51
|
Thorpe CT, Chaudhry S, Lei II, Varone A, Riley GP, Birch HL, Clegg PD, Screen HRC. Tendon overload results in alterations in cell shape and increased markers of inflammation and matrix degradation. Scand J Med Sci Sports 2014; 25:e381-91. [DOI: 10.1111/sms.12333] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/05/2014] [Indexed: 12/22/2022]
Affiliation(s)
- C. T. Thorpe
- Institute of Bioengineering; School of Engineering and Materials Science; Queen Mary University of London; London UK
| | - S. Chaudhry
- Institute of Bioengineering; School of Engineering and Materials Science; Queen Mary University of London; London UK
| | - I. I. Lei
- Institute of Bioengineering; School of Engineering and Materials Science; Queen Mary University of London; London UK
| | - A. Varone
- Institute of Bioengineering; School of Engineering and Materials Science; Queen Mary University of London; London UK
| | - G. P. Riley
- School of Biological Sciences; University of East Anglia; Norwich UK
| | - H. L. Birch
- Institute of Orthopaedics and Musculoskeletal Science; University College London; Stanmore UK
| | - P. D. Clegg
- Department of Musculoskeletal Biology; Institute of Ageing and Chronic Disease; University of Liverpool; Neston UK
| | - H. R. C. Screen
- Institute of Bioengineering; School of Engineering and Materials Science; Queen Mary University of London; London UK
| |
Collapse
|
52
|
Legerlotz K, Dorn J, Richter J, Rausch M, Leupin O. Age-dependent regulation of tendon crimp structure, cell length and gap width with strain. Acta Biomater 2014; 10:4447-55. [PMID: 24907659 DOI: 10.1016/j.actbio.2014.05.029] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2014] [Revised: 05/19/2014] [Accepted: 05/23/2014] [Indexed: 12/13/2022]
Abstract
The black-and-white patterning of tendon fascicles when visualized by light microscopy, also known as crimp, is a well-known feature of fiber-forming collagens. However, not much is known about its development, function and response to strain. The objective of this study is to investigate the interaction of tenocyte and crimp morphology as well as their changes with increasing age and acute strain. In contrast to previous studies, which used indirect measures, such as polarized light, to investigate the crimp structure, this study visualizes internal crimp structure in three dimensions without freezing, sectioning, staining or fixing the tissue, via two-photon imaging of green fluorescent protein expressing cells within mouse tail tendon fascicles. This technique further allows straining of the live tissue while visualizing changes in crimp morphology and cell shape with increasing specimen length. Combining this novel microscopy technique with computational image and data analysis revealed a complex relationship between tenocytes and the extracellular matrix that evolves with increasing age. While the reduction of crimping with strain was observed as expected, most of the crimps were gone at 0-1% strain already. Even relatively low strains of 3% led to pronounced changes in the crimp structure after relaxation, particularly in the young animals, which could not be seen with bright-field imaging. Cell length and gap width increased with strain. However, while the cells were able to return to their original length even after high strains of 6%, the gaps between the cells widened, which may imply modified cell-cell communication after overstretching.
Collapse
|
53
|
Chowdhury B, David AL, Thrasivoulou C, Becker DL, Bader DL, Chowdhury TT. Tensile strain increased COX-2 expression and PGE2 release leading to weakening of the human amniotic membrane. Placenta 2014; 35:1057-64. [PMID: 25280972 DOI: 10.1016/j.placenta.2014.09.006] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/26/2014] [Revised: 07/14/2014] [Accepted: 09/11/2014] [Indexed: 11/25/2022]
Abstract
INTRODUCTION There is evidence that premature rupture of the fetal membrane at term/preterm is a result of stretch and tissue weakening due to enhanced prostaglandin E2 (PGE2) production. However, the effect of tensile strain on inflammatory mediators and the stretch sensitive protein connexin-43 (Cx43) has not been examined. We determined whether the inflammatory environment influenced tissue composition and response of the tissue to tensile strain. METHODS Human amniotic membranes isolated from the cervix (CAM) or placenta regions (PAM) were examined by second harmonic generation to identify collagen orientation and subjected to tensile testing to failure. In separate experiments, specimens were subjected to cyclic tensile strain (2%, 1 Hz) for 24 h. Specimens were examined for Cx43 by immunofluorescence confocal microscopy and expression of COX-2 and Cx43 by RT-qPCR. PGE2, collagen, elastin and glycosaminoglycan (GAG) levels were analysed by biochemical assay. RESULTS Values for tensile strength were significantly higher in PAM than CAM with mechanical parameters dependent on collagen orientation. Gene expression for Cx43 and COX-2 was enhanced by tensile strain leading to increased PGE2 release and GAG levels in PAM and CAM when compared to unstrained controls. In contrast, collagen and elastin content was reduced by tensile strain in PAM and CAM. DISCUSSION Fibre orientation has a significant effect on amniotic strength. Tensile strain increased Cx43/COX-2 expression and PGE2 release resulting in tissue softening mediated by enhanced GAG levels and a reduction in collagen/elastin content. CONCLUSION A combination of inflammatory and mechanical factors may disrupt amniotic membrane biomechanics and matrix composition.
Collapse
Affiliation(s)
- B Chowdhury
- Institute for Women's Health, University College London, 86-96 Chenies Mews, London WC1E 6HX, UK
| | - A L David
- Institute for Women's Health, University College London, 86-96 Chenies Mews, London WC1E 6HX, UK
| | - C Thrasivoulou
- Department of Cell and Developmental Biology, UCL, Gower Street, London WC1E 6BT, UK
| | - D L Becker
- Lee Kong Chian School of Medicine, Nanyang Technological University, 11, Mandalay Road, Singapore
| | - D L Bader
- Institute of Bioengineering, School of Engineering and Material Science, Queen Mary University of London, Mile End Road, London E1 4NS, UK; Faculty of Health Sciences, University of Southampton, Southampton General Hospital, Southampton SO16 6YD, UK
| | - T T Chowdhury
- Institute of Bioengineering, School of Engineering and Material Science, Queen Mary University of London, Mile End Road, London E1 4NS, UK.
| |
Collapse
|
54
|
Hyperuricemic PRP in tendon cells. BIOMED RESEARCH INTERNATIONAL 2014; 2014:926481. [PMID: 25276832 PMCID: PMC4170825 DOI: 10.1155/2014/926481] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/30/2014] [Revised: 07/31/2014] [Accepted: 08/04/2014] [Indexed: 01/03/2023]
Abstract
Platelet-rich plasma (PRP) is injected within tendons to stimulate healing. Metabolic alterations such as the metabolic syndrome, diabetes, or hyperuricemia could hinder the therapeutic effect of PRP. We hypothesise that tendon cells sense high levels of uric acid and this could modify their response to PRP. Tendon cells were treated with allogeneic PRPs for 96 hours. Hyperuricemic PRP did not hinder the proliferative actions of PRP. The gene expression pattern of inflammatory molecules in response to PRP showed absence of IL-1b and COX1 and modest expression of IL6, IL8, COX2, and TGF-b1. IL8 and IL6 proteins were secreted by tendon cells treated with PRP. The synthesis of IL6 and IL8 proteins induced by PRP is decreased significantly in the presence of hyperuricemia (P = 0.017 and P = 0.012, resp.). Concerning extracellular matrix, PRP-treated tendon cells displayed high type-1 collagen, moderate type-3 collagen, decorin, and hyaluronan synthase-2 expression and modest expression of scleraxis. Hyperuricemia modified the expression pattern of extracellular matrix proteins, upregulating COL1 (P = 0.036) and COMP (P = 0.012) and downregulating HAS2 (P = 0.012). Positive correlations between TGF-b1 and type-1 collagen (R = 0.905, P = 0.002) and aggrecan (R = 0.833, P = 0.010) and negative correlations between TGF-b1 and IL6 synthesis (R = -0.857, P = 0.007) and COX2 (R = -0.810, P = 0.015) were found.
Collapse
|
55
|
Shepherd JH, Riley GP, Screen HRC. Early stage fatigue damage occurs in bovine tendon fascicles in the absence of changes in mechanics at either the gross or micro-structural level. J Mech Behav Biomed Mater 2014; 38:163-72. [PMID: 25001495 PMCID: PMC4148183 DOI: 10.1016/j.jmbbm.2014.06.005] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2014] [Revised: 06/01/2014] [Accepted: 06/04/2014] [Indexed: 12/04/2022]
Abstract
Many tendon injuries are believed to result from repetitive motion or overuse, leading to the accumulation of micro-damage over time. In vitro fatigue loading can be used to characterise damage during repeated use and investigate how this may relate to the aetiology of tendinopathy. This study considered the effect of fatigue loading on fascicles from two functionally distinct bovine tendons: the digital extensor and deep digital flexor. Micro-scale extension mechanisms were investigated in fascicles before or after a period of cyclic creep loading, comparing two different measurement techniques – the displacement of a photo-bleached grid and the use of nuclei as fiducial markers. Whilst visual damage was clearly identified after only 300 cycles of creep loading, these visual changes did not affect either gross fascicle mechanics or fascicle microstructural extension mechanisms over the 900 fatigue cycles investigated. However, significantly greater fibre sliding was measured when observing grid deformation rather than the analysis of nuclei movement. Measurement of microstructural extension with both techniques was localised and this may explain the absence of change in microstructural deformation in response to fatigue loading. Alternatively, the data may demonstrate that fascicles can withstand a degree of matrix disruption with no impact on mechanics. Whilst use of a photo-bleached grid to directly measure the collagen is the best indicator of matrix deformation, nuclei tracking may provide a better measure of the strain perceived directly by the cells. Tendon fascicle gross mechanics and micro-scale deformation investigated after fatigue loading. Fascicles can withstand a degree of matrix disruption without impact on mechanics. More fibre sliding was observed measuring grid deformation than tracking nuclei. Nuclei tracking may better represent the strains experienced by cells than grid deformation.
Collapse
Affiliation(s)
- Jennifer H Shepherd
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary, University of London, Mile End Road, E1 4NS, UK
| | - Graham P Riley
- School of Biological Sciences, University of East Anglia, UK
| | - Hazel R C Screen
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary, University of London, Mile End Road, E1 4NS, UK.
| |
Collapse
|
56
|
Thorpe CT, Riley GP, Birch HL, Clegg PD, Screen HR. Effect of fatigue loading on structure and functional behaviour of fascicles from energy-storing tendons. Acta Biomater 2014; 10:3217-24. [PMID: 24747261 DOI: 10.1016/j.actbio.2014.04.008] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2013] [Revised: 03/07/2014] [Accepted: 04/08/2014] [Indexed: 11/26/2022]
Abstract
Tendons can broadly be categorized according to their function: those that act purely to position the limb and those that have an additional function as energy stores. Energy-storing tendons undergo many cycles of large deformations during locomotion, and so must be able to extend and recoil efficiently, rapidly and repeatedly. Our previous work has shown rotation in response to applied strain in fascicles from energy-storing tendons, indicating the presence of helical substructures which may provide greater elasticity and recovery. In the current study, we assessed how preconditioning and fatigue loading affect the ability of fascicles from the energy-storing equine superficial digital flexor tendon to extend and recoil. We hypothesized that preconditioned samples would exhibit changes in microstructural strain response, but would retain their ability to recover. We further hypothesized that fatigue loading would result in sample damage, causing further alterations in extension mechanisms and a significant reduction in sample recovery. The results broadly support these hypotheses: preconditioned samples showed some alterations in microstructural strain response, but were able to recover following the removal of load. However, fatigue loaded samples showed visual evidence of damage and exhibited further alterations in extension mechanisms, characterized by decreased rotation in response to applied strain. This was accompanied by increased hysteresis and decreased recovery. These results suggest that fatigue loading results in a compromised helix substructure, reducing the ability of energy-storing tendons to recoil. A decreased ability to recoil may lead to an impaired response to further loading, potentially increasing the likelihood of injury.
Collapse
|
57
|
Design and validation of an in vitro loading system for the combined application of cyclic compression and shear to 3D chondrocytes-seeded agarose constructs. Med Eng Phys 2014; 36:534-40. [DOI: 10.1016/j.medengphy.2013.11.007] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2013] [Revised: 11/04/2013] [Accepted: 11/10/2013] [Indexed: 11/22/2022]
|
58
|
Thorpe CT, Riley GP, Birch HL, Clegg PD, Screen HRC. Fascicles from energy-storing tendons show an age-specific response to cyclic fatigue loading. J R Soc Interface 2014; 11:20131058. [PMID: 24402919 DOI: 10.1098/rsif.2013.1058] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Some tendons, such as the human Achilles and equine superficial digital flexor tendon (SDFT), act as energy stores, stretching and recoiling to increase efficiency during locomotion. Our previous observations of rotation in response to applied strain in SDFT fascicles suggest a helical structure, which may provide energy-storing tendons with a greater ability to extend and recoil efficiently. Despite this specialization, energy-storing tendons are prone to age-related tendinopathy. The aim of this study was to assess the effect of cyclic fatigue loading (FL) on the microstructural strain response of SDFT fascicles from young and old horses. The data demonstrate two independent age-related mechanisms of fatigue failure; in young horses, FL caused low levels of matrix damage and decreased rotation. This suggests that loading causes alterations to the helix substructure, which may reduce their ability to recoil and recover. By contrast, fascicles from old horses, in which the helix is already compromised, showed greater evidence of matrix damage and suffer increased fibre sliding after FL, which may partially explain the age-related increase in tendinopathy. Elucidation of helix structure and the precise alterations occurring owing to both ageing and FL will help to develop appropriate preventative and repair strategies for tendinopathy.
Collapse
Affiliation(s)
- Chavaunne T Thorpe
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, , Mile End Road, London E1 4NS, UK
| | | | | | | | | |
Collapse
|
59
|
Shepherd JH, Legerlotz K, Demirci T, Klemt C, Riley GP, Screen HRC. Functionally distinct tendon fascicles exhibit different creep and stress relaxation behaviour. Proc Inst Mech Eng H 2013; 228:49-59. [PMID: 24285289 PMCID: PMC4361498 DOI: 10.1177/0954411913509977] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Most overuse tendinopathies are thought to be associated with repeated microstrain below the failure threshold, analogous to the fatigue failure that affects materials placed under repetitive loading. Investigating the progression of fatigue damage within tendons is therefore of critical importance. There are obvious challenges associated with the sourcing of human tendon samples for in vitro analysis so animal models are regularly adopted. However, data indicates that fatigue life varies significantly between tendons of different species and with different stresses in life. Positional tendons such as rat tail tendon or the bovine digital extensor are commonly applied in in vitro studies of tendon overuse, but there is no evidence to suggest their behaviour is indicative of the types of human tendon particularly prone to overuse injuries. In this study, the fatigue response of the largely positional digital extensor and the more energy storing deep digital flexor tendon of the bovine hoof were compared to the semitendinosus tendon of the human hamstring. Fascicles from each tendon type were subjected to either stress or strain controlled fatigue loading (cyclic creep or cyclic stress relaxation respectively). Gross fascicle mechanics were monitored after cyclic stress relaxation and the mean number of cycles to failure investigated with creep loading. Bovine extensor fascicles demonstrated the poorest fatigue response, while the energy storing human semitendinosus was the most fatigue resistant. Despite the superior fatigue response of the energy storing tendons, confocal imaging suggested a similar degree of damage in all three tendon types; it appears the more energy storing tendons are better able to withstand damage without detriment to mechanics.
Collapse
Affiliation(s)
- Jennifer H Shepherd
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary, University of London, London, UK
| | | | | | | | | | | |
Collapse
|
60
|
Biomechanical and structural response of healing Achilles tendon to fatigue loading following acute injury. J Biomech 2013; 47:2028-34. [PMID: 24280564 DOI: 10.1016/j.jbiomech.2013.10.054] [Citation(s) in RCA: 55] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2013] [Revised: 10/06/2013] [Accepted: 10/28/2013] [Indexed: 12/16/2022]
Abstract
Achilles tendon injuries affect both athletes and the general population, and their incidence is rising. In particular, the Achilles tendon is subject to dynamic loading at or near failure loads during activity, and fatigue induced damage is likely a contributing factor to ultimate tendon failure. Unfortunately, little is known about how injured Achilles tendons respond mechanically and structurally to fatigue loading during healing. Knowledge of these properties remains critical to best evaluate tendon damage induction and the ability of the tendon to maintain mechanical properties with repeated loading. Thus, this study investigated the mechanical and structural changes in healing mouse Achilles tendons during fatigue loading. Twenty four mice received bilateral full thickness, partial width excisional injuries to their Achilles tendons (IACUC approved) and twelve tendons from six uninjured mice were used as controls. Tendons were fatigue loaded to assess mechanical and structural properties simultaneously after 0, 1, 3, and 6 weeks of healing using an integrated polarized light system. Results showed that the number of cycles to failure decreased dramatically (37-fold, p<0.005) due to injury, but increased throughout healing, ultimately recovering after 6 weeks. The tangent stiffness, hysteresis, and dynamic modulus did not improve with healing (p<0.005). Linear regression analysis was used to determine relationships between mechanical and structural properties. Of tendon structural properties, the apparent birefringence was able to best predict dynamic modulus (R(2)=0.88-0.92) throughout healing and fatigue life. This study reinforces the concept that fatigue loading is a sensitive metric to assess tendon healing and demonstrates potential structural metrics to predict mechanical properties.
Collapse
|
61
|
Kjaer M, Bayer ML, Eliasson P, Heinemeier KM. What is the impact of inflammation on the critical interplay between mechanical signaling and biochemical changes in tendon matrix? J Appl Physiol (1985) 2013; 115:879-83. [DOI: 10.1152/japplphysiol.00120.2013] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023] Open
Abstract
Mechanical loading can influence tendon collagen homeostasis in animal models, while the dynamics of the human adult tendon core tissue are more debatable. Currently available data indicate that human tendon adaptation to loading may happen primarily in the outer tendon region. A role of inflammation in this peritendinous adaptation is supported by a rise in inflammatory mediators in the peritendinous area after physiological mechanical loading in humans. This plays a role in the exercise-induced rise in tendon blood flow and peritendinous collagen synthesis. Although inflammatory activity can activate proteolytic pathways in tendon, mechanical loading can protect against matrix degradation. Acute tendon injury displays an early inflammatory response that seems to be lowered when mechanical loading is applied during regeneration of tendon. Chronically overloaded tendons (tendinopathy) do neither at rest nor after acute exercise display any enhanced inflammatory activity, and thus the basis for using anti-inflammatory medication to treat tendon overuse seems limited.
Collapse
Affiliation(s)
- Michael Kjaer
- Institute of Sports Medicine, Bispebjerg Hospital and Centre of Healthy Aging, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Monika L. Bayer
- Institute of Sports Medicine, Bispebjerg Hospital and Centre of Healthy Aging, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Pernilla Eliasson
- Institute of Sports Medicine, Bispebjerg Hospital and Centre of Healthy Aging, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Katja M. Heinemeier
- Institute of Sports Medicine, Bispebjerg Hospital and Centre of Healthy Aging, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
62
|
Shepherd JH, Screen HRC. Fatigue loading of tendon. Int J Exp Pathol 2013; 94:260-70. [PMID: 23837793 DOI: 10.1111/iep.12037] [Citation(s) in RCA: 61] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2013] [Accepted: 06/12/2013] [Indexed: 12/28/2022] Open
Abstract
Tendon injuries, often called tendinopathies, are debilitating and painful conditions, generally considered to develop as a result of tendon overuse. The aetiology of tendinopathy remains poorly understood, and whilst tendon biopsies have provided some information concerning tendon appearance in late-stage disease, there is still little information concerning the mechanical and cellular events associated with disease initiation and progression. Investigating this in situ is challenging, and numerous models have been developed to investigate how overuse may generate tendon fatigue damage and how this may relate to tendinopathy conditions. This article aims to review these models and our current understanding of tendon fatigue damage. We review the strengths and limitations of different methodologies for characterizing tendon fatigue, considering in vitro methods that adopt both viable and non-viable samples, as well as the range of different in vivo approaches. By comparing data across model systems, we review the current understanding of fatigue damage development. Additionally, we compare these findings with data from tendinopathic tissue biopsies to provide some insights into how these models may relate to the aetiology of tendinopathy. Fatigue-induced damage consistently highlights the same microstructural, biological and mechanical changes to the tendon across all model systems and also correlates well with the findings from tendinopathic biopsy tissue. The multiple testing routes support matrix damage as an important contributor to tendinopathic conditions, but cellular responses to fatigue appear complex and often contradictory.
Collapse
Affiliation(s)
- Jennifer H Shepherd
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary, University of London, London E1 4NS, UK.
| | | |
Collapse
|
63
|
Helical sub-structures in energy-storing tendons provide a possible mechanism for efficient energy storage and return. Acta Biomater 2013; 9:7948-56. [PMID: 23669621 DOI: 10.1016/j.actbio.2013.05.004] [Citation(s) in RCA: 96] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2013] [Revised: 04/18/2013] [Accepted: 05/02/2013] [Indexed: 12/26/2022]
Abstract
The predominant function of tendons is to position the limb during locomotion. Specific tendons also act as energy stores. Energy-storing (ES) tendons are prone to injury, the incidence of which increases with age. This is likely related to their function; ES tendons are exposed to higher strains and require a greater ability to recoil than positional tendons. The specialized properties of ES tendons are thought to be achieved through structural and compositional differences. However, little is known about structure-function relationships in tendons. This study uses fascicles from the equine superficial digital flexor (SDFT) and common digital extensor (CDET) as examples of ES and positional tendons. We hypothesized that extension and recoil behaviour at the micro-level would differ between tendon types, and would alter with age in the injury-prone SDFT. Supporting this, the results show that extension in the CDET is dominated by fibre sliding. By contrast, greater rotation was observed in the SDFT, suggesting a helical component to fascicles in this tendon. This was accompanied by greater recovery and less hysteresis loss in SDFT samples. In samples from aged SDFTs, the amount of rotation and the ability to recover decreased, while hysteresis loss increased. These findings indicate that fascicles in the ES SDFT may have a helical structure, enabling the more efficient recoil observed. Further, the helix structure appears to alter with ageing; this coincides with a reduction in the ability of SDFT fascicles to recoil. This may affect tendon fatigue resistance and predispose aged tendons to injury.
Collapse
|
64
|
Gump BS, McMullan DR, Cauthon DJ, Whitt JA, Del Mundo JD, Letham T, Kim PJ, Friedlander GN, Pingel J, Langberg H, Carroll CC. Short-term acetaminophen consumption enhances the exercise-induced increase in Achilles peritendinous IL-6 in humans. J Appl Physiol (1985) 2013; 115:929-36. [PMID: 23743397 DOI: 10.1152/japplphysiol.00219.2013] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Through an unknown mechanism, the cyclooxygenase inhibitor and antipyretic acetaminophen (APAP) alters tendon mechanical properties in humans when consumed during exercise. Interleukin-6 (IL-6) is produced by tendon during exercise and is a potent stimulator of collagen synthesis. In nontendon tissue, IL-6 is upregulated in the presence of cyclooxygenase inhibitors and may contribute to alterations in extracellular matrix turnover, possibly due to inhibition of prostaglandin E2 (PGE2). We evaluated the effects of APAP on IL-6 and PGE2 in human Achilles peritendinous tissue after 1 h of treadmill exercise. Subjects were randomly assigned to a placebo (n = 8, 26 ± 1 yr) or APAP (n = 8, 25 ± 1 yr) group. Each subject completed a nonexercise and exercise experiment consisting of 6 h of microdialysis. Drug (APAP, 1,000 mg) or placebo was administered in a double-blind manner during both experiments. PGE2 and IL-6 were determined via enzyme immunoassay and APAP via high-performance liquid chromatography. In subjects given APAP, peritendinous APAP levels increased to 4.08 ± 0.65 μg/ml (P < 0.05). PGE2 did not increase with exercise in either group (P > 0.05), nor was PGE2 significantly reduced in the APAP group. IL-6 levels increased with exercise in both groups (P < 0.05), but this increase was greater in the APAP group (P < 0.05). Our findings suggest that APAP enhances tendon IL-6 production after exercise. Peak levels of APAP obtained in the peritendinous space were twofold lower than values reported in plasma or skeletal muscle. These findings provide insight into the effects of APAP on tendon and provide novel information on the kinetics of APAP in tendon tissue after oral APAP consumption.
Collapse
Affiliation(s)
- Brian S Gump
- 1Department of Physiology, Arizona College of Osteopathic Medicine, Midwestern University, Glendale, Arizona
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
65
|
Legerlotz K, Riley GP, Screen HR. GAG depletion increases the stress-relaxation response of tendon fascicles, but does not influence recovery. Acta Biomater 2013; 9:6860-6. [PMID: 23462553 PMCID: PMC3666056 DOI: 10.1016/j.actbio.2013.02.028] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2012] [Revised: 02/06/2013] [Accepted: 02/08/2013] [Indexed: 11/28/2022]
Abstract
Cyclic and static loading regimes are commonly used to study tenocyte metabolism in vitro and to improve our understanding of exercise-associated tendon pathologies. The aims of our study were to investigate if cyclic and static stress relaxation affected the mechanical properties of tendon fascicles differently, if this effect was reversible after a recovery period, and if the removal of glycosaminoglycans (GAGs) affected sample recovery. Tendon fascicles were dissected frombovine-foot extensors and subjected to 14% cyclic (1Hz) or static tensile strain for 30min. Additional fascicles were incubated overnight in buffer with 0.5U chondroitinase ABC or in buffer alone prior to the static stress-relaxation regime. To assess the effect of different stress-relaxation regimes, a quasi-static test to failure was carried out, either directly post loading or after a 2h recovery period, and compared with unloaded control fascicles. Both stress-relaxation regimes led to a significant reduction in fascicle failure stress and strain, but this was more pronounced in the cyclically loaded specimens. Removal of GAGs led to more stress relaxation and greater reductions in failure stress after static loading compared to controls. The reduction in mechanical properties was partially reversible in all samples, given a recovery period of 2h. This has implications for mechanical testing protocols, as a time delay between fatiguing specimens and characterization of mechanical properties will affect the results. GAGs appear to protect tendon fascicles from fatigue effects, possibly by enabling sample hydration.
Collapse
Affiliation(s)
- Kirsten Legerlotz
- School of Biological Sciences, University of East Anglia, Norwich Research Park, Norwich, UK
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, UK
- Corresponding author. Address: School of Biological Sciences, University of East Anglia, Norwich Research Park, Norwich NR4 7TJ, UK. Tel.: +44 1603 591785; fax: +44 1603 592250. k.s.l.@gmx.de
| | - Graham P. Riley
- School of Biological Sciences, University of East Anglia, Norwich Research Park, Norwich, UK
| | - Hazel R.C. Screen
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, UK
| |
Collapse
|
66
|
Dean BJF, Franklin SL, Carr AJ. A systematic review of the histological and molecular changes in rotator cuff disease. Bone Joint Res 2012; 1:158-66. [PMID: 23610686 PMCID: PMC3626275 DOI: 10.1302/2046-3758.17.2000115] [Citation(s) in RCA: 67] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/12/2012] [Accepted: 05/30/2012] [Indexed: 12/16/2022] Open
Abstract
INTRODUCTION The pathogenesis of rotator cuff disease (RCD) is complex and not fully understood. This systematic review set out to summarise the histological and molecular changes that occur throughout the spectrum of RCD. METHODS We conducted a systematic review of the scientific literature with specific inclusion and exclusion criteria. RESULTS A total of 101 studies met the inclusion criteria: 92 studies used human subjects exclusively, seven used animal overuse models, and the remaining two studies involved both humans and an animal overuse model. A total of 58 studies analysed supraspinatus tendon exclusively, 16 analysed subacromial bursal tissue exclusively, while the other studies analysed other tissue or varying combinations of tissue types including joint fluid and muscle. The molecular biomarkers that were altered in RCD included matrix substances, growth factors, enzymes and other proteins including certain neuropeptides. CONCLUSIONS The pathogenesis of RCD is being slowly unravelled as a result of the significant recent advances in molecular medicine. Future research aimed at further unlocking these key molecular processes will be pivotal in developing new surgical interventions both in terms of the diagnosis and treatment of RCD.
Collapse
Affiliation(s)
- B J F Dean
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences (NDORMS), Botnar Research Centre, Institute of Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD, UK
| | | | | |
Collapse
|