101
|
Orlando JI, Prokofyeva E, Del Fresno M, Blaschko MB. An ensemble deep learning based approach for red lesion detection in fundus images. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2018; 153:115-127. [PMID: 29157445 DOI: 10.1016/j.cmpb.2017.10.017] [Citation(s) in RCA: 91] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/23/2017] [Revised: 09/06/2017] [Accepted: 10/12/2017] [Indexed: 05/23/2023]
Abstract
BACKGROUND AND OBJECTIVES Diabetic retinopathy (DR) is one of the leading causes of preventable blindness in the world. Its earliest sign are red lesions, a general term that groups both microaneurysms (MAs) and hemorrhages (HEs). In daily clinical practice, these lesions are manually detected by physicians using fundus photographs. However, this task is tedious and time consuming, and requires an intensive effort due to the small size of the lesions and their lack of contrast. Computer-assisted diagnosis of DR based on red lesion detection is being actively explored due to its improvement effects both in clinicians consistency and accuracy. Moreover, it provides comprehensive feedback that is easy to assess by the physicians. Several methods for detecting red lesions have been proposed in the literature, most of them based on characterizing lesion candidates using hand crafted features, and classifying them into true or false positive detections. Deep learning based approaches, by contrast, are scarce in this domain due to the high expense of annotating the lesions manually. METHODS In this paper we propose a novel method for red lesion detection based on combining both deep learned and domain knowledge. Features learned by a convolutional neural network (CNN) are augmented by incorporating hand crafted features. Such ensemble vector of descriptors is used afterwards to identify true lesion candidates using a Random Forest classifier. RESULTS We empirically observed that combining both sources of information significantly improve results with respect to using each approach separately. Furthermore, our method reported the highest performance on a per-lesion basis on DIARETDB1 and e-ophtha, and for screening and need for referral on MESSIDOR compared to a second human expert. CONCLUSIONS Results highlight the fact that integrating manually engineered approaches with deep learned features is relevant to improve results when the networks are trained from lesion-level annotated data. An open source implementation of our system is publicly available at https://github.com/ignaciorlando/red-lesion-detection.
Collapse
Affiliation(s)
- José Ignacio Orlando
- Pladema Institute, UNCPBA, Gral. Pinto 399, Tandil, Argentina; Consejo Nacional de Investigaciones Científicas y Técnicas, CONICET, Argentina.
| | - Elena Prokofyeva
- Scientific Institute of Public Health (WIV-ISP), Brussels, Belgium; Federal Agency for Medicines and Health Products (FAMHP), Brussels, Belgium
| | - Mariana Del Fresno
- Pladema Institute, UNCPBA, Gral. Pinto 399, Tandil, Argentina; Comisión de Investigaciones Científicas de la Provincia de Buenos Aires, CIC-PBA, Buenos Aires, Argentina
| | | |
Collapse
|
102
|
Budak U, Şengür A, Guo Y, Akbulut Y. A novel microaneurysms detection approach based on convolutional neural networks with reinforcement sample learning algorithm. Health Inf Sci Syst 2017; 5:14. [PMID: 29147563 DOI: 10.1007/s13755-017-0034-9] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2017] [Accepted: 10/25/2017] [Indexed: 01/02/2023] Open
Abstract
Microaneurysms (MAs) are known as early signs of diabetic-retinopathy which are called red lesions in color fundus images. Detection of MAs in fundus images needs highly skilled physicians or eye angiography. Eye angiography is an invasive and expensive procedure. Therefore, an automatic detection system to identify the MAs locations in fundus images is in demand. In this paper, we proposed a system to detect the MAs in colored fundus images. The proposed method composed of three stages. In the first stage, a series of pre-processing steps are used to make the input images more convenient for MAs detection. To this end, green channel decomposition, Gaussian filtering, median filtering, back ground determination, and subtraction operations are applied to input colored fundus images. After pre-processing, a candidate MAs extraction procedure is applied to detect potential regions. A five-stepped procedure is adopted to get the potential MA locations. Finally, deep convolutional neural network (DCNN) with reinforcement sample learning strategy is used to train the proposed system. The DCNN is trained with color image patches which are collected from ground-truth MA locations and non-MA locations. We conducted extensive experiments on ROC dataset to evaluate of our proposal. The results are encouraging.
Collapse
Affiliation(s)
- Umit Budak
- Electrical-Electronics Engineering Department, Engineering Faculty, Bitlis Eren University, Bitlis, Turkey
| | - Abdulkadir Şengür
- Electrical and Electronics Engineering Department, Technology Faculty, Firat University, Elazig, Turkey
| | - Yanhui Guo
- Department of Computer Science, University of Illinois, Springfield, IL USA
| | - Yaman Akbulut
- Electrical and Electronics Engineering Department, Technology Faculty, Firat University, Elazig, Turkey
| |
Collapse
|
103
|
Koh JEW, Ng EYK, Bhandary SV, Laude A, Acharya UR. Automated detection of retinal health using PHOG and SURF features extracted from fundus images. APPL INTELL 2017. [DOI: 10.1007/s10489-017-1048-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
104
|
Soomro TA, Gao J, Khan T, Hani AFM, Khan MAU, Paul M. Computerised approaches for the detection of diabetic retinopathy using retinal fundus images: a survey. Pattern Anal Appl 2017. [DOI: 10.1007/s10044-017-0630-y] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
105
|
Veiga D, Martins N, Ferreira M, Monteiro J. Automatic microaneurysm detection using laws texture masks and support vector machines. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION 2017. [DOI: 10.1080/21681163.2017.1296379] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Affiliation(s)
- Diana Veiga
- Enermeter, Braga, Portugal
- Centro Algoritmi, University of Minho, Guimarães, Portugal
| | | | | | - João Monteiro
- Centro Algoritmi, University of Minho, Guimarães, Portugal
| |
Collapse
|
106
|
Holm S, Russell G, Nourrit V, McLoughlin N. DR HAGIS-a fundus image database for the automatic extraction of retinal surface vessels from diabetic patients. J Med Imaging (Bellingham) 2017; 4:014503. [PMID: 28217714 DOI: 10.1117/1.jmi.4.1.014503] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2016] [Accepted: 01/16/2017] [Indexed: 11/14/2022] Open
Abstract
A database of retinal fundus images, the DR HAGIS database, is presented. This database consists of 39 high-resolution color fundus images obtained from a diabetic retinopathy screening program in the UK. The NHS screening program uses service providers that employ different fundus and digital cameras. This results in a range of different image sizes and resolutions. Furthermore, patients enrolled in such programs often display other comorbidities in addition to diabetes. Therefore, in an effort to replicate the normal range of images examined by grading experts during screening, the DR HAGIS database consists of images of varying image sizes and resolutions and four comorbidity subgroups: collectively defined as the diabetic retinopathy, hypertension, age-related macular degeneration, and Glaucoma image set (DR HAGIS). For each image, the vasculature has been manually segmented to provide a realistic set of images on which to test automatic vessel extraction algorithms. Modified versions of two previously published vessel extraction algorithms were applied to this database to provide some baseline measurements. A method based purely on the intensity of images pixels resulted in a mean segmentation accuracy of 95.83% ([Formula: see text]), whereas an algorithm based on Gabor filters generated an accuracy of 95.71% ([Formula: see text]).
Collapse
Affiliation(s)
- Sven Holm
- University of Manchester , Faculty of Biology, Medicine and Health, Division of Pharmacy and Optometry, Manchester, United Kingdom
| | - Greg Russell
- University of Manchester , Faculty of Biology, Medicine and Health, Division of Pharmacy and Optometry, Manchester, United Kingdom
| | - Vincent Nourrit
- Telecom Bretagne , Département d'Optique Technopôle Brest-Iroise, Brest, France
| | - Niall McLoughlin
- University of Manchester , Faculty of Biology, Medicine and Health, Division of Pharmacy and Optometry, Manchester, United Kingdom
| |
Collapse
|
107
|
Javidi M, Pourreza HR, Harati A. Vessel segmentation and microaneurysm detection using discriminative dictionary learning and sparse representation. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2017; 139:93-108. [PMID: 28187898 DOI: 10.1016/j.cmpb.2016.10.015] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/28/2016] [Revised: 09/22/2016] [Accepted: 10/18/2016] [Indexed: 06/06/2023]
Abstract
Diabetic retinopathy (DR) is a major cause of visual impairment, and the analysis of retinal image can assist patients to take action earlier when it is more likely to be effective. The accurate segmentation of blood vessels in the retinal image can diagnose DR directly. In this paper, a novel scheme for blood vessel segmentation based on discriminative dictionary learning (DDL) and sparse representation has been proposed. The proposed system yields a strong representation which contains the semantic concept of the image. To extract blood vessel, two separate dictionaries, for vessel and non-vessel, capable of providing reconstructive and discriminative information of the retinal image are learned. In the test step, an unseen retinal image is divided into overlapping patches and classified to vessel and non-vessel patches. Then, a voting scheme is applied to generate the binary vessel map. The proposed vessel segmentation method can achieve the accuracy of 95% and a sensitivity of 75% in the same range of specificity 97% on two public datasets. The results show that the proposed method can achieve comparable results to existing methods and decrease false positive vessels in abnormal retinal images with pathological regions. Microaneurysm (MA) is the earliest sign of DR that appears as a small red dot on the surface of the retina. Despite several attempts to develop automated MA detection systems, it is still a challenging problem. In this paper, a method for MA detection, which is similar to our vessel segmentation approach, is proposed. In our method, a candidate detection algorithm based on the Morlet wavelet is applied to identify all possible MA candidates. In the next step, two discriminative dictionaries with the ability to distinguish MA from non-MA object are learned. These dictionaries are then used to classify the detected candidate objects. The evaluations indicate that the proposed MA detection method achieves higher average sensitivity about 2-15%, compared to existing methods.
Collapse
Affiliation(s)
- Malihe Javidi
- Faculty of Computer Engineering, Ferdowsi University of Mashhad, Mashhad, Iran; Machine Vision Lab, Eye Image Analysis Research Group (EIARG), Ferdowsi University of Mashhad, Mashhad, Iran
| | - Hamid-Reza Pourreza
- Faculty of Computer Engineering, Ferdowsi University of Mashhad, Mashhad, Iran; Machine Vision Lab, Eye Image Analysis Research Group (EIARG), Ferdowsi University of Mashhad, Mashhad, Iran.
| | - Ahad Harati
- Faculty of Computer Engineering, Ferdowsi University of Mashhad, Mashhad, Iran; Robot Perception Lab, Ferdowsi University of Mashhad, Mashhad, Iran
| |
Collapse
|
108
|
Habib M, Welikala R, Hoppe A, Owen C, Rudnicka A, Barman S. Detection of microaneurysms in retinal images using an ensemble classifier. INFORMATICS IN MEDICINE UNLOCKED 2017. [DOI: 10.1016/j.imu.2017.05.006] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
|
109
|
Srivastava R, Duan L, Wong DWK, Liu J, Wong TY. Detecting retinal microaneurysms and hemorrhages with robustness to the presence of blood vessels. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2017; 138:83-91. [PMID: 27886718 DOI: 10.1016/j.cmpb.2016.10.017] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/29/2016] [Revised: 09/05/2016] [Accepted: 10/18/2016] [Indexed: 06/06/2023]
Abstract
BACKGROUND AND OBJECTIVES Diabetic Retinopathy is the leading cause of blindness in developed countries in the age group 20-74 years. It is characterized by lesions on the retina and this paper focuses on detecting two of these lesions, Microaneurysms and Hemorrhages, which are also known as red lesions. This paper attempts to deal with two problems in detecting red lesions from retinal fundus images: (1) false detections on blood vessels; and (2) different size of red lesions. METHODS To deal with false detections on blood vessels, novel filters have been proposed which can distinguish between red lesions and blood vessels. This distinction is based on the fact that vessels are elongated while red lesions are usually circular blob-like structures. The second problem of the different size of lesions is dealt with by applying the proposed filters on patches of different sizes instead of filtering the full image. These patches are obtained by dividing the original image using a grid whose size determines the patch size. Different grid sizes were used and lesion detection results for these grid sizes were combined using Multiple Kernel Learning. RESULTS Experiments on a dataset of 143 images showed that proposed filters detected Microaneurysms and Hemorrhages successfully even when these lesions were close to blood vessels. In addition, using Multiple Kernel Learning improved the results when compared to using a grid of one size only. The areas under receiver operating characteristic curve were found to be 0.97 and 0.92 for Microaneurysms and Hemorrhages respectively which are better than the existing related works. CONCLUSIONS Proposed filters are robust to the presence of blood vessels and surpass related works in detecting red lesions from retinal fundus images. Improved lesion detection using the proposed approach can help in automatic detection of Diabetic Retinopathy.
Collapse
Affiliation(s)
| | - Lixin Duan
- Institute for Infocomm Research, Singapore 138632
| | | | - Jiang Liu
- Institute for Infocomm Research, Singapore 138632
| | | |
Collapse
|
110
|
Pires R, Avila S, Jelinek HF, Wainer J, Valle E, Rocha A. Beyond Lesion-Based Diabetic Retinopathy: A Direct Approach for Referral. IEEE J Biomed Health Inform 2017; 21:193-200. [DOI: 10.1109/jbhi.2015.2498104] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
111
|
Robust and accurate optic disk localization using vessel symmetry line measure in fundus images. Biocybern Biomed Eng 2017. [DOI: 10.1016/j.bbe.2017.05.008] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
112
|
Ren F, Cao P, Li W, Zhao D, Zaiane O. Ensemble based adaptive over-sampling method for imbalanced data learning in computer aided detection of microaneurysm. Comput Med Imaging Graph 2017; 55:54-67. [DOI: 10.1016/j.compmedimag.2016.07.011] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2016] [Revised: 06/17/2016] [Accepted: 07/29/2016] [Indexed: 10/21/2022]
|
113
|
Valverde C, Garcia M, Hornero R, Lopez-Galvez MI. Automated detection of diabetic retinopathy in retinal images. Indian J Ophthalmol 2016; 64:26-32. [PMID: 26953020 PMCID: PMC4821117 DOI: 10.4103/0301-4738.178140] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
Diabetic retinopathy (DR) is a disease with an increasing prevalence and the main cause of blindness among working-age population. The risk of severe vision loss can be significantly reduced by timely diagnosis and treatment. Systematic screening for DR has been identified as a cost-effective way to save health services resources. Automatic retinal image analysis is emerging as an important screening tool for early DR detection, which can reduce the workload associated to manual grading as well as save diagnosis costs and time. Many research efforts in the last years have been devoted to developing automatic tools to help in the detection and evaluation of DR lesions. However, there is a large variability in the databases and evaluation criteria used in the literature, which hampers a direct comparison of the different studies. This work is aimed at summarizing the results of the available algorithms for the detection and classification of DR pathology. A detailed literature search was conducted using PubMed. Selected relevant studies in the last 10 years were scrutinized and included in the review. Furthermore, we will try to give an overview of the available commercial software for automatic retinal image analysis.
Collapse
Affiliation(s)
- Carmen Valverde
- Department of Ophthalmology, Hospital de Medina del Campo, Medina del Campo, Valladolid, Spain
| | | | | | | |
Collapse
|
114
|
Rahim SS, Palade V, Shuttleworth J, Jayne C. Automatic screening and classification of diabetic retinopathy and maculopathy using fuzzy image processing. Brain Inform 2016; 3:249-267. [PMID: 27747815 PMCID: PMC5106407 DOI: 10.1007/s40708-016-0045-3] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2015] [Accepted: 02/24/2016] [Indexed: 10/29/2022] Open
Abstract
Digital retinal imaging is a challenging screening method for which effective, robust and cost-effective approaches are still to be developed. Regular screening for diabetic retinopathy and diabetic maculopathy diseases is necessary in order to identify the group at risk of visual impairment. This paper presents a novel automatic detection of diabetic retinopathy and maculopathy in eye fundus images by employing fuzzy image processing techniques. The paper first introduces the existing systems for diabetic retinopathy screening, with an emphasis on the maculopathy detection methods. The proposed medical decision support system consists of four parts, namely: image acquisition, image preprocessing including four retinal structures localisation, feature extraction and the classification of diabetic retinopathy and maculopathy. A combination of fuzzy image processing techniques, the Circular Hough Transform and several feature extraction methods are implemented in the proposed system. The paper also presents a novel technique for the macula region localisation in order to detect the maculopathy. In addition to the proposed detection system, the paper highlights a novel online dataset and it presents the dataset collection, the expert diagnosis process and the advantages of our online database compared to other public eye fundus image databases for diabetic retinopathy purposes.
Collapse
Affiliation(s)
- Sarni Suhaila Rahim
- Faculty of Engineering, Environment and Computing, Coventry University, Priory Street, Coventry, CV1 5FB UK
- Faculty of Information and Communication Technology, Universiti Teknikal Malaysia Melaka, Hang Tuah Jaya, 76100 Durian Tunggal, Melaka Malaysia
| | - Vasile Palade
- Faculty of Engineering, Environment and Computing, Coventry University, Priory Street, Coventry, CV1 5FB UK
| | - James Shuttleworth
- Faculty of Engineering, Environment and Computing, Coventry University, Priory Street, Coventry, CV1 5FB UK
| | - Chrisina Jayne
- Faculty of Engineering, Environment and Computing, Coventry University, Priory Street, Coventry, CV1 5FB UK
| |
Collapse
|
115
|
Farahani K, Kalpathy-Cramer J, Chenevert TL, Rubin DL, Sunderland JJ, Nordstrom RJ, Buatti J, Hylton N. Computational Challenges and Collaborative Projects in the NCI Quantitative Imaging Network. Tomography 2016; 2:242-249. [PMID: 28798963 PMCID: PMC5548142 DOI: 10.18383/j.tom.2016.00265] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
The Quantitative Imaging Network (QIN) of the National Cancer Institute (NCI) conducts research in development and validation of imaging tools and methods for predicting and evaluating clinical response to cancer therapy. Members of the network are involved in examining various imaging and image assessment parameters through network-wide cooperative projects. To more effectively use the cooperative power of the network in conducting computational challenges in benchmarking of tools and methods and collaborative projects in analytical assessment of imaging technologies, the QIN Challenge Task Force has developed policies and procedures to enhance the value of these activities by developing guidelines and leveraging NCI resources to help their administration and manage dissemination of results. Challenges and Collaborative Projects (CCPs) are further divided into technical and clinical CCPs. As the first NCI network to engage in CCPs, we anticipate a variety of CCPs to be conducted by QIN teams in the coming years. These will be aimed to benchmark advanced software tools for clinical decision support, explore new imaging biomarkers for therapeutic assessment, and establish consensus on a range of methods and protocols in support of the use of quantitative imaging to predict and assess response to cancer therapy.
Collapse
Affiliation(s)
- Keyvan Farahani
- Cancer Imaging Program, National Cancer Institute, Bethesda, Maryland
| | | | | | - Daniel L. Rubin
- Department of Radiology, Biomedical Data Science, and Medicine (Biomedical Informatics Research), Stanford University, Palo Alto, California
| | | | | | - John Buatti
- Department of Radiation Oncology, University of Iowa, Iowa City, Iowa; and
| | - Nola Hylton
- Department of Radiology, University of California San Francisco, San Francisco, California
| |
Collapse
|
116
|
Besenczi R, Tóth J, Hajdu A. A review on automatic analysis techniques for color fundus photographs. Comput Struct Biotechnol J 2016; 14:371-384. [PMID: 27800125 PMCID: PMC5072151 DOI: 10.1016/j.csbj.2016.10.001] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2016] [Revised: 10/01/2016] [Accepted: 10/03/2016] [Indexed: 12/25/2022] Open
Abstract
In this paper, we give a review on automatic image processing tools to recognize diseases causing specific distortions in the human retina. After a brief summary of the biology of the retina, we give an overview of the types of lesions that may appear as biomarkers of both eye and non-eye diseases. We present several state-of-the-art procedures to extract the anatomic components and lesions in color fundus photographs and decision support methods to help clinical diagnosis. We list publicly available databases and appropriate measurement techniques to compare quantitatively the performance of these approaches. Furthermore, we discuss on how the performance of image processing-based systems can be improved by fusing the output of individual detector algorithms. Retinal image analysis using mobile phones is also addressed as an expected future trend in this field.
Collapse
Key Words
- ACC, accuracy
- AMD, age-related macular degeneration
- AUC, area under the receiver operator characteristics curve
- Biomedical imaging
- Clinical decision support
- DR, diabetic retinopathy
- FN, false negative
- FOV, field-of-view
- FP, false positive
- FPI, false positive per image
- Fundus image analysis
- MA, microaneurysm
- NA, not available
- OC, optic cup
- OD, optic disc
- PPV, positive predictive value (precision)
- ROC, Retinopathy Online Challenge
- RS, Retinopathy Online Challenge score
- Retinal diseases
- SCC, Spearman's rank correlation coefficient
- SE, sensitivity
- SP, specificity
- TN, true negative
- TP, true positive
- kNN, k-nearest neighbor
Collapse
Affiliation(s)
- Renátó Besenczi
- Faculty of Informatics, University of Debrecen 4002 Debrecen PO Box 400, Hungary
| | - János Tóth
- Faculty of Informatics, University of Debrecen 4002 Debrecen PO Box 400, Hungary
| | - András Hajdu
- Faculty of Informatics, University of Debrecen 4002 Debrecen PO Box 400, Hungary
| |
Collapse
|
117
|
Ali Shah SA, Laude A, Faye I, Tang TB. Automated microaneurysm detection in diabetic retinopathy using curvelet transform. JOURNAL OF BIOMEDICAL OPTICS 2016; 21:101404. [PMID: 26868326 DOI: 10.1117/1.jbo.21.10.101404] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/04/2015] [Accepted: 01/18/2016] [Indexed: 06/05/2023]
Abstract
Microaneurysms (MAs) are known to be the early signs of diabetic retinopathy (DR). An automated MA detection system based on curvelet transform is proposed for color fundus image analysis. Candidates of MA were extracted in two parallel steps. In step one, blood vessels were removed from preprocessed green band image and preliminary MA candidates were selected by local thresholding technique. In step two, based on statistical features, the image background was estimated. The results from the two steps allowed us to identify preliminary MA candidates which were also present in the image foreground. A collection set of features was fed to a rule-based classifier to divide the candidates into MAs and non-MAs. The proposed system was tested with Retinopathy Online Challenge database. The automated system detected 162 MAs out of 336, thus achieved a sensitivity of 48.21% with 65 false positives per image. Counting MA is a means to measure the progression of DR. Hence, the proposed system may be deployed to monitor the progression of DR at early stage in population studies.
Collapse
Affiliation(s)
- Syed Ayaz Ali Shah
- Universiti Teknologi PETRONAS, Department of Electrical and Electronic Engineering, Centre for Intelligent Signal and Imaging Research, Bandar Seri Iskandar, Perak 32610, Malaysia
| | - Augustinus Laude
- National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore 308433, Singapore
| | - Ibrahima Faye
- Universiti Teknologi PETRONAS, Department of Fundamental and Applied Sciences, Centre for Intelligent Signal and Imaging Research, Bandar Seri Iskandar, Perak 32610, Malaysia
| | - Tong Boon Tang
- Universiti Teknologi PETRONAS, Department of Electrical and Electronic Engineering, Centre for Intelligent Signal and Imaging Research, Bandar Seri Iskandar, Perak 32610, Malaysia
| |
Collapse
|
118
|
Amin J, Sharif M, Yasmin M. A Review on Recent Developments for Detection of Diabetic Retinopathy. SCIENTIFICA 2016; 2016:6838976. [PMID: 27777811 PMCID: PMC5061953 DOI: 10.1155/2016/6838976] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2015] [Revised: 04/22/2016] [Accepted: 05/10/2016] [Indexed: 06/01/2023]
Abstract
Diabetic retinopathy is caused by the retinal micro vasculature which may be formed as a result of diabetes mellitus. Blindness may appear as a result of unchecked and severe cases of diabetic retinopathy. Manual inspection of fundus images to check morphological changes in microaneurysms, exudates, blood vessels, hemorrhages, and macula is a very time-consuming and tedious work. It can be made easily with the help of computer-aided system and intervariability for the observer. In this paper, several techniques for detecting microaneurysms, hemorrhages, and exudates are discussed for ultimate detection of nonproliferative diabetic retinopathy. Blood vessels detection techniques are also discussed for the diagnosis of proliferative diabetic retinopathy. Furthermore, the paper elaborates a discussion on the experiments accessed by authors for the detection of diabetic retinopathy. This work will be helpful for the researchers and technical persons who want to utilize the ongoing research in this area.
Collapse
Affiliation(s)
- Javeria Amin
- COMSATS Institute of Information Technology, Department of Computer Science, Wah 47040, Pakistan
| | - Muhammad Sharif
- COMSATS Institute of Information Technology, Department of Computer Science, Wah 47040, Pakistan
| | - Mussarat Yasmin
- COMSATS Institute of Information Technology, Department of Computer Science, Wah 47040, Pakistan
| |
Collapse
|
119
|
Leifman G, Swedish T, Roesch K, Raskar R. Leveraging the crowd for annotation of retinal images. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2015:7736-9. [PMID: 26738085 DOI: 10.1109/embc.2015.7320185] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Medical data presents a number of challenges. It tends to be unstructured, noisy and protected. To train algorithms to understand medical images, doctors can label the condition associated with a particular image, but obtaining enough labels can be difficult. We propose an annotation approach which starts with a small pool of expertly annotated images and uses their expertise to rate the performance of crowd-sourced annotations. In this paper we demonstrate how to apply our approach for annotation of large-scale datasets of retinal images. We introduce a novel data validation procedure which is designed to cope with noisy ground-truth data and with non-consistent input from both experts and crowd-workers.
Collapse
|
120
|
Wu X, Dai B, Bu W. Optic Disc Localization Using Directional Models. IEEE TRANSACTIONS ON IMAGE PROCESSING : A PUBLICATION OF THE IEEE SIGNAL PROCESSING SOCIETY 2016; 25:4433-4442. [PMID: 27416600 DOI: 10.1109/tip.2016.2590838] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Reliable localization of the optic disc (OD) is important for retinal image analysis and ophthalmic pathology screening. This paper presents a novel method to automatically localize ODs in retinal fundus images based on directional models. According to the characteristics of retina vessel networks, such as their origin at the OD and parabolic shape of the main vessels, a global directional model, named the relaxed biparabola directional model, is first built. In this model, the main vessels are modeled by using two parabolas with a shared vertex and different parameters. Then, a local directional model, named the disc directional model, is built to characterize the local vessel convergence in the OD as well as the shape and the brightness of the OD. Finally, the global and the local directional models are integrated to form a hybrid directional model, which can exploit the advantages of the global and local models for highly accurate OD localization. The proposed method is evaluated on nine publicly available databases, and achieves an accuracy of 100% for each database, which demonstrates the effectiveness of the proposed OD localization method.
Collapse
|
121
|
Dai B, Wu X, Bu W. Retinal Microaneurysms Detection Using Gradient Vector Analysis and Class Imbalance Classification. PLoS One 2016; 11:e0161556. [PMID: 27564376 PMCID: PMC5001638 DOI: 10.1371/journal.pone.0161556] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2015] [Accepted: 07/09/2016] [Indexed: 11/24/2022] Open
Abstract
Retinal microaneurysms (MAs) are the earliest clinically observable lesions of diabetic retinopathy. Reliable automated MAs detection is thus critical for early diagnosis of diabetic retinopathy. This paper proposes a novel method for the automated MAs detection in color fundus images based on gradient vector analysis and class imbalance classification, which is composed of two stages, i.e. candidate MAs extraction and classification. In the first stage, a candidate MAs extraction algorithm is devised by analyzing the gradient field of the image, in which a multi-scale log condition number map is computed based on the gradient vectors for vessel removal, and then the candidate MAs are localized according to the second order directional derivatives computed in different directions. Due to the complexity of fundus image, besides a small number of true MAs, there are also a large amount of non-MAs in the extracted candidates. Classifying the true MAs and the non-MAs is an extremely class imbalanced classification problem. Therefore, in the second stage, several types of features including geometry, contrast, intensity, edge, texture, region descriptors and other features are extracted from the candidate MAs and a class imbalance classifier, i.e., RUSBoost, is trained for the MAs classification. With the Retinopathy Online Challenge (ROC) criterion, the proposed method achieves an average sensitivity of 0.433 at 1/8, 1/4, 1/2, 1, 2, 4 and 8 false positives per image on the ROC database, which is comparable with the state-of-the-art approaches, and 0.321 on the DiaRetDB1 V2.1 database, which outperforms the state-of-the-art approaches.
Collapse
Affiliation(s)
- Baisheng Dai
- School of Computer Science and Technology, Harbin Institute of Technology, Harbin, China
| | - Xiangqian Wu
- School of Computer Science and Technology, Harbin Institute of Technology, Harbin, China
| | - Wei Bu
- Department of New Media Technologies and Arts, Harbin Institute of Technology, Harbin, China
| |
Collapse
|
122
|
Shahrian Varnousfaderani E, Wu J, Vogl WD, Philip AM, Montuoro A, Leitner R, Simader C, Waldstein SM, Gerendas BS, Schmidt-Erfurth U. A novel benchmark model for intelligent annotation of spectral-domain optical coherence tomography scans using the example of cyst annotation. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2016; 130:93-105. [PMID: 27208525 DOI: 10.1016/j.cmpb.2016.03.012] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/21/2015] [Revised: 02/05/2016] [Accepted: 03/10/2016] [Indexed: 06/05/2023]
Abstract
BACKGROUND AND OBJECTIVES The lack of benchmark data in computational ophthalmology contributes to the challenging task of applying disease assessment and evaluate performance of machine learning based methods on retinal spectral domain optical coherence tomography (SD-OCT) scans. Presented here is a general framework for constructing a benchmark dataset for retinal image processing tasks such as cyst, vessel, and subretinal fluid segmentation and as a result, a benchmark dataset for cyst segmentation has been developed. METHOD First, a dataset captured by different SD-OCT vendors with different numbers of scans and pathology qualities are selected. Then a robust and intelligent method is used to evaluate performance of readers, partitioning the dataset into subsets. Subsets are then assigned to complementary readers for annotation with respect to a novel confidence based annotation protocol. Finally, reader annotations are combined based on their performance to generate final annotations. RESULT The generated benchmark dataset for cyst segmentation comprises 26 SD-OCT scans with differing cyst qualities, collected from 4 different SD-OCT vendors to cover a wide variety of data. The dataset is partitioned into three subsets which are annotated by complementary readers based on a confidence based annotation protocol. Experimental results show annotations of complementary readers are combined efficiently with respect to their performance, generating accurate annotations. CONCLUSION Our results facilitate the process of generating benchmark datasets. Moreover the generated benchmark data set for cyst segmentation can be used reliably to train and test machine learning based methods.
Collapse
Affiliation(s)
- Ehsan Shahrian Varnousfaderani
- Christian Doppler Laboratory for Ophthalmic Image Analysis, Vienna Reading Center, Department of Ophthalmology, Medical University of Vienna, Vienna, Austria
| | - Jing Wu
- Christian Doppler Laboratory for Ophthalmic Image Analysis, Vienna Reading Center, Department of Ophthalmology, Medical University of Vienna, Vienna, Austria
| | - Wolf-Dieter Vogl
- Christian Doppler Laboratory for Ophthalmic Image Analysis, Vienna Reading Center, Department of Ophthalmology, Medical University of Vienna, Vienna, Austria
| | - Ana-Maria Philip
- Christian Doppler Laboratory for Ophthalmic Image Analysis, Vienna Reading Center, Department of Ophthalmology, Medical University of Vienna, Vienna, Austria
| | - Alessio Montuoro
- Christian Doppler Laboratory for Ophthalmic Image Analysis, Vienna Reading Center, Department of Ophthalmology, Medical University of Vienna, Vienna, Austria
| | - Roland Leitner
- Christian Doppler Laboratory for Ophthalmic Image Analysis, Vienna Reading Center, Department of Ophthalmology, Medical University of Vienna, Vienna, Austria
| | - Christian Simader
- Christian Doppler Laboratory for Ophthalmic Image Analysis, Vienna Reading Center, Department of Ophthalmology, Medical University of Vienna, Vienna, Austria
| | - Sebastian M Waldstein
- Christian Doppler Laboratory for Ophthalmic Image Analysis, Vienna Reading Center, Department of Ophthalmology, Medical University of Vienna, Vienna, Austria
| | - Bianca S Gerendas
- Christian Doppler Laboratory for Ophthalmic Image Analysis, Vienna Reading Center, Department of Ophthalmology, Medical University of Vienna, Vienna, Austria.
| | - Ursula Schmidt-Erfurth
- Christian Doppler Laboratory for Ophthalmic Image Analysis, Vienna Reading Center, Department of Ophthalmology, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
123
|
Wang S, Tang HL, Al Turk LI, Hu Y, Sanei S, Saleh GM, Peto T. Localizing Microaneurysms in Fundus Images Through Singular Spectrum Analysis. IEEE Trans Biomed Eng 2016; 64:990-1002. [PMID: 27362756 DOI: 10.1109/tbme.2016.2585344] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
GOAL Reliable recognition of microaneurysms (MAs) is an essential task when developing an automated analysis system for diabetic retinopathy (DR) detection. In this study, we propose an integrated approach for automated MA detection with high accuracy. METHODS Candidate objects are first located by applying a dark object filtering process. Their cross-section profiles along multiple directions are processed through singular spectrum analysis. The correlation coefficient between each processed profile and a typical MA profile is measured and used as a scale factor to adjust the shape of the candidate profile. This is to increase the difference in their profiles between true MAs and other non-MA candidates. A set of statistical features of those profiles is then extracted for a K-nearest neighbor classifier. RESULTS Experiments show that by applying this process, MAs can be separated well from the retinal background, the most common interfering objects and artifacts. CONCLUSION The results have demonstrated the robustness of the approach when testing on large scale datasets with clinically acceptable sensitivity and specificity. SIGNIFICANCE The approach proposed in the evaluated system has great potential when used in an automated DR screening tool or for large scale eye epidemiology studies.
Collapse
|
124
|
Seoud L, Hurtut T, Chelbi J, Cheriet F, Langlois JMP. Red Lesion Detection Using Dynamic Shape Features for Diabetic Retinopathy Screening. IEEE TRANSACTIONS ON MEDICAL IMAGING 2016; 35:1116-26. [PMID: 26701180 DOI: 10.1109/tmi.2015.2509785] [Citation(s) in RCA: 103] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
The development of an automatic telemedicine system for computer-aided screening and grading of diabetic retinopathy depends on reliable detection of retinal lesions in fundus images. In this paper, a novel method for automatic detection of both microaneurysms and hemorrhages in color fundus images is described and validated. The main contribution is a new set of shape features, called Dynamic Shape Features, that do not require precise segmentation of the regions to be classified. These features represent the evolution of the shape during image flooding and allow to discriminate between lesions and vessel segments. The method is validated per-lesion and per-image using six databases, four of which are publicly available. It proves to be robust with respect to variability in image resolution, quality and acquisition system. On the Retinopathy Online Challenge's database, the method achieves a FROC score of 0.420 which ranks it fourth. On the Messidor database, when detecting images with diabetic retinopathy, the proposed method achieves an area under the ROC curve of 0.899, comparable to the score of human experts, and it outperforms state-of-the-art approaches.
Collapse
|
125
|
Kovács G, Hajdu A. A self-calibrating approach for the segmentation of retinal vessels by template matching and contour reconstruction. Med Image Anal 2016; 29:24-46. [DOI: 10.1016/j.media.2015.12.003] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2014] [Revised: 12/01/2015] [Accepted: 12/03/2015] [Indexed: 01/17/2023]
|
126
|
Soares I, Castelo-Branco M, Pinheiro AMG. Optic Disc Localization in Retinal Images Based on Cumulative Sum Fields. IEEE J Biomed Health Inform 2016; 20:574-85. [DOI: 10.1109/jbhi.2015.2392712] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
127
|
Riedl C, Zanibbi R, Hearst MA, Zhu S, Menietti M, Crusan J, Metelsky I, Lakhani KR. Detecting figures and part labels in patents: competition-based development of graphics recognition algorithms. INT J DOC ANAL RECOG 2016. [DOI: 10.1007/s10032-016-0260-8] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
128
|
Yang JJ, Li J, Shen R, Zeng Y, He J, Bi J, Li Y, Zhang Q, Peng L, Wang Q. Exploiting ensemble learning for automatic cataract detection and grading. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2016; 124:45-57. [PMID: 26563686 DOI: 10.1016/j.cmpb.2015.10.007] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/24/2015] [Revised: 10/05/2015] [Accepted: 10/14/2015] [Indexed: 06/05/2023]
Abstract
Cataract is defined as a lenticular opacity presenting usually with poor visual acuity. It is one of the most common causes of visual impairment worldwide. Early diagnosis demands the expertise of trained healthcare professionals, which may present a barrier to early intervention due to underlying costs. To date, studies reported in the literature utilize a single learning model for retinal image classification in grading cataract severity. We present an ensemble learning based approach as a means to improving diagnostic accuracy. Three independent feature sets, i.e., wavelet-, sketch-, and texture-based features, are extracted from each fundus image. For each feature set, two base learning models, i.e., Support Vector Machine and Back Propagation Neural Network, are built. Then, the ensemble methods, majority voting and stacking, are investigated to combine the multiple base learning models for final fundus image classification. Empirical experiments are conducted for cataract detection (two-class task, i.e., cataract or non-cataractous) and cataract grading (four-class task, i.e., non-cataractous, mild, moderate or severe) tasks. The best performance of the ensemble classifier is 93.2% and 84.5% in terms of the correct classification rates for cataract detection and grading tasks, respectively. The results demonstrate that the ensemble classifier outperforms the single learning model significantly, which also illustrates the effectiveness of the proposed approach.
Collapse
Affiliation(s)
- Ji-Jiang Yang
- Tsinghua National Laboratory for Information Science and Technology, Tsinghua University, Beijing, China.
| | - Jianqiang Li
- School of Software Engineering, Beijing University of Technology, Beijing, China.
| | - Ruifang Shen
- Tsinghua National Laboratory for Information Science and Technology, Tsinghua University, Beijing, China.
| | - Yang Zeng
- Automation School, Beijing University of Posts and Telecommunications, Beijing 100876, China.
| | - Jian He
- School of Software Engineering, Beijing University of Technology, Beijing, China.
| | - Jing Bi
- School of Software Engineering, Beijing University of Technology, Beijing, China.
| | - Yong Li
- School of Software Engineering, Beijing University of Technology, Beijing, China.
| | - Qinyan Zhang
- Automation School, Beijing University of Posts and Telecommunications, Beijing 100876, China.
| | - Lihui Peng
- Tsinghua National Laboratory for Information Science and Technology, Tsinghua University, Beijing, China.
| | - Qing Wang
- Research Institute of Application Technology in Wuxi, Tsinghua University, Jiangsu, China.
| |
Collapse
|
129
|
Quellec G, Lamard M, Erginay A, Chabouis A, Massin P, Cochener B, Cazuguel G. Automatic detection of referral patients due to retinal pathologies through data mining. Med Image Anal 2015; 29:47-64. [PMID: 26774796 DOI: 10.1016/j.media.2015.12.006] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2015] [Revised: 12/17/2015] [Accepted: 12/18/2015] [Indexed: 12/29/2022]
Abstract
With the increased prevalence of retinal pathologies, automating the detection of these pathologies is becoming more and more relevant. In the past few years, many algorithms have been developed for the automated detection of a specific pathology, typically diabetic retinopathy, using eye fundus photography. No matter how good these algorithms are, we believe many clinicians would not use automatic detection tools focusing on a single pathology and ignoring any other pathology present in the patient's retinas. To solve this issue, an algorithm for characterizing the appearance of abnormal retinas, as well as the appearance of the normal ones, is presented. This algorithm does not focus on individual images: it considers examination records consisting of multiple photographs of each retina, together with contextual information about the patient. Specifically, it relies on data mining in order to learn diagnosis rules from characterizations of fundus examination records. The main novelty is that the content of examination records (images and context) is characterized at multiple levels of spatial and lexical granularity: 1) spatial flexibility is ensured by an adaptive decomposition of composite retinal images into a cascade of regions, 2) lexical granularity is ensured by an adaptive decomposition of the feature space into a cascade of visual words. This multigranular representation allows for great flexibility in automatically characterizing normality and abnormality: it is possible to generate diagnosis rules whose precision and generalization ability can be traded off depending on data availability. A variation on usual data mining algorithms, originally designed to mine static data, is proposed so that contextual and visual data at adaptive granularity levels can be mined. This framework was evaluated in e-ophtha, a dataset of 25,702 examination records from the OPHDIAT screening network, as well as in the publicly-available Messidor dataset. It was successfully applied to the detection of patients that should be referred to an ophthalmologist and also to the specific detection of several pathologies.
Collapse
Affiliation(s)
| | - Mathieu Lamard
- Inserm, UMR 1101, SFR ScInBioS, F-29200 Brest, France; Univ Bretagne Occidentale, F-29200 Brest, France
| | - Ali Erginay
- Service d'Ophtalmologie, Hôpital Lariboisière, APHP, F-75475 Paris, France
| | - Agnès Chabouis
- Service d'Ophtalmologie, Hôpital Lariboisière, APHP, F-75475 Paris, France
| | - Pascale Massin
- Service d'Ophtalmologie, Hôpital Lariboisière, APHP, F-75475 Paris, France
| | - Béatrice Cochener
- Inserm, UMR 1101, SFR ScInBioS, F-29200 Brest, France; Univ Bretagne Occidentale, F-29200 Brest, France; Service d'Ophtalmologie, CHRU Brest, F-29200 Brest, France
| | - Guy Cazuguel
- Inserm, UMR 1101, SFR ScInBioS, F-29200 Brest, France; Institut Mines-Telecom; Telecom Bretagne; UEB; Dpt ITI, F-29200 Brest, France
| |
Collapse
|
130
|
Quellec G, Abrámoff MD. Estimating maximal measurable performance for automated decision systems from the characteristics of the reference standard. application to diabetic retinopathy screening. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2014:154-7. [PMID: 25569920 DOI: 10.1109/embc.2014.6943552] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
We investigate the maximal performance that can be measured for automated binary decision systems in terms of area under the ROC curve (AUC), against a reference standard provided by human readers. The goal is to determine the required characteristics of the reference standard to assess and compare automated decision systems with a given degree of confidence, or, to determine what degree of confidence can be obtained given the characteristics of the reference standard. We modeled the expected value of the AUC that can be measured for a perfect decision system, given a reference standard provided either by a single human reader or by multiple human readers (consensus, majority vote). The proposed model was applied to diabetic retinopathy screening in a dataset of 874 eye fundus examinations graded by three readers. The expected value of the AUC for a perfect decision system was estimated at 0.956 against a single human reader, and 0.990 against a `majority wins' vote of three human readers. The Iowa detection program has reached the maximal performance measurable by a single human reader (0.929, CI: [0.897-0.962]) and is close to the maximal performance measurable by a `majority wins' vote (0.955, CI: [0.939-0.972]).
Collapse
|
131
|
Menze BH, Jakab A, Bauer S, Kalpathy-Cramer J, Farahani K, Kirby J, Burren Y, Porz N, Slotboom J, Wiest R, Lanczi L, Gerstner E, Weber MA, Arbel T, Avants BB, Ayache N, Buendia P, Collins DL, Cordier N, Corso JJ, Criminisi A, Das T, Delingette H, Demiralp Ç, Durst CR, Dojat M, Doyle S, Festa J, Forbes F, Geremia E, Glocker B, Golland P, Guo X, Hamamci A, Iftekharuddin KM, Jena R, John NM, Konukoglu E, Lashkari D, Mariz JA, Meier R, Pereira S, Precup D, Price SJ, Raviv TR, Reza SMS, Ryan M, Sarikaya D, Schwartz L, Shin HC, Shotton J, Silva CA, Sousa N, Subbanna NK, Szekely G, Taylor TJ, Thomas OM, Tustison NJ, Unal G, Vasseur F, Wintermark M, Ye DH, Zhao L, Zhao B, Zikic D, Prastawa M, Reyes M, Van Leemput K. The Multimodal Brain Tumor Image Segmentation Benchmark (BRATS). IEEE TRANSACTIONS ON MEDICAL IMAGING 2015; 34:1993-2024. [PMID: 25494501 PMCID: PMC4833122 DOI: 10.1109/tmi.2014.2377694] [Citation(s) in RCA: 1927] [Impact Index Per Article: 192.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
In this paper we report the set-up and results of the Multimodal Brain Tumor Image Segmentation Benchmark (BRATS) organized in conjunction with the MICCAI 2012 and 2013 conferences. Twenty state-of-the-art tumor segmentation algorithms were applied to a set of 65 multi-contrast MR scans of low- and high-grade glioma patients-manually annotated by up to four raters-and to 65 comparable scans generated using tumor image simulation software. Quantitative evaluations revealed considerable disagreement between the human raters in segmenting various tumor sub-regions (Dice scores in the range 74%-85%), illustrating the difficulty of this task. We found that different algorithms worked best for different sub-regions (reaching performance comparable to human inter-rater variability), but that no single algorithm ranked in the top for all sub-regions simultaneously. Fusing several good algorithms using a hierarchical majority vote yielded segmentations that consistently ranked above all individual algorithms, indicating remaining opportunities for further methodological improvements. The BRATS image data and manual annotations continue to be publicly available through an online evaluation system as an ongoing benchmarking resource.
Collapse
|
132
|
Quellec G, Lamard M, Cochener B, Decencière E, Lay B, Chabouis A, Roux C, Cazuguel G. Multimedia data mining for automatic diabetic retinopathy screening. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2013:7144-7. [PMID: 24111392 DOI: 10.1109/embc.2013.6611205] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
This paper presents TeleOphta, an automatic system for screening diabetic retinopathy in teleophthalmology networks. Its goal is to reduce the burden on ophthalmologists by automatically detecting non referable examination records, i.e. examination records presenting no image quality problems and no pathological signs related to diabetic retinopathy or any other retinal pathology. TeleOphta is an attempt to put into practice years of algorithmic developments from our groups. It combines image quality metrics, specific lesion detectors and a generic pathological pattern miner to process the visual content of eye fundus photographs. This visual information is further combined with contextual data in order to compute an abnormality risk for each examination record. The TeleOphta system was trained and tested on a large dataset of 25,702 examination records from the OPHDIAT screening network in Paris. It was able to automatically detect 68% of the non referable examination records while achieving the same sensitivity as a second ophthalmologist. This suggests that it could safely reduce the burden on ophthalmologists by 56%.
Collapse
|
133
|
Inoue T, Hatanaka Y, Okumura S, Muramatsu C, Fujita H. Automated microaneurysm detection method based on Eigenvalue analysis using Hessian matrix in retinal fundus images. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2013:5873-6. [PMID: 24111075 DOI: 10.1109/embc.2013.6610888] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Diabetic retinopathy (DR) is the most frequent cause of blindness. Microaneurysm (MA) is an early symptom of DR. Therefore, the detection of MA is important for the early detection of DR. We have proposed an automated MA detection method based on double-ring filter, but it has given many false positives. In this paper, we propose an MA detection method based on eigenvalue analysis using a Hessian matrix, with an aim to improve MA detection. After image preprocessing, the MA candidate regions were detected by eigenvalue analysis using the Hessian matrix in green-channeled retinal fundus images. Then, 126 features were calculated for each candidate region. By a threshold operation based on feature analysis, false positive candidates were removed. The candidate regions were then classified either as MA or false positive using artificial neural networks (ANN) based on principal component analysis (PCA). The 126 features were reduced to 25 components by PCA, and were then inputted to ANN. When the method was evaluated on visible MAs using 25 retinal images from the retinopathy online challenge (ROC) database, the true positive rate was 73%, with eight false positives per image.
Collapse
|
134
|
Srivastava R, Wong DWK. Red lesion detection in retinal fundus images using Frangi-based filters. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2015:5663-5666. [PMID: 26737577 DOI: 10.1109/embc.2015.7319677] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
This paper presents a method to detect red lesions related to Diabetic Retinopathy (DR), namely Microaneurysms and Hemorrhages from retinal fundus images with robustness to the presence of blood vessels. Filters based on Frangi filters are used for the first time for this task. Green channel of the input image was decomposed into smaller sub images and proposed filters were applied to each sub image after initial preprocessing. Features were extracted from the filter response and used to train a Support Vector Machine classifier to predict whether a test image had lesions or not. Experiments were performed on a dataset of 143 retinal fundus and the proposed method achieved areas under the ROC curve equal to 0.97 and 0.87 for Microaneurysms and Hemorrhages respectively. Results show the effectiveness of the proposed method for detecting red lesions. This method can help significantly in automated detection of DR with fewer false positives.
Collapse
|
135
|
Dutta MK, Parthasarathi M, Ganguly S, Ganguly S, Srivastava K. An efficient image processing based technique for comprehensive detection and grading of nonproliferative diabetic retinopathy from fundus images. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING: IMAGING & VISUALIZATION 2015. [DOI: 10.1080/21681163.2015.1051187] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
136
|
Rahim SS, Jayne C, Palade V, Shuttleworth J. Automatic detection of microaneurysms in colour fundus images for diabetic retinopathy screening. Neural Comput Appl 2015. [DOI: 10.1007/s00521-015-1929-5] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
137
|
Guo L, Yang JJ, Peng L, Li J, Liang Q. A computer-aided healthcare system for cataract classification and grading based on fundus image analysis. COMPUT IND 2015. [DOI: 10.1016/j.compind.2014.09.005] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
138
|
Kapetanakis VV, Rudnicka AR, Liew G, Owen CG, Lee A, Louw V, Bolter L, Anderson J, Egan C, Salas-Vega S, Rudisill C, Taylor P, Tufail A. A study of whether automated Diabetic Retinopathy Image Assessment could replace manual grading steps in the English National Screening Programme. J Med Screen 2015; 22:112-8. [PMID: 25742804 DOI: 10.1177/0969141315571953] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2014] [Accepted: 01/19/2015] [Indexed: 11/17/2022]
Abstract
OBJECTIVES Diabetic retinopathy screening in England involves labour intensive manual grading of digital retinal images. We present the plan for an observational retrospective study of whether automated systems could replace one or more steps of human grading. METHODS Patients aged 12 or older who attended the Diabetes Eye Screening programme, Homerton University Hospital (London) between 1 June 2012 and 4 November 2013 had macular and disc-centred retinal images taken. All screening episodes were manually graded and will additionally be graded by three automated systems. Each system will process all screening episodes, and screening performance (sensitivity, false positive rate, likelihood ratios) and diagnostic accuracy (95% confidence intervals of screening performance measures) will be quantified. A sub-set of gradings will be validated by an approved Reading Centre. Additional analyses will explore the effect of altering thresholds for disease detection within each automated system on screening performance. RESULTS 2,782/20,258 diabetes patients were referred to ophthalmologists for further examination. Prevalence of maculopathy (M1), pre-proliferative retinopathy (R2), and proliferative retinopathy (R3) were 7.9%, 3.1% and 1.2%, respectively; 4749 (23%) patients were diagnosed with background retinopathy (R1); 1.5% were considered ungradable by human graders. CONCLUSIONS Retinopathy prevalence was similar to other English diabetic screening programmes, so findings should be generalizable. The study population size will allow the detection of differences in screening performance between the human and automated grading systems as small as 2%. The project will compare performance and economic costs of manual versus automated systems.
Collapse
Affiliation(s)
- Venediktos V Kapetanakis
- Population Health Research Institute, St George's, University of London, Cranmer Terrace, London, SW17 0RE, United Kingdom
| | - Alicja R Rudnicka
- Population Health Research Institute, St George's, University of London, Cranmer Terrace, London, SW17 0RE, United Kingdom
| | - Gerald Liew
- Centre for Vision Research, University of Sydney, NSW 2006, Australia
| | - Christopher G Owen
- Population Health Research Institute, St George's, University of London, Cranmer Terrace, London, SW17 0RE, United Kingdom
| | - Aaron Lee
- Moorfields BRC, Moorfields Eye Hospital, London, EC1V 2PD, United Kingdom
| | - Vern Louw
- Moorfields BRC, Moorfields Eye Hospital, London, EC1V 2PD, United Kingdom
| | - Louis Bolter
- Homerton University Hospital, Homerton Row, E9 6SR
| | | | - Catherine Egan
- Moorfields BRC, Moorfields Eye Hospital, London, EC1V 2PD, United Kingdom
| | - Sebastian Salas-Vega
- Department of Social Policy, LSE Health, London School of Economics and Political Science, London, WC2A 2AE, United Kingdom
| | - Caroline Rudisill
- Department of Social Policy, LSE Health, London School of Economics and Political Science, London, WC2A 2AE, United Kingdom
| | - Paul Taylor
- CHIME, Institute of Health Informatics, University College London, London, NW1 2HE, United Kingdom
| | - Adnan Tufail
- Moorfields BRC, Moorfields Eye Hospital, London, EC1V 2PD, United Kingdom
| |
Collapse
|
139
|
Torok Z, Peto T, Csosz E, Tukacs E, Molnar AM, Berta A, Tozser J, Hajdu A, Nagy V, Domokos B, Csutak A. Combined Methods for Diabetic Retinopathy Screening, Using Retina Photographs and Tear Fluid Proteomics Biomarkers. J Diabetes Res 2015; 2015:623619. [PMID: 26221613 PMCID: PMC4499636 DOI: 10.1155/2015/623619] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023] Open
Abstract
Background. It is estimated that 347 million people suffer from diabetes mellitus (DM), and almost 5 million are blind due to diabetic retinopathy (DR). The progression of DR can be slowed down with early diagnosis and treatment. Therefore our aim was to develop a novel automated method for DR screening. Methods. 52 patients with diabetes mellitus were enrolled into the project. Of all patients, 39 had signs of DR. Digital retina images and tear fluid samples were taken from each eye. The results from the tear fluid proteomics analysis and from digital microaneurysm (MA) detection on fundus images were used as the input of a machine learning system. Results. MA detection method alone resulted in 0.84 sensitivity and 0.81 specificity. Using the proteomics data for analysis 0.87 sensitivity and 0.68 specificity values were achieved. The combined data analysis integrated the features of the proteomics data along with the number of detected MAs in the associated image and achieved sensitivity/specificity values of 0.93/0.78. Conclusions. As the two different types of data represent independent and complementary information on the outcome, the combined model resulted in a reliable screening method that is comparable to the requirements of DR screening programs applied in clinical routine.
Collapse
Affiliation(s)
- Zsolt Torok
- Department of Computer Graphics and Image Processing, Bioinformatics Research Group, Faculty of Informatics, University of Debrecen, Egyetem tér 1, Debrecen 4032, Hungary
- Department of Ophthalmology, Faculty of Medicine, University of Debrecen, Egyetem tér 1, Debrecen 4032, Hungary
- Astridbio Technologies Inc., 439 University Avenue, Toronto, ON, Canada M5G 1Y8
- *Zsolt Torok:
| | - Tunde Peto
- NIHR Biomedical Research Centre, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, 162 City Road, London EC1V 2PD, UK
| | - Eva Csosz
- Department of Biochemistry and Molecular Biology, Proteomics Core Facility, Faculty of Medicine, University of Debrecen, Egyetem tér 1, Debrecen 4032, Hungary
| | - Edit Tukacs
- Department of Computer Graphics and Image Processing, Bioinformatics Research Group, Faculty of Informatics, University of Debrecen, Egyetem tér 1, Debrecen 4032, Hungary
- Astridbio Technologies Inc., 439 University Avenue, Toronto, ON, Canada M5G 1Y8
| | - Agnes M. Molnar
- Centre for Research on Inner City Health, Keenan Research Centre, Li Ka Shing Knowledge Institute, St Michael's Hospital, 30 Bond Street, Toronto, ON, Canada M5B 1W8
| | - Andras Berta
- Department of Ophthalmology, Faculty of Medicine, University of Debrecen, Egyetem tér 1, Debrecen 4032, Hungary
- InnoTears Ltd., Szent Anna Utca 37/1. 2. em. 1, Debrecen 4024, Hungary
| | - Jozsef Tozser
- Department of Biochemistry and Molecular Biology, Proteomics Core Facility, Faculty of Medicine, University of Debrecen, Egyetem tér 1, Debrecen 4032, Hungary
- InnoTears Ltd., Szent Anna Utca 37/1. 2. em. 1, Debrecen 4024, Hungary
| | - Andras Hajdu
- Department of Computer Graphics and Image Processing, Bioinformatics Research Group, Faculty of Informatics, University of Debrecen, Egyetem tér 1, Debrecen 4032, Hungary
| | - Valeria Nagy
- Department of Ophthalmology, Faculty of Medicine, University of Debrecen, Egyetem tér 1, Debrecen 4032, Hungary
| | - Balint Domokos
- Astridbio Technologies Inc., 439 University Avenue, Toronto, ON, Canada M5G 1Y8
| | - Adrienne Csutak
- Department of Ophthalmology, Faculty of Medicine, University of Debrecen, Egyetem tér 1, Debrecen 4032, Hungary
- InnoTears Ltd., Szent Anna Utca 37/1. 2. em. 1, Debrecen 4024, Hungary
| |
Collapse
|
140
|
Rahim SS, Palade V, Shuttleworth J, Jayne C, Omar RNR. Automatic Detection of Microaneurysms for Diabetic Retinopathy Screening Using Fuzzy Image Processing. ENGINEERING APPLICATIONS OF NEURAL NETWORKS 2015. [DOI: 10.1007/978-3-319-23983-5_7] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
141
|
Zhang Z, Srivastava R, Liu H, Chen X, Duan L, Kee Wong DW, Kwoh CK, Wong TY, Liu J. A survey on computer aided diagnosis for ocular diseases. BMC Med Inform Decis Mak 2014; 14:80. [PMID: 25175552 PMCID: PMC4163681 DOI: 10.1186/1472-6947-14-80] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2013] [Accepted: 08/12/2014] [Indexed: 12/12/2022] Open
Abstract
Background Computer Aided Diagnosis (CAD), which can automate the detection process for ocular diseases, has attracted extensive attention from clinicians and researchers alike. It not only alleviates the burden on the clinicians by providing objective opinion with valuable insights, but also offers early detection and easy access for patients. Method We review ocular CAD methodologies for various data types. For each data type, we investigate the databases and the algorithms to detect different ocular diseases. Their advantages and shortcomings are analyzed and discussed. Result We have studied three types of data (i.e., clinical, genetic and imaging) that have been commonly used in existing methods for CAD. The recent developments in methods used in CAD of ocular diseases (such as Diabetic Retinopathy, Glaucoma, Age-related Macular Degeneration and Pathological Myopia) are investigated and summarized comprehensively. Conclusion While CAD for ocular diseases has shown considerable progress over the past years, the clinical importance of fully automatic CAD systems which are able to embed clinical knowledge and integrate heterogeneous data sources still show great potential for future breakthrough.
Collapse
Affiliation(s)
- Zhuo Zhang
- Institute for Infocomm Research, 1 Fusionopolis Way, Singapore, Singapore.
| | | | | | | | | | | | | | | | | |
Collapse
|
142
|
Zhang B, Kumar BVKV, Zhang D. Detecting diabetes mellitus and nonproliferative diabetic retinopathy using tongue color, texture, and geometry features. IEEE Trans Biomed Eng 2014; 61:491-501. [PMID: 24058014 DOI: 10.1109/tbme.2013.2282625] [Citation(s) in RCA: 66] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Diabetes mellitus (DM) and its complications leading to diabetic retinopathy (DR) are soon to become one of the 21st century's major health problems. This represents a huge financial burden to healthcare officials and governments. To combat this approaching epidemic, this paper proposes a noninvasive method to detect DM and nonproliferative diabetic retinopathy (NPDR), the initial stage of DR based on three groups of features extracted from tongue images. They include color, texture, and geometry. A noninvasive capture device with image correction first captures the tongue images. A tongue color gamut is established with 12 colors representing the tongue color features. The texture values of eight blocks strategically located on the tongue surface, with the additional mean of all eight blocks are used to characterize the nine tongue texture features. Finally, 13 features extracted from tongue images based on measurements, distances, areas, and their ratios represent the geometry features. Applying a combination of the 34 features, the proposed method can separate Healthy/DM tongues as well as NPDR/DM-sans NPDR (DM samples without NPDR) tongues using features from each of the three groups with average accuracies of 80.52% and 80.33%, respectively. This is on a database consisting of 130 Healthy and 296 DM samples, where 29 of those in DM are NPDR.
Collapse
|
143
|
MacGillivray TJ, Trucco E, Cameron JR, Dhillon B, Houston JG, van Beek EJR. Retinal imaging as a source of biomarkers for diagnosis, characterization and prognosis of chronic illness or long-term conditions. Br J Radiol 2014; 87:20130832. [PMID: 24936979 PMCID: PMC4112401 DOI: 10.1259/bjr.20130832] [Citation(s) in RCA: 75] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2013] [Revised: 05/09/2014] [Accepted: 06/16/2014] [Indexed: 11/05/2022] Open
Abstract
The black void behind the pupil was optically impenetrable before the invention of the ophthalmoscope by von Helmholtz over 150 years ago. Advances in retinal imaging and image processing, especially over the past decade, have opened a route to another unexplored landscape, the retinal neurovascular architecture and the retinal ganglion pathways linking to the central nervous system beyond. Exploiting these research opportunities requires multidisciplinary teams to explore the interface sitting at the border between ophthalmology, neurology and computing science. It is from the detail and depth of retinal phenotyping that novel metrics and candidate biomarkers are likely to emerge. Confirmation that in vivo retinal neurovascular measures are predictive of microvascular change in the brain and other organs is likely to be a major area of research activity over the next decade. Unlocking this hidden potential within the retina requires integration of structural and functional data sets, that is, multimodal mapping and longitudinal studies spanning the natural history of the disease process. And with further advances in imaging, it is likely that this area of retinal research will remain active and clinically relevant for many years to come. Accordingly, this review looks at state-of-the-art retinal imaging and its application to diagnosis, characterization and prognosis of chronic illness or long-term conditions.
Collapse
Affiliation(s)
- T J MacGillivray
- Vampire Project, Clinical Research Imaging Centre, University of Edinburgh, Edinburgh, UK
| | | | | | | | | | | |
Collapse
|
144
|
Adal KM, Sidibé D, Ali S, Chaum E, Karnowski TP, Mériaudeau F. Automated detection of microaneurysms using scale-adapted blob analysis and semi-supervised learning. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2014; 114:1-10. [PMID: 24529636 DOI: 10.1016/j.cmpb.2013.12.009] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2013] [Revised: 12/17/2013] [Accepted: 12/17/2013] [Indexed: 06/03/2023]
Abstract
Despite several attempts, automated detection of microaneurysm (MA) from digital fundus images still remains to be an open issue. This is due to the subtle nature of MAs against the surrounding tissues. In this paper, the microaneurysm detection problem is modeled as finding interest regions or blobs from an image and an automatic local-scale selection technique is presented. Several scale-adapted region descriptors are introduced to characterize these blob regions. A semi-supervised based learning approach, which requires few manually annotated learning examples, is also proposed to train a classifier which can detect true MAs. The developed system is built using only few manually labeled and a large number of unlabeled retinal color fundus images. The performance of the overall system is evaluated on Retinopathy Online Challenge (ROC) competition database. A competition performance measure (CPM) of 0.364 shows the competitiveness of the proposed system against state-of-the art techniques as well as the applicability of the proposed features to analyze fundus images.
Collapse
Affiliation(s)
- Kedir M Adal
- Université de Bourgogne, Laboratoire Le2i UMR CNRS 6306, Le Creusot 71200, France.
| | - Désiré Sidibé
- Université de Bourgogne, Laboratoire Le2i UMR CNRS 6306, Le Creusot 71200, France
| | - Sharib Ali
- Université de Bourgogne, Laboratoire Le2i UMR CNRS 6306, Le Creusot 71200, France
| | - Edward Chaum
- Hamilton Eye Institute, U. Tennessee Health Sciences Center, Memphis, TN, USA
| | | | - Fabrice Mériaudeau
- Université de Bourgogne, Laboratoire Le2i UMR CNRS 6306, Le Creusot 71200, France
| |
Collapse
|
145
|
Pereira C, Veiga D, Mahdjoub J, Guessoum Z, Gonçalves L, Ferreira M, Monteiro J. Using a multi-agent system approach for microaneurysm detection in fundus images. Artif Intell Med 2014; 60:179-88. [DOI: 10.1016/j.artmed.2013.12.005] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2013] [Revised: 11/15/2013] [Accepted: 12/22/2013] [Indexed: 11/25/2022]
|
146
|
Usman Akram M, Khalid S, Tariq A, Khan SA, Azam F. Detection and classification of retinal lesions for grading of diabetic retinopathy. Comput Biol Med 2014; 45:161-71. [DOI: 10.1016/j.compbiomed.2013.11.014] [Citation(s) in RCA: 102] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2013] [Revised: 11/11/2013] [Accepted: 11/18/2013] [Indexed: 10/25/2022]
|
147
|
Bria A, Karssemeijer N, Tortorella F. Learning from unbalanced data: A cascade-based approach for detecting clustered microcalcifications. Med Image Anal 2014; 18:241-52. [DOI: 10.1016/j.media.2013.10.014] [Citation(s) in RCA: 57] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2013] [Revised: 10/18/2013] [Accepted: 10/31/2013] [Indexed: 11/29/2022]
|
148
|
Litjens G, Toth R, van de Ven W, Hoeks C, Kerkstra S, van Ginneken B, Vincent G, Guillard G, Birbeck N, Zhang J, Strand R, Malmberg F, Ou Y, Davatzikos C, Kirschner M, Jung F, Yuan J, Qiu W, Gao Q, Edwards PE, Maan B, van der Heijden F, Ghose S, Mitra J, Dowling J, Barratt D, Huisman H, Madabhushi A. Evaluation of prostate segmentation algorithms for MRI: the PROMISE12 challenge. Med Image Anal 2013; 18:359-73. [PMID: 24418598 DOI: 10.1016/j.media.2013.12.002] [Citation(s) in RCA: 315] [Impact Index Per Article: 26.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2013] [Revised: 12/03/2013] [Accepted: 12/05/2013] [Indexed: 10/25/2022]
Abstract
Prostate MRI image segmentation has been an area of intense research due to the increased use of MRI as a modality for the clinical workup of prostate cancer. Segmentation is useful for various tasks, e.g. to accurately localize prostate boundaries for radiotherapy or to initialize multi-modal registration algorithms. In the past, it has been difficult for research groups to evaluate prostate segmentation algorithms on multi-center, multi-vendor and multi-protocol data. Especially because we are dealing with MR images, image appearance, resolution and the presence of artifacts are affected by differences in scanners and/or protocols, which in turn can have a large influence on algorithm accuracy. The Prostate MR Image Segmentation (PROMISE12) challenge was setup to allow a fair and meaningful comparison of segmentation methods on the basis of performance and robustness. In this work we will discuss the initial results of the online PROMISE12 challenge, and the results obtained in the live challenge workshop hosted by the MICCAI2012 conference. In the challenge, 100 prostate MR cases from 4 different centers were included, with differences in scanner manufacturer, field strength and protocol. A total of 11 teams from academic research groups and industry participated. Algorithms showed a wide variety in methods and implementation, including active appearance models, atlas registration and level sets. Evaluation was performed using boundary and volume based metrics which were combined into a single score relating the metrics to human expert performance. The winners of the challenge where the algorithms by teams Imorphics and ScrAutoProstate, with scores of 85.72 and 84.29 overall. Both algorithms where significantly better than all other algorithms in the challenge (p<0.05) and had an efficient implementation with a run time of 8min and 3s per case respectively. Overall, active appearance model based approaches seemed to outperform other approaches like multi-atlas registration, both on accuracy and computation time. Although average algorithm performance was good to excellent and the Imorphics algorithm outperformed the second observer on average, we showed that algorithm combination might lead to further improvement, indicating that optimal performance for prostate segmentation is not yet obtained. All results are available online at http://promise12.grand-challenge.org/.
Collapse
Affiliation(s)
- Geert Litjens
- Radboud University Nijmegen Medical Centre, The Netherlands.
| | | | | | - Caroline Hoeks
- Radboud University Nijmegen Medical Centre, The Netherlands
| | | | | | | | | | | | | | | | | | | | | | | | | | | | - Wu Qiu
- Robarts Research Institute, Canada
| | - Qinquan Gao
- Imperial College London, England, United Kingdom
| | | | | | | | - Soumya Ghose
- Commonwealth Scientific and Industrial Research Organisation, Australia; Université de Bourgogne, France; Universitat de Girona, Spain
| | - Jhimli Mitra
- Commonwealth Scientific and Industrial Research Organisation, Australia; Université de Bourgogne, France; Universitat de Girona, Spain
| | - Jason Dowling
- Commonwealth Scientific and Industrial Research Organisation, Australia
| | - Dean Barratt
- University College London, England, United Kingdom
| | | | | |
Collapse
|
149
|
Mookiah MRK, Acharya UR, Chua CK, Lim CM, Ng EYK, Laude A. Computer-aided diagnosis of diabetic retinopathy: a review. Comput Biol Med 2013; 43:2136-55. [PMID: 24290931 DOI: 10.1016/j.compbiomed.2013.10.007] [Citation(s) in RCA: 168] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2013] [Revised: 09/27/2013] [Accepted: 10/04/2013] [Indexed: 11/29/2022]
Abstract
Diabetes mellitus may cause alterations in the retinal microvasculature leading to diabetic retinopathy. Unchecked, advanced diabetic retinopathy may lead to blindness. It can be tedious and time consuming to decipher subtle morphological changes in optic disk, microaneurysms, hemorrhage, blood vessels, macula, and exudates through manual inspection of fundus images. A computer aided diagnosis system can significantly reduce the burden on the ophthalmologists and may alleviate the inter and intra observer variability. This review discusses the available methods of various retinal feature extractions and automated analysis.
Collapse
|
150
|
Trucco E, Ruggeri A. Towards a multi-site international public dataset for the validation of retinal image analysis software. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2013; 2013:7152-5. [PMID: 24111394 DOI: 10.1109/embc.2013.6611207] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
This paper discusses concisely the main issues and challenges posed by the validation of retinal image analysis algorithms. It is designed to set the discussion for the IEEE EBMC 2013 invited session "From laboratory to clinic: the validation of retinal image processing tools ". The session carries forward an international initiative started at EMBC 2011, Boston, which resulted in the first large-consensus paper (14 international sites) on the validation of retinal image processing software, appearing in IOVS. This paper is meant as a focus for the session discussion, but the ubiquity and importance of validation makes its contents, arguably, of interest for the wider medical image processing community.
Collapse
|