a self-inflicted accidental firing. Leg Med (Tokyo) 2013; 15:329-31. [DOI: 10.1016/j.legalmed.2013.09.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2013] [Revised: 09/09/2013] [Accepted: 09/10/2013] [Indexed: 11/26/2022]
|
86
|
Berger N, Ross SG, Ampanozi G, Majcen R, Schweitzer W, Gascho D, Thali MJ, Flach PM. Puzzling over intracranial gas: Disclosing a pitfall on postmortem computed tomography in a case of fatal blunt trauma. ACTA ACUST UNITED AC 2013. [DOI: 10.1016/j.jofri.2013.05.012] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
87
|
Kluschke F, Ross S, Flach PM, Schweitzer W, Ampanozi G, Gascho D, Vonlanthen B, Thali MJ, Ruder TD. To see or not to see -- ambiguous findings on post-mortem cross-sectional imaging in a case of ruptured abdominal aortic aneurysm. Leg Med (Tokyo) 2013; 15:256-9. [PMID: 23602209 DOI: 10.1016/j.legalmed.2013.03.001] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2013] [Revised: 02/28/2013] [Accepted: 03/02/2013] [Indexed: 11/27/2022]
Abstract
We present a case of a ruptured abdominal aortic aneurysm (AAA) with ambiguous accessory findings on post-mortem computed-tomography (PMCT), post-mortem magnetic resonance (PMMR) imaging, and PMCT-angiography (PMCTA) suggestive of thoracic aortic dissection. The diagnosis of ruptured AAA was confirmed by autopsy; however, there was no aortic dissection. The imaging findings that mimicked the presence of aortic dissection might have been an atypical presentation of post-mortem clotting or sedimentation. This case is an ideal example to illustrate benefits, limitations, and challenges of post-mortem cross-sectional imaging. It serves as a reminder that both, training as well as correlation of imaging findings with autopsy are fundamental to improve our understanding of radiologic findings on post-mortem cross-sectional imaging.
Collapse
|