26
|
Mahnken AH, Klotz E, Chefdhotel C, Schreiber S, Wildberger J, Günther RW. Farbcodierte Analyse des hepatischen Perfusionsindex zur Vorhersage von Tumorrezidiven nach Radiofrequenzablation. ROFO-FORTSCHR RONTG 2010. [DOI: 10.1055/s-0030-1252698] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
27
|
Schramm P, Xyda A, Bock C, Schramm R, Klotz E, Knauth M. 4D-Volumen-Perfusionscomputertomographie von intraaxialen Tumoren. ROFO-FORTSCHR RONTG 2010. [DOI: 10.1055/s-0030-1252807] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
28
|
Klotz E, Seelentag W. Untersuchungen zur Belastung der Keimdrüsen durch Hartstrahldiagnostik*. ROFO-FORTSCHR RONTG 2009. [DOI: 10.1055/s-0029-1226129] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
29
|
Ewald P, Klotz E. Arterielle Durchblutungsstörung des Armes als Spätfolge nach Klavikulafraktur. ROFO-FORTSCHR RONTG 2009. [DOI: 10.1055/s-0029-1229464] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
30
|
Helck A, Klotz E, Sommer WH, Reiser MF, Becker CR. Messung der glomerulären Filtrationsrate mithilfe der zeitaufgelösten Nieren-CT-Angiographie – gleichzeitige Erfassung von Funktion und Morphologie. ROFO-FORTSCHR RONTG 2009. [DOI: 10.1055/s-0029-1221447] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
31
|
Birnbaum J, Klotz E, Spies CD, Mueller J, Vargas Hein O, Feller J, Lehmann C. Impact of combined C1 esterase inhibitor/coagulation factor XIII or N-acetylcysteine/tirilazad mesylate administration on leucocyte adherence and cytokine release in experimental endotoxaemia. J Int Med Res 2008; 36:748-59. [PMID: 18652771 DOI: 10.1177/147323000803600417] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
We determined the effects of combinations of C1 esterase inhibitor (C1-INH) with factor XIII and of N-acetylcysteine (NAC) with tirilazad mesylate (TM) during lipo-polysaccharide (LPS)-induced endotoxaemia in rats. Forty Wistar rats were divided into four groups: the control (CON) group received no LPS; the LPS, C1-INH + factor XIII and NAC + TM groups received endotoxin infusions (5 mg/kg per h). After 30 min of endotoxaemia, 100 U/kg C1-INH + 50 U/kg factor XIII was administered to the C1-INH + factor XIII group, and 150 mg/kg NAC + 10 mg/kg TM was administered in the NAC + TM group. Administration of C1-INH + factor XIII and NAC + TM both resulted in reduced leucocyte adherence and reduced levels of interleukin-1beta (IL-1beta). The LPS-induced increase in IL-6 levels was amplified by both drug combinations. There was no significant effect on mesenteric plasma extravasation. In conclusion, the administration of C1-INH + factor XIII and NAC + TM reduced endothelial leucocyte adherence and IL-1beta plasma levels, but increased IL-6 levels.
Collapse
|
32
|
Birnbaum J, Klotz E, Bogusch G, Volk T. [Electrical nerve stimulation for plexus and nerve blocks]. Anaesthesist 2008; 56:1155-62. [PMID: 17896093 DOI: 10.1007/s00101-007-1238-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Despite the increasing use of ultrasound, electrical nerve stimulation is commonly used as the standard for both plexus and peripheral nerve blocks. Several recent randomized trials have contributed to a better understanding of physiological and clinical correlations. Traditionally used currents and impulse widths are better defined in relation to the distance between needle tip and nerves. Commercially available devices enable transcutaneous nerve stimulation and provide new opportunities for the detection of puncture sites and for training. The electrically ideal position of the needle usually is defined by motor responses which can not be interpreted without profound anatomical knowledge. For instance, interscalene blocks can be successful even after motor responses of deltoid or pectoral muscles. Infraclavicular blocks should be aimed at stimulation of the posterior fascicle (extension). In contrast to multiple single nerve blocks, axillary single-shot blocks more commonly result in incomplete anaesthesia. Blockade of the femoral nerve can be performed without any nerve stimulation if the fascia iliaca block is used. Independently of the various approaches to the sciatic nerve, inversion and plantar flexion are the best options for single-shot blocks. Further clinical trials are needed to define the advantages of stimulating catheters in continuous nerve blocks.
Collapse
|
33
|
Birnbaum J, Lehmann C, Klotz E, Hein OV, Blume A, Jubin F, Polze N, Luther D, Spies CD. Effects of N-acetylcysteine and tirilazad mesylate on intestinal functional capillary density, leukocyte adherence, mesenteric plasma extravasation and cytokine levels in experimental endotoxemia in rats. Clin Hemorheol Microcirc 2008; 39:99-111. [PMID: 18503116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
INTRODUCTION The study's objective was to determine the effects of the administration of N-acetylcysteine (NAC) and of tirilazad mesylate (TM) on intestinal functional capillary density, mesenteric plasma extravasation, leukocyte adherence and on cytokine release during experimental endotoxemia in rats. METHODS In a prospective, randomized, controlled animal study, 80 male Wistar rats were examined in 2 test series. Both series were divided into 4 groups. Group 1 served as control group (CON group). Group 2 (LPS group), group 3 (NAC group) and group 4 (TM group) received endotoxin infusions (10 mg/kg over 2 h). In NAC group 150 mg/kg body weight NAC was administered after the first 30 minutes of endotoxemia intravenously. In TM group, 10 mg/kg body weight TM was administered after the first 30 minutes of endotoxemia intravenously. Animals of the series 1 underwent studies of leukocyte adherence on submucosal venular endothelium of the small bowel wall and intestinal functional capillary density (FCD) in the intestinal mucosa and the circular as well as the longitudinal muscle layer by intravital fluorescence microscopy (IVM). Plasma levels of interleukin 1beta (IL-1beta), interferone gamma (IFN-gamma) and soluble intercellular adhesion molecule1 (s-ICAM 1) as well as white blood cell count (WBC) were estimated. In the animals of the series 2 mesenteric plasma extravasation was determined by IVM and plasma levels of tumor necrosis factor alpha (TNF-alpha), IL-4, IL-6, IL-10 and malondialdehyde (MDA) were estimated. RESULTS After LPS administration, FCD in the villi intestinales was unchanged and in the longitudinal muscularis layer it was increased. There was no effect of NAC or TM administration on FCD.Although the plasma extravasation was not significantly influenced by LPS administration, TM administration resulted in a lower plasma extravasation in the TM group compared to the other groups. After endotoxin challenge, the firmly adherence of leukocytes to vascular endothelium as a parameter of leukocyte activation in endotoxemia was increased but NAC or TM administration had no influence on leukocyte adherence. The plasma levels of IL-1beta, IL-6, IL-10, TNF-alpha, IFN-gamma and sICAM-1 were increased in the endotoxemic groups (LPS group, NAC group and TM group) and the WBC was decreased compared to controls. IL-4 levels were unchanged during observation period. Plasma MDA levels were not influenced by LPS administration compared to controls. The administration of NAC resulted in lower sICAM-1 and MDA levels compared to the LPS group. The IL-1beta, IL-6, IL-10, TNF-alpha and IFN-gamma plasma levels were not influenced by NAC or TM administration. CONCLUSIONS In this posttreatment sepsis model in rats, NAC administration resulted in lower sICAM-1 and MDA levels compared to the LPS treated animals. TM administration reduced the plasma extravasation in this model.
Collapse
|
34
|
Birnbaum J, Lehmann C, Klotz E, Hein OV, Blume A, Jubin F, Polze N, Luther D, Spies C. Effects of N-acetylcysteine and tirilazad mesylate on intestinal functional capillary density, leukocyte adherence, mesenteric plasma extravasation and cytokine levels in experimental endotoxemia in rats. Clin Hemorheol Microcirc 2008. [DOI: 10.3233/ch-2008-1073] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
35
|
Carmoi T, Verret C, Debonne JM, Klotz E. [Management of type 2 diabetes in subsaharan Africa: update and perspective]. MEDECINE TROPICALE : REVUE DU CORPS DE SANTE COLONIAL 2007; 67:601-606. [PMID: 18300523] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Management of type II diabetes in sub-Saharan Africa presents a number of aspects that must be analyzed successively. Regarding the continent of Africa, implementing a strategy to control diabetes will require extensive information and education campaigns not only for health care workers but also for the general population as well as the creation of adequate infrastructure to optimize the availability of treatment. Regarding care modalities in Africa, the overall principles of management are the same as anywhere in the world. However these modalities must be adapted to the sociocultural environment of the patient. Objectives must be simplified without compromising the scientific requirements. Regarding patients, African perceptions about the disease are very different from those taught in Western schools. The different ethnocultural components of the disease must be recognized in order to optimize overall patient management.
Collapse
|
36
|
Lell MM, Ditt H, Panknin C, Sayre JW, Ruehm SG, Klotz E, Tomandl BF, Villablanca JP. Bone-subtraction CT angiography: evaluation of two different fully automated image-registration procedures for interscan motion compensation. AJNR Am J Neuroradiol 2007; 28:1362-8. [PMID: 17698541 PMCID: PMC7977676 DOI: 10.3174/ajnr.a0558] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Bone-subtraction techniques have been shown to enhance CT angiography (CTA) interpretation, but motion can lead to incomplete bone removal. The aim of this study was to evaluate 2 novel registration techniques to compensate for patient motion. MATERIALS AND METHODS Fifty-four patients underwent bone-subtraction CTA (BSCTA) for the evaluation of the neck vessels with 64-section CT. We tested 3 different registration procedures: pure rigid registration (BSCTA), slab-based registration (SB-BSCTA), and a partially rigid registration (PR-BSCTA) approach. Subtraction quality for the assessment of different vascular segments was evaluated by 2 examiners in a blinded fashion. The Cohen kappa test was applied for interobserver variability, and the Wilcoxon signed rank test, for differences between the procedures. Motion between the corresponding datasets was measured and plotted against image-quality scores. RESULTS Algorithms with motion compensation revealed higher image-quality scores (SB-BSCTA, mean 4.31; PR-BSCTA, mean 4.43) than pure rigid registration (BSCTA, mean 3.88). PR-BSCTA was rated superior to SB-BSCTA for the evaluation of the cervical internal and external carotid arteries (P<.001), whereas there was no significant difference for the other vessels (P=.157-.655). Both algorithms were clearly superior to pure rigid registration for all vessels except the basilar and ophthalmic artery. Interobserver agreement was high (kappa=0.46-0.98). CONCLUSION Bone-subtraction algorithms with motion compensation provided higher image-quality scores than pure rigid registration methods, especially in cases with complex motion. PR-BSCTA was rated superior to SB-BSCTA in the visualization of the internal and external carotid arteries.
Collapse
|
37
|
Lell M, Anders K, Klotz E, Ditt H, Bautz W, Tomandi B. Clinical evaluation of bone-subtraction CT angiography (BSCTA) in head and neck imaging. Clin Imaging 2006. [DOI: 10.1016/j.clinimag.2006.05.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
38
|
Ebara M, Murayama Y, Saguchi T, Ishibashi T, Irie K, Takao H, Sadaoka S, Klotz E, Abe T. Balloon Test Occlusion with Perfusion CT Imaging Utilizing Intraarterial Contrast Injection. Interv Neuroradiol 2006; 12:241-5. [PMID: 20569640 DOI: 10.1177/15910199060120s144] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2005] [Accepted: 12/15/2005] [Indexed: 11/16/2022] Open
Abstract
SUMMARY Balloon Test Occlusion (BTO) is performed to evaluate the collateral flow when a permanent therapeutic occlusion of unilateral carotid artery is planned. BTO with neurological evaluation alone, however, has a rather high false negative rate. In order to improve the sensitivity, several adjunctive procedures such as induced hypotension or cerebral blood flow (CBF) measurement with various modalities have been combined. Perfusion CT (PCT) is another imaging modality that is mainly used for the diagnosis of acute stroke. In this study, we evaluate the efficacy and the safety of BTO combined with PCT in the same procedure utilizing intraarterial contrast injection from the catheter. Seven patients underwent BTO with PCT in our institution. All the procedures were performed in the angio/CT combination suite. BTO was performed in the usual fashion and when the patient passed the 30 minutes' BTO clinically, PCT was performed subsequently. Contrast material was injected from a Pig Tail catheter placed in the ascending aorta. The obtained data were transferred to a workstation and perfusion maps of CBF, cerebral blood volume (CBV), and time to peak (TTP) were generated using software. In three patients, single photon emission CT (SPECT) was also obtained with administering 99 mTc-ethyl cysteinate dimer (99 mTc-ECD) intravenously during BTO. Although all the patients had passed the BTO clinically, the CBF maps of three patients revealed significant decrease in the occluded hemisphere. There was no procedure-related morbidity. PCT using intraarterial contrast injection during BTO was performed successfully and safely. Intraarterial injection allowed us to obtain excellent time-attenuation curves by utilizing less contrast material and less radiation doze.
Collapse
|
39
|
Mahnken AH, Klotz E, Lautenschläger M, Scheuering M, Rinck D, Mühlenbruch G, Günther RW, Wildberger JE. Myokardinfarktdarstellung inder MSCT mittels modellbasierter Segmentierung und perfusionsgewichteter Farbcodierung. ROFO-FORTSCHR RONTG 2006. [DOI: 10.1055/s-2006-940734] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
40
|
Tomandl BF, Hammen T, Klotz E, Ditt H, Stemper B, Lell M. Bone-subtraction CT angiography for the evaluation of intracranial aneurysms. AJNR Am J Neuroradiol 2006; 27:55-9. [PMID: 16418356 PMCID: PMC7976055] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
PURPOSE CT angiography (CTA) has been established for detection and therapy planning of intracranial aneurysms. The analysis of aneurysms at the level of the skull base, however, remains difficult because bone prevents a free view. We report initial clinical results of an approach for automatic bone elimination from CTA data. MATERIAL AND METHODS Before the bone-removal process 2 datasets are acquired: nonenhanced spiral CT with reduced dose and contrast-enhanced CTA. The software automatically registers the nonenhanced data onto the CTA data and selectively removes bone. Vascular structures, as well as brain tissue, remain visible. In this study, we investigated 27 patients with 29 aneurysms, 13 of which were located at the skull base. 3D volume-rendered images with and without bone removal were reviewed and compared with digital subtraction angiography by 2 radiologists in consensus. RESULTS All supraclinoidal aneurysms were detected on 3D volume-rendered images of both CTA and bone-subtraction CT angiography (BSCTA). Four intracavernous and 3 paraclinoid aneurysms of the internal carotid artery were not visible or were only partially visible on conventional 3D CTA, whereas they could be optimally visualized with BSCTA. Bone removal was successful in all patients; the average additional time for postprocessing was 6.2 minutes. In 7 patients (26%), perfect bone removal without any artifacts was achieved. In most patients, some bone remnants were still present, though it did not disturb the 3D visualization of vascular structures. CONCLUSION BSCTA allows robust and fast selective elimination of bony structures, thus ascertaining a better analysis of arteries at the level of the skull base. This is useful for both detection and therapy planning of intracranial aneurysms.
Collapse
|
41
|
Lell M, Anders K, Klotz E, Ditt H, Bautz W, Tomandl BF. Clinical evaluation of bone-subtraction CT angiography (BSCTA) in head and neck imaging. Eur Radiol 2005; 16:889-97. [PMID: 16267665 DOI: 10.1007/s0330-005-0032-1] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2005] [Revised: 08/09/2005] [Accepted: 09/13/2005] [Indexed: 11/27/2022]
Abstract
Fifty-one patients were examined with bone subtraction CT angiography (BSCTA). Data were acquired on 4-and 64-slice spiral CT systems. The post-processing method is based on fully automatic registration of non-enhanced and contrast-enhanced CT data and subsequent selective bone removal. Vascular structures and brain tissue are retained with the original CTA noise level. Image quality and delineation of the pathologic process were assessed and artifacts introduced by the bone removal process recorded. The bone subtraction algorithm worked successfully in all examinations. The processing time was 6 min on average. Image quality was rated excellent in 20 (39%), good in 26 (51%) and acceptable in 5 (10%) patients. Ophthalmic arteries were visible in 12 (24%) patients bilaterally, in 13 (25%) patients unilaterally and in 26 (51%) patients at least at the origin. BSCTA improved visualization of the infraclinoid ICA and the vertebral arteries. The depiction of stenosis of the extracranial ICA and supraclinoid aneurysms was not significantly improved. In patients with suspicion of sinus thrombosis, BSCTA and conventional CTA yielded similar results. To conclude, BSCTA improves the visualization of vessels with close contact to bone and can improve the diagnostic accuracy and therapy planning of infraclinoid aneurysms.
Collapse
|
42
|
Wildberger JE, Klotz E, Ditt H, Mahnken AH, Spüntrup E, Günther RW. Multi-slice CT for Visualization of Acute Pulmonary Embolism: Single Breath-hold Subtraction Technique. ROFO-FORTSCHR RONTG 2005; 177:17-23. [PMID: 15657816 DOI: 10.1055/s-2004-813875] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
PURPOSE The purpose of our preliminary animal study was to evaluate the feasibility of a new subtraction technique for visualization of perfusion defects within the lung parenchyma in segmental and subsegmental pulmonary embolism (PE). MATERIALS AND METHODS In three healthy pigs, PE were artificially induced by fresh human clot material. Within a single breath-hold, CT angiography (CTA) was performed on a 16-slice multi-slice CT scanner (SOMATOM Sensation 16; Siemens, Forchheim, Germany) before and after intravenous application of 80 mL of contrast-medium, followed by a saline chaser. Scan parameters were 120 kV and 100 mAs (eff.), using a collimation of 16 x 1.5 mm and a table speed/rot. of 36 mm (pitch: 1.5; rotation time: 0.5 s). A new 3D subtraction technique was developed, which is based on automated segmentation, non-linear spatial filtering and non-rigid registration. Data were analysed using a color-encoded "compound view" of parenchymal enhancement and CTA information displayed in axial, coronal and sagittal orientation. RESULTS Subtraction was technically feasible in all three data sets. The mean scan time for each series was 4.7 s, interscan delay was 14.7 s, respectively. Therefore, an average breath-hold of approximately 24 s was required for the overall scanning procedure. Downstream of occluded segmental and subsegmental arteries, perfusion defects were clearly assessable, showing lower or missing enhancement compared to normally perfused lung parenchyma. In all pigs, additional peripheral areas with triangular shaped perfusion defects were delineated, considered typical for PE. CONCLUSIONS Our initial results from the animal model studied show that perfusion imaging of PE is feasible within a single breath-hold. It allows a comprehensive assessment of perfusion deficits as the direct proof of a pulmonary embolus, can be combined with an indirect visual quantification of the density changes in the adjacent lung tissue.
Collapse
|
43
|
Handschu R, Fateh-Moghadam S, Klotz E, Schmid A, Stemper B, Heckmann JG, Huk WJ, Neundörfer B, Tomandl BF. Multimodale Computertomographie beim akuten Hirninfarkt. DER NERVENARZT 2004; 75:564-76. [PMID: 15257380 DOI: 10.1007/s00115-003-1617-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
Computed tomography (CT) is the standard method of brain imaging in acute stroke. To an experienced examiner, nonenhanced CT will exclude hemorrhage and may indicate early ischemic signs. Reliable description of an ischemic area and the underlying vascular disease is not possible in the acute phase but is possible, particularly within the first hours, when therapeutic decisions on matters such as systemic thrombolysis are to be made. For such rapid decision-making, imaging must provide more information. Novel, contrast-enhanced CT techniques can provide this information. Perfusion CT (CTP) can show brain perfusion, allowing one to distinguish between reversible and irreversible damage in an ischemic area. Also, CT angiography (CTA) can detect occlusion or stenosis in the relevant vasculature. Using a modern, multislice CT scanner, it is now possible to combine these modalities of imaging. In a fast protocol for emergency evaluation, all three methods can be performed and evaluated to provide the crucial information within 15 min. In the first 102 patients examined within 6 h of symptom onset using this protocol, multimodal CT contributed substantially to therapeutic decisions, even though there are some limitations in these methods.
Collapse
|
44
|
Mahnken A, Klotz E, Henzler D, Hennemuth A, Hohl C, Wildberger JE, Schaller S, Günther RW. Computertomographische Bestimmung des Herzzeitvolumens aus einer Testbolusmessung: in-vitro und in-vivo Ergebnisse. ROFO-FORTSCHR RONTG 2004. [DOI: 10.1055/s-2004-827784] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
45
|
Tröscher-Weber R, Klotz E, Stemper B, Handschu R, Fateh-Moghadam S, Bison B, Huk WJ, Tomandl B. Umfassende Schlaganfalldiagnostik mit der Mehrschicht-CT (MSCT). ROFO-FORTSCHR RONTG 2004. [DOI: 10.1055/s-2004-828186] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
46
|
Dassel MS, Ditt H, Troescher-Weber R, Bison B, Huk W, Klotz E, Tomandl B. Knochen-Subtraktions-CT-Angiographie (BSCTA) zur verbesserten Darstellung von intrakraniellen Aneurysmen – Vergleich mit konventioneller CTA und DSA. ROFO-FORTSCHR RONTG 2004. [DOI: 10.1055/s-2004-827639] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
47
|
Rasche V, Schreiber B, Graeff C, Istel T, Schomberg H, Grass M, Koppe R, Klotz E, Rose G. Performance of image intensifier-equipped X-ray systems for three-dimensional imaging. ACTA ACUST UNITED AC 2003. [DOI: 10.1016/s0531-5131(03)00321-2] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
48
|
Kirchhof K, Schramm P, Klotz E, Sartor K. [The value of multi-slice computed tomography for early diagnosis of focal cerebral ischemia]. ROFO-FORTSCHR RONTG 2002; 174:1089-95. [PMID: 12221565 DOI: 10.1055/s-2002-33930] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
The aim of this survey is the characterization of the present value of multi-slice computed tomography (MSCT) for the assessment of hyperacute cerebral ischemia based on our experience and a review of the literature. MSCT is compared with single-slice CT (SSCT) as to the diagnostic value of standard cranial CT, CT angiography (CTA) and perfusion CT. CTA obtained with MSCT surpasses CTA obtained with SSCT. For perfusion CT, the value added by MSCT is small. With regard to standard cranial CT, MSCT and SSCT are considered equivalent. CTA and perfusion CT should be used in patients with acute stroke if the indication for thrombolysis is entertained but diffusion and perfusion weighted MRI cannot be carried out. This applies to both SSCT and MSCT. If advanced MRI and advanced CT are available, MRI continues to be the preferred imaging modality.
Collapse
|
49
|
Schoepf UJ, Kessler MA, Rieger CT, Herzog P, Klotz E, Wiesgigl S, Becker CR, Exarhos DN, Reiser MF. Multislice CT imaging of pulmonary embolism. Eur Radiol 2002; 11:2278-86. [PMID: 11702173 DOI: 10.1007/s003300100948] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2001] [Accepted: 03/29/2001] [Indexed: 10/27/2022]
Abstract
In recent years CT has been established as the method of choice for the diagnosis of central pulmonary embolism (PE) to the level of the segmental arteries. The key advantage of CT over competing modalities is the reliable detection of relevant alternative or additional disease causing the patient's symptoms. Although the clinical relevance of isolated peripheral emboli remains unclear, the alleged poor sensitivity of CT for the detection of such small clots has to date prevented the acceptance of CT as the gold standard for diagnosing PE. With the advent of multislice CT we can now cover the entire chest of a patient with 1-mm slices within one breath-hold. In comparison with thicker sections, the detection rate of subsegmental emboli can be significantly increased with 1-mm slices. In addition, the interobserver correlation which can be achieved with 1-mm sections by far exceeds the reproducibility of competing modalities. Meanwhile use of multislice CT for a combined diagnosis of PE and deep venous thrombosis with the same modality appears to be clinically accepted. In the vast majority of patients who receive a combined thoracic and venous multislice CT examination the scan either confirms the suspected diagnosis or reveals relevant alternative or additional disease. The therapeutic regimen is usually chosen based on the functional effect of embolic vascular occlusion. With the advent of fast CT scanning techniques, also functional parameters of lung perfusion can be non-invasively assessed by CT imaging. These advantages let multislice CT appear as an attractive modality for a non-invasive, fast, accurate, and comprehensive diagnosis of PE, its causes, effects, and differential diagnoses.
Collapse
|
50
|
Ohnesorge B, Flohr T, Fischbach R, Kopp AF, Knez A, Schröder S, Schöpf UJ, Crispin A, Klotz E, Reiser MF, Becker CR. Reproducibility of coronary calcium quantification in repeat examinations with retrospectively ECG-gated multisection spiral CT. Eur Radiol 2002; 12:1532-40. [PMID: 12042964 DOI: 10.1007/s00330-002-1394-2] [Citation(s) in RCA: 125] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2001] [Accepted: 02/11/2002] [Indexed: 12/22/2022]
Abstract
High reproducibility is a key requirement for coronary calcium scoring in follow-up examinations. We investigated the inter-examination reproducibility of calcium scoring with retrospectively ECG-gated multisection spiral CT (MSCT). Fifty patients were examined twice with MSCT. Slices were reconstructed with retrospective ECG gating in the diastolic phase with 3-mm slice width and up to 125-ms temporal resolution. We calculated the Agatston score, calcium volume with and without isotropic interpolation, and calcium mass, and derived the mean and median variability. We investigated the change of variability with use of 3-mm non-overlapping and overlapping increments (2, 1.5, 1 mm). Use of overlapping increment results in considerably reduced interscan variability. We observed a minimum mean variability of 12% and a minimum median variability of 9% for the Agatston score. For volume and mass quantification we obtained a minimum mean variability of 7.5% and a minimum median variability of 5%. Multisection spiral CT enables coronary calcium quantification with high reproducibility in follow-up examinations mainly founded on image data with reduced partial-volume errors due to overlapping increment.
Collapse
|