26
|
Abstract
In total hip arthroplasty, steep cup inclination should be avoided because it increases the risk of edge loading. Pelvic posterior tilt should be carefully monitored because it increases cup inclination and anteversion, leading to edge loading or impingement. The authors evaluated how much the pelvic tilt angle changes from the supine position referenced in planning for cup orientation preoperatively to the standing position 1 year after total hip arthroplasty (Δref). The pelvic tilt angle was measured in 124 patients who underwent total hip arthroplasty due to osteoarthritis, and the mean Δref was -9.5°±5.3° (range, -23° to 5°). Preoperative compression fractures, spondylolisthesis, and disk-space narrowing were predictive of increased pelvic posterior tilt after total hip arthroplasty. The authors mathematically calculated how much change in pelvic posterior tilt was clinically possible with the original cup alignment, which ranged from 40° to 45° of radiographic inclination and 0° to 30° radiographic anteversion to more than 50° of inclination. Even if the maximum posterior tilt (23°) occurred, no edge loading would occur in almost half of those original cups. Surgeons should aim for 40° of inclination. When the original cup inclination was 40°, edge loading was prevented. Edge loading caused by steep cup inclination can be prevented by adjusting the cup orientation to account for predicted pelvic tilting, but spinal alignment must also be considered because lumbar kyphosis can increase postoperative pelvic posterior tilt.
Collapse
|
27
|
Sugihara M, Okamoto Y, Hirota T, Suzuki T, Horikoshi M, Hagiya C, Miki H, Yokosawa M, Hagiwara S, Takano Y, Umeda N, Kondo Y, Tsuboi H, Ogishima H, Hayashi T, Chino Y, Goto D, Matsumoto I, Sumida T. AB1281 Making a diagnosis and predicting prognosis of bone structure by low field compact magnetic resonance imaging machine in patients with rheumatoid arthritis. Ann Rheum Dis 2013. [DOI: 10.1136/annrheumdis-2012-eular.1277] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|
28
|
Miki H, Sugano N, Yonenobu K, Tsuda K, Hattori M, Suzuki N. Detecting cause of dislocation after total hip arthroplasty by patient-specific four-dimensional motion analysis. Clin Biomech (Bristol, Avon) 2013; 28:182-6. [PMID: 23219052 DOI: 10.1016/j.clinbiomech.2012.11.009] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/21/2012] [Revised: 11/07/2012] [Accepted: 11/12/2012] [Indexed: 02/07/2023]
Abstract
BACKGROUND Dislocation is a major complication after total hip arthroplasty. Prosthesis impingement is considered to be an important cause of dislocation because impingement marks are more frequently found on retrieved cups or liners in patients who have undergone revision surgery because of dislocation (80%-94%) than in those who have undergone reoperation for other reasons (51%-56%). However, it remains a question whether impingement marks are the cause of dislocation or are instead its result. To clarify the issue, it is necessary to confirm noninvasively whether the point of impingement matches the patient's hip position when dislocation occurs. METHODS Using four-dimensional patient-specific analysis, we recorded prosthesis impingement in 10 hips with instability after primary total hip arthroplasty when the patients reproduced the dislocation-causing motion. FINDINGS We found prosthesis impingement to be related to at least instability in 6 of 10 hips with dislocation after primary total hip arthroplasty and in 4 of 4 hips that underwent revision surgery for recurrent dislocation. All impingements occurred between the anterior wall of the liner and the stem neck in posterior dislocation and between the posterior wall of the liner and the stem neck in anterior dislocation. Revision surgery in 1 of those 4 hips revealed 2 impingement marks on the retrieved liner that closely matched the prosthesis impingement point and the dislocation pathway of the metal head on the liner that were detected earlier during motion analysis. INTERPRETATION Prosthesis impingement is an important factor in dislocation after total hip arthroplasty.
Collapse
|
29
|
Miki H, Kyo T, Sugano N. Anatomical hip range of motion after implantation during total hip arthroplasty with a large change in pelvic inclination. J Arthroplasty 2012; 27:1641-1650.e1. [PMID: 22521398 DOI: 10.1016/j.arth.2012.03.002] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/19/2011] [Accepted: 03/01/2012] [Indexed: 02/01/2023] Open
Abstract
The supine functional pelvic plane is the recommended reference pelvic plane for acetabular cup planning in navigation-assisted total hip arthroplasty. However, it is unclear whether it can be used in patients with a large preoperative positional change in pelvic inclination (PC) from the supine to the standing position because it is unknown whether these patients have a different hip range of motion (ROM). We measured the anatomical hip ROM after implantation by computed tomography-based navigation in 91 patients and found it to be similar between those with a small PC (<10°) and those with a large PC (≥10°). There was no significant correlation between ROM and preoperative PC. The supine functional pelvic plane is adequate for cup planning whether the PC is small or large.
Collapse
|
30
|
Ikegame A, Ozaki S, Tsuji D, Harada T, Fujii S, Nakamura S, Miki H, Nakano A, Kagawa K, Takeuchi K, Abe M, Watanabe K, Hiasa M, Kimura N, Kikuchi Y, Sakamoto A, Habu K, Endo M, Itoh K, Yamada-Okabe H, Matsumoto T. Small molecule antibody targeting HLA class I inhibits myeloma cancer stem cells by repressing pluripotency-associated transcription factors. Leukemia 2012; 26:2124-34. [PMID: 22430632 DOI: 10.1038/leu.2012.78] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2011] [Revised: 02/16/2012] [Accepted: 02/28/2012] [Indexed: 02/01/2023]
Abstract
Cancer stem cells have been proposed to be responsible for tumorigenesis and recurrence in various neoplastic diseases, including multiple myeloma (MM). We have previously reported that MM cells specifically express HLA class I at high levels and that single-chain Fv diabody against this molecule markedly induces MM cell death. Here we investigated the effect of a new diabody (C3B3) on cancer stem cell-like side population (SP) cells. SP fraction of MM cells highly expressed ABCG2 and exhibited resistance to chemotherapeutic agents; however, C3B3 induced cytotoxicity in both SP cells and main population (MP) cells to a similar extent. Moreover, C3B3 suppressed colony formation and tumorigenesis of SP cells in vitro and in vivo. Crosslinking of HLA class I by C3B3 mediated disruption of lipid rafts and actin aggregation, which led to inhibition of gene expression of β-catenin and pluripotency-associated transcription factors such as Sox2, Oct3/4 and Nanog. Conversely, knockdown of Sox2 and Oct3/4 mRNA reduced the proportion of SP cells, suggesting that these factors are essential in maintenance of SP fraction in MM cells. Thus, our findings reveal that immunotherapeutic approach by engineered antibodies can overcome drug resistance, and provide a new basis for development of cancer stem cell-targeted therapy.
Collapse
|
31
|
Sugano N, Tsuda K, Miki H, Takao M, Suzuki N, Nakamura N. Dynamic measurements of hip movement in deep bending activities after total hip arthroplasty using a 4-dimensional motion analysis system. J Arthroplasty 2012; 27:1562-8. [PMID: 22459125 DOI: 10.1016/j.arth.2012.01.029] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/04/2011] [Accepted: 01/29/2012] [Indexed: 02/01/2023] Open
Abstract
Although deep hip bending activities are often required in Asian populations because of traditional lifestyles and religious practices, few have examined the required hip range of motion (ROM) in these activities after total hip arthroplasty (THA). We performed postoperative motion analysis to evaluate the differences in required ROMs between Japanese-style and Western-style deep hip bending activities, to investigate whether prosthetic impingement would occur during these activities and to clarify the necessity for precautions in these activities after THA. Japanese-style activities did not require larger hip ROMs than Western-style ones, and all required hip flexion angles were less than 120°. Prosthetic impingement was not observed, with a safety margin 10° or higher until impingement in any directions of flexion, adduction, or internal rotation for any activities. Thus, particular postoperative precautions for Japanese-style activities are not required.
Collapse
|
32
|
Sugano N, Takao M, Sakai T, Nishii T, Miki H, Ohzono K. Eleven- to 14-year follow-up results of cementless total hip arthroplasty using a third-generation alumina ceramic-on-ceramic bearing. J Arthroplasty 2012; 27:736-41. [PMID: 21978563 DOI: 10.1016/j.arth.2011.08.017] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/03/2011] [Accepted: 08/20/2011] [Indexed: 02/01/2023] Open
Abstract
To analyze long-term survivorship of cementless total hip arthroplasties (THAs) with the third-generation alumina ceramic-on-ceramic bearing, 100 consecutive THAs between 1996 and 1998 were reviewed. One cup and 2 stems were revised due to aseptic loosening. Another cup showed chipping of the acetabular liner at 8 years and required cup revision. The remaining hips showed stable bone ingrowth fixation with no osteolysis at the final follow-up. The 14-year survivorship as the end point of revision was 97.9% for the cup, 97.8% for the stem, and 95.7% for the overall implants, respectively. We conclude that cementless THA with the third-generation ceramic-on-ceramic hip bearing provided an excellent survivorship and eliminated periprosthetic osteolysis for 11 to 14 years.
Collapse
|
33
|
Pezzotti G, Takahashi Y, Takamatsu S, Puppulin L, Nishii T, Miki H, Sugano N. Non-destructively Differentiating the Roles of Creep, Wear and Oxidation in Long-Term In Vivo Exposed Polyethylene Cups. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2012; 22:2165-84. [DOI: 10.1163/092050610x537129] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
34
|
Miki H, Funato Y. Regulation of intracellular signalling through cysteine oxidation by reactive oxygen species. J Biochem 2012; 151:255-61. [DOI: 10.1093/jb/mvs006] [Citation(s) in RCA: 167] [Impact Index Per Article: 13.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
35
|
Miki H, Sugano N. Modular neck for prevention of prosthetic impingement in cases with excessively anteverted femur. Clin Biomech (Bristol, Avon) 2011; 26:944-9. [PMID: 21680069 DOI: 10.1016/j.clinbiomech.2011.05.016] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/25/2011] [Revised: 05/26/2011] [Accepted: 05/30/2011] [Indexed: 02/07/2023]
Abstract
BACKGROUND It is important to adjust stem anteversion in cases of excessive femoral version to avoid prosthetic impingement-related complications in total hip arthroplasty. Although modular necks are considered an effective solution, their application in cases with wide variations in femoral anteversion remains to be elucidated. This study aimed to simulate the effects of different modular necks on prevention of prosthetic impingement due to excessive femoral anteversion. METHODS We investigated range of motion without prosthetic impingement by collision detection using implant computer-aided design models of the ANCA-Fit system. FINDINGS Modular necks could provide an adequate range of motion in cases with up to 60° of femoral anteversion. However, few alternative necks were available in cases with excessive femoral anteversion, while many options could be used for femoral offset and version control in cases with average amounts of femoral anteversion without prosthetic impingement. INTERPRETATION We conclude that modular necks might provide a marginal advantage over other options such as cemented, conical or modular stems for cases with an excessively anteverted femur, although they could help to maintain the femoral offset in some cases with average femoral anteversion.
Collapse
|
36
|
Ogawa Y, Nishida Y, Kyo T, Miki H, Yonemoto H, Bandou H, Yajima K, Kasai D, Taniguchi T, Watanabe D, Uehira T, Ueda T, Shirasaka T. [Successful completion of left total hip arthroplasty by inhibitor neutralization therapy in a hemophilia B patient with high responding inhibitor]. [RINSHO KETSUEKI] THE JAPANESE JOURNAL OF CLINICAL HEMATOLOGY 2011; 52:713-717. [PMID: 21897080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Major surgery in hemophilia patients has been facilitated by the development of coagulation concentrates. However, it is still difficult to manage bleeding during major surgery in patients with inhibitors to FVIII/IX. In addition, there have been few reports of major surgery in hemophilia B with high responding inhibitors. We report a 26-year-old hemophilia B patient with high responding factor IX inhibitor who demonstrated severe hemophiliac arthropathy in his left hip joint. Total hip arthroplasty was performed with a high dose of FIX followed by recombinant FVIIa. His inhibitor titer was decreased from 111 BU/ml to 1.0 BU/ml at surgery by avoiding the use of FIX concentrates. Thus, we could use high dose FIX for the management of surgical bleeding. Anamnestic response occurred on the 7th day after surgery and FIX concentrates were switched to recombinant FVIIa. The whole process was safely managed without any excess bleeding or adverse effects. The successful use of high dose FIX followed by recombinant FVIIa suggests that even major surgery could be safely performed in hemophilia B patients with a low titer of high responding inhibitors.
Collapse
|
37
|
Morinaka A, Funato Y, Uesugi K, Miki H. Oligomeric peroxiredoxin-I is an essential intermediate for p53 to activate MST1 kinase and apoptosis. Oncogene 2011; 30:4208-18. [PMID: 21516123 DOI: 10.1038/onc.2011.139] [Citation(s) in RCA: 74] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Mammalian Ste20-like kinase-1 (MST1) kinase mediates H₂O₂-induced cell death by anticancer drugs such as cisplatin in a p53-dependent manner. However, the mechanism underlying MST1 activation by H₂O₂ remains unknown. Here we show that peroxiredoxin-I (PRX-I) is an essential intermediate in H₂O₂-induced MST1 activation and cisplatin-induced cell death through p53. Cell stimulation with H₂O₂ resulted in PRX-I oxidation to form homo-oligomers and interaction with MST1, leading to MST1 autophosphorylation and augmentation of kinase activity. In addition, RNA interference knockdown experiments indicated that endogenous PRX-I is required for H₂O₂-induced MST1 activation. Live-cell imaging showed H₂O₂ generation by cisplatin treatment, which likewise caused PRX-I oligomer formation, MST1 activation and cell death. Cisplatin-induced PRX-I oligomer formation was not observed in embryonic fibroblasts obtained from p53-knockout mice, confirming the importance of p53. Indeed, ectopic expression of p53 induced PRX-I oligomer formation and cell death, both of which were cancelled by the antioxidant NAC. Moreover, we succeeded in reconstituting H₂O₂-induced MST1 activation in vitro, using purified PRX-I and MST1 proteins. Collectively, our results show a novel PRX-I function to cause cell death in response to high levels of oxidative stress by activating MST1, which underlies the p53-dependent cytotoxicity caused by anticancer agents.
Collapse
|
38
|
Nagano Y, Miki H, Tsuda K, Shimizu Y, Fukubayashi T. Prevention of anterior cruciate ligament injuries in female basketball players in japan: an intervention study over four seasons. Br J Sports Med 2011. [DOI: 10.1136/bjsm.2011.084038.155] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
39
|
Takao M, Ohzono K, Nishii T, Miki H, Nakamura N, Sugano N. Cementless modular total hip arthroplasty with subtrochanteric shortening osteotomy for hips with developmental dysplasia. J Bone Joint Surg Am 2011; 93:548-55. [PMID: 21411705 DOI: 10.2106/jbjs.i.01619] [Citation(s) in RCA: 70] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND The purpose of this retrospective study was to analyze the functional and radiographic results of cementless, modular total hip arthroplasty combined with subtrochanteric osteotomy for the treatment of patients who had had Crowe Group-IV developmental dysplasia of the hip as a child. METHODS Twenty-five consecutive patients (thirty-three hips) who had previously had Crowe Group-IV developmental dysplasia of the hip were treated with a modular cementless prosthesis at a mean age of sixty years. The mean follow-up period was eight years (range, five to eleven years). The acetabular cup was placed in the position of the anatomical hip center in every patient. Subtrochanteric femoral shortening osteotomy was performed with use of a step-cut design. RESULTS The mean Merle d'Aubigné and Postel hip score improved from 9 to 16 points (out of a maximum of 18 points). The mean limb-length discrepancy in seventeen patients with unilateral involvement was reduced from 5.1 cm (range, 3.7 to 6.5 cm) to 2.8 cm (range, 1.4 to 4.6 cm). Two patients had a positive Trendelenburg sign, and three had a slight limp at the time of the latest follow-up. No cases of nonunion or nerve palsy were encountered. Postoperative dislocations occurred in two hips. One hip showed progressive radiolucent lines around the proximal femoral sleeve within two years after the surgery, and this was followed by progressive stem subsidence. Only one femoral stem was revised. CONCLUSIONS Cementless, modular total hip arthroplasty combined with subtrochanteric osteotomy for the treatment of patients with prior Crowe Group-IV developmental dysplasia of the hip resulted in satisfactory outcomes. Hips with poor bone quality and a developmentally short femoral neck present technical challenges with regard to achieving sufficient rotatory stability, following osteotomy, for osseointegration of the modular implants. LEVEL OF EVIDENCE Therapeutic Level IV. See Instructions to Authors for a complete description of levels of evidence.
Collapse
|
40
|
Nakahara I, Nakamura N, Nishii T, Miki H, Sakai T, Sugano N. Minimum five-year follow-up wear measurement of longevity highly cross-linked polyethylene cup against cobalt-chromium or zirconia heads. J Arthroplasty 2010; 25:1182-7. [PMID: 19879725 DOI: 10.1016/j.arth.2009.09.006] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/18/2009] [Accepted: 09/25/2009] [Indexed: 02/01/2023] Open
Abstract
We investigated the efficacy of combining highly cross-linked polyethylene with ceramic heads on further reduction in polyethylene wear compared with the combination with cobalt-chromium heads via PolyWare computer-assisted method. A prospective cohort study was performed on 102 cementless total hip arthroplasties using Longevity (Zimmer, Warsaw, Ind) highly cross-linked polyethylene liners. Either 26-mm zirconia heads or 26-mm cobalt-chromium heads were randomly used in 51 hips each. At a mean follow-up of 6.7 years, no significant differences were identified between the groups for total penetration rate and steady-state wear rate. Osteolysis was not observed in any hips in either group. In conclusion, no advantage was seen for the 26-mm zirconia head compared with the 26-mm cobalt-chromium head in this period.
Collapse
|
41
|
Yamaoka M, Hara T, Miki H, Hitaka T, Kaku T, Ito T, Kawaguchi N, Yamasaki H, Tasaka A, Kusaka M. 163 Effect of a novel, investigational 17,20-lyase inhibitor, TAK-700, on enzyme activity and serum androgen levels in human H295R cells and cynomolgus monkeys. EJC Suppl 2010. [DOI: 10.1016/s1359-6349(10)71868-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
|
42
|
Sakai T, Ohzono K, Nishii T, Miki H, Takao M, Sugano N. Grafting with hydroxyapatite granules for defects of acetabular bone at revision total hip replacement. ACTA ACUST UNITED AC 2010; 92:1215-21. [DOI: 10.1302/0301-620x.92b9.24555] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
The long-term results of grafting with hydroxyapatite granules for acetabular deficiency in revision total hip replacement are not well known. We have evaluated the results of revision using a modular cup with hydroxyapatite grafting for Paprosky type 2 and 3 acetabular defects at a minimum of ten years’ follow-up. We retrospectively reviewed 49 acetabular revisions at a mean of 135 months (120 to 178). There was one type 2B, ten 2C, 28 3A and ten 3B hips. With loosening as the endpoint, the survival rate was 74.2% (95% confidence interval 58.3 to 90.1). Radiologically, four of the type 3A hips (14%) and six of the type 3B hips (60%) showed aseptic loosening with collapse of the hydroxyapatite layer, whereas no loosening occurred in type 2 hips. There was consolidation of the hydroxyapatite layer in 33 hips (66%). Loosening was detected in nine of 29 hips (31%) without cement and in one of 20 hips (5%) with cement (p = 0.03, Fisher’s exact probability test). The linear wear and annual wear rate did not correlate with loosening. These results suggest that the long-term results of hydroxyapatite grafting with cement for type 2 and 3A hips are encouraging.
Collapse
|
43
|
Sakai T, Ohzono K, Nishii T, Miki H, Takao M, Sugano N. A modular femoral neck and head system works well in cementless total hip replacement for patients with developmental dysplasia of the hip. ACTA ACUST UNITED AC 2010; 92:770-6. [DOI: 10.1302/0301-620x.92b6.23001] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
We compared a modular neck system with a non-modular system in a cementless anatomical total hip replacement (THR). Each group consisted of 74 hips with developmental hip dysplasia. Both groups had the same cementless acetabular component and the same articulation, which consisted of a conventional polyethylene liner and a 28 mm alumina head. The mean follow-up was 14.5 years (13 to 15), at which point there were significant differences in the mean total Harris hip score (modular/non-modular: 98.6 (64 to 100)/93.8 (68 to 100)), the mean range of abduction (32° (15° to 40°)/28 (0° to 40°)), use of a 10° elevated liner (31%/100%), the incidence of osteolysis (27%/79.7%) and the incidence of equal leg lengths (≥ 6 mm, 92%/61%). There was no disassociation or fracture of the modular neck. The modular system reduces the need for an elevated liner, thereby reducing the incidence of osteolysis. It gives a better range of movement and allows the surgeon to make an accurate adjustment of leg length.
Collapse
|
44
|
Sugano N, Miki H, Nakamura N, Aihara M, Yamamoto K, Ohzono K. Clinical efficacy of mechanical thromboprophylaxis without anticoagulant drugs for elective hip surgery in an Asian population. J Arthroplasty 2009; 24:1254-7. [PMID: 19577898 DOI: 10.1016/j.arth.2009.05.015] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/25/2008] [Accepted: 05/11/2009] [Indexed: 02/01/2023] Open
Abstract
To evaluate the clinical efficacy of mechanical thromboprophylaxis after elective hip surgery, we reviewed 3016 patients who underwent hip surgery at 5 centers. Primary total hip arthroplasty (THA), revision THA, and pelvic or femoral osteotomies were performed in 2648, 298, and 70 patients, respectively. Epidural anesthesia, intraoperative calf bandage, early mobilization, and intermittent pneumatic compression postoperatively with additional use of elastic stockings were the basic regimen for thromboprophylaxis. Postoperatively, no cases of fatal pulmonary embolism (PE) were encountered. One symptomatic PE and 4 symptomatic deep vein thrombosis cases were identified, all of which were successfully treated using heparin and warfarin. By 6 months, no deaths had occurred. We conclude that mechanical thromboprophylaxis without anticoagulant drugs is safe and effective for elective hip surgeries in our patient population.
Collapse
|
45
|
Iwai A, Hamada Y, Takada K, Inagaki N, Nakatake R, Yanai H, Miki H, Araki Y, Sato M, Ono S, Iwai N, Kwon AH. Choledochal cyst associated with duodenal atresia: case report and review of the literature. Pediatr Surg Int 2009; 25:995-8. [PMID: 19693517 DOI: 10.1007/s00383-009-2462-3] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
We report a rare case of choledochal cyst (CC) associated with congenital duodenal atresia (DA) and annular pancreas (AP). A girl was born at 37 weeks of gestation weighing 2,974 g with a prenatal diagnosis of DA. She underwent a duodenoduodenostomy for type III DA with an AP 1 day after birth. At 4 years of age, she was admitted for evaluation of cholangitis and pancreatitis. Radiological studies demonstrated a fusiform-type CC with pancreaticobiliary maljunction (PBMJ). Excision of the CC and hepaticojejunostomy were performed. The patient was discharged without complications. Despite the fact that CC, DA, and AP are embryologically closely related entities, to the best of our knowledge, only eight such cases have been documented. We must be aware of the possible combination of CC in the follow-up of the patients with DA associated with AP.
Collapse
|
46
|
Sugano N, Takao M, Sakai T, Nishii T, Miki H, Nakamura N. Comparison of mini-incision total hip arthroplasty through an anterior approach and a posterior approach using navigation. Orthop Clin North Am 2009; 40:365-70. [PMID: 19576404 DOI: 10.1016/j.ocl.2009.04.003] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
This study reports on differences in the use of minimally invasive surgery for total hip arthroplasty related to the direction of cup insertion against the operating table, intraoperative hip range of motion, stability, and a choice of cup liners for both a mini-incision posterior approach (MPA) and a mini-incision anterior approach (MAA) using Stryker Navigation's CT-Hip system. The MPA group consisted of 39 consecutive patients and the MAA group consisted of 33 consecutive patients. Clinically, there was no significant difference in the average Japanese Orthopedic Association hip score or the Oxford hip score preoperatively and at 6 months and 2 years follow-up. The intraoperative joint stability measurements showed no large difference between the two groups when malpositioning of the cup was eliminated.
Collapse
|
47
|
Hananouchi T, Takao M, Nishii T, Miki H, Iwana D, Yoshikawa H, Sugano N. Comparison of navigation accuracy in THA between the mini-anterior and -posterior approaches. Int J Med Robot 2009; 5:20-5. [PMID: 19107818 DOI: 10.1002/rcs.226] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
BACKGROUND The accuracy of a CT-based hip navigation might depend on surgical approaches, resulting in varying accuracy of implant alignment. METHODS We performed primary cementless total hip arthroplasty (THA) with mini-incision surgery (MIS) to 40 well-matched patients (anterior or posterior approaches, 20 hips each), using navigation with surface registration. We investigated cup alignment using postoperative computed tomography (CT) and compared the navigation accuracy between the two approaches, i.e. the difference between intra-operative and postoperative alignments of the cup. RESULTS There was no significant difference between the two approaches. The mean navigation accuracies in abduction and anteversion were 2.0 degrees (SD 1.4 degrees) and 2.7 degrees (SD 1.9 degrees), respectively, in the anterior approach, and 2.4 degrees (SD 2.0 degrees) and 2.0 degrees (SD 1.4 degrees), respectively, in the posterior approach. All cup alignments were within 10 degrees of the target orientation. CONCLUSIONS This CT-based navigation for MIS-THA provides navigation accuracy without significant differences between the two approaches and with favourable alignment of the cup.
Collapse
|
48
|
Miki H, Wakisaka N, Inoue K, Ogonuki N, Mori M, Kim JM, Ohta A, Ogura A. Embryonic rather than extraembryonic tissues have more impact on the development of placental hyperplasia in cloned mice. Placenta 2009; 30:543-6. [PMID: 19345413 DOI: 10.1016/j.placenta.2009.03.006] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/09/2009] [Revised: 03/08/2009] [Accepted: 03/10/2009] [Indexed: 11/15/2022]
Abstract
Somatic cell cloning by nuclear transfer (NT) in mice is associated with hyperplastic placentas at term. To dissect the effects of embryonic and extraembryonic tissues on this clone-associated phenotype, we constructed diploid (2n) fused with (<-->) tetraploid (4n) chimeras from NT- and fertilization-derived (FD) embryos. Generally, the 4n cells contributed efficiently to all the extraembryonic tissues but not to the embryo itself. Embryos constructed by 2n NT<-->4n FD aggregation developed hyperplastic placentas (0.33+/-0.22 g) with a predominant contribution by NT-derived cells. Even when the population of FD-derived cells in placentas was increased using multiple FD embryos (up to four) for aggregation, most placentas remained hyperplastic (0.36+/-0.13 g). By contrast, placentas of the reciprocal combination, 2n FD<-->4n NT, were less hyperplastic (0.15+/-0.02 g). These nearly normal-looking placentas had a large proportion of NT-derived cells. Thus, embryonic rather than extraembryonic tissues had more impact on the onset of placental hyperplasia, and that the abnormal placentation in clones occurs in a noncell-autonomous manner. These findings suggest that for improvement of cloning efficiency we should understand the mechanisms regulating placentation, especially those of embryonic origin that might control the proliferation of trophoblastic lineage cells.
Collapse
|
49
|
Koyama T, Sugano N, Nishii T, Miki H, Takao M, Sato Y, Yoshikawa H, Tamura S. MRI-based surgical simulation of transtrochanteric rotational osteotomy for femoral head osteonecrosis. J Orthop Res 2009; 27:447-51. [PMID: 18932234 DOI: 10.1002/jor.20568] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Transtrochanteric rotational osteotomy (TRO) is one of the joint-preserving surgical treatments for osteonecrosis of the femoral head (ONFH). It can prevent collapse of the femoral head as necrotic lesions in the weight-bearing portion can be moved sufficiently to a less weight-bearing portion by anterior rotation, posterior rotation, or varus angulation. Patient selection and preoperative planning are important to determine indications for TRO. It has been reported that successful TRO requires at least 34% of the weight-bearing area supported by the intact part of the femoral head. However, this ratio is difficult to preoperatively quantify according to the rotation angle using conventional two-dimensional MR images or X-rays. Therefore, we developed a method of simulating TRO using three-dimensional (3D) models reconstructed from 3D MR images and applied it to serial patients with types C1 and C2 osteonecrosis at stage 1 or 2. The simulation visualized positional changes of the necrotic lesion in the weight-bearing area and enabled quantitation of the postoperative intact ratio. Our surgical simulation is useful for evaluating the postoperative intact ratio and for determining indications for TRO as well as the optimal angle of femoral head rotation and varus angulation.
Collapse
|
50
|
Nakamura N, Sugano N, Nishii T, Miki H, Kakimoto A, Yamamura M. Robot-assisted primary cementless total hip arthroplasty using surface registration techniques: a short-term clinical report. Int J Comput Assist Radiol Surg 2009; 4:157-62. [DOI: 10.1007/s11548-009-0286-1] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2008] [Accepted: 12/29/2008] [Indexed: 11/28/2022]
|