26
|
Abissi P, Lymperopoulou G, Koutoulidis V, Grigoropoulos P, Papagiannis P, Seimenis I, Fiebich M, Agrokostas V. EVALUATION OF RADIATION BURDEN AND ASSOCIATED RISK IN SMOLDERING MULTIPLE MYELOMA PATIENTS MONITORED USING REPEATED CT IMAGING. Phys Med 2022. [DOI: 10.1016/s1120-1797(22)03047-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
|
27
|
Christidi F, Tsiptsios D, Fotiadou A, Kitmeridou S, Karatzetzou S, Tsamakis K, Sousanidou A, Psatha EA, Karavasilis E, Seimenis I, Kokkotis C, Aggelousis N, Vadikolias K. Diffusion Tensor Imaging as a Prognostic Tool for Recovery in Acute and Hyperacute Stroke. Neurol Int 2022; 14:841-874. [PMID: 36278693 PMCID: PMC9589952 DOI: 10.3390/neurolint14040069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2022] [Revised: 10/17/2022] [Accepted: 10/17/2022] [Indexed: 11/16/2022] Open
Abstract
Stroke represents a major cause of mortality and long-term disability among adult populations, leaving a devastating socioeconomic impact globally. Clinical manifestation of stroke is characterized by great diversity, ranging from minor disability to considerable neurological impairment interfering with activities of daily living and even death. Prognostic ambiguity has stimulated the interest for implementing stroke recovery biomarkers, including those provided by structural neuroimaging techniques, i.e., diffusion tensor imaging (DTI) and tractography for the study of white matter (WM) integrity. Considering the necessity of prompt and accurate prognosis in stroke survivors along with the potential capacity of DTI as a relevant imaging biomarker, the purpose of our study was to review the pertinent literature published within the last decade regarding DTI as a prognostic tool for recovery in acute and hyperacute stroke. We conducted a thorough literature search in two databases (MEDLINE and Science Direct) in order to trace all relevant studies published between 1 January 2012 and 16 March 2022 using predefined terms as key words. Only full-text human studies published in the English language were included. Forty-four studies were identified and are included in this review. We present main findings and by describing several methodological issues, we highlight shortcomings and gaps in the current literature so that research priorities for future research can be outlined. Our review suggests that DTI can track longitudinal changes and identify prognostic correlates in acute and hyperacute stroke patients.
Collapse
|
28
|
Archontakis P, Moutsatsos A, Papagiannis P, Seimenis I, Pantelis E. Spatial distribution of the imaging dose and characterization of the scatter radiation contribution in CyberKnife radiosurgery. Phys Med 2022; 103:11-17. [PMID: 36183580 DOI: 10.1016/j.ejmp.2022.09.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Revised: 07/07/2022] [Accepted: 09/26/2022] [Indexed: 10/31/2022] Open
Abstract
PURPOSE The imaging dose for intra- and extra-cranial CyberKnife radiosurgery applications was calculated and the scattered radiation reaching the digital detectors was quantified and analyzed with regard to its origin. METHODS The image guidance subsystem of the CyberKnife was modeled based on vendor-provided information. The emitted X-ray energy spectrum for 120 kV was estimated using the SpekPy software tool. Monte Carlo (MC) image acquisition simulations were performed to calculate the total, primary and scattered photon fluences reaching each detector as a function of the imaged object dimensions. MC calculations of the imaging dose were performed for intra- and extra-cranial applications assuming 120 kV and 10 mAs acquisition settings. RESULTS The amount of scattered radiation reaching each detector was found to depend on the dimensions of the imaged anatomical region, contributing more than 40 % to the total photon fluence for regions more than 20 cm thick. More than 20 % of this scattered radiation originates from the contralateral imaging field. A maximum organ dose of 1.5 mGy at the nasal bones and an average dose of 0.37 mGy to the eye lenses per image pair acquisition was calculated for head applications. An entrance imaging dose of 0.4 mGy was calculated for extracranial applications. CONCLUSIONS Scattered radiation reaching each detector in the skull and spine tracking applications can be reduced by acquiring the pair of radiographs sequentially instead of simultaneously. A dose of 3.7 cGy to the eye lenses is estimated assuming 100 image pair exposures required for treatment completion.
Collapse
|
29
|
Spyratou E, Ploussi A, Alafogiannis P, Katifelis H, Apostolopoulou S, Bagenakis G, Rammos S, Papagiannis I, Gazouli M, Seimenis I, Georgakilas AG, Efstathopoulos EP. FDXR Gene Expression after in Vivo Radiation Exposure of Pediatric Patients Undergoing Interventional Cardiology Procedures. FRONT BIOSCI-LANDMRK 2022; 27:255. [PMID: 36224003 DOI: 10.31083/j.fbl2709255] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2022] [Revised: 07/19/2022] [Accepted: 07/20/2022] [Indexed: 09/11/2023]
Abstract
BACKGROUND Ferredoxin reductase (FDXR) has already been reported as a promising biomarker for estimating radiation doses in radiotherapy. This study aimed to investigate the responsiveness of FDXR on pediatric population exposed to ionizing radiation (X-rays) during pediatric interventional cardiology (IC) procedures. PATIENTS AND METHODS Peripheral blood was collected by venipuncture from 24 pediatric donors before and 24 hours after the IC procedure. To estimate the effective dose, demographic data and Air Kerma-Area Product (PKA) were recorded for each patient. The relative quantification (RQ) of the FDXR gene in irradiated patient blood samples compared to the non-irradiated blood samples was determined using qPCR analysis. The relative values of FDXR were log- transformed. RESULTS The effective dose ranged from 0.002 mSv to 8.004 mSv. Over this radiation exposure range, the FDXR gene expression varied randomly with the effective dose. Up-regulation in FDXR expression was observed in 17 patients and down-regulation in 7 patients. CONCLUSIONS Further studies in a larger cohort of pediatric patients along with the record of clinical data are needed to determine whether FDXR gene expression is an effective biomarker for radiation exposure estimation in pediatric imaging.
Collapse
|
30
|
Theocharis S, Pappas EP, Seimenis I, Kouris P, Dellios D, Kollias G, Karaiskos P. Geometric distortion assessment in 3T MR images used for treatment planning in cranial Stereotactic Radiosurgery and Radiotherapy. PLoS One 2022; 17:e0268925. [PMID: 35605005 PMCID: PMC9126373 DOI: 10.1371/journal.pone.0268925] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Accepted: 05/10/2022] [Indexed: 12/31/2022] Open
Abstract
Magnetic Resonance images (MRIs) are employed in brain Stereotactic Radiosurgery and Radiotherapy (SRS/SRT) for target and/or critical organ localization and delineation. However, MRIs are inherently distorted, which also impacts the accuracy of the Magnetic Resonance Imaging/Computed Tomography (MRI/CT) co-registration process. In this phantom-based study, geometric distortion is assessed in 3T T2-weighted images (T2WIs), while the efficacy of an MRI distortion correction technique is also evaluated. A homogeneous polymer gel-filled phantom was CT-imaged before being irradiated with 26 4-mm Gamma Knife shots at predefined locations (reference control points). The irradiated phantom was MRI-scanned at 3T, implementing a T2-weighted protocol suitable for SRS/SRT treatment planning. The centers of mass of all shots were identified in the 3D image space by implementing an iterative localization algorithm and served as the evaluated control points for MRI distortion detection. MRIs and CT images were spatially co-registered using a mutual information algorithm. The inverse transformation matrix was applied to the reference control points and compared with the corresponding MRI-identified ones to evaluate the overall spatial accuracy of the MRI/CT dataset. The mean image distortion correction technique was implemented, and resulting MRI-corrected control points were compared against the corresponding reference ones. For the scanning parameters used, increased MRI distortion (>1mm) was detected at areas distant from the MRI isocenter (>5cm), while median radial distortion was 0.76mm. Detected offsets were slightly higher for the MRI/CT dataset (0.92mm median distortion). The mean image distortion correction improves geometric accuracy, but residual distortion cannot be considered negligible (0.51mm median distortion). For all three datasets studied, a statistically significant positive correlation between detected spatial offsets and their distance from the MRI isocenter was revealed. This work contributes towards the wider adoption of 3T imaging in SRS/SRT treatment planning. The presented methodology can be employed in commissioning and quality assurance programmes of corresponding treatment workflows.
Collapse
|
31
|
Archontakis P, Papagiannis P, Seimenis I, Pantelis E. PO-1536 Imaging dose distributions from CyberKnife robotic image guided radiotherapy. Radiother Oncol 2022. [DOI: 10.1016/s0167-8140(22)03500-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
32
|
Christidi F, Karavasilis E, Argyropoulos GD, Velonakis G, Zouvelou V, Murad A, Evdokimidis I, Rentzos M, Seimenis I, Bede P. Neurometabolic Alterations in Motor Neuron Disease: Insights from Magnetic Resonance Spectroscopy. J Integr Neurosci 2022; 21:87. [DOI: 10.31083/j.jin2103087] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Revised: 03/30/2022] [Accepted: 04/15/2022] [Indexed: 11/06/2022] Open
|
33
|
Koutoulidis V, Terpos E, Papanikolaou N, Fontara S, Seimenis I, Gavriatopoulou M, Ntanasis-Stathopoulos I, Bourgioti C, Santinha J, Moreira JM, Kastritis E, Dimopoulos MA, Moulopoulos LA. Comparison of MRI Features of Fat Fraction and ADC for Early Treatment Response Assessment in Participants with Multiple Myeloma. Radiology 2022; 304:137-144. [PMID: 35380497 DOI: 10.1148/radiol.211388] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
Background An imaging-based predictor of response could provide prognostic information early during treatment course in patients with multiple myeloma (MM). Purpose To investigate if very early changes in bone marrow relative fat fraction (rFF) and apparent diffusion coefficient (ADC) histogram metrics, occurring after one cycle of induction therapy in participants with newly diagnosed MM, could help predict overall best response status. Materials and Methods This prospective study included participants with MM who were enrolled between August 2014 and December 2017. Histogram metrics were extracted from ADC and rFF maps from MRI examinations performed before treatment and after the first treatment cycle. Participants were categorized into the very good partial response (VGPR) or better group and the less than VGPR group per the International Myeloma Working Group response criteria. ADC and rFF map metrics for predicting treatment response were compared using the Wilcoxon rank test, and the false discovery rate (FDR) was used to correct for multiple comparisons. Results A total of 23 participants (mean age, 65 years ± 11 [SD]; 13 men) were evaluated. There was no evidence of a difference in ADC metrics between the two responder groups after correcting for multiple comparisons. The rFF histogram changes between pretreatment MRI and MRI after the first treatment cycle (ΔrFF) that provided significant differences between the VGPR or better and less than VGPR groups were as follows: ΔrFF_10th Percentile (median, 0.5 [95% CI: 0, 1] vs -2.5 [95% CI: -5.1, 0.1], respectively), ΔrFF_90th Percentile (median, 2 [95% CI: 1, 6.8] vs -0.5 [95% CI: -1, 0]), ΔrFF_Mean (median, 3.4 [95% CI: 0.3, 7.6] vs -1.1 [95% CI: -1.8, -0.7]), and ΔrFF_Root Mean Squared (median, 3.2 [95% CI: 0.3, 6.1] vs -0.7 [95% CI: -1.3, -0.4]) (FDR-adjusted P = .03 for all), and the latter two also presented mean group increases in the VGPR or better group that were above the upper 95% CI limit for repeatability. Conclusion Very early changes in bone marrow relative fat fraction histogram metrics, calculated from MRI examination at baseline and after only one cycle of induction therapy, may help to predict very good partial response or better in participants with newly diagnosed multiple myeloma. © RSNA, 2022 Online supplemental material is available for this article.
Collapse
|
34
|
Pappas EP, Seimenis I, Kouris P, Theocharis S, Lampropoulos KI, Kollias G, Karaiskos P. Target localization accuracy in frame‐based stereotactic radiosurgery: Comparison between MR‐only and MR/CT co‐registration approaches. J Appl Clin Med Phys 2022; 23:e13580. [PMID: 35285583 PMCID: PMC9121047 DOI: 10.1002/acm2.13580] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Revised: 02/17/2022] [Accepted: 02/21/2022] [Indexed: 11/28/2022] Open
Abstract
Purpose In frame‐based Gamma Knife (GK) stereotactic radiosurgery two treatment planning workflows are commonly employed; one based solely on magnetic resonance (MR) images and the other based on magnetic resonance/computed tomography (MR/CT) co‐registered images. In both workflows, target localization accuracy (TLA) can be deteriorated due to MR‐related geometric distortions and/or MR/CT co‐registration uncertainties. In this study, the overall TLA following both clinical workflows is evaluated for cases of multiple brain metastases. Methods A polymer gel‐filled head phantom, having the Leksell stereotactic headframe attached, was CT‐imaged and irradiated by a GK Perfexion unit. A total of 26 4‐mm shots were delivered at 26 locations directly defined in the Leksell stereotactic space (LSS), inducing adequate contrast in corresponding T2‐weighted (T2w) MR images. Prescribed shot coordinates served as reference locations. An additional MR scan was acquired to implement the “mean image” distortion correction technique. The TLA for each workflow was assessed by comparing the radiation‐induced target locations, identified in MR images, with corresponding reference locations. Using T1w MR and CT images of 15 patients (totaling 81 lesions), TLA in clinical cases was similarly assessed, considering MR‐corrected data as reference. For the MR/CT workflow, both global and region of interest (ROI)‐based MR/CT registration approaches were studied. Results In phantom measurements, the MR‐corrected workflow demonstrated unsurpassed TLA (median offset of 0.2 mm) which deteriorated for MR‐only and MR/CT workflows (median offsets of 0.8 and 0.6 mm, respectively). In real‐patient cases, the MR‐only workflow resulted in offsets that exhibit a significant positive correlation with the distance from the MR isocenter, reaching 1.1 mm (median 0.6 mm). Comparable results were obtained for the MR/CT‐global workflow, although a maximum offset of 1.4 mm was detected. TLA was improved with the MR/CT‐ROI workflow resulting in median/maximum offsets of 0.4 mm/1.1 mm. Conclusions Subpixel TLA is achievable in all workflows. For the MR/CT workflow, a ROI‐based MR/CT co‐registration approach could considerably increase TLA and should be preferred instead of a global registration.
Collapse
|
35
|
Velonis M, Papanastasiou E, Hatziioannou K, Siountas A, Kamperis E, Papavasileiou P, Seimenis I. Dose optimisation of 2D x-ray image acquisition protocols in image-guided radiotherapy. Phys Med 2021. [DOI: 10.1016/s1120-1797(22)00402-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
36
|
Pappas E, Seimenis I, Kouris P, Lampropoulos K, Karaiskos P. Stereotactic radiosurgery for multiple brain metastases: does MR/CT co-registration improve target localization accuracy compared to the MR-only approach? Phys Med 2021. [DOI: 10.1016/s1120-1797(22)00374-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
|
37
|
Dellios D, Seimenis I, Pappas E, Karaiskos P, Kollias G. Evaluation of MR image correction schemes for accurate lesion localization in intracranial stereotactic radiosurgery. Phys Med 2021. [DOI: 10.1016/s1120-1797(22)00132-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
|
38
|
Busoni S, Bock M, Chmelik M, Colgan N, De Bondt T, Hanson LG, Israel M, Kugel H, Maieron M, Mazzoni LN, Seimenis I, Vestergaard P. ADDENDUM to EFOMP Policy statement No.14 "The role of the Medical Physicist in the management of safety within the magnetic resonance imaging environment: EFOMP recommendations". Phys Med 2021; 89:303-305. [PMID: 34492497 DOI: 10.1016/j.ejmp.2021.07.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
|
39
|
Morales Mojica CM, Velazco-Garcia JD, Pappas EP, Birbilis TA, Becker A, Leiss EL, Webb A, Seimenis I, Tsekos NV. A Holographic Augmented Reality Interface for Visualizing of MRI Data and Planning of Neurosurgical Procedures. J Digit Imaging 2021; 34:1014-1025. [PMID: 34027587 DOI: 10.1007/s10278-020-00412-3] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2020] [Revised: 12/06/2020] [Accepted: 12/18/2020] [Indexed: 10/21/2022] Open
Abstract
The recent introduction of wireless head-mounted displays (HMD) promises to enhance 3D image visualization by immersing the user into 3D morphology. This work introduces a prototype holographic augmented reality (HAR) interface for the 3D visualization of magnetic resonance imaging (MRI) data for the purpose of planning neurosurgical procedures. The computational platform generates a HAR scene that fuses pre-operative MRI sets, segmented anatomical structures, and a tubular tool for planning an access path to the targeted pathology. The operator can manipulate the presented images and segmented structures and perform path-planning using voice and gestures. On-the-fly, the software uses defined forbidden-regions to prevent the operator from harming vital structures. In silico studies using the platform with a HoloLens HMD assessed its functionality and the computational load and memory for different tasks. A preliminary qualitative evaluation revealed that holographic visualization of high-resolution 3D MRI data offers an intuitive and interactive perspective of the complex brain vasculature and anatomical structures. This initial work suggests that immersive experiences may be an unparalleled tool for planning neurosurgical procedures.
Collapse
|
40
|
Argyropoulos GD, Christidi F, Karavasilis E, Velonakis G, Antoniou A, Bede P, Seimenis I, Kelekis N, Douzenis A, Papakonstantinou O, Efstathopoulos E, Ferentinos P. Cerebro-cerebellar white matter connectivity in bipolar disorder and associated polarity subphenotypes. Prog Neuropsychopharmacol Biol Psychiatry 2021; 104:110034. [PMID: 32710925 DOI: 10.1016/j.pnpbp.2020.110034] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Revised: 07/08/2020] [Accepted: 07/12/2020] [Indexed: 12/12/2022]
Abstract
BACKGROUND The cerebellum has a crucial role in mood regulation. While cerebellar grey matter (GM) alterations have been previously reported in bipolar disorder (BD), cerebro-cerebellar white matter (WM) connectivity alterations and cerebellar GM profiles have not been characterised in the context of predominant polarity (PP) and onset polarity (OP) subphenotypes of BD patients which is the aim of the present study. METHODS Forty-two euthymic BD patients stratified for PP and OP and 42 healthy controls (HC) were included in this quantitative neuroimaging study to evaluate cerebellar GM patterns and cerebro-cerebellar WM connections. Diffusion tensor tractography was used to characterise afferent and efferent cerebro-cerebellar tract integrity. False discovery rate corrections were applied in post-hoc comparisons. RESULTS BD patients exhibited higher fractional anisotropy (FA) in fronto-ponto-cerebellar tracts bilaterally compared to HC. Subphenotype-specific FA profiles were identified within the BD cohort. Regarding PP subgroups, we found FA changes in a) left contralateral fronto-ponto-cerebellar tract (depressive-PP > HC) and b) contralateral/ipsilateral fronto-ponto-cerebellar tracts bilaterally (manic-PP > HC). Regarding OP subgroups, we observed FA changes in a) left/right contralateral fronto-ponto-cerebellar tracts (depressive-OP > HC) and b) all fronto-ponto-cerebellar, most parieto-ponto-cerebellar and right contralateral occipito-ponto-cerebellar tracts (manic-OP>HC). In general, greater and more widespread cerebro-cerebellar changes were observed in manic-OP patients than in depressive-OP patients compared to HC. Manic-OP showed higher FA compared to depressive-OP patients in several afferent WM tracts. No GM differences were identified between BD and HC and across BD subgroups. CONCLUSIONS Our findings highlight fronto-ponto-cerebellar connectivity alterations in euthymic BD. Polarity-related subphenotypes have distinctive cerebro-cerebellar WM signatures with potential clinical and pathobiological implications.
Collapse
|
41
|
Dellios D, Pappas EP, Seimenis I, Paraskevopoulou C, Lampropoulos KI, Lymperopoulou G, Karaiskos P. Evaluation of patient-specific MR distortion correction schemes for improved target localization accuracy in SRS. Med Phys 2020; 48:1661-1672. [PMID: 33230923 DOI: 10.1002/mp.14615] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2020] [Revised: 10/16/2020] [Accepted: 11/16/2020] [Indexed: 11/08/2022] Open
Abstract
PURPOSE This work aims at promoting target localization accuracy in cranial stereotactic radiosurgery (SRS) applications by focusing on the correction of sequence-dependent (also patient induced) magnetic resonance (MR) distortions at the lesion locations. A phantom-based quality assurance (QA) methodology was developed and implemented for the evaluation of three distortion correction techniques. The same approach was also adapted to cranial MR images used for SRS treatment planning purposes in single or multiple brain metastases cases. METHODS A three-dimensional (3D)-printed head phantom was filled with a 3D polymer gel dosimeter. Following treatment planning and dose delivery, volumes of radiation-induced polymerization served as hypothetical lesions, offering adequate MR contrast with respect to the surrounding unirradiated areas. T1-weighted (T1w) MR imaging was performed at 1.5 T using the clinical scanning protocol for SRS. Additional images were acquired to implement three distortion correction methods; the field mapping (FM), mean image (MI) and signal integration (SI) techniques. Reference lesion locations were calculated as the averaged centroid positions of each target identified in the forward and reverse read gradient polarity MRI scans. The same techniques and workflows were implemented for the correction of contrast-enhanced T1w MR images of 10 patients with a total of 27 brain metastases. RESULTS All methods employed in the phantom study diminished spatial distortion. Median and maximum distortion magnitude decreased from 0.7 mm (2.10 ppm) and 0.8 mm (2.36 ppm), respectively, to <0.2 mm (0.61 ppm) at all target locations, using any of the three techniques. Image quality of the corrected images was acceptable, while contrast-to-noise ratio slightly increased. Results of the patient study were in accordance with the findings of the phantom study. Residual distortion in corrected patient images was found to be <0.3 mm in the vast majority of targets. Overall, the MI approach appears to be the most efficient correction method from the three investigated. CONCLUSIONS In cranial SRS applications, patient-specific distortion correction at the target location(s) is feasible and effective, despite the expense of longer imaging time since additional MRI scan(s) need to be performed. A phantom-based QA methodology was developed and presented to reassure efficient implementation of correction techniques for sequence-dependent spatial distortion.
Collapse
|
42
|
Psarras M, Ploussi A, Carinou E, Brountzos E, Spiliopoulos SC, Palialexis K, Kelekis A, Filippiadis D, Seimenis I, Efstathopoulos EP. RADIATION DOSES TO THE EYE LENS AND FOREHEAD OF INTERVENTIONAL RADIOLOGISTS: HOW HIGH AND ON WHAT GROUNDS? RADIATION PROTECTION DOSIMETRY 2020; 190:150-157. [PMID: 32626896 DOI: 10.1093/rpd/ncaa097] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/05/2020] [Revised: 05/05/2020] [Accepted: 06/10/2020] [Indexed: 02/05/2023]
Abstract
The aim of the study was to measure and evaluate the radiation dose to the eye lens and forehead of interventional radiologists (IRs). The study included 96 procedures (lower-limb percutaneous transluminal angioplasties, embolisations/chemoembolisations and vertebroplasties) performed by 6 IRs. A set of seven thermoluminescence dosemeters was allocated to each physician. The highest dose per procedure was found for the left eye lens of the primary operator in vertebroplasties (1576 μSv). Left and right eye doses were linearly correlated to left and right forehead doses, respectively. A workload-based estimation of the annual dose to participating IRs revealed that the occupational dose limit for the eye lens can be easily exceeded. The left eye dose of ΙRs must be routinely monitored on a personalised basis. Τhe left eye dose measurement provides a reliable assessment of the ipsilateral forehead dose, along with valid estimations for the right eye and right forehead doses.
Collapse
|
43
|
Gkotsis DE, Gotsis ED, Lymperopoulou G, Karaiskos P, Seimenis I. Determination of the R 2* relaxation rate constant for estimating hepatic iron concentration: A customized approach that considers liver fat infiltration. Phys Med 2020; 76:150-158. [PMID: 32679410 DOI: 10.1016/j.ejmp.2020.06.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/10/2020] [Revised: 06/05/2020] [Accepted: 06/23/2020] [Indexed: 10/23/2022] Open
Abstract
PURPOSE Α customized approach to determine R2* relaxation rate for hepatic iron concentration (HIC) estimation is presented, and is evaluated in the context of concurrent liver fat infiltration. METHODS The proposed method employs a customized acquisition protocol, featuring a 16-echo, gradient-echo sequence, and a bi-exponential least squares fitting that considers baseline noise and uses a cosine function to correct for fat-induced signal oscillation. 193 patients with wide-ranging HIC and liver fat fraction (FF) were imaged at 1.5 T. In severely iron-overload patients, a four-echo train technique was applied to enforce all 16 echoes in the 1.2-4.0 ms range. Acquired data were compared to corresponding results obtained with the IDEAL IQ method. RESULTS Techniques employed to counter the rapid signal decay in iron-overloaded liver, such as the offset and the truncation methods, have to be combined with the appropriate calibration curve to provide reliable HIC estimation. When high grade steatosis and siderosis co-exist, fat-suppression may downgrade siderosis. A high correlation was observed between data obtained with the proposed technique and the IDEAL IQ method, except from the high R2* region. However, systematic differences were detected. In the concurrent presence of high FF and non-severe iron overload, it is postulated that the bi-exponential model may attribute patient siderosis grading more accurately than IDEAL IQ, while simultaneously providing reliable FF estimation. CONCLUSIONS The proposed approach is widely available and seems capable of providing reliable R2* measurements regardless of liver steatosis grading, whilst it succeeds in averting significant R2* underestimation in severely iron-overloaded liver.
Collapse
|
44
|
Intzes S, Symeonidou M, Zagoridis K, Bezirgiannidou Z, Pentidou A, Vrachiolias G, Seimenis I, Kotsianidis I, Spanoudakis E. Socioeconomic Status Is an Independent Prognostic Factor for Overall Survival in Patients With Multiple Myeloma: Real-World Data From a Cohort of 223 Patients. CLINICAL LYMPHOMA MYELOMA & LEUKEMIA 2020; 20:704-711. [PMID: 32653455 DOI: 10.1016/j.clml.2020.05.013] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Revised: 05/05/2020] [Accepted: 05/11/2020] [Indexed: 02/07/2023]
Abstract
INTRODUCTION Socioeconomic status (SES) has been shown to be a prognostic factor for overall survival in a variety of hematologic malignancies, especially for patients who require continuous care such as those with multiple myeloma (MM). PATIENTS AND METHODS We retrospectively collected data from 223 patients with symptomatic MM diagnosed and treated in our department from January 2005 to December 2019. The modified Kuppuswamy scale, slightly modified, was used for the SES assessment. The Kaplan-Meier estimator of survival and Cox regression analysis were used. RESULTS In our cohort of 223 patients with MM, low SES was an independent poor prognostic factor for overall survival (OS), in addition to higher International Staging System stage and high-risk cytogenetics (hazard ratio for low SES on Cox regression analysis, 2.092; 95% confidence interval [CI], 1.36-3.2; log-rank P = .000). Patients with low SES had inferior survival compared with the whole patient cohort (median OS: low SES, 28 months; 95% CI, 18-37.9; high SES, 68 months; 95% CI, 55.6-80.4; log-rank P = .000). The low SES effect on OS was more evident for the elderly patients who were not transplant eligible and in those with a diagnosis of MM International Staging System stage I. The effect of low SES on OS was attenuated by time, and ethnic origin had no effect on OS. CONCLUSIONS The results of the present study have shown that low SES is an independent poor prognostic factor for survival of patients with MM.
Collapse
|
45
|
Parthimos TP, Karavasilis E, Rankin KP, Seimenis I, Leftherioti K, Papanicolaou AC, Miller B, Papageorgiou SG, Papatriantafyllou JD. The Neural Correlates of Impaired Self-Monitoring Among Individuals With Neurodegenerative Dementias. J Neuropsychiatry Clin Neurosci 2020; 31:201-209. [PMID: 30605361 DOI: 10.1176/appi.neuropsych.17120349] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
Self-monitoring is a crucial component of human empathy and necessary for the formation and repair of social relations. Several studies have brought to light possible neuronal substrates associated with self-monitoring, but the information that they have provided is inconclusive. The authors, therefore, studied a large group of patients with dementia to assess what brain structures are necessary for the self-monitoring function.Methods: Seventy-seven patients with dementia of various types were screened using voxel-based morphometry to assess possible volume reduction in the brain structures of patients with self-monitoring problems, and the decrease of socioemotional expressiveness and modification of self-presentation was estimated using the Revised Self-Monitoring Scale. Regression analysis was employed to investigate the correlation between gray matter loss and deficient self-monitoring.Results: The socioemotional expressiveness scores were associated with decreased gray matter volume in the right olfactory cortex, inferior frontal gyrus, superior temporal pole, parahippocampal gyrus, insula, and medial temporal gyrus bilaterally. Self-presentation scores were associated with bilateral gray matter volume reduction in the olfactory cortex, insula, rectus gyrus and inferior frontal gyrus, right superior temporal pole, and parahippocampal gyrus, as well as the left medial temporal gyrus and anterior superior frontal gyrus.Conclusions: These results suggest that patients with dementia present decreased ability of self-monitoring, probably due to impaired insula and orbitofrontal cortex and their disconnection from structures of the salience network.
Collapse
|
46
|
Koutsojannis C, Andrikopoulos A, Seimenis I, Adamopoulos A. MAGNETO-THERAPY IN PHYSIOTHERAPY UNITS: INTRODUCTION OF QUALITY CONTROL PROCEDURE DUE TO LACK OF MAINTENANCE. RADIATION PROTECTION DOSIMETRY 2019; 185:532-541. [PMID: 31329986 DOI: 10.1093/rpd/ncz049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2019] [Revised: 03/12/2019] [Accepted: 03/18/2019] [Indexed: 06/10/2023]
Abstract
Rehabilitation practice for many patients consisting of a combined use of magneto therapy resulting emission of low frequency magnetic fields to the patient, elicit concerns about occupational exposure to electromagnetic radiation (EMR) for the operators. The time extended use of the device periodically leads to mechanical failures or troubleshooting of the machine which, in most cases, are not perceived by the operator of the device. All device's efficient functionality have a major impact on the completion of the treatment procedure in a large percentage of specific clinical conditions. If the device's operating condition is technically out of order or in a mode of over-activity, operators are mainly seeking solutions by reviewing the clinical case of the patient. This eliminates their contribution during the primary therapeutic plan or increases the treatment sessions. In this work, an extended survey is presented including 75 physiotherapy centres concerning usability and maintenance issues of magneto therapy devices throughout Greek territory combined with extended measurements of Electromagnetic Radiation in the unit room were performed. Physiotherapists' perceptions revealed lack of technical support, maintenance and safe use of magneto therapy devices that extract auxiliary observations upon their clinical practice routines. Additionally safety measurements have not revealed field strengths over International Reference Levels which could result health risks for users and coexisting patients. The pilot survey that conducted in Attica and Western Greece confirms that magnetic fields strength that are measured are in accordance with the statutory legislation but will, at the same time, revealed lack of maintenance of the devices. Deficiency in topics such as proper equipment function will necessitate the creation of quality safety protocols, concerning the use of magneto-therapy, with the main aim the improvement of treatment procedures for the higher performance of therapeutic rehabilitation services to patients. Finally in this work, the proposal of a QC protocol for magnetotherapy devices is proposed for evaluation.
Collapse
|
47
|
Christidi F, Karavasilis E, Rentzos M, Velonakis G, Zouvelou V, Xirou S, Argyropoulos G, Papatriantafyllou I, Pantolewn V, Ferentinos P, Kelekis N, Seimenis I, Evdokimidis I, Bede P. Neuroimaging data indicate divergent mesial temporal lobe profiles in amyotrophic lateral sclerosis, Alzheimer's disease and healthy aging. Data Brief 2019; 28:104991. [PMID: 31921944 PMCID: PMC6948121 DOI: 10.1016/j.dib.2019.104991] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2019] [Accepted: 12/05/2019] [Indexed: 12/12/2022] Open
Abstract
A prospective, standardised neuroimaging protocol was implemented to characterise mesial temporal lobe pathology in amyotrophic lateral sclerosis, Alzheimer's disease and healthy controls focusing on the evaluation of interconnected white and grey matter structures. “Hippocampal pathology in Amyotrophic Lateral Sclerosis: selective vulnerability of subfields and their associated projections” [1]. High-resolution diffusion tensor and structural imaging data were acquired on a 3 T MRI platform using standardised sequence parameters. The integrity of the fornix and the perforant pathway was assessed by tractography, to provide fractional anisotropy, axial diffusivity and radial diffusivity measures. Quantitative structural imaging was used to estimate the total intracranial volume, total hippocampal volumes and hippocampal subfield volumes for each participant. Raw white- and grey-matter measures, demographic and clinical data are available online at ‘Mendeley Data’. Amyotrophic lateral sclerosis and Alzheimer's disease exhibit divergent hippocampal profiles.
Collapse
|
48
|
Christidi F, Karavasilis E, Rentzos M, Velonakis G, Zouvelou V, Xirou S, Argyropoulos G, Papatriantafyllou I, Pantolewn V, Ferentinos P, Kelekis N, Seimenis I, Evdokimidis I, Bede P. Hippocampal pathology in amyotrophic lateral sclerosis: selective vulnerability of subfields and their associated projections. Neurobiol Aging 2019; 84:178-188. [DOI: 10.1016/j.neurobiolaging.2019.07.019] [Citation(s) in RCA: 48] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2019] [Revised: 07/10/2019] [Accepted: 07/10/2019] [Indexed: 12/29/2022]
|
49
|
Pappas E, Kalaitzakis G, Boursianis T, Zoros E, Zourari K, Pappas EP, Makris D, Seimenis I, Efstathopoulos E, Maris TG. Dosimetric performance of the Elekta Unity MR-linac system: 2D and 3D dosimetry in anthropomorphic inhomogeneous geometry. ACTA ACUST UNITED AC 2019; 64:225009. [DOI: 10.1088/1361-6560/ab52ce] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
|
50
|
Pappas E, Kalaitzakis G, Seimenis I, Pappas E, Maris T. Clinical IMRT Irradiation with an MR-Linac System: A Methodology and Preliminary Results for a Real-Time Verification of Spatial Accuracy of Dose Delivery. Int J Radiat Oncol Biol Phys 2019. [DOI: 10.1016/j.ijrobp.2019.06.565] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|