Kurland BF, Muzi M, Peterson LM, Doot RK, Wangerin KA, Mankoff DA, Linden HM, Kinahan PE. Multicenter Clinical Trials Using 18F-FDG PET to Measure Early Response to Oncologic Therapy: Effects of Injection-to-Acquisition Time Variability on Required Sample Size. J Nucl Med 2015; 57:226-30. [PMID: 26493206 DOI: 10.2967/jnumed.115.162289] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2015] [Accepted: 10/13/2015] [Indexed: 01/27/2023] Open
Abstract
UNLABELLED Uptake time (interval between tracer injection and image acquisition) affects the SUV measured for tumors in (18)F-FDG PET images. With dissimilar uptake times, changes in tumor SUVs will be under- or overestimated. This study examined the influence of uptake time on tumor response assessment using a virtual clinical trials approach. METHODS Tumor kinetic parameters were estimated from dynamic (18)F-FDG PET scans of breast cancer patients and used to simulate time-activity curves for 45-120 min after injection. Five-minute uptake time frames followed 4 scenarios: the first was a standardized static uptake time (the SUV from 60 to 65 min was selected for all scans), the second was uptake times sampled from an academic PET facility with strict adherence to standardization protocols, the third was a distribution similar to scenario 2 but with greater deviation from standards, and the fourth was a mixture of hurried scans (45- to 65-min start of image acquisition) and frequent delays (58- to 115-min uptake time). The proportion of out-of-range scans (<50 or >70 min, or >15-min difference between paired scans) was 0%, 20%, 44%, and 64% for scenarios 1, 2, 3, and 4, respectively. A published SUV correction based on local linearity of uptake-time dependence was applied in a separate analysis. Influence of uptake-time variation was assessed as sensitivity for detecting response (probability of observing a change of ≥30% decrease in (18)F-FDG PET SUV given a true decrease of 40%) and specificity (probability of observing an absolute change of <30% given no true change). RESULTS Sensitivity was 96% for scenario 1, and ranged from 73% for scenario 4 (95% confidence interval, 70%-76%) to 92% (90%-93%) for scenario 2. Specificity for all scenarios was at least 91%. Single-arm phase II trials required an 8%-115% greater sample size for scenarios 2-4 than for scenario 1. If uptake time is known, SUV correction methods may raise sensitivity to 87%-95% and reduce the sample size increase to less than 27%. CONCLUSION Uptake-time deviations from standardized protocols occur frequently, potentially decreasing the performance of (18)F-FDG PET response biomarkers. Correcting SUV for uptake time improves sensitivity, but algorithm refinement is needed. Stricter uptake-time control and effective correction algorithms could improve power and decrease costs for clinical trials using (18)F-FDG PET endpoints.
Collapse
|
77
|
Rui X, Cheng L, Long Y, Fu L, Alessio AM, Asma E, Kinahan PE, De Man B. Ultra-low dose CT attenuation correction for PET/CT: analysis of sparse view data acquisition and reconstruction algorithms. Phys Med Biol 2015; 60:7437-60. [PMID: 26352168 PMCID: PMC5260824 DOI: 10.1088/0031-9155/60/19/7437] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
For PET/CT systems, PET image reconstruction requires corresponding CT images for anatomical localization and attenuation correction. In the case of PET respiratory gating, multiple gated CT scans can offer phase-matched attenuation and motion correction, at the expense of increased radiation dose. We aim to minimize the dose of the CT scan, while preserving adequate image quality for the purpose of PET attenuation correction by introducing sparse view CT data acquisition.We investigated sparse view CT acquisition protocols resulting in ultra-low dose CT scans designed for PET attenuation correction. We analyzed the tradeoffs between the number of views and the integrated tube current per view for a given dose using CT and PET simulations of a 3D NCAT phantom with lesions inserted into liver and lung. We simulated seven CT acquisition protocols with {984, 328, 123, 41, 24, 12, 8} views per rotation at a gantry speed of 0.35 s. One standard dose and four ultra-low dose levels, namely, 0.35 mAs, 0.175 mAs, 0.0875 mAs, and 0.043 75 mAs, were investigated. Both the analytical Feldkamp, Davis and Kress (FDK) algorithm and the Model Based Iterative Reconstruction (MBIR) algorithm were used for CT image reconstruction. We also evaluated the impact of sinogram interpolation to estimate the missing projection measurements due to sparse view data acquisition. For MBIR, we used a penalized weighted least squares (PWLS) cost function with an approximate total-variation (TV) regularizing penalty function. We compared a tube pulsing mode and a continuous exposure mode for sparse view data acquisition. Global PET ensemble root-mean-squares-error (RMSE) and local ensemble lesion activity error were used as quantitative evaluation metrics for PET image quality.With sparse view sampling, it is possible to greatly reduce the CT scan dose when it is primarily used for PET attenuation correction with little or no measureable effect on the PET image. For the four ultra-low dose levels simulated, sparse view protocols with 41 and 24 views best balanced the tradeoff between electronic noise and aliasing artifacts. In terms of lesion activity error and ensemble RMSE of the PET images, these two protocols, when combined with MBIR, are able to provide results that are comparable to the baseline full dose CT scan. View interpolation significantly improves the performance of FDK reconstruction but was not necessary for MBIR. With the more technically feasible continuous exposure data acquisition, the CT images show an increase in azimuthal blur compared to tube pulsing. However, this blurring generally does not have a measureable impact on PET reconstructed images.Our simulations demonstrated that ultra-low-dose CT-based attenuation correction can be achieved at dose levels on the order of 0.044 mAs with little impact on PET image quality. Highly sparse 41- or 24- view ultra-low dose CT scans are feasible for PET attenuation correction, providing the best tradeoff between electronic noise and view aliasing artifacts. The continuous exposure acquisition mode could potentially be implemented in current commercially available scanners, thus enabling sparse view data acquisition without requiring x-ray tubes capable of operating in a pulsing mode.
Collapse
|
78
|
Nyflot MJ, Yang F, Byrd D, Bowen SR, Sandison GA, Kinahan PE. Quantitative radiomics: impact of stochastic effects on textural feature analysis implies the need for standards. J Med Imaging (Bellingham) 2015; 2:041002. [PMID: 26251842 PMCID: PMC4524811 DOI: 10.1117/1.jmi.2.4.041002] [Citation(s) in RCA: 105] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2015] [Accepted: 06/02/2015] [Indexed: 11/14/2022] Open
Abstract
Image heterogeneity metrics such as textural features are an active area of research for evaluating clinical outcomes with positron emission tomography (PET) imaging and other modalities. However, the effects of stochastic image acquisition noise on these metrics are poorly understood. We performed a simulation study by generating 50 statistically independent PET images of the NEMA IQ phantom with realistic noise and resolution properties. Heterogeneity metrics based on gray-level intensity histograms, co-occurrence matrices, neighborhood difference matrices, and zone size matrices were evaluated within regions of interest surrounding the lesions. The impact of stochastic variability was evaluated with percent difference from the mean of the 50 realizations, coefficient of variation and estimated sample size for clinical trials. Additionally, sensitivity studies were performed to simulate the effects of patient size and image reconstruction method on the quantitative performance of these metrics. Complex trends in variability were revealed as a function of textural feature, lesion size, patient size, and reconstruction parameters. In conclusion, the sensitivity of PET textural features to normal stochastic image variation and imaging parameters can be large and is feature-dependent. Standards are needed to ensure that prospective studies that incorporate textural features are properly designed to measure true effects that may impact clinical outcomes.
Collapse
|
79
|
Harkness BA, Allison JD, Clements JB, Coffey CW, Fahey FH, Gress DA, Kinahan PE, Nickoloff EL, Mawlawi OR, MacDougall RD, Pizzutiello RJ. AAPM/SNMMI Joint Task Force: report on the current state of nuclear medicine physics training. J Appl Clin Med Phys 2015; 16:3-13. [PMID: 26699325 PMCID: PMC5690174 DOI: 10.1120/jacmp.v16i5.5661] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2015] [Revised: 04/28/2015] [Accepted: 04/08/2015] [Indexed: 11/23/2022] Open
Abstract
The American Association of Physicists in Medicine (AAPM) and the Society of Nuclear Medicine and Molecular Imaging (SNMMI) recognized the need for a review of the current state of nuclear medicine physics training and the need to explore pathways for improving nuclear medicine physics training opportunities. For these reasons, the two organizations formed a joint AAPM/SNMMI Ad Hoc Task Force on Nuclear Medicine Physics Training. The mission of this task force was to assemble a representative group of stakeholders to:• Estimate the demand for board-certified nuclear medicine physicists in the next 5-10 years,• Identify the critical issues related to supplying an adequate number of physicists who have received the appropriate level of training in nuclear medicine physics, and• Identify approaches that may be considered to facilitate the training of nuclear medicine physicists.As a result, a task force was appointed and chaired by an active member of both organizations that included representation from the AAPM, SNMMI, the American Board of Radiology (ABR), the American Board of Science in Nuclear Medicine (ABSNM), and the Commission for the Accreditation of Medical Physics Educational Programs (CAMPEP). The Task Force first met at the AAPM Annual Meeting in Charlotte in July 2012 and has met regularly face-to-face, online, and by conference calls. This manuscript reports the findings of the Task Force, as well as recommendations to achieve the stated mission.
Collapse
|
80
|
Wangerin KA, Muzi M, Peterson LM, Linden HM, Novakova A, O'Sullivan F, Kurland BF, Mankoff DA, Kinahan PE. Effect of 18F-FDG uptake time on lesion detectability in PET imaging of early stage breast cancer. Tomography 2015; 1:53-60. [PMID: 26807443 PMCID: PMC4721230 DOI: 10.18383/j.tom.2015.00151] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Prior reports have suggested that delayed FDG-PET oncology imaging can improve the contrast-to-noise ratio (CNR) for known lesions. Our goal was to estimate realistic bounds for lesion detectability for static measurements with one to four hours between FDG injection and image acquisition. Tumor and normal tissue kinetic model parameters were estimated from dynamic PET studies of patients with early stage breast cancer. These were used to generate time-activity curves (TACs) out to four hours, for which we assumed both nonreversible and reversible models with different rates of FDG dephosphorylation (k4). For each pair of tumor and normal tissue TACs, 600 PET sinogram realizations were generated, and images were reconstructed using OSEM. Test statistics for each tumor and normal tissue region of interest were output from the computer model observers and evaluated using an ROC analysis with the calculated AUC providing a measure of lesion detectability. For the nonreversible model (k4 = 0), the AUC increased in 11/23 (48%) of patients for one to two hours after the current standard post-radiotracer injection imaging window of one hour. This improvement was driven by increased tumor/normal tissue contrast before the impact of increased noise due to radiotracer decay began to dominate the imaging signal. As k4 was increased from 0 to 0.01 min-1, the time of maximum detectability shifted earlier, as the decreasing FDG concentration in the tumor lowered the CNR. These results imply that delayed PET imaging may reveal low-conspicuity lesions that would have otherwise gone undetected.
Collapse
|
81
|
Nyflot MJ, Lee TC, Alessio AM, Wollenweber SD, Stearns CW, Bowen SR, Kinahan PE. Impact of CT attenuation correction method on quantitative respiratory-correlated (4D) PET/CT imaging. Med Phys 2015; 42:110-20. [PMID: 25563252 DOI: 10.1118/1.4903282] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Respiratory-correlated positron emission tomography (PET/CT) 4D PET/CT is used to mitigate errors from respiratory motion; however, the optimal CT attenuation correction (CTAC) method for 4D PET/CT is unknown. The authors performed a phantom study to evaluate the quantitative performance of CTAC methods for 4D PET/CT in the ground truth setting. METHODS A programmable respiratory motion phantom with a custom movable insert designed to emulate a lung lesion and lung tissue was used for this study. The insert was driven by one of five waveforms: two sinusoidal waveforms or three patient-specific respiratory waveforms. 3DPET and 4DPET images of the phantom under motion were acquired and reconstructed with six CTAC methods: helical breath-hold (3DHEL), helical free-breathing (3DMOT), 4D phase-averaged (4DAVG), 4D maximum intensity projection (4DMIP), 4D phase-matched (4DMATCH), and 4D end-exhale (4DEXH) CTAC. Recovery of SUV(max), SUV(mean), SUV(peak), and segmented tumor volume was evaluated as RC(max), RC(mean), RC(peak), and RC(vol), representing percent difference relative to the static ground truth case. Paired Wilcoxon tests and Kruskal-Wallis ANOVA were used to test for significant differences. RESULTS For 4DPET imaging, the maximum intensity projection CTAC produced significantly more accurate recovery coefficients than all other CTAC methods (p < 0.0001 over all metrics). Over all motion waveforms, ratios of 4DMIP CTAC recovery were 0.2 ± 5.4, -1.8 ± 6.5, -3.2 ± 5.0, and 3.0 ± 5.9 for RC(max), RC(peak), RC(mean), and RC(vol). In comparison, recovery coefficients for phase-matched CTAC were -8.4 ± 5.3, -10.5 ± 6.2, -7.6 ± 5.0, and -13.0 ± 7.7 for RC(max), RC(peak), RC(mean), and RC(vol). When testing differences between phases over all CTAC methods and waveforms, end-exhale phases were significantly more accurate (p = 0.005). However, these differences were driven by the patient-specific respiratory waveforms; when testing patient and sinusoidal waveforms separately, patient waveforms were significantly different between phases (p < 0.0001) while the sinusoidal waveforms were not significantly different (p = 0.98). When considering only the subset of 4DMATCH images that corresponded to the end-exhale image phase, 4DEXH, mean and interquartile range were similar to 4DMATCH but variability was considerably reduced. CONCLUSIONS Comparative advantages in accuracy and precision of SUV metrics and segmented volumes were demonstrated with the use of the maximum intensity projection and end-exhale CT attenuation correction. While respiratory phase-matched CTAC should in theory provide optimal corrections, image artifacts and differences in implementation of 4DCT and 4DPET sorting can degrade the benefit of this approach. These results may be useful to guide the implementation, analysis, and development of respiratory-correlated thoracic PET/CT in the radiation oncology and diagnostic settings.
Collapse
|
82
|
Nyflot MJ, Yang F, Byrd D, Bowen SR, Sandison GA, Kinahan PE. TU-AB-BRA-04: Quantitative Radiomics: Sensitivity of PET Textural Features to Image Acquisition and Reconstruction Parameters Implies the Need for Standards. Med Phys 2015. [DOI: 10.1118/1.4925509] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
83
|
Kinahan PE, Mankoff DA, Linden HM. The Value of Establishing the Quantitative Accuracy of PET/CT Imaging. J Nucl Med 2015; 56:1133-4. [PMID: 26089552 DOI: 10.2967/jnumed.115.159178] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2015] [Accepted: 05/14/2015] [Indexed: 11/16/2022] Open
|
84
|
Pierce LA, Elston BF, Clunie DA, Nelson D, Kinahan PE. A Digital Reference Object to Analyze Calculation Accuracy of PET Standardized Uptake Value. Radiology 2015; 277:538-45. [PMID: 25989387 DOI: 10.1148/radiol.2015141262] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To determine the extent of variations in computing standardized uptake value (SUV) by body weight (SUV(BW)) among different software packages and to propose a Digital Imaging and Communications in Medicine (DICOM) reference test object to ensure the standardization of SUV computation between medical image viewing workstations. MATERIALS AND METHODS Research ethics board approval was not necessary because this study only evaluated images of a phantom. A synthetic set of positron emission tomographic (PET)/computed tomographic (CT) image data, called a digital reference object (DRO), with known SUV was created. The DRO was sent to 16 sites and evaluated on 21 different PET/CT display software packages. Users were asked to draw various regions of interest (ROIs) on specific features and report the maximum, minimum, mean, and standard deviation of the SUVs for each ROI. Numerical tolerances were defined for each metric, and the fraction of reported values within the tolerance was recorded, as was the mean, standard deviation, and range of the metrics. RESULTS The errors in reported maximum SUV ranged from -37.8% to 0% for an isolated voxel with 4.11:1 target-to-background activity level, and errors in the reported mean SUV ranged from -1.6% to 100% for a region with controlled noise. There was also a range of errors in the less commonly used metrics of minimum SUV and standard deviation SUV. CONCLUSION The variability of computed SUV(BW) between different software packages is substantial enough to warrant the introduction of a reference standard for medical image viewing workstations.
Collapse
|
85
|
Bowen SR, Saini J, Chapman TR, Miyaoka RS, Kinahan PE, Sandison GA, Wong T, Vesselle HJ, Nyflot MJ, Apisarnthanarax S. Differential hepatic avoidance radiation therapy: Proof of concept in hepatocellular carcinoma patients. Radiother Oncol 2015; 115:203-10. [PMID: 25934165 DOI: 10.1016/j.radonc.2015.04.011] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2014] [Revised: 03/16/2015] [Accepted: 04/03/2015] [Indexed: 12/23/2022]
Abstract
PURPOSE To evaluate the feasibility of a novel planning concept that differentially redistributes RT dose away from functional liver regions as defined by (99m)Tc-sulphur colloid (SC) uptake on patient SPECT/CT images. MATERIALS AND METHODS Ten HCC patients with different Child-Turcotte-Pugh scores (A5-B9) underwent SC SPECT/CT scans in treatment position prior to RT that were registered to planning CT scans. Proton pencil beam scanning (PBS) therapy plans were optimized to deliver 37.5-60.0Gy (RBE) over 5-15 fractions using single field uniform dose technique robust to range and setup uncertainty. Photon volumetrically modulated arc therapy (VMAT) plans were optimized to the same prescribed dose and minimum target coverage. For both treatment modalities, differential hepatic avoidance RT (DHART) plans were generated to decrease dose to functional liver volumes (FLV) defined by a range of thresholds relative to maximum SC uptake (43-90%) in the tumor-subtracted liver. Radiation dose was redistributed away from regions of increased SC uptake in each FLV by linearly scaling mean dose objectives during PBS or VMAT optimization. DHART planning feasibility was assessed by a significantly negative Spearman's rank correlation (RS) between dose difference and SC uptake. Patient, tumor, and treatment planning characteristics were tested for association to DHART planning feasibility using non-parametric Kruskal-Wallis ANOVA. RESULTS Compared to conventional plans, DHART plans achieved a 3% FLV dose reduction for every 10% SC uptake increase. DHART planning was feasible in the majority of patients with 60% of patients having RS<-0.5 (p<0.01, range -1.0 to 0.2) and was particularly effective in 30% of patients (RS<-0.9). Mean dose to FLV was reduced by up to 20% in these patients. Only fractionation regimen was associated with DHART planning feasibility: 15 fraction courses were more feasible than 5-6 fraction courses (RS<-0.93 vs. RS>-0.60, p<0.02). CONCLUSION Differential avoidance of functional liver regions defined on sulphur colloid SPECT/CT is achievable with either photon VMAT or proton PBS therapy. Further investigation with phantom studies and in a larger cohort of patients may validate the utility of DHART planning for HCC radiotherapy.
Collapse
|
86
|
Bowen SR, Nyflot MJ, Herrmann C, Groh CM, Meyer J, Wollenweber SD, Stearns CW, Kinahan PE, Sandison GA. Imaging and dosimetric errors in 4D PET/CT-guided radiotherapy from patient-specific respiratory patterns: a dynamic motion phantom end-to-end study. Phys Med Biol 2015; 60:3731-46. [PMID: 25884892 DOI: 10.1088/0031-9155/60/9/3731] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Effective positron emission tomography / computed tomography (PET/CT) guidance in radiotherapy of lung cancer requires estimation and mitigation of errors due to respiratory motion. An end-to-end workflow was developed to measure patient-specific motion-induced uncertainties in imaging, treatment planning, and radiation delivery with respiratory motion phantoms and dosimeters. A custom torso phantom with inserts mimicking normal lung tissue and lung lesion was filled with [(18)F]FDG. The lung lesion insert was driven by six different patient-specific respiratory patterns or kept stationary. PET/CT images were acquired under motionless ground truth, tidal breathing motion-averaged (3D), and respiratory phase-correlated (4D) conditions. Target volumes were estimated by standardized uptake value (SUV) thresholds that accurately defined the ground-truth lesion volume. Non-uniform dose-painting plans using volumetrically modulated arc therapy were optimized for fixed normal lung and spinal cord objectives and variable PET-based target objectives. Resulting plans were delivered to a cylindrical diode array at rest, in motion on a platform driven by the same respiratory patterns (3D), or motion-compensated by a robotic couch with an infrared camera tracking system (4D). Errors were estimated relative to the static ground truth condition for mean target-to-background (T/Bmean) ratios, target volumes, planned equivalent uniform target doses, and 2%-2 mm gamma delivery passing rates. Relative to motionless ground truth conditions, PET/CT imaging errors were on the order of 10-20%, treatment planning errors were 5-10%, and treatment delivery errors were 5-30% without motion compensation. Errors from residual motion following compensation methods were reduced to 5-10% in PET/CT imaging, <5% in treatment planning, and <2% in treatment delivery. We have demonstrated that estimation of respiratory motion uncertainty and its propagation from PET/CT imaging to RT planning, and RT delivery under a dose painting paradigm is feasible within an integrated respiratory motion phantom workflow. For a limited set of cases, the magnitude of errors was comparable during PET/CT imaging and treatment delivery without motion compensation. Errors were moderately mitigated during PET/CT imaging and significantly mitigated during RT delivery with motion compensation. This dynamic motion phantom end-to-end workflow provides a method for quality assurance of 4D PET/CT-guided radiotherapy, including evaluation of respiratory motion compensation methods during imaging and treatment delivery.
Collapse
|
87
|
Graham MM, Wahl RL, Hoffman JM, Yap JT, Sunderland JJ, Boellaard R, Perlman ES, Kinahan PE, Christian PE, Hoekstra OS, Dorfman GS. Summary of the UPICT Protocol for 18F-FDG PET/CT Imaging in Oncology Clinical Trials. J Nucl Med 2015; 56:955-61. [PMID: 25883122 DOI: 10.2967/jnumed.115.158402] [Citation(s) in RCA: 84] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2015] [Accepted: 03/27/2015] [Indexed: 01/05/2023] Open
Abstract
The Uniform Protocols for Imaging in Clinical Trials (UPICT) (18)F-FDG PET/CT protocol is intended to guide the performance of whole-body FDG PET/CT studies within the context of single- and multiple-center clinical trials of oncologic therapies by providing acceptable (minimum), target, and ideal standards for all phases of imaging. The aim is to minimize variability in intra- and intersubject, intra- and interplatform, interexamination, and interinstitutional primary or derived data. The goal of this condensed version of the much larger document is to make readers aware of the general content and subject area. The document has several main subjects: context of the imaging protocol within the clinical trial; site selection, qualification, and training; subject scheduling; subject preparation; imaging-related substance preparation and administration; imaging procedure; image postprocessing; image analysis; image interpretation; archiving and distribution of data; quality control; and imaging-associated risks and risk management.
Collapse
|
88
|
Abstract
Lung diseases cause significant morbidity and mortality and lead to high healthcare utilization. However, few lung disease-specific biomarkers are available to accurately monitor disease activity for the purposes of clinical management or drug development. Advances in cross-modal imaging technologies, such as combined positron emission tomography (PET) and magnetic resonance (MR) imaging scanners and PET or single-photon emission computed tomography (SPECT) combined with computed tomography (CT), may aid in the development of noninvasive, molecular-based biomarkers for lung disease. However, the lungs pose particular challenges in obtaining accurate quantification of imaging data due to the low density of the organ and breathing motion. This review covers the basic physics underlying PET, SPECT, CT, and MR lung imaging and presents technical considerations for multimodal imaging with regard to PET and SPECT quantification. It also includes a brief review of the current and potential clinical applications for these hybrid imaging technologies.
Collapse
|
89
|
Tashima H, Yamaya T, Kinahan PE. An OpenPET scanner with bridged detectors to compensate for incomplete data. Phys Med Biol 2014; 59:6175-93. [PMID: 25255296 DOI: 10.1088/0031-9155/59/20/6175] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
We are developing an open-type PET 'OpenPET' geometry. One possible geometry is a dual-ring OpenPET, which consists of two detector rings separated by a gap for entrance of a radiotherapy beam or for inserting other modalities. In our previous simulations and experiments the OpenPET imaging geometry was shown to be feasible by applying iterative reconstruction methods. However, the gap violates Orlov's completeness condition for accurate tomographic reconstruction. In this study, we propose a solution for the incompleteness problem by adding bridge detectors to fill in parts of the gaps of the OpenPET geometry; we call this bridged OpenPET. Although this geometry was considered previously, its analytical property was not discussed. Therefore, we applied the direct Fourier method as an analytical reconstruction method to the bridged OpenPET, dual-ring OpenPET and conventional cylindrical PET for comparison. Numerical simulations showed that the additional bridge detectors compensate for the incompleteness of the OpenPET by covering one direction perpendicular to the transaxial slices of the imaging subjects.
Collapse
|
90
|
Bowen SR, Pierce LA, Alessio AM, Liu C, Wollenweber SD, Stearns CW, Kinahan PE. Assessment of patient selection criteria for quantitative imaging with respiratory-gated positron emission tomography. J Med Imaging (Bellingham) 2014; 1:026001. [PMID: 26158039 DOI: 10.1117/1.jmi.1.2.026001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2014] [Revised: 09/03/2014] [Accepted: 09/03/2014] [Indexed: 12/25/2022] Open
Abstract
The objective of this investigation was to propose techniques for determining which patients are likely to benefit from quantitative respiratory-gated imaging by correlating respiratory patterns to changes in positron emission tomography (PET) metrics. Twenty-six lung and liver cancer patients underwent PET/computed tomography exams with recorded chest/abdominal displacements. Static and adaptive amplitude-gated [[Formula: see text]]fluoro-D-glucose (FDG) PET images were generated from list-mode acquisitions. Patients were grouped by respiratory pattern, lesion location, or degree of lesion attachment to anatomical structures. Respiratory pattern metrics were calculated during time intervals corresponding to PET field of views over lesions of interest. FDG PET images were quantified by lesion maximum standardized uptake value ([Formula: see text]). Relative changes in [Formula: see text] between static and gated PET images were tested for association to respiratory pattern metrics. Lower lung lesions and liver lesions had significantly higher changes in [Formula: see text] than upper lung lesions (14 versus 3%, [Formula: see text]). Correlation was highest ([Formula: see text], [Formula: see text], [Formula: see text]) between changes in [Formula: see text] and nonstandard respiratory pattern metrics. Lesion location had a significant impact on changes in PET quantification due to respiratory gating. Respiratory pattern metrics were correlated to changes in [Formula: see text], though sample size limited statistical power. Validation in larger cohorts may enable selection of patients prior to acquisition who would benefit from respiratory-gated PET imaging.
Collapse
|
91
|
Pierce LA, Hunter WCJ, Haynor DR, MacDonald LR, Kinahan PE, Miyaoka RS. Multiplexing strategies for monolithic crystal PET detector modules. Phys Med Biol 2014; 59:5347-60. [PMID: 25146849 PMCID: PMC4157903 DOI: 10.1088/0031-9155/59/18/5347] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
To reduce the number of output channels and associated cost in PET detectors, strategies to multiplex the signal channels have been investigated by several researchers. This work aims to find an optimal multiplexing strategy for detector modules consisting of a monolithic LYSO scintillator coupled to a 64-channel PMT. We apply simulated multiplexing strategies to measured data from two continuous miniature crystal element (cMiCE) detector modules. The strategies tested include standard methods such as row column summation and its variants, as well as new data-driven methods involving the principal components of measured data and variants of those components. The detector positioning resolution and bias are measured for each multiplexing strategy and the results are compared. The mean FWHM over the entire detector was 1.23 mm for no multiplexing (64 channels). Using 16 principal component channels yielded a mean FWHM resolution of 1.21 mm, while traditional row/column summation (16 channels) yielded 1.28 mm. Using 8 principal component output channels resulted in a resolution of 1.30 mm. Using the principal components of the calibration data to guide the multiplexing scheme appears to be a viable method for reducing the number of output data channels. Further study is needed to determine if the depth-of-interaction resolution can be preserved with this multiplexing scheme.
Collapse
|
92
|
Xia T, Alessio AM, Kinahan PE. Dual energy CT for attenuation correction with PET/CT. Med Phys 2014; 41:012501. [PMID: 24387525 DOI: 10.1118/1.4828838] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023] Open
Abstract
PURPOSE The authors evaluate the energy dependent noise and bias properties of monoenergetic images synthesized from dual-energy CT (DECT) acquisitions. These monoenergetic images can be used to estimate attenuation coefficients at energies suitable for positron emission tomography (PET) and single-photon emission computed tomography (SPECT) imaging. This is becoming more relevant with the increased use of quantitative imaging by PET/CT and SPECT/CT scanners. There are, however, potential variations in the noise and bias of synthesized monoenergetic images as a function of energy. METHODS The authors used analytic approximations and simulations to estimate the noise and bias of synthesized monoenergetic images of water-filled cylinders with different shapes and the NURBS-based cardiac-torso (NCAT) phantom from 40 to 520 keV, the range of SPECT and PET energies. The dual-kVp spectra were based on the GE Lightspeed VCT scanner at 80 and 140 kVp with added filtration of 0.5 mm Cu. The authors evaluated strategies of noise suppression with sinogram smoothing and dose minimization with reduction of tube currents at the two kVp settings. The authors compared the impact of DECT-based attenuation correction with single-kVp CT-based attenuation correction on PET quantitation for the NCAT phantom for soft tissue and high-Z materials of bone and iodine contrast enhancement. RESULTS Both analytic calculations and simulations displayed the expected minimum noise value for a synthesized monoenergetic image at an energy between the mean energies of the two spectra. In addition the authors found that the normalized coefficient of variation in the synthesized attenuation map increased with energy but reached a plateau near 160 keV, and then remained constant with increasing energy up to 511 keV and beyond. The bias was minimal, as the linear attenuation coefficients of the synthesized monoenergetic images were within 2.4% of the known true values across the entire energy range. Compared with no sinogram smoothing, sinogram smoothing can dramatically reduce noise in the DECT-derived attenuation map. Through appropriate selection of tube currents for high and low kVp scans, DECT can deliver roughly the same amount of radiation dose as that of a single kVp CT scan, but could be used for PET attenuation correction with reduced bias in contrast agent regions by a factor of ≈ 2.6 and slightly reduced RMSE for the total image. CONCLUSIONS When DECT is used for attenuation correction at higher energies, there is a noise amplification that is dependent on the energy of the synthesized monoenergetic image of linear attenuation coefficients. Sinogram smoothing reduces the noise amplification in DECT-derived attenuation maps without increasing bias. With an appropriate selection of CT techniques, a DECT scan with the same radiation dose as a single CT scan can result in a PET image with improved quantitative accuracy.
Collapse
|
93
|
Obuchowski NA, Reeves AP, Huang EP, Wang XF, Buckler AJ, Kim HJG, Barnhart HX, Jackson EF, Giger ML, Pennello G, Toledano AY, Kalpathy-Cramer J, Apanasovich TV, Kinahan PE, Myers KJ, Goldgof DB, Barboriak DP, Gillies RJ, Schwartz LH, Sullivan DC. Quantitative imaging biomarkers: a review of statistical methods for computer algorithm comparisons. Stat Methods Med Res 2014; 24:68-106. [PMID: 24919829 DOI: 10.1177/0962280214537390] [Citation(s) in RCA: 117] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Quantitative biomarkers from medical images are becoming important tools for clinical diagnosis, staging, monitoring, treatment planning, and development of new therapies. While there is a rich history of the development of quantitative imaging biomarker (QIB) techniques, little attention has been paid to the validation and comparison of the computer algorithms that implement the QIB measurements. In this paper we provide a framework for QIB algorithm comparisons. We first review and compare various study designs, including designs with the true value (e.g. phantoms, digital reference images, and zero-change studies), designs with a reference standard (e.g. studies testing equivalence with a reference standard), and designs without a reference standard (e.g. agreement studies and studies of algorithm precision). The statistical methods for comparing QIB algorithms are then presented for various study types using both aggregate and disaggregate approaches. We propose a series of steps for establishing the performance of a QIB algorithm, identify limitations in the current statistical literature, and suggest future directions for research.
Collapse
|
94
|
Huang EP, Wang XF, Choudhury KR, McShane LM, Gönen M, Ye J, Buckler AJ, Kinahan PE, Reeves AP, Jackson EF, Guimaraes AR, Zahlmann G. Meta-analysis of the technical performance of an imaging procedure: guidelines and statistical methodology. Stat Methods Med Res 2014; 24:141-74. [PMID: 24872353 DOI: 10.1177/0962280214537394] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Medical imaging serves many roles in patient care and the drug approval process, including assessing treatment response and guiding treatment decisions. These roles often involve a quantitative imaging biomarker, an objectively measured characteristic of the underlying anatomic structure or biochemical process derived from medical images. Before a quantitative imaging biomarker is accepted for use in such roles, the imaging procedure to acquire it must undergo evaluation of its technical performance, which entails assessment of performance metrics such as repeatability and reproducibility of the quantitative imaging biomarker. Ideally, this evaluation will involve quantitative summaries of results from multiple studies to overcome limitations due to the typically small sample sizes of technical performance studies and/or to include a broader range of clinical settings and patient populations. This paper is a review of meta-analysis procedures for such an evaluation, including identification of suitable studies, statistical methodology to evaluate and summarize the performance metrics, and complete and transparent reporting of the results. This review addresses challenges typical of meta-analyses of technical performance, particularly small study sizes, which often causes violations of assumptions underlying standard meta-analysis techniques. Alternative approaches to address these difficulties are also presented; simulation studies indicate that they outperform standard techniques when some studies are small. The meta-analysis procedures presented are also applied to actual [18F]-fluorodeoxyglucose positron emission tomography (FDG-PET) test-retest repeatability data for illustrative purposes.
Collapse
|
95
|
Mountz JM, Yankeelov TE, Rubin DL, Buatti JM, Erikson BJ, Fennessy FM, Gillies RJ, Huang W, Jacobs MA, Kinahan PE, Laymon CM, Linden HM, Mankoff DA, Schwartz LH, Shim H, Wahl RL. Letter to cancer center directors: Progress in quantitative imaging as a means to predict and/or measure tumor response in cancer therapy trials. J Clin Oncol 2014; 32:2115-6. [PMID: 24868025 DOI: 10.1200/jco.2014.55.8866] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
96
|
Wang S, Bowen SR, Chaovalitwongse WA, Sandison GA, Grabowski TJ, Kinahan PE. Respiratory trace feature analysis for the prediction of respiratory-gated PET quantification. Phys Med Biol 2014; 59:1027-45. [PMID: 24504153 DOI: 10.1088/0031-9155/59/4/1027] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
The benefits of respiratory gating in quantitative PET/CT vary tremendously between individual patients. Respiratory pattern is among many patient-specific characteristics that are thought to play an important role in gating-induced imaging improvements. However, the quantitative relationship between patient-specific characteristics of respiratory pattern and improvements in quantitative accuracy from respiratory-gated PET/CT has not been well established. If such a relationship could be estimated, then patient-specific respiratory patterns could be used to prospectively select appropriate motion compensation during image acquisition on a per-patient basis. This study was undertaken to develop a novel statistical model that predicts quantitative changes in PET/CT imaging due to respiratory gating. Free-breathing static FDG-PET images without gating and respiratory-gated FDG-PET images were collected from 22 lung and liver cancer patients on a PET/CT scanner. PET imaging quality was quantified with peak standardized uptake value (SUV(peak)) over lesions of interest. Relative differences in SUV(peak) between static and gated PET images were calculated to indicate quantitative imaging changes due to gating. A comprehensive multidimensional extraction of the morphological and statistical characteristics of respiratory patterns was conducted, resulting in 16 features that characterize representative patterns of a single respiratory trace. The six most informative features were subsequently extracted using a stepwise feature selection approach. The multiple-regression model was trained and tested based on a leave-one-subject-out cross-validation. The predicted quantitative improvements in PET imaging achieved an accuracy higher than 90% using a criterion with a dynamic error-tolerance range for SUV(peak) values. The results of this study suggest that our prediction framework could be applied to determine which patients would likely benefit from respiratory motion compensation when clinicians quantitatively assess PET/CT for therapy target definition and response assessment.
Collapse
|
97
|
Harrison RL, Elston BF, Doot RK, Lewellen TK, Mankoff DA, Kinahan PE. A Virtual Clinical Trial of FDG-PET Imaging of Breast Cancer: Effect of Variability on Response Assessment. Transl Oncol 2014; 7:138-46. [PMID: 24772217 PMCID: PMC3998682 DOI: 10.1593/tlo.13847] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2013] [Revised: 03/10/2014] [Accepted: 03/11/2014] [Indexed: 12/13/2022] Open
Abstract
INTRODUCTION There is growing interest in using positron emission tomography (PET) standardized uptake values (SUVs) to assess tumor response to therapy. However, many error sources compromise the ability to detect SUV changes. We explore relationships between these errors and overall SUV variability. METHODS We used simulations in a virtual clinical trial framework to study impacts of error sources from scanning and analysis effects on assessment of SUV changes. We varied tumor diameter, scan duration, pretherapy SUV, magnitude of change in SUV, image reconstruction filter, and SUV metric. Poisson noise was added to the raw data before image reconstruction. Variance from global sources of error, e.g., scanner calibration, was incorporated. Two thousand independent noisy sinograms per scenario were generated and reconstructed. We used SUVs to create receiver operating characteristic (ROC) curves to quantify ability to assess response. Integrating area under the ROC curve summarized ability to detect SUV changes. RESULTS Scan duration and image reconstruction method had relatively little impact on ability to measure response. SUVMAX is nearly as effective as SUVMEAN, especially with increased image smoothing and despite size-matched region of interest placement. For an effective variability of 15%, we found the Positron Emission Tomography Response Criteria in Solid Tumors criteria for measuring response (±30%) similar to the European Organization for Research and Treatment of Cancer criteria (±25%). CONCLUSIONS For typical PET variance levels, tumor response must be 30% to 40% to be reliably determined using SUVs. PET scan duration and image reconstruction method had relatively little effect.
Collapse
|
98
|
Perlmutter DS, Kim SM, Kinahan PE, Alessio AM. Mixed Confidence Estimation for Iterative CT Reconstruction. CONFERENCE PROCEEDINGS. INTERNATIONAL CONFERENCE ON IMAGE FORMATION IN X-RAY COMPUTED TOMOGRAPHY 2014; 2014:29-32. [PMID: 25635266 PMCID: PMC4307401] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
We present a statistical analysis of our previously proposed Constrain-Static Target-Kinetic algorithm for 4D CT reconstruction. This method, where framed iterative reconstruction is only performed on the dynamic regions of each frame, while static regions are fixed across frames to a composite image, was proposed to reduce computation time. In this work, we generalize the previous method to describe any application where a portion of the image is known with higher confidence (static, composite, lower-frequency content, etc.) and a portion of the image is known with lower confidence (dynamic, targeted, etc). We show that by splitting the image space into higher and lower confidence components, CSTK can lower the estimator variance in both regions compared to conventional reconstruction. We present a theoretical argument for this reduction in estimator variance and verify this argument with proof-of-principle simulations. This method allows for reduced computation time and improved image quality for imaging scenarios where portions of the image are known with more certainty than others.
Collapse
|
99
|
Kurland BF, Doot RK, Linden HM, Mankoff DA, Kinahan PE. Multicenter trials using ¹⁸F-fluorodeoxyglucose (FDG) PET to predict chemotherapy response: effects of differential measurement error and bias on power calculations for unselected and enrichment designs. Clin Trials 2013; 10:886-95. [PMID: 24169628 DOI: 10.1177/1740774513506618] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
BACKGROUND Clinical validation of a predictive biomarker is especially difficult when the biomarker cannot be assessed retrospectively. A cost-effective, prospective multicenter replication study with rapid accrual is warranted prior to further validation studies such as a marker-based strategy for treatment selection. However, it is often unknown how measurement error and bias in a multicenter trial will differ from that in single-institution studies. PURPOSE Power calculations using simulated data may inform the efficient design of a multicenter study to replicate single-institution findings. This case study used serial standardized uptake value (SUV) measures from (18)F-fluorodeoxyglucose (FDG) positron emission tomography (PET) to predict early response to breast cancer neoadjuvant chemotherapy. We examined the impact of accelerating accrual through increased inclusion of secondary sites with greater levels of measurement error and bias. We also examined whether enrichment designs based on breast cancer initial uptake could increase the study power for a fixed budget (200 total scans). METHODS Reference FDG PET SUV data were selected with replacement from a single-institution trial; pathologic complete response (pCR) data were simulated using a logistic regression model predicting response by mid-therapy percent change in SUV. The impact of increased error for SUV measurements in multicenter trials was simulated by sampling from error and bias distributions: 20%-40% measurement error, 0%-40% bias, and fixed error/bias values. The proportion of patients recruited from secondary sites (with higher additional error/bias compared to primary sites) varied from 25% to 75%. RESULTS Reference power (from source data with no added error) was 0.92 for N = 100 to detect an association between percentage change in SUV and response. With moderate (20%) simulated measurement error for 3/4, 1/2, and 1/4 of measurements and 40% for the remainder, power was 0.70, 0.61, and 0.53, respectively. Reduction of study power was similar for other manifestations of measurement error (bias as a percentage of true value, absolute error, and absolute bias). Enrichment designs, which recruit additional patients by not conducting a second scan in patients with unsuitable pre-therapy uptake (low baseline SUV), did not lead to greater power for studies constrained to the same total cost. LIMITATIONS Simulation parameters could be incorrect, or not generalizable. Under a different logistic regression model relating mid-therapy percent change in SUV to pCR (with no relationship for patients with low baseline SUV, rather than the modest point estimate from reference data), the enrichment design did have somewhat greater power than the unselected design. CONCLUSION Even moderate additional measurement error substantially reduced study power under both unselected and enrichment designs.
Collapse
|
100
|
Kim SM, Alessio AM, De Man B, Asma E, Kinahan PE. Direct Reconstruction of CT-based Attenuation Correction Images for PET with Cluster-Based Penalties. IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD. NUCLEAR SCIENCE SYMPOSIUM 2013; 2013. [PMID: 26185410 DOI: 10.1109/nssmic.2013.6829245] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Extremely low-dose CT acquisitions for the purpose of PET attenuation correction will have a high level of noise and biasing artifacts due to factors such as photon starvation. This work explores a priori knowledge appropriate for CT iterative image reconstruction for PET attenuation correction. We investigate the maximum a posteriori (MAP) framework with cluster-based, multinomial priors for the direct reconstruction of the PET attenuation map. The objective function for direct iterative attenuation map reconstruction was modeled as a Poisson log-likelihood with prior terms consisting of quadratic (Q) and mixture (M) distributions. The attenuation map is assumed to have values in 4 clusters: air+background, lung, soft tissue, and bone. Under this assumption, the MP was a mixture probability density function consisting of one exponential and three Gaussian distributions. The relative proportion of each cluster was jointly estimated during each voxel update of direct iterative coordinate decent (dICD) method. Noise-free data were generated from NCAT phantom and Poisson noise was added. Reconstruction with FBP (ramp filter) was performed on the noise-free (ground truth) and noisy data. For the noisy data, dICD reconstruction was performed with the combination of different prior strength parameters (β and γ) of Q- and M-penalties. The combined quadratic and mixture penalties reduces the RMSE by 18.7% compared to post-smoothed iterative reconstruction and only 0.7% compared to quadratic alone. For direct PET attenuation map reconstruction from ultra-low dose CT acquisitions, the combination of quadratic and mixture priors offers regularization of both variance and bias and is a potential method to derive attenuation maps with negligible patient dose. However, the small improvement in quantitative accuracy relative to the substantial increase in algorithm complexity does not currently justify the use of mixture-based PET attenuation priors for reconstruction of CT images for PET attenuation correction.
Collapse
|