151
|
|
152
|
Effect of the forward-projected model-based iterative reconstruction solution algorithm on image quality and radiation dose in pediatric cardiac computed tomography. Pediatr Radiol 2016; 46:1663-1670. [PMID: 27531216 DOI: 10.1007/s00247-016-3676-x] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/01/2016] [Revised: 05/22/2016] [Accepted: 07/20/2016] [Indexed: 10/21/2022]
Abstract
BACKGROUND Some iterative reconstruction algorithms are useful for reducing the radiation dose in pediatric cardiac CT. A new iterative reconstruction algorithm (forward-projected model-based iterative reconstruction solution) has been developed, but its usefulness for radiation dose reduction in pediatric cardiac CT is unknown. OBJECTIVE To investigate the effect of the new algorithm on CT image quality and on radiation dose in pediatric cardiac CT. MATERIALS AND METHODS We obtained phantom data at six dose levels, as well as pediatric cardiac CT data, and reconstructed CT images using filtered back projection, adaptive iterative dose reduction 3-D (AIDR 3-D) and the new algorithm. We evaluated phantom image quality using physical assessment. Four radiologists performed visual evaluation of cardiac CT image quality. RESULTS In the phantom study, the new algorithm effectively suppressed noise in the low-dose range and moderately generated modulation transfer function, yielding a higher signal-to-noise ratio compared with filtered back projection or AIDR 3-D. When clinical cardiac CT was performed, images obtained by the new method had less perceived image noise and better tissue contrast at similar resolution compared with AIDR 3-D images. CONCLUSION The new algorithm reduced image noise at moderate resolution in low-dose CT scans and improved the perceived quality of cardiac CT images to some extent. This new algorithm might be superior to AIDR 3-D for radiation dose reduction in pediatric cardiac CT.
Collapse
|
153
|
Schmid AI, Uder M, Lell MM. Reaching for better image quality and lower radiation dose in head and neck CT: advanced modeled and sinogram-affirmed iterative reconstruction in combination with tube voltage adaptation. Dentomaxillofac Radiol 2016; 46:20160131. [PMID: 27540625 DOI: 10.1259/dmfr.20160131] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
OBJECTIVES The aim of this study was to evaluate image quality and radiation dose in low-dose head and neck CT comparing two different commercially available iterative reconstruction algorithms: sinogram-affirmed iterative reconstruction (SAFIRE) and advanced modeled iterative reconstruction (ADMIRE) with fixed and automated tube voltage adaptation (TVA). METHODS CT examinations of 103 patients were analysed. 58 patients were examined on a single-source CT at fixed tube voltage of 120 kV and reconstructed with filtered back projection (FBP) and SAFIRE (Strength Level 3). 45 patients were examined in a single-source mode on a dual-source CT with automated TVA and reconstructed with FBP and ADMIRE (Strength Levels 2 and 3). Image noise was calculated in seven anatomical volumes of interest. Subjective evaluation of the CT images was performed using a four-grade scale. RESULTS Mean CT numbers of FBP and the corresponding iterative reconstruction did not differ significantly (p = 0.74-0.99). Image noise was lower with both iterative reconstruction techniques than with FBP (SAFIRE 3: -22.3%; ADMIRE 2: -14.9%; ADMIRE 3: -24.2%; all p < 0.05); hence, the signal-to-noise ratio and the contrast-to-noise values were higher. Subjective image quality revealed a more favourable result for the iterative reconstruction. ADMIRE 3 in combination with automated TVA showed 14.4% (p < 0.05) less image noise with a 7.5% lower radiation dose than SAFIRE 3 with fixed tube voltage. CONCLUSIONS Higher image quality at lower radiation dose can be achieved using ADMIRE in combination with automated TVA.
Collapse
Affiliation(s)
- Andrea I Schmid
- 1 Department of Radiology, University Hospital Erlangen, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Germany
| | - Michael Uder
- 1 Department of Radiology, University Hospital Erlangen, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Germany.,2 Imaging Science Institute (ISI) Erlangen, Department of Radiology, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Germany
| | - Michael M Lell
- 1 Department of Radiology, University Hospital Erlangen, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Germany.,3 Department of Radiology and Nuclear Medicine, Klinikum Nürnberg, Germany, Paracelsus Medical University
| |
Collapse
|
154
|
Shen Y, Hu X, Zou X, Zhu D, Li Z, Hu D. Did low tube voltage CT combined with low contrast media burden protocols accomplish the goal of "double low" for patients? An overview of applications in vessels and abdominal parenchymal organs over the past 5 years. Int J Clin Pract 2016; 70 Suppl 9B:B5-B15. [PMID: 27577514 DOI: 10.1111/ijcp.12861] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/04/2015] [Accepted: 06/15/2016] [Indexed: 01/29/2023] Open
Abstract
BACKGROUND Imaging communities have already reached a consensus that the radiation dose of computed tomography (CT) should be reduced as much as reasonably achievable to lower population risks. Increasing attention is being paid to iodinated contrast media (CM) induced nephrotoxicity (CIN); a decrease in the intake of iodinated CM is required by increasingly more radiologists. Theoretically, the radiation dose varies with the tube current time and square of the tube voltage, with higher iodine contrast at low photon energies (Huda et al. [2000] Radiology, 21 7, 430-435).The use of low tube voltage is a promising strategy to reduce both the radiation dose and CM burden. The term 'double low' has been coined to describe scanning protocols that reduce radiation dose and iodine intake synchronously. These protocols are becoming increasingly popular in the clinical setting. PURPOSE The aim of this review was to describe all original studies using the 'double low' strategy in the last 5 years. METHODS We searched an online electronic database (PubMed) from January 2011 to December 2015 for original studies published on the relationship of low tube voltage with low radiation dose and low iodine contrast media burden in patients undergoing CT scans. Studies that failed to reduce radiation dose or iodine CM burden were excluded in this study. RESULTS Thirty-seven studies aimed at reducing radiation dose using low tube voltage combined with iodine CM reduced protocols were included in this study. Most studies evaluated conditions associated with arteries. Four were cerebral and neck computed tomography angiography (CTA) studies, 15 were pulmonary CTA (pCTA) and coronary CTA (cCTA) studies, one concerned myocardial perfusion, five studies focused on the thoracic and abdominal aorta, and one investigated renal arteries. Three studies consisted of CT venography (CTV) of the pelvis and lower extremities. Six publications examined the liver, and two focused on the kidney. CONCLUSION Overall, this review demonstrates that the low tube voltage CT protocol is a powerful tool to reduce the radiation dose in CTA, especially with pCTA and cCTA.
Collapse
Affiliation(s)
- Yaqi Shen
- Departments of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, People's Republic of China
| | - Xuemei Hu
- Departments of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, People's Republic of China
| | - Xianlun Zou
- Departments of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, People's Republic of China
| | - Di Zhu
- Departments of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, People's Republic of China
| | - Zhen Li
- Departments of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, People's Republic of China
| | - Daoyu Hu
- Departments of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, People's Republic of China
| |
Collapse
|
155
|
|
156
|
|
157
|
Park JH, Kim B, Kim MS, Kim HJ, Ko Y, Ahn S, Karul M, Fletcher JG, Lee KH. Comparison of filtered back projection and iterative reconstruction in diagnosing appendicitis at 2-mSv CT. Abdom Radiol (NY) 2016; 41:1227-36. [PMID: 27315093 DOI: 10.1007/s00261-015-0632-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
PURPOSE To compare radiologists' diagnostic performance and confidence, and subjective image quality between filtered back projection (FBP) and iterative reconstruction (IR) at 2-mSv appendiceal CT. METHODS The institutional review board approved this retrospective study and waived the requirement for informed consent. We included 107 adolescents and young adults (age, 29.8 ± 8.5 years; 64 females) undergoing 2-mSv CT for suspected appendicitis. Appendicitis was pathologically confirmed in 42 patients. Seven readers with different experience levels independently reviewed the CT images reconstructed using FBP and IR (iDose(4), Philips). They rated both the likelihood of appendicitis and subjective image quality on 5-point Likert scales. Diagnostic confidence was assessed using the likelihood of appendicitis, proportion of indeterminate interpretations, and 3-point normal appendix visualization score. We used receiver operating characteristic analyses, Wilcoxon's signed-rank tests, and McNemar's tests. RESULTS The pooled area under the receiver operating characteristic curve (AUC) was 0.96 for both FBP and IR (95% CI for the difference, -0.02, 0.02; P = 0.73). The AUC difference was not significant in any of the individual readers (P ≥ 0.21). For the majority of the readers, the diagnostic confidence was not significantly different between the two reconstruction methods. Subjective image quality tended to be higher with IR for all readers (P ≤ 0.70), showing significant differences for four readers (P ≤ 0.040). CONCLUSION When diagnosing appendicitis at 2-mSv CT in adolescents and young adults, FBP and IR were comparable in radiologists' diagnostic performance and confidence while IR exhibited higher subjective image quality than FBP.
Collapse
|
158
|
Shearer T, Bradley RS, Hidalgo-Bastida LA, Sherratt MJ, Cartmell SH. Three-dimensional visualisation of soft biological structures by X-ray computed micro-tomography. J Cell Sci 2016; 129:2483-92. [PMID: 27278017 DOI: 10.1242/jcs.179077] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Whereas the two-dimensional (2D) visualisation of biological samples is routine, three-dimensional (3D) imaging remains a time-consuming and relatively specialised pursuit. Current commonly adopted techniques for characterising the 3D structure of non-calcified tissues and biomaterials include optical and electron microscopy of serial sections and sectioned block faces, and the visualisation of intact samples by confocal microscopy or electron tomography. As an alternative to these approaches, X-ray computed micro-tomography (microCT) can both rapidly image the internal 3D structure of macroscopic volumes at sub-micron resolutions and visualise dynamic changes in living tissues at a microsecond scale. In this Commentary, we discuss the history and current capabilities of microCT. To that end, we present four case studies to illustrate the ability of microCT to visualise and quantify: (1) pressure-induced changes in the internal structure of unstained rat arteries, (2) the differential morphology of stained collagen fascicles in tendon and ligament, (3) the development of Vanessa cardui chrysalises, and (4) the distribution of cells within a tissue-engineering construct. Future developments in detector design and the use of synchrotron X-ray sources might enable real-time 3D imaging of dynamically remodelling biological samples.
Collapse
Affiliation(s)
- Tom Shearer
- School of Materials, University of Manchester, Manchester M13 9PL, UK School of Mathematics, University of Manchester, Manchester M13 9PL, UK
| | - Robert S Bradley
- Henry Moseley X-ray Imaging Facility, School of Materials, University of Manchester, Manchester M13 9PL, UK
| | | | - Michael J Sherratt
- Institute of Inflammation and Repair, University of Manchester, Manchester M13 9PL, UK
| | - Sarah H Cartmell
- School of Materials, University of Manchester, Manchester M13 9PL, UK
| |
Collapse
|
159
|
Zhou Y, Xu H, Hou P, Dong JQ, Wang MY, Gao JB. Monochromatic Spectral Computed Tomography with Low Iodine Concentration Contrast Medium in a Rabbit VX2 Liver Model:: Investigation of Image Quality and Detection Rate. Acad Radiol 2016; 23:486-95. [PMID: 26795435 DOI: 10.1016/j.acra.2015.12.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2015] [Revised: 11/17/2015] [Accepted: 12/03/2015] [Indexed: 11/25/2022]
Abstract
RATIONALE AND OBJECTIVES This study aimed to validate the feasibility of using virtual monochromatic spectral computed tomography (CT) with isotonic low iodine concentration contrast medium for VX2 hepatic tumors. MATERIALS AND METHODS Sixty New Zealand white rabbits with implanted VX2 hepatic tumors underwent two-phase contrast-enhanced spectral CT imaging on the 14th day after tumor implantation. They were randomly divided into groups A, B, and C, with 20 rabbits each (group A: 270 mg I/mL, monochromatic spectral images; group B: 370 mg I/mL, conventional 120 kVp images, 100% filtered back projection [FBP]; group C: 270 mg I/mL, conventional 120 kVp images, 100% FBP). Group A was further divided into two subgroups (subgroup A1: 100% FBP; subgroup A2: 50% FBP + 50% adaptive statistical iterative reconstruction). Objective evaluation (signal-to-noise ratio [SNR], contrast-to-noise ratio [CNR], and image noise), subjective rating score (image noise score, anatomical details score, overall image quality score, and lesion conspicuity score), CT dose index volume, and dose length product were compared between groups during two-phase contrast enhancement. The detection rates of the four groups were calculated as percentages. RESULTS Image noise (SNR and CNR) among the four groups was statistically significant (P <0.05). The image noise in group A2 was lower than in group A1, but higher than that in groups B and C (P <0.05). SNR and CNR in group A2 were the highest, followed by group A1, and group C was the lowest (P <0.05 for all). The image noise score of group A2 was higher than that of the other three groups. In terms of the anatomic details score, the overall image quality score, and the lesion conspicuity score, the images of group A2 were superior to that of groups A1 and C. For hepatic tumor diameters more than or equal to 1.0 cm and less than 3.0 cm, group A achieved a higher detection rate than groups B and C. The CT dose index volume, dose length product, and effective dose in group A were significantly lower than that in groups B and C (P <0.05). On average, group A reduced the effective radiation dose by 27.2% compared to group B, whereas group B reduced the effective radiation dose by 28% compared to group C. Group A reduced the iodine load by 22.86% compared to group B. CONCLUSIONS The use of monochromatic images combined with 50% adaptive statistical iterative reconstruction with an isotonic low concentration contrast medium of 270 mg I/mL can optimize image quality, reduce image noise, increase detection rate for small tumors, and decrease radiation dose and iodine load in hepatic tumor CT examinations.
Collapse
|
160
|
Lamba R, Corwin MT, Fananapazir G. Practical dose reduction tips for abdominal interventional procedures using CT-guidance. Abdom Radiol (NY) 2016; 41:743-53. [PMID: 26920005 DOI: 10.1007/s00261-016-0670-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Reducing the radiation dose should be an endeavor not only for diagnostic CT exams but also for interventional procedures using CT-guidance. Given that interventional procedures vary in scope and complexity, there is greater variability in radiation doses delivered during CT procedures. The goal in an interventional procedure is simply to advance the interventional instruments into the target lesions, and as such diagnostic level doses are not required and only narrow scan range scans need to be acquired. Adherence to the principles outlined in this article will allow such procedures to be performed with reduced radiation doses.
Collapse
Affiliation(s)
- Ramit Lamba
- Department of Radiology, University of California Davis Medical Center, 4860 Y Street, Sacramento, CA, 95817, USA.
| | - Michael T Corwin
- Department of Radiology, University of California Davis Medical Center, 4860 Y Street, Sacramento, CA, 95817, USA
| | - Ghaneh Fananapazir
- Department of Radiology, University of California Davis Medical Center, 4860 Y Street, Sacramento, CA, 95817, USA
| |
Collapse
|
161
|
Shi YJ, Zhang XP, Sun YS, Qi LP, Li Y, Zhu HB, Li XT, Zhang XY. Spectral CT in the Demonstration of the Pancreatic Arteries and Their Branches: A Comparison With Conventional CT. Medicine (Baltimore) 2016; 95:e2823. [PMID: 26886636 PMCID: PMC4998636 DOI: 10.1097/md.0000000000002823] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
The aim of this study was to investigate the performance of monochromatic images of spectral computed tomographic (CT) in the visualization of the pancreatic arteries compared with polychromatic CT images. We conducted a case-control study in a group of 26 consecutive patients with monochromatic CT and contrasted the results against a control group of 26 consecutive patients with polychromatic CT. The CNR (contrast-to-noise ratio), SIR (signal intensity ratio), SNR (signal to noise ratio), and image noise were measured. A 5-score classification system was used to evaluate the branch order of pancreatic arteries. The course of pancreatic arteries was compared. Compared with polychromatic images, the CNR, SIR, and SNR obtained by monochromatic images were increased by 64.74%, 23.99%, and 39.50%. Branch visualization of PSPDA (posterior superior pancreaticoduodenal artery), ASPDA (anterior superior pancreaticoduodenal artery), and DPA (dorsal pancreatic artery) was better at monochromatic images than at polychromatic images. The display rate was significantly better in monochromatic images for the second and third segments of PSPDA, total course of ASPDA, and artery of uncinate process. Compared with polychromatic images, monochromatic images can improve the visualization of pancreatic arteries.
Collapse
Affiliation(s)
- Yan-Jie Shi
- From the Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education), Department of Radiology, Peking University Cancer Hospital & Institute, Beijing, China
| | | | | | | | | | | | | | | |
Collapse
|
162
|
Blum A, Gervaise A, Teixeira P. Iterative reconstruction: Why, how and when? Diagn Interv Imaging 2015; 96:421-2. [DOI: 10.1016/j.diii.2015.04.003] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|