101
|
Baues C, Semrau R, Gaipl US, Bröckelmann PJ, Rosenbrock J, Engert A, Marnitz S. Checkpoint inhibitors and radiation treatment in Hodgkin's lymphoma : New study concepts of the German Hodgkin Study Group. Strahlenther Onkol 2016; 193:95-99. [PMID: 27704149 DOI: 10.1007/s00066-016-1050-4] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2016] [Accepted: 09/01/2016] [Indexed: 11/28/2022]
Abstract
BACKGROUND Patients with classical Hodgkin's lymphoma (cHL) have a good prognosis even in advanced stages. However, combined chemo- and radiotherapy, as the standard of care, is also associated with treatment-related toxicities such as organ damage, secondary neoplasias, infertility, or fatigue and long-term fatigue. Many patients suffer from this burden although their cHL was cured. Therefore, the efficacy of immune checkpoint inhibitors like anti-PD1/PD-L1 antibodies in the treatment of solid cancers and also in HL offers new options. A remarkable and durable response rate with a favorable toxicity profile was observed in heavily pretreated cHL patients. METHODS Planning to perform prospective randomized clinical trials in the content of radio-immune treatment in patients with Hodgkin's lymphoma (HL), we transferred the results of preliminary clinical studies and basic research in clinical relevant study concepts. RESULTS Based on these promising early phase trial data, the German Hodgkin Study Group (GHSG) will investigate innovative treatment regimens in upcoming phase II trials. CONCLUSION The therapeutic efficacy and potential synergies of anti-PD1 antibodies in combination with chemo- or radiotherapy will be investigated in various settings of HL.
Collapse
Affiliation(s)
- C Baues
- Medical Faculty, Department of Radiooncology, University of Cologne, Cologne, Germany. .,German Hodgkin Study Group (GHSG), University of Cologne, Cologne, Germany.
| | - R Semrau
- Medical Faculty, Department of Radiooncology, University of Cologne, Cologne, Germany.,German Hodgkin Study Group (GHSG), University of Cologne, Cologne, Germany
| | - U S Gaipl
- Department of Radiooncology, University hospital Erlangen, Erlangen, Germany
| | - P J Bröckelmann
- German Hodgkin Study Group (GHSG), University of Cologne, Cologne, Germany.,Medical Faculty, Department of Internal Medicine I, University of Cologne, Cologne, Germany
| | - J Rosenbrock
- Medical Faculty, Department of Radiooncology, University of Cologne, Cologne, Germany
| | - A Engert
- German Hodgkin Study Group (GHSG), University of Cologne, Cologne, Germany.,Medical Faculty, Department of Internal Medicine I, University of Cologne, Cologne, Germany
| | - S Marnitz
- Medical Faculty, Department of Radiooncology, University of Cologne, Cologne, Germany.,German Hodgkin Study Group (GHSG), University of Cologne, Cologne, Germany
| |
Collapse
|
102
|
Kriz J, Baues C, Engenhart-Cabillic R, Haverkamp U, Herfarth K, Lukas P, Schmidberger H, Marnitz-Schulze S, Fuchs M, Engert A, Eich HT. New quality assurance program integrating "modern radiotherapy" within the German Hodgkin Study Group. Strahlenther Onkol 2016; 193:100-108. [PMID: 27678010 DOI: 10.1007/s00066-016-1048-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2016] [Accepted: 08/29/2016] [Indexed: 10/20/2022]
Abstract
INTRODUCTION Field design changed substantially from extended-field RT (EF-RT) to involved-field RT (IF-RT) and now to involved-node RT (IN-RT) and involved-site RT (IS-RT) as well as treatment techniques in radiotherapy (RT) of Hodgkin's lymphoma (HL). The purpose of this article is to demonstrate the establishment of a quality assurance program (QAP) including modern RT techniques and field designs within the German Hodgkin Study Group (GHSG). METHODS In the era of modern conformal RT, this QAP had to be fundamentally adapted and a new evaluation process has been intensively discussed by the radiotherapeutic expert panel of the GHSG. RESULTS The expert panel developed guidelines and criteria to analyse "modern" field designs and treatment techniques. This work is based on a dataset of 11 patients treated within the sixth study generation (HD16-17). CONCLUSION To develop a QAP of "modern RT", the expert panel defined criteria for analysing current RT procedures. The consensus of a modified QAP in ongoing and future trials is presented. With this schedule, the QAP of the GHSG could serve as a model for other study groups.
Collapse
Affiliation(s)
- J Kriz
- Department of Radiation Oncology, University of Muenster, Albert-Schweitzer Campus 1, Gebäude 1 A, 48419, Muenster, Germany
| | - C Baues
- Department of Radiation Oncology, University of Cologne, Köln, Deutschland
| | | | - U Haverkamp
- Department of Radiation Oncology, University of Muenster, Albert-Schweitzer Campus 1, Gebäude 1 A, 48419, Muenster, Germany
| | - K Herfarth
- Department of Radiation Oncology, University of Heidelberg, Heidelberg, Deutschland
| | - P Lukas
- Department of Radiation Oncology, University of Innsbruck, Innsbruck, Deutschland
| | - H Schmidberger
- Department of Radiation Oncology, University of Mainz, Mainz, Deutschland
| | - S Marnitz-Schulze
- Department of Radiation Oncology, University of Cologne, Köln, Deutschland
| | - M Fuchs
- Department of Internal Medicine, University of Cologne, Köln, Deutschland
| | - A Engert
- Department of Internal Medicine, University of Cologne, Köln, Deutschland
| | - H T Eich
- Department of Radiation Oncology, University of Muenster, Albert-Schweitzer Campus 1, Gebäude 1 A, 48419, Muenster, Germany.
| |
Collapse
|
103
|
Schönecker S, Heinz C, Söhn M, Haimerl W, Corradini S, Pazos M, Belka C, Scheithauer H. Reduction of cardiac and coronary artery doses in irradiation of left-sided breast cancer during inspiration breath hold : A planning study. Strahlenther Onkol 2016; 192:750-758. [PMID: 27632341 DOI: 10.1007/s00066-016-1039-z] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2016] [Accepted: 08/12/2016] [Indexed: 12/21/2022]
Abstract
BACKGROUND AND PURPOSE The radiation dose received by the heart during adjuvant left-sided breast irradiation plays a crucial role in development of late toxicity. Although the absolute risk of cardiotoxicity can be reduced with modern irradiation techniques, cardiotoxic chemotherapy increases the risk of late damage. Thus, the radiation dose to the heart should be minimized. This study evaluated the influence of different amplitudes of inspiration breath hold (IBH) during simulated left-sided breast irradiation on cardiac doses compared to free breathing (FB). PATIENTS AND METHODS CT data of 11 lung cancer patients were retrospectively used as left-sided pseudo-breast cancer cases. Two CT scans were used, one during IBH and one during FB, and two treatment plans were generated. Relevant heart, lung, and left anterior descending artery (LAD) parameters were derived from dose-volume histograms. The normal tissue complication probabilities (NTCPs) for the heart were calculated based on the relative seriality model. Inspiration depth was quantified using chest volume and diameter, and correlated thereafter to a possible sparing of heart tissue. RESULTS Mean reduction of heart dose for IBH compared to FB was 40 % (1.65 vs. 0.99 Gy; p = 0.007). Maximum dose to the heart and LAD could be decreased by 33 % (p = 0.011) and 43 % (p = 0.024), respectively. The mean anteroposterior shift was 5 mm (range 0.9-9.5 mm). Significant negative correlations between the relative change in LAD mean dose and the mean thoracic diameter and volume change, as well as with the absolute change in thoracic diameter were seen. The NTCP for cardiac mortality could be decreased by about 78 % (p = 0.017). CONCLUSION For left-sided breast cancer patients, cardiac doses can be significantly decreased with tangential irradiation and IBH.
Collapse
Affiliation(s)
- S Schönecker
- Department of Radiation Oncology, University Hospital of Ludwig-Maximilian-University, Ziemssenstr. 1, 80336, Munich, Germany
| | - C Heinz
- Department of Radiation Oncology, University Hospital of Ludwig-Maximilian-University, Ziemssenstr. 1, 80336, Munich, Germany
| | - M Söhn
- Department of Radiation Oncology, University Hospital of Ludwig-Maximilian-University, Ziemssenstr. 1, 80336, Munich, Germany
| | - W Haimerl
- Department of Radiation Oncology, University Hospital of Ludwig-Maximilian-University, Ziemssenstr. 1, 80336, Munich, Germany
| | - S Corradini
- Department of Radiation Oncology, University Hospital of Ludwig-Maximilian-University, Ziemssenstr. 1, 80336, Munich, Germany
| | - M Pazos
- Department of Radiation Oncology, University Hospital of Ludwig-Maximilian-University, Ziemssenstr. 1, 80336, Munich, Germany
| | - C Belka
- Department of Radiation Oncology, University Hospital of Ludwig-Maximilian-University, Ziemssenstr. 1, 80336, Munich, Germany
| | - H Scheithauer
- Department of Radiation Oncology, University Hospital of Ludwig-Maximilian-University, Ziemssenstr. 1, 80336, Munich, Germany.
| |
Collapse
|
104
|
McQuaid D, Dunlop A, Nill S, Franzese C, Nutting CM, Harrington KJ, Newbold KL, Bhide SA. Evaluation of radiotherapy techniques for radical treatment of lateralised oropharyngeal cancers : Dosimetry and NTCP. Strahlenther Onkol 2016; 192:516-25. [PMID: 27295511 DOI: 10.1007/s00066-016-0980-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2015] [Accepted: 04/12/2016] [Indexed: 12/22/2022]
Abstract
AIM The aim of this study was to investigate potential advantages and disadvantages of three-dimensional conformal radiotherapy (3DCRT), multiple fixed-field intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) in terms of dose to the planning target volume (PTV), organs at risk (OARs) and normal tissue complication probability (NTCP) for delivering ipsilateral radiotherapy. MATERIALS AND METHODS 3DCRT, IMRT and VMAT were compared in patients with well-lateralised primary tonsillar cancers who underwent primary radical ipsilateral radiotherapy. The following parameters were compared: conformity index (CI); homogeneity index (HI); dose-volume histograms (DVHs) of PTVs and OARs; NTCP, risk of radiation-induced cancer and dose accumulation during treatment. RESULTS IMRT and VMAT were superior to 3DCRT in terms of CI, HI and dose to the target volumes, as well as mandible and dose accumulation robustness. The techniques were equivalent in terms of dose and NTCP for the contralateral oral cavity, contralateral submandibular gland and mandible, when specific dose constraint objectives were used on the oral cavity volume. Although the volume of normal tissue exposed to low-dose radiation was significantly higher with IMRT and VMAT, the risk of radiation-induced secondary malignancy was dependant on the mathematical model used. CONCLUSION This study demonstrates the superiority of IMRT/VMAT techniques over 3DCRT in terms of dose homogeneity, conformity and consistent dose delivery to the PTV throughout the course of treatment in patients with lateralised oropharyngeal cancers. Dosimetry and NTCP calculations show that these techniques are equivalent to 3DCRT with regard to the risk of acute mucositis when specific dose constraint objectives were used on the contralateral oral cavity OAR.
Collapse
Affiliation(s)
- D McQuaid
- Head and Neck Unit, Royal Marsden Hospital, Downs road, SM2 5PT, Sutton, Surrey, UK
- Head and Neck Unit, Royal Marsden Hospital, SW3 6JJ, London, UK
- The Institute of Cancer Research, SW3 6JB, London, UK
- The Institute of Cancer Research, SM2 5NG, Sutton, UK
| | - A Dunlop
- Head and Neck Unit, Royal Marsden Hospital, Downs road, SM2 5PT, Sutton, Surrey, UK
- Head and Neck Unit, Royal Marsden Hospital, SW3 6JJ, London, UK
- The Institute of Cancer Research, SW3 6JB, London, UK
- The Institute of Cancer Research, SM2 5NG, Sutton, UK
| | - S Nill
- Head and Neck Unit, Royal Marsden Hospital, Downs road, SM2 5PT, Sutton, Surrey, UK
- Head and Neck Unit, Royal Marsden Hospital, SW3 6JJ, London, UK
- The Institute of Cancer Research, SW3 6JB, London, UK
- The Institute of Cancer Research, SM2 5NG, Sutton, UK
| | - C Franzese
- Head and Neck Unit, Royal Marsden Hospital, Downs road, SM2 5PT, Sutton, Surrey, UK
- Head and Neck Unit, Royal Marsden Hospital, SW3 6JJ, London, UK
| | - C M Nutting
- Head and Neck Unit, Royal Marsden Hospital, Downs road, SM2 5PT, Sutton, Surrey, UK
- Head and Neck Unit, Royal Marsden Hospital, SW3 6JJ, London, UK
- The Institute of Cancer Research, SW3 6JB, London, UK
- The Institute of Cancer Research, SM2 5NG, Sutton, UK
| | - K J Harrington
- Head and Neck Unit, Royal Marsden Hospital, Downs road, SM2 5PT, Sutton, Surrey, UK
- Head and Neck Unit, Royal Marsden Hospital, SW3 6JJ, London, UK
- The Institute of Cancer Research, SW3 6JB, London, UK
- The Institute of Cancer Research, SM2 5NG, Sutton, UK
| | - K L Newbold
- Head and Neck Unit, Royal Marsden Hospital, Downs road, SM2 5PT, Sutton, Surrey, UK
- Head and Neck Unit, Royal Marsden Hospital, SW3 6JJ, London, UK
- The Institute of Cancer Research, SW3 6JB, London, UK
- The Institute of Cancer Research, SM2 5NG, Sutton, UK
| | - S A Bhide
- Head and Neck Unit, Royal Marsden Hospital, Downs road, SM2 5PT, Sutton, Surrey, UK.
- Head and Neck Unit, Royal Marsden Hospital, SW3 6JJ, London, UK.
- The Institute of Cancer Research, SW3 6JB, London, UK.
- The Institute of Cancer Research, SM2 5NG, Sutton, UK.
| |
Collapse
|
105
|
Münch S, Aichmeier S, Hapfelmeier A, Duma MN, Oechsner M, Feith M, Combs SE, Habermehl D. Comparison of dosimetric parameters and toxicity in esophageal cancer patients undergoing 3D conformal radiotherapy or VMAT. Strahlenther Onkol 2016; 192:722-9. [PMID: 27418129 DOI: 10.1007/s00066-016-1020-x] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2015] [Accepted: 06/24/2016] [Indexed: 12/25/2022]
Abstract
PURPOSE Volumetric-modulated arc therapy (VMAT) achieves high conformity to the planned target volume (PTV) and good sparing of organs at risk (OAR). This study compares dosimetric parameters and toxicity in esophageal cancer (EC) patients treated with VMAT and 3D conformal radiotherapy (3D-CRT). MATERIALS AND METHODS Between 2007 and 2014, 17 SC patients received neoadjuvant chemoradiation (CRT) with VMAT. Dose-volume histograms and toxicity were compared between these patients and 20 treated with 3D-CRT. All patients were irradiated with a total dose of 45 Gy. All VMAT patients received simultaneous chemotherapy with cisplatin and 5‑fluorouracil (5-FU) in treatment weeks 1 and 5. Of 20 patients treated with 3D-CRT, 13 (65 %) also received CRT with cisplatin and 5‑FU, whereas 6 patients (30 %) received CRT with weekly oxaliplatin and cetuximab, and a continuous infusion of 5‑FU (OE-7). RESULTS There were no differences in baseline characteristics between the treatment groups. For the lungs, VMAT was associated with a higher V5 (median 90.1 % vs. 79.7 %; p = 0.013) and V10 (68.2 % vs. 56.6 %; p = 0.014), but with a lower V30 (median 6.6 % vs. 11.0 %; p = 0.030). Regarding heart parameters, VMAT was associated with a higher V5 (median 100.0 % vs. 91.0 %; p = 0.043), V10 (92.0 % vs. 79.2 %; p = 0.047), and Dmax (47.5 Gy vs. 46.3 Gy; p = 0.003), but with a lower median dose (18.7 Gy vs. 30.0 Gy; p = 0.026) and V30 (17.7 % vs. 50.4 %; p = 0.015). Complete resection was achieved in 16 VMAT and 19 3D-CRT patients. Due to systemic progression, 2 patients did not undergo surgery. The most frequent postoperative complication was anastomosis insufficiency, occurring in 1 VMAT (6.7 %) and 5 3D-CRT patients (27.8 %; p = 0.180). Postoperative pneumonia was seen in 2 patients of each group (p = 1.000). There was no significant difference in 3‑year overall (65 % VMAT vs. 45 % 3D-CRT; p = 0.493) or 3‑year progression-free survival (53 % VMAT vs. 35 % 3D-CRT; p = 0.453). CONCLUSION Although dosimetric differences in lung and heart exposure were observed, no clinically relevant impact was detected in either patient group. In a real-life patient cohort, VMAT enables reduction of lung and heart V30 compared to 3D-CRT, which may contribute to reduced toxicity.
Collapse
|
106
|
Harrabi SB, Bougatf N, Mohr A, Haberer T, Herfarth K, Combs SE, Debus J, Adeberg S. Dosimetric advantages of proton therapy over conventional radiotherapy with photons in young patients and adults with low-grade glioma. Strahlenther Onkol 2016; 192:759-769. [PMID: 27363701 PMCID: PMC5080304 DOI: 10.1007/s00066-016-1005-9] [Citation(s) in RCA: 78] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2016] [Accepted: 05/20/2016] [Indexed: 12/26/2022]
Abstract
Background and purpose Low-grade glioma (LGG) is a very common brain tumor in pediatric patients typically associated with a very good prognosis. This prognosis makes it imperative that the risk of long-term treatment-related side effects be kept at an absolute minimum. Proton therapy (PRT) provides a radiation technique that has the potential to further reduce the genesis of radiogenic impairment. Materials and methods We retrospectively assessed 74 patients with LGG who underwent PRT. Conventional three-dimensional photon and PRT plans were generated after contouring structures of neurogenesis, crucial neuronal structures, and areas susceptible to secondary malignancies. Target volume coverage was evaluated using the homogeneity index (HI) and inhomogeneity coefficient (IC). Results were compared using the Wilcoxon-signed rank test, with p < 0.05 being statistically significant. Results Target volume coverage was comparable for the photon and proton plans. Overall, we could show an essential reduction in maximal, mean, and integral doses in critical neurologic structures, areas of neurogenesis, and structures of neurocognitive function. The study indicated specifically how contralaterally located structures could be spared with PRT. Conclusion PRT is a highly conformal radiation technique offering superior dosimetric advantages over conventional radiotherapy by allowing significant dose reduction for organs at risk (OAR) that are essential for neurologic function, neurocognition, and quality of life, thus demonstrating the potential of this technique for minimizing long-term sequelae.
Collapse
Affiliation(s)
- S B Harrabi
- Heidelberg Institute of Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.,Heidelberg Ion-Beam Therapy Center (HIT), Im Neuenheimer Feld 450, 69120, Heidelberg, Germany.,Dept. of Radiation Oncology, University Hospital Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - N Bougatf
- Heidelberg Institute of Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.,Dept. of Radiation Oncology, University Hospital Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.,Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120, Heidelberg, Germany
| | - A Mohr
- Heidelberg Institute of Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.,Dept. of Radiation Oncology, University Hospital Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - T Haberer
- Heidelberg Institute of Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.,Heidelberg Ion-Beam Therapy Center (HIT), Im Neuenheimer Feld 450, 69120, Heidelberg, Germany
| | - K Herfarth
- Heidelberg Institute of Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.,Heidelberg Ion-Beam Therapy Center (HIT), Im Neuenheimer Feld 450, 69120, Heidelberg, Germany.,Dept. of Radiation Oncology, University Hospital Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - S E Combs
- Department of Radiation Sciences (DRS), Institute of Innovative Radiotherapy (iRT), Helmholtz Zentrum München, Ingolstädter Landstraße 1, 85764, Oberschleißheim, Germany.,Partner Site Munich, Deutsches Konsortium für Translationale Krebsforschung (dktk), Munich, Germany
| | - J Debus
- Heidelberg Institute of Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.,Heidelberg Ion-Beam Therapy Center (HIT), Im Neuenheimer Feld 450, 69120, Heidelberg, Germany.,Dept. of Radiation Oncology, University Hospital Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.,Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120, Heidelberg, Germany
| | - S Adeberg
- Heidelberg Institute of Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120, Heidelberg, Germany. .,Heidelberg Ion-Beam Therapy Center (HIT), Im Neuenheimer Feld 450, 69120, Heidelberg, Germany. .,Dept. of Radiation Oncology, University Hospital Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany. .,Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120, Heidelberg, Germany.
| |
Collapse
|
107
|
Adeberg S, Harrabi SB, Bougatf N, Bernhardt D, Rieber J, Koerber SA, Syed M, Sprave T, Mohr A, Abdollahi A, Haberer T, Combs SE, Herfarth K, Debus J, Rieken S. Intensity-modulated proton therapy, volumetric-modulated arc therapy, and 3D conformal radiotherapy in anaplastic astrocytoma and glioblastoma : A dosimetric comparison. Strahlenther Onkol 2016; 192:770-9. [PMID: 27334276 DOI: 10.1007/s00066-016-1007-7] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2016] [Accepted: 05/20/2016] [Indexed: 01/18/2023]
Abstract
PURPOSE The prognosis for high-grade glioma (HGG) patients is poor; thus, treatment-related side effects need to be minimized to conserve quality of life and functionality. Advanced techniques such as proton radiation therapy (PRT) and volumetric-modulated arc therapy (VMAT) may potentially further reduce the frequency and severity of radiogenic impairment. MATERIALS AND METHODS We retrospectively assessed 12 HGG patients who had undergone postoperative intensity-modulated proton therapy (IMPT). VMAT and 3D conformal radiotherapy (3D-CRT) plans were generated and optimized for comparison after contouring crucial neuronal structures important for neurogenesis and neurocognitive function. Integral dose (ID), homogeneity index (HI), and inhomogeneity coefficient (IC) were calculated from dose statistics. Toxicity data were evaluated. RESULTS Target volume coverage was comparable for all three modalities. Compared to 3D-CRT and VMAT, PRT showed statistically significant reductions (p < 0.05) in mean dose to whole brain (-20.2 %, -22.7 %); supratentorial (-14.2 %, -20,8 %) and infratentorial (-91.0 %, -77.0 %) regions; brainstem (-67.6 %, -28.1 %); pituitary gland (-52.9 %, -52.5 %); contralateral hippocampus (-98.9 %, -98.7 %); and contralateral subventricular zone (-62.7 %, -66.7 %, respectively). Fatigue (91.7 %), radiation dermatitis (75.0 %), focal alopecia (100.0 %), nausea (41.7 %), cephalgia (58.3 %), and transient cerebral edema (16.7 %) were the most common acute toxicities. CONCLUSION Essential dose reduction while maintaining equal target volume coverage was observed using PRT, particularly in contralaterally located critical neuronal structures, areas of neurogenesis, and structures of neurocognitive functions. These findings were supported by preliminary clinical results confirming the safety and feasibility of PRT in HGG.
Collapse
|
108
|
Horn S, Fournier-Bidoz N, Pernin V, Peurien D, Vaillant M, Dendale R, Fourquet A, Kirova YM. Comparison of passive-beam proton therapy, helical tomotherapy and 3D conformal radiation therapy in Hodgkin's lymphoma female patients receiving involved-field or involved site radiation therapy. Cancer Radiother 2016; 20:98-103. [PMID: 26992750 DOI: 10.1016/j.canrad.2015.11.002] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2015] [Revised: 09/23/2015] [Accepted: 11/09/2015] [Indexed: 01/10/2023]
Abstract
PURPOSE Second cancers and cardiovascular toxicities are long term radiation toxicity in locally advanced Hodgkin's lymphomas. In this study, we evaluate the potential reduction of dose to normal tissue with helical tomotherapy and proton therapy for Hodgkin's lymphoma involved-field or involved-site irradiation compared to standard 3D conformal radiation therapy. PATIENTS AND METHODS Fourteen female patients with supradiaphragmatic Hodgkin's lymphoma were treated at our institution with 3D conformal radiation therapy or helical tomotherapy to a dose of 30Gy in 15 fractions. A planning comparison was achieved including proton therapy with anterior/posterior passive scattered beams weighted 20Gy/10Gy. RESULTS Mean doses to breasts, lung tissue and heart with proton therapy were significantly lower compared to helical tomotherapy and to 3D conformal radiation therapy. Helical tomotherapy assured the best protection of lungs from doses above 15Gy with the V20Gy equal to 16.4%, compared to 19.7% for proton therapy (P=0.01) or 22.4% with 3D conformal radiation therapy (P<0.01). Volumes of lung receiving doses below 15Gy were significantly larger for helical tomotherapy than for proton therapy or 3D conformal radiation therapy, with respective lung doses V10Gy=37.2%, 24.6% and 27.4%. Also, in the domain of low doses, the volumes of breast that received more than 10Gy or more than 4Gy with helical tomotherapy were double the corresponding volumes for proton therapy, with V4Gy representing more than a third of one breast volume with helical tomotherapy. CONCLUSIONS Helical tomotherapy achieved a better protection to the lungs for doses above 15Gy than passive proton therapy or 3D conformal radiation therapy. However, dose distributions could generally be improved by using protons even with our current passive-beam technology, especially allowing less low dose spreading and better breast tissue sparing, which is an important factor to consider when treating Hodgkin's lymphomas in female patients. Prospective clinical study is needed to evaluate the tolerance and confirm these findings.
Collapse
Affiliation(s)
- S Horn
- Department of Radiation Oncology, institut Curie, 26, rue d'Ulm, 75005 Paris, France
| | - N Fournier-Bidoz
- Department of Radiation Oncology, institut Curie, 26, rue d'Ulm, 75005 Paris, France
| | - V Pernin
- Department of Radiation Oncology, institut Curie, 26, rue d'Ulm, 75005 Paris, France
| | - D Peurien
- Department of Radiation Oncology, institut Curie, 26, rue d'Ulm, 75005 Paris, France
| | - M Vaillant
- Department of Radiation Oncology, institut Curie, 26, rue d'Ulm, 75005 Paris, France
| | - R Dendale
- Department of Radiation Oncology, institut Curie, 26, rue d'Ulm, 75005 Paris, France
| | - A Fourquet
- Department of Radiation Oncology, institut Curie, 26, rue d'Ulm, 75005 Paris, France
| | - Y M Kirova
- Department of Radiation Oncology, institut Curie, 26, rue d'Ulm, 75005 Paris, France.
| |
Collapse
|
109
|
Combs SE, Nüsslin F, Wilkens JJ. Individualized radiotherapy by combining high-end irradiation and magnetic resonance imaging. Strahlenther Onkol 2016; 192:209-15. [PMID: 26852244 DOI: 10.1007/s00066-016-0944-5] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2015] [Accepted: 01/14/2016] [Indexed: 01/22/2023]
Abstract
Image-guided radiotherapy (IGRT) has been integrated into daily clinical routine and can today be considered the standard especially with high-dose radiotherapy. Currently imaging is based on MV- or kV-CT, which has clear limitations especially in soft-tissue contrast. Thus, combination of magnetic resonance (MR) imaging and high-end radiotherapy opens a new horizon. The intricate technical properties of MR imagers pose a challenge to technology when combined with radiation technology. Several solutions that are almost ready for routine clinical application have been developed. The clinical questions include dose-escalation strategies, monitoring of changes during treatment as well as imaging without additional radiation exposure during treatment.
Collapse
Affiliation(s)
- Stephanie E Combs
- Department of Radiation Oncology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Straße 22, 81675, München, Germany. .,Institute of Innovative Radiotherapy (iRT), Department of Radiation Sciences (DRS), Helmholtz Zentrum München, Ingolstädter Landstraße 1, 85764, Neuherberg, Germany.
| | - Fridtjof Nüsslin
- Department of Radiation Oncology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Straße 22, 81675, München, Germany
| | - Jan J Wilkens
- Department of Radiation Oncology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Straße 22, 81675, München, Germany.,Institute of Innovative Radiotherapy (iRT), Department of Radiation Sciences (DRS), Helmholtz Zentrum München, Ingolstädter Landstraße 1, 85764, Neuherberg, Germany
| |
Collapse
|
110
|
Stromberger C, Cozzi L, Budach V, Fogliata A, Ghadjar P, Wlodarczyk W, Jamil B, Raguse JD, Böttcher A, Marnitz S. Unilateral and bilateral neck SIB for head and neck cancer patients : Intensity-modulated proton therapy, tomotherapy, and RapidArc. Strahlenther Onkol 2016; 192:232-9. [PMID: 26852243 DOI: 10.1007/s00066-016-0945-4] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2015] [Accepted: 01/14/2016] [Indexed: 12/22/2022]
Abstract
AIM To compare simultaneous integrated boost plans for intensity-modulated proton therapy (IMPT), helical tomotherapy (HT), and RapidArc therapy (RA) for patients with head and neck cancer. PATIENTS AND METHODS A total of 20 patients with squamous cell carcinoma of the head and neck received definitive chemoradiation with bilateral (n = 14) or unilateral (n = 6) neck irradiation and were planned using IMPT, HT, and RA with 54.4, 60.8, and 70.4 GyE/Gy in 32 fractions. Dose distributions, coverage, conformity, homogeneity to planning target volumes (PTV)s and sparing of organs at risk and normal tissue were compared. RESULTS All unilateral and bilateral plans showed excellent PTV coverage and acceptable dose conformity. For unilateral treatment, IMPT delivered substantially lower mean doses to contralateral salivary glands (< 0.001-1.1 Gy) than both rotational techniques did (parotid gland: 6-10 Gy; submandibular gland: 15-20 Gy). Regarding the sparing of classical organs at risk for bilateral treatment, IMPT and HT were similarly excellent and RA was satisfactory. CONCLUSION For unilateral neck irradiation, IMPT may minimize the dry mouth risk in this subgroup but showed no advantage over HT for bilateral neck treatment regarding classical organ-at-risk sparing. All methods satisfied modern standards regarding toxicity and excellent target coverage for unilateral and bilateral treatment of head and neck cancer at the planning level.
Collapse
|
111
|
Signorelli L, Patcas R, Peltomäki T, Schätzle M. Radiation dose of cone-beam computed tomography compared to conventional radiographs in orthodontics. J Orofac Orthop 2016; 77:9-15. [PMID: 26747662 DOI: 10.1007/s00056-015-0002-4] [Citation(s) in RCA: 57] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2012] [Accepted: 07/05/2014] [Indexed: 02/04/2023]
Abstract
OBJECTIVES The aim of this study was to determine radiation doses of different cone-beam computed tomography (CBCT) scan modes in comparison to a conventional set of orthodontic radiographs (COR) by means of phantom dosimetry. MATERIALS AND METHODS Thermoluminescent dosimeter (TLD) chips (3 × 1 × 1 mm) were used on an adult male tissue-equivalent phantom to record the distribution of the absorbed radiation dose. Three different scanning modes (i.e., portrait, normal landscape, and fast scan landscape) were compared to CORs [i.e., conventional lateral (LC) and posteroanterior (PA) cephalograms and digital panoramic radiograph (OPG)]. RESULTS The following radiation levels were measured: 131.7, 91, and 77 μSv in the portrait, normal landscape, and fast landscape modes, respectively. The overall effective dose for a COR was 35.81 μSv (PA: 8.90 μSv; OPG: 21.87 μSv; LC: 5.03 μSv). DISCUSSION Although one CBCT scan may replace all CORs, one set of CORs still entails 2-4 times less radiation than one CBCT. Depending on the scan mode, the radiation dose of a CBCT is about 3-6 times an OPG, 8-14 times a PA, and 15-26 times a lateral LC. Finally, in order to fully reconstruct cephalograms including the cranial base and other important structures, the CBCT portrait mode must be chosen, rendering the difference in radiation exposure even clearer (131.7 vs. 35.81 μSv). Shielding radiation-sensitive organs can reduce the effective dose considerably. CONCLUSION CBCT should not be recommended for use in all orthodontic patients as a substitute for a conventional set of radiographs. In CBCT, reducing the height of the field of view and shielding the thyroid are advisable methods and must be implemented to lower the exposure dose.
Collapse
|
112
|
Abdul KSM, Jayasinghe SS, Chandana EPS, Jayasumana C, De Silva PMCS. Arsenic and human health effects: A review. Environ Toxicol Pharmacol 2015; 40:828-46. [PMID: 26476885 DOI: 10.1016/j.etap.2015.09.016] [Citation(s) in RCA: 410] [Impact Index Per Article: 45.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/16/2015] [Revised: 09/22/2015] [Accepted: 09/26/2015] [Indexed: 05/18/2023]
Abstract
Arsenic (As) is ubiquitous in nature and humans being exposed to arsenic via atmospheric air, ground water and food sources are certain. Major sources of arsenic contamination could be either through geological or via anthropogenic activities. In physiological individuals, organ system is described as group of organs that transact collectively and associate with other systems for conventional body functions. Arsenic has been associated with persuading a variety of complications in body organ systems: integumentary, nervous, respiratory, cardiovascular, hematopoietic, immune, endocrine, hepatic, renal, reproductive system and development. In this review, we outline the effects of arsenic on the human body with a main focus on assorted organ systems with respective disease conditions. Additionally, underlying mechanisms of disease development in each organ system due to arsenic have also been explored. Strikingly, arsenic has been able to induce epigenetic changes (in utero) and genetic mutations (a leading cause of cancer) in the body. Occurrence of various arsenic induced health effects involving emerging areas such as epigenetics and cancer along with their respective mechanisms are also briefly discussed.
Collapse
Affiliation(s)
| | | | | | - Channa Jayasumana
- Department of Pharmacology, Faculty of Medicine, Rajarata University, Anuradhapura 50008, Sri Lanka
| | - P Mangala C S De Silva
- Department of Zoology, Faculty of Science, University of Ruhuna, Matara 81000, Sri Lanka
| |
Collapse
|
113
|
Fleckenstein J, Kremp K, Kremp S, Palm J, Rübe C. IMRT and 3D conformal radiotherapy with or without elective nodal irradiation in locally advanced NSCLC: A direct comparison of PET-based treatment planning. Strahlenther Onkol 2016; 192:75-82. [PMID: 26438071 DOI: 10.1007/s00066-015-0900-9] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2015] [Accepted: 09/09/2015] [Indexed: 12/13/2022]
Abstract
AIM The potential of intensity-modulated radiation therapy (IMRT) as opposed to three-dimensional conformal radiotherapy (3D-CRT) is analyzed for two different concepts of fluorodeoxyglucose positron emission tomography (FDG PET)-based target volume delineation in locally advanced non-small cell lung cancer (LA-NSCLC): involved-field radiotherapy (IF-RT) vs. elective nodal irradiation (ENI). METHODS Treatment planning was performed for 41 patients with LA-NSCLC, using four different planning approaches (3D-CRT-IF, 3D-CRT-ENI, IMRT-IF, IMRT-ENI). ENI included a boost irradiation after 50 Gy. For each plan, maximum dose escalation was calculated based on prespecified normal tissue constraints. The maximum prescription dose (PD), tumor control probability (TCP), conformal indices (CI), and normal tissue complication probabilities (NTCP) were analyzed. RESULTS IMRT resulted in statistically significant higher prescription doses for both target volume concepts as compared with 3D-CRT (ENI: 68.4 vs. 60.9 Gy, p < 0.001; IF: 74.3 vs. 70.1 Gy, p < 0.03). With IMRT-IF, a PD of at least 66 Gy was achieved for 95 % of all plans. For IF as compared with ENI, there was a considerable theoretical increase in TCP (IMRT: 27.3 vs. 17.7 %, p < 0.00001; 3D-CRT: 20.2 vs. 9.9 %, p < 0.00001). The esophageal NTCP showed a particularly good sparing with IMRT vs. 3D-CRT (ENI: 12.3 vs. 30.9 % p < 0.0001; IF: 15.9 vs. 24.1 %; p < 0.001). CONCLUSION The IMRT technique and IF target volume delineation allow a significant dose escalation and an increase in TCP. IMRT results in an improved sparing of OARs as compared with 3D-CRT at equivalent dose levels.
Collapse
|
114
|
Farzin M, Molls M, Astner S, Rondak IC, Oechsner M. Simultaneous integrated vs. sequential boost in VMAT radiotherapy of high-grade gliomas. Strahlenther Onkol 2015; 191:945-52. [PMID: 26340939 DOI: 10.1007/s00066-015-0888-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2014] [Accepted: 08/07/2015] [Indexed: 11/29/2022]
Abstract
BACKGROUND In 20 patients with high-grade gliomas, we compared two methods of planning for volumetric-modulated arc therapy (VMAT): simultaneous integrated boost (SIB) vs. sequential boost (SEB). The investigation focused on the analysis of dose distributions in the target volumes and the organs at risk (OARs). METHOD After contouring the target volumes [planning target volumes (PTVs) and boost volumes (BVs)] and OARs, SIB planning and SEB planning were performed. The SEB method consisted of two plans: in the first plan the PTV received 50 Gy in 25 fractions with a 2-Gy dose per fraction. In the second plan the BV received 10 Gy in 5 fractions with a dose per fraction of 2 Gy. The doses of both plans were summed up to show the total doses delivered. In the SIB method the PTV received 54 Gy in 30 fractions with a dose per fraction of 1.8 Gy, while the BV received 60 Gy in the same fraction number but with a dose per fraction of 2 Gy. RESULTS All of the OARs showed higher doses (Dmax and Dmean) in the SEB method when compared with the SIB technique. The differences between the two methods were statistically significant in almost all of the OARs. Analysing the total doses of the target volumes we found dose distributions with similar homogeneities and comparable total doses. CONCLUSION Our analysis shows that the SIB method offers advantages over the SEB method in terms of sparing OARs.
Collapse
Affiliation(s)
- Mostafa Farzin
- Department of Radiation Oncology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Strasse 22, 81675, Munich, Germany. .,Brain and Spinal Cord Injury Research Center, Neuroscience Institute, Tehran University of Medical Science, Tehran, Iran.
| | - Michael Molls
- Department of Radiation Oncology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Strasse 22, 81675, Munich, Germany.
| | - Sabrina Astner
- Department of Radiation Oncology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Strasse 22, 81675, Munich, Germany.
| | - Ina-Christine Rondak
- Institut für Medizinische Statistik und Epidemiologie, Klinikum rechts der Isar, Technische Universität München, Munich, Germany.
| | - Markus Oechsner
- Department of Radiation Oncology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Strasse 22, 81675, Munich, Germany.
| |
Collapse
|
115
|
Lee DY, Park JW, Kim TH, Lee JH, Kim BH, Woo SM, Kim SS, Lee WJ, Kim DY, Kim CM. Prognostic indicators for radiotherapy of abdominal lymph node metastases from hepatocellular carcinoma. Strahlenther Onkol 2015; 191:835-44. [PMID: 26174506 DOI: 10.1007/s00066-015-0873-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2015] [Accepted: 06/23/2015] [Indexed: 02/06/2023]
Abstract
PURPOSE To identify prognostic indicators in patients treated with radiotherapy (RT) for metastases from hepatocellular carcinoma (HCC) in abdominal lymph nodes (LNs). PATIENTS AND METHODS RT was used to treat 65 patients for metastases from HCC in abdominal LNs. Total radiation dose was 30-60 Gy (median 52.8 Gy), with fraction size 1.8-3 Gy. RT was administered five times per week to an equivalent dose in 2-Gy fractions (EQD2; Gy10) of 32.5-65 Gy10 (median 54 Gy10) and an α/βratio for tumor and acute effects of normal tissue of 10. RESULTS Median overall survival (OS) in all patients was 8.1 months. LN responders had significantly higher median OS than nonresponders (14.5 vs. 3.7 months, p < 0.05). Multivariate analysis showed that Child-Pugh classification, status of intrahepatic tumor, number of metastatic LNs, and LN response were independently predictive of OS (p < 0.05 each). Based on results of multivariate analysis, patients were prognostically stratified according to pretreatment risk factors, including Child-Pugh classification, intrahepatic tumor status, and number of metastatic LNs; with the expected median OS in patients with ≥ 2, 1, and 0 risk factors being 2.9, 9.8, and 27.6 months, respectively (p < 0.05). CONCLUSION Our data showed that LN response to RT was an independent prognostic factor for OS in advanced HCC patients with abdominal LN metastases, and suggested that RT for metastatic LNs might improve OS in these patients. In addition, our data suggest that Child-Pugh classification, intrahepatic tumor status, and number of metastatic LNs may be useful prognostic and therapeutic indicators for selecting treatment strategies.
Collapse
Affiliation(s)
- Doo Yeul Lee
- Center for Liver Cancer, Research Institute and Hospital, National Cancer Center, 323 Ilsan-ro, Ilsandong-gu, Goyang-si, Gyeonggi-do, 410-769, Republic of Korea, Goyang, Korea
| | - Joong-Won Park
- Center for Liver Cancer, Research Institute and Hospital, National Cancer Center, 323 Ilsan-ro, Ilsandong-gu, Goyang-si, Gyeonggi-do, 410-769, Republic of Korea, Goyang, Korea
| | - Tae Hyun Kim
- Center for Liver Cancer, Research Institute and Hospital, National Cancer Center, 323 Ilsan-ro, Ilsandong-gu, Goyang-si, Gyeonggi-do, 410-769, Republic of Korea, Goyang, Korea.
| | - Ju Hee Lee
- Center for Liver Cancer, Research Institute and Hospital, National Cancer Center, 323 Ilsan-ro, Ilsandong-gu, Goyang-si, Gyeonggi-do, 410-769, Republic of Korea, Goyang, Korea
| | - Bo Hyun Kim
- Center for Liver Cancer, Research Institute and Hospital, National Cancer Center, 323 Ilsan-ro, Ilsandong-gu, Goyang-si, Gyeonggi-do, 410-769, Republic of Korea, Goyang, Korea
| | - Sang Myung Woo
- Center for Liver Cancer, Research Institute and Hospital, National Cancer Center, 323 Ilsan-ro, Ilsandong-gu, Goyang-si, Gyeonggi-do, 410-769, Republic of Korea, Goyang, Korea
| | - Sang Soo Kim
- Center for Liver Cancer, Research Institute and Hospital, National Cancer Center, 323 Ilsan-ro, Ilsandong-gu, Goyang-si, Gyeonggi-do, 410-769, Republic of Korea, Goyang, Korea
| | - Woo Jin Lee
- Center for Liver Cancer, Research Institute and Hospital, National Cancer Center, 323 Ilsan-ro, Ilsandong-gu, Goyang-si, Gyeonggi-do, 410-769, Republic of Korea, Goyang, Korea
| | - Dae Yong Kim
- Center for Liver Cancer, Research Institute and Hospital, National Cancer Center, 323 Ilsan-ro, Ilsandong-gu, Goyang-si, Gyeonggi-do, 410-769, Republic of Korea, Goyang, Korea
| | - Chang-Min Kim
- Center for Liver Cancer, Research Institute and Hospital, National Cancer Center, 323 Ilsan-ro, Ilsandong-gu, Goyang-si, Gyeonggi-do, 410-769, Republic of Korea, Goyang, Korea
| |
Collapse
|
116
|
Scoccianti S, Detti B, Gadda D, Greto D, Furfaro I, Meacci F, Simontacchi G, Di Brina L, Bonomo P, Giacomelli I, Meattini I, Mangoni M, Cappelli S, Cassani S, Talamonti C, Bordi L, Livi L. Organs at risk in the brain and their dose-constraints in adults and in children: a radiation oncologist's guide for delineation in everyday practice. Radiother Oncol 2015; 114:230-8. [PMID: 25701297 DOI: 10.1016/j.radonc.2015.01.016] [Citation(s) in RCA: 129] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2014] [Revised: 12/01/2014] [Accepted: 01/05/2015] [Indexed: 11/30/2022]
Abstract
PURPOSE Accurate organs at risk definition is essential for radiation treatment of brain tumors. The aim of this study is to provide a stepwise and simplified contouring guide to delineate the OARs in the brain as it would be done in the everyday practice of planning radiotherapy for brain cancer treatment. METHODS Anatomical descriptions and neuroimaging atlases of the brain were studied. The dosimetric constraints used in literature were reviewed. RESULTS A Computed Tomography and Magnetic Resonance Imaging based detailed atlas was developed jointly by radiation oncologists, a neuroradiologist and a neurosurgeon. For each organ brief anatomical notion, main radiological reference points and useful considerations are provided. Recommended dose-constraints both for adult and pediatric patients were also provided. CONCLUSIONS This report provides guidelines for OARs delineation and their dose-constraints for the treatment planning of patients with brain tumors.
Collapse
Affiliation(s)
- Silvia Scoccianti
- Radiation Oncology, Azienda Universitaria Ospedaliera Careggi, Florence, Italy.
| | - Beatrice Detti
- Radiation Oncology, Azienda Universitaria Ospedaliera Careggi, Florence, Italy
| | - Davide Gadda
- Neuroradiology Unit, Azienda Universitaria Ospedaliera Careggi, Florence, Italy
| | - Daniela Greto
- Radiation Oncology, Azienda Universitaria Ospedaliera Careggi, Florence, Italy
| | - Ilaria Furfaro
- Radiation Oncology, Azienda Universitaria Ospedaliera Careggi, Florence, Italy
| | - Fiammetta Meacci
- Radiation Oncology, Azienda Universitaria Ospedaliera Careggi, Florence, Italy
| | | | - Lucia Di Brina
- Radiation Oncology, Azienda Universitaria Ospedaliera Careggi, Florence, Italy
| | - Pierluigi Bonomo
- Radiation Oncology, Azienda Universitaria Ospedaliera Careggi, Florence, Italy
| | - Irene Giacomelli
- Radiation Oncology, Azienda Universitaria Ospedaliera Careggi, Florence, Italy
| | - Icro Meattini
- Radiation Oncology, Azienda Universitaria Ospedaliera Careggi, Florence, Italy
| | - Monica Mangoni
- Radiation Oncology, Azienda Universitaria Ospedaliera Careggi, Florence, Italy
| | - Sabrina Cappelli
- Radiation Oncology, Azienda Universitaria Ospedaliera Careggi, Florence, Italy
| | - Sara Cassani
- Radiation Oncology, Azienda Universitaria Ospedaliera Careggi, Florence, Italy
| | - Cinzia Talamonti
- Medical Physics, Azienda Universitaria Ospedaliera Careggi, Florence, Italy
| | - Lorenzo Bordi
- Neurosurgery, Azienda Universitaria Ospedaliera Careggi, Florence, Italy
| | - Lorenzo Livi
- Radiation Oncology, Azienda Universitaria Ospedaliera Careggi, Florence, Italy
| |
Collapse
|
117
|
Rehman JU, Tailor RC, Isa M, Afzal M, Chow J, Ibbott GS. Evaluations of secondary cancer risk in spine radiotherapy using 3DCRT, IMRT, and VMAT: A phantom study. Med Dosim 2014; 40:70-5. [PMID: 25434808 DOI: 10.1016/j.meddos.2014.10.003] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2014] [Revised: 10/18/2014] [Accepted: 10/21/2014] [Indexed: 11/16/2022]
Abstract
This study evaluated the secondary cancer risk from volumetric-modulated arc therapy (VMAT) for spine radiotherapy compared with intensity-modulated radiotherapy (IMRT) and 3-dimensional conformal radiotherapy (3DCRT). Computed tomography images of an Radiological Physics Center spine anthropomorphic phantom were exported to a treatment planning system (Pinnacle(3), version 9.4). Radiation treatment plans for spine were prepared using VMAT (dual-arc), 7-field IMRT (beam angles: 110°, 130°, 150°, 180°, 210°, 230°, and 250°), and 4-field 3DCRT technique. The mean and maximum doses, dose-volume histograms, and volumes receiving more than 2 and 4Gy to organs at risk (OARs) were calculated and compared. The lifetime risk for secondary cancers was estimated according to the National Cancer Registry Programme Report 116. VMAT delivered the lowest maximum dose to the esophagus (4.03Gy), bone (8.11Gy), heart (2.11Gy), spinal cord (6.45Gy), and whole lung (5.66Gy) as compared with other techniques (IMRT and 3DCRT). The volumes of OAR (esophagus) receiving more than 4Gy were 0% for VMAT, 27.06% for IMRT, and up to 32.35% for 3DCRT. The estimated risk for secondary cancer in the respective OAR is considerably lower in VMAT compared with other techniques. The results of maximum doses and volumes of OARs suggest that the risk of secondary cancer induction for the spine in VMAT is lower than IMRT and 3DCRT, whereas VMAT has the best target coverage compared with the other techniques.
Collapse
Affiliation(s)
- Jalil ur Rehman
- Department of Physics, The Islamia University of Bahawalpur, Bahawalpur, Pakistan; Department of Radiation Physics, UT MD Anderson Cancer Center, Houston, TX.
| | - Ramesh C Tailor
- Department of Radiation Physics, UT MD Anderson Cancer Center, Houston, TX
| | - Muhammad Isa
- Department of Physics, The Islamia University of Bahawalpur, Bahawalpur, Pakistan; Princess Margaret Cancer Center, University Health Network, Toronto, Ontario, Canada
| | - Muhammad Afzal
- Department of Physics, The Islamia University of Bahawalpur, Bahawalpur, Pakistan
| | - James Chow
- Princess Margaret Cancer Center, University Health Network, Toronto, Ontario, Canada
| | - Geoffrey S Ibbott
- Department of Radiation Physics, UT MD Anderson Cancer Center, Houston, TX
| |
Collapse
|
118
|
Simha V, Patel FD, Sharma SC, Rai B, Oinam AS, krishnatry R, Dhanireddy B. Evaluation of intrafraction motion of the organs at risk in image-based brachytherapy of cervical cancer. Brachytherapy 2014; 13:562-7. [PMID: 25030951 DOI: 10.1016/j.brachy.2014.05.016] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2014] [Revised: 05/01/2014] [Accepted: 05/12/2014] [Indexed: 11/29/2022]
Abstract
PURPOSE/INTRODUCTION To assess the variation in the doses received by the organs at risk (OARs) that can occur during treatment planning of cervical cancer by image-based brachytherapy. METHODS AND MATERIALS After intracavitary application, two sets of images-CT and MRI-were obtained. The two sets of images were fused together with respect to the applicator. Contouring was done separately on CT and MR images. Dose received by the OARs on CT images with respect to the plans made on the MR images was estimated and compared with those on the MR images. RESULTS Although there was always a difference between the dose received by the OARs based on the CT and MRI contours, it was not significant for the bladder and rectum; 2 cc doses differed by 0.49 Gy (±0.44) p = 0.28 for the bladder and 0.30 Gy (±0.29) p = 0.16 for the rectum. The 1 cc and 0.1 cc differences were also not significant. However for the sigmoid colon, there was significant intrafraction variation in the 2 cc doses 0.61 (±0.6) p = 0.001, 1 cc doses 0.73 (±0.67) Gy p = 0.00, and 0.1 cc dose 0.97 (±0.93) Gy p = 0.009. CONCLUSIONS The variation in the doses to the OARs must be considered while weighing target coverage against overdose to the OARs. Although not significant for the bladder and rectum, it was significant for the sigmoid colon. Estimated doses to OARs on the planning system may not be the same dose delivered at the time of treatment.
Collapse
Affiliation(s)
- Vijai Simha
- Department of Radiotherapy and Oncology, Post Graduate Institute of Medical Education and Research (PGIMER), Chandigarh, India.
| | - Firuza Darius Patel
- Department of Radiotherapy and Oncology, Post Graduate Institute of Medical Education and Research (PGIMER), Chandigarh, India
| | - Suresh Chander Sharma
- Department of Radiotherapy and Oncology, Post Graduate Institute of Medical Education and Research (PGIMER), Chandigarh, India
| | - Bhavana Rai
- Department of Radiotherapy and Oncology, Post Graduate Institute of Medical Education and Research (PGIMER), Chandigarh, India
| | - Arun Singh Oinam
- Department of Radiotherapy and Oncology, Post Graduate Institute of Medical Education and Research (PGIMER), Chandigarh, India
| | - Rahul krishnatry
- Department of Radiation Oncology, Tata Memorial Hospital, Mumbai, India
| | - Bhaswanth Dhanireddy
- Department of Radiotherapy and Oncology, Post Graduate Institute of Medical Education and Research (PGIMER), Chandigarh, India
| |
Collapse
|
119
|
Mattes MD, Lee JC, Elnaiem S, Guirguis A, Ikoro NC, Ashamalla H. A predictive model to guide management of the overlap region between target volume and organs at risk in prostate cancer volumetric modulated arc therapy. Radiat Oncol J 2014; 32:23-30. [PMID: 24724048 PMCID: PMC3977128 DOI: 10.3857/roj.2014.32.1.23] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2013] [Revised: 12/20/2013] [Accepted: 01/16/2014] [Indexed: 12/20/2022] Open
Abstract
PURPOSE The goal of this study is to determine whether the magnitude of overlap between planning target volume (PTV) and rectum (Rectumoverlap) or PTV and bladder (Bladderoverlap) in prostate cancer volumetric-modulated arc therapy (VMAT) is predictive of the dose-volume relationships achieved after optimization, and to identify predictive equations and cutoff values using these overlap volumes beyond which the Quantitative Analyses of Normal Tissue Effects in the Clinic (QUANTEC) dose-volume constraints are unlikely to be met. MATERIALS AND METHODS Fifty-seven patients with prostate cancer underwent VMAT planning using identical optimization conditions and normalization. The PTV (for the 50.4 Gy primary plan and 30.6 Gy boost plan) included 5 to 10 mm margins around the prostate and seminal vesicles. Pearson correlations, linear regression analyses, and receiver operating characteristic (ROC) curves were used to correlate the percentage overlap with dose-volume parameters. RESULTS The percentage Rectumoverlap and Bladderoverlap correlated with sparing of that organ but minimally impacted other dose-volume parameters, predicted the primary plan rectum V45 and bladder V50 with R(2) = 0.78 and R(2) = 0.83, respectively, and predicted the boost plan rectum V30 and bladder V30 with R(2) = 0.53 and R(2) = 0.81, respectively. The optimal cutoff value of boost Rectumoverlap to predict rectum V75 >15% was 3.5% (sensitivity 100%, specificity 94%, p < 0.01), and the optimal cutoff value of boost Bladderoverlap to predict bladder V80 >10% was 5.0% (sensitivity 83%, specificity 100%, p < 0.01). CONCLUSION The degree of overlap between PTV and bladder or rectum can be used to accurately guide physicians on the use of interventions to limit the extent of the overlap region prior to optimization.
Collapse
Affiliation(s)
- Malcolm D Mattes
- Department of Radiation Oncology, New York Methodist Hospital, Brooklyn, NY, USA
| | - Jennifer C Lee
- Department of Radiation Oncology, New York Methodist Hospital, Brooklyn, NY, USA
| | - Sara Elnaiem
- Department of Radiation Oncology, New York Methodist Hospital, Brooklyn, NY, USA
| | - Adel Guirguis
- Department of Radiation Oncology, New York Methodist Hospital, Brooklyn, NY, USA
| | - N C Ikoro
- Department of Radiation Oncology, New York Methodist Hospital, Brooklyn, NY, USA
| | - Hani Ashamalla
- Department of Radiation Oncology, New York Methodist Hospital, Brooklyn, NY, USA
| |
Collapse
|
120
|
Jaussaud S, Guihard S, Niederst C, Borel C, Meyer P, Hémar P, Schultz P, Noël G, Féki A. [Constraints of the dentist are consistent with the results of an optimal irradiation with modulated intensity in N0 oropharyngeal cancer]. Cancer Radiother 2013; 17:265-71. [PMID: 23726044 DOI: 10.1016/j.canrad.2013.01.020] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2012] [Revised: 12/26/2012] [Accepted: 01/31/2013] [Indexed: 10/26/2022]
Abstract
PURPOSE We compared intensity-modulated radiotherapy and 3D-conformal irradiation in oropharyngeal cancers according to the requirement of dentists. MATERIAL AND METHODS From the files of seven patients with cancer of the oropharynx, two dosimetry plannings for 3D-conformal radiotherapy and intensity-modulated radiotherapy with tomotherapy were performed. The dose distributions in the target volumes and organs at risk in relation to the dental sphere were compared. RESULTS For the planning target volume of the primitive tumour sites, average values of V95%, D2%, D98% and of the conformal index were statistically in favour of tomotherapy. For the planning target volume of node areas, averages values of V95%, D2%, D98% were statistically in favour of tomotherapy. For ipsi- and controlateral parotide glands, average values of V15Gy, V26Gy, V30Gy, V40Gy were significantly lower for tomotherapy. For the submaxillary glands, average values of mean doses and V40Gy were statistically in favour of tomotherapy. For the buccal cavity, the average values of V45Gy were statistically in favour of tomotherapy. For ipsi- and controlateral masseter muscles, the average values of mean doses were statistically in favour of tomotherapy. For the ipsi- and controlateral temporomandibular joints, average values of mean doses and V60Gy were statistically in favour of tomotherapy. For mandibular bone, average values of mean doses and V40Gy, V50Gy, V60Gy and V70Gy were statistically in favour of tomotherapy. For maxillary bone, average values of V40Gy, V50Gy and V60Gy were statistically in favour of tomotherapy. CONCLUSION The radiation oncologist can constrain the intensity-modulated radiotherapy dosimetry to the needs of dentists to prevent or improve dental care and quality of life.
Collapse
Affiliation(s)
- S Jaussaud
- Faculté Dentaire, Hôpital Civil, 67000 Strasbourg, France
| | | | | | | | | | | | | | | | | |
Collapse
|
121
|
Fung-Kee-Fung SD, Hackett R, Hales L, Warren G, Singh AK. A prospective trial of volumetric intensity-modulated arc therapy vs conventional intensity modulated radiation therapy in advanced head and neck cancer. World J Clin Oncol 2012; 3:57-62. [PMID: 22553505 PMCID: PMC3341741 DOI: 10.5306/wjco.v3.i4.57] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/26/2011] [Revised: 02/15/2012] [Accepted: 04/01/2012] [Indexed: 02/06/2023] Open
Abstract
AIM: To prospectively compare volumetric intensity-modulated arc therapy (VMAT) and conventional intensity-modulated radiation therapy (IMRT) in coverage of planning target volumes and avoidance of multiple organs at risk (OARs) in patients undergoing definitive chemoradiotherapy for advanced (stage III or IV) squamous cell cancer of the head and neck.
METHODS: Computed tomography scans of 20 patients with advanced tumors of the larynx, naso-, oro- and hypopharynx were prospectively planned using IMRT (7 field) and VMAT using two arcs. Calculated doses to planning target volume (PTV) and OAR were compared between IMRT and VMAT plans. Dose-volume histograms (DVH) were utilized to obtain calculated doses to PTV and OAR, including parotids, cochlea, spinal cord, brainstem, anterior tongue, pituitary and brachial plexus. DVH’s for all structures were compared between IMRT and VMAT plans. In addition the plans were compared for dose conformity and homogeneity. The final treatment plan was chosen by the treating radiation oncologist.
RESULTS: VMAT was chosen as the ultimate plan in 18 of 20 patients (90%) because the plans were thought to be otherwise clinically equivalent. The IMRT plan was chosen in 2 of 20 patients because the VMAT plan produced concentric irradiation of the cord which was not overcome even with an avoidance structure. For all patients, VMAT plans had a lower number of average monitor units on average (MU = 542.85) than IMRT plans (MU = 1612.58) (P < 0.001). Using the conformity index (CI), defined as the 95% isodose volume divided by the PTV, the IMRT plan was more conformal with a lower conformity index (CI = 1.61) than the VMAT plan (CI = 2.00) (P = 0.003). Dose homogeneity, as measured by average standard deviation of dose distribution over the PTV, was not different with VMAT (1.45 Gy) or IMRT (1.73 Gy) (P = 0.069). There were no differences in sparing organs at risk.
CONCLUSION: In this prospective study, VMAT plans were chosen over IMRT 90% of the time. Compared to IMRT, VMAT plans used only one third of the MUs, had shorter treatment times, and similar sparing of OAR. Overall, VMAT provided similar dose homogeneity but less conformity in PTV irradiation compared to IMRT. This difference in conformity was not clinically significant.
Collapse
Affiliation(s)
- Simon D Fung-Kee-Fung
- Simon D Fung-Kee-Fung, Rachel Hackett, Lee Hales, Graham Warren, Anurag K Singh, Department of Radiation Medicine, Roswell Park Cancer Institute, University at Buffalo School of Medicine, Elm and Carlton Streets, Buffalo, NY 14214, United States
| | | | | | | | | |
Collapse
|