151
|
Standardized evaluation methodology and reference database for evaluating IVUS image segmentation. Comput Med Imaging Graph 2013; 38:70-90. [PMID: 24012215 DOI: 10.1016/j.compmedimag.2013.07.001] [Citation(s) in RCA: 86] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2012] [Revised: 03/15/2013] [Accepted: 07/01/2013] [Indexed: 11/21/2022]
Abstract
This paper describes an evaluation framework that allows a standardized and quantitative comparison of IVUS lumen and media segmentation algorithms. This framework has been introduced at the MICCAI 2011 Computing and Visualization for (Intra)Vascular Imaging (CVII) workshop, comparing the results of eight teams that participated. We describe the available data-base comprising of multi-center, multi-vendor and multi-frequency IVUS datasets, their acquisition, the creation of the reference standard and the evaluation measures. The approaches address segmentation of the lumen, the media, or both borders; semi- or fully-automatic operation; and 2-D vs. 3-D methodology. Three performance measures for quantitative analysis have been proposed. The results of the evaluation indicate that segmentation of the vessel lumen and media is possible with an accuracy that is comparable to manual annotation when semi-automatic methods are used, as well as encouraging results can be obtained also in case of fully-automatic segmentation. The analysis performed in this paper also highlights the challenges in IVUS segmentation that remains to be solved.
Collapse
|
152
|
Torok Z, Peto T, Csosz E, Tukacs E, Molnar A, Maros-Szabo Z, Berta A, Tozser J, Hajdu A, Nagy V, Domokos B, Csutak A. Tear fluid proteomics multimarkers for diabetic retinopathy screening. BMC Ophthalmol 2013; 13:40. [PMID: 23919537 PMCID: PMC3770351 DOI: 10.1186/1471-2415-13-40] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2013] [Accepted: 07/31/2013] [Indexed: 12/17/2022] Open
Abstract
Background The aim of the project was to develop a novel method for diabetic retinopathy screening based on the examination of tear fluid biomarker changes. In order to evaluate the usability of protein biomarkers for pre-screening purposes several different approaches were used, including machine learning algorithms. Methods All persons involved in the study had diabetes. Diabetic retinopathy (DR) was diagnosed by capturing 7-field fundus images, evaluated by two independent ophthalmologists. 165 eyes were examined (from 119 patients), 55 were diagnosed healthy and 110 images showed signs of DR. Tear samples were taken from all eyes and state-of-the-art nano-HPLC coupled ESI-MS/MS mass spectrometry protein identification was performed on all samples. Applicability of protein biomarkers was evaluated by six different optimally parameterized machine learning algorithms: Support Vector Machine, Recursive Partitioning, Random Forest, Naive Bayes, Logistic Regression, K-Nearest Neighbor. Results Out of the six investigated machine learning algorithms the result of Recursive Partitioning proved to be the most accurate. The performance of the system realizing the above algorithm reached 74% sensitivity and 48% specificity. Conclusions Protein biomarkers selected and classified with machine learning algorithms alone are at present not recommended for screening purposes because of low specificity and sensitivity values. This tool can be potentially used to improve the results of image processing methods as a complementary tool in automatic or semiautomatic systems.
Collapse
Affiliation(s)
- Zsolt Torok
- Department of Computer Graphics and Image Processing, University of Debrecen, Faculty of Informatics, Debrecen, Hungary.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
153
|
Li B, Li HK. Automated analysis of diabetic retinopathy images: principles, recent developments, and emerging trends. Curr Diab Rep 2013; 13:453-9. [PMID: 23686810 DOI: 10.1007/s11892-013-0393-9] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
Diabetic retinopathy (DR) is a vision-threatening complication of diabetes. Timely diagnosis and intervention are essential for treatment that reduces the risk of vision loss. A good color retinal (fundus) photograph can be used as a surrogate for face-to-face evaluation of DR. The use of computers to assist or fully automate DR evaluation from retinal images has been studied for many years. Early work showed promising results for algorithms in detecting and classifying DR pathology. Newer techniques include those that adapt machine learning technology to DR image analysis. Challenges remain, however, that must be overcome before fully automatic DR detection and analysis systems become practical clinical tools.
Collapse
Affiliation(s)
- Baoxin Li
- School of Computing, Informatics & Decision Systems Engineering, Arizona State University, Tempe, AZ 85281, USA.
| | | |
Collapse
|
154
|
Antal B, Lázár I, Hajdu A. An adaptive weighting approach for ensemble-based detection of microaneurysms in color fundus images. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2013; 2012:5955-8. [PMID: 23367285 DOI: 10.1109/embc.2012.6347350] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
In this paper, we present an adaptive weighting approach to microaneurysm detector ensembles. The basis of the adaptive weighting approach is the spatial location and contrast of the detected microaneurysm. During training, the performance of ensemble members is measured with a respect to these contextual information, which serves as a basis for the optimal weights assigned to detectors. We have tested this approach on two publicly available datasets, where it showed its competitiveness compared with out previously published ensemble-based approach for microaneurysm detection. Moreover, the proposed approach outperformed all the investigated individual detectors.
Collapse
Affiliation(s)
- Bálint Antal
- Faculty of Informatics, University of Debrecen, 4010 Debrecen, POB 12, Hungary.
| | | | | |
Collapse
|
155
|
Improving microaneurysm detection in color fundus images by using context-aware approaches. Comput Med Imaging Graph 2013; 37:403-8. [DOI: 10.1016/j.compmedimag.2013.05.001] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2012] [Revised: 05/05/2013] [Accepted: 05/06/2013] [Indexed: 11/19/2022]
|
156
|
Setiawan AW, Suksmono AB, Mengko TR, Santoso OS. Performance Evaluation of Color Retinal Image Quality Assessment in Asymmetric Channel VQ Coding. INTERNATIONAL JOURNAL OF E-HEALTH AND MEDICAL COMMUNICATIONS 2013. [DOI: 10.4018/jehmc.2013070101] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The RGB color retinal image has an interesting characteristic, i.e. the G channel contains more important information than the other ones. One of the most important features in a retinal image is the retinal blood vessel structure. Many diseases can be diagnosed based on in the retinal blood vessel, such as micro aneurysms that can lead to blindness. In the G channel, the contrast between retinal blood vessel and its background is significantly high. The authors explore this retinal image characteristic to construct a more suitable image coding system. The coding processes are conduct in three schemes: weighted R channel, weighted G channel, and weighted B channel coding. Their hypothesis is that allocating more bits in the G channel will improve the coding performance. The authors seek for image quality assessment (IQA) metrics that can be used to measure the distortion in retinal image coding. Three different metrics, namely Peak Signal to Noise Ratio (PSNR), Structure Similarity (SSIM), and Visual Information Fidelity (VIF) are compared as objective assessment in image coding and to show quantitatively that G channel has more important role compared to the other ones. The authors use Vector Quantization (VQ) as image coding method due to its simplicity and low-complexity than the other methods. Experiments with actual retinal image shows that the minimum value of SSIM and VIF required in this coding scheme is 0.9940 and 0.8637.
Collapse
Affiliation(s)
| | - Andriyan B. Suksmono
- School of Electrical Engineering and Informatics, Institut Teknologi Bandung, Bandung, Indonesia
| | - Tati R. Mengko
- School of Electrical Engineering and Informatics, Institut Teknologi Bandung, Bandung, Indonesia
| | | |
Collapse
|
157
|
Constructing benchmark databases and protocols for medical image analysis: diabetic retinopathy. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2013; 2013:368514. [PMID: 23956787 PMCID: PMC3703800 DOI: 10.1155/2013/368514] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/25/2013] [Accepted: 05/26/2013] [Indexed: 11/17/2022]
Abstract
We address the performance evaluation practices for developing medical image analysis methods, in particular, how to establish and share databases of medical images with verified ground truth and solid evaluation protocols. Such databases support the development of better algorithms, execution of profound method comparisons, and, consequently, technology transfer from research laboratories to clinical practice. For this purpose, we propose a framework consisting of reusable methods and tools for the laborious task of constructing a benchmark database. We provide a software tool for medical image annotation helping to collect class label, spatial span, and expert's confidence on lesions and a method to appropriately combine the manual segmentations from multiple experts. The tool and all necessary functionality for method evaluation are provided as public software packages. As a case study, we utilized the framework and tools to establish the DiaRetDB1 V2.1 database for benchmarking diabetic retinopathy detection algorithms. The database contains a set of retinal images, ground truth based on information from multiple experts, and a baseline algorithm for the detection of retinopathy lesions.
Collapse
|
158
|
Trucco E, Ruggeri A, Karnowski T, Giancardo L, Chaum E, Hubschman JP, Al-Diri B, Cheung CY, Wong D, Abràmoff M, Lim G, Kumar D, Burlina P, Bressler NM, Jelinek HF, Meriaudeau F, Quellec G, Macgillivray T, Dhillon B. Validating retinal fundus image analysis algorithms: issues and a proposal. Invest Ophthalmol Vis Sci 2013; 54:3546-59. [PMID: 23794433 DOI: 10.1167/iovs.12-10347] [Citation(s) in RCA: 119] [Impact Index Per Article: 9.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
This paper concerns the validation of automatic retinal image analysis (ARIA) algorithms. For reasons of space and consistency, we concentrate on the validation of algorithms processing color fundus camera images, currently the largest section of the ARIA literature. We sketch the context (imaging instruments and target tasks) of ARIA validation, summarizing the main image analysis and validation techniques. We then present a list of recommendations focusing on the creation of large repositories of test data created by international consortia, easily accessible via moderated Web sites, including multicenter annotations by multiple experts, specific to clinical tasks, and capable of running submitted software automatically on the data stored, with clear and widely agreed-on performance criteria, to provide a fair comparison.
Collapse
Affiliation(s)
- Emanuele Trucco
- VAMPIRE project, School of Computing, University of Dundee, Dundee, United Kingdom.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
159
|
Quellec G, Lamard M, Cochener B, Droueche Z, Lay B, Chabouis A, Roux C, Cazuguel G. Studying disagreements among retinal experts through image analysis. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2013; 2012:5959-62. [PMID: 23367286 DOI: 10.1109/embc.2012.6347351] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
In recent years, many image analysis algorithms have been presented to assist Diabetic Retinopathy (DR) screening. The goal was usually to detect healthy examination records automatically, in order to reduce the number of records that should be analyzed by retinal experts. In this paper, a novel application is presented: these algorithms are used to 1) discover image characteristics that sometimes cause an expert to disagree with his/her peers and 2) warn the expert whenever these characteristics are detected in an examination record. In a DR screening program, each examination record is only analyzed by one expert, therefore analyzing disagreements among experts is challenging. A statistical framework, based on Parzen-windowing and the Patrick-Fischer distance, is presented to solve this problem. Disagreements among eleven experts from the Ophdiat screening program were analyzed, using an archive of 25,702 examination records.
Collapse
|
160
|
Lazar I, Hajdu A. Retinal microaneurysm detection through local rotating cross-section profile analysis. IEEE TRANSACTIONS ON MEDICAL IMAGING 2013. [PMID: 23192523 DOI: 10.1109/tmi.2012.2228665] [Citation(s) in RCA: 65] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
A method for the automatic detection of microaneurysms (MAs) in color retinal images is proposed in this paper. The recognition of MAs is an essential step in the diagnosis and grading of diabetic retinopathy. The proposed method realizes MA detection through the analysis of directional cross-section profiles centered on the local maximum pixels of the preprocessed image. Peak detection is applied on each profile, and a set of attributes regarding the size, height, and shape of the peak are calculated subsequently. The statistical measures of these attribute values as the orientation of the cross-section changes constitute the feature set that is used in a naïve Bayes classification to exclude spurious candidates. We give a formula for the final score of the remaining candidates, which can be thresholded further for a binary output. The proposed method has been tested in the Retinopathy Online Challenge, where it proved to be competitive with the state-of-the-art approaches. We also present the experimental results for a private image set using the same classifier setup.
Collapse
Affiliation(s)
- Istvan Lazar
- Department of Informatics, University of Debrecen, 4010 Debrecen, Hungary.
| | | |
Collapse
|
161
|
Abràmoff M, Kay CN. Image Processing. Retina 2013. [DOI: 10.1016/b978-1-4557-0737-9.00006-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
162
|
Abstract
PURPOSE To compare diabetic retinopathy (DR) referral recommendations made by viewing fundus images using a tablet computer with those made using a standard desktop display. METHODS A tablet computer (iPad) and a desktop computer with a high-definition color display were compared. For each platform, 2 retinal specialists independently rated 1,200 color fundus images from patients at risk for DR using an annotation program Truthseeker. The specialists determined whether each image had referable DR and also how urgently each patient should be referred for medical examination. Graders viewed and rated the randomly presented images independently and were masked to their ratings on the alternative platform. Tablet-based and desktop display-based referral ratings were compared using cross-platform intraobserver kappa as the primary outcome measure. Additionally, interobserver kappa, sensitivity, specificity, and area under the receiver operating characteristic were determined. RESULTS A high level of cross-platform intraobserver agreement was found for the DR referral ratings between the platforms (κ = 0.778) and for the 2 graders (κ = 0.812). Interobserver agreement was similar for the 2 platforms (κ = 0.544 and κ = 0.625 for tablet and desktop, respectively). The tablet-based ratings achieved a sensitivity of 0.848, a specificity of 0.987, and an area under the receiver operating characteristic of 0.950 compared with desktop display-based ratings. CONCLUSION In this pilot study, tablet-based rating of color fundus images for subjects at risk for DR was consistent with desktop display-based rating. These results indicate that tablet computers can be reliably used for clinical evaluation of fundus images for DR.
Collapse
|
163
|
Jiang X, Lambers M, Bunke H. Structural performance evaluation of curvilinear structure detection algorithms with application to retinal vessel segmentation. Pattern Recognit Lett 2012. [DOI: 10.1016/j.patrec.2012.05.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
164
|
Fraz MM, Remagnino P, Hoppe A, Uyyanonvara B, Rudnicka AR, Owen CG, Barman SA. Blood vessel segmentation methodologies in retinal images--a survey. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2012; 108:407-33. [PMID: 22525589 DOI: 10.1016/j.cmpb.2012.03.009] [Citation(s) in RCA: 337] [Impact Index Per Article: 25.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2011] [Revised: 03/05/2012] [Accepted: 03/24/2012] [Indexed: 05/20/2023]
Abstract
Retinal vessel segmentation algorithms are a fundamental component of automatic retinal disease screening systems. This work examines the blood vessel segmentation methodologies in two dimensional retinal images acquired from a fundus camera and a survey of techniques is presented. The aim of this paper is to review, analyze and categorize the retinal vessel extraction algorithms, techniques and methodologies, giving a brief description, highlighting the key points and the performance measures. We intend to give the reader a framework for the existing research; to introduce the range of retinal vessel segmentation algorithms; to discuss the current trends and future directions and summarize the open problems. The performance of algorithms is compared and analyzed on two publicly available databases (DRIVE and STARE) of retinal images using a number of measures which include accuracy, true positive rate, false positive rate, sensitivity, specificity and area under receiver operating characteristic (ROC) curve.
Collapse
Affiliation(s)
- M M Fraz
- Digital Imaging Research Centre, Faculty of Science, Engineering and Computing, Kingston University London, London, United Kingdom.
| | | | | | | | | | | | | |
Collapse
|
165
|
Zhang B, Karray F, Li Q, Zhang L. Sparse Representation Classifier for microaneurysm detection and retinal blood vessel extraction. Inf Sci (N Y) 2012. [DOI: 10.1016/j.ins.2012.03.003] [Citation(s) in RCA: 67] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
166
|
Kovács G, Hajdu A. Translation Invariance in the Polynomial Kernel Space and Its Applications in kNN Classification. Neural Process Lett 2012. [DOI: 10.1007/s11063-012-9242-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
167
|
Rocha A, Carvalho T, Jelinek HF, Goldenstein S, Wainer J. Points of Interest and Visual Dictionaries for Automatic Retinal Lesion Detection. IEEE Trans Biomed Eng 2012; 59:2244-53. [DOI: 10.1109/tbme.2012.2201717] [Citation(s) in RCA: 90] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
168
|
Köse C, Sevik U, Ikibaş C, Erdöl H. Simple methods for segmentation and measurement of diabetic retinopathy lesions in retinal fundus images. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2012; 107:274-293. [PMID: 21757250 DOI: 10.1016/j.cmpb.2011.06.007] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/07/2010] [Revised: 06/16/2011] [Accepted: 06/17/2011] [Indexed: 05/31/2023]
Abstract
Diabetic retinopathy (DR) is one of the most important complications of diabetes mellitus, which causes serious damages in the retina, consequently visual loss and sometimes blindness if necessary medical treatment is not applied on time. One of the difficulties in this illness is that the patient with diabetes mellitus requires a continuous screening for early detection. So far, numerous methods have been proposed by researchers to automate the detection process of DR in retinal fundus images. In this paper, we developed an alternative simple approach to detect DR. This method was built on the inverse segmentation method, which we suggested before to detect Age Related Macular Degeneration (ARMDs). Background image approach along with inverse segmentation is employed to measure and follow up the degenerations in retinal fundus images. Direct segmentation techniques generate unsatisfactory results in some cases. This is because of the fact that the texture of unhealthy areas such as DR is not homogenous. The inverse method is proposed to exploit the homogeneity of healthy areas rather than dealing with varying structure of unhealthy areas for segmenting bright lesions (hard exudates and cotton wool spots). On the other hand, the background image, dividing the retinal image into high and low intensity areas, is exploited in segmentation of hard exudates and cotton wool spots, and microaneurysms (MAs) and hemorrhages (HEMs), separately. Therefore, a complete segmentation system is developed for segmenting DR, including hard exudates, cotton wool spots, MAs, and HEMs. This application is able to measure total changes across the whole retinal image. Hence, retinal images that belong to the same patients are examined in order to monitor the trend of the illness. To make a comparison with other methods, a Naïve Bayes method is applied for segmentation of DR. The performance of the system, tested on different data sets including various qualities of retinal fundus images, is over 95% in detection of the optic disc (OD), and 90% in segmentation of the DR.
Collapse
Affiliation(s)
- Cemal Köse
- Department of Computer Engineering, Faculty of Engineering, Karadeniz Technical University, 61080 Trabzon, Turkey.
| | | | | | | |
Collapse
|
169
|
A multiple-instance learning framework for diabetic retinopathy screening. Med Image Anal 2012; 16:1228-40. [DOI: 10.1016/j.media.2012.06.003] [Citation(s) in RCA: 65] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2012] [Revised: 04/23/2012] [Accepted: 06/11/2012] [Indexed: 11/21/2022]
|
170
|
Jiménez S, Alemany P, Núñez FJ, Fondón I, Serrano C, Acha B, Failde I. [Automated detection of microaneurysms by using region growing and Fuzzy Artmap neural network]. ACTA ACUST UNITED AC 2012; 87:284-9. [PMID: 22824647 DOI: 10.1016/j.oftal.2012.04.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2012] [Revised: 03/29/2012] [Accepted: 04/08/2012] [Indexed: 10/28/2022]
Abstract
OBJECTIVE To assess whether the methodological changes of this new algorithm improves the results of a previously presented strategy. METHODS We enhance the image and filter out the green channel of the digital color retinography. Multitolerance thresholding was applied to obtain candidate points and make a seed growing region by varying intensities. We took 15 characteristics from each region to train a Fuzzy Artmap neural network using 42 retinal photographs. This network was then applied in the study of 11 good quality retinal photographs included in the diabetic retinopathy early detection screening program, with initial stages of retinopathy, obtained with the Topcon NW200 non-mydriatic retinal camera. RESULTS Two experienced ophthalmologists detected 52 microaneurysms in 11 images. The algorithm detected 39 microaneurysms and 3,752 more regions, confirming 38 microaneurysm and 135 false positives. The sensitivity is improved compared to the previous algorithm, from 60.53 to 73.08%. False positives have dropped from 41.8 to 12.27 per image. CONCLUSIONS The new algorithm is better than the previous one, but there is still room for improvement, especially in the initial determination of seeds.
Collapse
Affiliation(s)
- S Jiménez
- Servicio de Oftalmología, Hospital Universitario Puerta del Mar, Cádiz, España.
| | | | | | | | | | | | | |
Collapse
|
171
|
Detecting optic disc on asians by multiscale gaussian filtering. Int J Biomed Imaging 2012; 2012:727154. [PMID: 22844267 PMCID: PMC3392893 DOI: 10.1155/2012/727154] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2012] [Revised: 04/23/2012] [Accepted: 04/23/2012] [Indexed: 11/18/2022] Open
Abstract
The optic disc (OD) is an important anatomical feature in retinal images, and its detection is vital for developing automated screening programs. Currently, there is no algorithm designed to automatically detect the OD in fundus images captured from Asians which are larger and have thicker vessels compared to Caucasians. In this paper, we propose such a method to complement current algorithms using two steps: OD vessel candidate detection and OD vessel candidate matching. The first step is achieved with multiscale Gaussian filtering, scale production, and double thresholding to initially extract the vessels' directional map of various thicknesses. The map is then thinned before another threshold is applied to remove pixels with low intensities. This result forms the OD vessel candidates. In the second step, a Vessels' Directional Matched Filter (VDMF) of various dimensions is applied to the candidates to be matched, and the pixel with the smallest difference designated the OD center. We tested the proposed method on a new database consisting of 402 images from a diabetic retinopathy (DR) screening programme consisting of Asians. The OD center was successfully detected with an accuracy of 99.25% (399/402).
Collapse
|
172
|
Giancardo L, Meriaudeau F, Karnowski TP, Li Y, Tobin KW, Chaum E. Microaneurysm detection with radon transform-based classification on retina images. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2012; 2011:5939-42. [PMID: 22255692 DOI: 10.1109/iembs.2011.6091562] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The creation of an automatic diabetic retinopathy screening system using retina cameras is currently receiving considerable interest in the medical imaging community. The detection of microaneurysms is a key element in this effort. In this work, we propose a new microaneurysms segmentation technique based on a novel application of the radon transform, which is able to identify these lesions without any previous knowledge of the retina morphological features and with minimal image preprocessing. The algorithm has been evaluated on the Retinopathy Online Challenge public dataset, and its performance compares with the best current techniques. The performance is particularly good at low false positive ratios, which makes it an ideal candidate for diabetic retinopathy screening systems.
Collapse
Affiliation(s)
- L Giancardo
- Oak Ridge National Laboratory, University of Burgundy.
| | | | | | | | | | | |
Collapse
|
173
|
Antal B, Hajdu A. An Ensemble-Based System for Microaneurysm Detection and Diabetic Retinopathy Grading. IEEE Trans Biomed Eng 2012; 59:1720-6. [DOI: 10.1109/tbme.2012.2193126] [Citation(s) in RCA: 210] [Impact Index Per Article: 16.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
174
|
Ensemble Classification System Applied for Retinal Vessel Segmentation on Child Images Containing Various Vessel Profiles. ACTA ACUST UNITED AC 2012. [DOI: 10.1007/978-3-642-31298-4_45] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
|
175
|
Giancardo L, Meriaudeau F, Karnowski TP, Li Y, Garg S, Tobin KW, Chaum E. Exudate-based diabetic macular edema detection in fundus images using publicly available datasets. Med Image Anal 2012; 16:216-26. [PMID: 21865074 PMCID: PMC10729314 DOI: 10.1016/j.media.2011.07.004] [Citation(s) in RCA: 121] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2010] [Revised: 07/11/2011] [Accepted: 07/12/2011] [Indexed: 01/14/2023]
Abstract
Diabetic macular edema (DME) is a common vision threatening complication of diabetic retinopathy. In a large scale screening environment DME can be assessed by detecting exudates (a type of bright lesions) in fundus images. In this work, we introduce a new methodology for diagnosis of DME using a novel set of features based on colour, wavelet decomposition and automatic lesion segmentation. These features are employed to train a classifier able to automatically diagnose DME through the presence of exudation. We present a new publicly available dataset with ground-truth data containing 169 patients from various ethnic groups and levels of DME. This and other two publicly available datasets are employed to evaluate our algorithm. We are able to achieve diagnosis performance comparable to retina experts on the MESSIDOR (an independently labelled dataset with 1200 images) with cross-dataset testing (e.g., the classifier was trained on an independent dataset and tested on MESSIDOR). Our algorithm obtained an AUC between 0.88 and 0.94 depending on the dataset/features used. Additionally, it does not need ground truth at lesion level to reject false positives and is computationally efficient, as it generates a diagnosis on an average of 4.4s (9.3s, considering the optic nerve localisation) per image on an 2.6 GHz platform with an unoptimised Matlab implementation.
Collapse
Affiliation(s)
- Luca Giancardo
- Oak Ridge National Laboratory/University of Burgundy Imaging, Signals, and Machine Learning (ISML), PO Box 2008, MS6075 Oak Ridge, TN 37831-6075, United States.
| | | | | | | | | | | | | |
Collapse
|
176
|
Li HK, Horton M, Bursell SE, Cavallerano J, Zimmer-Galler I, Tennant M, Abramoff M, Chaum E, DeBuc DC, Leonard-Martin T, Winchester M. Telehealth practice recommendations for diabetic retinopathy, second edition. Telemed J E Health 2011; 17:814-37. [PMID: 21970573 PMCID: PMC6469533 DOI: 10.1089/tmj.2011.0075] [Citation(s) in RCA: 89] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2011] [Revised: 04/25/2011] [Accepted: 04/25/2011] [Indexed: 12/18/2022] Open
Abstract
Ocular telemedicine and telehealth have the potential to decrease vision loss from DR. Planning, execution, and follow-up are key factors for success. Telemedicine is complex, requiring the services of expert teams working collaboratively to provide care matching the quality of conventional clinical settings. Improving access and outcomes, however, makes telemedicine a valuable tool for our diabetic patients. Programs that focus on patient needs, consider available resources, define clear goals, promote informed expectations, appropriately train personnel, and adhere to regulatory and statutory requirements have the highest chance of achieving success.
Collapse
Affiliation(s)
- Helen K. Li
- Department of Ophthalmology, Weill Cornell Medical College/The Methodist Hospital, Houston, Texas
- School of Biomedical Informatics, University of Texas Health Science Center, Houston, Texas
- Department of Ophthalmology, Jefferson Medical College, Philadelphia, Pennsylvannia
| | - Mark Horton
- Phoenix Indian Medical Center, Phoenix, Arizona
| | - Sven-Erik Bursell
- Telehealth Research Institute, John A. Burns School of Medicine, Honolulu, Hawaii
| | - Jerry Cavallerano
- Joslin Diabetes Center, Beetham Eye Institute, Boston, Massachusetts
| | | | - Mathew Tennant
- Department of Ophthalmology, University of Alberta, Edmonton, Canada
| | - Michael Abramoff
- Department of Ophthalmology and Visual Sciences, The University of Iowa Hospital and Clinics, Iowa City, Iowa
| | - Edward Chaum
- Hamilton Eye Institute, University of Tennessee Health Science Center, Memphis, Tennessee
| | | | | | | |
Collapse
|
177
|
Quellec G, Abràmoff M, Cazuguel G, Lamard M, Cochener B, Roux C. Fouille d’images multi-instance et multi-résolution appliquée au dépistage de la rétinopathie diabétique. Ing Rech Biomed 2011. [DOI: 10.1016/j.irbm.2011.09.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/15/2022]
|
178
|
Bernardes R, Serranho P, Lobo C. Digital ocular fundus imaging: a review. ACTA ACUST UNITED AC 2011; 226:161-81. [PMID: 21952522 DOI: 10.1159/000329597] [Citation(s) in RCA: 97] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2011] [Accepted: 05/23/2011] [Indexed: 01/09/2023]
Abstract
Ocular fundus imaging plays a key role in monitoring the health status of the human eye. Currently, a large number of imaging modalities allow the assessment and/or quantification of ocular changes from a healthy status. This review focuses on the main digital fundus imaging modality, color fundus photography, with a brief overview of complementary techniques, such as fluorescein angiography. While focusing on two-dimensional color fundus photography, the authors address the evolution from nondigital to digital imaging and its impact on diagnosis. They also compare several studies performed along the transitional path of this technology. Retinal image processing and analysis, automated disease detection and identification of the stage of diabetic retinopathy (DR) are addressed as well. The authors emphasize the problems of image segmentation, focusing on the major landmark structures of the ocular fundus: the vascular network, optic disk and the fovea. Several proposed approaches for the automatic detection of signs of disease onset and progression, such as microaneurysms, are surveyed. A thorough comparison is conducted among different studies with regard to the number of eyes/subjects, imaging modality, fundus camera used, field of view and image resolution to identify the large variation in characteristics from one study to another. Similarly, the main features of the proposed classifications and algorithms for the automatic detection of DR are compared, thereby addressing computer-aided diagnosis and computer-aided detection for use in screening programs.
Collapse
Affiliation(s)
- Rui Bernardes
- Institute of Biomedical Research on Light and Image, Faculty of Medicine, University of Coimbra, and Coimbra University Hospital, Coimbra, Portugal.
| | | | | |
Collapse
|
179
|
Ram K, Joshi GD, Sivaswamy J. A Successive Clutter-Rejection-Based Approach for Early Detection of Diabetic Retinopathy. IEEE Trans Biomed Eng 2011; 58:664-73. [DOI: 10.1109/tbme.2010.2096223] [Citation(s) in RCA: 85] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
180
|
Hameeteman K, Zuluaga MA, Freiman M, Joskowicz L, Cuisenaire O, Valencia LF, Gülsün MA, Krissian K, Mille J, Wong WCK, Orkisz M, Tek H, Hoyos MH, Benmansour F, Chung ACS, Rozie S, van Gils M, van den Borne L, Sosna J, Berman P, Cohen N, Douek PC, Sánchez I, Aissat M, Schaap M, Metz CT, Krestin GP, van der Lugt A, Niessen WJ, van Walsum T. Evaluation framework for carotid bifurcation lumen segmentation and stenosis grading. Med Image Anal 2011; 15:477-88. [PMID: 21419689 DOI: 10.1016/j.media.2011.02.004] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2010] [Revised: 02/04/2011] [Accepted: 02/10/2011] [Indexed: 12/01/2022]
Abstract
This paper describes an evaluation framework that allows a standardized and objective quantitative comparison of carotid artery lumen segmentation and stenosis grading algorithms. We describe the data repository comprising 56 multi-center, multi-vendor CTA datasets, their acquisition, the creation of the reference standard and the evaluation measures. This framework has been introduced at the MICCAI 2009 workshop 3D Segmentation in the Clinic: A Grand Challenge III, and we compare the results of eight teams that participated. These results show that automated segmentation of the vessel lumen is possible with a precision that is comparable to manual annotation. The framework is open for new submissions through the website http://cls2009.bigr.nl.
Collapse
Affiliation(s)
- K Hameeteman
- Biomedical Imaging Group Rotterdam, Departments of Radiology & Medical Informatics, Erasmus MC, P.O. Box 2040, 3000 CA Rotterdam, The Netherlands.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
181
|
Niemeijer M, Loog M, Abramoff MD, Viergever MA, Prokop M, van Ginneken B. On combining computer-aided detection systems. IEEE TRANSACTIONS ON MEDICAL IMAGING 2011; 30:215-223. [PMID: 20813633 DOI: 10.1109/tmi.2010.2072789] [Citation(s) in RCA: 60] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Computer-aided detection (CAD) is increasingly used in clinical practice and for many applications a multitude of CAD systems have been developed. In practice, CAD systems have different strengths and weaknesses and it is therefore interesting to consider their combination. In this paper, we present generic methods to combine multiple CAD systems and investigate what kind of performance increase can be expected. Experimental results are presented using data from the ANODE09 and ROC09 online CAD challenges for the detection of pulmonary nodules in computed tomography scans and red lesions in retinal images, respectively. For both applications, combination results in a large and significant increase in performance when compared to the best individual CAD system.
Collapse
Affiliation(s)
- Meindert Niemeijer
- University Medical Center Utrecht, Image Sciences Institute, 3584 CX Utrecht, The Netherlands.
| | | | | | | | | | | |
Collapse
|
182
|
Quellec G, Russell SR, Abramoff MD. Optimal filter framework for automated, instantaneous detection of lesions in retinal images. IEEE TRANSACTIONS ON MEDICAL IMAGING 2011; 30:523-533. [PMID: 21292586 DOI: 10.1109/tmi.2010.2089383] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Automated detection of lesions in retinal images is a crucial step towards efficient early detection, or screening, of large at-risk populations. In particular, the detection of microaneurysms, usually the first sign of diabetic retinopathy (DR), and the detection of drusen, the hallmark of age-related macular degeneration (AMD), are of primary importance. In spite of substantial progress made, detection algorithms still produce 1) false positives-target lesions are mixed up with other normal or abnormal structures in the eye, and 2) false negatives-the large variability in the appearance of the lesions causes a subset of these target lesions to be missed. We propose a general framework for detecting and characterizing target lesions almost instantaneously. This framework relies on a feature space automatically derived from a set of reference image samples representing target lesions, including atypical target lesions, and those eye structures that are similar looking but are not target lesions. The reference image samples are obtained either from an expert- or a data-driven approach. Factor analysis is used to derive the filters generating this feature space from reference samples. Previously unseen image samples are then classified in this feature space. We tested this approach by training it to detect microaneurysms. On a set of images from 2739 patients including 67 with referable DR, DR detection area under the receiver-operating characteristic curve (AUC) was comparable (AUC=0.927) to our previously published red lesion detection algorithm (AUC=0.929). We also tested the approach on the detection of AMD, by training it to differentiate drusen from Stargardt's disease lesions, and achieved an AUC=0.850 on a set of 300 manually detected drusen and 300 manually detected flecks. The entire image processing sequence takes less than a second on a standard PC compared to minutes in our previous approach, allowing instantaneous detection. Free-response receiver-operating characteristic analysis showed the superiority of this approach over a framework where false positives and the atypical lesions are not explicitly modeled. A greater performance was achieved by the expert-driven approach for DR detection, where the designer had sound expert knowledge. However, for both problems, a comparable performance was obtained for both expert- and data-driven approaches. This indicates that annotation of a limited number of lesions suffices for building a detection system for any type of lesion in retinal images, if no expert-knowledge is available. We are studying whether the optimal filter framework also generalizes to the detection of any structure in other domains.
Collapse
Affiliation(s)
- Gwénolé Quellec
- Department of Ophthalmology and Visual Sciences, University of Iowa, Iowa City, IA 52242, USA.
| | | | | |
Collapse
|
183
|
Antal B, Lázár I, Hajdu A, Török Z, Csutak A, Peto T. Evaluation of the grading performance of an ensemble-based microaneurysm detector. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2011; 2011:5943-5946. [PMID: 22255693 DOI: 10.1109/iembs.2011.6091469] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
In this paper, results of a diabetic retinopathy screening experiment are presented which is based solely on the findings of a microaneurysm detector. For this purpose, an ensemble-based algorithm developed by our research group was used; this provided promising results in our earlier experiments. At its best, the 1200 image of the Messidor database is classified by this detector with a sensitivity of 96%, a specificity of 51% and achieved an AUC of 0.87. As anticipated, larger microaneurysm counts are recognized with higher level of certainty. Therefore, this approach might be expected to have good performance in relation to the severity of the disease.
Collapse
Affiliation(s)
- Bálint Antal
- Faculty of Informatics, University of Debrecen, 4010 Debrecen, POB 12, Hungary.
| | | | | | | | | | | |
Collapse
|
184
|
García M, López MI, Alvarez D, Hornero R. Assessment of four neural network based classifiers to automatically detect red lesions in retinal images. Med Eng Phys 2010; 32:1085-93. [PMID: 20739211 DOI: 10.1016/j.medengphy.2010.07.014] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2009] [Revised: 05/20/2010] [Accepted: 07/26/2010] [Indexed: 10/19/2022]
Abstract
Diabetic retinopathy (DR) is an important cause of visual impairment in industrialised countries. Automatic detection of DR early markers can contribute to the diagnosis and screening of the disease. The aim of this study was to automatically detect one of such early signs: red lesions (RLs), like haemorrhages and microaneurysms. To achieve this goal, we extracted a set of colour and shape features from image regions and performed feature selection using logistic regression. Four neural network (NN) based classifiers were subsequently used to obtain the final segmentation of RLs: multilayer perceptron (MLP), radial basis function (RBF), support vector machine (SVM) and a combination of these three NNs using a majority voting (MV) schema. Our database was composed of 115 images. It was divided into a training set of 50 images (with RLs) and a test set of 65 images (40 with RLs and 25 without RLs). Attending to performance and complexity criteria, the best results were obtained for RBF. Using a lesion-based criterion, a mean sensitivity of 86.01% and a mean positive predictive value of 51.99% were obtained. With an image-based criterion, a mean sensitivity of 100%, mean specificity of 56.00% and mean accuracy of 83.08% were achieved.
Collapse
Affiliation(s)
- María García
- Grupo de Ingeniería Biomédica, E.T.S. Ingenieros de Telecomunicación, University of Valladolid, Paseo Belén 15, 47011 Valladolid, Spain.
| | | | | | | |
Collapse
|
185
|
Abramoff MD, Niemeijer M, Russell SR. Automated detection of diabetic retinopathy: barriers to translation into clinical practice. Expert Rev Med Devices 2010; 7:287-96. [PMID: 20214432 DOI: 10.1586/erd.09.76] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Automated identification of diabetic retinopathy (DR), the primary cause of blindness and visual loss for those aged 18-65 years, from color images of the retina has enormous potential to increase the quality, cost-effectiveness and accessibility of preventative care for people with diabetes. Through advanced image analysis techniques, retinal images are analyzed for abnormalities that define and correlate with the severity of DR. Translating automated DR detection into clinical practice will require surmounting scientific and nonscientific barriers. Scientific concerns, such as DR detection limits compared with human experts, can be studied and measured. Ethical, legal and political issues can be addressed, but are difficult or impossible to measure. The primary objective of this review is to survey the methods, potential benefits and limitations of automated detection in order to better manage translation into clinical practice, based on extensive experience with the systems we have developed.
Collapse
Affiliation(s)
- Michael D Abramoff
- Department of Ophthalmology and Visual Sciences, University of Iowa, 11290C PFP UIHC, 200 Hawkins Drive, Iowa City, IA 52242, USA.
| | | | | |
Collapse
|
186
|
Abràmoff MD, Reinhardt JM, Russell SR, Folk JC, Mahajan VB, Niemeijer M, Quellec G. Automated early detection of diabetic retinopathy. Ophthalmology 2010; 117:1147-54. [PMID: 20399502 PMCID: PMC2881172 DOI: 10.1016/j.ophtha.2010.03.046] [Citation(s) in RCA: 102] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2009] [Revised: 03/18/2010] [Accepted: 03/19/2010] [Indexed: 11/16/2022] Open
Abstract
PURPOSE To compare the performance of automated diabetic retinopathy (DR) detection, using the algorithm that won the 2009 Retinopathy Online Challenge Competition in 2009, the Challenge2009, against that of the one currently used in EyeCheck, a large computer-aided early DR detection project. DESIGN Evaluation of diagnostic test or technology. PARTICIPANTS Fundus photographic sets, consisting of 2 fundus images from each eye, were evaluated from 16670 patient visits of 16,670 people with diabetes who had not previously been diagnosed with DR. METHODS The fundus photographic set from each visit was analyzed by a single retinal expert; 793 of the 16,670 sets were classified as containing more than minimal DR (threshold for referral). The outcomes of the 2 algorithmic detectors were applied separately to the dataset and were compared by standard statistical measures. MAIN OUTCOME MEASURES The area under the receiver operating characteristic curve (AUC), a measure of the sensitivity and specificity of DR detection. RESULTS Agreement was high, and examination results indicating more than minimal DR were detected with an AUC of 0.839 by the EyeCheck algorithm and an AUC of 0.821 for the Challenge2009 algorithm, a statistically nonsignificant difference (z-score, 1.91). If either of the algorithms detected DR in combination, the AUC for detection was 0.86, the same as the theoretically expected maximum. At 90% sensitivity, the specificity of the EyeCheck algorithm was 47.7% and that of the Challenge2009 algorithm was 43.6%. CONCLUSIONS Diabetic retinopathy detection algorithms seem to be maturing, and further improvements in detection performance cannot be differentiated from best clinical practices, because the performance of competitive algorithm development now has reached the human intrareader variability limit. Additional validation studies on larger, well-defined, but more diverse populations of patients with diabetes are needed urgently, anticipating cost-effective early detection of DR in millions of people with diabetes to triage those patients who need further care at a time when they have early rather than advanced DR.
Collapse
Affiliation(s)
- Michael D Abràmoff
- Department of Ophthalmology and Visual Sciences, University of Iowa Hospitals and Clinics, Iowa City, Iowa 52242, USA
| | | | | | | | | | | | | |
Collapse
|
187
|
Abstract
Many important eye diseases as well as systemic diseases manifest themselves in the retina. While a number of other anatomical structures contribute to the process of vision, this review focuses on retinal imaging and image analysis. Following a brief overview of the most prevalent causes of blindness in the industrialized world that includes age-related macular degeneration, diabetic retinopathy, and glaucoma, the review is devoted to retinal imaging and image analysis methods and their clinical implications. Methods for 2-D fundus imaging and techniques for 3-D optical coherence tomography (OCT) imaging are reviewed. Special attention is given to quantitative techniques for analysis of fundus photographs with a focus on clinically relevant assessment of retinal vasculature, identification of retinal lesions, assessment of optic nerve head (ONH) shape, building retinal atlases, and to automated methods for population screening for retinal diseases. A separate section is devoted to 3-D analysis of OCT images, describing methods for segmentation and analysis of retinal layers, retinal vasculature, and 2-D/3-D detection of symptomatic exudate-associated derangements, as well as to OCT-based analysis of ONH morphology and shape. Throughout the paper, aspects of image acquisition, image analysis, and clinical relevance are treated together considering their mutually interlinked relationships.
Collapse
Affiliation(s)
- Michael D Abràmoff
- Department of Ophthalmology and Visual Sciences, University of Iowa, Iowa City, IA 52242, USA
| | | | | |
Collapse
|