51
|
Wang W, Fan X, Xu S, Davis JJ, Luo X. Low fouling label-free DNA sensor based on polyethylene glycols decorated with gold nanoparticles for the detection of breast cancer biomarkers. Biosens Bioelectron 2015; 71:51-56. [DOI: 10.1016/j.bios.2015.04.018] [Citation(s) in RCA: 68] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2015] [Revised: 03/30/2015] [Accepted: 04/05/2015] [Indexed: 12/22/2022]
|
52
|
Zhang S, Zhang L, Zhang X, Yang P, Cai J. An efficient nanomaterial-based electrochemical biosensor for sensitive recognition of drug-resistant leukemia cells. Analyst 2015; 139:3629-35. [PMID: 24889704 DOI: 10.1039/c4an00420e] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
A novel electrochemical cytosensor was developed for the fast and high-sensitivity recognition of drug-resistant leukemia K562/ADM cells based on the P-glycoprotein (P-gp) expression level on a cell membrane. The nanocomposite interface of the gold nanoparticles/polyaniline nanofibers (AuNPs/PANI-NF) was chosen to design the biosensor for electrochemical detection. Au/PANI-NF-based cytosensors coated with anti-P-glycoprotein (anti-P-gp) molecules could provide a biomimetic interface for the immunosensing of cell surface P-glycoprotein, and thus could capture the over-expression P-gp cells. Transmission electron microscopy (TEM) indicated that the gold nanoparticles were uniformly anchored along the structure of the PANI-NF surface, displaying fibrillar morphology with a diameter of ∼70 nm, and atomic force microscopy (AFM) further presented the morphology of the nanocomposite film. Owing to the high affinity of anti-P-gp for leukemia K562/ADM cells of the propounded sensing platform, the proposed biosensor exhibited excellent analytical performance for leukemia K562/ADM cells, ranging from 1.6 × 10(2) to 1.6 × 10(6) cells per mL with a detection limit of 80 cells per mL. Recovery experiments indicated that the sensitivity reported here is suitable for practical application. The cell surface P-gp expression level was analysed by flow cytometric experiments, which confirmed the above recognized result. This strategy is also a cost-effective and convenient operation, implying great promise for the sensitive recognition of cancer cells and cell surface receptors; thus, it is helpful in cancer diagnosis.
Collapse
Affiliation(s)
- Shaolian Zhang
- Department of Chemistry, Jinan University, Guangzhou 510632, People's Republic of China.
| | | | | | | | | |
Collapse
|
53
|
Abstract
The use of cancer biomarkers is emerging as one of the most promising strategies for early detection and management of cancer. Biosensors can provide advanced platforms for biomarker analysis with the advantages of being easy to use, inexpensive, rapid and offering multi-analyte testing capability. The intention of this article is to discuss recent advances and trends in affinity biosensors for cancer diagnosis, prognosis and even theragnosis. The different types of affinity biosensors will be reviewed in terms of molecular recognition element. Current challenges and trends for this technology will be also discussed, with a particular emphasis on recent developments in miRNA detection.
Collapse
|
54
|
Ye X, Shi H, He X, Wang K, He D, Yan L, Xu F, Lei Y, Tang J, Yu Y. Iodide-Responsive Cu-Au Nanoparticle-Based Colorimetric Platform for Ultrasensitive Detection of Target Cancer Cells. Anal Chem 2015; 87:7141-7. [PMID: 26100583 DOI: 10.1021/acs.analchem.5b00943] [Citation(s) in RCA: 66] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Colorimetric analysis is promising in developing facile, fast, and point-of-care cancer diagnosis techniques, but the existing colorimetric cancer cell assays remain problematic because of dissatisfactory sensitivity as well as complex probe design or synthesis. To solve the problem, we here present a novel colorimetric analytical strategy based on iodide-responsive Cu-Au nanoparticles (Cu-Au NPs) combined with the iodide-catalyzed H2O2-TMB (3,3,5,5-tetramethylbenzidine) reaction system. In this strategy, bimetallic Cu-Au NPs prepared with an irregular shape and a diameter of ∼15 nm could chemically absorb iodide, thus indirectly inducing colorimetric signal variation of the H2O2-TMB system. By further utilizing its property of easy biomolecule modification, a versatile colorimetric platform was constructed for detection of any target that could cause the change of Cu-Au NPs concentration via molecular recognition. As proof of concept, an analysis of human leukemia CCRF-CEM cells was performed using aptamer Sgc8c-modified Cu-Au NPs as the colorimetric probe. Results showed that Sgc8c-modified Cu-Au NPs successfully achieved a simple, label-free, cost-effective, visualized, selective, and ultrasensitive detection of cancer cells with a linear range from 50 to 500 cells/mL and a detection limit of 5 cells in 100 μL of binding buffer. Moreover, feasibility was demonstrated for cancer cell analysis in diluted serum samples. The iodide-responsive Cu-Au NP-based colorimetric strategy might not only afford a new design pattern for developing cancer cell assays but also greatly extend the application of the iodide-catalyzed colorimetric system.
Collapse
Affiliation(s)
- Xiaosheng Ye
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, College of Biology, Hunan University, Key Laboratory for Bio-Nanotechnology and Molecular Engineering of Hunan Province, Changsha 410082, China
| | - Hui Shi
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, College of Biology, Hunan University, Key Laboratory for Bio-Nanotechnology and Molecular Engineering of Hunan Province, Changsha 410082, China
| | - Xiaoxiao He
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, College of Biology, Hunan University, Key Laboratory for Bio-Nanotechnology and Molecular Engineering of Hunan Province, Changsha 410082, China
| | - Kemin Wang
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, College of Biology, Hunan University, Key Laboratory for Bio-Nanotechnology and Molecular Engineering of Hunan Province, Changsha 410082, China
| | - Dinggeng He
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, College of Biology, Hunan University, Key Laboratory for Bio-Nanotechnology and Molecular Engineering of Hunan Province, Changsha 410082, China
| | - Lv'an Yan
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, College of Biology, Hunan University, Key Laboratory for Bio-Nanotechnology and Molecular Engineering of Hunan Province, Changsha 410082, China
| | - Fengzhou Xu
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, College of Biology, Hunan University, Key Laboratory for Bio-Nanotechnology and Molecular Engineering of Hunan Province, Changsha 410082, China
| | - Yanli Lei
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, College of Biology, Hunan University, Key Laboratory for Bio-Nanotechnology and Molecular Engineering of Hunan Province, Changsha 410082, China
| | - Jinlu Tang
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, College of Biology, Hunan University, Key Laboratory for Bio-Nanotechnology and Molecular Engineering of Hunan Province, Changsha 410082, China
| | - Yanru Yu
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, College of Biology, Hunan University, Key Laboratory for Bio-Nanotechnology and Molecular Engineering of Hunan Province, Changsha 410082, China
| |
Collapse
|
55
|
Sun D, Lu J, Chen Z, Yu Y, Mo M. A repeatable assembling and disassembling electrochemical aptamer cytosensor for ultrasensitive and highly selective detection of human liver cancer cells. Anal Chim Acta 2015; 885:166-73. [PMID: 26231902 DOI: 10.1016/j.aca.2015.05.027] [Citation(s) in RCA: 61] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2015] [Revised: 05/14/2015] [Accepted: 05/15/2015] [Indexed: 11/17/2022]
Abstract
In this work, a repeatable assembling and disassembling electrochemical aptamer cytosensor was proposed for the sensitive detection of human liver hepatocellular carcinoma cells (HepG2) based on a dual recognition and signal amplification strategy. A high-affinity thiolated TLS11a aptamer, covalently attached to a gold electrode through Au-thiol interactions, was adopted to recognize and capture the target HepG2 cells. Meanwhile, the G-quadruplex/hemin/aptamer and horseradish peroxidase (HRP) modified gold nanoparticles (G-quadruplex/hemin/aptamer-AuNPs-HRP) nanoprobe was designed. It could be used for electrochemical cytosensing with specific recognition and enzymatic signal amplification of HRP and G-quadruplex/hemin HRP-mimicking DNAzyme. With the nanoprobes as recognizing probes, the HepG2 cancer cells were captured to fabricate an aptamer-cell-nanoprobes sandwich-like superstructure on a gold electrode surface. The proposed electrochemical cytosensor delivered a wide detection range from 1×10(2) to 1×10(7) cells mL(-1) and high sensitivity with a low detection limit of 30 cells mL(-1). Furthermore, after the electrochemical detection, the activation potential of -0.9 to -1.7V was performed to break Au-thiol bond and regenerate a bare gold electrode surface, while maintaining the good characteristic of being used repeatedly. The changes of gold electrode behavior after assembling and desorption processes were investigated by electrochemical impedance spectroscopy and cyclic voltammetry techniques. These results indicate that the cytosensor has great potential in disease diagnostic of cancers and opens new insight into the reusable gold electrode with repeatable assembling and disassembling in the electrochemical sensing.
Collapse
Affiliation(s)
- Duanping Sun
- School of Pharmaceutical Sciences, Sun Yat-Sen University, Guangzhou 510006, China
| | - Jing Lu
- School of Pharmaceutical Sciences, Sun Yat-Sen University, Guangzhou 510006, China
| | - Zuanguang Chen
- School of Pharmaceutical Sciences, Sun Yat-Sen University, Guangzhou 510006, China.
| | - Yanyan Yu
- School of Pharmaceutical Sciences, Sun Yat-Sen University, Guangzhou 510006, China
| | - Manni Mo
- Department of Chemistry, Faculty of Science, The University of Hong Kong, Hong Kong, China
| |
Collapse
|
56
|
Arkan E, Saber R, Karimi Z, Shamsipur M. A novel antibody–antigen based impedimetric immunosensor for low level detection of HER2 in serum samples of breast cancer patients via modification of a gold nanoparticles decorated multiwall carbon nanotube-ionic liquid electrode. Anal Chim Acta 2015; 874:66-74. [DOI: 10.1016/j.aca.2015.03.022] [Citation(s) in RCA: 90] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2014] [Revised: 03/10/2015] [Accepted: 03/13/2015] [Indexed: 10/23/2022]
|
57
|
Yang F, Yang Z, Zhuo Y, Chai Y, Yuan R. Ultrasensitive electrochemical immunosensor for carbohydrate antigen 19-9 using Au/porous graphene nanocomposites as platform and Au@Pd core/shell bimetallic functionalized graphene nanocomposites as signal enhancers. Biosens Bioelectron 2015; 66:356-62. [DOI: 10.1016/j.bios.2014.10.066] [Citation(s) in RCA: 77] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2014] [Revised: 10/18/2014] [Accepted: 10/29/2014] [Indexed: 01/04/2023]
|
58
|
Wu C, Shah A, Ye H, Chen X, Ye J, Jiang H, Chen B, Wang X, Yan H. Droplet electrochemical study of the pH dependent redox behavior of novel ferrocenyl-carborane derivatives and its application in specific cancer cell recognition. Anal Chim Acta 2015; 857:39-45. [DOI: 10.1016/j.aca.2014.12.019] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2014] [Revised: 12/05/2014] [Accepted: 12/09/2014] [Indexed: 12/21/2022]
|
59
|
Wu X, Chai Y, Zhang P, Yuan R. An electrochemical biosensor for sensitive detection of microRNA-155: combining target recycling with cascade catalysis for signal amplification. ACS APPLIED MATERIALS & INTERFACES 2015; 7:713-20. [PMID: 25495913 DOI: 10.1021/am507059n] [Citation(s) in RCA: 79] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
In this work, a new electrochemical biosensor based on catalyzed hairpin assembly target recycling and cascade electrocatalysis (cytochrome c (Cyt c) and alcohol oxidase (AOx)) for signal amplification was constructed for highly sensitive detection of microRNA (miRNA). It is worth pointing out that target recycling was achieved only based on strand displacement process without the help of nuclease. Moreover, porous TiO2 nanosphere was synthesized, which could offer more surface area for Pt nanoparticles (PtNPs) enwrapping and enhance the amount of immobilized DNA strand 1 (S1) and Cyt c accordingly. With the mimicking sandwich-type reaction, the cascade catalysis amplification strategy was carried out by AOx catalyzing ethanol to acetaldehyde with the concomitant formation of high concentration of H2O2, which was further electrocatalyzed by PtNPs and Cyt c. This newly designed biosensor provided a sensitive detection of miRNA-155 from 0.8 fM to 1 nM with a relatively low detection limit of 0.35 fM.
Collapse
Affiliation(s)
- Xiaoyan Wu
- Key Laboratory of Luminescent and Real-Time Analytical Chemistry (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University , Chongqing 400715, P. R. China
| | | | | | | |
Collapse
|
60
|
Zhao Y, Yang X, Li H, Luo Y, Yu R, Zhang L, Yang Y, Song Q. Au nanoflower–Ag nanoparticle assembled SERS-active substrates for sensitive MC-LR detection. Chem Commun (Camb) 2015; 51:16908-11. [DOI: 10.1039/c5cc05868f] [Citation(s) in RCA: 55] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Au nanoflower–Ag nanoparticle core–satellite assembly engineered Raman aptasensors achieved the sensitive detection of microcystin-LR in Tai lake water.
Collapse
Affiliation(s)
- Yuan Zhao
- The Key Lab of Food Colloids and Biotechnology
- Ministry of Education
- School of Chemical and Material Engineering
- Jiangnan University
- Wuxi
| | - Xuan Yang
- The Key Lab of Food Colloids and Biotechnology
- Ministry of Education
- School of Chemical and Material Engineering
- Jiangnan University
- Wuxi
| | - Hao Li
- The Key Lab of Food Colloids and Biotechnology
- Ministry of Education
- School of Chemical and Material Engineering
- Jiangnan University
- Wuxi
| | - Yaodong Luo
- The Key Lab of Food Colloids and Biotechnology
- Ministry of Education
- School of Chemical and Material Engineering
- Jiangnan University
- Wuxi
| | - Ruipeng Yu
- The Key Lab of Food Colloids and Biotechnology
- Ministry of Education
- School of Chemical and Material Engineering
- Jiangnan University
- Wuxi
| | - Lingling Zhang
- The Key Lab of Food Colloids and Biotechnology
- Ministry of Education
- School of Chemical and Material Engineering
- Jiangnan University
- Wuxi
| | - Yaxin Yang
- The Key Lab of Food Colloids and Biotechnology
- Ministry of Education
- School of Chemical and Material Engineering
- Jiangnan University
- Wuxi
| | - Qijun Song
- The Key Lab of Food Colloids and Biotechnology
- Ministry of Education
- School of Chemical and Material Engineering
- Jiangnan University
- Wuxi
| |
Collapse
|
61
|
Ge S, Lan F, Yu F, Yu J. Applications of graphene and related nanomaterials in analytical chemistry. NEW J CHEM 2015. [DOI: 10.1039/c4nj01783h] [Citation(s) in RCA: 57] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Graphene and its related materials remain a very bright and exciting prospect in analytical chemistry.
Collapse
Affiliation(s)
- Shenguang Ge
- Key Laboratory of Chemical Sensing & Analysis in Universities of Shandong (University of Jinan)
- School of Chemistry and Chemical Engineering
- University of Jinan
- Jinan 250022
- China
| | - Feifei Lan
- Key Laboratory of Chemical Sensing & Analysis in Universities of Shandong (University of Jinan)
- School of Chemistry and Chemical Engineering
- University of Jinan
- Jinan 250022
- China
| | - Feng Yu
- Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan
- School of Chemistry and Chemical Engineering
- Shihezi University
- Shihezi 832003
- China
| | - Jinghua Yu
- Key Laboratory of Chemical Sensing & Analysis in Universities of Shandong (University of Jinan)
- School of Chemistry and Chemical Engineering
- University of Jinan
- Jinan 250022
- China
| |
Collapse
|
62
|
Subramanian AP, Jaganathan SK, Supriyanto E. Overview on in vitro and in vivo investigations of nanocomposite based cancer diagnosis and therapeutics. RSC Adv 2015. [DOI: 10.1039/c5ra11912j] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
The nanodevices are synthesized using nanocomposites by the researchers around the globe. Most of their applications are related to in vivo visualization and therapy with anticancer drugs in the field of oncology.
Collapse
Affiliation(s)
- A. P. Subramanian
- IJN-UTM Cardiovascular Engineering Centre
- Faculty of Biosciences and Medical Engineering
- Universiti Teknologi Malaysia
- Johor Bahru 81310
- Malaysia
| | - S. K. Jaganathan
- IJN-UTM Cardiovascular Engineering Centre
- Faculty of Biosciences and Medical Engineering
- Universiti Teknologi Malaysia
- Johor Bahru 81310
- Malaysia
| | - Eko Supriyanto
- IJN-UTM Cardiovascular Engineering Centre
- Faculty of Biosciences and Medical Engineering
- Universiti Teknologi Malaysia
- Johor Bahru 81310
- Malaysia
| |
Collapse
|
63
|
Abstract
In this critical review, we present the recent advances in the design and fabrication of graphene/nucleic acid nanobiointerfaces, as well as the fundamental understanding of their interfacial properties and various nanobiotechnological applications.
Collapse
Affiliation(s)
- Longhua Tang
- State Key Laboratory of Modern Optical Instrumentation
- Department of Optical Engineering
- Zhejiang University
- Hangzhou 310027
- China
| | - Ying Wang
- Department of Chemistry
- Shanghai Key Laboratory of Chemical Assessment and Sustainability
- UNEP-Tongji Institute of Environment for Sustainable Development
- Tongji University
- Shanghai
| | - Jinghong Li
- Department of Chemistry
- Beijing Key Laboratory for Microanalytical Methods and Instrumentation
- Tsinghua University
- Beijing 100084
- China
| |
Collapse
|
64
|
Gedi V, Kim YP. Detection and characterization of cancer cells and pathogenic bacteria using aptamer-based nano-conjugates. SENSORS (BASEL, SWITZERLAND) 2014; 14:18302-27. [PMID: 25268922 PMCID: PMC4239906 DOI: 10.3390/s141018302] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/17/2014] [Revised: 08/08/2014] [Accepted: 09/02/2014] [Indexed: 12/30/2022]
Abstract
Detection and characterization of cells using aptamers and aptamer-conjugated nanoprobes has evolved a great deal over the past few decades. This evolution has been driven by the easy selection of aptamers via in vitro cell-SELEX, permitting sensitive discrimination between target and normal cells, which includes pathogenic prokaryotic and cancerous eukaryotic cells. Additionally, when the aptamer-based strategies are used in conjunction with nanomaterials, there is the potential for cell targeting and therapeutic effects with improved specificity and sensitivity. Here we review recent advances in aptamer-based nano-conjugates and their applications for detecting cancer cells and pathogenic bacteria. The multidisciplinary research utilized in this field will play an increasingly significant role in clinical medicine and drug discovery.
Collapse
Affiliation(s)
- Vinayakumar Gedi
- Department of Life Science, Hanyang University, Seoul 133-791, Korea.
| | - Young-Pil Kim
- Department of Life Science, Hanyang University, Seoul 133-791, Korea.
| |
Collapse
|
65
|
Jing P, Xu W, Yi H, Wu Y, Bai L, Yuan R. An amplified electrochemical aptasensor for thrombin detection based on pseudobienzymic Fe3O4-Au nanocomposites and electroactive hemin/G-quadruplex as signal enhancers. Analyst 2014; 139:1756-61. [PMID: 24519466 DOI: 10.1039/c3an02237d] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A sensitive and selective electrochemical aptasensor for thrombin detection was constructed based on hemin/G-quadruplex as the signal label and Fe3O4-Au nanocomposites with glucose oxidase (GOx-) and peroxide-mimicking enzyme activity as the signal enhancers. Due to their large surface area and good biocompatibility, Fe3O4-Au nanocomposites were employed to immobilize electroactive hemin/G-quadruplex, which was formed by the conjugation between a single-stranded guanine-rich nucleic acid and hemin. Based on the GOx-mimicking enzyme activity, Au nanoparticles on the surface of the Fe3O4-Au nanocomposites effectively catalyzed the oxidization of glucose in the presence of dissolved O2, accompanied by the production of H2O2. Both the Fe3O4 cores of Fe3O4-Au nanocomposites and hemin/G-quadruplex with H2O2-mimicking enzyme activity could catalyze the reduction of the generated H2O2, which promoted the electron transfer of hemin and amplified the electrochemical signal. The proposed electrochemical aptasensor had a wide dynamic linear range of 0.1 pM to 20 nM with a lower detection limit of 0.013 pM, which provided a promising method for a sensitive assay for the detection of proteins in electrochemical aptasensors.
Collapse
Affiliation(s)
- Pei Jing
- Education Ministry Key Laboratory on Luminescence and Real-TimeAnalysis, School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, People's Republic of China.
| | | | | | | | | | | |
Collapse
|
66
|
Ping J, Zhou Y, Wu Y, Papper V, Boujday S, Marks RS, Steele TWJ. Recent advances in aptasensors based on graphene and graphene-like nanomaterials. Biosens Bioelectron 2014; 64:373-85. [PMID: 25261843 DOI: 10.1016/j.bios.2014.08.090] [Citation(s) in RCA: 106] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2014] [Revised: 08/14/2014] [Accepted: 08/27/2014] [Indexed: 11/28/2022]
Abstract
Graphene and graphene-like two-dimensional nanomaterials have aroused tremendous research interest in recent years due to their unique electronic, optical, and mechanical properties associated with their planar structure. Aptamers have exhibited many advantages as molecular recognition elements for sensing devices compared to traditional antibodies. The marriage of two-dimensional nanomaterials and aptamers has emerged many ingenious aptasensing strategies for applications in the fields of clinical diagnosis and food safety. This review highlights current advances in the development and application of two-dimensional nanomaterials-based aptasensors with the focus on two main signal-transducing mechanisms, i.e. electrochemical and optical. A special attention is paid to graphene, a one-atom thick layer of graphite with exceptional properties, representing a fastgrowing field of research. In view of the unique properties of two-dimensional nanostructures and their inherent advantages of synthetic aptamers, we expect that high-performance two-dimensional nanomaterials-based aptasensing devices will find extensive applications in environmental monitoring, biomedical diagnostics, and food safety.
Collapse
Affiliation(s)
- Jianfeng Ping
- School of Materials Science & Engineering, College of Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore
| | - Yubin Zhou
- School of Materials Science & Engineering, College of Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore
| | - Yuanyuan Wu
- School of Materials Science & Engineering, College of Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore
| | - Vladislav Papper
- School of Materials Science & Engineering, College of Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore
| | - Souhir Boujday
- Sorbonne Universités, UPMC, Univ Paris 6, UMR CNRS 7197, Laboratoire de Réactivité de Surface, F-75005 Paris, France; CNRS, UMR 7197, Laboratoire de Réactivité de Surface, F-75005 Paris, France
| | - Robert S Marks
- Department of Biotechnology Engineering, and The Ilse Katz Center for Meso and Nanoscale Science, Faculty of Engineering Sciences, Ben Gurion University of the Negev, P.O. Box 653, Beer Sheva 84105, Israel
| | - Terry W J Steele
- School of Materials Science & Engineering, College of Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore.
| |
Collapse
|
67
|
Wehbe M, Labib M, Muharemagic D, Zamay AS, Berezovski MV. Switchable aptamers for biosensing and bioseparation of viruses (SwAps-V). Biosens Bioelectron 2014; 67:280-6. [PMID: 25190090 DOI: 10.1016/j.bios.2014.08.033] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2014] [Revised: 08/08/2014] [Accepted: 08/18/2014] [Indexed: 11/29/2022]
Abstract
There is a widespread interest in the development of aptamer-based affinity chromatographic methods for purification of biomolecules. Regardless of the many advantages exhibited by aptamers when compared to other recognition elements, the lack of an efficient regeneration technique that can be generalized to all targets has encumbered further integration of aptamers into affinity-based purification methods. Here we offer switchable aptamers (SwAps) that have been developed to solve this problem and move aptamer-based chromatography forward. SwAps are controlled-affinity aptamers, which have been employed here to purify vesicular stomatitis virus (VSV) as a model case, however this technique can be extended to all biologically significant molecules. VSV is one oncolytic virus out of an arsenal of potential candidates shown to provide selective destruction of cancer cells both in vitro and in vivo. These SwAps were developed in the presence of Ca(2+) and Mg(2+) ions where they cannot bind to their target VSV in absence of these cations. Upon addition of EDTA and EGTA, the divalent cations were sequestered from the stabilized aptameric structure causing a conformational change and subsequently release of the virus. Both flow cytometry and electrochemical impedance spectroscopy were employed to estimate the binding affinities between the selected SwAps and VSV and to determine the coefficient of switching (CoS) upon elution. Among fifteen sequenced SwAps, four have exhibited high affinity to VSV and ability to switch upon elution and thus were further integrated into streptavidin-coated magnetic beads for purification of VSV.
Collapse
Affiliation(s)
- Mohamed Wehbe
- Department of Chemistry, University of Ottawa, Ottawa, Ontario, Canada
| | - Mahmoud Labib
- Department of Chemistry, University of Ottawa, Ottawa, Ontario, Canada
| | | | - Anna S Zamay
- Department of Chemistry, University of Ottawa, Ottawa, Ontario, Canada; Institute of Chemistry and Chemical Technology SB RAS, 50 Akademgorodok, Krasnoyarsk 660036, Russia
| | | |
Collapse
|
68
|
Liu Q, Jin C, Wang Y, Fang X, Zhang X, Chen Z, Tan W. Aptamer-conjugated nanomaterials for specific cancer cell recognition and targeted cancer therapy. NPG ASIA MATERIALS 2014; 6:e95. [PMID: 29619132 PMCID: PMC5880215 DOI: 10.1038/am.2014.12] [Citation(s) in RCA: 73] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Based on their unique advantages, increasing interest has been shown in the use of aptamers as target ligands for specific cancer cell recognition and targeted cancer therapy. Recently, the development of aptamer-conjugated nanomaterials has offered new therapeutic opportunities for cancer treatment with better efficacy and lower toxicity. We highlight some of the promising classes of aptamer-conjugated nanomaterials for the specific recognition of cancer cells and targeted cancer therapy. Recent developments in the use of novel strategies that enable sensitive and selective cancer cell recognition are introduced. In addition to targeted drug delivery for chemotherapy, we also review how aptamer-conjugated nanomaterials are being incorporated into emerging technologies with significant improvement in efficiency and selectivity in cancer treatment.
Collapse
Affiliation(s)
- Qiaoling Liu
- Molecular Science and Biomedicine Laboratory, State Key Laboratory of Chemo/Bio-Sensing and Chemometrics, College of Biology, College of Chemistry and Chemical Engineering, Collaborative Innovation Center for Chemistry and Molecular Medicine, Hunan University, Changsha, China
- Beijing National Laboratory for Molecular Sciences, Institute of Chemistry, Chinese Academy of Sciences, Beijing, P.R. China
| | - Chen Jin
- Molecular Science and Biomedicine Laboratory, State Key Laboratory of Chemo/Bio-Sensing and Chemometrics, College of Biology, College of Chemistry and Chemical Engineering, Collaborative Innovation Center for Chemistry and Molecular Medicine, Hunan University, Changsha, China
| | - Yanyue Wang
- Departments of Chemistry, Physiology and Functional Genomics, Molecular Genetics and Microbiology, and Pathology and Laboratory Medicine, Shands Cancer Center, Center for Research at the Bio/Nano Interface, University of Florida, Gainesville, FL, USA
| | - Xiaohong Fang
- Beijing National Laboratory for Molecular Sciences, Institute of Chemistry, Chinese Academy of Sciences, Beijing, P.R. China
| | - Xiaobing Zhang
- Molecular Science and Biomedicine Laboratory, State Key Laboratory of Chemo/Bio-Sensing and Chemometrics, College of Biology, College of Chemistry and Chemical Engineering, Collaborative Innovation Center for Chemistry and Molecular Medicine, Hunan University, Changsha, China
| | - Zhuo Chen
- Molecular Science and Biomedicine Laboratory, State Key Laboratory of Chemo/Bio-Sensing and Chemometrics, College of Biology, College of Chemistry and Chemical Engineering, Collaborative Innovation Center for Chemistry and Molecular Medicine, Hunan University, Changsha, China
| | - Weihong Tan
- Molecular Science and Biomedicine Laboratory, State Key Laboratory of Chemo/Bio-Sensing and Chemometrics, College of Biology, College of Chemistry and Chemical Engineering, Collaborative Innovation Center for Chemistry and Molecular Medicine, Hunan University, Changsha, China
- Departments of Chemistry, Physiology and Functional Genomics, Molecular Genetics and Microbiology, and Pathology and Laboratory Medicine, Shands Cancer Center, Center for Research at the Bio/Nano Interface, University of Florida, Gainesville, FL, USA
| |
Collapse
|
69
|
Taleat Z, Cristea C, Marrazza G, Mazloum-Ardakani M, Săndulescu R. Electrochemical immunoassay based on aptamer–protein interaction and functionalized polymer for cancer biomarker detection. J Electroanal Chem (Lausanne) 2014. [DOI: 10.1016/j.jelechem.2014.01.015] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|