51
|
Kang J, Feng P, Wei X, Lam EY, Tsia KK, Wong KKY. 102-nm, 44.5-MHz inertial-free swept source by mode-locked fiber laser and time stretch technique for optical coherence tomography. OPTICS EXPRESS 2018; 26:4370-4381. [PMID: 29475287 DOI: 10.1364/oe.26.004370] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
A swept source with both high repetition-rate and broad bandwidth is indispensable to enable optical coherence tomography (OCT) with high imaging rate and high axial resolution. However, available swept sources are commonly either limited in speed (sub-MHz) by inertial or kinetic component, or limited in bandwidth (<100 nm) by the gain medium. Here we report an ultrafast broadband (over 100 nm centered at 1.55-µm) all-fiber inertial-free swept source built upon a high-power dispersion-managed fiber laser in conjunction with an optical time-stretch module which bypasses complex optical amplification scheme, which result in a portable and compact implementation of time-stretch OCT (TS-OCT) at A-scan rate of 44.5-MHz, axial resolution of 14 µm in air (or 10 µm in tissue), and flat sensitivity roll-off within 4.3 mm imaging range. Together with the demonstration of two- and three-dimensional OCT imaging of a mud-fish eye anterior segment, we also perform comprehensive studies on the imaging depth, receiver bandwidth, and group velocity dispersion condition. This all-fiber inertia-free swept source could provide a promising source solution for SS-OCT system to realize high-performance volumetric OCT imaging in real time.
Collapse
|
52
|
Che D, Sun C, Shieh W. Direct detection of the optical field beyond single polarization mode. OPTICS EXPRESS 2018; 26:3368-3380. [PMID: 29401865 DOI: 10.1364/oe.26.003368] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2017] [Accepted: 01/19/2018] [Indexed: 06/07/2023]
Abstract
Direct detection is traditionally regarded as a detection method that recovers only the optical intensity. Compared with coherent detection, it owns a natural advantage-the simplicity-but lacks a crucial capability of field recovery that enables not only the multi-dimensional modulation, but also the digital compensation of the fiber impairments linear with the optical field. Full-field detection is crucial to increase the capacity-distance product of optical transmission systems. A variety of methods have been investigated to directly detect the optical field of the single polarization mode, which normally sends a carrier traveling with the signal for self-coherent detection. The crux, however, is that any optical transmission medium supports at least two propagating modes (e.g. single mode fiber supports two polarization modes), and until now there is no direct detection that can recover the complete set of optical fields beyond one polarization, due to the well-known carrier fading issue after mode demultiplexing induced by the random mode coupling. To avoid the fading, direct detection receivers should recover the signal in an intensity space isomorphic to the optical field without loss of any degrees of freedom, and a bridge should be built between the field and its isomorphic space for the multi-mode field recovery. Based on this thinking, we propose, for the first time, the direct detection of dual polarization modes by a novel receiver concept, the Stokes-space field receiver (SSFR) and its extension, the generalized SSFR for multiple spatial modes. The idea is verified by a dual-polarization field recovery of a polarization-multiplexed complex signal over an 80-km single mode fiber transmission. SSFR can be applied to a much wider range of fields beyond optical communications such as coherent sensing and imaging, where simple field recovery without an extra local laser is desired for enhanced system performance.
Collapse
|
53
|
DiLazaro T, Nehmetallah G. Large-volume, low-cost, high-precision FMCW tomography using stitched DFBs. OPTICS EXPRESS 2018; 26:2891-2904. [PMID: 29401823 DOI: 10.1364/oe.26.002891] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/16/2017] [Accepted: 01/24/2018] [Indexed: 06/07/2023]
Abstract
Optical frequency-modulated continuous-wave (FMCW) reflectometry is a ranging technique that allows for high-resolution distance measurements over long ranges. Similarly, swept-source optical coherence tomography (SS-OCT) provides high-resolution depth imaging over typically shorter distances and higher scan speeds. In this work, we demonstrate a low-cost, low-bandwidth 3D imaging system that provides the high axial resolution imaging capability normally associated with SS-OCT over typical FMCW ranging depths. The imaging system combines 12 distributed feedback laser (DFB) elements from a single butterfly module to provide an axial resolution of 27.1 μm over 6 m of depth and up to 14 cubic meters of volume. Active sweep linearization is used, greatly reducing the signal processing overhead. Various sub-surface, OCT-style tomograms of semi-transparent objects are shown, as well as 3D maps of various objects over depths ranging from sub-millimeter to several meters. Such imaging capability would make long-distance, high-resolution surface interrogation possible in a low-cost, compact package.
Collapse
|
54
|
Siddiqui M, Nam AS, Tozburun S, Lippok N, Blatter C, Vakoc BJ. High-speed optical coherence tomography by circular interferometric ranging. NATURE PHOTONICS 2018; 12:111-116. [PMID: 29657576 PMCID: PMC5894866 DOI: 10.1038/s41566-017-0088-x] [Citation(s) in RCA: 50] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2017] [Accepted: 12/18/2017] [Indexed: 05/17/2023]
Abstract
Existing three-dimensional optical imaging methods excel in controlled environments but are difficult to deploy over large, irregular and dynamic fields. This has limited imaging in areas such as material inspection and medicine. To better address these applications, we developed methods in optical coherence tomography (OCT) to efficiently interrogate sparse scattering fields, i.e., those in which most locations (voxels) do not generate meaningful signal. Frequency comb sources are used to superimpose reflected signals from equispaced locations through optical subsampling. This results in circular ranging, and reduces the number of measurements required to interrogate large volumetric fields. As a result, signal acquisition barriers that have limited speed and field in OCT are avoided. With a new ultrafast, time-stretched frequency comb laser design operating with 7.6 MHz to 18.9 MHz repetition rates, we achieved imaging of multi-cm3 fields at up to 7.5 volumes per second.
Collapse
Affiliation(s)
- Meena Siddiqui
- Harvard Medical School, Boston, Massachusetts 02115, USA
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts 02114, USA
- Harvard-MIT Health Sciences & Technology (HST), Cambridge, Massachusetts 02139, USA
| | - Ahhyun S. Nam
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts 02114, USA
- Department of Mechanical Engineering, Massachusetts Institute of Technology (MIT), Cambridge, Massachusetts 02139, USA
| | - Serhat Tozburun
- Harvard Medical School, Boston, Massachusetts 02115, USA
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts 02114, USA
| | - Norman Lippok
- Harvard Medical School, Boston, Massachusetts 02115, USA
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts 02114, USA
| | - Cedric Blatter
- Harvard Medical School, Boston, Massachusetts 02115, USA
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts 02114, USA
| | - Benjamin J. Vakoc
- Harvard Medical School, Boston, Massachusetts 02115, USA
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts 02114, USA
- Harvard-MIT Health Sciences & Technology (HST), Cambridge, Massachusetts 02139, USA
- Correspondence to: Benjamin J. Vakoc
| |
Collapse
|
55
|
Xu J, Song S, Men S, Wang RK. Long ranging swept-source optical coherence tomography-based angiography outperforms its spectral-domain counterpart in imaging human skin microcirculations. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:1-11. [PMID: 29185292 PMCID: PMC5712670 DOI: 10.1117/1.jbo.22.11.116007] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/14/2017] [Accepted: 11/08/2017] [Indexed: 05/07/2023]
Abstract
There is an increasing demand for imaging tools in clinical dermatology that can perform in vivo wide-field morphological and functional examination from surface to deep tissue regions at various skin sites of the human body. The conventional spectral-domain optical coherence tomography-based angiography (SD-OCTA) system is difficult to meet these requirements due to its fundamental limitations of the sensitivity roll-off, imaging range as well as imaging speed. To mitigate these issues, we demonstrate a swept-source OCTA (SS-OCTA) system by employing a swept source based on a vertical cavity surface-emitting laser. A series of comparisons between SS-OCTA and SD-OCTA are conducted. Benefiting from the high system sensitivity, long imaging range, and superior roll-off performance, the SS-OCTA system is demonstrated with better performance in imaging human skin than the SD-OCTA system. We show that the SS-OCTA permits remarkable deep visualization of both structure and vasculature (up to ∼2 mm penetration) with wide field of view capability (up to 18×18 mm2), enabling a more comprehensive assessment of the morphological features as well as functional blood vessel networks from the superficial epidermal to deep dermal layers. It is expected that the advantages of the SS-OCTA system will provide a ground for clinical translation, benefiting the existing dermatological practice.
Collapse
Affiliation(s)
- Jingjiang Xu
- University of Washington, Department of Bioengineering, Seattle, Washington, United States
| | - Shaozhen Song
- University of Washington, Department of Bioengineering, Seattle, Washington, United States
| | - Shaojie Men
- University of Washington, Department of Bioengineering, Seattle, Washington, United States
| | | |
Collapse
|
56
|
Song S, Xu J, Men S, Shen TT, Wang RK. Robust numerical phase stabilization for long-range swept-source optical coherence tomography. JOURNAL OF BIOPHOTONICS 2017; 10:1398-1410. [PMID: 28485132 PMCID: PMC5831409 DOI: 10.1002/jbio.201700034] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/08/2017] [Revised: 03/28/2017] [Accepted: 04/03/2017] [Indexed: 05/03/2023]
Abstract
A novel phase stabilization technique is demonstrated with significant improvement in the phase stability of a micro-electromechanical (MEMS) vertical cavity surface-emitting laser (VCSEL) based swept-source optical coherence tomography (SS-OCT) system. Without any requirements of hardware modifications, the new fully numerical phase stabilization technique features high tolerance to acquisition jitter, and significantly reduced budget in computational effort. We demonstrate that when measured with biological tissue, this technique enables a phase sensitivity of 89 mrad in highly scattering tissue, with image ranging distance of up to 12.5 mm at A-line scan rate of 100.3 kHz. We further compare the performances delivered by the phase-stabilization approach with conventional numerical approach for accuracy and computational efficiency. Imaging result of complex signal-based optical coherence tomography angiography (OCTA) and Doppler OCTA indicate that the proposed phase stabilization technique is robust, and efficient in improving the image contrast-to-noise ratio and extending OCTA depth range. The proposed technique can be universally applied to improve phase-stability in generic SS-OCT with different scale of scan rates without a need for special treatment.
Collapse
Affiliation(s)
- Shaozhen Song
- University of Washington, Department of Bioengineering, Seattle, WA 98195, USA
| | - Jingjiang Xu
- University of Washington, Department of Bioengineering, Seattle, WA 98195, USA
| | - Shaojie Men
- University of Washington, Department of Bioengineering, Seattle, WA 98195, USA
| | - Tueng T Shen
- University of Washington, Department of Bioengineering, Seattle, WA 98195, USA
- University of Washington, Department of Ophthalmology, Seattle, WA 98195, USA
| | - Ruikang K Wang
- University of Washington, Department of Bioengineering, Seattle, WA 98195, USA
- University of Washington, Department of Ophthalmology, Seattle, WA 98195, USA
| |
Collapse
|
57
|
Li F, Yablon J, Velten A, Gupta M, Cossairt O. High-depth-resolution range imaging with multiple-wavelength superheterodyne interferometry using 1550-nm lasers. APPLIED OPTICS 2017; 56:H51-H56. [PMID: 29091666 DOI: 10.1364/ao.56.000h51] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/01/2017] [Accepted: 08/22/2017] [Indexed: 06/07/2023]
Abstract
Lasers and laser diodes are widely used as illumination sources for optical imaging techniques. Time-of-flight (ToF) cameras with laser diodes and range imaging based on optical interferometry systems using lasers are among these techniques, with various applications in fields such as metrology and machine vision. ToF cameras can have imaging ranges of several meters, but offer only centimeter-level depth resolution. On the other hand, range imaging based on optical interferometry has depth resolution on the micrometer and even nanometer scale, but offers very limited (sub-millimeter) imaging ranges. In this paper, we propose a range imaging system based on multi-wavelength superheterodyne interferometry to simultaneously provide sub-millimeter depth resolution and an imaging range of tens to hundreds of millimeters. The proposed setup uses two tunable III-V semiconductor lasers and offers leverage between imaging range and resolution. The system is composed entirely of fiber connections except the scanning head, which enables it to be made into a portable device. We believe our proposed system has the potential to tremendously benefit many fields, such as metrology and computer vision.
Collapse
|
58
|
Qian R, Carrasco-Zevallos OM, Mangalesh S, Sarin N, Vajzovic L, Farsiu S, Izatt JA, Toth CA. Characterization of Long Working Distance Optical Coherence Tomography for Imaging of Pediatric Retinal Pathology. Transl Vis Sci Technol 2017; 6:12. [PMID: 29057163 PMCID: PMC5644711 DOI: 10.1167/tvst.6.5.12] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2017] [Accepted: 08/28/2017] [Indexed: 11/24/2022] Open
Abstract
PURPOSE We determined the feasibility of fovea and optic nerve head imaging with a long working distance (LWD) swept source optical coherence tomography (OCT) prototype in adults, teenagers, and young children. METHODS A prototype swept source OCT system with a LWD (defined as distance from the last optical element of the imaging system to the eye) of 350 mm with custom fixation targets was developed to facilitate imaging of children. Imaging was performed in 49 participants from three age groups: 26 adults, 16 children 13 to 18 years old (teenagers), and seven children under 6 years old (young children) under an approved institutional review board protocol. The imaging goal was to acquire high quality scans of the fovea and optic nerve in each eye in the shortest time possible. OCT B-scans and volumes of the fovea and optic nerve head of each eligible eye were captured and graded based on four categories (lateral and axial centration, contrast, and resolution) and on ability to determine presence or absence of pathology. RESULTS LWD-OCT imaging was successful in 88 of 94 eligible eyes, including seven of 10 eyes of young children. Of the successfully acquired OCT images, 83% of B-scan and volumetric images, including 86% from young children, were graded as high-quality scans. Pathology was observed in high-quality OCT images. CONCLUSIONS The prototype LWD-OCT system achieved high quality retinal imaging of adults, teenagers, and some young children with and without pathology with reasonable alignment time. TRANSLATIONAL RELEVANCE The LWD-OCT system can facilitate imaging in children.
Collapse
Affiliation(s)
- Ruobing Qian
- Department of Biomedical Engineering, Duke University, Durham, NC, USA
| | | | - Shwetha Mangalesh
- Department of Ophthalmology, Duke University Medical Center, Durham, NC, USA
| | - Neeru Sarin
- Department of Ophthalmology, Duke University Medical Center, Durham, NC, USA
| | - Lejla Vajzovic
- Department of Ophthalmology, Duke University Medical Center, Durham, NC, USA
| | - Sina Farsiu
- Department of Biomedical Engineering, Duke University, Durham, NC, USA.,Department of Ophthalmology, Duke University Medical Center, Durham, NC, USA
| | - Joseph A Izatt
- Department of Biomedical Engineering, Duke University, Durham, NC, USA.,Department of Ophthalmology, Duke University Medical Center, Durham, NC, USA
| | - Cynthia A Toth
- Department of Biomedical Engineering, Duke University, Durham, NC, USA.,Department of Ophthalmology, Duke University Medical Center, Durham, NC, USA
| |
Collapse
|
59
|
van Rooij J, Kalkman J. Sub-millimeter depth-resolved digital holography. APPLIED OPTICS 2017; 56:7286-7293. [PMID: 29047993 DOI: 10.1364/ao.56.007286] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2017] [Accepted: 08/15/2017] [Indexed: 06/07/2023]
Abstract
We present sub-millimeter full-field depth from focus digital holography of surface topography of rough objects. For each pixel, the depth of the object is calculated from the variance of the intensity image over a set of reconstruction distances. First, we theoretically describe the axial resolution of this method and show that sub-millimeter resolution is feasible. Second, using a digital holography setup without magnifying optics or lateral scanning we experimentally demonstrate 100 μm axial resolution depth ranging and surface topography imaging. This is significantly better than what has previously been reported using digital holography and could make this technique useful for rapid large-area characterization of surface topography of objects.
Collapse
|
60
|
Huang Y, Badar M, Nitkowski A, Weinroth A, Tansu N, Zhou C. Wide-field high-speed space-division multiplexing optical coherence tomography using an integrated photonic device. BIOMEDICAL OPTICS EXPRESS 2017; 8:3856-3867. [PMID: 28856055 PMCID: PMC5560846 DOI: 10.1364/boe.8.003856] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2017] [Revised: 07/21/2017] [Accepted: 07/23/2017] [Indexed: 05/15/2023]
Abstract
Space-division multiplexing optical coherence tomography (SDM-OCT) is a recently developed parallel OCT imaging method in order to achieve multi-fold speed improvement. However, the assembly of fiber optics components used in the first prototype system was labor-intensive and susceptible to errors. Here, we demonstrate a high-speed SDM-OCT system using an integrated photonic chip that can be reliably manufactured with high precisions and low per-unit cost. A three-layer cascade of 1 × 2 splitters was integrated in the photonic chip to split the incident light into 8 parallel imaging channels with ~3.7 mm optical delay in air between each channel. High-speed imaging (~1s/volume) of porcine eyes ex vivo and wide-field imaging (~18.0 × 14.3 mm2) of human fingers in vivo were demonstrated with the chip-based SDM-OCT system.
Collapse
Affiliation(s)
- Yongyang Huang
- Department of Electrical and Computer Engineering, Lehigh University, 27 Memorial Drive W, Bethlehem, PA 18015, USA
- Center for Photonics and Nanoelectronics, Lehigh University, 27 Memorial Drive W, Bethlehem, PA 18015, USA
| | - Mudabbir Badar
- Department of Electrical and Computer Engineering, Lehigh University, 27 Memorial Drive W, Bethlehem, PA 18015, USA
- Center for Photonics and Nanoelectronics, Lehigh University, 27 Memorial Drive W, Bethlehem, PA 18015, USA
| | - Arthur Nitkowski
- Tornado Spectral Systems, Inc., 555 Richmond Street West, Suite 402, Toronto, ON, M5V 3(B)1, Canada
| | - Aaron Weinroth
- Tornado Spectral Systems, Inc., 555 Richmond Street West, Suite 402, Toronto, ON, M5V 3(B)1, Canada
| | - Nelson Tansu
- Department of Electrical and Computer Engineering, Lehigh University, 27 Memorial Drive W, Bethlehem, PA 18015, USA
- Center for Photonics and Nanoelectronics, Lehigh University, 27 Memorial Drive W, Bethlehem, PA 18015, USA
| | - Chao Zhou
- Department of Electrical and Computer Engineering, Lehigh University, 27 Memorial Drive W, Bethlehem, PA 18015, USA
- Center for Photonics and Nanoelectronics, Lehigh University, 27 Memorial Drive W, Bethlehem, PA 18015, USA
- Department of Bioengineering, Lehigh University, Bethlehem, PA 18015, USA
| |
Collapse
|
61
|
de Boer JF, Leitgeb R, Wojtkowski M. Twenty-five years of optical coherence tomography: the paradigm shift in sensitivity and speed provided by Fourier domain OCT [Invited]. BIOMEDICAL OPTICS EXPRESS 2017; 8:3248-3280. [PMID: 28717565 PMCID: PMC5508826 DOI: 10.1364/boe.8.003248] [Citation(s) in RCA: 104] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/13/2017] [Revised: 04/26/2017] [Accepted: 05/22/2017] [Indexed: 05/19/2023]
Abstract
Optical coherence tomography (OCT) has become one of the most successful optical technologies implemented in medicine and clinical practice mostly due to the possibility of non-invasive and non-contact imaging by detecting back-scattered light. OCT has gone through a tremendous development over the past 25 years. From its initial inception in 1991 [Science254, 1178 (1991)] it has become an indispensable medical imaging technology in ophthalmology. Also in fields like cardiology and gastro-enterology the technology is envisioned to become a standard of care. A key contributor to the success of OCT has been the sensitivity and speed advantage offered by Fourier domain OCT. In this review paper the development of FD-OCT will be revisited, providing a single comprehensive framework to derive the sensitivity advantage of both SD- and SS-OCT. We point out the key aspects of the physics and the technology that has enabled a more than 2 orders of magnitude increase in sensitivity, and as a consequence an increase in the imaging speed without loss of image quality. This speed increase provided a paradigm shift from point sampling to comprehensive 3D in vivo imaging, whose clinical impact is still actively explored by a large number of researchers worldwide.
Collapse
Affiliation(s)
- Johannes F. de Boer
- Department of Physics and Astronomy and LaserLaB Amsterdam, VU University, De Boelelaan 1105, 1081 HV Amsterdam, Department of Ophthalmology, VU Medical Center, Amsterdam, The Netherlands
- Authors are listed in alphabetical order and contributed equally
| | - Rainer Leitgeb
- Christian Doppler Laboratory OPTRAMED, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria
- Authors are listed in alphabetical order and contributed equally
| | - Maciej Wojtkowski
- Physical Optics and Biophotonics Group, Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52 01-224 Warsaw, Poland
- Authors are listed in alphabetical order and contributed equally
| |
Collapse
|
62
|
Pircher M, Zawadzki RJ. Review of adaptive optics OCT (AO-OCT): principles and applications for retinal imaging [Invited]. BIOMEDICAL OPTICS EXPRESS 2017; 8:2536-2562. [PMID: 28663890 PMCID: PMC5480497 DOI: 10.1364/boe.8.002536] [Citation(s) in RCA: 121] [Impact Index Per Article: 15.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2017] [Revised: 04/08/2017] [Accepted: 04/09/2017] [Indexed: 05/17/2023]
Abstract
In vivo imaging of the human retina with a resolution that allows visualization of cellular structures has proven to be essential to broaden our knowledge about the physiology of this precious and very complex neural tissue that enables the first steps in vision. Many pathologic changes originate from functional and structural alterations on a cellular scale, long before any degradation in vision can be noted. Therefore, it is important to investigate these tissues with a sufficient level of detail in order to better understand associated disease development or the effects of therapeutic intervention. Optical retinal imaging modalities rely on the optical elements of the eye itself (mainly the cornea and lens) to produce retinal images and are therefore affected by the specific arrangement of these elements and possible imperfections in curvature. Thus, aberrations are introduced to the imaging light and image quality is degraded. To compensate for these aberrations, adaptive optics (AO), a technology initially developed in astronomy, has been utilized. However, the axial sectioning provided by retinal AO-based fundus cameras and scanning laser ophthalmoscope instruments is limited to tens of micrometers because of the rather small available numerical aperture of the eye. To overcome this limitation and thus achieve much higher axial sectioning in the order of 2-5µm, AO has been combined with optical coherence tomography (OCT) into AO-OCT. This enabled for the first time in vivo volumetric retinal imaging with high isotropic resolution. This article summarizes the technical aspects of AO-OCT and provides an overview on its various implementations and some of its clinical applications. In addition, latest developments in the field, such as computational AO-OCT and wavefront sensor less AO-OCT, are covered.
Collapse
Affiliation(s)
- Michael Pircher
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Währinger Gürtel 18-20/4L, 1090 Vienna, Austria
| | - Robert J Zawadzki
- UC Davis RISE Eye-Pod Laboratory, Dept. of Cell Biology and Human Anatomy, University of California Davis, 4320 Tupper Hall, Davis, CA 95616, USA
- Vision Science and Advanced Retinal Imaging Laboratory (VSRI) and Department of Ophthalmology and Vision Science, UC Davis, 4860 Y Street, Ste. 2400, Sacramento, CA 95817, USA
| |
Collapse
|
63
|
Spectral Domain Optical Coherence Tomography for Non-Destructive Testing of Protection Coatings on Metal Substrates. APPLIED SCIENCES-BASEL 2017. [DOI: 10.3390/app7040364] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
64
|
Klein T, Huber R. High-speed OCT light sources and systems [Invited]. BIOMEDICAL OPTICS EXPRESS 2017; 8:828-859. [PMID: 28270988 PMCID: PMC5330584 DOI: 10.1364/boe.8.000828] [Citation(s) in RCA: 111] [Impact Index Per Article: 13.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2016] [Revised: 01/02/2017] [Accepted: 01/03/2017] [Indexed: 05/18/2023]
Abstract
Imaging speed is one of the most important parameters that define the performance of optical coherence tomography (OCT) systems. During the last two decades, OCT speed has increased by over three orders of magnitude. New developments in wavelength-swept lasers have repeatedly been crucial for this development. In this review, we discuss the historical evolution and current state of the art of high-speed OCT systems, with focus on wavelength swept light sources and swept source OCT systems.
Collapse
Affiliation(s)
- Thomas Klein
- Optores GmbH, Gollierstr. 70, 80339 Munich, Germany
| | - Robert Huber
- Institut für Biomedizinische Optik, Universität zu Lübeck, Peter-Monnik-Weg 4, 23562 Lübeck, Germany
| |
Collapse
|