51
|
Affiliation(s)
- Urvashi Mulasi
- Department of Food Science and Nutrition, University of Minnesota–Twin Cities, Saint Paul, Minnesota
| | - Adam J. Kuchnia
- Department of Food Science and Nutrition, University of Minnesota–Twin Cities, Saint Paul, Minnesota
| | - Abigail J. Cole
- Department of Food Science and Nutrition, University of Minnesota–Twin Cities, Saint Paul, Minnesota
| | - Carrie P. Earthman
- Department of Food Science and Nutrition, University of Minnesota–Twin Cities, Saint Paul, Minnesota
| |
Collapse
|
52
|
Weyer S, Menden T, Leicht L, Leonhardt S, Wartzek T. Development of a wearable multi-frequency impedance cardiography device. J Med Eng Technol 2015; 39:131-7. [PMID: 25559781 DOI: 10.3109/03091902.2014.990161] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Cardiovascular diseases as well as pulmonary oedema can be early diagnosed using vital signs and thoracic bio-impedance. By recording the electrocardiogram (ECG) and the impedance cardiogram (ICG), vital parameters are captured continuously. The aim of this study is the continuous monitoring of ECG and multi-frequency ICG by a mobile system. A mobile measuring system, based on 'low-power' ECG, ICG and an included radio transmission is described. Due to the high component integration, a board size of only 6.5 cm×5 cm could be realized. The measured data can be transmitted via Bluetooth and visualized on a portable monitor. By using energy-efficient hardware, the system can operate for up to 18 hs with a 3 V battery, continuously sending data via Bluetooth. Longer operating times can be realized by decreased transfer rates. The relative error of the impedance measurement was less than 1%. The ECG and ICG measurements allow an approximate calculation of the heart stroke volume. The ECG and the measured impedance showed a high correlation to commercial devices (r=0.83, p<0.05). In addition to commercial devices, the developed system allows a multi-frequency measurement of the thoracic impedance between 5-150 kHz.
Collapse
Affiliation(s)
- Sören Weyer
- Medical Information Technology, Helmholtz Institute for Biomedical Engineering, RWTH Aachen University , Aachen , Germany
| | | | | | | | | |
Collapse
|
53
|
Kinosian B. Twenty-First Century Home-Centered Medicine: It's About the Touch, Not the Tech…. J Am Geriatr Soc 2014; 62:2433-5. [DOI: 10.1111/jgs.13176] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Bruce Kinosian
- Division of Geriatrics; Perelman School of Medicine; Leonard Davis Institute of Health Economics; University of Pennsylvania; Philadelphia Pennsylvania
- Geriatrics and Extended Care Data Analysis Center; Center for Health Equity Research and Promotion; Philadelphia Veterans Affairs Medical Center; Philadelphia Pennsylvania
| |
Collapse
|
54
|
Analysis of different device-based intrathoracic impedance vectors for detection of heart failure events (from the Detect Fluid Early from Intrathoracic Impedance Monitoring study). Am J Cardiol 2014; 114:1249-56. [PMID: 25150135 DOI: 10.1016/j.amjcard.2014.07.048] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/12/2014] [Revised: 07/16/2014] [Accepted: 07/16/2014] [Indexed: 11/22/2022]
Abstract
Detect Fluid Early from Intrathoracic Impedance Monitoring (DEFEAT-PE) is a prospective, multicenter study of multiple intrathoracic impedance vectors to detect pulmonary congestion (PC) events. Changes in intrathoracic impedance between the right ventricular (RV) coil and device can (RVcoil→Can) of implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy ICDs (CRT-Ds) are used clinically for the detection of PC events, but other impedance vectors and algorithms have not been studied prospectively. An initial 75-patient study was used to derive optimal impedance vectors to detect PC events, with 2 vector combinations selected for prospective analysis in DEFEAT-PE (ICD vectors: RVring→Can + RVcoil→Can, detection threshold 13 days; CRT-D vectors: left ventricular ring→Can + RVcoil→Can, detection threshold 14 days). Impedance changes were considered true positive if detected <30 days before an adjudicated PC event. One hundred sixty-two patients were enrolled (80 with ICDs and 82 with CRT-Ds), all with ≥1 previous PC event. One hundred forty-four patients provided study data, with 214 patient-years of follow-up and 139 PC events. Sensitivity for PC events of the prespecified algorithms was as follows: ICD: sensitivity 32.3%, false-positive rate 1.28 per patient-year; CRT-D: sensitivity 32.4%, false-positive rate 1.66 per patient-year. An alternative algorithm, ultimately approved by the US Food and Drug Administration (RVring→Can + RVcoil→Can, detection threshold 14 days), resulted in (for all patients) sensitivity of 21.6% and a false-positive rate of 0.9 per patient-year. The CRT-D thoracic impedance vector algorithm selected in the derivation study was not superior to the ICD algorithm RVring→Can + RVcoil→Can when studied prospectively. In conclusion, to achieve an acceptably low false-positive rate, the intrathoracic impedance algorithms studied in DEFEAT-PE resulted in low sensitivity for the prediction of heart failure events.
Collapse
|
55
|
Kim CH, Fuglestad MA, Richert MLC, Shen WK, Johnson BD. Influence of lung volume, fluid and capillary recruitment during positional changes and exercise on thoracic impedance in heart failure. Respir Physiol Neurobiol 2014; 202:75-81. [PMID: 25128641 DOI: 10.1016/j.resp.2014.08.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2014] [Revised: 07/21/2014] [Accepted: 08/07/2014] [Indexed: 12/31/2022]
Abstract
UNLABELLED It is unclear how dynamic changes in pulmonary-capillary blood volume (Vc), alveolar lung volume (derived from end-inspiratory lung volume, EILV) and interstitial fluid (ratio of alveolar capillary membrane conductance and pulmonary capillary blood volume, Dm/Vc) influence lung impedance (Z(T)). The purpose of this study was to investigate if positional change and exercise result in increased EILV, Vc and/or lung interstitial fluid, and if Z(T) tracks these variables. METHODS 12 heart failure (HF) patients underwent measurements (Z(T), EILV, Vc/Dm) at rest in the upright and supine positions, during exercise and into recovery. Inspiratory capacity was obtained to provide consistent measures of EILV while assessing Z(T). RESULTS Z(T) increased with lung volume during slow vital capacity maneuvers (p<0.05). Positional change (upright→supine) resulted in an increased Z(T) (p<0.01), while Vc increased and EILV and Dm/Vc decreased (p<0.05). Moreover, during exercise Vc and EILV increased and Dm/Vc decreased (p<0.05), whereas, Z(T) did not change significantly (p>0.05). CONCLUSION Impedance appears sensitive to changes in lung volume and body position which appear to generally overwhelm small acute changes in lung fluid when assed dynamically at rest or during exercise.
Collapse
Affiliation(s)
- Chul-Ho Kim
- Division of Cardiovascular Diseases, Mayo Clinic, Rochester, MN, United States.
| | - Matthew A Fuglestad
- Division of Cardiovascular Diseases, Mayo Clinic, Rochester, MN, United States
| | | | - Win K Shen
- Division of Cardiovascular Diseases, Mayo Clinic, Scottsdale, AZ, United States
| | - Bruce D Johnson
- Division of Cardiovascular Diseases, Mayo Clinic, Rochester, MN, United States
| |
Collapse
|
56
|
Gudmundsson K, Lyngå P, Karlsson H, Rosenqvist M, Braunschweig F. Midsummer Eve in Sweden: a natural fluid challenge in patients with heart failure. Eur J Heart Fail 2014; 13:1172-7. [DOI: 10.1093/eurjhf/hfr124] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
Affiliation(s)
- Kristjan Gudmundsson
- Karolinska Institutet, Department of Cardiology; Karolinska University Hospital; Stockholm Sweden
| | - Patrik Lyngå
- Karolinska Institutet, Department of Cardiology; Södersjukhuset; Stockholm Sweden
| | - Helena Karlsson
- Karolinska Institutet, Department of Cardiology; Karolinska University Hospital; Stockholm Sweden
| | - Mårten Rosenqvist
- Karolinska Institutet, Department of Cardiology; Södersjukhuset; Stockholm Sweden
| | - Frieder Braunschweig
- Karolinska Institutet, Department of Cardiology; Karolinska University Hospital; Stockholm Sweden
| |
Collapse
|
57
|
Nakamura T, Hirayama M, Hara T, Mizutani Y, Suzuki J, Watanabe H, Sobue G. Role of cardiac sympathetic nerves in preventing orthostatic hypotension in Parkinson's disease. Parkinsonism Relat Disord 2014; 20:409-14. [PMID: 24462345 DOI: 10.1016/j.parkreldis.2014.01.003] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/19/2013] [Revised: 12/22/2013] [Accepted: 01/04/2014] [Indexed: 01/15/2023]
Abstract
PURPOSE Cardiac sympathetic denervation is associated with orthostatic hypotension (OH) in Parkinson's disease (PD); however, the physiological role of cardiac sympathetic nerves has yet to be elucidated. To clarify the role of the heart in orthostatic stress, we evaluated whether cardiac sympathetic nerves can alter cardiac activity and systolic blood pressure (BP) in association with elevations or depressions of total peripheral resistance during the head-up tilt test. METHODS Ninety-five PD patients and 17 normal controls were enrolled. Using impedance cardiography, we measured total peripheral resistance, stroke volume, heart rate, and systolic BP during the head-up tilt test. Cardiac denervation was defined as a heart-to-mediastinum ratio <1.7 for cardiac (123)I-metaiodobenzylguanidine uptake on delayed images. RESULTS At 60° tilt, total peripheral resistance decreased from the initial value in 49 PD patients. Among these, 36 patients exhibited cardiac denervation with severe reductions in systolic BP but little change in stroke volume; among these patients 22 had OH. The remaining 13 patients without cardiac denervation exhibited significant increases in stroke volume and well-preserved systolic BP with no OH. On the other hand, 46 patients had elevations in total peripheral resistance and reduced stroke volume, but little change in systolic BP, regardless of the presence or absence of cardiac denervation. Only one of these patients experienced OH. CONCLUSION Under orthostatic stress, cardiac sympathetic denervation with failure to increase total peripheral resistance leads to large reductions in systolic BP. However, patients without cardiac denervation exhibited a positive inotropic response against vasodilatation, which may prevent OH.
Collapse
Affiliation(s)
- Tomohiko Nakamura
- Department of Neurology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550, Japan; Department of Laboratory Medicine, Nagoya University Hospital, Nagoya, Japan
| | - Masaaki Hirayama
- Department of Pathophysiological Laboratory Sciences, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Takashi Hara
- Department of Neurology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550, Japan; Department of Neurology, Chutoen General Medical Center, Shizuoka, Japan
| | - Yasuaki Mizutani
- Department of Neurology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550, Japan
| | - Junichiro Suzuki
- Department of Neurology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550, Japan
| | - Hirohisa Watanabe
- Department of Neurology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550, Japan
| | - Gen Sobue
- Department of Neurology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550, Japan.
| |
Collapse
|
58
|
Poscente MD, Wang G, Filip D, Ninova P, Yadid-Pecht O, Andrews CN, Mintchev MP. Real-time gastric motility monitoring using transcutaneous intraluminal impedance measurements (TIIM). Physiol Meas 2014; 35:217-29. [PMID: 24398539 DOI: 10.1088/0967-3334/35/2/217] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
The stomach plays a critical role in digestion, processing ingested food mechanically and breaking it up into particles, which can be effectively and efficiently processed by the intestines. When the motility of the stomach is compromised, digestion is adversely affected. This can lead to a variety of disorders. Current diagnostic techniques for gastric motility disorders are seriously lacking, and are based more on eliminating other possibilities rather than on specific tests. Presently, gastric motility can be assessed by monitoring gastric emptying, food transit, intragastric pressures, etc. The associated tests are usually stationary and of relatively short duration. The present study proposes a new method of measuring gastric motility, utilizing the attenuation of an oscillator-induced electrical signal across the gastric tissue, which is modulated by gastric contractions. The induced high-frequency oscillator signal is generated within the stomach, and is picked up transluminally by cutaneous electrodes positioned on the abdominal area connected to a custom-designed data acquisition instrument. The proposed method was implemented in two different designs: first a transoral catheter was modified to emit the signal inside the stomach; and second, a gastric retentive pill was designed to emit the signal. Both implementations were applied in vivo on two mongrel dogs (25.50 kg and 25.75 kg). Gastric contractions were registered and quantitatively compared to recordings from force transducers sutured onto the serosa of the stomach. Gastric motility indices were calculated for each minute, with transluminal impedance measurements and the measurements from the force transducers showing statistically significant (p < 0.05) Pearson correlation coefficients (0.65 ± 0.08 for the catheter-based design and 0.77 ± 0.03 for the gastric retentive pill design). These results show that transcutaneous intraluminal impedance measurement has the potential with further research and development to become a useful diagnostic technique.
Collapse
Affiliation(s)
- M D Poscente
- Centre for Bioengineering Research and Education, University of Calgary, Calgary, Alberta, Canada
| | | | | | | | | | | | | |
Collapse
|
59
|
Noninvasive cardiac monitoring in pregnancy: impedance cardiography versus echocardiography. J Perinatol 2013; 33:675-80. [PMID: 23680787 PMCID: PMC3751992 DOI: 10.1038/jp.2013.35] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/17/2012] [Revised: 01/16/2013] [Accepted: 02/12/2013] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The objective of this study was to report thoracic impedance cardiography (ICG) measurements and compare them with echocardiography (echo) measurements throughout pregnancy and in varied maternal positions. METHOD A prospective cohort study involving 28 healthy parturients was performed using ICG and echo at three time points and in two maternal positions. Pearson's correlations, Bland-Altman plots and paired t-tests were used for statistical analysis. RESULT Significant agreements between many but not all ICG and echo contractility, flow and resistance measurements were demonstrated. Differences in stroke volume (SV) due to maternal position were also detected by ICG in the antepartum (AP) period. Significant trends were observed by ICG for cardiac output and thoracic fluid content (TFC; P<0.025) with advancing pregnancy stages. CONCLUSION ICG and echo demonstrate significant correlations in some but not all measurements of cardiac function. ICG has the ability to detect small changes in SV associated with maternal position change. ICG measurements reflected maximal cardiac contractility in the a AP period yet reflected a decrease in contractility and an increase in TFC in the postpartum period.
Collapse
|
60
|
Hayn D, Fruhwald F, Riedel A, Falgenhauer M, Schreier G. Leg edema quantification for heart failure patients via 3D imaging. SENSORS 2013; 13:10584-98. [PMID: 23948874 PMCID: PMC3812619 DOI: 10.3390/s130810584] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/25/2013] [Revised: 07/31/2013] [Accepted: 08/12/2013] [Indexed: 11/22/2022]
Abstract
Heart failure is a common cardiac disease in elderly patients. After discharge, approximately 50% of all patients are readmitted to a hospital within six months. Recent studies show that home monitoring of heart failure patients can reduce the number of readmissions. Still, a large number of false positive alarms as well as underdiagnoses in other cases require more accurate alarm generation algorithms. New low-cost sensors for leg edema detection could be the missing link to help home monitoring to its breakthrough. We evaluated a 3D camera-based measurement setup in order to geometrically detect and quantify leg edemas. 3D images of legs were taken and geometric parameters were extracted semi-automatically from the images. Intra-subject variability for five healthy subjects was evaluated. Thereafter, correlation of 3D parameters with body weight and leg circumference was assessed during a clinical study at the Medical University of Graz. Strong correlation was found in between both reference values and instep height, while correlation in between curvature of the lower leg and references was very low. We conclude that 3D imaging might be a useful and cost-effective extension of home monitoring for heart failure patients, though further (prospective) studies are needed.
Collapse
Affiliation(s)
- Dieter Hayn
- Safety and Security Department, AIT Austrian Institute of Technology, Reininghausstr. 13, Graz 8020, Austria; E-Mails: (M.F.); (G.S.)
- Author to whom correspondence should be addressed; E-Mail: ; Tel.: +43-50550-2953; Fax: +43-50550-2950
| | - Friedrich Fruhwald
- Department of Cardiology, Medical University of Graz, Auenbruggerplatz 15, Graz 8036, Austria; E-Mails: (F.F.); (A.R.)
- Ludwig Boltzmann Institute for Translational Heart Failure Research, Stiftingtalstrasse 24, Graz 8010, Austria
| | - Arthur Riedel
- Department of Cardiology, Medical University of Graz, Auenbruggerplatz 15, Graz 8036, Austria; E-Mails: (F.F.); (A.R.)
| | - Markus Falgenhauer
- Safety and Security Department, AIT Austrian Institute of Technology, Reininghausstr. 13, Graz 8020, Austria; E-Mails: (M.F.); (G.S.)
| | - Günter Schreier
- Safety and Security Department, AIT Austrian Institute of Technology, Reininghausstr. 13, Graz 8020, Austria; E-Mails: (M.F.); (G.S.)
| |
Collapse
|
61
|
Faini A, Omboni S, Tifrea M, Bubenek S, Lazar O, Parati G. Cardiac index assessment: Validation of a new non-invasive very low current thoracic bioimpedance device by thermodilution. Blood Press 2013; 23:102-8. [DOI: 10.3109/08037051.2013.817121] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
62
|
Evolution of bioimpedance: a circuitous journey from estimation of physiological function to assessment of body composition and a return to clinical research. Eur J Clin Nutr 2013; 67 Suppl 1:S2-9. [PMID: 23299867 DOI: 10.1038/ejcn.2012.149] [Citation(s) in RCA: 192] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
BACKGROUND/OBJECTIVES Bioimpedance is the collective term that describes safe, non-invasive methods to measure the electrical responses to the introduction of a low-level, alternating current into a living organism, and the biophysical models to estimate body composition from bioelectrical measurements. Although bioimpedance techniques have been used for more than 100 years to monitor assorted biological components, the desire to translate bioelectrical measurements into physiological variables advanced the creation of empirical prediction models that produced inconsistent results. SUBJECTS/METHODS This paper succinctly reviews the origin, and critically evaluates the conceptual models and the implementation of bioimpedance in clinical research, including indirect assessment of assorted physiological functions and body composition (fluid volumes and fat-free mass), classification of hydration, regional fluid accumulation, prognosis in disease and wound healing. RESULTS Despite widespread and mounting interest in the use of bioimpedance to characterise body structure and function, most experimental findings reveal the limitations of existing physical models and reliance on multiple regression models for use in assessments of an individual. CONCLUSIONS Contemporary applications of bioimpedance emphasise the value of bioimpedance variables per se in some novel biomedical applications with the objective of identifying opportunities for future outcome-based research.
Collapse
|
63
|
Chiu HW, Chuang JM, Lu CC, Lin WT, Lin CW, Lin ML. In situ measurement of tissue impedance using an inductive coupling interface circuit. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2013; 7:225-235. [PMID: 23853322 DOI: 10.1109/tbcas.2012.2199488] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
In this work, a method of an inductive coupling impedance measurement (ICIM) is proposed for measuring the nerve impedance of a dorsal root ganglion (DRG) under PRF stimulation. ICIM provides a contactless interface for measuring the reflected impedance by an impedance analyzer with a low excitation voltage of 7 mV. The paper develops a calibration procedure involving a 50-Ω reference resistor to calibrate the reflected resistance for measuring resistance of the nerve in the test. A de-embedding technique to build the equivalent transformer circuit model for the ICIM circuit is also presented. A batteryless PRF stimulator with ICIM circuit demonstrated good accuracy for the acute measurement of DRG impedance both in situ and in vivo. Besides, an in vivo animal experiment was conducted to show that the effectiveness of pulsed radiofrequency (PRF) stimulation in relieving pain gradually declined as the impedance of the stimulated nerve increased. The experiment also revealed that the excitation voltage for measuring impedance below 25 mV can prevent the excitation of a nonlinear response of DRG.
Collapse
Affiliation(s)
- Hung-Wei Chiu
- Department of Electronic Engineering and Graduate Institute of Computer and Communication Engineering, National Taipei University of Technology, Taipei 10608, Taiwan.
| | | | | | | | | | | |
Collapse
|
64
|
Kataoka H. Evaluation of short-term changes in body fluid status by a novel method using a commercially available body-fat analyzer: Observations from maintenance hemodialysis patients. Int J Cardiol 2013; 165:208-10. [DOI: 10.1016/j.ijcard.2012.08.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/25/2012] [Accepted: 08/22/2012] [Indexed: 11/25/2022]
|
65
|
Fontecave-Jallon J, Guméry PY, Calabrese P, Briot R, Baconnier P. A Wearable Technology Revisited for Cardio-Respiratory Functional Exploration. INTERNATIONAL JOURNAL OF E-HEALTH AND MEDICAL COMMUNICATIONS 2013. [DOI: 10.4018/jehmc.2013010102] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
The objective of the present study is to extract new information from complex signals generated by Respiratory Inductive Plethysmography (RIP). This indirect cardio-respiratory (CR) measure is a well-known wearable solution. The authors applied time-scale analysis to estimate cardiac activity from thoracic volume variations, witnesses of CR interactions. Calibrated RIP signals gathered from 4 healthy volunteers in resting conditions are processed by Ensemble Empirical Mode Decomposition to extract cardiac volume signals and estimate stroke volumes. Averaged values of these stroke volumes (SVRIP) are compared with averaged values of stroke volumes determined simultaneously by electrical impedance cardiography (SVICG). There is a satisfactory correlation between SVRIP and SVICG (r=0.76, p<0.001) and the limits of agreement between the 2 types of measurements (±23%) satisfies the required criterion (±30%). The observed under-estimation (-58%) is argued. This validates the use of RIP for following stroke volume variations and suggests that one simple transducer can provide a quantitative exploration of both ventilatory and cardiac volumes.
Collapse
Affiliation(s)
- Julie Fontecave-Jallon
- University Joseph Fourier-Grenoble 1, CNRS, TIMC-IMAG Laboratory CNRS UMR 5525, PRETA team, Grenoble, F-38041, France
| | - Pierre-Yves Guméry
- University Joseph Fourier-Grenoble 1, CNRS, TIMC-IMAG Laboratory CNRS UMR 5525, PRETA team, Grenoble, F-38041, France
| | - Pascale Calabrese
- University Joseph Fourier-Grenoble 1, CNRS, TIMC-IMAG Laboratory CNRS UMR 5525, PRETA team, Grenoble, F-38041, France
| | - Raphaël Briot
- University Joseph Fourier-Grenoble 1, CNRS, TIMC-IMAG Laboratory CNRS UMR 5525, PRETA team, Grenoble, F-38041, France
| | - Pierre Baconnier
- University Joseph Fourier-Grenoble 1, CNRS, TIMC-IMAG Laboratory CNRS UMR 5525, PRETA team, Grenoble, F-38041, France
| |
Collapse
|
66
|
Shoaib A, Mabote T, Zuhair M, Kassianides X, Cleland JGF. Acute heart failure (suspected or confirmed): Initial diagnosis and subsequent evaluation with traditional and novel technologies. ACTA ACUST UNITED AC 2013. [DOI: 10.4236/wjcd.2013.33046] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
67
|
Busse L, Davison DL, Junker C, Chawla LS. Hemodynamic monitoring in the critical care environment. Adv Chronic Kidney Dis 2013; 20:21-9. [PMID: 23265593 DOI: 10.1053/j.ackd.2012.10.006] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2012] [Revised: 10/18/2012] [Accepted: 10/19/2012] [Indexed: 12/24/2022]
Abstract
Hemodynamic monitoring is essential to the care of the critically ill patient. In the hemodynamically unstable patient where volume status is not only difficult to determine, but excess fluid administration can lead to adverse consequences, utilizing markers that guide resuscitation can greatly affect outcomes. Several markers and devices have been developed to aid the clinician in assessing volume status with the ultimate goal of optimizing tissue oxygenation and organ perfusion. Early static measures of volume status, including pulmonary artery occlusion pressure and central venous pressure, have largely been replaced by newer dynamic measures that rely on real-time measurements of physiological parameters to calculate volume responsiveness. Technological advances have lead to the creation of invasive and noninvasive devices that guide the physician through the resuscitative process. In this manuscript, we review the physiologic rationale behind hemodynamic monitoring, define the markers of volume status and volume responsiveness, and explore the various devices and technologies available for the bedside clinician.
Collapse
|
68
|
SIEJKO KRZYSZTOFZ, THAKUR PRAMODSINGHH, MAILE KEITH, PATANGAY ABHILASH, OLIVARI MARIATERESA. Feasibility of Heart Sounds Measurements from an Accelerometer within an ICD Pulse Generator. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2012; 36:334-46. [DOI: 10.1111/pace.12059] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/13/2011] [Revised: 09/11/2012] [Accepted: 10/26/2012] [Indexed: 11/30/2022]
Affiliation(s)
| | | | | | - ABHILASH PATANGAY
- Minneapolis Heart Institute at Abbott Northwestern Hospital; Minneapolis; Minnesota
| | - MARIA-TERESA OLIVARI
- Minneapolis Heart Institute at Abbott Northwestern Hospital; Minneapolis; Minnesota
| |
Collapse
|
69
|
Tomsin K, Mesens T, Molenberghs G, Gyselaers W. Impedance cardiography in uncomplicated pregnancy and pre-eclampsia: A reliability study. J OBSTET GYNAECOL 2012; 32:630-4. [DOI: 10.3109/01443615.2012.673036] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
70
|
Abstract
Heart failure is a syndrome in which myocardial function is incapable of providing for normal physiologic needs. In the acute care setting, cardiac dysfunction primarily manifests with volume perturbations and presents with signs and symptoms of vascular congestion. Thus, in acute heart failure volume assessment is crucial in diagnosing and improving the prognosis. Also, goal-directed therapy relies on accurate volume assessment to minimize the adverse outcomes of inappropriate, ineffective, or excessive diuresis. Currently, in most institutions clinical methods of volume assessment are the mainstay. However, these methods are highly dependent on the practitioners' skill level. In fact, there is a high variability between experienced physicians when assessing volume. As adjuncts, objective methods of volume assessment are being developed and used such as natriuretic peptides, bioimpedance analysis, and imaging.
Collapse
|
71
|
Optimizing fluid management in patients with acute decompensated heart failure (ADHF): the emerging role of combined measurement of body hydration status and brain natriuretic peptide (BNP) levels. Heart Fail Rev 2012; 16:519-29. [PMID: 21604179 PMCID: PMC3151484 DOI: 10.1007/s10741-011-9244-4] [Citation(s) in RCA: 57] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
The study tests the hypothesis that in patients admitted with acutely decompensated heart failure (ADHF), achievement of adequate body hydration status with intensive medical therapy, modulated by combined bioelectrical vectorial impedance analysis (BIVA) and B-type natriuretic peptide (BNP) measurement, may contribute to optimize the timing of patient’s discharge and to improve clinical outcomes. Three hundred patients admitted for ADHF underwent serial BIVA and BNP measurement. Therapy was titrated to reach a BNP value of <250 pg/ml, whenever possible. Patients were categorized as early responders (rapid BNP fall below 250 pg/ml); late responders (slow BNP fall below 250 pg/ml, after aggressive therapy); and non-responders (BNP persistently >250 pg/ml). Worsening of renal function (WRF) was evaluated during hospitalization. Death and rehospitalization were monitored with a 6-month follow-up. BNP value on discharge of ≤250 pg/ml led to a 25% event rate within 6 months (Group A: 17.4%; Group B: 21%, Chi2; n.s.), whereas a value >250 pg/ml (Group C) was associated with a far higher percentage (37%). At discharge, body hydration was 73.8 ± 3.2% in the total population and 73.2 ± 2.1, 73.5 ± 2.8, 74.1 ± 3.6% in the three groups, respectively. WRF was observed in 22.3% of the total. WRF occurred in 22% in Group A, 32% in Group B, and 20% in Group C (P = n.s.). Our study confirms the hypothesis that combined BNP/BIVA sequential measurements help to achieve adequate fluid balance status in patients with ADHF and can be used to drive a “tailored therapy,” allowing clinicians to identify high-risk patients and possibly to reduce the incidence of complications secondary to fluid management strategies.
Collapse
|
72
|
Tang WHW, Wickemeyer WJ, Germany RE, Hoppe BL, Andriulli JA, Brady PA, Sarkar S, Hettrick DA, Small RS. Uncovering interim clinical events at the time of clinical encounter by reviewing intrathoracic impedance threshold crossings. J Card Fail 2011; 17:893-8. [PMID: 22041325 DOI: 10.1016/j.cardfail.2011.07.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2010] [Revised: 05/23/2011] [Accepted: 07/14/2011] [Indexed: 11/25/2022]
Abstract
BACKGROUND Acute decreases in intrathoracic impedance monitored by implanted devices have been shown to precede heart failure exacerbations, although there is still debate regarding its clinical utility in predicting and preventing future events. However, the usefulness of such information to direct patient encounter and enhance patient recall of relevant preceding clinical events at the point of care has not been carefully examined. METHODS AND RESULTS In this multicenter study, we interviewed 326 patients with heart failure who received an implanted device with intrathoracic impedance-monitoring capabilities both before and after device information was reviewed. We compared the self-reported clinically relevant events (including heart failure hospitalizations, signs and symptoms of worsening heart failure, changes in diuretic therapy, or other fluid-related events) obtained before and after device interrogation, and then examined the relationship between such events with impedance trends documented by the devices. Over 333 ± 96 days of device monitoring, 215 of 326 patients experienced 590 intrathoracic impedance fluid index threshold-crossing events at the nominal threshold value (60 Ω-d). Review of device-derived information led to the discovery of 221 (37%) previously unreported clinically relevant events in 138 subjects. This included 60 subjects not previously identified as having had clinically relevant events (or 35% of the 171 subjects who did not report events). CONCLUSIONS Our data demonstrated that reviewing device-derived intrathoracic impedance trends at the time of clinical encounter may help uncover self-reporting of potential clinically relevant events.
Collapse
|
73
|
Abstract
Background—
Heart failure is associated with frequent hospitalizations, often resulting from volume overload. Measurement of intrathoracic impedance with an implanted device with an audible patient alert may detect increases in pulmonary fluid retention early. We hypothesized that early intervention could prevent hospitalizations and affect outcome.
Methods and Results—
We studied 335 patients with chronic heart failure who had undergone implantation of an implantable cardioverter-defibrillator alone (18%) or with cardiac resynchronization therapy (82%). All devices featured a monitoring tool to track changes in intrathoracic impedance (OptiVol) and other diagnostic parameters. Patients were randomized to have information available to physicians and patients as an audible alert in case of preset threshold crossings (access arm) or not (control arm). The primary end point was a composite of all-cause mortality and heart failure hospitalizations. During 14.9±5.4 months, this occurred in 48 patients (29%) in the access arm and in 33 patients (20%) in the control arm (
P
=0.063; hazard ratio, 1.52; 95% confidence interval, 0.97–2.37). This was due mainly to more heart failure hospitalizations (hazard ratio, 1.79; 95% confidence interval, 1.08–2.95;
P
=0.022), whereas the number of deaths was comparable (19 versus 15;
P
=0.54). The number of outpatient visits was higher in the access arm (250 versus 84;
P
<0.0001), with relatively more signs of heart failure among control patients during outpatient visits. Although the trial was terminated as a result of slow enrollment, a post hoc futility analysis indicated that a positive result would have been unlikely.
Conclusion—
Use of an implantable diagnostic tool to measure intrathoracic impedance with an audible patient alert did not improve outcome and increased heart failure hospitalizations and outpatient visits in heart failure patients.
Clinical Trial Registration—
URL:
http://www.clinicaltrials.gov
. Unique identifier: NCT 00480077.
Collapse
|
74
|
Kataoka H. Detection of preclinical body fluid retention in established heart failure patients during follow-up by a digital weight scale incorporating a bioelectrical impedance analyzer. ACTA ACUST UNITED AC 2011; 18:37-42. [PMID: 22277176 DOI: 10.1111/j.1751-7133.2011.00230.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
This study examined the characteristics of asymptomatic worsening heart failure (HF) events and validated the role of a novel HF monitoring method (measuring body weight [BW] and percent body fat [BF%]) to identify such worsening HF events. A clinician determined worsening HF status by evaluating symptoms, physical signs, and pleural effusion on ultrasonography. A criterion of significant fluid weight gain was defined as BW gain ≥1.5 kg with a concomitant decrease in BF%. A total of 74 HF patients were included. During a mean follow-up of 20.8 months, 1588 visits were evaluated. A total of 79 worsening HF events occurred in 50 patients, in which worsening was symptomatic in 46 events (58%) and asymptomatic in 33 events (42%). Novel method eliminated 42 of 73 (58%) false-positive indications of worsening HF events based only on the BW criterion (≥1.5 kg) without excluding true worsening HF events. The test characteristics of this method in the diagnosis of overall HF events were sensitivity 65.8% (95% confidence interval [CI], 54.3-76.1), specificity 97.9% (95%, CI 97.1-98.6), positive predictive value 62.7% (95% CI, 51.3-73.0), and negative predictive value 98.2% (95% CI, 97.4-98.8). Preclinical fluid retention occurs frequently in established HF patients, and novel monitoring method can specifically identify preclinical worsening HF.
Collapse
Affiliation(s)
- Hajime Kataoka
- Division of Internal Medicine, Nishida Hospital, Oita, Japan.
| |
Collapse
|
75
|
Brachmann J, Böhm M, Rybak K, Klein G, Butter C, Klemm H, Schomburg R, Siebermair J, Israel C, Sinha AM, Drexler H. Fluid status monitoring with a wireless network to reduce cardiovascular-related hospitalizations and mortality in heart failure: rationale and design of the OptiLink HF Study (Optimization of Heart Failure Management using OptiVol Fluid Status Monitoring and CareLink). Eur J Heart Fail 2011; 13:796-804. [PMID: 21555324 PMCID: PMC3125124 DOI: 10.1093/eurjhf/hfr045] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/11/2023] Open
Abstract
Aims The Optimization of Heart Failure Management using OptiVol Fluid Status Monitoring and CareLink (OptiLink HF) study is designed to investigate whether OptiVol fluid status monitoring with an automatically generated wireless CareAlert notification via the CareLink Network can reduce all-cause death and cardiovascular hospitalizations in an HF population, compared with standard clinical assessment. Methods Patients with newly implanted or replacement cardioverter-defibrillator devices with or without cardiac resynchronization therapy, who have chronic HF in New York Heart Association class II or III and a left ventricular ejection fraction ≤35% will be eligible to participate. Following device implantation, patients are randomized to either OptiVol fluid status monitoring through CareAlert notification or regular care (OptiLink ‘on' vs. ‘off'). The primary endpoint is a composite of all-cause death or cardiovascular hospitalization. It is estimated that 1000 patients will be required to demonstrate superiority of the intervention group to reduce the primary outcome by 30% with 80% power. Conclusion The OptiLink HF study is designed to investigate whether early detection of congestion reduces mortality and cardiovascular hospitalization in patients with chronic HF. The study is expected to close recruitment in September 2012 and to report first results in May 2014. ClinicalTrials.gov Identifier: NCT00769457
Collapse
Affiliation(s)
- Johannes Brachmann
- Department of Cardiology, Angiology and Pneumology, Klinikum Coburg GmbH, II, Medizinische Klinik, Coburg, Germany.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
76
|
|
77
|
Munir MB, Jiang J, Mehdi MJ, Takayama H, Cheema FH. A novel subcutaneous counterpulsation device: acute hemodynamic efficacy during pharmacologically induced hypertension, hypotension, and heart failure. Artif Organs 2011; 35:92-3; author reply 93-5. [PMID: 21226745 DOI: 10.1111/j.1525-1594.2010.01176.x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
78
|
Mansouri S, Mahjoubi H, Ben Salah R. Conception d’un prototype de bio-impédance périphérique autour d’un FPGA Virtex-5 LX30. Ing Rech Biomed 2010. [DOI: 10.1016/j.irbm.2010.10.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
79
|
Branzi G, Malfatto G, Villani A, Ciambellotti F, Revera M, Giglio A, Rosa FD, Facchini M, Parati G. Acute effects of levosimendan on mitral regurgitation and diastolic function in patients with advanced chronic heart failure. J Cardiovasc Med (Hagerstown) 2010; 11:662-8. [DOI: 10.2459/jcm.0b013e32833832f6] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
80
|
Kataoka H. Novel monitoring method for the management of heart failure: combined measurement of body weight and bioimpedance index of body fat percentage. Future Cardiol 2009; 5:541-6. [DOI: 10.2217/fca.09.47] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
Abstract
Although body weight scales are most commonly used to evaluate body fluid status during follow-up of definite heart failure (HF) patients, bioimpedance measurement methods have become increasingly available in the clinical setting. These monitoring methods, however, are typically used separately to evaluate body fluid status in HF patients. Kataoka developed a novel method for monitoring HF patients using a digital weight scale that incorporated a bioelectrical impedance analyzer. This method combines the well-known advantages of body weighing with a refined bioimpedance technique to monitor HF status and provides valid information regarding a change in a patient’s body fluid status during follow-up for HF, such as predominant fluid versus fat weight gain or loss. This special report describes examples of the practical use of this method for monitoring and treating definite HF patients.
Collapse
Affiliation(s)
- Hajime Kataoka
- Division of Internal Medicine, Nishida Hospital, 3–3–24 Ohte-machi, Saiki-city, Oita 876–0831, Japan
| |
Collapse
|
81
|
Tang WHW. Impedance monitoring in heart failure: are we really measuring hemodynamics? Am Heart J 2009; 158:152-3. [PMID: 19619688 DOI: 10.1016/j.ahj.2009.05.032] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2009] [Accepted: 05/26/2009] [Indexed: 11/17/2022]
|
82
|
Torres D, Parrinello G, Paterna S, Di Pasquale P, Torres A, Trapanese C, Licata G. A new option in measuring bioimpedance in congestive heart failure. Am Heart J 2009; 158:e1. [PMID: 19540376 DOI: 10.1016/j.ahj.2009.05.008] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|