26
|
Baltes P, Bota M, Albert J, Philipper M, Hörster HG, Hagenmüller F, Steinbrück I, Jakobs R, Bechtler M, Hartmann D, Neuhaus H, Charton JP, Mayershofer R, Hohn H, Rösch T, Groth S, Nowak T, Wohlmuth P, Keuchel M. PillCamColon2 after incomplete colonoscopy - A prospective multicenter study. World J Gastroenterol 2018; 24:3556-3566. [PMID: 30131662 PMCID: PMC6102503 DOI: 10.3748/wjg.v24.i31.3556] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2018] [Revised: 07/18/2018] [Accepted: 07/21/2018] [Indexed: 02/06/2023] Open
Abstract
AIM To evaluate the ability of PillCamColon2 to visualize colonic segments missed by incomplete optical colonoscopy (OC) and to assess the diagnostic yield.
METHODS This prospective multicentre study included 81 patients from nine centres who underwent second-generation colon capsule endoscopy (CCE) following incomplete OC performed by an experienced gastroenterologist (> 1000 colonoscopies). Patients with stenosis were excluded. According to patient preferences, CCE was performed the following day (protocol A) after staying on clear liquids and 0.75 L Moviprep in the morning or within 30 d after new split-dose Moviprep (protocol B). Boosts consisted of 0.75 L and 0.25 L Moviprep, and phospho-soda was given as a rescue if the capsule was not excreted after seven hours.
RESULTS Seventy-four patients were analysed (51% of them in group A; 49% in group B). Bowel cleansing was adequate in 67% of cases, and CCE could visualize colonic segments missed by incomplete colonoscopy in 90% of patients under protocol A and 97% of patients under protocol B (P = 0.35, n.s.). Significant polyps including adenocarcinoma were detected in 24% of cases. Detection rates for all polyps and significant polyps per patient were similar in both protocols. Polyps were found predominantly in the right colon (86%) in segments that were not reached by OC. Extracolonic findings - such as reflux esophagitis, suspected Barrett esophagus, upper GI-bleeding, gastric polyps, gastric erosions and angiectasia - were detected in eight patients. PillCamColon2 capsule was retained in the ileum of one patient (1.4%) without symptoms and removed during an uneventful resection for unknown Crohn’s disease that was diagnosed as the cause of anemia, which was the indication for colonoscopy. CCE was well tolerated. One patient suffered from self-limiting vomiting after consuming the phospho-soda.
CONCLUSION Second-generation CCE using a low-volume preparation is useful after incomplete OC, and it allows for the detection of additional relevant findings, but cleansing efficiency could be improved.
Collapse
|
27
|
Lay HS, Cummins G, Cox BF, Qiu Y, Turcanu MV, McPhillips R, Connor C, Gregson R, Clutton E, Desmulliez MPY, Cochran S. In-Vivo Evaluation of Microultrasound and Thermometric Capsule Endoscopes. IEEE Trans Biomed Eng 2018; 66:632-639. [PMID: 29993482 DOI: 10.1109/tbme.2018.2852715] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Clinical endoscopy and colonoscopy are commonly used to investigate and diagnose disorders in the upper gastrointestinal tract and colon, respectively. However, examination of the anatomically remote small bowel with conventional endoscopy is challenging. This and advances in miniaturization led to the development of video capsule endoscopy (VCE) to allow small bowel examination in a noninvasive manner. Available since 2001, current capsule endoscopes are limited to viewing the mucosal surface only due to their reliance on optical imaging. To overcome this limitation with submucosal imaging, work is under way to implement microultrasound (μUS) imaging in the same form as VCE devices. This paper describes two prototype capsules, termed Sonocap and Thermocap, which were developed respectively to assess the quality of μUS imaging and the maximum power consumption that can be tolerated for such a system. The capsules were tested in vivo in the oesophagus and small bowel of porcine models. Results are presented in the form of μUS B-scans as well as safe temperature readings observed up to 100 mW in both biological regions. These results demonstrate that acoustic coupling and μUS imaging can be achieved in vivo in the lumen of the bowel and the maximum power consumption that is possible for miniature μUS systems.
Collapse
|
28
|
Ribaldone DG, Bruno M, Solidoro P, De Angelis C. Real time visualization may be advisable to exclude aspiration in patients undergoing capsule endoscopy examination. REVISTA ESPANOLA DE ENFERMEDADES DIGESTIVAS 2017; 109:878-879. [PMID: 29152989 DOI: 10.17235/reed.2017.5244/2017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Capsule endoscopy (CE) is currently considered as a first line diagnostic tool for small bowel examination. Some patients find swallowing the capsule difficult. However, capsule aspiration is relatively uncommon and is only reported in isolated cases. The majority of these cases are male (39/41; 95.1%) with an age ranging from 56-93 years and only 4 (9.8%) patients had a recorded history of dysphagia. Twenty-four out of 41 (58.5%) patients experienced symptoms of capsule aspiration. The aspiration self-resolved in 11/41 patients and the CE was retrieved during bronchoscopy in the other cases. We present the case of a 75 year old man with a history of chronic anemia who was referred for CE.
Collapse
|
29
|
Dimas G, Spyrou E, Iakovidis DK, Koulaouzidis A. Intelligent visual localization of wireless capsule endoscopes enhanced by color information. Comput Biol Med 2017; 89:429-440. [PMID: 28886480 DOI: 10.1016/j.compbiomed.2017.08.029] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2017] [Revised: 08/07/2017] [Accepted: 08/27/2017] [Indexed: 12/28/2022]
|
30
|
Chitul A, Voiosu AM, Marinescu M, Caraiola S, Nicolau A, Badea GC, Pârvu MI, Ionescu RA, Mateescu BR, Voiosu MR, Băicuş CR, Rimbaş M. Different effects of anti-TNF-alpha biologic drugs on the small bowel macroscopic inflammation in patients with ankylosing spondylitis. ACTA ACUST UNITED AC 2017; 55:44-52. [PMID: 28103201 DOI: 10.1515/rjim-2017-0001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2016] [Indexed: 01/12/2023]
Abstract
BACKGROUND & AIMS Considering the ability of anti-TNF alpha drugs to lower the burden intestinal inflammation in patients with inflammatory bowel disease (IBD), and the similarity between IBD and ankylosing spondylitis (AS) regarding inflammatory intestinal involvement, we aimed to investigate the impact of anti-TNF alpha biologic therapy on subclinical intestinal inflammation in AS patients. METHODS Between January 2008 and December 2013, 38 AS patients and 23 controls were enrolled in the study and investigated with small bowel videocapsule endoscopy examination and ileocolonoscopy. Each tertile of the small bowel (proximal, mid and distal) was assessed by calculating the Lewis score based on the image stream. RESULTS The Lewis scores were significantly higher in the AS group compared to controls (580.9 ± 818 vs. 81 ± 121, p<0.001). 16 patients (42.1%) were on anti-TNF alpha therapy (Adalimumab (n = 5), Infliximab (n = 5) or Etanercept (n = 6)).31.3% of them used NSAIDs simultaneously, compared with 77.3% of the other patients (p<0.01). Their Lewis scores were lower compared to the other patients for the entire small bowel (306 ± 164 vs. 790 ± 1038, p = 0.015), its proximal and distal tertiles (238 ± 154 vs. 560 ± 543, p = 0.021, and 140 ± 189 vs. 300 ± 220, p = 0.027, respectively). The Lewis score was also lower in patients receiving Adalimumab/Infliximab compared to those on Etanercept for the entire bowel and its distal tertile (262 ± 165 vs. 380 ± 148, p = 0.069 and 62 ± 101 vs. 273 ± 236, p = 0.060, respectively). CONCLUSION Anti-TNF alpha therapy in patients with AS reduces the subclinical intestinal inflammation, but the magnitude seems to depend upon the class anti-TNF alpha agent used (Clinical Trials. gov NCT00768950).
Collapse
|
31
|
Alsunaydih FN, Redoute JM, Yuce MR. A wireless capsule endoscopy steering mechanism using magnetic field platform. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2017; 2017:3036-3039. [PMID: 29060538 DOI: 10.1109/embc.2017.8037497] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
In this paper, a new steering mechanism for wireless capsule devices is presented. The proposed system consists of a platform generating a magnetic field to direct and control the motion of a capsule. The platform contains an upper and a lower set of electromagnets. A permanent magnet is implanted inside the capsule to initiate the movement, which is set by the magnetic field delivered by the electromagnets. The total magnetic field at the capsule's location is the sum of the contributions of each electromagnet. An experimental setup has been designed for testing and comparing between the performance of the capsule mobility in practice and simulations.
Collapse
|
32
|
Liu H, Shao Q, Fang X. Modeling and Optimization of Class-E Amplifier at Subnominal Condition in a Wireless Power Transfer System for Biomedical Implants. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2017; 11:35-43. [PMID: 27323372 DOI: 10.1109/tbcas.2016.2538320] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
For the class-E amplifier in a wireless power transfer (WPT) system, the design parameters are always determined by the nominal model. However, this model neglects the conduction loss and voltage stress of MOSFET and cannot guarantee the highest efficiency in the WPT system for biomedical implants. To solve this problem, this paper proposes a novel circuit model of the subnominal class-E amplifier. On a WPT platform for capsule endoscope, the proposed model was validated to be effective and the relationship between the amplifier's design parameters and its characteristics was analyzed. At a given duty ratio, the design parameters with the highest efficiency and safe voltage stress are derived and the condition is called 'optimal subnominal condition.' The amplifier's efficiency can reach the highest of 99.3% at the 0.097 duty ratio. Furthermore, at the 0.5 duty ratio, the measured efficiency of the optimal subnominal condition can reach 90.8%, which is 15.2% higher than that of the nominal condition. Then, a WPT experiment with a receiving unit was carried out to validate the feasibility of the optimized amplifier. In general, the design parameters of class-E amplifier in a WPT system for biomedical implants can be determined with the proposed optimization method in this paper.
Collapse
|
33
|
Zhang W, Jin YT, Guo X, Su JH, You SP. Design of an autofocus capsule endoscope system and the corresponding 3D reconstruction algorithm. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2016; 33:1970-1977. [PMID: 27828100 DOI: 10.1364/josaa.33.001970] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
A traditional capsule endoscope can only take 2D images, and most of the images are not clear enough to be used for diagnosing. A 3D capsule endoscope can help doctors make a quicker and more accurate diagnosis. However, blurred images negatively affect reconstruction accuracy. A compact, autofocus capsule endoscope system is designed in this study. Using a liquid lens, the system can be electronically controlled to autofocus, and without any moving elements. The depth of field of the system is in the 3-100 mm range and its field of view is about 110°. The images captured by this optical system are much clearer than those taken by a traditional capsule endoscope. A 3D reconstruction algorithm is presented to adapt to the zooming function of our proposed system. Simulations and experiments have shown that more feature points can be correctly matched and a higher reconstruction accuracy can be achieved by this strategy.
Collapse
|
34
|
Ohta H, Izumi S, Yoshimoto M. A more acceptable endoluminal implantation for remotely monitoring ingestible sensors anchored to the stomach wall. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2015:4089-92. [PMID: 26737193 DOI: 10.1109/embc.2015.7319293] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Several types of implant devices have been proposed and introduced into healthcare and telemedicine systems for monitoring physiological parameters, sometimes for very long periods of time. To our disappointment, most of the devices are implanted invasively and by surgery. We often have to surgically remove such devices after they have finished their mission or before the battery becomes worn out. Wearable devices have the possibility to become new modalities for monitoring vital parameters less-invasively. However, for round-the-clock monitoring of data from sensors over long periods of time, it would be better to put them inside the body to avoid causing inconvenience to patients in their daily lives. This study tested a less invasive endoluminal approach and innovative tools (developed during our research into therapeutic capsule endoscopy) for remotely anchoring ingestible sensors to the stomach wall. Preliminary investigations are also described about wireless communication (NFC, ZigBee, and Bluetooth) for low power consumption and inductive extracorporeal power feeding wirelessly to the circuits in a phantom lined with swine gastric mucosa. Electrocardiogram and pH were monitored and those parameters were successfully transmitted by wireless communication ICs to the Internet via a portable device.
Collapse
|
35
|
Leung BHK, Poon CCY, Zhang R, Zheng Y, Chan CKW, Chiu PWY, Lau JYW, Sung JJY. A Therapeutic Wireless Capsule for Treatment of Gastrointestinal Haemorrhage by Balloon Tamponade Effect. IEEE Trans Biomed Eng 2016; 64:1106-1114. [PMID: 27416587 DOI: 10.1109/tbme.2016.2591060] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
OBJECTIVE Wireless capsule endoscope (WCE) is a revolutionary approach to diagnose small bowel pathologies. Currently available WCEs are mostly passive devices with image capturing function only, while on-going efforts have been placed on robotizing WCEs or to enhance them with therapeutic functions. In this paper, the authors present a novel inflatable WCE for haemostasis in the gastrointestinal (GI) tracts by balloon tamponade effect. METHODS The proposed wireless capsule consists of a balloon that can be inflated using the endothermic reaction of acid and base. When the balloon reached a precalculated pressure level, it is able to stop at a bleeding site in the bowel, and achieve haemostasis by tamponade effect. The prototype is 14 mm in diameter, with three sections of 13, 35, and 12 mm in length, respectively. The three sections are linked together with flexible joints and enclosed in a silicone balloon. The prototypes were tested in ex vivo porcine intestine models. RESULTS In the ten ex vivo trials conducted, the inflatable wireless capsule achieved average balloon pressure of 46.0 mmHg and withstood average maximum longitudinal pulling force at 1.46 N. An in vivo study was carried out as a proof-of-concept for treating bleeding in a porcine model. The proposed inflatable WCE succeeded in the animal test by controlling haemostasis within 5 min. No rebleeding was observed in the next 20 min. CONCLUSION The results suggested that the inflatable capsule with a real-time bleeding detection algorithm can be implemented. Moreover, the proposed inflatable WCE prototype can achieve haemorrhage control in the lower GI. SIGNIFICANCE To our best knowledge, this is the first study that demonstrated the potential to treat GI haemorrhage by an inflatable WCE. The proposed capsule enables the development of a closed-loop system based on a body sensor network to provide early treatment of GI bleeding for p-medicine.
Collapse
|
36
|
Liu L, Towfighian S, Hila A. A Review of Locomotion Systems for Capsule Endoscopy. IEEE Rev Biomed Eng 2016; 8:138-51. [PMID: 26292162 DOI: 10.1109/rbme.2015.2451031] [Citation(s) in RCA: 57] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Wireless capsule endoscopy for gastrointestinal (GI) tract is a modern technology that has the potential to replace conventional endoscopy techniques. Capsule endoscopy is a pill-shaped device embedded with a camera, a coin battery, and a data transfer. Without a locomotion system, this capsule endoscopy can only passively travel inside the GI tract via natural peristalsis, thus causing several disadvantages such as inability to control and stop, and risk of capsule retention. Therefore, a locomotion system needs to be added to optimize the current capsule endoscopy. This review summarizes the state-of-the-art locomotion methods along with the desired locomotion features such as size, speed, power, and temperature and compares the properties of different methods. In addition, properties and motility mechanisms of the GI tract are described. The main purpose of this review is to understand the features of GI tract and diverse locomotion methods in order to create a future capsule endoscopy compatible with GI tract properties.
Collapse
|
37
|
Ara P, Cheng S, Heimlich M, Dutkiewicz E. Investigation of in-body path loss in different human subjects for localization of capsule endoscope. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2015:5461-4. [PMID: 26737527 DOI: 10.1109/embc.2015.7319627] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Recent developments in capsule endoscopy have highlighted the need for accurate techniques to estimate the location of a capsule endoscope. A highly accurate location estimation of a capsule endoscope in the gastrointestinal (GI) tract in the range of several millimeters is a challenging task. This is mainly because the radio-frequency signals encounter high loss and a highly dynamic channel propagation environment. Therefore, an accurate path-loss model is required for the development of accurate localization algorithms. This paper presents an in-body path-loss model for the human abdomen region at 2.4 GHz frequency. To develop the path-loss model, electromagnetic simulations using the Finite-Difference Time-Domain (FDTD) method were carried out on two different anatomical human models. A mathematical expression for the path-loss model was proposed based on analysis of the measured loss at different capsule locations inside the small intestine. The proposed path-loss model is a good approximation to model in-body RF propagation, since the real measurements are quite infeasible for the capsule endoscopy subject.
Collapse
|
38
|
|
39
|
Ou-Yang M, Jeng WD, Lai CC, Wu HM, Lin JH. Color calibration of swine gastrointestinal tract images acquired by radial imaging capsule endoscope. JOURNAL OF BIOMEDICAL OPTICS 2016; 21:15010. [PMID: 26803670 DOI: 10.1117/1.jbo.21.1.015010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2015] [Accepted: 12/30/2015] [Indexed: 06/05/2023]
|
40
|
Santos-Antunes J, Cardoso H, Lopes S, Marques M, Nunes ACR, Macedo G. Capsule enteroscopy is useful for the therapeutic management of Crohn’s disease. World J Gastroenterol 2015; 21:12660-12666. [PMID: 26640343 PMCID: PMC4658621 DOI: 10.3748/wjg.v21.i44.12660] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/24/2015] [Revised: 06/30/2015] [Accepted: 08/31/2015] [Indexed: 02/06/2023] Open
Abstract
AIM: To analyze therapeutic changes in Crohn’s disease (CD) patients following video capsule endoscopy (VCE) and to assess the usefulness of Lewis score and the Patency Capsule.
METHODS: Patency Capsule was performed in every patient that had indication for VCE, and those with negative patency did not undergo VCE. Patients with established CD that underwent VCE between January 2011 and February 2014 were selected for this study; those with suspected CD were excluded, independent of VCE results, since our purpose was to address differences in therapeutic regimen in CD patients before and after VCE. Patients with inconclusive VCE were also excluded. Patients had to be free of non-steroidal anti-inflammatories for at least 1 mo. Those patients who met these criteria were allocated into one of three groups: Staging group (asymptomatic CD patients that underwent VCE for staging of CD), Flare group (patients with active CD), or Post-op group (CD patients evaluated for post-operative recurrence). Lewis score was calculated for every VCE procedure. Statistical analysis was performed to address the impact of VCE findings on the therapeutic management of CD patients and to evaluate the utility of the Lewis score.
RESULTS: From a total of 542 VCEs, 135 were performed in patients with CD. Patency capsule excluded nearly 25% of the patients who were supposed to undergo VCE. No videocapsule retention during VCE was reported. From these 135 patients, 29 were excluded because CD diagnosis was not established at the time of VCE. Therefore, a total of 106 patients were included in the final analysis. From these, the majority were in the Staging group (n = 73, 69%), and the remaining were in the Flare (n = 23, 22%) or Post-op (n = 10, 9%) group. Median time between diagnosis and VCE was 5.5 years. Overall, VCE determined changes in the treatment of 40% of patients: only 21% remained free of immunosuppressors after VCE compared to 44% before VCE (P < 0.001). The differences in therapy before and after VCE achieved statistical significance in the Staging and Flare groups. In addition, patients were significantly different when stratified regarding time since diagnosis to the date of VCE. A higher Lewis score was associated with therapeutic modifications (P < 0.0001); where a score higher than 1354 was related to 90% probability of changing therapy [area under the receiver operative characteristic (AUROC) 0.80 (95%CI: 0.69-0.88)].
CONCLUSION: VCE significantly changed the therapeutic management of CD patients, even in those with long-term disease. Systematic use of Patency capsule allowed for no videocapsule retention.
Collapse
|
41
|
Slawinski PR, Obstein KL, Valdastri P. Capsule endoscopy of the future: What's on the horizon? World J Gastroenterol 2015; 21:10528-41. [PMID: 26457013 PMCID: PMC4588075 DOI: 10.3748/wjg.v21.i37.10528] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/27/2015] [Revised: 06/22/2015] [Accepted: 08/31/2015] [Indexed: 02/06/2023] Open
Abstract
Capsule endoscopes have evolved from passively moving diagnostic devices to actively moving systems with potential therapeutic capability. In this review, we will discuss the state of the art, define the current shortcomings of capsule endoscopy, and address research areas that aim to overcome said shortcomings. Developments in capsule mobility schemes are emphasized in this text, with magnetic actuation being the most promising endeavor. Research groups are working to integrate sensor data and fuse it with robotic control to outperform today's standard invasive procedures, but in a less intrusive manner. With recent advances in areas such as mobility, drug delivery, and therapeutics, we foresee a translation of interventional capsule technology from the bench-top to the clinical setting within the next 10 years.
Collapse
|
42
|
Tseng YC, Hsu HC, Han P, Tsai CM. Color multiplexing method to capture front and side images with a capsule endoscope. APPLIED OPTICS 2015; 54:E241-E248. [PMID: 26479660 DOI: 10.1364/ao.54.00e241] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
This paper proposes a capsule endoscope (CE), based on color multiplexing, to simultaneously record front and side images. Only one lens associated with an X-cube prism is employed to catch the front and side view profiles in the CE. Three color filters and polarizers are placed on three sides of an X-cube prism. When objects locate at one of the X-cube's three sides, front and side view profiles of different colors will be caught through the proposed lens and recorded at the color image sensor. The proposed color multiplexing CE (CMCE) is designed with a field of view of up to 210 deg and a 180 lp/mm resolution under f-number 2.8 and overall length 13.323 mm. A ray-tracing simulation in the CMCE with the color multiplexing mechanism verifies that the CMCE not only records the front and side view profiles at the same time, but also has great image quality at a small size.
Collapse
|
43
|
Yee K. Appendicitis following capsule endoscopy. BMJ Case Rep 2015; 2015:bcr-2015-211182. [PMID: 26336184 DOI: 10.1136/bcr-2015-211182] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022] Open
Abstract
A 19-year-old woman presented to the emergency department with abdominal pain 10 h after ingesting a capsule endoscope. The pain subsequently localised to the right iliac fossa with guarding and cough/percussion tenderness. Follow-up pelvic ultrasound showed a tender non-compressible appendix consistent with appendicitis. The patient underwent a laparoscopic appendectomy with good recovery. This report describes an unusual presentation of appendicitis following ingestion of a capsule endoscope.
Collapse
|
44
|
Ciuti G, Tognarelli S, Verbeni A, Menciassi A, Dario P. Intraoperative bowel cleansing tool in active locomotion capsule endoscopy. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2013:4843-6. [PMID: 24110819 DOI: 10.1109/embc.2013.6610632] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Capsule endoscopy (CE) can be considered an example of "disruptive technology" since it represents a bright alternative to traditional diagnostic methodologies. If compared with traditional endoscopy, bowel cleansing procedure in CE becomes of greater importance, due to the impossibility to intraoperatively operate on unclean gastrointestinal tract areas. Considering the promising results and benefits obtained in the field of CE for gastrointestinal diagnosis and intervention, the authors approached the bowel cleansing issue with the final aim to propose an innovative and easy-to-use intraoperative cleansing system to be applied to an active locomotion softly-tethered capsule device, already developed by the authors. The system, that has to be intended as an additional tool for intraoperatively cleansing procedure of the colonic tract, is composed by a flexible tube with a metallic deflector attached to the distal end; it can be headed to the target area through the capsule operating channel. Performances of the colonoscopic capsule and intraoperative cleansing capabilities were successfully confirmed both in an in-vitro and ex-vivo experimental session. The innovative intraoperative cleansing system demonstrated promising results in terms of water injection, colonic wall cleansing procedure and subsequent water suction, thus guaranteeing to reduce the risk of inadequate visualization of the mucosa in endoscopic procedures.
Collapse
|
45
|
Iakovidis DK, Chatzis D, Chrysanthopoulos P, Koulaouzidis A. Blood detection in wireless capsule endoscope images based on salient superpixels. 2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC) 2015; 2015:731-4. [PMID: 26736366 DOI: 10.1109/embc.2015.7318466] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
46
|
Gu Y, Xie X, Li G, Sun T, Wang D, Yin Z, Zhang P, Wang Z. Design of Endoscopic Capsule With Multiple Cameras. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2015; 9:590-602. [PMID: 25376042 DOI: 10.1109/tbcas.2014.2359012] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
In order to reduce the miss rate of the wireless capsule endoscopy, in this paper, we propose a new system of the endoscopic capsule with multiple cameras. A master-slave architecture, including an efficient bus architecture and a four level clock management architecture, is applied for the Multiple Cameras Endoscopic Capsule (MCEC). For covering more area of the gastrointestinal tract wall with low power, multiple cameras with a smart image capture strategy, including movement sensitive control and camera selection, are used in the MCEC. To reduce the data transfer bandwidth and power consumption to prolong the MCEC's working life, a low complexity image compressor with PSNR 40.7 dB and compression rate 86% is implemented. A chipset is designed and implemented for the MCEC and a six cameras endoscopic capsule prototype is implemented by using the chipset. With the smart image capture strategy, the coverage rate of the MCEC prototype can achieve 98% and its power consumption is only about 7.1 mW.
Collapse
|
47
|
Ruan C, Guo X, Yang F. [Design of Adjustable Magnetic Field Generating Device in the Capsule Endoscope Tracking System]. SHENG WU YI XUE GONG CHENG XUE ZA ZHI = JOURNAL OF BIOMEDICAL ENGINEERING = SHENGWU YIXUE GONGCHENGXUE ZAZHI 2015; 32:900-904. [PMID: 26710466] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
The capsule endoscope swallowed from the mouth into the digestive system can capture the images of important gastrointestinal tract regions. It can compensate for the blind spot of traditional endoscopic techniques. It enables inspection of the digestive system without discomfort or need for sedation. However, currently available clinical capsule endoscope has some limitations such as the diagnostic information being not able to correspond to the orientation in the body, since the doctor is unable to control the capsule motion and orientation. To solve the problem, it is significant to track the position and orientation of the capsule in the human body. This study presents an AC excitation wireless tracking method in the capsule endoscope, and the sensor embedded in the capsule can measure the magnetic field generated by excitation coil. And then the position and orientation of the capsule can be obtained by solving a magnetic field inverse problem. Since the magnetic field decays with distance dramatically, the dynamic range of the received signal spans three orders of magnitude, we designed an adjustable alternating magnetic field generating device. The device can adjust the strength of the alternating magnetic field automatically through the feedback signal from the sensor. The prototype experiment showed that the adjustable magnetic field generating device was feasible. It could realize the automatic adjustment of the magnetic field strength successfully, and improve the tracking accuracy.
Collapse
|
48
|
Boal Carvalho P, Rosa B, Dias de Castro F, Moreira MJ, Cotter J. PillCam COLON 2 © in Crohn’s disease: A new concept of pan-enteric mucosal healing assessment. World J Gastroenterol 2015; 21:7233-7241. [PMID: 26109810 PMCID: PMC4476885 DOI: 10.3748/wjg.v21.i23.7233] [Citation(s) in RCA: 48] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/11/2015] [Revised: 02/27/2015] [Accepted: 04/17/2015] [Indexed: 02/06/2023] Open
Abstract
AIM: To evaluate mucosal healing in patients with small bowel plus colonic Crohn’s disease (CD) with a single non-invasive examination, by using PillCam COLON 2© (PCC2).
METHODS: Patients with non-stricturing nonpenetrating small bowel plus colonic CD in sustained corticosteroid-free remission were included. At diagnosis, patients had undergone ileocolonoscopy to identify active CD lesions, such as ulcers and erosions, and small bowel capsule endoscopy to assess the Lewis Score (LS). After ≥ 1 year of follow-up, patients underwent entire gastrointestinal tract evaluation with PCC2. The primary endpoint was assessment of CD mucosal healing, defined as no active colonic CD lesions and LS < 135.
RESULTS: Twelve patients were included (7 male; mean age: 32 years), and mean follow-up was 38 mo. The majority of patients (83.3%) received immunosuppressive therapy. Three patients (25%) achieved mucosal healing in both the small bowel and the colon, while disease activity was limited to either the small bowel or the colon in 5 patients (42%). It was possible to observe the entire gastrointestinal tract in 10 of the 12 patients (83%) who underwent PCC2.
CONCLUSION: Only three patients in sustained corticosteroid-free clinical remission achieved mucosal healing in both the small bowel and the colon, highlighting the limitations of clinical assessment when stratifying disease activity, and the need for pan-enteric endoscopy to guide therapeutic modification.
Collapse
|
49
|
Thekkek N, Lee MH, Polydorides AD, Rosen DG, Anandasabapathy S, Richards-Kortum R. Quantitative evaluation of in vivo vital-dye fluorescence endoscopic imaging for the detection of Barrett's-associated neoplasia. JOURNAL OF BIOMEDICAL OPTICS 2015; 20:56002. [PMID: 25950645 PMCID: PMC4423850 DOI: 10.1117/1.jbo.20.5.056002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/30/2014] [Accepted: 04/20/2015] [Indexed: 05/21/2023]
Abstract
Current imaging tools are associated with inconsistent sensitivity and specificity for detection of Barrett's-associated neoplasia. Optical imaging has shown promise in improving the classification of neoplasia in vivo. The goal of this pilot study was to evaluate whether in vivo vital dye fluorescence imaging (VFI) has the potential to improve the accuracy of early-detection of Barrett's-associated neoplasia. In vivo endoscopic VFI images were collected from 65 sites in 14 patients with confirmed Barrett's esophagus (BE), dysplasia, oresophageal adenocarcinoma using a modular video endoscope and a high-resolution microendoscope(HRME). Qualitative image features were compared to histology; VFI and HRME images show changes in glandular structure associated with neoplastic progression. Quantitative image features in VFI images were identified for objective image classification of metaplasia and neoplasia, and a diagnostic algorithm was developed using leave-one-out cross validation. Three image features extracted from VFI images were used to classify tissue as neoplastic or not with a sensitivity of 87.8% and a specificity of 77.6% (AUC = 0.878). A multimodal approach incorporating VFI and HRME imaging can delineate epithelial changes present in Barrett's-associated neoplasia. Quantitative analysis of VFI images may provide a means for objective interpretation of BE during surveillance.
Collapse
|
50
|
Lupaltsov VI, Yagnyuk AI. [THE WAYS FOR IMPROVEMENT OF PERITONITIS TREATMENT OUTCOMES AT A MODERN TIME]. KLINICHNA KHIRURHIIA 2015:32-36. [PMID: 26263640] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
The results of treatment of 53 patients, suffering extended peritonitis, were analyzed. Application of differentiated surgical tactics, the least traumatic volume of operative intervention for the patient, determination of indications for relaparotomy and secondary videolaparoscopic sanation, taking into account data on ultrasonic monitoring of abdominal organs, optimization of the inserted draining tubes quantity, depending on source and severity of peritonitis on background of early enteral feeding accomplished, have permitted to improve the patients treatment results, to reduce a postoperative complications and lethality rate.
Collapse
|