Abstract
Management of peripartum heart disease in the intensive care unit requires optimization of maternal hemodynamics and maintenance of fetal perfusion. This requires fetal monitoring and should address the parturient's oxygen saturation, hemoglobin, and cardiac output as it relates to uterine blood flow. Pharmacologic strategies have limited evidence pertaining to hemodynamic stabilization and fetal perfusion. There is some evidence that surgical management of critical mitral stenosis should be percutaneous when possible because cardiac bypass is associated with increased fetal mortality. Fetal monitoring strategies should address central organ perfusion because peripheral scalp pH has not been associated with improved fetal outcomes.
Collapse
Affiliation(s)
- Huayong Hu
- Department of Anesthesiology, Yale New Haven Hospital, New Haven, CT, USA.
| | - Ioana Pasca
- Department of Anesthesiology, Loma Linda University Medical Center, Loma Linda, CA, USA
| |
Collapse
|
52
|
Rimmer S, Roberts SA, Heazell AEP. Cervical dilatation and grade of doctor affects the interval between decision and result of fetal scalp blood sampling in labour. J Matern Fetal Neonatal Med 2015; 29:2671-4. [PMID: 26399279 DOI: 10.3109/14767058.2015.1099157] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Fetal scalp blood sampling (FSBS) is used to provide information regarding fetal acid-base status during labour. This study assessed the interval between the decision to perform the procedure and obtaining the result and evaluated whether it is affected by cervical dilatation or the experience of the doctor. The median time for FSBS was 10 min. When cervical dilatation was ≤4 cm samples took approximately 30% longer to obtain. After adjustment for dilation, there were no significant differences between different grades of doctors. FSBS is shorter than previously reported; clinicians should be aware that procedures in early labour take longer to complete.
Collapse
Affiliation(s)
- Stephanie Rimmer
- a Maternal and Fetal Health Research Centre, Institute of Human Development, University of Manchester , Manchester , UK .,b St. Mary's Hospital, Central Manchester University Hospitals NHS Foundation Trust, Manchester Academic Health Science Centre , Manchester , UK , and
| | - Stephen A Roberts
- c Centre for Biostatistics, Institute of Population Health, Manchester Academic Health Science Centre, University of Manchester , Manchester , UK
| | - Alexander E P Heazell
- a Maternal and Fetal Health Research Centre, Institute of Human Development, University of Manchester , Manchester , UK .,b St. Mary's Hospital, Central Manchester University Hospitals NHS Foundation Trust, Manchester Academic Health Science Centre , Manchester , UK , and
| |
Collapse
|
53
|
Jenniskens K, Janssen PA. Newborn outcomes in british columbia after caesarean section for non-reassuring fetal status. JOURNAL OF OBSTETRICS AND GYNAECOLOGY CANADA 2015; 37:207-213. [PMID: 26001867 DOI: 10.1016/s1701-2163(15)30306-6] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
OBJECTIVE To assess the incidence in British Columbia of severe morbidity in neonates delivered by Caesarean section for non-reassuring fetal status, and to examine the accuracy of Apgar score and umbilical cord gas values in predicting severe neonatal morbidity. METHODS We assessed rates of hypoxic ischemic encephalopathy, NICU admission, and ventilator days, individually and as a composite outcome with neonatal death, among a total of 8466 term singletons delivered by Caesarean section for non-reassuring fetal status between January 1, 2007, and December 31, 2011. We calculated the predictive accuracy of Apgar scores and umbilical cord blood gas values using the area under the receiver operating characteristic (ROC) curve and the sensitivity and specificity for each outcome. RESULTS The incidence of Apgar score at one minute < 4 was 8.0%, and for Apgar score at five minutes < 4 it was 0.6%. The incidence of umbilical cord pH < 7.10 was 6.5%, and for base-excess < -12 it was 2.9%. Apgar score at one minute < 7 had the greatest predictive accuracy for the composite outcome (81% for both sensitivity and specificity). The area under the ROC curve for Apgar score at one minute and at five minutes, umbilical cord pH, and base-excess was 0.87, 0.86, 0.76, and 0.78, respectively. CONCLUSION The incidence of abnormal Apgar score and abnormal umbilical cord gas values is very low among neonates in British Columbia delivered by Caesarean section for non-reassuring fetal status. Apgar score at one minute < 7 is a good predictor of severe neonatal morbidity. Electronic fetal monitoring remains a non-specific method for detection of fetal compromise in the intrapartum period.
Collapse
Affiliation(s)
- Kevin Jenniskens
- Radboud University Nijmegen Medical Centre, Institute for Health Sciences, Nijmegen, The Netherlands; School of Population and Public Health, University of British Columbia, Vancouver BC
| | - Patricia A Janssen
- School of Population and Public Health, University of British Columbia, Vancouver BC; Child and Family Research Institute, Vancouver BC
| |
Collapse
|
54
|
Rørbye C, Perslev A, Nickelsen C. Lactate versus pH levels in fetal scalp blood during labor--using the Lactate Scout System. J Matern Fetal Neonatal Med 2015; 29:1200-4. [PMID: 26004985 DOI: 10.3109/14767058.2015.1045863] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
OBJECTIVE To assess if lactate measured with the Scout Lactate System is a reliable alternative to pH in intrapartum monitoring of the fetus. METHODS A prospective study analyzing (1) the correlation between scalp lactate measured by the Scout Lactate System and the Automatic Blood Laboratory (ABL), (2) the correlation between lactate and pH measured in scalp blood and (3) the correlation between fetal scalp lactate and umbilical cord SBE. The sensitivity/specificity and positive/negative predictive values of lactate in predicting low pH were analyzed and expressed as Receiver Operating Curves (ROC). RESULTS Lactate measured by the Scout Lactate System and the ABL correlated well (r(2)=0.85). Both lactate and pH were measured in 1009 scalp blood samples. The sensitivity and specificity of lactate ≥ 4.8 mmol/l in predicting a pH <7.20 were 0.63 and 0.85, respectively. The correlation between scalp lactate measured within 15 min prior to delivery and the umbilical cord SBE was low. CONCLUSION Monitoring non-reassuring deliveries with scalp lactate instead of pH would have resulted in more (155 instead of 56) instrumental deliveries with no decrease in newborns with severe metabolic acidosis.
Collapse
Affiliation(s)
- Christina Rørbye
- a Department of Obstetrics and Gynecology , University of Copenhagen, Hvidovre Hospital , Hvidovre , Denmark
| | - Anette Perslev
- a Department of Obstetrics and Gynecology , University of Copenhagen, Hvidovre Hospital , Hvidovre , Denmark
| | - Carsten Nickelsen
- a Department of Obstetrics and Gynecology , University of Copenhagen, Hvidovre Hospital , Hvidovre , Denmark
| |
Collapse
|
55
|
East CE, Leader LR, Sheehan P, Henshall NE, Colditz PB, Lau R. Intrapartum fetal scalp lactate sampling for fetal assessment in the presence of a non-reassuring fetal heart rate trace. Cochrane Database Syst Rev 2015; 2015:CD006174. [PMID: 25929461 PMCID: PMC10823414 DOI: 10.1002/14651858.cd006174.pub3] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND Fetal scalp blood sampling for lactate estimation may be considered following identification of an abnormal or non-reassuring fetal heart rate pattern. The smaller volume of blood required for this test, compared with the more traditional pH estimation, may improve sampling rates. The appropriate use of this practice mandates systematic review of its safety and clinical effectiveness prior to widespread introduction. OBJECTIVES To evaluate the effectiveness and risks of fetal scalp lactate sampling in the assessment of fetal well-being during labour, compared with no testing or alternative testing. SEARCH METHODS We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (31 January 2015). SELECTION CRITERIA All published and unpublished randomised and quasi-randomised trials that compared fetal scalp lactate testing with no testing or alternative testing to evaluate fetal status in the presence of a non-reassuring cardiotocograph during labour. DATA COLLECTION AND ANALYSIS We used the standard methodological procedures of the Cochrane Pregnancy and Childbirth Group. Two review authors independently assessed the studies. MAIN RESULTS The search identified two completed randomised controlled trials (RCTs) and two ongoing trials. The two published RCTs considered outcomes for 3348 mother-baby pairs allocated to either lactate or pH estimation of fetal blood samples when clinically indicated in labour. Overall, the published RCTs were of low or unclear risk of bias. There was a high risk of performance bias, because it would not have been feasible to blind clinicians or participants.No statistically significant between-group differences were found for neonatal encephalopathy (risk ratio (RR) 1.00, 95% confidence interval (CI) 0.32 to 3.09, one study, 2992 infants) or death. No studies reported neonatal seizures. We had planned to report death with other morbidities, for example, neonatal encephalopathy; however, the data were not available in a format suitable for this, therefore death due to congenital abnormality was considered alone. The three reported neonatal deaths occurred in babies with diaphragmatic hernias (n = 2) or congenital cardiac fibrosis (n = 1). All three babies had been randomised to the pH group and were not acidaemic at birth.There were no statistically significant differences for any of the pre-specified secondary fetal/neonatal/infant outcomes for which data were available. This included low Apgar score at five minutes (RR 1.13, 95% CI 0.76 to 1.68, two studies, 3319 infants) and admission to neonatal intensive care units (RR 1.02, 95% CI 0.83 to 1.25, one study, 2992 infants), or metabolic acidaemia (RR 0.91, 95% CI 0.60 to 1.36, one study, 2675 infants) considered within the studies, either overall or where data were available for those where fetal blood sampling had occurred within 60 minutes of delivery.Similar proportions of fetuses underwent additional tests to further evaluate well-being during labour, including scalp pH if in the lactate group or scalp lactate if in the pH group (RR 0.22, 95% CI 0.04 to 1.30, two studies, 3333 infants;Tau² 1.00, I² = 58%). Fetal blood sampling attempts for lactate and pH estimation were successful in 98.7% and 79.4% of procedures respectively in the one study that reported this outcome.There were no significant between-group differences in mode of birth or operative birth for non-reassuring fetal status, either for all women, or within the group where the fetal blood sample had been taken within 60 minutes of delivery (for example, caesarean section for all enrolled, RR 1.09, 95% CI 0.97 to 1.22, two studies, 3319 women; operative delivery for non-reassuring fetal status for all enrolled RR 1.02, 95% CI 0.93 to 1.11, one study, 2992 women).Neither study reported on adverse effects of fetal scalp lacerations or maternal anxiety. AUTHORS' CONCLUSIONS When further testing to assess fetal well-being in labour is indicated, fetal scalp blood lactate estimation is more likely to be successfully undertaken than pH estimation. Further studies may consider subgroup analysis by gestational age, the stage of labour and sampling within a prolonged second stage of labour. Additionally, we await the findings from the ongoing studies that compare allocation to no fetal blood sample with sampling for lactate and address longer-term neonatal outcomes, maternal satisfaction with intrapartum fetal monitoring and an economic analysis.
Collapse
Affiliation(s)
- Christine E East
- Monash University/Monash HealthSchool of Nursing and Midwifery/Maternity Services246 Clayton RoadClaytonVictoriaAustralia3168
| | - Leo R Leader
- University of New South WalesWomen's and Children's HealthRoyal Hospital for WomenBarker StreetRandwickNSWAustralia2031
| | - Penelope Sheehan
- University of MelbourneDepartment of Obstetrics and GynaecologyPregnancy Research Centre, 7th Floor, Royal Women's Hospital20 Flemington Road, ParkvilleMelbourneVictoriaAustralia3052
| | - Naomi E Henshall
- Royal Hospital for WomenDelivery SuiteRandwickNew South WalesAustralia
| | - Paul B Colditz
- The University of Queensland, Royal Brisbane & Women's HospitalPerinatal Research CentreButterfield StreetHerstonQueenslandAustralia4029
| | - Rosalind Lau
- Monash UniversitySchool of Nursing and MidwiferyWellington RoadClaytonVictoriaAustralia3800
| | | |
Collapse
|
56
|
Prior T, Kumar S. Expert review--identification of intra-partum fetal compromise. Eur J Obstet Gynecol Reprod Biol 2015; 190:1-6. [PMID: 25917435 DOI: 10.1016/j.ejogrb.2015.04.002] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2014] [Revised: 01/31/2015] [Accepted: 04/07/2015] [Indexed: 09/30/2022]
Abstract
Whilst most cases of cerebral palsy occur as a consequence of an ante-natal insult, a significant proportion, particularly in the term fetus, are attributable to intra-partum hypoxia. Intra-partum monitoring using continuous fetal heart rate assessment has led to an increased incidence of operative delivery without a concurrent reduction in the incidence of cerebral palsy. Despite this, birth asphyxia remains the strongest and most consistent risk factor for cerebral palsy in term infants. This review evaluates current intra-partum monitoring techniques as well as alternative approaches aimed at better identification of the fetus at risk of compromise in labour.
Collapse
Affiliation(s)
- Tomas Prior
- Centre for Fetal Care, Queen Charlotte's and Chelsea Hospital, Du Cane Road, London W12 0HS, UK; Institute for Reproductive and Developmental Biology, Imperial College London, London W12 0HS, UK
| | - Sailesh Kumar
- Centre for Fetal Care, Queen Charlotte's and Chelsea Hospital, Du Cane Road, London W12 0HS, UK; Institute for Reproductive and Developmental Biology, Imperial College London, London W12 0HS, UK; Mater Research Institute/University of Queensland, Aubigny Place, Raymond Terrace, South Brisbane, QLD 4101, Australia.
| |
Collapse
|
57
|
Labrecque L, Provençal M, Caqueret A, Wo BL, Bujold E, Larivière F, Bédard MJ. Correlation of cord blood pH, base excess, and lactate concentration measured with a portable device for identifying fetal acidosis. JOURNAL OF OBSTETRICS AND GYNAECOLOGY CANADA 2015; 36:598-604. [PMID: 25184978 DOI: 10.1016/s1701-2163(15)30539-9] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE To determine the effectiveness of portable lactate analyzers in identifying fetal acidosis by correlating arterial and venous lactate values from umbilical cord blood with lactate, pH, and base excess measurements from central laboratory analyzers. METHODS We performed a prospective study using arterial and venous cord blood from 52 women with a singleton fetus delivered at term. We evaluated the correlation between the cord blood lactate concentration measured using two of the same portable devices (Lactate Plus, Nova Biomedical) with the result from a central laboratory analyzer. Analyses of the correlation between arterial lactate concentration measured on the portable device with arterial pH and base excess were then performed. RESULTS We observed a median arterial pH of 7.24 (range 7.05 to 7.35) and a median arterial lactate concentration of 3.7 mmol/L (range 1.7 to 8.8 mmol/L). An excellent correlation was observed between lactate concentrations measured by the two portable devices (arterial R² = 0.98 and venous R² = 0.98), and between the portable device and the central laboratory analyzer (arterial R² = 0.94 and venous R² = 0.95). In our population, the optimal cut-offs to predict a pH < 7.20 or a base excess > -8.0 mmol/L were a lactate concentration of 4.9 mmol/L and 5.3 mmol/L, respectively, according to receiver operator characteristic analysis. With a lactate concentration > 4.9 mmol/L, the portable device had a sensitivity of 82% and a specificity of 90% to identify samples with an arterial pH < 7.20. CONCLUSION Cord blood lactate concentration measured with a portable device is a good predictor of cord blood base excess and pH. Future studies should be designed to correlate scalp blood lactate measurements with clinical outcomes.
Collapse
Affiliation(s)
- Lyne Labrecque
- Department of Biochemistry, Centre hospitalier de l'Université de Montréal, Montreal QC
| | - Mathieu Provençal
- Department of Biochemistry, Centre hospitalier de l'Université de Montréal, Montreal QC
| | - Aurore Caqueret
- Department of Biochemistry, Centre hospitalier de l'Université de Montréal, Montreal QC
| | - Bi Lan Wo
- Department of Obstetrics and Gynecology, Centre hospitalier de l'Université de Montréal, Montreal QC
| | - Emmanuel Bujold
- Department of Obstetrics and Gynecology, Faculty of Medicine, Université Laval, Quebec QC
| | - François Larivière
- Department of Biochemistry, Centre hospitalier de l'Université de Montréal, Montreal QC
| | - Marie-Josée Bédard
- Department of Obstetrics and Gynecology, Centre hospitalier de l'Université de Montréal, Montreal QC
| |
Collapse
|
58
|
Neonatal outcome and delivery mode in labors with repetitive fetal scalp blood sampling. Eur J Obstet Gynecol Reprod Biol 2015; 184:97-102. [DOI: 10.1016/j.ejogrb.2014.11.012] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2014] [Revised: 10/21/2014] [Accepted: 11/11/2014] [Indexed: 10/24/2022]
|
59
|
Bowler T, Beckmann M. Comparing fetal scalp lactate and umbilical cord arterial blood gas values. Aust N Z J Obstet Gynaecol 2014; 54:79-83. [PMID: 24471849 DOI: 10.1111/ajo.12144] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2013] [Accepted: 09/10/2013] [Indexed: 11/30/2022]
Abstract
BACKGROUND Fetal scalp lactate has been shown to be as effective as scalp pH in predicting fetal outcomes. However, there is limited clinical evidence to demonstrate a strong correlation with fetal acidaemia at birth. AIMS To compare the diagnostic accuracy of fetal scalp lactate and umbilical cord arterial blood gas values sampling, as it is used in clinical practice. METHODS A retrospective cohort study was performed on 661 term (≥37 weeks) births where a fetal scalp lactate sample was taken during labour. Cases were excluded where either the lactate was taken greater than 1 h prior to delivery, incomplete cord gas analyses were available, or a sentinel hypoxic event occurred prior to delivery. The final data set included 229 microvolume scalp lactate measurements which were compared with neonatal paired cord blood gas values taken at delivery. RESULTS A fetal scalp lactate measurement of ≥4.8 mmol/L had a positive predictive value (PPV) of 1% and a negative predictive value (NPV) of 100% in predicting umbilical artery pH ≤7.00, and a PPV of 5% and a NPV of 98% in predicting umbilical artery pH ≤7.10. The sensitivity and specificity for these values were 100%, 23% and 90%, 23%, respectively. CONCLUSIONS Fetal scalp lactate microsampling has a strong negative predictive value for fetal acidaemia at birth.
Collapse
Affiliation(s)
- Thea Bowler
- Department of Obstetrics and Gynaecology, Mater Services, Brisbane, Australia
| | | |
Collapse
|
60
|
Kessler J, Moster D, Albrechtsen S. Intrapartum monitoring with cardiotocography and ST-waveform analysis in breech presentation: an observational study. BJOG 2014; 122:528-35. [DOI: 10.1111/1471-0528.12989] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/29/2014] [Indexed: 11/28/2022]
Affiliation(s)
- J Kessler
- Department of Obstetrics and Gynaecology; Haukeland University Hospital; Bergen Norway
- Department of Clinical Science; Research Group for Pregnancy, Fetal Development and Birth; University of Bergen; Bergen Norway
| | - D Moster
- Department of Health Registries; Norwegian Institute of Public Health; Bergen Norway
- Department of Paediatrics; Haukeland University Hospital; Bergen Norway
- Department of Global Public Health and Primary Care; University of Bergen; Bergen Norway
| | - S Albrechtsen
- Department of Obstetrics and Gynaecology; Haukeland University Hospital; Bergen Norway
- Department of Clinical Science; Research Group for Pregnancy, Fetal Development and Birth; University of Bergen; Bergen Norway
| |
Collapse
|
61
|
Chandraharan E, Wiberg N. Fetal scalp blood sampling during labor: an appraisal of the physiological basis and scientific evidence. Acta Obstet Gynecol Scand 2014; 93:544-7. [DOI: 10.1111/aogs.12416] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2014] [Accepted: 05/01/2014] [Indexed: 11/29/2022]
Affiliation(s)
| | - Nana Wiberg
- Department of Obstetrics and Gynecology; Herlev Hospital; Copenhagen Denmark
- Faculty of Medicine; Lund University; Lund Sweden
| |
Collapse
|
62
|
Elmstedt NN, Johnson JJ, Lind BB, Ferm-Widlund KK, Herling LL, Westgren MM, Brodin LÅL. Reference values for fetal tissue velocity imaging and a new approach to evaluate fetal myocardial function. Cardiovasc Ultrasound 2013; 11:29. [PMID: 23947791 PMCID: PMC3751897 DOI: 10.1186/1476-7120-11-29] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/30/2013] [Accepted: 08/09/2013] [Indexed: 11/10/2022] Open
Abstract
OBJECTIVES Myocardial function can be evaluated using color-coded tissue velocity imaging (TVI) to analyze the longitudinal myocardial velocity profile, and by expressing the motion of the atrioventricular plane during a cardiac cycle as coordinated events in the cardiac state diagram (CSD). The objective of this study was to establish gestational age specific reference values for fetal TVI measurements and to introduce the CSD as a potential aid in fetal myocardial evaluation. METHODS TVI recordings from 125 healthy fetuses, at 18 to 42 weeks of gestation, were performed with the transducer perpendicular to the apex to provide a four-chamber view. The myocardial velocity data was extracted from the basal segment of septum as well as the left and right ventricular free wall for subsequent offline analysis. RESULTS During a cardiac cycle the longitudinal peak velocities of septum increased with gestational age, as did the peak velocities of the left and right ventricular free wall, except for the peak velocity of post ejection. The duration of rapid filling and atrial contraction increased during pregnancy while the duration of post ejection decreased. The duration of pre ejection and ventricular ejection did not change significantly with gestational age. CONCLUSION Evaluating fetal systolic and diastolic performance using TVI together with CSD could contribute to increase the knowledge and understanding of fetal myocardial function and dysfunction. The pre and post ejection phases are the variables most likely to indicate fetuses with abnormal myocardial function.
Collapse
|
63
|
Su TY, Reece M, Chua SC. Lactate study using umbilical cord blood: agreement between Lactate Pro hand-held devices with blood gas analyser and evaluation of lactate stability over time. Aust N Z J Obstet Gynaecol 2013; 53:375-80. [PMID: 23550587 DOI: 10.1111/ajo.12081] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2012] [Accepted: 02/16/2013] [Indexed: 11/28/2022]
Abstract
BACKGROUND Lactate measurements have become increasingly preferred over pH analysis in the evaluation of fetal acidaemia in labour. In a busy labour ward, often the umbilical cord may be sampled late and as a result yield unreliable lactate values. AIM To investigate the agreement of hand-held device Lactate Pro with a reference method blood gas analyser and evaluate the stability of umbilical cord lactate values over time. METHODS Prospective study carried out at elective caesarean section. Sixteen umbilical cords were double clamped immediately after delivery with paired arterial and venous blood samples collected by an independent researcher, at varying time intervals, and processed by two Lactate Pro devices and a reference method blood gas analyser. RESULTS A significant difference of -0.41 to 0.10 mmol/L was found when different groups of Lactate Pro devices were compared with blood gas analyser at lactate values up to 5.70 mmol/L, with average lactate value of 2.45 mmol/L. Over time, there is progressive rise in lactate samples obtained from the umbilical cord. CONCLUSION Lactate Pro devices have a significant difference, but when used in clinical practice on cord blood after delivery, this is unlikely to be meaningful. In intrapartum fetal surveillance, a systematic overestimation might lead to unnecessary intervention. It is possible to retrospectively predict the likely level of lactate at birth in delayed cord samples.
Collapse
Affiliation(s)
- Tina Y Su
- Obstetrics and Gynaecology, Westmead Hospital, Sydney, New South Wales, Australia.
| | | | | |
Collapse
|
64
|
Hall B, Iwasenko J, Moriatis M, Rawlinson WD, Tracy MB, Tracy SK. A pilot study to determine the feasibility of collecting amniotic fluid samples from women during labour and measuring amniotic fluid lactate at point of care. BMC Res Notes 2013; 6:112. [PMID: 23531401 PMCID: PMC3618323 DOI: 10.1186/1756-0500-6-112] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2012] [Accepted: 03/18/2013] [Indexed: 11/10/2022] Open
Abstract
Background The level of lactate in amniotic fluid may provide useful clinical information when assessing progress of a woman’s labour and if so, a rapid, reliable method to assess amniotic fluid lactate is required in order to be clinically relevant. However, measuring lactate levels in amniotic fluid, using portable, handheld lactate meters may be less accurate than reference laboratory instruments designed to measure lactate levels in aqueous solutions. Prior to conducting a large study, we assessed recruitment, consent and sampling procedures, and the accuracy of a handheld lactate meter to measure lactate in amniotic fluid. We compared amniotic fluid lactate results obtained using the hand held Lactate Pro (Arkray) to results obtained using reference laboratory methods ABX Pentra 400 (Horiba). Results We recruited 35 nulliparous women during their antenatal hospital visits and tested amniotic fluid samples collected from 20 labouring women. The handheld Lactate Pro meter was found accurate from 9–20 mmol/L with a Passing & Bablok regression of y = 0.18 + 0.97x (95% CI 0.76–1.45). Amniotic fluid lactate results remained reliable in the presence of potential contaminants commonly encountered during labour; obstetric lubricant, blood and meconium. Conclusion The measurement of amniotic fluid lactate using the Lactate Pro meter was reliable compared to reference laboratory methods for measuring lactate levels in amniotic fluid. The pilot study enabled the refinement of information, recruitment, consenting and sampling procedures prior to commencing a large cohort study.
Collapse
Affiliation(s)
- Beverley Hall
- University of Sydney, Darlington, NSW 2006, Australia.
| | | | | | | | | | | |
Collapse
|
65
|
Kaplan-Sturk R, Åkerud H, Volgsten H, Hellström-Westas L, Wiberg-Itzel E. Outcome of deliveries in healthy but obese women: obesity and delivery outcome. BMC Res Notes 2013; 6:50. [PMID: 23388378 PMCID: PMC3573993 DOI: 10.1186/1756-0500-6-50] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2012] [Accepted: 01/22/2013] [Indexed: 11/29/2022] Open
Abstract
Background Obesity among fertile women is a global problem. 25% of pregnant Swedish women are overweight at admission to the antenatal clinic and 12% of them are considered as obese. Previous studies have shown an increased risk of delivery complications with an elevated maternal BMI. The aim of this study was to evaluate delivery outcomes in relation to maternal BMI on admission to the antenatal clinic. A healthy group of 787 women with full-term pregnancies and spontaneous onset of labor were included in the study. Delivery outcome was assessed in relation to maternal BMI when attending the antenatal clinic. Results The results indicated that in deliveries where the maternal BMI was >30 a high frequency of abnormal CTG trace during the last 30 minutes of labor was shown. A blood sample for evaluation of risk of fetal hypoxia was performed in only eight percent of these deliveries. A spontaneous vaginal delivery without intervention was noted in 85.7%, and 12% of neonates were delivered with an adverse fetal outcome compared to 2.8% in the group with a maternal BMI<30 (p<0.001). Conclusion These results indicate an increased risk at delivery for healthy, but obese women in labor. Furthermore, the delivery management may not always be optimal in these deliveries.
Collapse
Affiliation(s)
- Rebecka Kaplan-Sturk
- Department of Clinical Science and Education, Section of Obstetrics and Gynecology, Karolinska Institute, Soder Hospital, Stockholm 118 83, Sweden
| | | | | | | | | |
Collapse
|
66
|
O'Brien YM, Murphy DJ. The reliability of foetal blood sampling as a test of foetal acidosis in labour. Eur J Obstet Gynecol Reprod Biol 2012; 167:142-5. [PMID: 23270744 DOI: 10.1016/j.ejogrb.2012.11.016] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2012] [Revised: 11/09/2012] [Accepted: 11/28/2012] [Indexed: 12/17/2022]
Abstract
OBJECTIVES To establish whether foetal blood sampling for pH is a reliable test of foetal acidosis in labour by comparing paired foetal blood samples taken at a single procedure. STUDY DESIGN We conducted a prospective study assessing 293 consecutive attempts at foetal blood sampling in labour over a four month period from February to May 2012. A total of 100 paired samples were suitable for analysis. We compared the consistency of pH results of paired foetal blood samples, evaluated cases where inconsistent results would result in conflicting clinical decisions, and explored factors associated with discordant results. RESULTS There was a statistically significant difference between the mean pH of the two samples: 7.297 (SD 0.065) versus 7.315 (SD 0.059), p<0.0005. Of the 100 paired samples, 43 had a difference greater than the laboratory acceptable maximum analytical difference of 0.038. There was discordance between the samples in 16 cases with results crossing a decision threshold, and in 11 cases (69%) delivery was by emergency caesarean section. Inconsistent results were not associated with specific clinical factors and occurred more often with senior operators. CONCLUSION Foetal blood sampling is considered by many as the gold standard in assessing intrapartum foetal wellbeing. We have demonstrated inconsistency of paired foetal blood pH results which suggests that foetal blood sampling should not be considered infallible.
Collapse
Affiliation(s)
- Yvonne M O'Brien
- Academic Department of Obstetrics and Gynaecology, Coombe Women & Infants University Hospital & Trinity College, University of Dublin, Dublin 8, Ireland
| | | |
Collapse
|
67
|
YLI BRANKAM, KESSLER JØRG, EIKELAND TORUNN, HUSTAD BERITLUNDEN, DRAGNES WINNIE, HENRIKSEN TORE. What is the gold standard for intrapartum fetal monitoring? Acta Obstet Gynecol Scand 2012; 91:1011-4. [DOI: 10.1111/j.1600-0412.2012.01475.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
68
|
Holzmann M, Cnattingius S, Nordström L. Lactate production as a response to intrapartum hypoxia in the growth-restricted fetus. BJOG 2012; 119:1265-9. [PMID: 22804901 DOI: 10.1111/j.1471-0528.2012.03432.x] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
OBJECTIVE To analyse whether the increase in lactate in response to intrapartum hypoxia differs between small- (SGA), appropriate- (AGA) and large-for-gestational-age (LGA) fetuses. DESIGN Observational cohort study. SETTING Ten obstetric units in Sweden. POPULATION A cohort of 1496 women. METHODS A secondary analysis of a randomised controlled trial, in which 1496 women with fetal heart rate abnormalities, indicating fetal scalp blood sampling, were randomised to lactate analyses. After delivery, the neonates were divided according to birthweight for gestational age into SGA, AGA and LGA groups. MAIN OUTCOME MEASURE Lactate concentration in fetal scalp blood. SECONDARY OUTCOME MEASURES Acid-base balance in cord artery blood and Apgar score <7 at 5 minutes. RESULTS Median lactate concentrations in the SGA, AGA and LGA groups were 3.8, 3.0 and 2.2 mmol/l, respectively (SGA versus AGA, P = 0.017; LGA versus AGA, P = 0.009). In the subgroups with scalp lactate >4.8 mmol/l (lactacidaemia), the corresponding median (range) values were 6.2 (4.9-14.6), 5.9 (4.9-15.9) and 5.7 mmol/l (5.0-7.9 mmol/l), respectively (no significant differences between the groups). The proportions of neonates with cord artery pH < 7.00, metabolic acidaemia or Apgar score <7 at 5 minutes were similar in all weight groups. CONCLUSION SGA fetuses with fetal heart rate abnormalities have the same ability to produce lactate as a response to intrapartum hypoxia as AGA and LGA fetuses. The risk of a poor outcome associated with high lactate concentration is the same in SGA, AGA and LGA fetuses. Scalp blood lactate analysis is therefore a reliable method for intrapartum fetal surveillance of suspected growth-restricted fetuses scheduled for vaginal delivery at ≥ 34 weeks of gestation.
Collapse
Affiliation(s)
- M Holzmann
- Department of Women's and Children's Health, Karolinska Institutet, Karolinska University Hospital, Stockholm, Sweden.
| | | | | |
Collapse
|
69
|
Paris A, Maurice-Tison S, Coatleven F, Vandenbossche F, Dallay D, Horovitz J. Place du microdosage des lactates au scalp et au cordon devant des anomalies du rythme cardiaque fœtal pendant le travail. Étude prospective sur 162 patientes. ACTA ACUST UNITED AC 2012; 41:324-32. [DOI: 10.1016/j.jgyn.2011.11.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2011] [Revised: 10/23/2011] [Accepted: 11/02/2011] [Indexed: 11/25/2022]
|
70
|
Nordström L, Holzmann M. The value of fetal scalp blood lactate and/or pH analyses can only be evaluated in relation to neonatal outcome and not to frequency of interventions. Acta Obstet Gynecol Scand 2011; 91:879-80. [PMID: 22168907 DOI: 10.1111/j.1600-0412.2011.01342.x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
71
|
Berglund S. "Every case of asphyxia can be used as a learning example". Conclusions from an analysis of substandard obstetrical care. J Perinat Med 2011; 40:9-18. [PMID: 22080723 DOI: 10.1515/jpm.2011.108] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/20/2011] [Accepted: 08/17/2011] [Indexed: 11/15/2022]
Abstract
AIM To propose suggestions for improvements in care based on conclusions from studies on low Apgar scores and substandard care during labor. SETTING AND PATIENTS Studies on infants with low Apgar scores in a general obstetric population 2004-2006 and claims for financial compensation on the behalf of infants, based on the suspicion that substandard care in conjunction with childbirth has caused severe asphyxia or neonatal death in Sweden 1990-2005. RESULTS The most common flaws were related to insufficient fetal surveillance, defective interpretation of cardiotocography (CTG) tracings, not acting in a timely fashion on abnormal CTG, and the incautious use of oxytocin. Besides, in half of the infants a suboptimal mode of delivery added further trauma to the already asphyxiated infant. Additionally, resuscitation was unsatisfactory in many of these infants. The most critical flaw was defective compliance with the guidelines concerning ventilation and the early paging of skilled personnel in cases of imminent asphyxia or known complications during labor. In many case reports, the documentation of the neonatal resuscitation was insufficient to enable accurate and reliable evaluation. CONCLUSIONS Examples of proposed improvements in care during labor are the introduction of a permanent educational atmosphere with aside time for daily educational rounds and discussion, cooperation around the use of standardized terminology in CTG interpretation, the cautious use of oxytocin, and the routine paging of a pediatrician before birth in cases of complicated delivery or imminent asphyxia. The proposed interventions need to be evaluated in clinical trials in the future.
Collapse
Affiliation(s)
- Sophie Berglund
- Department of Clinical Sciences, Karolinska Institutet, Danderyd Hospital, Stockholm, Sweden.
| |
Collapse
|
72
|
Holzmann M, Cnattingius S, Nordstrom L. Outcome of severe intrapartum acidemia diagnosed with fetal scalp blood sampling. J Perinat Med 2011; 39:545-8. [PMID: 21787260 DOI: 10.1515/jpm.2011.062] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
AIM To analyze short-term neonatal outcome and the sampling to delivery interval in cases with severe intrapartum acidemia diagnosed with fetal scalp blood sampling (FBS). METHODS This is a secondary analysis of data from a trial of 2992 women, who were, when indicated, randomized to either lactate or pH analyses by FBS. Median and 95(th) centile values for lactate analyses were 2.9 mmol/L and 6.6 mmol/L, respectively. Corresponding pH values were 7.30 and 7.17. We defined severe intrapartum acidemia as lactate >6.6 mmol/L or pH <7.17. Outcome measures were cord artery pH <7.00, Apgar <7 at 5 min, hypoxic ischemic encephalopathy and time interval from FBS to delivery. RESULTS Severe intrapartum acidemia was present in 85/1355 (6.3%) cases with lactate analyses and in 69/1008 (6.8%) cases with pH analyses. Cord artery pH <7.00 occurred in 12/154 (7.8%), Apgar <7 at 5 min in 16/154 (10.4%) and hypoxic ischemic encephalopathy in 4/154 (2.6%) of the cases. There were no differences in outcomes between the two groups. However, delivery was expedited more rapidly in the pH management group (median 16 vs. 21 min; P=0.01). CONCLUSION Severe neonatal morbidity occurred in 10% or less in this high-risk group. FBS is an early marker of intrapartum hypoxia and can be used to prevent severe birth acidemia. Lactate might be an earlier marker than pH in the hypoxic process.
Collapse
Affiliation(s)
- Malin Holzmann
- Department of Obstetrics and Gynecology, Karolinska University Hospital, Karolinska Institute, Stockholm, Sweden.
| | | | | |
Collapse
|
73
|
HEINIS AYESHAM, SPAANDERMAN MARCE, GUNNEWIEK JACQUELINEMKLEIN, LOTGERING FREDK. Scalp blood lactate for intra-partum assessment of fetal metabolic acidosis. Acta Obstet Gynecol Scand 2011; 90:1107-14. [DOI: 10.1111/j.1600-0412.2011.01237.x] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
74
|
LILJESTRÖM LENA, WIKSTRÖM ANNAKARIN, HANSON ULF, ÅKERUD HELENA, JONSSON MARIA. Evaluation of the discrepancy between pH and lactate
in combined fetal scalp blood sampling. Acta Obstet Gynecol Scand 2011; 90:1088-93. [DOI: 10.1111/j.1600-0412.2011.01228.x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
75
|
Association Between Adverse Neonatal Outcome and Lactate Concentration in Amniotic Fluid. Obstet Gynecol 2011; 118:135-142. [DOI: 10.1097/aog.0b013e318220c0d4] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
76
|
Nordström L. Fetal scalp blood measurements during labour—lactate or pH? Clin Biochem 2011; 44:456-457. [DOI: 10.1016/j.clinbiochem.2011.03.007] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/01/2011] [Indexed: 10/18/2022]
|
77
|
Heazell AEP, Riches J, Hopkins L, Myers JE. Fetal blood sampling in early labour: is there an increased risk of operative delivery and fetal morbidity? BJOG 2011; 118:849-55. [DOI: 10.1111/j.1471-0528.2011.02922.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
78
|
|
79
|
Boog G. [Cerebral palsy and perinatal asphyxia (II--Medicolegal implications and prevention)]. ACTA ACUST UNITED AC 2011; 39:146-73. [PMID: 21354846 DOI: 10.1016/j.gyobfe.2011.01.015] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2011] [Accepted: 01/18/2011] [Indexed: 01/18/2023]
Abstract
Obstetric litigation is a growing problem in developed countries and its escalating cost together with increasing medical insurance premiums is a major concern for maternity service providers, leading to obstetric practice cessation by many practitioners. Fifty-four to 74 % of claims are based on cardiotocographic (CTG) abnormalities and their interpretation followed by inappropriate or delayed reactions. A critical analysis is performed about the nine criteria identified by the American College of Obstetricians and Gynecologists and the American Academy of Pediatrics in their task force on Neonatal Encephalopathy and Cerebral Palsy: four essential criteria defining neonatal asphyxia and five other suggesting an acute intrapartum event sufficient to cause cerebral palsy in term newborns. The importance of placental histologic examination is emphasized in order to confirm sudden catastrophic events occurring before or during labor or to detect occult thrombotic processes affecting the fetal circulation, patterns of decreased placenta reserve and adaptative responses to chronic hypoxia. It may also exclude intrapartum hypoxia by revealing some histologic patterns typical of acute chorioamnionitis and fetal inflammatory response or compatible with metabolic diseases. Magnetic resonance imaging (MRI) of the infant's damaged brain is very contributive to elucidate the mechanism and timing of asphyxia in conjunction with the clinical picture, by locating cerebral injuries predominantly in white or grey matter. Intrapartum asphyxia is sometimes preventable by delivering weak fetuses by cesarean sections before birth, by avoiding some "sentinel" events, and essentially by responding appropriately to CTG anomalies and performing an efficient neonatal resuscitation. During litigation procedures, it is necessary to have access to a readable CTG, a well-documented partogram, a complete analysis of umbilical cord gases, a placental pathology and an extensive clinical work-up of the newborn infant including cerebral MRI. Malpractice litigation in obstetric care can be reduced by permanent CTG education, respect of national CTG guidelines, use of adjuncts such as fetal blood sampling for pH or lactates, regular review of adverse events in Clinical Risk Management (CRM) groups and periodic audits about low arterial cord pH in newborns, admission to neonatal unit, the need for assisted ventilation and the decision-to-delivery interval for emergency operative deliveries. Considering the fast occurrence of fetal cerebral hypoxic injuries, and thus despite an adequate management, many intrapartum asphyxias will not be preventable. Conversely, well-documented hypoxic-ischemic brain insults during the antenatal period do not automatically exclude intrapartum suboptimal obstetric care.
Collapse
Affiliation(s)
- G Boog
- Service de gynécologie-obstétrique, hôpital Mère-et-Enfant, CHU de Nantes, 38 boulevard Jean-Monnet, Nantes cedex 1, France.
| |
Collapse
|
80
|
Groppetti D, Pecile A, Del Carro AP, Copley K, Minero M, Cremonesi F. Evaluation of newborn canine viability by means of umbilical vein lactate measurement, apgar score and uterine tocodynamometry. Theriogenology 2010; 74:1187-96. [PMID: 20615542 DOI: 10.1016/j.theriogenology.2010.05.020] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2010] [Revised: 04/26/2010] [Accepted: 05/13/2010] [Indexed: 10/19/2022]
Abstract
Newborn viability evaluation and early detection of fetal distress could contribute to reducing mortality at birth in canine species. High neonatal mortality rate in dogs is reported subsequent to complicated or uncomplicated whelping. Umbilical vein lactate and tocodynamometry could provide valuable clinical information to the obstetricians so that appropriate medical and surgical treatments or oxygen and warm administration can be properly and timely applied to mother and newborn pup. In humans, the fetal lactate level represents an objective indicator of fetal distress and a valid predictor of babies' survival. Fetal acidosis recognition by umbilical lactate (UL) measurement, APGAR score classification, and uterine activity monitoring during labour, can represent an advanced system in the evaluation of the canine newborn patient. The purpose of this study was to correlate UL levels with canine neonatal morbidity and mortality within 48 h of birth. We evaluated the relationship among neonatal parameters at birth (mucous membrane color, heart and respiratory rate, reflex irritability, mobility, suckling and vocalization, UL, weight, and temperature) with labour characteristics (uterine contractions recorded by the tocodynamometric system of Whelpwise ™ Veterinary Perinatal Specialties ®, delivery time, and pup presentation), in view to predict pup viability. We considered also vaginal parturition versus elective and emergency Caesarean section, and uterotonic drugs influence on delivery. Umbilical lactate concentration proved to be useful to predict canine neonatal mortality within 48 h of birth (P < 0.05). We identified 5 mmol/L of vein umbilical lactate concentration as the cut off value, allowing us to distinguish between healthy and distressed pups. Higher values of UL were related with distressed pups, whereas lower values characterized vigorous pups. Lactate concentrations lower than 5 mmol/L and APGAR scores higher than 9, related to mean delivery time of 105 min with effective uterine contractions (10 mm of Hg of strength or more, frequency from 4 to 12 contractions per hour, and 2-5 min in duration), should be considered good prognostic factors in canine labour and neonatology.
Collapse
Affiliation(s)
- D Groppetti
- Department of Veterinary Clinical Science, Reproduction Unit, Università degli Studi di Milano, Via Celoria 10, 20133 Milano, Italy.
| | | | | | | | | | | |
Collapse
|
81
|
East CE, Leader LR, Sheehan P, Henshall NE, Colditz PB. Intrapartum fetal scalp lactate sampling for fetal assessment in the presence of a non-reassuring fetal heart rate trace. Cochrane Database Syst Rev 2010:CD006174. [PMID: 20238343 DOI: 10.1002/14651858.cd006174.pub2] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
BACKGROUND Fetal blood sampling for lactate estimation may be considered following identification of an abnormal or non-reassuring fetal heart rate pattern. The smaller volume of blood required for this test, compared with the more traditional pH estimation, may improve sampling rates. The appropriate use of this practice mandates systematic review of its safety and clinical effectiveness prior to widespread introduction. OBJECTIVES To evaluate the effectiveness and risks of fetal scalp lactate sampling in the assessment of fetal well-being during labour, compared with no testing or alternative testing. SEARCH STRATEGY We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (November 2009). SELECTION CRITERIA All published and unpublished randomised and quasi-randomised trials that compared fetal scalp lactate testing with no testing or alternative testing to evaluate fetal status in the presence of a non-reassuring cardiotocograph during labour. DATA COLLECTION AND ANALYSIS Two review authors assessed the studies independently. MAIN RESULTS The two identified randomised trials considered outcomes for 3348 mother-baby pairs allocated to either lactate or pH estimation of fetal blood samples in labour. There were no statistically significant differences for any fetal/neonatal/infant outcomes, including low Apgar score at five minutes, admission to neonatal intensive care units or neonatal encephalopathy, or for low umbilical arterial pH, base deficit or metabolic acidaemia. There was a statistically higher success rate for lactate compared with pH estimation (risk ratio 1.10, 95% confidence interval 1.08 to 1.12, n = 2992). There were no significant between-group differences in mode of birth or operative birth for non-reassuring fetal status. No studies reported outcomes of maternal satisfaction with fetal monitoring, anxiety, length of hospital stay or economic analysis. AUTHORS' CONCLUSIONS When further testing to assess fetal well-being in labour is indicated, fetal scalp blood lactate estimation is more likely to be successfully undertaken than pH estimation. Action cut-off lactate values need to consider the lactate meter used. Further studies may consider sub-group analysis by gestational age, the stage of labour and sampling within a prolonged second stage of labour. Additionally, future studies may address longer-term neonatal outcomes, maternal satisfaction with intrapartum fetal monitoring and an economic analysis.
Collapse
Affiliation(s)
- Christine E East
- Department of Obstetrics and Gynaecology, University of Melbourne, Pregnancy Research Centre, Department of Perinatal Medicine, Royal Women's Hospital, 20 Flemington Road, Parkville, Victoria, Australia, 3052
| | | | | | | | | |
Collapse
|
82
|
Raičević S, Čubrilo D, Arsenijević S, Vukčevic G, Živković V, Vuletić M, Barudžić N, Andjelković N, Antonović O, Jakovljević V. Oxidative stress in fetal distress: potential prospects for diagnosis. OXIDATIVE MEDICINE AND CELLULAR LONGEVITY 2010. [PMID: 20716946 PMCID: PMC2952080 DOI: 10.4161/oxim.3.3.7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Our aim was to investigate the relation between fetal distress and oxidative stress. Fetal distress was associated with increased concentration of superoxide in the fetal blood and with significant increase of the level of H2O2 in both maternal and fetal blood. The activity of superoxide dismutase was increased roughly sixfold (p<0.01) in the maternal (7330 +/- 2240 U/g of hemoglobin in controls (C) and 36811 +/- 16862 U/g in fetal distress (FD)) and fetal blood (C: 5930 +/- 2641 U/g; FD: 41912 +/- 17133 U/g). In contrast, fetal distress was related to a considerable decrease of catalase activity in both maternal (C: 26011 +/- 8811 U/g; FD: 7212 +/- 1270 U/g) and fetal blood (C: 37194 +/- 9191 U/g; FD: 6173 +/- 1965 U/g). From this we concluded that in fetal distress, the maternal and fetal bloods are exposed to superoxide- and H2O2-mediated oxidative stress, which could be initiated by hypoxic conditions in the fetal blood and placenta. A tremendous increase/decrease of the activities of superoxide dismutase/catalase in the blood of women bearing a distressed fetus in comparison to healthy subjects implies that the assessment of superoxide dismutase/catalase activity could be of use for establishing a timely and accurate ante- or intrapartum diagnosis of fetal distress.
Collapse
Affiliation(s)
- Saša Raičević
- Clinic of Gynecology and Obstetrics; Clinical Centre of Montenegro; Podgorica, Montenegro
| | - Dejan Čubrilo
- Department of Physiology; Faculty of Medicine; University of Kragujevac; Kragujevac, Serbia
| | | | - Gordana Vukčevic
- Clinic of Gynecology and Obstetrics; Clinical Centre of Montenegro; Podgorica, Montenegro
| | - Vladimir Živković
- Department of Physiology; Faculty of Medicine; University of Kragujevac; Kragujevac, Serbia
| | - Milena Vuletić
- Department of Physiology; Faculty of Medicine; University of Kragujevac; Kragujevac, Serbia
| | - Nevena Barudžić
- Department of Physiology; Faculty of Medicine; University of Kragujevac; Kragujevac, Serbia
| | - Nebojša Andjelković
- Department of Haematology Internal Clinic; Clinical Centre ”Kragujevac“; Faculty of Medicine; University of Kragujevac; Kragujevac, Serbia
| | - Olga Antonović
- Department of Neonatology; Institute for Gynecology and Obstetrics; Clinical Centre of Serbia; Belgrade, Serbia
| | - Vladimir Jakovljević
- Department of Physiology; Faculty of Medicine; University of Kragujevac; Kragujevac, Serbia
| |
Collapse
|
83
|
Holzmann M, Cnattingius S, Nordstrom L. 658: Outcome in cases with severe intrapartum acidemia diagnosed with fetal scalp blood sampling. Am J Obstet Gynecol 2009. [DOI: 10.1016/j.ajog.2009.10.523] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
84
|
Torrance HL, Benders MJ, Derks JB, Rademaker CMA, Bos AF, Van Den Berg P, Longini M, Buonocore G, Venegas M, Baquero H, Visser GHA, Van Bel F. Maternal allopurinol during fetal hypoxia lowers cord blood levels of the brain injury marker S-100B. Pediatrics 2009; 124:350-7. [PMID: 19564319 DOI: 10.1542/peds.2008-2228] [Citation(s) in RCA: 62] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
BACKGROUND Fetal hypoxia is an important determinant of neonatal encephalopathy caused by birth asphyxia, in which hypoxia-induced free radical formation plays an important role. HYPOTHESIS Maternal treatment with allopurinol, will cross the placenta during fetal hypoxia (primary outcome) and reduce S-100B and free radical formation (secondary outcome). METHODS In a randomized, double-blind feasibility study, 53 pregnant women in labor (54 fetuses) with a gestational age of >36 weeks and fetal hypoxia, as indicated by abnormal/nonreassuring fetal heart rate tracing or fetal scalp pH of <7.20, received 500 mg of allopurinol or placebo intravenously. Severity of fetal hypoxia, brain damage and free radical formation were assessed by arterial cord blood lactate, S-100B and non-protein-bound-iron concentrations, respectively. At birth, maternal and cord blood concentrations of allopurinol and its active metabolite oxypurinol were determined. RESULTS Allopurinol and oxypurinol concentrations were within the therapeutic range in the mother (allopurinol > 2 mg/L and/or oxypurinol > 4 mg/L) but not always in arterial cord blood. We therefore created 3 groups: a placebo (n = 27), therapeutic allopurinol (n = 15), and subtherapeutic allopurinol group (n = 12). Cord lactate concentration did not differ, but S-100B was significantly lower in the therapeutic allopurinol group compared with the placebo and subtherapeutic allopurinol groups (P < .01). Fewer therapeutic allopurinol cord samples had measurable non-protein-bound iron concentrations compared with placebo (P < .01). CONCLUSIONS Maternal allopurinol/oxypurinol crosses the placenta during fetal hypoxia. In fetuses/newborns with therapeutic allopurinol/oxypurinol concentrations in cord blood, lower plasma levels of the brain injury marker protein S-100B were detected. A larger allopurinol trial in compromised fetuses at term seems warranted. The allopurinol dosage must be adjusted to achieve therapeutic fetal allopurinol/oxypurinol concentrations.
Collapse
Affiliation(s)
- Helen L Torrance
- Perinatal Center, University Medical Center/Wilhelmina Children's Hospital, Utrecht, Netherlands;.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
85
|
Abstract
Lactate measurement has benefits over pH estimation
Collapse
|
86
|
Kent A. Monitoring during labor. REVIEWS IN OBSTETRICS & GYNECOLOGY 2008; 1:144-146. [PMID: 19015766 PMCID: PMC2582638] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Affiliation(s)
- Athol Kent
- Department of Obstetrics & Gynaecology, University of Cape Town Rondebosch, South Africa
| |
Collapse
|