51
|
A low-cost small-size commercial PIN photodiode: II. Comparison of measurements with monoenergetic electrons to analytical expressions and Monte Carlo simulations. Radiat Phys Chem Oxf Engl 1993 2021. [DOI: 10.1016/j.radphyschem.2020.109102] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
52
|
Mendes BM, Guimarães Antunes PC, Soares Lopes Branco I, Nascimento ED, Seniwal B, Ferreira Fonseca TC, Yoriyaz H. Calculation of dose point kernel values for monoenergetic electrons and beta emitting radionuclides: Intercomparison of Monte Carlo codes. Radiat Phys Chem Oxf Engl 1993 2021. [DOI: 10.1016/j.radphyschem.2020.109327] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
53
|
Validation of the MC-GPU Monte Carlo code against the PENELOPE/penEasy code system and benchmarking against experimental conditions for typical radiation qualities and setups in interventional radiology and cardiology. Phys Med 2021; 82:64-71. [PMID: 33588229 DOI: 10.1016/j.ejmp.2021.01.075] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Revised: 01/20/2021] [Accepted: 01/24/2021] [Indexed: 11/23/2022] Open
Abstract
INTRODUCTION Interventional procedures are associated with potentially high radiation doses to the skin. The 2013/59/EURATOM Directive establishes that the equipment used for interventional radiology must have a device or a feature informing the practitioner of relevant parameters for assessing patient dose at the end of the procedure. Monte Carlo codes of radiation transport are considered to be one of the most reliable tools available to assess doses. However, they are usually too time consuming for use in clinical practice. This work presents the validation of the fast Monte Carlo code MC-GPU for application in interventional radiology. METHODOLOGIES MC-GPU calculations were compared against the well-validated Monte Carlo simulation code PENELOPE/penEasy by simulating the organ dose distribution in a voxelized anthropomorphic phantom. In a second phase, the code was compared against thermoluminescent measurements performed on slab phantoms, both in a calibration laboratory and at a hospital. RESULTS The results obtained from the two simulation codes show very good agreement, differences in the output were within 1%, whereas the calculation time on the MC-GPU was 2500 times shorter. Comparison with measurements is of the order of 10%, within the associated uncertainty. CONCLUSIONS It has been verified that MC-GPU provides good estimates of the dose when compared to PENELOPE program. It is also shown that it presents very good performance when assessing organ doses in very short times, less than one minute, in real clinical set-ups. Future steps would be to simulate complex procedures with several projections.
Collapse
|
54
|
Aamri H, Fielding A, Aamry A, Sulieman A, Tamam N, Alkhorayef M, Bradley DA. Comparison between PRIMO and EGSnrc Monte Carlo models of the Varian True Beam linear accelerator. Radiat Phys Chem Oxf Engl 1993 2021. [DOI: 10.1016/j.radphyschem.2020.109013] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
55
|
Rodríguez Pérez S, Coolen J, Marshall NW, Cockmartin L, Biebaû C, Desmet J, De Wever W, Struelens L, Bosmans H. Methodology to create 3D models of COVID-19 pathologies for virtual clinical trials. J Med Imaging (Bellingham) 2021; 8:013501. [PMID: 33447646 PMCID: PMC7791575 DOI: 10.1117/1.jmi.8.s1.013501] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2020] [Accepted: 12/11/2020] [Indexed: 12/24/2022] Open
Abstract
Purpose: We describe the creation of computational models of lung pathologies indicative of COVID-19 disease. The models are intended for use in virtual clinical trials (VCT) for task-specific optimization of chest x-ray (CXR) imaging. Approach: Images of COVID-19 patients confirmed by computed tomography were used to segment areas of increased attenuation in the lungs, all compatible with ground glass opacities and consolidations. Using a modeling methodology, the segmented pathologies were converted to polygonal meshes and adapted to fit the lungs of a previously developed polygonal mesh thorax phantom. The models were then voxelized with a resolution of 0.5 × 0.5 × 0.5 mm 3 and used as input in a simulation framework to generate radiographic images. Primary projections were generated via ray tracing while the Monte Carlo transport code was used for the scattered radiation. Realistic sharpness and noise characteristics were also simulated, followed by clinical image processing. Example images generated at 120 kVp were used for the validation of the models in a reader study. Additionally, images were uploaded to an Artificial Intelligence (AI) software for the detection of COVID-19. Results: Nine models of COVID-19 associated pathologies were created, covering a range of disease severity. The realism of the models was confirmed by experienced radiologists and by dedicated AI software. Conclusions: A methodology has been developed for the rapid generation of realistic 3D models of a large range of COVID-19 pathologies. The modeling framework can be used as the basis for VCTs for testing detection and triaging of COVID-19 suspected cases.
Collapse
Affiliation(s)
- Sunay Rodríguez Pérez
- KU Leuven, Medical Physics and Quality Assessment, Leuven, Belgium
- SCK CEN, Radiation Protection Dosimetry and Calibration, Mol, Belgium
| | - Johan Coolen
- KU Leuven, Medical Physics and Quality Assessment, Leuven, Belgium
- UZ Gasthuisberg, Department of Radiology, Leuven, Belgium
| | - Nicholas W. Marshall
- KU Leuven, Medical Physics and Quality Assessment, Leuven, Belgium
- UZ Gasthuisberg, Department of Radiology, Leuven, Belgium
| | | | | | - Jeroen Desmet
- UZ Gasthuisberg, Department of Radiology, Leuven, Belgium
| | - Walter De Wever
- KU Leuven, Medical Physics and Quality Assessment, Leuven, Belgium
- UZ Gasthuisberg, Department of Radiology, Leuven, Belgium
| | - Lara Struelens
- SCK CEN, Radiation Protection Dosimetry and Calibration, Mol, Belgium
| | - Hilde Bosmans
- KU Leuven, Medical Physics and Quality Assessment, Leuven, Belgium
- UZ Gasthuisberg, Department of Radiology, Leuven, Belgium
| |
Collapse
|
56
|
Herraiz JL, Bembibre A, López-Montes A. Deep-Learning Based Positron Range Correction of PET Images. APPLIED SCIENCES-BASEL 2020. [DOI: https://doi.org/10.3390/app11010266] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Positron emission tomography (PET) is a molecular imaging technique that provides a 3D image of functional processes in the body in vivo. Some of the radionuclides proposed for PET imaging emit high-energy positrons, which travel some distance before they annihilate (positron range), creating significant blurring in the reconstructed images. Their large positron range compromises the achievable spatial resolution of the system, which is more significant when using high-resolution scanners designed for the imaging of small animals. In this work, we trained a deep neural network named Deep-PRC to correct PET images for positron range effects. Deep-PRC was trained with modeled cases using a realistic Monte Carlo simulation tool that considers the positron energy distribution and the materials and tissues it propagates into. Quantification of the reconstructed PET images corrected with Deep-PRC showed that it was able to restore the images by up to 95% without any significant noise increase. The proposed method, which is accessible via Github, can provide an accurate positron range correction in a few seconds for a typical PET acquisition.
Collapse
|
57
|
Herraiz JL, Bembibre A, López-Montes A. Deep-Learning Based Positron Range Correction of PET Images. APPLIED SCIENCES 2020; 11:266. [DOI: 10.3390/app11010266] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Positron emission tomography (PET) is a molecular imaging technique that provides a 3D image of functional processes in the body in vivo. Some of the radionuclides proposed for PET imaging emit high-energy positrons, which travel some distance before they annihilate (positron range), creating significant blurring in the reconstructed images. Their large positron range compromises the achievable spatial resolution of the system, which is more significant when using high-resolution scanners designed for the imaging of small animals. In this work, we trained a deep neural network named Deep-PRC to correct PET images for positron range effects. Deep-PRC was trained with modeled cases using a realistic Monte Carlo simulation tool that considers the positron energy distribution and the materials and tissues it propagates into. Quantification of the reconstructed PET images corrected with Deep-PRC showed that it was able to restore the images by up to 95% without any significant noise increase. The proposed method, which is accessible via Github, can provide an accurate positron range correction in a few seconds for a typical PET acquisition.
Collapse
Affiliation(s)
- Joaquín L. Herraiz
- Nuclear Physics Group and IPARCOS, Faculty of Physical Sciences, University Complutense of Madrid, CEI Moncloa, 28040 Madrid, Spain
- Health Research Institute of the Hospital Clínico San Carlos (IdISSC), 28040 Madrid, Spain
| | - Adrián Bembibre
- Nuclear Physics Group and IPARCOS, Faculty of Physical Sciences, University Complutense of Madrid, CEI Moncloa, 28040 Madrid, Spain
| | - Alejandro López-Montes
- Nuclear Physics Group and IPARCOS, Faculty of Physical Sciences, University Complutense of Madrid, CEI Moncloa, 28040 Madrid, Spain
| |
Collapse
|
58
|
Czarnecki D, Zink K, Pimpinella M, Borbinha J, Teles P, Pinto M. Monte Carlo calculation of quality correction factors based on air kerma and absorbed dose to water in medium energy x-ray beams. Phys Med Biol 2020; 65:245042. [PMID: 33120372 DOI: 10.1088/1361-6560/abc5c9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Clinical dosimetry is typically performed using ion chambers calibrated in terms of absorbed dose to water. As primary measurement standards for this quantity for low and medium energy x-rays are available only since a few years, most dosimetry protocols for this photon energy range are still based on air kerma calibration. For that reason, data for beam quality correction factors [Formula: see text], necessary for the application of dose to water based protocols, are scarce in literature. Currently the international IAEA TRS-398 Code of Practice is under revision and new [Formula: see text] factors for a large number of ion chambers will be introduced in the update of this protocol. Several international groups provided the IAEA with experimental and Monte Carlo based data for this revision. Within the European Community the EURAMET 16NRM03 RTNORM project was initiated for that purpose. In the present study, Monte Carlo based results for the beam quality correction factors in medium energy x-ray beams for six ion chambers applying different Monte Carlo codes are presented. Additionally, the perturbation factor p Q , necessary for the calculation of dose to water from an air kerma calibration coefficient, was determined. The beam quality correction factor [Formula: see text] for the chambers varied in the investigated energy range by about 4%-5%, and for five out of six chambers the data could be fitted by a simple logarithmic function, if the half-value-layer was used as the beam quality specifier. Corresponding data using different Monte Carlo codes for the same ion chamber agreed within 0.5%. For the perturbation factor p Q , the data did not obey a comparable simple relationship with the beam quality specifier. The variation of p Q for all ion chambers was in the range of 3%-4%. Compared to recently published data, our p Q data is around 1% larger, although the same Monte Carlo code has been used. Compared to the latest experimental data, there are even deviations in the range of 2%.
Collapse
Affiliation(s)
- Damian Czarnecki
- Institute of Medical Physics and Radiation Protection, University of Applied Sciences Giessen (THM), Giessen, Germany
| | | | | | | | | | | |
Collapse
|
59
|
Valdes-Cortez C, Ballester F, Vijande J, Gimenez V, Gimenez-Alventosa V, Perez-Calatayud J, Niatsetski Y, Andreo P. Depth-dose measurement corrections for the surface electronic brachytherapy beams of an Esteya ® unit: a Monte Carlo study. Phys Med Biol 2020; 65. [DOI: 10.1088/1361-6560/ab9773] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2020] [Accepted: 05/28/2020] [Indexed: 11/12/2022]
Abstract
Abstract
Three different correction factors for measurements with the parallel-plate ionization chamber PTW T34013 on the Esteya electronic brachytherapy unit have been investigated. This chamber type is recommended by AAPM TG-253 for depth-dose measurements in the 69.5 kV x-ray beam generated by the Esteya unit.
Monte Carlo simulations using the PENELOPE-2018 system were performed to determine the absorbed dose deposited in water and in the chamber sensitive volume at different depths with a Type A uncertainty smaller than 0.1%. Chamber-to-chamber differences have been explored performing measurements using three different chambers. The range of conical applicators available, from 10 to 30 mm in diameter, has been explored.
Using a depth-independent global chamber perturbation correction factor without a shift of the effective point of measurement yielded differences between the absorbed dose to water and the corrected absorbed dose in the sensitive volume of the chamber of up to 1% and 0.6% for the 10 mm and 30 mm applicators, respectively. Calculations using a depth-dependent perturbation factor, including or excluding a shift of the effective point of measurement, resulted in depth-dose differences of about ± 0.5% or less for both applicators. The smallest depth-dose differences were obtained when a shift of the effective point of measurement was implemented, being displaced 0.4 mm towards the center of the sensitive volume of the chamber. The correction factors were obtained with combined uncertainties of 0.4% (k = 2). Uncertainties due to chamber-to-chamber differences are found to be lower than 2%.
The results emphasize the relevance of carrying out detailed Monte Carlo studies for each electronic brachytherapy device and ionization chamber used for its dosimetry.
Collapse
|
60
|
Zaragoza FJ, Eichmann M, Flühs D, Timmermann B, Brualla L. Monte Carlo Computation of Dose-Volume Histograms in Structures at Risk of an Eye Irradiated with Heterogeneous Ruthenium-106 Plaques. Ocul Oncol Pathol 2020; 6:353-359. [PMID: 33123529 DOI: 10.1159/000508113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2020] [Accepted: 04/18/2020] [Indexed: 11/19/2022] Open
Abstract
Background/Aims The aim of this work is to compare Monte Carlo simulated absorbed dose distributions obtained from <sup>106</sup>Ru eye plaques, whose heterogeneous emitter distribution is known, with the common homogeneous approximation. The effect of these heterogeneities on segmented structures at risk is analyzed using an anthropomorphic phantom. Methods The generic CCA and CCB, with a homogeneous emitter map, and the specific CCA1364 and CCB1256 <sup>106</sup>Ru eye plaques are modeled with the Monte Carlo code PENELOPE. To compare the effect of the heterogeneities in the segmented volumes, cumulative dose-volume histograms are calculated for different rotations of the aforementioned plaques. Results For the cornea, the CCA with the equatorial placement yields the lowest absorbed dose rate while for the CCA1364 in the same placement the absorbed dose rate is 33% higher. The CCB1256 with the hot spot oriented towards the cornea yields the maximum dose rate per unit of activity while it is 44% lower for the CCB. Conclusions Dose calculations based on a homogeneous distribution of the emitter substance yield the lowest absorbed dose in the analyzed structures for all plaque placements. Treatment planning based on such calculations may result in an overdose of the structures at risk.
Collapse
Affiliation(s)
| | - Marion Eichmann
- Fakultät Physik, Technische Universität Dortmund, Dortmund, Germany
| | - Dirk Flühs
- NCTeam, Strahlenklinik, Universitätsklinikum Essen, Essen, Germany
| | - Beate Timmermann
- West German Proton Therapy Center Essen (WPE), Essen, Germany.,West German Cancer Center (WTZ), Essen, Germany.,University Hospital Essen, Essen, Germany.,German Cancer Consortium (DKTK), Essen, Germany.,Department of Particle Therapy, University Hospital Essen, Essen, Germany
| | - Lorenzo Brualla
- West German Proton Therapy Center Essen (WPE), Essen, Germany.,West German Cancer Center (WTZ), Essen, Germany.,University Hospital Essen, Essen, Germany
| |
Collapse
|
61
|
Torres Díaz J, Grad GB, Venencia CD, Bonzi EV. A novel and fast methodology to calculate doses in LDR brachytherapy. Appl Radiat Isot 2020; 166:109394. [PMID: 33091859 DOI: 10.1016/j.apradiso.2020.109394] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2020] [Revised: 07/19/2020] [Accepted: 08/18/2020] [Indexed: 10/23/2022]
Abstract
We present the concept of a new methodology for faster simulation of the doses in brachytherapy with permanent implants, based on the knowledge of the seeds arrangement, adding previously simulated doses in an equivalent medium in terms of the atomic composition of the organ in question. To perform the doses calculations we use Monte Carlo simulations. We simulated a cylindrical I-125 seed and compared our results against published data. Our proposal is to have the doses simulated previously in different arrangement of seed-absorbents, and then, considering the spacial positions of the seeds after the implants, these doses can be directly added, obtaining a very fast computation of the total dose. Two phantoms of prostates with permanent implant seeds in 2D and 3D arrangements were simulated. The results of the proposed methodology were compared with two complete Monte Carlo simulations in 2D and 3D designs. Differences in doses were analysed, obtaining statistical discrepancies of less than 1% and reducing the simulation time by more than 4 orders of magnitude. With the proposed methodology, it is possible to perform rapid dose calculations in brachytherapy, using laptop or desktop computers.
Collapse
Affiliation(s)
- Jorge Torres Díaz
- CONICET, Córdoba, Argentina; FaMAF, Universidad Nacional de Córdoba, Córdoba, Argentina
| | | | | | | |
Collapse
|
62
|
Giménez-Alventosa V, Giménez V, Ballester F, Vijande J, Andreo P. Monte Carlo calculation of beam quality correction factors for PTW cylindrical ionization chambers in photon beams. ACTA ACUST UNITED AC 2020; 65:205005. [DOI: 10.1088/1361-6560/ab9501] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
63
|
Roa D, Moyses H, Leon S, Hamrick B, Sarria GR, Li B, Tajima T, Necas A, Guzman C, Paucar O, Gonzales A, Challco R, Montoya M, Arqque Z, Gonzales A, Hernandez J, Drake J, Villane R, Lea J. Dose simulations of an early 20th century kilovoltage pneumonia radiotherapy technique performed with a modern fluoroscope. Med Dosim 2020; 46:74-79. [PMID: 32958360 PMCID: PMC7500403 DOI: 10.1016/j.meddos.2020.08.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Revised: 07/30/2020] [Accepted: 08/20/2020] [Indexed: 12/26/2022]
Abstract
To simulate an early 20th century viral pneumonia radiotherapy treatment using modern fluoroscopy and evaluated it according to current dose guidelines. Monte Carlo was used to assess the dose distribution on an anthropomorphic phantom. Critical organs were: skin, breasts, esophagus, ribs, vertebrae, heart, thymus, and spinal cord. A 100 kVp beam with 3 mm Al HVL, 25 × 25 cm2 posterior-anterior (PA) field and 50 cm source-to-surface distance were simulated. Simulations had a resolution of 0.4 × 0.4 × 0.06 cm3 and a 6% uncertainty. Hundred percent dose was normalized to the skin surface and results were displayed in axial, coronal, and sagittal planes. Dose volume histograms were generated in MATLAB for further analysis. Prescription doses of 0.3, 0.5, and 1.0 Gy were applied to the 15% isodose for organ-dose comparison to current tolerances and potential risk of detriment. Ninety-five and ninety-seven percent of the right and left lung volumes, respectively, were well-covered by the 15% isodose line. For the 0.3, 0.5, and 1.0 Gy prescriptions, the maximum skin doses were 2.9, 4.8, and 9.6 Gy compared to a 2.0 Gy transient erythema dose threshold; left/right lung maximum doses were 1.44/1.46, 2.4/2.4, and 4.8/4.9 Gy compared to a 6.5 Gy pneumonitis and 30 Gy fibrosis thresholds; maximum heart doses were 0.5, 0.9, and 1.8 Gy compared to the 0.5 Gy ICRP-recommendation; maximum spinal cord doses were 1.4, 2.3, and 4.6 Gy compared to 7.0 Gy single fraction dose threshold. Maximum doses to other critical organs were below modern dose thresholds. A 100 kVp PA field could deliver a 0.3 Gy or 0.5 Gy dose without risk of complications. However, a 1.0 Gy dose treatment could be problematic. Critical organ doses could be further reduced if more than one treatment field is used.
Collapse
Affiliation(s)
- Dante Roa
- Department of Radiation Oncology, University of California, Irvine Health, Orange, CA 92868, USA.
| | - Harry Moyses
- Department of Radiation Oncology, University of California, Irvine Health, Orange, CA 92868, USA
| | - Stephanie Leon
- Department of Radiology, University of Florida, Gainesville, FL 32610, USA
| | - Barbara Hamrick
- Environmental Health and Safety, University of California, Irvine Health, Orange, CA 92868, USA
| | - Gustavo R Sarria
- Department of Radiation Oncology, University Hospital Bonn, University of Bonn, Bonn, Germany
| | - Benjamin Li
- Department of Radiation Oncology, University of California, San Francisco, CA 94115, USA
| | - Toshiki Tajima
- Department of Physics and Astronomy, University of California, Irvine, CA 92697, USA
| | - Ales Necas
- TAE Technologies, Foothill Ranch, CA 92610, USA
| | - Carmen Guzman
- Facultad de Ciencias Naturales y Matematica, Universidad Nacional Federico Villarreal, Lima, Peru
| | - Oliver Paucar
- Facultad de Ingenieria Electrica y Electronica, Universidad Nacional de Ingenieria, Lima, Peru
| | - Alberto Gonzales
- Facultad de Ciencias, Universidad Nacional de Ingenieria, Lima, Peru
| | - Roger Challco
- Facultad de Ciencias, Universidad Nacional de Ingenieria, Lima, Peru
| | - Modesto Montoya
- Facultad de Ciencias, Universidad Nacional de Ingenieria, Lima, Peru
| | - Zintia Arqque
- Facultad de Ciencias, Universidad Nacional de Ingenieria, Lima, Peru
| | | | | | | | | | - Jon Lea
- GE Healthcare, Salt Lake Ciry, UT 84116, USA
| |
Collapse
|
64
|
Material characterization and Monte Carlo simulation of lead and non-lead X-Ray shielding materials. Radiat Phys Chem Oxf Engl 1993 2020. [DOI: 10.1016/j.radphyschem.2020.108892] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
65
|
Omar A, Andreo P, Poludniowski G. A model for the energy and angular distribution of x rays emitted from an x-ray tube. Part I. Bremsstrahlung production. Med Phys 2020; 47:4763-4774. [PMID: 32609887 DOI: 10.1002/mp.14359] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2020] [Revised: 05/01/2020] [Accepted: 05/14/2020] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To develop an analytical model for bremsstrahlung production in a thick x-ray target (i.e., the x-ray tube anode) that takes into account the intrinsic bremsstrahlung angular distribution. METHODS X-ray spectrum models developed from theoretical principles have traditionally treated the angular distribution of the bremsstrahlung production as spherically uniform. This assumption stems from the rationale that electrons promptly attain a diffuse directional distribution in an x-ray target due to multiple scattering, thereby effectively masking the intrinsic bremsstrahlung angular distribution. In this work, a model that explicitly accounts for the angular distribution of the bremsstrahlung production is presented. The model combines Monte Carlo-calculated depth, energy, and angular distributions of electrons penetrating the x-ray target, and incorporates theoretical results for the differential bremsstrahlung cross section. The effects of using different simplified model assumptions for the electron penetration and the intrinsic bremsstrahlung angular distribution are analyzed for tungsten and molybdenum targets in the energy range 20-300 keV. RESULTS Typical assumptions of previous models are shown to introduce errors in calculated spectra. Particularly, it is shown that predictions of fluence and air kerma free-in-air can be overestimated by 15-30% (2-3% in aluminum half-value layer thickness) for clinically relevant beam qualities. The present model is able to reproduce comprehensive Monte Carlo calculations of the bremsstrahlung production generally to within 1%. CONCLUSIONS The bremsstrahlung model developed in this work is an improvement over previous models in that the main features of the electron penetration and the resulting bremsstrahlung are considered in detail. The model can be used for more accurate predictions of the energy and angular distribution of x rays emitted from an x-ray tube.
Collapse
Affiliation(s)
- Artur Omar
- Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Stockholm, 17176, Sweden.,Department of Oncology-Pathology, Karolinska Institutet, Stockholm, 17176, Sweden
| | - Pedro Andreo
- Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Stockholm, 17176, Sweden.,Department of Oncology-Pathology, Karolinska Institutet, Stockholm, 17176, Sweden
| | - Gavin Poludniowski
- Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Stockholm, 17176, Sweden.,Department of Oncology-Pathology, Karolinska Institutet, Stockholm, 17176, Sweden
| |
Collapse
|
66
|
Omar A, Andreo P, Poludniowski G. A model for the energy and angular distribution of x rays emitted from an x-ray tube. Part II. Validation of x-ray spectra from 20 to 300 kV. Med Phys 2020; 47:4005-4019. [PMID: 32593216 DOI: 10.1002/mp.14360] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2020] [Revised: 05/22/2020] [Accepted: 06/11/2020] [Indexed: 11/12/2022] Open
Abstract
PURPOSE To present and validate a complete x-ray emission model (bremsstrahlung and characteristic x-ray emission) for the energy range 20-300 kV. METHODS An analytical x-ray spectrum model that combines the bremsstrahlung emission model developed in Part I with a previously developed characteristic x-ray emission model is validated by comparison with Monte Carlo calculations, published measured spectra, and models developed by other authors. Furthermore, the assumptions and limitations of previous spectrum models are summarized, and their predictions are compared with results obtained by Monte Carlo simulations of x rays emitted from tungsten and molybdenum targets. RESULTS The model is able to reproduce narrow-beam Monte Carlo calculations to within 0.5% in terms of the first and second aluminum half-value layer thickness (HVL). Compared with measured spectra, the difference in HVL is < 2% for typical diagnostic and therapeutic beam qualities available at primary standard laboratories. Compared with previous spectrum models, the present model performs especially well for low kilovoltage x-ray beams (below 50 kV), and is reliable for a wider range of take-off angles, that is, the angle between the target surface and the direction of emission. The difference in model and Monte Carlo predictions of the energy-fluence weighted air kerma (i.e., the photon energy absorption in air) is < 0.5% using the present model, while previous spectrum models can differ by more than 10%. CONCLUSIONS The x-ray emission model developed in this work has been validated against Monte Carlo calculations and measured results. The model provides an efficient alternative to comprehensive Monte Carlo simulations and is an improvement over previous models. The model can be used to predict both central- and off-axis spectra, as well as off-axis effects such as the (anode) heel effect.
Collapse
Affiliation(s)
- Artur Omar
- Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Stockholm, 17176, Sweden.,Department of Oncology-Pathology, Karolinska Institutet, Stockholm, 17176, Sweden
| | - Pedro Andreo
- Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Stockholm, 17176, Sweden.,Department of Oncology-Pathology, Karolinska Institutet, Stockholm, 17176, Sweden
| | - Gavin Poludniowski
- Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Stockholm, 17176, Sweden.,Department of Oncology-Pathology, Karolinska Institutet, Stockholm, 17176, Sweden
| |
Collapse
|
67
|
Dosimetric assessment in different tumour phenotypes with auger electron emitting radionuclides: 99mTc, 125I, 161Tb, and 177Lu. Radiat Phys Chem Oxf Engl 1993 2020. [DOI: 10.1016/j.radphyschem.2020.108763] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
68
|
Ghareeb F, Esposito A, Lencart J, Santos JA. Localized extra focal dose collimator angle dependence during VMAT: An out-of-field Monte Carlo study using PRIMO software. Radiat Phys Chem Oxf Engl 1993 2020. [DOI: 10.1016/j.radphyschem.2020.108694] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
69
|
Trevisan Massera R, Tomal A. Estimation of glandular dose in mammography based on artificial neural networks. ACTA ACUST UNITED AC 2020; 65:095009. [DOI: 10.1088/1361-6560/ab7a6d] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
70
|
Andreo P, Burns DT, Kapsch RP, McEwen M, Vatnitsky S, Andersen CE, Ballester F, Borbinha J, Delaunay F, Francescon P, Hanlon MD, Mirzakhanian L, Muir B, Ojala J, Oliver CP, Pimpinella M, Pinto M, de Prez LA, Seuntjens J, Sommier L, Teles P, Tikkanen J, Vijande J, Zink K. Determination of consensus k Q values for megavoltage photon beams for the update of IAEA TRS-398. ACTA ACUST UNITED AC 2020; 65:095011. [DOI: 10.1088/1361-6560/ab807b] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
71
|
Sarin B, Bindhu B, Saju B, Nair RK. Validation of PRIMO Monte Carlo Model of Clinac ®iX 6MV Photon Beam. J Med Phys 2020; 45:24-35. [PMID: 32355432 PMCID: PMC7185709 DOI: 10.4103/jmp.jmp_75_19] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2019] [Revised: 02/20/2020] [Accepted: 02/21/2020] [Indexed: 11/04/2022] Open
Abstract
Purpose This study aims to model 6MV photon of Clinac®iX linear accelerator using PRIMO Monte Carlo (MC) code and to assess PRIMO as an independent MC-based dose verification and quality assurance tool. Materials and Methods The modeling of Clinac®iX linear accelerator has been carried out by using PRIMO simulation software (Version 0.3.1.1681). The simulated beam parameters were compared against the measured beam data of the Clinac®iX machine. The PRIMO simulation model of Clinac®iX was also validated against Eclipse® Acuros XB dose calculations in the case of both homogenous and inhomogeneous mediums. The gamma analysis method with the acceptance criteria of 2%, 2 mm was used for the comparison of dose distributions. Results Gamma analysis shows a minimum pass percentage of 99% for depth dose curves and 95.4% for beam profiles. The beam quality index and output factors and absolute point dose show good agreement with measurements. The validation of PRIMO dose calculations, in both homogeneous and inhomogeneous medium, against Acuros® XB shows a minimum gamma analysis pass rate of 99%. Conclusions This study shows that the research software PRIMO can be used as a treatment planning system-independent quality assurance and dose verification tool in daily clinical practice. Further validation will be performed with different energies, complex multileaf collimators fields, and with dynamic treatment fields.
Collapse
Affiliation(s)
- B Sarin
- Department of Physics, Noorul Islam Centre For Higher Education, Kumaracoil, Kanyakumari, Tamil Nadu, India.,Division of Radiation Physics, Regional Cancer Centre, Thiruvananthapuram, Kerala, India
| | - B Bindhu
- Department of Physics, Noorul Islam Centre For Higher Education, Kumaracoil, Kanyakumari, Tamil Nadu, India
| | - B Saju
- Division of Radiation Physics, Regional Cancer Centre, Thiruvananthapuram, Kerala, India
| | - Raguram K Nair
- Division of Radiation Physics, Regional Cancer Centre, Thiruvananthapuram, Kerala, India
| |
Collapse
|
72
|
Santoro-Fernandes V, Santos JC, Mariano L, Vanin VR, Costa PR. Uncertainty estimation and statistical comparative methodology for mammography x-ray energy spectra. Biomed Phys Eng Express 2020; 6:035018. [PMID: 33438663 DOI: 10.1088/2057-1976/ab817d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Numerical models are an alternative to measurements of x-ray energy spectra when validated by comparative methods that assess the similarity of experimental and calculated spectra. In this work, we compared x-ray energy spectra using several methodologies and determined the methodology with highest statistical power among them. Experiments and Monte Carlo (MC) simulations were used to generate a set of 65 experimental and simulated x-ray mammography spectra pairs typically used in mammography applications. They were generated using Tungsten and Molybdenum targets and Molybdenum and Rhodium filters. The x-ray beams were transmitted through breast tissue equivalent material (bTEM) plates with different glandularities and thicknesses, and the transmitted beam was detected using solid-state x-ray spectrometry with a Cadmium Telluride (CdTe) diode. The MC simulations used the PENELOPE code. Additional uncertainties, beyond that from counting, were propagated using the MC method. Quantitative comparative methods based on the [Formula: see text] statistics, the first and second half-value layers, the mean energy, the effective energy, and the non-parametric u-test were applied and their specificity (true negative rate) was assessed. The polyenergetic normalized glandular dose (DgNp) to a 6 cm breast of 50/50 glandularity was derived from the spectra. In this work, the [Formula: see text] statistics attained the highest score; therefore, it is the most indicated metric for the x-ray energy spectra comparative evaluations. The contribution of the additional uncertainties was important, being responsible for up to 98% of the spectra total uncertainty and shifting the mean of the evaluated [Formula: see text] to 1.2(1), compatible with its expected value. The use of non-parametric test is discouraged by our results, since it failed to distinguish spectra pairs that resulted in up to 72% discrepant DgNp.
Collapse
|
73
|
Tikkanen J, Zink K, Pimpinella M, Teles P, Borbinha J, Ojala J, Siiskonen T, Gomà C, Pinto M. Calculated beam quality correction factors for ionization chambers in MV photon beams. Phys Med Biol 2020; 65:075003. [PMID: 31995531 DOI: 10.1088/1361-6560/ab7107] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The beam quality correction factor, [Formula: see text], which corrects for the difference in the ionization chamber response between the reference and clinical beam quality, is an integral part of radiation therapy dosimetry. The uncertainty of [Formula: see text] is one of the most significant sources of uncertainty in the dose determination. To improve the accuracy of available [Formula: see text] data, four partners calculated [Formula: see text] factors for 10 ionization chamber models in linear accelerator beams with accelerator voltages ranging from 6 MV to 25 MV, including flattening-filter-free (FFF) beams. The software used in the calculations were EGSnrc and PENELOPE, and the ICRU report 90 cross section data for water and graphite were included in the simulations. Volume averaging correction factors were calculated to correct for the dose averaging in the chamber cavities. A comparison calculation between partners showed a good agreement, as did comparison with literature. The [Formula: see text] values from TRS-398 were higher than our values for each chamber where data was available. The [Formula: see text] values for the FFF beams did not follow the same [Formula: see text], [Formula: see text] relation as beams with flattening filter (values for 10 MV FFF beams were below fits made to other data on average by 0.3%), although our FFF sources were only for Varian linacs.
Collapse
Affiliation(s)
- J Tikkanen
- Radiation and Nuclear Safety Authority (STUK), Helsinki, Finland. Helsinki Institute of Physics, University of Helsinki, Helsinki, Finland
| | | | | | | | | | | | | | | | | |
Collapse
|
74
|
Adam DP, Liu T, Caracappa PF, Bednarz BP, Xu XG. New capabilities of the Monte Carlo dose engine ARCHER-RT: Clinical validation of the Varian TrueBeam machine for VMAT external beam radiotherapy. Med Phys 2020; 47:2537-2549. [PMID: 32175615 DOI: 10.1002/mp.14143] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2019] [Revised: 02/03/2020] [Accepted: 02/10/2020] [Indexed: 11/08/2022] Open
Abstract
PURPOSE The Monte Carlo radiation transport method is considered the most accurate approach for absorbed dose calculations in external beam radiation therapy. In this study, an efficient and accurate source model of the Varian TrueBeam 6X STx Linac is developed and integrated with a fast Monte Carlo photon-electron transport absorbed dose engine, ARCHER-RT, which is capable of being executed on CPUs, NVIDIA GPUs, and AMD GPUs. This capability of fast yet accurate radiation dose calculation is essential for clinical utility of this new technology. This paper describes the software and algorithmic developments made to the ARCHER-RT absorbed dose engine. METHODS AMD's Heterogeneous-Compute Interface for Portability (HIP) was implemented in ARCHER-RT to allow for device independent execution on NVIDIA and AMD GPUs. Architecture-specific atomic-add algorithms have been identified and both more accurate single-precision and double-precision computational absorbed dose calculation methods have been added to ARCHER-RT and validated through a test case to evaluate the accuracy and performance of the algorithms. The validity of the source model and the radiation transport physics were benchmarked against Monte Carlo simulations performed with EGSnrc. Secondary dose-check physics plans, and a clinical prostate treatment plan were calculated to demonstrate the applicability of the platform for clinical use. Absorbed dose difference maps and gamma analyses were conducted to establish the accuracy and consistency between the two Monte Carlo models. Timing studies were conducted on a CPU, an NVIDIA GPU, and an AMD GPU to evaluate the computational speed of ARCHER-RT. RESULTS Percent depth doses were computed for different field sizes ranging from 1.5 cm2 × 1.5 cm2 to 22 cm2 × 40cm2 and the two codes agreed for all points outside high gradient regions within 3%. Axial profiles computed for a 10 cm2 × 10 cm2 field for multiple depths agreed for all points outside high gradient regions within 2%. The test case investigating the impact of native single-precision compared to double-precision showed differences in voxels as large as 71.47% and the implementation of KAS single-precision reduced the difference to less than 0.01%. The 3%/3mm gamma pass rates for an MPPG5a multileaf collimator (MLC) test case and a clinical VMAT prostate plan were 94.2% and 98.4% respectively. Timing studies demonstrated the calculation of a VMAT plan was completed in 50.3, 187.9, and 216.8 s on an NVIDIA GPU, AMD GPU, and Intel CPU, respectively. CONCLUSION ARCHER-RT is capable of patient-specific VMAT external beam photon absorbed dose calculations and its potential has been demonstrated by benchmarking against a well validated EGSnrc model of a Varian TrueBeam. Additionally, the implementation of AMD's HIP has shown the flexibility of the ARCHER-RT platform for device independent calculations. This work demonstrates the significant addition of functionality added to ARCHER-RT framework which has marked utility for both research and clinical applications and demonstrates further that Monte Carlo-based absorbed dose engines like ARCHER-RT have the potential for widespread clinical implementation.
Collapse
Affiliation(s)
- David P Adam
- Medical Physics, University of Wisconsin Madison, 1111 Highland Avenue, Madison, WI, 53705, USA
| | - Tianyu Liu
- Nuclear Engineering, Rensselaer Polytechnic Institute, 110 8th Street, Troy, NY, 12180, USA
| | | | - Bryan P Bednarz
- Medical Physics, University of Wisconsin Madison, 1111 Highland Avenue, Madison, WI, 53705, USA
| | - Xie George Xu
- Nuclear Engineering, Rensselaer Polytechnic Institute, 110 8th Street, Troy, NY, 12180, USA
| |
Collapse
|
75
|
|
76
|
Kaveckyte V, Persson L, Malusek A, Benmakhlouf H, Alm Carlsson G, Carlsson Tedgren Å. Investigation of a synthetic diamond detector response in kilovoltage photon beams. Med Phys 2019; 47:1268-1279. [PMID: 31880809 DOI: 10.1002/mp.13988] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2019] [Revised: 09/04/2019] [Accepted: 12/01/2019] [Indexed: 12/28/2022] Open
Abstract
PURPOSE An important characteristic of radiation dosimetry detectors is their energy response which consists of absorbed-dose and intrinsic energy responses. The former can be characterized using Monte Carlo (MC) simulations, whereas the latter (i.e., detector signal per absorbed dose to detector) is extracted from experimental data. Such a characterization is especially relevant when detectors are used in nonrelative measurements at a beam quality that differs from the calibration beam quality. Having in mind the possible application of synthetic diamond detectors (microDiamond PTW 60019, Freiburg, Germany) for nonrelative dosimetry of low-energy brachytherapy (BT) beams, we determined their intrinsic and absorbed-dose energy responses in 25-250 kV beams relative to a 60 Co beam, which is usually the reference beam quality for detector calibration in radiotherapy. MATERIAL AND METHODS Three microDiamond detectors and, for comparison, two silicon diodes (PTW 60017) were calibrated in terms of air-kerma free in air in six x-ray beam qualities (from 25 to 250 kV) and in terms of absorbed dose to water in a 60 Co beam at the national metrology laboratory in Sweden. The PENELOPE/penEasy MC radiation transport code was used to calculate the absorbed-dose energy response of the detectors (modeled based on blueprints) relative to air and water depending on calibration conditions. The MC results were used to extract the relative intrinsic energy response of the detectors from the overall energy response. Measurements using an independent setup with a single ophthalmic BEBIG I25.S16 125 I BT seed (effective photon energy of 28 keV) were used as a qualitative check of the extracted intrinsic energy response correction factors. Additionally, the impact of the thickness of the active volume as well as the presence of extra-cameral components on the absorbed-dose energy response of a microDiamond detector was studied using MC simulations. RESULTS The relative intrinsic energy response of the microDiamond detectors was higher by a factor of 2 in 25 and 50 kV beams compared to the 60 Co beam. The variation in the relative intrinsic energy response of silicon diodes was within 10% over the investigated photon energy range. The use of relative intrinsic energy response correction factors improved the agreement among the absorbed dose to water values determined using microDiamond detectors and silicon diodes, as well as with the TG-43 formalism-based calculations for the 125 I seed. MC study of microDiamond detector design features provided a possible explanation for inter-detector response variation at low-energy photon beams by differences in the effective thickness of the active volume. CONCLUSIONS MicroDiamond detectors had a non-negligible variation in the relative intrinsic energy response (factor of 2) which was comparable to that in the absorbed-dose energy response relative to water at low-energy photon beams. Silicon diodes, in contrast, had an absorbed-dose energy dependence on photon energy that varied by a factor of 6, whereas the intrinsic energy dependence on beam quality was within 10%. It is important to decouple these two responses for a full characterization of detector energy response especially when the user and reference beam qualities differ significantly, and MC alone is not enough.
Collapse
Affiliation(s)
- Vaiva Kaveckyte
- Radiation Physics, Department of Medical and Health Sciences, Linköping University, SE-581 85, Linköping, Sweden.,Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, SE-171 76, Stockholm, Sweden
| | - Linda Persson
- Swedish Radiation Safety Authority, SE-171 16, Stockholm, Sweden
| | - Alexandr Malusek
- Radiation Physics, Department of Medical and Health Sciences, Linköping University, SE-581 85, Linköping, Sweden
| | - Hamza Benmakhlouf
- Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, SE-171 76, Stockholm, Sweden
| | - Gudrun Alm Carlsson
- Radiation Physics, Department of Medical and Health Sciences, Linköping University, SE-581 85, Linköping, Sweden
| | - Åsa Carlsson Tedgren
- Radiation Physics, Department of Medical and Health Sciences, Linköping University, SE-581 85, Linköping, Sweden.,Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, SE-171 76, Stockholm, Sweden
| |
Collapse
|
77
|
Valdes-Cortez C, Niatsetski Y, Ballester F, Vijande J, Candela-Juan C, Perez-Calatayud J. On the use of the absorbed depth-dose measurements in the beam calibration of a surface electronic high-dose-rate brachytherapy unit, a Monte Carlo-based study. Med Phys 2019; 47:693-702. [PMID: 31722113 DOI: 10.1002/mp.13920] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2019] [Revised: 11/06/2019] [Accepted: 11/06/2019] [Indexed: 01/25/2023] Open
Abstract
PURPOSE To evaluate the use of the absorbed depth-dose as a surrogate of the half-value layer in the calibration of a high-dose-rate electronic brachytherapy (eBT) equipment. The effect of the manufacturing tolerances and the absorbed depth-dose measurement uncertainties in the calibration process are also addressed. METHODS The eBT system Esteya® (Elekta Brachytherapy, Veenendaal, The Netherlands) has been chosen as a proof-of-concept to illustrate the feasibility of the proposed method, using its 10 mm diameter applicator. Two calibration protocols recommended by the AAPM (TG-61) and the IAEA (TRS-398) for low-energy photon beams were evaluated. The required Monte Carlo (MC) simulations were carried out using PENELOPE2014. Several MC simulations were performed modifying the flattening filter thickness and the x-ray tube potential, generating one absorbed depth-dose curve and a complete set of parameters required in the beam calibration (i.e., HVL, backscatter factor (Bw ), and mass energy-absorption coefficient ratios (µen /ρ)water,air ), for each configuration. Fits between each parameter and some absorbed dose-ratios calculated from the absorbed depth-dose curves were established. The effect of the manufacturing tolerances and the absorbed dose-ratio uncertainties over the calibration process were evaluated by propagating their values over the fitting function, comparing the overall calibration uncertainties against reference values. We proposed four scenarios of uncertainty (from 0% to 10%) in the dose-ratio determination to evaluate its effect in the calibration process. RESULTS The manufacturing tolerance of the flattening filter (±0.035 mm) produces a change of 1.4% in the calculated HVL and a negligible effect over the Bw , (µen /ρ)water,air , and the overall calibration uncertainty. A potential variation of 14% of the electron energies due to manufacturing tolerances in the x-ray tube (69.5 ± ~10 keV) generates a variation of 10% in the HVL. However, this change has a negligible effect over the Bw and (µen /ρ)water,air , adding 0.1% to the overall calibration uncertainty. The fitting functions reproduce the data with an uncertainty (k = 2) below 1%, 0.5%, and 0.4% for the HVL, Bw , and (µen /ρ)water,air , respectively. The four studied absorbed dose-ratio uncertainty scenarios add, in the worst-case scenario, 0.2% to the overall uncertainty of the calibration process. CONCLUSIONS This work shows the feasibility of using the absorbed depth-dose curve in the calibration of an eBT system with minimal loss of precision.
Collapse
Affiliation(s)
- Christian Valdes-Cortez
- Departamento de Física Atómica, Molecular y Nuclear, Universidad de Valencia (UV), Valencia, 46100, Spain.,Radiotherapy Department, Centro Oncológico del Norte, Antofagasta, 1240000, Chile
| | - Yury Niatsetski
- R&D Elekta Brachytherapy, Waardgelder 1, 3905 TH, Veenendaal, The Netherlands
| | - Facundo Ballester
- Departamento de Física Atómica, Molecular y Nuclear, Universidad de Valencia (UV), Valencia, 46100, Spain.,IRIMED Joint Research Unit (IIS La Fe - UV), Valencia, Spain
| | - Javier Vijande
- Departamento de Física Atómica, Molecular y Nuclear, Universidad de Valencia (UV), Valencia, 46100, Spain.,IRIMED Joint Research Unit (IIS La Fe - UV), Valencia, Spain
| | - Cristian Candela-Juan
- Centro Nacional de Dosimetría (CND), Instituto Nacional de Gestión Sanitaria, Valencia, 46009, Spain
| | - Jose Perez-Calatayud
- IRIMED Joint Research Unit (IIS La Fe - UV), Valencia, Spain.,Radiotherapy Department, La Fe Hospital, Valencia, 46026, Spain
| |
Collapse
|
78
|
|
79
|
Baumann K, Horst F, Zink K, Gomà C. Comparison of penh, fluka, and Geant4/topas for absorbed dose calculations in air cavities representing ionization chambers in high-energy photon and proton beams. Med Phys 2019; 46:4639-4653. [PMID: 31350915 PMCID: PMC6851981 DOI: 10.1002/mp.13737] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2018] [Revised: 07/01/2019] [Accepted: 07/16/2019] [Indexed: 12/16/2022] Open
Abstract
PURPOSE The purpose of this work is to analyze whether the Monte Carlo codes penh, fluka, and geant4/topas are suitable to calculate absorbed doses andf Q / f Q 0 ratios in therapeutic high-energy photon and proton beams. METHODS We used penh, fluka, geant4/topas, and egsnrc to calculate the absorbed dose to water in a reference water cavity and the absorbed dose to air in two air cavities representative of a plane-parallel and a cylindrical ionization chamber in a 1.25 MeV photon beam and a 150 MeV proton beam - egsnrc was only used for the photon beam calculations. The physics and transport settings in each code were adjusted to simulate the particle transport as detailed as reasonably possible. From these absorbed doses, f Q 0 factors, f Q factors, andf Q / f Q 0 ratios (which are the basis of Monte Carlo calculated beam quality correction factors k Q , Q 0 ) were calculated and compared between the codes. Additionally, we calculated the spectra of primary particles and secondary electrons in the reference water cavity, as well as the integrated depth-dose curve of 150 MeV protons in water. RESULTS The absorbed doses agreed within 1.4% or better between the individual codes for both the photon and proton simulations. The f Q 0 and f Q factors agreed within 0.5% or better for the individual codes for both beam qualities. The resultingf Q / f Q 0 ratios for 150 MeV protons agreed within 0.7% or better. For the 1.25 MeV photon beam, the spectra of photons and secondary electrons agreed almost perfectly. For the 150 MeV proton simulation, we observed differences in the spectra of secondary protons whereas the spectra of primary protons and low-energy delta electrons also agreed almost perfectly. The first 2 mm of the entrance channel of the 150 MeV proton Bragg curve agreed almost perfectly while for greater depths, the differences in the integrated dose were up to 1.5%. CONCLUSION penh, fluka, and geant4/topas are capable of calculating beam quality correction factors in proton beams. The differences in the f Q 0 and f Q factors between the codes are 0.5% at maximum. The differences in thef Q / f Q 0 ratios are 0.7% at maximum.
Collapse
Affiliation(s)
- Kilian‐Simon Baumann
- Department of Radiotherapy and RadiooncologyUniversity Medical Center Giessen‐MarburgMarburgGermany
- Institute of Medical Physics and Radiation ProtectionUniversity of Applied SciencesGiessenGermany
| | - Felix Horst
- Institute of Medical Physics and Radiation ProtectionUniversity of Applied SciencesGiessenGermany
- GSI Helmholtzzentrum für SchwerionenforschungDarmstadtGermany
| | - Klemens Zink
- Department of Radiotherapy and RadiooncologyUniversity Medical Center Giessen‐MarburgMarburgGermany
- Institute of Medical Physics and Radiation ProtectionUniversity of Applied SciencesGiessenGermany
- Frankfurt Institute for Advanced Studies (FIAS)FrankfurtGermany
| | - Carles Gomà
- Department of Oncology, Laboratory of Experimental RadiotherapyKU LeuvenLeuvenBelgium
| |
Collapse
|
80
|
Lee C, Badal A, Yeom YS, Griffin K, McMillan D. Dosimetric impact of voxel resolutions of computational human phantoms for external photon exposure. Biomed Phys Eng Express 2019; 5:065002. [PMID: 38500848 PMCID: PMC10948017 DOI: 10.1088/2057-1976/ab2850] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Several research teams have developed computational phantoms in polygonal-mesh (PM) and/or Non-Uniform Rational B-Spline format, but it has not been systematically evaluated if the existing voxel phantoms are still dosimetrically valid. We created three voxel phantoms with the resolutions of 1,000, 125, and 1 mm3 and simulated the irradiation in antero-posterior geometry with photons of 0.1, 1, and 10 MeV using voxel Monte Carlo codes, and compared the energy deposition to their organs/tissues with the values from the original PM phantom using mesh Monte Carlo codes. The coefficient of variation in energy deposition overall showed about five-fold decrease as the voxel resolution increased but differences were mostly less than 5% for any voxel resolution. We conclude that PM phantoms and mesh Monte Carlo techniques may not be necessary for external photon exposure (0.1 - 10 MeV) and the existing voxel phantoms can provide enough dosimetric accuracy in those exposure conditions.
Collapse
Affiliation(s)
- Choonsik Lee
- Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Rockville, MD
| | - Andreu Badal
- Division of Imaging, Diagnostics and Software Reliability, OSEL, CDRH, Food and Drug Administration, Silver Spring, MD
| | - Yeon Soo Yeom
- Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Rockville, MD
| | - Keith Griffin
- Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Rockville, MD
| | - Dayton McMillan
- Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Rockville, MD
| |
Collapse
|
81
|
Gomà C, Sterpin E. Monte Carlo calculation of beam quality correction factors in proton beams using PENH. ACTA ACUST UNITED AC 2019; 64:185009. [DOI: 10.1088/1361-6560/ab3b94] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
82
|
Vargas A, Arnold D, Duch MA, Evangeliou N, Sievers K, Maurer C. Dose calculations in aircrafts after Fukushima nuclear power plant accident - Preliminary study for aviation operations. JOURNAL OF ENVIRONMENTAL RADIOACTIVITY 2019; 205-206:24-33. [PMID: 31096105 DOI: 10.1016/j.jenvrad.2019.04.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2018] [Revised: 04/23/2019] [Accepted: 04/26/2019] [Indexed: 06/09/2023]
Abstract
There is little information to decision support in air traffic management in case of nuclear releases into the atmosphere. In this paper, the dose estimation due to both, external exposure (i.e. cloud immersion, deposition inside and outside the aircraft), and due to internal exposure (i.e, inhalation of radionuclides inside the aircraft) to passengers and crew is calculated for a worst-case emergency scenario. The doses are calculated for different radionuclides and activities. Calculations are mainly considered according to International Commission on Radiological Protection (ICRP) recommendations and Monte Carlo simulations. In addition, a discussion on potential detectors installed inside the aircraft for monitoring the aerosol concentration and the ambient dose equivalent rate, H*(10), for during-flight monitoring and early warning is provided together with the evaluation of a response of a generic detector. The results show that the probability that a catastrophic nuclear accident would produce significant radiological doses to the passengers and crew of an aircraft is very low. In the worst-case scenarios studied, the maximum estimated effective dose was about 1 mSv during take-off or landing operations, which is the recommended yearly threshold for the public. However, in order to follow the ALARA (As Low As Reasonably Achievable) criteria and to avoid aircraft contamination, the installation of radiological detectors is considered. This would, on one hand help the pilot or corresponding decision maker to decide about the potential change of the route and, on the other, allow for gathering of 4D data for future studies.
Collapse
Affiliation(s)
- A Vargas
- Institute of Energy Technologies, Technical University of Catalonia, Barcelona, Spain.
| | - D Arnold
- ZAMG-Zentralanstalt für Meteorologie und Geodynamik, Vienna, Austria; Arnold Scientific Consulting, ASC, Manresa, Spain
| | - M-A Duch
- Institute of Energy Technologies, Technical University of Catalonia, Barcelona, Spain
| | - N Evangeliou
- NILU-Norwegian Institute for Air Research, Kjeller, Norway
| | - K Sievers
- Klaus Sievers Aviation Weather, Lenggries, Germany
| | - C Maurer
- ZAMG-Zentralanstalt für Meteorologie und Geodynamik, Vienna, Austria
| |
Collapse
|
83
|
Hartmann GH, Andreo P. Fluence calculation methods in Monte Carlo dosimetry simulations. Z Med Phys 2019; 29:239-248. [DOI: 10.1016/j.zemedi.2018.08.003] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2018] [Revised: 07/04/2018] [Accepted: 08/26/2018] [Indexed: 11/25/2022]
|
84
|
Shine NS, Paramu R, Gopinath M, Jaon Bos RC, Jayadevan PM. Out-of-Field Dose Calculation by a Commercial Treatment Planning System and Comparison by Monte Carlo Simulation for Varian TrueBeam ®. J Med Phys 2019; 44:156-175. [PMID: 31576064 PMCID: PMC6764172 DOI: 10.4103/jmp.jmp_82_18] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2018] [Revised: 05/20/2019] [Accepted: 05/20/2019] [Indexed: 02/04/2023] Open
Abstract
PURPOSE The calculation accuracy of treatment planning systems (TPSs) drops drastically when the points outside the field edges are considered. The real accuracy of a TPS and linear accelerator (linac) combination for regions outside the field edge is a subject which demands more study. In this study, the accuracy of out-of-field dose calculated by a TPS, used with a TrueBeam® (TB) linac, is quantified. MATERIALS AND METHODS For dose calculation, Eclipse™ version 13.7 commissioned for TB machine was used. For comparison, Monte Carlo (MC) methods, as well as the measurements, were used. The VirtuaLinac, a Geant 4-based MC program which is offered as a cloud solution, is used for the generation of input phase-space (PS) files. This PS file was imported into PRIMO (PENELOPE based MC program) for the simulation of out-of-field dose. RESULTS In this study, the accuracy of the out-of-field dose calculated by a TPS for a TB linac was estimated. As per the results in comparison with MC simulations, the TPS underestimated the dose by around 45% on an average for the off-axis-distance range considered in this study. As the off-axis distance increased, the underestimation of the dose also increased. CONCLUSION In this work, it was observed that the TPS underestimates doses beyond the edges of treatment fields for a clinical treatment executed on a TB machine. This indicates that the out-of-field dose from TPSs should only be used with a clear understanding of the inaccuracy of dose calculations beyond the edge of the field.
Collapse
Affiliation(s)
- N. S. Shine
- Department of Physics, Banasthali University, Jaipur, Rajasthan, India
| | - Raghukumar Paramu
- Division of Radiation Physics, Regional Cancer Center, Thiruvananthapuram, Kerala, India
| | - M. Gopinath
- Department of Radiation Oncology, Aster Medcity, Kochi, Kerala, India
| | - R. C. Jaon Bos
- Department of Radiation Oncology, Aster Medcity, Kochi, Kerala, India
| | - P. M. Jayadevan
- Department of Radiation Oncology, Aster Medcity, Kochi, Kerala, India
| |
Collapse
|
85
|
Zeghari A, Saaidi R, Cherkaoui El Moursli R. Investigation of variance reduction techniques parameters to enhance the efficiency for a 12 MV photon beam. JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES 2019. [DOI: 10.1080/16878507.2019.1623573] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Affiliation(s)
- A. Zeghari
- Faculty of Sciences, Mohammed 5 University, Rabat, Morocco
| | - R. Saaidi
- Faculty of Sciences, Mohammed 5 University, Rabat, Morocco
| | | |
Collapse
|
86
|
Increasing organ dose accuracy through voxel phantom organ matching with individual patient anatomy. Radiat Phys Chem Oxf Engl 1993 2019. [DOI: 10.1016/j.radphyschem.2019.02.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
87
|
Vidal M, Ibáñez P, Guerra P, Valdivieso-Casique MF, Rodríguez R, Illana C, Udías JM. Fast optimized Monte Carlo phase-space generation and dose prediction for low energy x-ray intra-operative radiation therapy. ACTA ACUST UNITED AC 2019; 64:075002. [DOI: 10.1088/1361-6560/ab03e7] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
88
|
Tse J, Geoghegan S. Calculations of dose point kernels of 64 Cu in different media with PENELOPE Monte Carlo code. Med Phys 2019; 46:2422-2429. [PMID: 30822361 DOI: 10.1002/mp.13465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2018] [Revised: 02/22/2019] [Accepted: 02/22/2019] [Indexed: 11/06/2022] Open
Abstract
PURPOSE The unique decay properties of copper-64 (64 Cu) has made it a radionuclide of interest in theragnostic applications of nuclear medicine. This study aims to calculate the dose point kernels (DPKs) of 64 Cu in various media with PENELOPE Monte Carlo code. METHODS Monte Carlo simulations were performed using PENELOPE code (version 2014). To calculate DPKs, the simulation comprised an isotropic point radiation source positioned at the origin of a spherical object of radius 50 cm. The absorbed dose along the radial direction outwards from the point source were scored with a resolution of 20 μm. Validations were firstly performed by calculating the DPKs of monoenergetic electrons and photons in water and the results were compared against the literature values. The continuous energy spectra of the beta minus and positron emissions from 64 Cu were numerically modeled and used as inputs to the simulation. DPKs of 64 Cu were calculated in water, soft tissue, lung tissue, and cortical bone, including all emissions types. RESULTS The simulations have been successfully validated against literature values. The largest deviations have been observed with 10 keV monoenergetic electrons with the average and maximum dose difference of -1.01% and -10.56%. The modeled energy spectra closely compared with the average energies from Brookhaven Laboratory National Nuclear Data Centre and the combined spectral shapes from the RAdiation Dose Assessment Resource (RADAR). The DPKs of 64 Cu demonstrated different radial dose deposition in different media owing to the different physical density and effective atomic number. CONCLUSIONS The DPKs of 64 Cu have been calculated with Monte Carlo simulations in four different media. They will be useful to study the dosimetric properties of 64 Cu-labeled radiopharmaceuticals and perform therapeutic dose planning.
Collapse
Affiliation(s)
- Jason Tse
- Medical Physics Department, Austin Hospital, Melbourne, VIC, Australia.,Faculty of Health Sciences, University of Sydney, Sydney, NSW, Australia
| | - Sean Geoghegan
- Department of Medical Physics, Royal Adelaide Hospital, Adelaide, SA, Australia
| |
Collapse
|
89
|
Ginjaume M, Carinou E, Brodecki M, Clairand I, Domienik-Andrzejewska J, Exner L, Ferrari P, Jovanović Z, Krstic D, Principi S, Van Hoey O, Vanhavere F. Effect of the radiation protective apron on the response of active and passive personal dosemeters used in interventional radiology and cardiology. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2019; 39:97-112. [PMID: 30523896 DOI: 10.1088/1361-6498/aaf2c0] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
In fluoroscopy guided interventional procedures, workers use protective garments and often two personal dosemeters, the readings of which are used for the estimation of the effective dose; whereas the dosemeter above the protection can be used for the estimation of the equivalent dose of the lens of the eye. When a protective apron is worn the scattered field that reaches the dosemeter is different from the case where no protection is used; this study analyses the changes in the response of seven passive and eight active personal dosemeters (APDs) when they are placed above a lead or lead equivalent garment for S-Cs and x-ray diagnostic qualities. Monte Carlo simulations are used to support the experimental results. It is found that for passive dosemeters, the influence on the dosemeter's response to the lead or lead equivalent was within the range 15%-38% for the x-ray qualities. This effect is smaller, of the order of 10%, when lead-free garments are used, and much smaller, within 1%-10%, for most of the APDs used in the study. From these results it is concluded that when comparing passive and active dosemeter measurements worn above the protection, a difference of 20%-40% is expected. The effect is small when deriving the effective dose from double dosimetry algorithms, but it can be of major importance when eye lens monitoring is based on the use of the dosemeter worn above the protection.
Collapse
Affiliation(s)
- Mercè Ginjaume
- Institut de Tècniques Energètiques, Universitat Politècnica de Catalunya (UPC), Diagonal 647, Barcelona 08028, Spain
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
90
|
Brualla L, Rodriguez M, Sempau J, Andreo P. PENELOPE/PRIMO-calculated photon and electron spectra from clinical accelerators. Radiat Oncol 2019; 14:6. [PMID: 30634994 PMCID: PMC6330451 DOI: 10.1186/s13014-018-1186-8] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2018] [Accepted: 11/19/2018] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The availability of photon and electron spectra in digital form from current accelerators and Monte Carlo (MC) systems is scarce, and one of the packages widely used refers to linacs with a reduced clinical use nowadays. Such spectra are mainly intended for the MC calculation of detector-related quantities in conventional broad beams, where the use of detailed phase-space files (PSFs) is less critical than for MC-based treatment planning applications, but unlike PSFs, spectra can easily be transferred to other computer systems and users. METHODS A set of spectra for a range of Varian linacs has been calculated using the PENELOPE/PRIMO MC system. They have been extracted from PSFs tallied for field sizes of 10 cm × 10 cm and 15 cm × 15 cm for photon and electron beams, respectively. The influence of the spectral bin width and of the beam central axis region used to extract the spectra have been analyzed. RESULTS Spectra have been compared to those by other authors showing good agreement with those obtained using the, now superseded, EGS4/BEAM MC code, but significant differences with the most widely used photon data set. Other spectra, particularly for electron beams, have not been published previously for the machines simulated in this work. The influence of the bin width on the spectrum mean energy for 6 and 10 MV beams has been found to be negligible. The size of the region used to extract the spectra yields differences of up to 40% for the mean energies in 10 MV beams, but the maximum difference for TPR 20,10 values derived from depth-dose distributions does not exceed 2% relative to those obtained using the PSFs. This corresponds to kQ differences below 0.2% for a typical Farmer-type chamber, considered to be negligible for reference dosimetry. Different configurations for using electron spectra have been compared for 6 MeV beams, concluding that the geometry used for tallying the PSFs used to extract the spectra must be accounted for in subsequent calculations using the spectra as a source. CONCLUSIONS An up-to-date set of consistent spectra for Varian accelerators suitable for the calculation of detector-related quantities in conventional broad beams has been developed and made available in digital form.
Collapse
Affiliation(s)
- Lorenzo Brualla
- West German Proton Therapy Centre Essen (WPE), Essen, D-45147, Germany. .,West German Cancer Center (WTZ), Essen, D-45147, Germany. .,University Hospital Essen, Essen, D-45147, Germany. .,Universität Duisburg-Essen, Medizinische Fakultät, Essen, D-45147, Germany.
| | - Miguel Rodriguez
- Centro Médico Paitilla, Panama City, 0816-03075, Panama.,Instituto de Investigaciones Científicas y de Alta Tecnología, INDICASAT-AIP, City of Knowledge, Building 219, Panama City, Panama
| | - Josep Sempau
- Department of Physics and Institute of Energy Technologies, Universitat Politècnica de Catalunya, Barcelona, E-08028, Spain
| | - Pedro Andreo
- Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, and Department of Oncology-Pathology, Karolinska Institutet, Stockholm, SE-171 76, Sweden
| |
Collapse
|
91
|
Rodriguez M, Sempau J, Bäumer C, Timmermann B, Brualla L. DPM as a radiation transport engine for PRIMO. Radiat Oncol 2018; 13:256. [PMID: 30591056 PMCID: PMC6307123 DOI: 10.1186/s13014-018-1188-6] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2018] [Accepted: 11/19/2018] [Indexed: 11/10/2022] Open
Abstract
Background PRIMO is a dose verification system based on the general-purpose Monte Carlo radiation transport code penelope, which implements an accurate physics model of the interaction cross sections and the radiation transport process but with low computational efficiency as compared with fast Monte Carlo codes. One of these fast Monte Carlo codes is the Dose Planning Method (DPM). The purpose of this work is to describe the adaptation of DPM as an alternative PRIMO computation engine, to validate its performance against penelope and to validate it for some specific cases. Methods DPM was parallelized and modified to perform radiation transport in quadric geometries, which are used to describe linacs, thus allowing the simulation of dynamic treatments. To benchmark the new code versus penelope, both in terms of accuracy of results and simulation time, several tests were performed, namely, irradiation of a multi-layer phantom, irradiation of a water phantom using a collimating pattern defined by the multileaf collimator (MLC), and four clinical cases. The gamma index, with passing criteria of 1 mm/1%, was used to compare the absorbed dose distributions. Clinical cases were compared using a 3-D gamma analysis. Results The percentage of voxels passing the gamma criteria always exceeded 99% for the phantom cases, with the exception of the transport through air, for which dose differences between DPM and penelope were as large as 24%. The corresponding percentage for the clinical cases was larger than 99%. The speedup factor between DPM and penelope ranged from 2.5 ×, for the simulation of the radiation transport through a MLC and the subsequent dose estimation in a water phantom, up to 11.8 × for a lung treatment. A further increase of the computational speed, up to 25 ×, can be obtained in the clinical cases when a voxel size of (2.5 mm)3 is used. Conclusions DPM has been incorporated as an efficient and accurate Monte Carlo engine for dose estimation in PRIMO. It allows the concatenated simulation of the patient-dependent part of the linac and the patient geometry in static and dynamic treatments. The discrepancy observed between DPM and penelope, which is due to an artifact of the cross section interpolation algorithm for low energy electrons in air, does not affect the results in other materials.
Collapse
Affiliation(s)
- Miguel Rodriguez
- Centro Médico Paitilla, Calle 53 y ave. Balboa, Panama City, Panama.,Instituto de Investigaciones Científicas y de Alta Tecnología, INDICASAT-AIP, City of Knowledge, Building 219, Panama City, Panama
| | - Josep Sempau
- Universitat Politècnica de Catalunya, Diagonal 647, Barcelona, E-08028, Spain
| | - Christian Bäumer
- West German Proton Therapy Centre Essen (WPE), Hufelandstraße 55, Essen, D-45147, Germany.,West German Cancer Center (WTZ), Hufelandstraße 55, Essen, D-45147, Germany.,University Hospital Essen, Hufelandstraße 55, Essen, D-45147, Germany.,German Cancer Consortium (DKTK), Hufelandstraße 55, Essen, D-45147, Germany
| | - Beate Timmermann
- West German Proton Therapy Centre Essen (WPE), Hufelandstraße 55, Essen, D-45147, Germany.,West German Cancer Center (WTZ), Hufelandstraße 55, Essen, D-45147, Germany.,University Hospital Essen, Hufelandstraße 55, Essen, D-45147, Germany.,German Cancer Consortium (DKTK), Hufelandstraße 55, Essen, D-45147, Germany.,Department of Particle Therapy, University Hospital Essen, Hufelandstraße 55, Essen, D-45147, Germany
| | - Lorenzo Brualla
- West German Proton Therapy Centre Essen (WPE), Hufelandstraße 55, Essen, D-45147, Germany. .,West German Cancer Center (WTZ), Hufelandstraße 55, Essen, D-45147, Germany. .,University Hospital Essen, Hufelandstraße 55, Essen, D-45147, Germany.
| |
Collapse
|
92
|
Valdes-Cortez C, Niatsetski Y, Perez-Calatayud J, Ballester F, Vijande J. A Monte Carlo-based dosimetric characterization of Esteya®
, an electronic surface brachytherapy unit. Med Phys 2018; 46:356-369. [DOI: 10.1002/mp.13275] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2018] [Revised: 10/07/2018] [Accepted: 10/23/2018] [Indexed: 12/16/2022] Open
Affiliation(s)
- Christian Valdes-Cortez
- Department of Atomic, Molecular and Nuclear Physics; University of Valencia; Burjassot 46100 Spain
- Radiotherapy Department; Centro Oncológico de Antofagasta; Los Pumas 10255 Antofagasta Chile
| | - Yury Niatsetski
- R&D Elekta Brachytherapy; Waardgelder 1 3905 TH Veenendaal The Netherlands
| | - Jose Perez-Calatayud
- Unidad Mixta de Investigación en Radiofísica e Instrumentación Nuclear en Medicina (IRIMED); Instituto de Investigación Sanitaria La Fe (IIS-La Fe)-Universitat de Valencia (UV); E-46026 Valencia Spain
- Radiotherapy Department; La Fe Hospital; E-46026 Valencia Spain
| | - Facundo Ballester
- Department of Atomic, Molecular and Nuclear Physics; University of Valencia; Burjassot 46100 Spain
- Unidad Mixta de Investigación en Radiofísica e Instrumentación Nuclear en Medicina (IRIMED); Instituto de Investigación Sanitaria La Fe (IIS-La Fe)-Universitat de Valencia (UV); Burjassot 46100 Spain
| | - Javier Vijande
- Department of Atomic, Molecular and Nuclear Physics; University of Valencia; Burjassot 46100 Spain
- Unidad Mixta de Investigación en Radiofísica e Instrumentación Nuclear en Medicina (IRIMED); Instituto de Investigación Sanitaria La Fe (IIS-La Fe)-Universitat de Valencia (UV); Burjassot 46100 Spain
| |
Collapse
|
93
|
Zaragoza FJ, Eichmann M, Flühs D, Wittig A, Sauerwein W, Brualla L. Monte Carlo Simulation of the Treatment of Uveal Melanoma Using Measured Heterogeneous 106Ru Plaques. Ocul Oncol Pathol 2018; 5:276-283. [PMID: 31367591 DOI: 10.1159/000492599] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2018] [Revised: 07/31/2018] [Indexed: 11/19/2022] Open
Abstract
Background/Aims Ruthenium plaques are used for the treatment of ocular tumors. The aim of this work is the comparison between simulated absorbed dose distributions tallied in an anthropomorphic phantom, obtained from ideal homogeneous plaques, and real eye plaques in which the actual heterogeneous distribution of <sup>106</sup>Ru was measured. The placement of the plaques with respect to the tumor location was taken into consideration to optimize the effectiveness of the treatment. Methods The generic CCA and CCB, and the specific CCA1364 and CCB1256 <sup>106</sup>Ru eye plaques were modeled with the Monte Carlo code PENELOPE. To compare the suitability of each treatment for an anterior, equatorial and posterior tumor location, cumulative dose-volume histograms for the tumors and structures at risk were calculated. Results Eccentric placements of the plaques, taking into account the inhomogeneities of the emitter map, can substantially reduce the dose delivered to structures at risk while maintaining the prescribed dose at the tumor apex. Conclusions The emitter map distribution of the plaque and the computerized tomography of the patient used in a Monte Carlo simulation allow an accurate determination of the plaque position with respect to the tumor with the potential to reduce the dose to sensitive structures.
Collapse
Affiliation(s)
| | - Marion Eichmann
- Fakultät Physik, Technische Universität Dortmund, Dortmund, Germany
| | - Dirk Flühs
- NCTeam, Strahlenklinik, Universitätsklinikum Essen, Essen, Germany
| | - Andrea Wittig
- Klinik für Strahlentherapie und Radioonkologie, Universitätsklinikum Jena, Jena, Germany
| | | | - Lorenzo Brualla
- West German Proton Therapy Centre Essen (WPE), Essen, Germany
| |
Collapse
|
94
|
Poirier Y, Johnstone CD, Kirkby C. The potential impact of ultrathin filter design on dosimetry and relative biological effectiveness in modern image-guided small animal irradiators. Br J Radiol 2018; 92:20180537. [PMID: 30281330 DOI: 10.1259/bjr.20180537] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE: Modern image-guided small animal irradiators like the Xstrahl Small Animal Radiation Research Platform (SARRP) are designed with ultrathin 0.15 mm Cu filters, which compared with more heavily filtrated traditional cabinet-style biological irradiators, produce X-ray spectra weighted toward lower energies, impacting the dosimetric properties and the relative biological effectiveness (RBE). This study quantifies the effect of ultrathin filter design on relative depth dose profiles, absolute dose output, and RBE using Monte Carlo techniques. METHODS: The percent depth-dose and absolute dose output are calculated using kVDoseCalc and EGSnrc, respectively, while a tally based on the induction of double-strand breaks as a function of electron spectra invoked in PENELOPE is used to estimate the RBE. RESULTS: The RBE increases by >2.4% in the ultrathin filter design compared to a traditional irradiator. Furthermore, minute variations in filter thickness have notable effects on the dosimetric properties of the X-ray beam, increasing the percent depth dose (at 2 cm in water) by + 0.4%/0.01 mm Cu and decreasing absolute dose (at 2 cm depth in water) by -1.8%/0.01 mm Cu for the SARRP. CONCLUSIONS: These results show that modern image-guided irradiators are quite sensitive to small manufacturing variations in filter thickness, and show a small change in RBE compared to traditional X-ray irradiators. ADVANCES IN KNOWLEDGE: We quantify the consequences of ultrathin filter design in modern image-guided biological irradiators on relative and absolute dose, and RBE. Our results show these to be small, but not insignificant, suggesting laboratories transitioning between irradiators should carefully design their radiobiological experiments.
Collapse
Affiliation(s)
- Yannick Poirier
- 1 Department of Radiation Oncology, Division of Translational Radiation Sciences, University of Maryland School of Medicine , Baltimore, MD , USA.,2 Department of Radiation Oncology, Division of Medical Physics, University of Maryland School of Medicine , Baltimore, MD , USA
| | - Christopher Daniel Johnstone
- 1 Department of Radiation Oncology, Division of Translational Radiation Sciences, University of Maryland School of Medicine , Baltimore, MD , USA.,3 Department of Physics and Astronomy, University of Victoria , Victoria, BC , Canada
| | - Charles Kirkby
- 4 Department of Medical Physics, Jack Ady Cancer Center , Lethbridge, AB , Canada.,5 Department of Physics and Astronomy, University of Calgary , Calgary, AB , Canada.,6 Department of Oncology, University of Calgary , Calgary, AB , Canada
| |
Collapse
|
95
|
Garnier N, Amblard R, Villeneuve R, Haykal R, Ortholan C, Colin P, Gérard A, Belhomme S, Mady F, Benabdesselam M, Serrano B. Detectors assessment for stereotactic radiosurgery with cones. J Appl Clin Med Phys 2018; 19:88-98. [PMID: 30216702 PMCID: PMC6236831 DOI: 10.1002/acm2.12449] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2018] [Revised: 08/06/2018] [Accepted: 08/16/2018] [Indexed: 12/03/2022] Open
Abstract
The purpose of this work is to assess eight detectors performance for output factor (OF), percent depth dose (PDD), and beam profiles in a 6‐MV Clinac stereotactic radiosurgery mode for cone irradiation using Monte Carlo simulation as reference. Cones with diameters comprised between 30 and 4 mm have been studied. The evaluated detectors were ionization chambers: pinpoint and pinpoint 3D, diodes: SRS, P and E, Edge, MicroDiamond and EBT3 radiochromic films. The results showed that pinpoints underestimate OF up to −2.3% for cone diameters ≥10 mm and down to −12% for smaller cones. Both nonshielded (SRS and E) and shielded diodes (P and Edge) overestimate the OF respectively up to 3.3% and 5.2% for cone diameters ≥10 mm and in both cases more than 7% for smaller cones. MicroDiamond slightly overestimates the OF, 3.7% for all the cones and EBT3 film is the closest to Monte Carlo with maximum difference of ±1% whatever the cone size is. For the profiles and the PDD, particularly for the small cones, the size of the detector predominates. All diodes and EBT3 agree with the simulation within ±0.2 mm for beam profiles determination. For PDD curve all the active detectors response agree with simulation up to 1% for all the cones. EBT3 is the more accurate detector for beam profiles and OF determinations of stereotactic cones but it is restrictive to use. Due to respectively inappropriate size of the sensitive volume and composition, pinpoints and diodes do not seem appropriate without OF corrective factors below 10 mm diameter cone. MicroDiamond appears to be the best detector for OF determination regardless all cones. For off‐axis measurements, the size of the detector predominates and for PDD all detectors give promising results.
Collapse
Affiliation(s)
- Nicolas Garnier
- Medical Physics Department, Princess Grace Hospital Center, Monaco, Monaco.,Institut de Physique de Nice, Côte d'Azur University, Parc Valrose, Nice, France
| | - Régis Amblard
- Medical Physics Department, Princess Grace Hospital Center, Monaco, Monaco
| | - Rémy Villeneuve
- Medical Physics Department, Princess Grace Hospital Center, Monaco, Monaco
| | - Rodolphe Haykal
- Medical Physics Department, Princess Grace Hospital Center, Monaco, Monaco
| | - Cécile Ortholan
- Radiotherapy Department, Princess Grace Hospital Center, Monaco, Monaco
| | - Philippe Colin
- Radiotherapy Department, Princess Grace Hospital Center, Monaco, Monaco
| | - Anaïs Gérard
- Medical Physics Department, Centre Antoine Lacassagne, Nice, France
| | - Sarah Belhomme
- Medical Physics Department, Institut Bergonié, Bordeaux, France
| | - Franck Mady
- Institut de Physique de Nice, Côte d'Azur University, Parc Valrose, Nice, France
| | - Mourad Benabdesselam
- Institut de Physique de Nice, Côte d'Azur University, Parc Valrose, Nice, France
| | - Benjamin Serrano
- Medical Physics Department, Princess Grace Hospital Center, Monaco, Monaco
| |
Collapse
|
96
|
Chung JP, Seong YM, Kim TY, Choi Y, Kim TH, Choi HJ, Min CH, Benmakhlouf H, Chun KJ, Chung HT. Development of a PMMA phantom as a practical alternative for quality control of gamma knife® dosimetry. Radiat Oncol 2018; 13:176. [PMID: 30217160 PMCID: PMC6137750 DOI: 10.1186/s13014-018-1117-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2018] [Accepted: 08/27/2018] [Indexed: 11/17/2022] Open
Abstract
BACKGROUND To measure the absorbed dose rate to water and penumbra of a Gamma Knife® (GK) using a polymethyl metacrylate (PMMA) phantom. METHODS A multi-purpose PMMA phantom was developed to measure the absorbed dose rate to water and the dose distribution of a GK. The phantom consists of a hemispherical outer phantom, one exchangeable cylindrical chamber-hosting inner phantom, and two film-hosting inner phantoms. The radius of the phantom was determined considering the electron density of the PMMA such that it corresponds to 8 g/cm2 water depth, which is the reference depth of the absorbed dose measurement of GK. The absorbed dose rate to water was measured with a PTW TN31010 chamber, and the dose distributions were measured with radiochromic films at the calibration center of a patient positioning system of a GK Perfexion. A spherical water-filled phantom with the same water equivalent depth was constructed as a reference phantom. The dose rate to water and dose distributions at the center of a circular field delimited by a 16-mm collimator were measured with the PMMA phantom at six GK Perfexion sites. RESULTS The radius of the PMMA phantom was determined to be 6.93 cm, corresponding to equivalent water depth of 8 g/cm2. The absorbed dose rate to water was measured with the PMMA phantom, the spherical water-filled phantom and a commercial solid water phantom. The measured dose rate with the PMMA phantom was 1.2% and 1.8% higher than those measured with the spherical water-filled phantom and the solid water phantom, respectively. These differences can be explained by the scattered photon contribution of PMMA off incoming 60Co gamma-rays to the dose rate. The average full width half maximum and penumbra values measured with the PMMA phantom showed reasonable agreement with two calculated values, one at the center of the PMMA phantom (LGP6.93) and other at the center of a water sphere with a radius of 8 cm (LGP8.0) given by Leksell Gamma Plan using the TMR10 algorithm. CONCLUSIONS A PMMA phantom constructed in this study to measure the absorbed dose rates to water and dose distributions of a GK represents an acceptable and practical alternative for GK dosimetry considering its cost-effectiveness and ease of handling.
Collapse
Affiliation(s)
- Jae Pil Chung
- Center for Ionizing Radiation, Division of Metrology for Quality of Life, Korea Research Institute of Standards and Science, 267 Gajeong-ro, Yuseong-gu, Daejon, 34311 Korea
| | - Young Min Seong
- Center for Ionizing Radiation, Division of Metrology for Quality of Life, Korea Research Institute of Standards and Science, 267 Gajeong-ro, Yuseong-gu, Daejon, 34311 Korea
| | - Tae Yeon Kim
- Department of Accelerator Science, Korea University Sejong Campus, 2511 Sejong-ro, Sejong, 30019 Korea
| | - Yona Choi
- Department of Accelerator Science, Korea University Sejong Campus, 2511 Sejong-ro, Sejong, 30019 Korea
| | - Tae Hoon Kim
- Department of Nuclear Engineering, Hanyang University College of Engineering, Seoul, 04763 Korea
| | - Hyun Joon Choi
- Department of Radiation Convergence Engineering, Yonsei University, 1 Yeonsedae-gil, Heungeop-myeon, Wonju, 26493 Korea
| | - Chul Hee Min
- Department of Radiation Convergence Engineering, Yonsei University, 1 Yeonsedae-gil, Heungeop-myeon, Wonju, 26493 Korea
| | - Hamza Benmakhlouf
- Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, SE-17176 Stockholm, Sweden
| | - Kook Jin Chun
- Department of Accelerator Science, Korea University Sejong Campus, 2511 Sejong-ro, Sejong, 30019 Korea
| | - Hyun-Tai Chung
- Department of Neurosurgery, Seoul National University College of Medicine, 101 Daehak-ro Jongno-gu, Seoul, 03080 Korea
| |
Collapse
|
97
|
Hermida–López M, Sánchez–Artuñedo D, Calvo–Ortega JF. PRIMO Monte Carlo software benchmarked against a reference dosimetry dataset for 6 MV photon beams from Varian linacs. Radiat Oncol 2018; 13:144. [PMID: 30086767 PMCID: PMC6081807 DOI: 10.1186/s13014-018-1076-0] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2018] [Accepted: 07/11/2018] [Indexed: 11/17/2022] Open
Abstract
BACKGROUND The software PRIMO for the Monte Carlo simulation of radiotherapy linacs could potentially act as a independent calculation system to verify the calculations of treatment planning systems. We investigated the suitability of the PRIMO default beam parameters to produce accurate dosimetric results for 6 MV photon beams from Varian Clinac 2100 linacs and 6 MV flattening-filter-free photon beams from Varian TrueBeam linacs. METHODS Simulation results with the DPM algorithm were benchmarked against a published reference dosimetry dataset based on point measurements of 25 dosimetric parameters on a large series of linacs. Studied parameters (for several field sizes and depths) were: PDD, off-axis ratios, and output factors for open fields and IMRT/SBRT-style fields. For the latter, the output factors were also determined with radiochromic film and with a small-sized ionization chamber. Benchmark data, PRIMO simulation results and our experimental results were compared. RESULTS PDD, off-axis ratios, and open-field output factors obtained from the simulations with the PRIMO default beam parameters agreed with the benchmark data within 2.4% for Clinac 2100, and within 1.3% for TrueBeam. Higher differences were found for IMRT/SBRT-style output factors: up to 2.8% for Clinac 2100, and up to 3.3% for TrueBeam. Experimental output factors agreed with benchmark data within 1.0% (ionization chamber) and within 1.9% (radiochromic film). CONCLUSIONS PRIMO default initial beam parameters for 6 MV photon beams from Varian Clinac 2100 linacs and 6 MV FFF photon beams from Varian TrueBeam linacs allowed agreement within 3.3% with a dosimetry database based on measurements of a high number of linacs. This finding represents a first step in the validation of PRIMO for the independent verification of radiotherapy plans.
Collapse
Affiliation(s)
- Marcelino Hermida–López
- Servei de Física i Protecció Radiològica. Hospital Universitari Vall d’Hebron, Pg. Vall d’Hebron, 119–129, Barcelona, 08035 Spain
| | - David Sánchez–Artuñedo
- Servei de Física i Protecció Radiològica. Hospital Universitari Vall d’Hebron, Pg. Vall d’Hebron, 119–129, Barcelona, 08035 Spain
| | - Juan Francisco Calvo–Ortega
- Servicio de Oncología Radioterápica, Hospital Quirónsalud Barcelona, Pza. Alfonso Comín, 5, Barcelona, 08023 Spain
- Servicio de Oncología Radioterápica, Hospital Universitario Dexeus, C./ Sabino Arana, 5-19, Barcelona, 08028 Spain
| |
Collapse
|
98
|
Prado A, Lozano FR, Cabello E, Díaz R, Rot MJ. Dosimetric characterization of a 5 mm diameter BrainLab cone for radiosurgery. Biomed Phys Eng Express 2018. [DOI: 10.1088/2057-1976/aace50] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
99
|
Fogliata A, Stravato A, Reggiori G, Tomatis S, Würfel J, Scorsetti M, Cozzi L. Collimator scatter factor: Monte Carlo and in-air measurements approaches. Radiat Oncol 2018; 13:126. [PMID: 29996873 PMCID: PMC6042423 DOI: 10.1186/s13014-018-1070-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2018] [Accepted: 06/29/2018] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Linac output as a function of field sizes has a phantom and a head scatter component. This last term can be measured in-air with appropriate build-up ensuring a complete electron equilibrium and the absence of the contaminant electrons. Equilibrium conditions could be achieved using a build-up cap or a mini-phantom. Monte Carlo simulations in a virtual phantom mimicking a mini-phantom were analysed with the aim of better understanding the setup conditions for measuring the collimator scatter factor that is the head scatter component of the linac output factors. METHODS Beams of 6 and 15 MV from a TrueBeam, with size from 4 × 4 to 40 × 40 cm2 were simulated in cylindrical acrylic phantoms 20 cm long, of different diameters, from 0.5 to 4 cm, with the cylinder axis coincident with the beam central axis. The PRIMO package, based on PENELOPE Monte Carlo code, was used. The phase-space files for a Varian TrueBeam linac, provided by the linac vendor, were used for the linac head simulation. Depth dose curves were analysed, and collimator scatter factors estimated at different depth in the different phantom conditions. Additionally, in-air measurements using acyrilic and brass build-up caps, as well as acrylic mini-phantom were acquired for 6 and 18 MV beams from a Varian Clinac DHX. RESULTS The depth dose curves along the cylinders were compared, showing, in each phantom, very similar curves for all analysed field sizes, proving the correctness in estimating the collimator scatter factor in the mini-phantom, provided to position the detector to a sufficient depth to exclude electron contamination. The results were confirmed by the measurements, where the acrylic build-up cap showed to be inadequate to properly estimate the collimator scatter factors, while the mini-phantom and the brass caps gave reasonable measurements. CONCLUSION A better understanding of the beam characteristics inside a virtual mini-phantom through the analysis of depth dose curves, showed the critical points of using the acrylic build-up cap, and suggested the use of the mini-phantom for the collimator scatter factor measurements in the medium-large field size range.
Collapse
Affiliation(s)
- A Fogliata
- Radiotherapy and Radiosurgery Department, Humanitas Research Hospital and Cancer Center, Milan-Rozzano, Italy.
| | - A Stravato
- Radiotherapy and Radiosurgery Department, Humanitas Research Hospital and Cancer Center, Milan-Rozzano, Italy
| | - G Reggiori
- Radiotherapy and Radiosurgery Department, Humanitas Research Hospital and Cancer Center, Milan-Rozzano, Italy
| | - S Tomatis
- Radiotherapy and Radiosurgery Department, Humanitas Research Hospital and Cancer Center, Milan-Rozzano, Italy
| | - J Würfel
- PTW-Freiburg GmbH, Freiburg, Germany
| | - M Scorsetti
- Radiotherapy and Radiosurgery Department, Humanitas Research Hospital and Cancer Center, Milan-Rozzano, Italy.,Biomedical Science Faculty, Humanitas University, Milan-Rozzano, Italy
| | - L Cozzi
- Radiotherapy and Radiosurgery Department, Humanitas Research Hospital and Cancer Center, Milan-Rozzano, Italy.,Biomedical Science Faculty, Humanitas University, Milan-Rozzano, Italy
| |
Collapse
|
100
|
Performance of different theories for the angular distribution of bremsstrahlung produced by keV electrons incident upon a target. Radiat Phys Chem Oxf Engl 1993 2018. [DOI: 10.1016/j.radphyschem.2018.02.009] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|