101
|
Huynh C, Liu I, Sommer A, Menke L, Reilly L, Gasper W, Hiramoto J. Descending thoracic aortic mural ulceration is associated with postoperative spinal cord ischemia after branched endovascular aortic aneurysm repair. J Vasc Surg 2024; 79:732-739. [PMID: 38036115 DOI: 10.1016/j.jvs.2023.11.034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 11/17/2023] [Accepted: 11/21/2023] [Indexed: 12/02/2023]
Abstract
OBJECTIVE Paraplegia is one of the most feared complications after thoracoabdominal aortic aneurysm repair. The purpose of this study is to determine whether aortic thrombus characteristics are associated with spinal cord ischemia (SCI) after branched endovascular aneurysm repair (BEVAR). METHODS From April 2011 to April 2020, 62 patients underwent elective BEVAR for thoracoabdominal aortic aneurysm and pararenal aortic aneurysms using a low-profile device and had a complete preoperative computed tomography angiography of the aorta from the sinotubular junction to the aortic bifurcation. Aortic thrombus was evaluated for thrombus thickness ≥5 mm, thrombus >2/3 of aortic circumference, and the presence of an ulcer-like thrombus. One point was assigned at each 5 mm axial image if all 3 criteria were met, resulting in a total "shaggy score" for the entire aorta. Data on demographics, procedural details, and outcomes were collected prospectively. All patients underwent a standard spinal cord protection protocol, including routine cerebrospinal fluid drainage. In July 2016, an insulin infusion protocol (IIP) was initiated to maintain postoperative blood glucose levels <120 mg/dL for 48 hours. The primary clinical end point was postoperative SCI. RESULTS 10 (16%) patients developed postoperative SCI: 6 with transient paraparesis, 2 with persistent paraparesis, and 2 with persistent paraplegia. Patients with SCI were older, had higher shaggy scores, and were less likely to have been on an IIP. There were no significant differences in demographics, aneurysm type, or operative parameters. In a logistic multivariate regression model for SCI, age (odds ratio [OR]: 1.2 [1.1-1.4], P = .02) and shaggy score (OR: 1.2 [1.1-1.4], P = .02) were independently associated with increased risk of SCI, whereas treatment with the IIP was associated with lower risk of SCI (OR: 0.04 [0.006-0.50], P = .05). Of the individual components of the shaggy score, higher descending thoracic aortic ulcer scores were the most strongly associated with postoperative SCI (P = .009). CONCLUSIONS Preoperative characterization of aortic wall thrombus is an important adjunctive tool for individualized clinical decision-making and patient counseling about the risk of SCI after BEVAR.
Collapse
|
102
|
Cicala N, Perini P, Catasta A, Fornasari A, Ucci A, Freyrie A. Systematic review and meta-analysis of incidence, indications, and outcomes of early open conversions after EVAR for abdominal aortic aneurysms. INT ANGIOL 2024; 43:271-279. [PMID: 38502543 DOI: 10.23736/s0392-9590.24.05153-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/21/2024]
Abstract
INTRODUCTION The purpose of this study is to report incidence, indications, and outcomes of early open conversions (EOC) after endovascular aortic repair (EVAR), defined as surgical conversion performed within 30 days from the initial EVAR. EVIDENCE AQUISITION A systematic review of the literature was performed (database searched: PubMed, Web of Science, Scopus, Cochrane Library; last search April 2023). Articles reporting EOC after EVAR comprising at least five patients were included. Meta-analyses of proportions were performed using a random-effects model. EVIDENCE SYNTHESIS Seventeen non-randomized studies, published between 1999 and 2022, were included. A total of 35,970 patients had previously undergone EVAR, of these 438 patients underwent EOC. Estimated incidence of EOC was 1.4% (95% CI 1.1-1.4; I2=81.66%). Specifically, in the works published before 2010 the incidence was 1.8% (95% CI 1.3-2.4; I2=74.25) while for subsequent ones it was 0.9% (95% CI 0.6-1.1; I2=69.82). Weighted mean age was 74.91 years (95% CI 72.42-77.39; I2=83.11%). Estimated rate of cause determining EOC were: access issue in 27.7% of patients (95% CI 13.8-41.6; I2=88.14%), incorrect placement of the endograft in 20.1% (95% CI 10.2-30.0; I2=76,9%), problems with "delivery system" in 9.0% (95% CI 4.9-13.1; I2=0%), aorto-iliac rupture in 8.6% (95% CI 4.5-12.6; I2=0%), endoprosthesis migration in 7.9% of cases (95% CI 3.3-12.4; I2=22.96%), failure in engaging the contralateral gate in 4.8% (95% CI 1.6-8; I2=0%), "kinking" or "twisting" of endoprosthesis in 3.3% (95% CI 0.6-5.9; I2=0%), graft thrombosis in 3.2% (95% CI 0.6-5.7; I2=0%), type Ia endoleak in 2.9% (95% CI 0.4-5.4; I2=0%), type III endoleak in 2.8% (95% CI 0.3-5.3; I2=0%) and endograft infection in 2.7% (95% CI 0.3-5.2; I2=0%). Intraoperative conversion rate was 91.1% (95% CI 85.8-96.4; I2=66.01%). Early mortality rate after EOC was 14.5% (95% CI 9.1-19.9; I2=48.31%). Mean length of stay (LOS) was 11.94 days (95% CI 6.718-17.172; I2=92.34%). CONCLUSIONS The incidence of EOC seems to decrease over time. Causes of EOC were mainly related to access problems and incorrect positioning of the endograft. Most of the EOC were performed intraoperatively carrying a high mortality rate.
Collapse
|
103
|
Kritayakirana K, Narueponjirakul N, Aimsupanimitr P, Chaichote C, Uthaipaisanwong A, Kittayarak C. Open versus endovascular repair of primary infected thoracic and abdominal aortic aneurysms. Vascular 2024; 32:262-266. [PMID: 36395473 DOI: 10.1177/17085381221140173] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2024]
Abstract
OBJECTIVE Primary infected aortic aneurysms are life-threatening if not treated promptly, but still possess a high mortality rate following open repair. The goal of treatment is to prevent rupture and clear infection. An endovascular approach is accepted as a bridge to definitive open repair. Our study compares the outcomes of endovascular versus conventional open repair of infected aortic aneurysms. METHOD A single-center retrospective review was conducted of data from January 2012 to December 2021. Patients were categorized into three cohorts according to aortic involvement: thoracic aortic aneurysm (TAA), thoracoabdominal aortic aneurysm (TAAA), and abdominal aortic aneurysm (AAA). The primary endpoint was survival rate and the assessment of any associated factors. RESULT Ninety-nine patients presented with infected aortic aneurysms. Of the 56 patients who presented with infected TAA, 38 patients underwent thoracic endovascular aortic repair and 18 patients underwent open TAA repair. Forty patients presented with infected AAA, of which 21 patients underwent endovascular aortic repair and 19 patients underwent open repair. Three patients presented with infected TAAA and all underwent open repair. The mean age was 67 years (range 33-88); 74 patients (74.8%) were men and 71 patients (71.7%) had immune dysfunction. Mean follow-up time was 24 months in the endovascular repair group and 38 months in the open repair group. The probability survival rate in the endovascular repair group was 86%, 86%, 77% and 51% at 1 year, 2 years, 5 years and 10 years, respectively, and in the open repair group this was 81%, 81%, 76%, and 64% at 1 year, 2 years, 5 years and 10 years, respectively. CONCLUTIONS Endovascular repair for primary infected aortic aneurysms plays an important role in current practice as an alternate to open surgery or used as bridging to definitive open surgical repair. No significant difference was observed in either short- or long-term survival in patients with infected aortic aneurysm undergoing open or endovascular repairs.
Collapse
MESH Headings
- Humans
- Endovascular Procedures/adverse effects
- Endovascular Procedures/mortality
- Male
- Retrospective Studies
- Female
- Aged
- Aortic Aneurysm, Abdominal/surgery
- Aortic Aneurysm, Abdominal/mortality
- Aortic Aneurysm, Abdominal/diagnostic imaging
- Blood Vessel Prosthesis Implantation/adverse effects
- Blood Vessel Prosthesis Implantation/mortality
- Blood Vessel Prosthesis Implantation/instrumentation
- Middle Aged
- Aortic Aneurysm, Thoracic/surgery
- Aortic Aneurysm, Thoracic/diagnostic imaging
- Aortic Aneurysm, Thoracic/mortality
- Treatment Outcome
- Aged, 80 and over
- Time Factors
- Aneurysm, Infected/surgery
- Aneurysm, Infected/mortality
- Aneurysm, Infected/microbiology
- Aneurysm, Infected/diagnostic imaging
- Risk Factors
- Adult
- Postoperative Complications/mortality
- Postoperative Complications/etiology
- Risk Assessment
Collapse
|
104
|
Shirasu T, Akai A, Motoki M, Kato M. Midterm outcomes of side branch embolization and endovascular abdominal aortic aneurysm repair. J Vasc Surg 2024; 79:784-792.e2. [PMID: 38070786 DOI: 10.1016/j.jvs.2023.12.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2023] [Revised: 11/29/2023] [Accepted: 12/03/2023] [Indexed: 01/06/2024]
Abstract
OBJECTIVE To analyze the effects of total side branch embolization at endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms on the incidences of persistent type 2 endoleak (pT2EL), changes in sac diameter, and reintervention. METHODS Between 2013 and 2021, all patients who underwent primary EVAR with a few exceptions were included. Side branch embolization was considered during EVAR for inferior mesenteric artery (IMA) or IMA plus lumbar artery (LA) when feasible for contrast agent use. Outcomes measured were pT2EL, sac diameters, reintervention, ruptures, and aneurysm-related mortality. Radiation exposure and safety outcomes were also reported. RESULTS Among 732 patients who underwent EVAR, 616 (84.2%) were included. Of the 616 patients, 223 (36.2%) did not undergo side branch embolization (NO-E), whereas 228 (37.0%) underwent IMA only (IMA-E) and 165 (26.8%) underwent IMA+LA including median sacral artery (IMA+LA-E). The technical success rate of IMA and LA embolization was 97.0% and 74.7%, respectively. Crude incidences of pT2EL were significantly different from 6 months through 3 years (NO-E, 27.8%; IMA-E, 31.7%; IMA+LA-E, 9.4% at 3 years; P = .007). In the multivariate analysis adjusted for background differences, the incidences of pT2EL were significantly higher in the NO-E (odds ratio [OR], 3.21; 95% confidence intervals [CIs], 1.08-9.57; P = .004) and IMA-E (OR, 4.86; 95% CIs, 1.68-14.11; P = .004) compared with the IMA+LA-E group. Similarly, any reintervention until 3 years was significantly frequent in the NO-E (OR, 5.26; 95% CIs, 1.76-15.70; P = .003) and IMA-E group (OR, 4.19; 95% CIs, 1.38-12.67; P = .01). Surgical conversion and secondary rupture were seen only in 1 patient without any aneurysm-related mortality. Percent sac shrinkage from the baseline was significantly promoted in the IMA+LA group (NO-E, 12.1% ± 16.6%; IMA-E, 11.4% ± 16.7%; IMA+LA-E, 18.0% ± 18.8%; P = .047). Fluoroscopy time was significantly longer in the IMA+LA-E group (NO-E, 60.2 ± 47.4 minutes; IMA-E, 59.3 ± 39.5 minutes; IMA+LA-E, 75.5 ± 42.8 minutes; P < .0001), and so do the dose-area product (NO-E, 424.6 ± 333.4 Gy cm2; IMA-E, 477.7 ± 342.4 Gy cm2; IMA+LA-E, 631.8 ± 449.1 Gy cm2; P < .0001). No embolization-related complications or radiation-related adverse events were recorded. CONCLUSIONS Pre-emptive embolization of IMA, LAs, and median sacral artery at the time of EVAR reduced the incidences of pT2EL and any reintervention and promoted sac shrinkage during the follow-up period of 3 years.
Collapse
|
105
|
Ribé L, Candela E, Gálvez L, Arrébola M, Plana E, Miralles M. Comparison of Three Workstations For Abdominal Aortic Aneurysm Sizing: Impact in Decision Making and Graft Selection. J Endovasc Ther 2024; 31:295-304. [PMID: 36124870 DOI: 10.1177/15266028221120767] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
PURPOSE The aim of this study was to assess the agreement of multiplanar reconstruction (MPR) and semiautomated central lumen line (CLL) analysis of abdominal aortic aneurysms (AAA), with 3 different software workstations (WS1, WS2, WS3) and 2 experienced practitioners as well as to analyze its eventual impact in graft selection. MATERIALS AND METHODS Twenty computed tomography (CT) angiography data sets were randomly chosen from a series of 100 consecutive studies. Measurements were performed twice by each reader, in random order, and included 8 parameters (5 diameters and 3 lengths). Each observer performed a complete set of 60 studies. Intra-observer and interobserver variability for every WS was assessed. Measurements were evaluated using Bland-Altman analysis, correlation coefficients (r), and concordance correlation coefficients (CCC [95% confidence interval (CI)]). RESULTS A high overall agreement between repeated measurements for both observers was obtained (r=0.989; CCC=0.988 [0.982-0.992] and r=0.998; CCC=0.996 [0.994-0.997], for observers 1 and 2, respectively). However, reproducibility for individual parameters was excellent for observer 2 and only moderate for observer 1. A high overall agreement was obtained for interobserver concordance (r=0.987; CCC=0.986 [0.982-0.989]). When analyzing for individual parameters, greatest interobserver differences were found at CLL measurement of the diameter of aortic neck (WS2) and bifurcation (WS1 and WS2) as well as iliac diameter in all 3 WS for both CLL and MPR. Similar differences were observed in paired comparison between WS when involving these parameters. Careful inspection of Bland-Altman charts revealed some cases of disagreement between WS and observers that would affect decision making on graft selection, changing the neck diameter to a different size, in 2 cases when measuring with WS1, and iliac diameter in 4 cases (2 of them with WS1 and 2 with WS2). Greatest discordance was observed regarding ipsilateral iliac length affecting 7 measurements that would lead to change the length of the selected limb graft (2 with WS1, 3 with WS2, and 2 with WS3). CONCLUSIONS Although a high agreement between different observers using different WS for AAA measurements is to be expected, small differences may lead to the selection of a different graft size. The use of a single software by experienced users, and double check by a different one, may be advisable. CLINICAL IMPACT Influence of inter and intraobserver variability in CT measurements during planning of endovascular aneurysm repair (EVAR) has been extensively reviewed. However, its impact in graft selection (final choose of diameter and lengths) has been scarcely analyzed. The results of this study suggest that, although a high agreement between different observers using different workstations for AAA measurements is to be expected, small differences may lead to the selection of a different graft size. The use of a single software by experienced users, and double check by a different one, may be advisable.
Collapse
|
106
|
Mesnard T, Pruvot L, Oliver Patterson B, Préville AD, Azzaoui R, Sobocinski J. Early Institutional Experience with One-Piece Bifurcated-Fenestrated Stentgraft in the Treatment of Abdominal Aortic Aneurysms. J Endovasc Ther 2024; 31:241-247. [PMID: 36112831 DOI: 10.1177/15266028221119612] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/18/2024]
Abstract
PURPOSE To review the early experience of the use of a bifurcated-fenestrated endograft (Bif-FEVAR) to treat abdominal aortic aneurysms (AAA) in a high-volume aortic center. METHODS A retrospective single-center analysis was conducted between March 2019 and April 2021 including consecutive patients that underwent Bif-FEVAR. Only patients without a proper infrarenal neck and a distance <70 mm between the lowest target artery and the native or prosthetic aortic bifurcation were considered. All Bif-FEVAR custom-made devices were manufactured by Cook Medical (Inc., Bloomington, Indiana). Demographics, anatomical features, technical success, major adverse events, 30-day mortality, and survival according to Kaplan-Meier were analyzed according to Society for Vascular Surgery standards. RESULTS Overall, 10 patients (100% male with median age 78) were included. The median preoperative maximal aneurysm diameter was 68 mm [51-84]. Eight patients were treated for a proximal type I endoleak after endovascular aneurysm repair. A total of 36 fenestrations were planned. The median operative time was 144 min [127-168], with a median fluoro time of 40.5 min [34-54] and a median dose area product of 73 Gy cm2 [61-89]. Technical success rate was 100%. No patients experienced a major postoperative adverse event. Median follow-up time was 8 months [6-13]. CONCLUSION Bif-FEVAR is technically feasible when there is a short distance below the lowest target artery and the aortic bifurcation, with favorable short-term results. CLINICAL IMPACT This study assessed the use of an innovative one-piece bifurcated fenestrated stent-graft as a primary procedure or in the treatment of proximal endoleak after standard infrarenal EVAR. We demonstrated these custom-made devices can be used safely with favorable short-term results. One-piece bifurcated fenestrated stent-grafts extend the indications of FEVAR for patients with an unusually short distance between the lowest renal artery and the aorto-iliac bifurcation or the diverter flow of a preexisting bifurcated infrarenal stent-graft.
Collapse
|
107
|
Gouveia E Melo R, Mendes Pedro L. Fiber Optic RealShape in Endovascular Aneurysm Repair: Following the Light into a Future with Less Radiation Exposure. Eur J Vasc Endovasc Surg 2024; 67:601-602. [PMID: 38056522 DOI: 10.1016/j.ejvs.2023.12.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2023] [Accepted: 12/01/2023] [Indexed: 12/08/2023]
|
108
|
Shalhoub J. Can We - And Should We - Offer Certification for Basic Skills in Endovascular Aneurysm Repair? Eur J Vasc Endovasc Surg 2024; 67:681. [PMID: 38040107 DOI: 10.1016/j.ejvs.2023.11.041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2023] [Accepted: 11/23/2023] [Indexed: 12/03/2023]
|
109
|
Taneva GT, Pitoulias AG, Avranas K, Donas KP. Latest evidence on chimney endovascular repair of abdominal aortic aneurysms and the renal artery angulation pitfall. THE JOURNAL OF CARDIOVASCULAR SURGERY 2024; 65:119-123. [PMID: 38618696 DOI: 10.23736/s0021-9509.24.12936-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/16/2024]
Abstract
This article summarizes the key findings in literature up to date on the endovascular treatment of complex abdominal aortic aneurysms (AAAs) employing the chimney technique. Additionally, an unexplored pitfall is described regarding the target vessel angulation. Although balloon-expandable covered stents present more favorable configuration in downward-oriented target vessels, transverse and upward-oriented target vessels may benefit from other endovascular techniques imploring careful case planning and further investigation on the topic.
Collapse
|
110
|
Gormley S, Mao J, Sedrakyan A, Beck AW, Mani K, Beiles B, Szeberin Z, Venermo M, Cassar K, Khashram M. The association of ruptured abdominal aortic aneurysm diameter with mortality in the International Consortium of Vascular Registries. J Vasc Surg 2024; 79:748-754.e2. [PMID: 38013041 PMCID: PMC11144387 DOI: 10.1016/j.jvs.2023.11.033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Revised: 11/15/2023] [Accepted: 11/21/2023] [Indexed: 11/29/2023]
Abstract
BACKGROUND The mortality after ruptured abdominal aortic aneurysm (rAAA) repair is high, despite improvements in perioperative care, centralization of emergency vascular surgical services, and the introduction of endovascular aneurysm repair (EVAR). The diameter of intact AAA has been shown to be a predictor of short- and long-term survival. The aim of this study was to analyze the impact of AAA diameter on mortality for rAAA repair using contemporary data collected from the International Consortium of Vascular Registries and compare outcomes by sex and the type of repair patients received. METHODS Prospective registry data on repair of rAAA from seven countries were collected from 2010 to 2016. The primary outcome was perioperative mortality after EVAR and open surgical repair (OSR). Data were stratified by type of repair and sex. Logistic regression models were used to estimate odds ratio (OR) for the association between AAA diameter and perioperative mortality and the association between type of repair and mortality. Multivariable logistic regression models were used to adjust for differences in patient characteristics. RESULTS The study population consisted of 6428 patients with a mean age ranging from 70.2 to 75.4 years; the mean AAA diameter was 7.7 ± 1.8 cm. Females had a significantly smaller AAA diameter at presentation compared with males (6.9 ± 1.6 cm vs 7.9 ± 1.8 cm; P < .001). who underwent OSR had larger AAA diameters compared with those who underwent EVAR (P < .001). Females who underwent repair were significantly older (P < .001). Males were more likely to have cardiac disease, diabetes mellitus, and renal impairment. Overall, AAA diameter was a predictor of mortality in univariate and multivariate analysis. When analyzing EVAR and OSR separately, the impact of AAA diameter per cm increase on mortality was apparent in both males and females undergoing EVAR, but not OSR (EVAR: male OR, 1.09 [95% confidence interval, 1.03-1.16] and EVAR: female OR, 1.17 [95% confidence interval, 1.02-1.35]). The early mortality rate for males and females who underwent EVAR was 18.9% and 25.9% (P < .001), respectively. The corresponding mortality for males and females who underwent OSR was 30.2% and 38.6% (P < .001), respectively. CONCLUSIONS In these real-world international data, there is a significant association between rAAA diameters and early mortality in males and females. This association was more evident in patients undergoing EVAR, but not shown in OSR. Despite improvements in overall AAA repair outcomes, the risk of mortality after rAAA repair is consistently higher for females.
Collapse
|
111
|
Esposito D, Onida S, Turner B, Rawashdeh M, Jenkins MP, Pulli R, Davies AH. Systematic review and meta-analysis of outcomes after semi-conversion with graft preservation for failed endovascular aneurysm repair. J Vasc Surg 2024; 79:973-981.e4. [PMID: 37619915 DOI: 10.1016/j.jvs.2023.08.113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Revised: 07/24/2023] [Accepted: 08/15/2023] [Indexed: 08/26/2023]
Abstract
OBJECTIVE The aim of this study was to evaluate the outcomes after semi-conversion (open conversion with graft preservation) after failed endovascular aneurysm repair (EVAR). The primary outcomes were 30-day mortality and semi-conversion failure. Secondary outcomes were 30-day major systemic complications, endoleak recurrence, reinterventions, and overall survival. METHODS The review followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. The protocol was prospectively registered on PROSPERO (CRD42023421153). All studies reporting the outcomes of semi-conversions for failed EVAR were eligible for inclusion. Quality assessment was performed using the Methodological Index for Non-Randomized Studies (MINORS) tool. A random effects meta-regression of proportions was conducted using the double arcsine-Tukey transformation, given the frequent zero event rate in the primary outcome. Heterogeneity was assessed with the I2 statistic. RESULTS Eight studies were included in the review after full text screening. A total of 196 patients underwent semi-conversion at a mean time from EVAR of 47.4 months, 68.9% in an elective setting. Mean age at conversion was 78.1 years, and the main indication was isolated endoleak type II (70.1% of cases). Aortic clamping was not necessary in 92.3% of semi-conversions; the aortic sac was opened in 96.1% of cases; in 93.3% of cases, ligation/suture of one or more culprit arteries were performed; and aortic neck banding was executed in 29.2%. At 30 days from surgery, the pooled mortality and the major systemic complications rates were 5.3% (I2 = 24.9%) and 13.4% (I2 = 54.3%), respectively. At follow-up, endoleak recurred after 12.6% semi-conversions (I2 = 83.2%), and the rate of reinterventions was 7% (I2 = 50.1%); the semi-conversion failure rate was 5.5% (I2 = 54.1%), and the overall survival was 84.6% (I2 = 33.3%). CONCLUSIONS Semi-conversions have acceptable 30-day mortality rates, but the early and mid-term risks of complications, reinterventions, ruptures, and infections are not negligible. This procedure might be an alternative to complete or partial graft explant in patients whom aortic cross-clamping is not ideal.
Collapse
|
112
|
Andoniadis M, Gravenstein N. Perioperative care in open aortic vascular surgery: Comment. J Vasc Surg 2024; 79:985-986. [PMID: 38519220 DOI: 10.1016/j.jvs.2023.11.064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Accepted: 11/13/2023] [Indexed: 03/24/2024]
|
113
|
Saricilar EC, Dinh K, Chui JN, Banzic I, Puttaswamy V. Is There a Role for Heli-FX Endoanchors in Treating Type 1B Common Iliac Artery Endoleaks? Vasc Endovascular Surg 2024; 58:255-262. [PMID: 37837310 DOI: 10.1177/15385744231207019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/15/2023]
Abstract
OBJECTIVES The management of type 1B endoleaks following endovascular aortic aneurysm repair (EVAR) can be challenging. The Heli-FX Endoanchor system effectively treats proximal type 1A endoleaks but has not been used for type 1B common iliac artery endoleaks. This study demonstrates that it is both safe and effective in being used in the common iliac artery (CIA) limb of an EVAR. METHODS A retrospective review of patients identified through coding and medical records was performed to extract information on demographics, aneurysmal features, operative features, and postoperative outcomes. This was then collated and analysed thoroughly and compared to existing research. RESULTS Four patients with six type 1B CIA endoleaks were treated with Heli-FX Endoanchors in the CIA limbs of EVAR grafts. There was 100% technical success rate with complete exclusion of the endoleaks at 6 months. With mean follow up of 714 days, there were no Endoanchor-specific complications. One patient required explantation of the aortic endograft due to contralateral limb fracture, where it was found that an Endoanchor had penetrated the common iliac vein, requiring primary closure. CONCLUSIONS Heli-FX Endoanchors were effective within this cohort of patients, though key risks were identified. Adjacent anatomy to the CIA must be considered, which also have nearly half the arterial thickness compared to the aorta. Pre-operative planning is essential given the theoretical risk of placing Endoanchors.
Collapse
|
114
|
Tatsuishi W, Shibuya K, Konishi Y, Konno N, Oi A, Tamura K, Kato Y, Abe T. Impact of Accessory Renal Artery Embolization on Renal Deterioration Under Endovascular Aortic Repair. Vasc Endovascular Surg 2024; 58:308-315. [PMID: 37919942 DOI: 10.1177/15385744231213551] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2023]
Abstract
OBJECTIVE The optimal management strategy for patients with accessory renal arteries undergoing endovascular aortic repair is unclear. This study aimed to investigate the impact of accessory renal artery (aRA) embolization on postoperative renal deterioration and to identify the predictors of postoperative renal deterioration in patients who underwent endovascular aortic repair (EVAR). METHODS A retrospective single-centre observational study was conducted at our hospital. Of 331 consecutive patients who underwent endovascular aortic repair between April 2011 and February 2021, 29 patients with an aRA were included in this study. Spearman's rank correlation coefficients of decrease in estimated glomerular filtration rate (eGFR), renal volume reduction rate, infarcted renal volume, and quantity of contrast use for postoperative renal deterioration were analyzed. The correlation coefficients of the correlations between infarcted renal volume, renal volume reduction rate, and decrease in eGFR and the rate of aRA diameter were also analyzed. Multivariable nominal logistic regression analyses were conducted to evaluate the odds of postoperative renal deterioration. RESULTS The renal volume reduction rate and infarcted renal volume had a significant positive correlation with the decrease in eGFR. Body surface area and preoperative renal volume were significantly but negatively correlated with the decrease in eGFR. The infarcted renal volume, renal volume reduction rate, and decrease in eGFR were significantly and positively correlated with the aRA diameter. The odds ratio for decreased eGFR rate in preoperative renal volume was .96 (95% CI 0.930‒.996, P = .009). CONCLUSIONS EVAR with aRA embolization impacts postoperative renal deterioration in patients with preoperative low renal volume, and the diameter of the embolized aRA might be a predictor of postoperative renal deterioration.
Collapse
|
115
|
Geraedts AC, Zuidema R, Schuurmann RC, Kwant AN, Mulay S, Balm R, de Vries JPP. Shortest Apposition Length at the First Postoperative Computed Tomography Angiography Identifies Patients at Risk for Developing a Late Type Ia Endoleak After Endovascular Aneurysm Repair. J Endovasc Ther 2024; 31:274-281. [PMID: 36113063 PMCID: PMC10938489 DOI: 10.1177/15266028221120514] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/18/2024]
Abstract
PURPOSE Imaging surveillance following endovascular aneurysm repair (EVAR) is strictly recommended. This study investigates the value of endograft apposition and position relative to the aortic neck on the first postoperative computed tomography angiography (CTA) in determining patients at risk for a late type Ia endoleak (T1aEL). MATERIALS AND METHODS Patients with a T1aEL after the first postoperative CTA were selected from a consecutive database and matched with uncomplicated controls. Endograft apposition and position, including the shortest apposition length (SAL), were determined on the first postoperative CTA. The SAL is the shortest distance between the proximal endograft fabric and the first slice where circumferential apposition with the aortic wall is lost. Differences in endograft apposition at the first postoperative CTA were compared between groups. Logistic regression analysis identified independent predictors for late T1aEL. RESULTS A total of 32 patients with a late T1aEL were included and matched with 32 uncomplicated controls. Median follow-up after primary EVAR was 62.0 (interquartile range [IQR]: 36.8, 83.5) months in the T1aEL group compared with 47.5 (IQR: 34.0, 79.3) months in the control group; p=0.265. Median preoperative neck diameter was significantly larger in the T1aEL group than in the control group (26.6 [IQR: 24.9, 29.6] mm versus 23.4 [IQR: 22.5, 25.3] mm); p<0.001. Patients in the T1aEL group had a median SAL of 11.6 (IQR: 4.3, 20.5) mm compared with 20.7 (IQR: 13.1, 24.9) mm in the control group; p=0.002. SAL <10mm on the first postoperative CTA (odds ratio [OR]: 9.63, 95% confidence interval [CI]: 1.60-57.99) and larger neck diameter (OR: 1.80, 95% CI: 1.26-2.57) were independent predictors for developing a late T1aEL. CONCLUSION Preoperative neck diameter and SAL on the first postoperative CTA following EVAR are important predictors for the development of a late T1aEL. Patients with a SAL of <10mm had a significantly higher risk of developing a late T1aEL. Future research should determine whether these patients would benefit from reintervention before an actual T1aEL is present. CLINICAL IMPACT Understanding the mechanisms of endovascular aneurysm repair failure is essential to further enhance clinical outcomes. Adequate proximal sealing is necessary to foster freedom from type 1a endoleak. This study demonstrates that the shortest apposition length (SAL) at the first postoperative computed tomography angiography (CTA) is able to identify patients at risk for a late type 1a endoleak. Especially patients with a SAL <10mm are at high risk. Currently, the guidelines advice repeated imaging with CTA in patients with a seal <10mm. Future research should determine whether these patients would benefit from re-intervention before an actual type 1a endoleak is present.
Collapse
|
116
|
Pecoraro F, Volpe P, Boccalon L, Migliara B, Rivolta N, Silvestro A, Trabattoni PLM, Massara M, Diaco DA, Dinoto E, Urso F, Alberti A, Feriani G, Franchin M, Ravini ML, Saccu C. Outcome Analysis From a Multicenter Registry on Unibody Stent-Graft System for the Treatment of Spontaneous Infrarenal Acute Aortic Syndrome (MURUSSIAS Registry). J Endovasc Ther 2024; 31:232-240. [PMID: 36000341 DOI: 10.1177/15266028221118507] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE This study reports the outcomes from a Multicenter Registry on unibody stent-graft system for the treatment of spontaneous infrarenal acute aortic syndrome (MURUSSIAS registry). MATERIALS AND METHODS The retrospective MURUSSIAS registry included spontaneous infrarenal acute aortic dissection (IAAS) managed with the unibody stent-graft system (AFX endovascular AAA system; Endologix Inc., Irvine, California) outside the current instruction for use. IAAS considered aortic dissection (AD), intramural hematoma (IMH), and penetrating aortic ulcer (PAU). Indications to IAAS treatment were symptoms, associated dilated abdominal aorta (>3 cm), rapidly-growing (>0.5 cm/6 months) aorta, IAAS disease progression. Measured results were technical success, early (within 30 days) and midterm outcomes (after 30 days), including mortality, complications, symptoms recurrence, type I/III endoleak occurrence, stent-graft patency, survival, and freedom from reintervention. The mean follow-up was 22.12 ± 17 months. RESULTS The MURUSSIAS registry included 83 patients from 7 participating centers. IAAS indication to treatment were symptoms in 42 (51%). In 14 (17%) patients, the infrarenal aortic length was <80 mm, and in 28 (34%), the aortic bifurcation diameter was <16 mm. Technical success was 100%. Mortality occurred early in 1 (1%) and at the midterm in 3 (4%) patients. Complications occurred early in 10 (12%) patients (1 severe, 3 moderates, and 6 mild) and at midterm in 2 (2%) (2 moderate). No symptoms' recurrence or type I/III endoleaks were registered. The 36-month estimated survival and freedom from reinterventions were 89% and 92%, respectively. CONCLUSIONS The MURUSSIAS registry is the largest collection of spontaneous IAAS managed endovascularly using the AFX endovascular AAA system. The IAAS peculiar anatomic features were fitted with the used technique with excellent results. This treatment strategy might be considered in IAAS unless specifically-designed endovascular solutions will be available also in the emergent setting. Further studies are required to assess the longer-term performances and the stability of the reported technique. CLINICAL IMPACT The lack of specifically designed devices for infrarenal acute aortic syndrome (IAAS) disease remains an issue principally for its specific anatomic features. The MURUSSIAS registry retrospectively examined the outcomes of spontaneous IAAS treated using the unibody stent-graft system in a spontaneous national study; and reports the largest available data on this topic. The use of the unibody stent-graft system showed to fit the anatomic peculiarities of IAAS with excellent outcomes. This IAAS treatment strategy should be considered unless specifically designed endovascular solutions will be available.
Collapse
|
117
|
Kyrou IE, Antonopoulos CN, Antoniou GA. Time Dependent Correlation Between Sac Behaviour and Re-intervention after Endovascular Aneurysm Repair. Eur J Vasc Endovasc Surg 2024; 67:612-619. [PMID: 37992984 DOI: 10.1016/j.ejvs.2023.11.034] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2023] [Revised: 10/14/2023] [Accepted: 11/16/2023] [Indexed: 11/24/2023]
Abstract
OBJECTIVE This study aimed to investigate the correlation between aneurysm sac behaviour and time to re-intervention after endovascular aneurysm repair (EVAR). METHODS A retrospective observational cohort study of patients who underwent EVAR at a single centre between January 2008 and November 2011 and who were followed up for a mean of 6.6 ± 2.9 years was conducted. Based on sac appearances on pre-operative imaging and imaging at the end of follow up, patients were stratified into two groups: (1) sac regression; and (2) no sac regression. The no sac regression group was further subdivided into stable sac group and sac expansion group. Sac regression and expansion throughout follow up were defined as a decrease or increase in the abdominal aortic aneurysm sac diameter of ≥ 5 mm compared with the pre-operative size. A Cox proportional hazards model using multiple failure per subject data was used to identify sac behaviour as a predictor of re-intervention free time. RESULTS Patients with sac regression had a higher probability of freedom from re-intervention compared with those with a stable or expanding aneurysm sac (94%, 57%, and 16% at 12 years, respectively; log rank, p < .001). Mean time to re-intervention was 11.3 years for the sac regression group, 8.8 years for the stable sac group, and 5.0 years for the sac expansion group (p < .001). In the stable sac group, the risk of re-intervention increased sharply six years after EVAR, whereas in the sac expansion group a sharp rise in re-intervention was noted 3.5 years after EVAR, reaching a plateau after year 6. CONCLUSION A time dependent correlation between aneurysm sac behaviour and re-intervention was found. Such findings have implications for surveillance strategies.
Collapse
|
118
|
Spath P, Leone M. Reverse Iliac Limb Graft Deployment for Urgent Endovascular Internal Iliac Artery Aneurysm Repair. Eur J Vasc Endovasc Surg 2024; 67:629. [PMID: 37979610 DOI: 10.1016/j.ejvs.2023.11.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Revised: 10/28/2023] [Accepted: 11/14/2023] [Indexed: 11/20/2023]
|
119
|
Fazzini S, Turriziani V, Tonidandel L, Vona S, Ascoli Marchetti A, Ippoliti A, Austermann MJ, Torsello G. Protagoras 3.0: feasibility of current fenestrated endografts and chimney technique for complex abdominal aortic aneurysms. THE JOURNAL OF CARDIOVASCULAR SURGERY 2024; 65:110-118. [PMID: 38635286 DOI: 10.23736/s0021-9509.24.13032-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/19/2024]
Abstract
BACKGROUND The aim of this study was to evaluate the anatomical feasibility of current available fenestrated endografts (FEVAR) and on-label chimney technique (EnChEVAR) in patients with complex abdominal aortic aneurysms (C-AAA). METHODS Feasibility of EnChEVAR (Endurant II/IIS CE-marked [Medtronic]) and 4 types of FEVAR (Zenith Fenestrated CE-marked, Zenith Fenestrated Low-Profile [LP] custom-made device [CMD] [Cook Medical], Fenestrated Anaconda LoPro90 CMD, Fenestrated Treo CMD [Terumo Aortic]) was assessed according to the manufacturer's instructions for use. Computed tomography angiograms of patients with C-AAA previously included in the Protagoras 2.0 study were retrospectively reviewed. The aortic coverage was ideally planned to involve a maximum of two chimney grafts or fenestrations. RESULTS Iliac access and aortic neck of 73 C-AAAs were analyzed. The overall feasibility was significantly different between EnChEVAR (33%) and FEVAR (Zenith Fenestrated 15%, Zenith Fenestrated LP 15%, Fenestrated Anaconda LoPro90 45%, Fenestrated Treo 48%). The iliac access feasibility was significantly lower for Zenith Fenestrated with standard profile compared to all other grafts. The aortic neck feasibility was significantly higher for EnChEVAR and both Terumo Aortic fenestrated stent grafts, compared to both Cook Medical grafts. The treatment using any of the three current available fenestrated grafts with lower profile (Zenith Fenestrated LP, Fenestrated Anaconda LoPro90, Fenestrated Treo) would have been feasible in 71% of the cases. CONCLUSIONS Most of the patients treated by ChEVAR would have not been treated by first generation fenestrated stent graft. The current available fenestrated endografts, with lower profile and suitable also for angulated necks, increase the anatomical feasibility.
Collapse
|
120
|
Skov RAC, Lawaetz J, Stroem M, Van Herzeele I, Resch TA, Eiberg JP. Certification of Basic Skills in Endovascular Aortic Repair Through a Modular Simulation Course With Real Time Performance Assessment. Eur J Vasc Endovasc Surg 2024; 67:672-680. [PMID: 37979611 DOI: 10.1016/j.ejvs.2023.11.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Revised: 10/23/2023] [Accepted: 11/14/2023] [Indexed: 11/20/2023]
Abstract
OBJECTIVE Endovascular aortic repair (EVAR) is being used increasingly for the treatment of infrarenal abdominal aortic aneurysms. Improvement in educational strategies is required to teach future vascular surgeons EVAR skills, but a comprehensive, pre-defined e-learning and simulation curriculum remains to be developed and tested. EndoVascular Aortic Repair Assessment of Technical Expertise (EVARATE), an assessment tool for simulation based education (SBE) in EVAR, has previously been designed to assess EVAR skills, and a pass limit defining mastery level has been set. However, EVARATE was developed for anonymous video ratings in a research setting, and its feasibility for real time ratings in a standardised SBE programme in EVAR is unproven. This study aimed to test the effect of a newly developed simulation based modular course in EVAR. In addition, the applicability of EVARATE for real time performance assessments was investigated. METHODS The European Society of Vascular Surgery (ESVS) and Copenhagen Certification Programme in EVAR (ENHANCE-EVAR) was tested in a prospective cohort study. ENHANCE-EVAR is a modular SBE programme in EVAR consisting of e-learning and hands-on SBE. Participants were rated with the EVARATE tool by experienced EVAR surgeons. RESULTS Twenty-four physicians completed the study. The mean improvement in EVARATE score during the course was +11.8 (95% confidence interval 9.8 - 13.7) points (p < .001). Twenty-two participants (92%) passed with a mean number of 2.8 ± 0.7 test attempts to reach the pass limit. Cronbach's alpha coefficient was 0.91, corresponding to excellent reliability of the EVARATE scale. Differences between instructors' EVARATE ratings were insignificant (p = .16), with a maximum variation between instructors of ± 1.3 points. CONCLUSION ENHANCE-EVAR, a comprehensive certifying EVAR course, was proven to be effective. EndoVascular Aortic Repair Assessment of Technical Expertise (EVARATE) is a trustworthy tool for assessing performance within an authentic educational setting, enabling real time feedback.
Collapse
|
121
|
Li SR, Phillips AR, Reitz KM, Mikati N, Brown JB, Tzeng E, Makaroun MS, Guyette FX, Liang NL. Hypertension during transfer is associated with poor outcomes in unstable patients with ruptured abdominal aortic aneurysm. J Vasc Surg 2024; 79:755-762. [PMID: 38040202 PMCID: PMC11129779 DOI: 10.1016/j.jvs.2023.11.044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 11/09/2023] [Accepted: 11/25/2023] [Indexed: 12/03/2023]
Abstract
OBJECTIVE Limited data exist for optimal blood pressure (BP) management during transfer of patients with ruptured abdominal aortic aneurysm (rAAA). This study evaluates the effects of hypertension and severe hypotension during interhospital transfers in a cohort of patients with rAAA in hemorrhagic shock. METHODS We performed a retrospective, single-institution review of patients with rAAA transferred via air ambulance to a quaternary referral center for repair (2003-2019). Vitals were recorded every 5 minutes in transit. Hypertension was defined as a systolic BP of ≥140 mm Hg. The primary cohort included patients with rAAA with hemorrhagic shock (≥1 episode of a systolic BP of <90 mm Hg) during transfer. The primary analysis compared those who experienced any hypertensive episode to those who did not. A secondary analysis evaluated those with either hypertension or severe hypotension <70 mm Hg. The primary outcome was 30-day mortality. RESULTS Detailed BP data were available for 271 patients, of which 125 (46.1%) had evidence of hemorrhagic shock. The mean age was 74.2 ± 9.1 years, 93 (74.4%) were male, and the median total transport time from helicopter dispatch to arrival at the treatment facility was 65 minutes (interquartile range, 46-79 minutes). Among the cohort with shock, 26.4% (n = 33) had at least one episode of hypertension. There were no significant differences in age, sex, comorbidities, AAA repair type, AAA anatomic location, fluid resuscitation volume, blood transfusion volume, or vasopressor administration between the hypertensive and nonhypertensive groups. Patients with hypertension more frequently received prehospital antihypertensives (15% vs 2%; P = .01) and pain medication (64% vs 24%; P < .001), and had longer transit times (36.3 minutes vs 26.0 minutes; P = .006). Episodes of hypertension were associated with significantly increased 30-day mortality on multivariable logistic regression (adjusted odds ratio [aOR], 4.71; 95% confidence interval [CI], 1.54-14.39; P = .007; 59.4% [n = 19] vs 40.2% [n = 37]; P = .01). Severe hypotension (46%; n = 57) was also associated with higher 30-day mortality (aOR, 2.82; 95% CI, 1.27-6.28; P = .01; 60% [n = 34] vs 32% [n = 22]; P = .01). Those with either hypertension or severe hypotension (54%; n = 66) also had an increased odds of mortality (aOR, 2.95; 95% CI, 1.08-8.11; P = .04; 58% [n = 38] vs 31% [n = 18]; P < .01). Level of hypertension, BP fluctuation, and timing of hypertension were not significantly associated with mortality. CONCLUSIONS Hypertensive and severely hypotensive episodes during interhospital transfer were independently associated with increased 30-day mortality in patients with rAAA with shock. Hypertension should be avoided in these patients, but permissive hypotension approaches should also maintain systolic BPs above 70 mm Hg whenever possible.
Collapse
|
122
|
Fagertun H, Klepstad P, Åldstedt Nyrønning L, Seternes A. Increasing Use of Prophylactic Open Abdomen Therapy With Vacuum Assisted Wound Closure and Mesh Mediated Fascial Traction After Repair of Ruptured Abdominal Aortic Aneurysm. Eur J Vasc Endovasc Surg 2024; 67:603-610. [PMID: 38805011 DOI: 10.1016/j.ejvs.2023.10.032] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Revised: 09/17/2023] [Accepted: 10/23/2023] [Indexed: 05/29/2024]
Abstract
OBJECTIVE Open abdomen therapy (OAT) is commonly used to prevent or treat abdominal compartment syndrome (ACS) in patients with ruptured abdominal aortic aneurysms (rAAAs). This study aimed to evaluate the incidence, treatment, and outcomes of OAT after rAAA from 2006 to 2021. Investigating data on resuscitation fluid, weight gain, and cumulative fluid balance could provide a more systematic approach to determining the timing of safe abdominal closure. METHODS This was a single centre observational cohort study. The study included all patients treated for rAAA followed by OAT from October 2006 to December 2021. RESULTS Seventy-two of the 244 patients who underwent surgery for rAAA received OAT. The mean age was 72 ± 7.85 years, and most were male (n = 61, 85%). The most frequent comorbidities were cardiac disease (n = 31, 43%) and hypertension (n = 31, 43%). Fifty-two patients (72%) received prophylactic OAT, and 20 received OAT for ACS (28%). There was a 25% mortality rate in the prophylactic OAT group compared with the 50% mortality in those who received OAT for ACS (p = .042). The 58 (81%) patients who survived until closure had a median of 12 (interquartile range [IQR] 9, 16.5) days of OAT and 5 (IQR 4, 7) dressing changes. There was one case of colocutaneous fistula and two cases of graft infection. All 58 patients underwent successful abdominal closure, with 55 (95%) undergoing delayed primary closure. In hospital survival was 85%. Treatment trends over time showed the increased use of prophylactic OAT (p ≤ .001) and fewer ACS cases (p = .03) assessed by Fisher's exact test. In multivariable regression analysis fluid overload and weight reduction predicted 26% of variability in time to closure. CONCLUSION Prophylactic OAT after rAAA can be performed safely, with a high rate of delayed primary closure even after long term treatment.
Collapse
|
123
|
González Fernández B, Garcinuño Pérez S, Sánchez-de Prada L, Eiros-Bachiller I, Brizuela Sanz JA, Eiros JM. [Abscess in the psoas secondary to infection of the abdominal aortic stent by Listeria monocytogenes]. REVISTA ESPANOLA DE QUIMIOTERAPIA : PUBLICACION OFICIAL DE LA SOCIEDAD ESPANOLA DE QUIMIOTERAPIA 2024; 37:193-195. [PMID: 38374669 PMCID: PMC10945103 DOI: 10.37201/req/135.2023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/17/2023] [Revised: 01/13/2024] [Accepted: 02/06/2024] [Indexed: 02/21/2024]
|
124
|
Semaan DB, Habib SG, Madigan M, Eid R, Singh MJ, Chaer RA, Makaroun MS, Eslami MH. A Comparison of Surgical Techniques and Outcomes for Primary Infected Abdominal Aortic Aneurysms. Ann Vasc Surg 2024; 101:209-218. [PMID: 38163582 DOI: 10.1016/j.avsg.2023.11.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2023] [Revised: 10/28/2023] [Accepted: 11/05/2023] [Indexed: 01/03/2024]
Abstract
BACKGROUND Primary infected abdominal aortic aneurysms (PIAAAs) are associated with high morbidity and mortality. Three repair approaches include open in-situ repair (OIR), extra-anatomic repair (EAR), and endovascular abdominal aortic aneurysm repair (EVAR). This study is one of the largest single-center case series comparing the outcomes of the different surgical approaches for PIAAA. METHODS This is a retrospective cohort study of all patients treated surgically for PIAAA between 2000 and 2021. PIAAA diagnosis was defined as the presence of an abdominal aortic aneurysm with evidence of infection on clinical presentation, laboratory markers, radiology, or surgically. Patients with prior aortic surgery were excluded from this study. Basic demographics were compared across the 3 surgical groups using standard statistical methods. Our primary outcomes included mortality at 1 and 5 years. Kaplan-Meier curves were generated and compared using log-rank testing. Multivariate Cox proportional hazards models were created to assess determinants of mortality. RESULTS A total of 43 patients were included in the full cohort. Patients undergoing EVAR more often had diabetes, end-stage renal disease, and coronary artery disease. EVAR was also more often done in patients with a saccular aneurysm rather than fusiform. (93% vs. 70% in EAR and 42% in OIR; P = 0.015). All-cause mortality rates at 1 year were not significantly different between the 3 groups. Survival at 5 years did show a significant benefit of OIR over EVAR and EAR: OIR had an 8% mortality rate with EAR having a 53% rate and EVAR having the highest (72%) mortality rate at 5 years (P = 0.03). Multivariable Cox regression analysis showed that EVAR (aHR 12.1, (95% CI 1.42 to 103.9), P = 0.02) and EAR (aHR 15.1, (95% CI 1.59 to 143.3), P = 0.0.02) had an increased 5-year mortality risk when compared to OIR. CONCLUSIONS Repair of primary infected aortic aneurysm is associated with high complication and mortality rates regardless of the approach. In our studied sample, OIR offered an improved long-term survival without added benefits in terms of complication rates. In infected AAA, EVAR should be considered bridging stage between the urgent situation and eventual open repair.
Collapse
|
125
|
Spath P, Campana F, Gallitto E, Pini R, Mascoli C, Sufali G, Caputo S, Sonetto A, Faggioli G, Gargiulo M. Impact of iliac access in elective and non-elective endovascular repair of abdominal aortic aneurysm. THE JOURNAL OF CARDIOVASCULAR SURGERY 2024; 65:85-98. [PMID: 38635284 DOI: 10.23736/s0021-9509.24.12987-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/19/2024]
Abstract
Endovascular aortic repair (EVAR) is nowadays the establishment treatment for patients with abdominal aortic aneurysm (AAA) both in elective and urgent setting. Despite the large applicability and satisfactory results, the presence of hostile iliac anatomy affects both technical and clinical success. This narrative review aimed to report the impact of iliac access and related adjunctive procedures in patients undergoing EVAR in elective and non-elective setting. Hostile iliac access can be defined in presence of narrowed, tortuous, calcified, or occluded iliac arteries. These iliac characteristics can be graded by the anatomic severity grade score to quantitatively assess anatomic complexity before undergoing treatment. Literature shows that iliac hostility has an impact on device navigability, insertion and perioperative and postoperative results. Overall, it has been correlated to higher rate of access issues, representing up to 30% of the first published EVAR experience. Recent innovations with low-profile endografts have reduced large-bore sheaths related issues. However, iliac-related complications still represent an issue, and several adjunctive endovascular and surgical strategies are nowadays available to overcome these complications during EVAR. In urgent settings iliac hostility can significantly impact on particular time sensitive procedures. Moreover, in case of severe hostility patients might be written off for EVAR repair might be inapplicable, exposing to higher mortality/morbidity risk in this urgent/emergent setting. In conclusion, an accurate anatomical evaluation of iliac arteries during preoperative planning, materials availability, and skilled preparation to face iliac-related issues are crucial to address these challenges.
Collapse
|