51
|
Chansi, Bhardwaj R, Rao RP, Mukherjee I, Agrawal PK, Basu T, Bharadwaj LM. Layered construction of nano immuno-hybrid embedded MOF as an electrochemical sensor for rapid quantification of total pesticides load in vegetable extract. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.114386] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
52
|
Campuzano S, Pedrero M, Gamella M, Serafín V, Yáñez-Sedeño P, Pingarrón JM. Beyond Sensitive and Selective Electrochemical Biosensors: Towards Continuous, Real-Time, Antibiofouling and Calibration-Free Devices. SENSORS (BASEL, SWITZERLAND) 2020; 20:E3376. [PMID: 32560028 PMCID: PMC7348748 DOI: 10.3390/s20123376] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/31/2020] [Revised: 06/12/2020] [Accepted: 06/13/2020] [Indexed: 12/11/2022]
Abstract
Nowadays, electrochemical biosensors are reliable analytical tools to determine a broad range of molecular analytes because of their simplicity, affordable cost, and compatibility with multiplexed and point-of-care strategies. There is an increasing demand to improve their sensitivity and selectivity, but also to provide electrochemical biosensors with important attributes such as near real-time and continuous monitoring in complex or denaturing media, or in vivo with minimal intervention to make them even more attractive and suitable for getting into the real world. Modification of biosensors surfaces with antibiofouling reagents, smart coupling with nanomaterials, and the advances experienced by folded-based biosensors have endowed bioelectroanalytical platforms with one or more of such attributes. With this background in mind, this review aims to give an updated and general overview of these technologies as well as to discuss the remarkable achievements arising from the development of electrochemical biosensors free of reagents, washing, or calibration steps, and/or with antifouling properties and the ability to perform continuous, real-time, and even in vivo operation in nearly autonomous way. The challenges to be faced and the next features that these devices may offer to continue impacting in fields closely related with essential aspects of people's safety and health are also commented upon.
Collapse
Affiliation(s)
- Susana Campuzano
- Departamento de Química Analítica, Facultad de CC. Químicas, Universidad Complutense de Madrid, E-28040 Madrid, Spain; (M.P.); (M.G.); (V.S.); (P.Y.-S.)
| | | | | | | | | | - José Manuel Pingarrón
- Departamento de Química Analítica, Facultad de CC. Químicas, Universidad Complutense de Madrid, E-28040 Madrid, Spain; (M.P.); (M.G.); (V.S.); (P.Y.-S.)
| |
Collapse
|
53
|
Metal-organic framework-based materials as an emerging platform for advanced electrochemical sensing. Coord Chem Rev 2020. [DOI: 10.1016/j.ccr.2020.213222] [Citation(s) in RCA: 216] [Impact Index Per Article: 43.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
54
|
Aghaei M, Sajjadi S, Keihan AH. Sono-coprecipitation synthesis of ZnO/CuO nanophotocatalyst for removal of parathion from wastewater. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2020; 27:11541-11553. [PMID: 31965505 DOI: 10.1007/s11356-020-07680-0] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2019] [Accepted: 01/07/2020] [Indexed: 06/10/2023]
Abstract
Semiconductor photocatalysis is an effective method used to degrade organophosphorus compounds. Here, the potential of a commonly mixed oxide semiconductor, ZnO/CuO, has been examined to degrade methyl parathion. Sono-coprecipitation method was used to provide ZnO/CuO nanocomposites, and it was applied to photocatalytic and sono-photocatalytic degradation of methyl parathion under solar light irradiation. Powder x-ray diffraction (XRD), Fourier-transform infrared spectroscopy (FTIR), the Brunauer-Emmett-Teller (BET) surface area, field emission scanning electron microscopy (FE-SEM), and transmission electron microscopy (TEM) were used to characterize the synthesized samples. The optimal experimental conditions such as ZnO/CuO photocatalyst 90:10 M ratios, the initial concentration of 20 mg/L parathion, 1 g/L photocatalyst loading, no compressed air sparging, pH of 8, and ultrasonic power (60 W and 80 kHz) were used to degrade the parathion effectively. The parathion was fully (100% removal) degraded after 60 min sono-photoirradiation in the optimal experimental conditions. A real water sample was used to examine the ability of the ZnO/CuO photocatalyst 90:10 to remove the parathion in the water-soluble ions. Graphical abstract.
Collapse
Affiliation(s)
- Mohammad Aghaei
- Student Research Committee, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - Sharareh Sajjadi
- Department of Biology, Roudehen Branch, Islamic Azad University, Roudehen, Iran
| | - Amir Homayoun Keihan
- Molecular Biology Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
55
|
An ultrasensitive biosensor for fast detection of Salmonella using 3D magnetic grid separation and urease catalysis. Biosens Bioelectron 2020; 157:112160. [PMID: 32250940 DOI: 10.1016/j.bios.2020.112160] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2019] [Revised: 02/05/2020] [Accepted: 03/17/2020] [Indexed: 12/16/2022]
Abstract
Screening of pathogenic bacteria plays a crucial role in preventing foodborne disease outbreaks. In this study, an ultrasensitive biosensor was developed for fast detection of Salmonella using self-assembled magnetic nanoparticle (MNP) chains for continuous-flow separation of Salmonella from large-volume sample, urease coated gold nanoparticles (GNPs) for specific labelling of Salmonella and efficient amplification of signal, and linear scan voltammetry for sensitive detection of catalysate. First, MNP chains were formed and distributed in a 3D spiral channel using mutually repelling cylindrical magnets and ring iron gears to control anti-Salmonella monoclonal antibody coated MNPs. After bacterial sample was continuous-flow drawn into the channel, bacteria-MNP complexes (magnetic bacteria) were formed on the chains, resulting in specific separation of target bacteria from sample background. Then, anti-Salmonella polyclonal antibodies and urease coated GNPs were drawn to label the magnetic bacteria, resulting in the formation of enzymatic bacteria. After washing to remove residual GNPs, urea was drawn and catalyzed by urease on enzymatic bacteria, resulting in the produce of catalysate (ammonium carbonate). Finally, the catalysate was transferred into a microfluidic chip with a thin-film Ag/AgCl reference electrode array for linear scan voltammetric measurement, and the resistance of catalysate was obtained to determine the amount of target bacteria. This biosensor could quantitatively detect Salmonella from 1.0 × 101 to 1.0 × 106 CFU/mL in 1 h with low detection limit of 101 CFU/mL. The mean recovery for Salmonella in spiked milk was about 104.3%.
Collapse
|
56
|
Liu Y, Hao M, Chen Z, Liu L, Liu Y, Yang W, Ramakrishna S. A review on recent advances in application of electrospun nanofiber materials as biosensors. CURRENT OPINION IN BIOMEDICAL ENGINEERING 2020. [DOI: 10.1016/j.cobme.2020.02.001] [Citation(s) in RCA: 50] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
57
|
Sappia LD, Tuninetti JS, Ceolín M, Knoll W, Rafti M, Azzaroni O. MOF@PEDOT Composite Films for Impedimetric Pesticide Sensors. GLOBAL CHALLENGES (HOBOKEN, NJ) 2020; 4:1900076. [PMID: 32042446 PMCID: PMC7001120 DOI: 10.1002/gch2.201900076] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/27/2019] [Revised: 11/29/2019] [Indexed: 05/05/2023]
Abstract
Due to its deleterious effects on health, development of new methods for detection and removal of pesticide residues in primary and derived agricultural products is a research topic of great importance. Among them, imazalil (IMZ) is a widely used post-harvest fungicide with good performances in general, and is particularly applied to prevent green mold in citrus fruits. In this work, a composite film for the impedimetric sensing of IMZ built from metal-organic framework nanocrystallites homogeneously distributed on a conductive poly(3,4-ethylene dioxythiophene) (PEDOT) layer is presented. The as-synthetized thin films are produced via spin-coating over poly(ethylene terephtalate (PET) substrate following a straightforward, cost-effective, single-step procedure. By means of impedance spectroscopy, electric transport properties of the films are studied, and high sensitivity towards IMZ concentration in the range of 15 ppb to 1 ppm is demonstrated (featuring 1.6 and 4.2 ppb limit of detection, when using signal modulus and phase, respectively). The sensing platform hereby presented could be used for the construction of portable, miniaturized, and ultrasensitive devices, suitable for pesticide detection in food, wastewater effluents, or the assessment of drinking-water quality.
Collapse
Affiliation(s)
- Luciano D. Sappia
- Instituto de Investigaciones Fisicoquímicas Teóricas y AplicadasDepartamento de QuímicaFacultad de Ciencias ExactasUniversidad Nacional de La PlataCONICET, CC 16 Suc. 4La PlataB1904DPIArgentina
| | - Jimena S. Tuninetti
- Instituto de Investigaciones Fisicoquímicas Teóricas y AplicadasDepartamento de QuímicaFacultad de Ciencias ExactasUniversidad Nacional de La PlataCONICET, CC 16 Suc. 4La PlataB1904DPIArgentina
| | - Marcelo Ceolín
- Instituto de Investigaciones Fisicoquímicas Teóricas y AplicadasDepartamento de QuímicaFacultad de Ciencias ExactasUniversidad Nacional de La PlataCONICET, CC 16 Suc. 4La PlataB1904DPIArgentina
| | - Wolfgang Knoll
- CEST – Competence Center for Electrochemical Surface TechnologiesKonrad Lorenz Strasse 243430TullnAustria
- Austrian Institute of TechnologyDonau‐City‐Strasse 11220ViennaAustria
| | - Matías Rafti
- Instituto de Investigaciones Fisicoquímicas Teóricas y AplicadasDepartamento de QuímicaFacultad de Ciencias ExactasUniversidad Nacional de La PlataCONICET, CC 16 Suc. 4La PlataB1904DPIArgentina
| | - Omar Azzaroni
- Instituto de Investigaciones Fisicoquímicas Teóricas y AplicadasDepartamento de QuímicaFacultad de Ciencias ExactasUniversidad Nacional de La PlataCONICET, CC 16 Suc. 4La PlataB1904DPIArgentina
- CEST‐UNLP Partner Lab for BioelectronicsDiagonal 64 y 113La Plata1900Argentina
| |
Collapse
|
58
|
Wu C, Wang S, Luo X, Yuan R, Yang X. Adenosine triphosphate responsive metal-organic frameworks equipped with a DNA structure lock for construction of a ratiometric SERS biosensor. Chem Commun (Camb) 2020; 56:1413-1416. [PMID: 31912820 DOI: 10.1039/c9cc08440a] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
A novel ratiometric surface-enhanced Raman scattering (SERS) biosensor was constructed based on stimuli-responsive DNA functionalized metal organic frameworks (MOFs) for detection of adenosine triphosphate (ATP). As a result, the detection range of ATP was 1 nM to 200 nM with a detection limit of 0.4 nM. The ratiometric SERS biosensor strategy offers a lower detection limit and exhibits a more enhanced performance than the typical SERS detection based on single signal response, which may have potential for detection of other biomolecules or metal ions.
Collapse
Affiliation(s)
- Caijun Wu
- Key Laboratory of Luminescent and Real-Time Analytical Chemistry (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing, P. R. China.
| | - Shufan Wang
- Key Laboratory of Luminescent and Real-Time Analytical Chemistry (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing, P. R. China.
| | - Xiliang Luo
- Shandong Key Laboratory of Biochemical Analysis, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042, P. R. China
| | - Ruo Yuan
- Key Laboratory of Luminescent and Real-Time Analytical Chemistry (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing, P. R. China.
| | - Xia Yang
- Key Laboratory of Luminescent and Real-Time Analytical Chemistry (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing, P. R. China.
| |
Collapse
|
59
|
Zhang Y, Chen X. Nanotechnology and nanomaterial-based no-wash electrochemical biosensors: from design to application. NANOSCALE 2019; 11:19105-19118. [PMID: 31549117 DOI: 10.1039/c9nr05696c] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Nanotechnology and nanomaterial based electrochemical biosensors (ECBs) have achieved great development in many fields, such as clinical diagnosis, food analysis, and environmental monitoring. Nowadays, the single-handed pursuit of sensitivity and accuracy cannot meet the demands of detection in many in situ and point-of-care (POC) circumstances. More and more attention has been focused on simplifying the operation procedure and reducing detection time, and thus no-wash assay has become one of the most effective ways for the continuous development of ECBs. However, there are many challenges to realize no-wash detection in the real analysis, such as redox interferences, multiple impurities, non-conducting protein macromolecules, etc. Furthermore, the complex detection circumstance in different application fields makes the realization of no-wash ECBs more complicated and difficult. Thanks to the updated nanotechnology and nanomaterials, in-depth analysis of the obstacles in the detection process and various methods for fabricating no-wash ECBs, most issues have been largely resolved. In this review, we have systematically analyzed the nanomaterial based design strategy of the state-of-the-art no-wash ECBs in the past few years. Following that, we summarized the challenges in the detection process of no-wash ECBs and their applications in different fields. Finally, based on the summary and analysis in this review, we also evaluated and discussed future prospects from the design to the application of ECBs.
Collapse
Affiliation(s)
- Yong Zhang
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China. and Laboratory of Molecular Imaging and Nanomedicine (LOMIN), National Institute of Biomedical Imaging and Bioengineering (NIBIB), National Institutes of Health (NIH), Bethesda, Maryland 20892, USA.
| | - Xiaoyuan Chen
- Laboratory of Molecular Imaging and Nanomedicine (LOMIN), National Institute of Biomedical Imaging and Bioengineering (NIBIB), National Institutes of Health (NIH), Bethesda, Maryland 20892, USA.
| |
Collapse
|
60
|
Liu R, Wang Y, Li B, Liu B, Ma H, Li D, Dong L, Li F, Chen X, Yin X. VXC-72R/ZrO 2/GCE-Based Electrochemical Sensor for the High-Sensitivity Detection of Methyl Parathion. MATERIALS (BASEL, SWITZERLAND) 2019; 12:E3637. [PMID: 31694200 PMCID: PMC6862283 DOI: 10.3390/ma12213637] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/06/2019] [Revised: 10/31/2019] [Accepted: 11/01/2019] [Indexed: 11/21/2022]
Abstract
In this work, a carbon black (VXC-72R)/zirconia (ZrO2) nanocomposite-modified glassy carbon electrode (GCE) was designed, and a VXC-72R/ZrO2/GCE-based electrochemical sensor was successfully fabricated for the high-sensitivity detection of methyl parathion (MP). Electrochemical measurements showed that the VXC-72R/ZrO2/GCE-based electrochemical sensor could make full use of the respective advantages of the VXC-72R and ZrO2 nanoparticles to enhance the MP determination performance. The VXC-72R nanoparticles had high electrical conductivity and a large surface area, and the ZrO2 nanoparticles possessed a strong affinity to phosphorus groups, which could achieve good organophosphorus adsorption. On the basis of the synergistic effect generated from the interaction between the VXC-72R and ZrO2 nanoparticles, the VXC-72R/ZrO2/GCE-based electrochemical sensor could show excellent trace analysis determination performance. The low detection limit could reach up to 0.053 μM, and there was a linear concentration range of 1 μM to 100 μM. Such a high performance indicates that the VXC-72R/ZrO2/GCE-based electrochemical sensor has potential in numerous foreground applications.
Collapse
Affiliation(s)
- Runqiang Liu
- Postdoctoral Research Base, Henan Institute of Science and Technology, Xinxiang 453003, China
- College of Plant Protections, Henan Agricultural University, Zhengzhou 450002, China
- School of Resources and Environment, Henan Institute of Science and Technology, Xinxiang 453003, China; (Y.W.); (B.L.); (B.L.); (H.M.); (D.L.); (L.D.); (F.L.)
| | - Yashuang Wang
- School of Resources and Environment, Henan Institute of Science and Technology, Xinxiang 453003, China; (Y.W.); (B.L.); (B.L.); (H.M.); (D.L.); (L.D.); (F.L.)
| | - Bo Li
- School of Resources and Environment, Henan Institute of Science and Technology, Xinxiang 453003, China; (Y.W.); (B.L.); (B.L.); (H.M.); (D.L.); (L.D.); (F.L.)
| | - Binbin Liu
- School of Resources and Environment, Henan Institute of Science and Technology, Xinxiang 453003, China; (Y.W.); (B.L.); (B.L.); (H.M.); (D.L.); (L.D.); (F.L.)
| | - Huina Ma
- School of Resources and Environment, Henan Institute of Science and Technology, Xinxiang 453003, China; (Y.W.); (B.L.); (B.L.); (H.M.); (D.L.); (L.D.); (F.L.)
| | - Dongdong Li
- School of Resources and Environment, Henan Institute of Science and Technology, Xinxiang 453003, China; (Y.W.); (B.L.); (B.L.); (H.M.); (D.L.); (L.D.); (F.L.)
| | - Li Dong
- School of Resources and Environment, Henan Institute of Science and Technology, Xinxiang 453003, China; (Y.W.); (B.L.); (B.L.); (H.M.); (D.L.); (L.D.); (F.L.)
| | - Fang Li
- School of Resources and Environment, Henan Institute of Science and Technology, Xinxiang 453003, China; (Y.W.); (B.L.); (B.L.); (H.M.); (D.L.); (L.D.); (F.L.)
| | - Xiling Chen
- School of Resources and Environment, Henan Institute of Science and Technology, Xinxiang 453003, China; (Y.W.); (B.L.); (B.L.); (H.M.); (D.L.); (L.D.); (F.L.)
| | - Xinming Yin
- College of Plant Protections, Henan Agricultural University, Zhengzhou 450002, China
| |
Collapse
|
61
|
Chang S, Ji M, Yan C, Zhang K, Deng Q, Xu J, Zhu C, Li B, Wang J. In-Situ Growth of Au on KTaO 3 Sub-Micron Cubes via Wet Chemical Approach for Enhanced Photodegradation of p-Nitrophenol. MATERIALS 2019; 12:ma12121950. [PMID: 31212932 PMCID: PMC6632096 DOI: 10.3390/ma12121950] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/30/2019] [Revised: 06/11/2019] [Accepted: 06/14/2019] [Indexed: 01/20/2023]
Abstract
KTaO3/Au hetero-nanostructures were synthesized by in-situ reduction of HAuCl4 on the surface of hydrothermally-grown KTaO3 sub-micron cubes. The concentration of Au source was found to be a critical factor in controlling the hetero-nucleation of Au nanoparticles on the surface of KTaO3 sub-micron cubes. Loading of Au particles on KTaO3 nanocrystals enriched KTaO3 additional UV-vis absorption in the visible light region. Both KTaO3 and KTaO3/Au nanocrystals were shown to be active in the photo-degradation of p-nitrophenol, while the loading of Au on KTaO3 clearly improved the photo-degradation efficiency of p-nitrophenol compared to that on bare KTaO3 nanocrystals, probably due to the improved light absorption and charge separation.
Collapse
Affiliation(s)
- Shengding Chang
- Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China.
| | - Muwei Ji
- Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China.
- Institute of Low-dimensional Materials Genome Initiative, College of chemistry and environmental engineering, Shenzhen University, Shenzhen 518060, China.
| | - Changxu Yan
- Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China.
| | - Kai Zhang
- Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China.
| | - Qian Deng
- Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China.
| | - Jian Xu
- Institute of Low-dimensional Materials Genome Initiative, College of chemistry and environmental engineering, Shenzhen University, Shenzhen 518060, China.
| | - Caizhen Zhu
- Institute of Low-dimensional Materials Genome Initiative, College of chemistry and environmental engineering, Shenzhen University, Shenzhen 518060, China.
| | - Bo Li
- Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China.
| | - Jin Wang
- Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China.
| |
Collapse
|
62
|
Pournara AD, Tarlas GD, Papaefstathiou GS, Manos MJ. Chemically modified electrodes with MOFs for the determination of inorganic and organic analytes via voltammetric techniques: a critical review. Inorg Chem Front 2019. [DOI: 10.1039/c9qi00965e] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Current status on MOF-modified electrodes for voltammetric analyses of inorganic/organic species is critically discussed. We provide future research directions and specific criteria that MOFs should satisfy prior to their use as electrode modifiers.
Collapse
Affiliation(s)
- Anastasia D. Pournara
- Laboratory of Inorganic Chemistry
- Department of Chemistry
- University of Ioannina
- 45110 Ioannina
- Greece
| | - Georgios D. Tarlas
- Laboratory of Inorganic Chemistry
- Department of Chemistry
- National and Kapodistrian University of Athens
- Zografou
- Greece
| | - Giannis S. Papaefstathiou
- Laboratory of Inorganic Chemistry
- Department of Chemistry
- National and Kapodistrian University of Athens
- Zografou
- Greece
| | - Manolis J. Manos
- Laboratory of Inorganic Chemistry
- Department of Chemistry
- University of Ioannina
- 45110 Ioannina
- Greece
| |
Collapse
|