1
|
Chen X, Cao H, Huo Y, Song J, Zou H, Li J, Hou J, Wang Y. Screening of sensitive in vivo characteristics for early keratoconus diagnosis: a multicenter study. Front Bioeng Biotechnol 2023; 11:1158299. [PMID: 37600309 PMCID: PMC10436515 DOI: 10.3389/fbioe.2023.1158299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Accepted: 07/21/2023] [Indexed: 08/22/2023] Open
Abstract
Purpose: To analyze and compare sensitive in vivo characteristics for screening early keratoconus. Methods: This multicenter, case-control study included 712 eyes, after matching for age and biomechanically corrected intraocular pressure, from three clinics in different cities. The keratoconus (n = 288), early keratoconus (n = 91), and normal cornea (n = 333) groups included eyes diagnosed with bilateral keratoconus, fellow eyes with relatively normal topography with unilateral keratoconus, and normal eyes before refractive surgery, respectively. After adjusting for central corneal thickness, differences in vivo characteristics were analyzed among the three groups. The in vivo characteristics were measured by Pentacam and Corvis ST. Fifty-four indices were evaluated to screen for a sensitive index for the detection of early keratoconus. Results: Significant differences were observed in 26 of the 36 corneal biomechanical indeces between the early keratoconus and normal corneas. The area under the receiver operating characteristic curve of tomographic and biomechanical index, Belin/Ambrósio deviation, and Da in differentiating keratoconus from normal cornea was 1.000. Among the top five indeces of the area under the receiver operating characteristic curve for detecting early keratoconus, the corneal biomechanical-related index accounted for 80% (4/5), including A1 dArc length, highest concavity radius, A2 time, and tomographic and biomechanical index, of which the area under the receiver operating characteristic curve of A1 dArc length was 0.901. Conclusion: A1 dArc length and several corneal biomechanical indices are highly sensitive for the detection of early keratoconus, even in the absence of topographic abnormalities. Ophthalmologists should focus on the clinical application of corneal biomechanics and combine corneal tomography for the timely and accurate detection of early keratoconus.
Collapse
Affiliation(s)
- Xuan Chen
- School of Medicine, Nankai University, Tianjin, China
| | - Huazheng Cao
- School of Medicine, Nankai University, Tianjin, China
| | - Yan Huo
- School of Medicine, Nankai University, Tianjin, China
| | - Jiaxin Song
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China
| | - Haohan Zou
- Tianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Nankai University Affiliated Eye Hospital, Tianjin, China
| | - Jing Li
- Shanxi Eye Hospital, Xi’an People’s Hospital, Xi’an, Shanxi, China
| | - Jie Hou
- Jinan Mingshui Eye Hospital, Jinan, Shandong, China
| | - Yan Wang
- School of Medicine, Nankai University, Tianjin, China
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China
- Tianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Nankai University Affiliated Eye Hospital, Tianjin, China
- Nankai Eye Institute, Nankai University, Tianjin, China
| |
Collapse
|
2
|
Transepithelial Photorefractive Keratectomy Compared to Conventional Photorefractive Keratectomy: A Meta-Analysis. J Ophthalmol 2022; 2022:3022672. [PMID: 36051276 PMCID: PMC9427238 DOI: 10.1155/2022/3022672] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2022] [Accepted: 07/30/2022] [Indexed: 12/01/2022] Open
Abstract
This meta-analysis review compares the primary and secondary outcomes of transepithelial photorefractive keratectomy (TPRK) to the conventional photorefractive keratectomy (PRK), in terms of efficacy, predictability, safety, and patient perspectives. A total of 1711 eyes with PRK (811 eyes) and TPRK (900 eyes) from 12 studies were included through bibliographic searches. The main outcomes were efficacy, predictability, and safety parameters, and the secondary outcomes included visual and patient-reported parameters. The effect measures were weighted mean differences with 95% confidence intervals (CI) which were derived from the random-effects model of the meta-analysis to account for possible heterogeneity. TPRK procedure presents a comparable status in the main outcome and a very dominant significance in all the secondary outcomes in this meta-analysis. This study updates the evidence of the accuracy of TPRK procedure for surgical correction of all refractive errors and was deemed safer with less surgical time required and an early healing time.
Collapse
|
3
|
Yu N, Chen S, Yang X, Hou X, Wan L, Huang Y, Qiu J, Li Y, Zheng H, Wei H, Zeng C, Lei L, Chen P, Yang Y, Quan D, Zhuang J, Yu K. Comparison of fresh and preserved decellularized human corneal lenticules in femtosecond laser-assisted intrastromal lamellar keratoplasty. Acta Biomater 2022; 150:154-167. [PMID: 35896137 DOI: 10.1016/j.actbio.2022.07.035] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Revised: 07/14/2022] [Accepted: 07/19/2022] [Indexed: 11/30/2022]
Abstract
Substantial evidence has demonstrated the application of fresh and decellularized human corneal lenticules from increasing myopic surgeries. Further preservation of decellularized corneal lenticules would extend its clinical application. However, whether fresh and preserved decellularized lenticules have the same effects in vivo, including refractive correction, remains unclear. Here, we made comprehensive comparisons between fresh human lenticules (FHLs) and preserved decellularized human lenticules (DHLs). Another group of decellularized lenticules was combined with crosslinking for potential keratoconus therapy. Optical transparency, biomechanical properties, and fibrillar ultrastructure were analyzed to evaluate the DHLs and crosslinked DHLs (cDHLs) in vitro. The DHLs retained high transparency and regular ultrastructure, with genetic materials mostly being eliminated. The strength of lenticules in the cDHL group was markedly increased by crosslinking. Moreover, after storage in glycerol for 3 months, the lenticules were reimplanted into rabbit corneal lamellar pockets assisted by a femtosecond laser. The rabbits were followed for another 3 months. There were no obvious rejective complications in any of the three groups. From 1 week to 3 months postoperatively, the host corneas of the FHL group remained highly transparent, while slight hazes were observed in the DHL group. However, the corneas of the cDHL group displayed opacity throughout the 3-month postoperative period. Furthermore, all the lenticules could effectively induce corneal steepening and refractive changes. Taken together, our data indicated that FHLs are ideal inlay products, whereas preserved DHLs could be an alternative for intrastromal lamellar keratoplasty. Our study provides new insights into the clinical application of human lenticule recycling. STATEMENT OF SIGNIFICANCE: : Currently, substantial evidence has demonstrated the application of fresh and decellularized human corneal lenticules from increasing myopic surgeries. Further preservation of decellularized lenticules would extend its clinical application. However, whether fresh and preserved decellularized lenticules have the same effects in vivo, including refractive correction, remains unclear. Herein, we decellularized human lenticules with or without mechanically strengthened crosslinking. After storage in glycerol for 3 months, the lenticules were reimplanted into rabbit corneas. Comprehensive comparisons were performed among fresh human lenticules (FHLs), decellularized human lenticules (DHLs) and crosslinked DHLs. Our study indicated that FHLs are ideal inlay products, whereas preserved DHLs could be an alternative for intrastromal lamellar keratoplasty. Our study provides new insights into the clinical application of human lenticule recycling.
Collapse
Affiliation(s)
- Na Yu
- State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Zhongshan Ophthalmic Center, Sun Yat-sen University, P. R. China 510060
| | - Shuilian Chen
- State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Zhongshan Ophthalmic Center, Sun Yat-sen University, P. R. China 510060
| | - Xifeng Yang
- PCFM Lab, GD HPPC Lab, School of Chemistry, and Guangdong Functional Biomaterials Engineering Technology Research Center, School of Materials Science and Engineering, Sun Yat-Sen University, P. R. China 510275
| | - Xiangtao Hou
- State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Zhongshan Ophthalmic Center, Sun Yat-sen University, P. R. China 510060
| | - Linxi Wan
- State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Zhongshan Ophthalmic Center, Sun Yat-sen University, P. R. China 510060
| | - Yuke Huang
- State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Zhongshan Ophthalmic Center, Sun Yat-sen University, P. R. China 510060
| | - Jin Qiu
- State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Zhongshan Ophthalmic Center, Sun Yat-sen University, P. R. China 510060
| | - Yan Li
- State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Zhongshan Ophthalmic Center, Sun Yat-sen University, P. R. China 510060
| | - Hua Zheng
- State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Zhongshan Ophthalmic Center, Sun Yat-sen University, P. R. China 510060
| | - Han Wei
- State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Zhongshan Ophthalmic Center, Sun Yat-sen University, P. R. China 510060
| | - Chenguang Zeng
- Guangzhou Sun-shing Biotech Co., Ltd, P. R. China 510060
| | - Lei Lei
- State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Zhongshan Ophthalmic Center, Sun Yat-sen University, P. R. China 510060
| | - Pei Chen
- State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Zhongshan Ophthalmic Center, Sun Yat-sen University, P. R. China 510060
| | - Ying Yang
- State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Zhongshan Ophthalmic Center, Sun Yat-sen University, P. R. China 510060
| | - Daping Quan
- PCFM Lab, GD HPPC Lab, School of Chemistry, and Guangdong Functional Biomaterials Engineering Technology Research Center, School of Materials Science and Engineering, Sun Yat-Sen University, P. R. China 510275.
| | - Jing Zhuang
- State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Zhongshan Ophthalmic Center, Sun Yat-sen University, P. R. China 510060.
| | - Keming Yu
- State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Zhongshan Ophthalmic Center, Sun Yat-sen University, P. R. China 510060.
| |
Collapse
|
4
|
Ahn H, Jun I, Seo KY, Kim EK, Kim TI. Femtosecond laser-assisted cataract surgery after corneal refractive surgery. Sci Rep 2022; 12:4263. [PMID: 35277568 PMCID: PMC8917192 DOI: 10.1038/s41598-022-08297-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Accepted: 03/04/2022] [Indexed: 11/24/2022] Open
Abstract
Cataract is the leading cause of blindness worldwide, and advanced cataract techniques such as femtosecond laser-assisted cataract surgery (FLACS) have been commercially available. Corneal refractive surgery (CRS) is one of the most popular surgeries for the correction of refractive errors. CRS changes the cornea not only anatomically but also pathophysiologically. However, there has been no clinical research analyzing the refractive and safety outcomes of FLACS after CRS. The aim of this retrospective chart review and comparative study is to evaluate the effect and safety of FLACS after CRS comparing with conventional PCS. Participants with a previous CRS history who underwent FLACS or conventional PCS were included in this study. The visual outcomes and the refractive outcomes including refractive, corneal, and ocular residual astigmatism were compared. The safety outcomes were then studied intraoperatively and postoperatively. A total of 102 patients with age-related cataract were enrolled. At 3 months postoperatively, UCVA, BCVA, and predictive error were not significantly different between the FLACS and conventional PCS groups. Reduction of refractive astigmatism was higher in FLACS. Postoperative ORA was significant lower in FLACS. Reduction of ORA was higher in FLACS. The intraoperative and postoperative complications were also not significantly different between the two groups. FLACS could effectively change refractive astigmatism and ORA; without more complications than conventional PCS. FLACS’ competitive edge in postoperative ORA may provide better visual quality than conventional PCS in patients with a previous history of CRS.
Collapse
Affiliation(s)
- Hyunmin Ahn
- Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea
| | - Ikhyun Jun
- Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea.,Department of Ophthalmology, Corneal Dystrophy Research Institute, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemungu, Seoul, 03722, Korea
| | - Kyoung Yul Seo
- Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea
| | - Eung Kweon Kim
- Department of Ophthalmology, Corneal Dystrophy Research Institute, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemungu, Seoul, 03722, Korea.,Saevit Eye Hospital, Goyang, Gyunggi-do, Korea
| | - Tae-Im Kim
- Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea. .,Department of Ophthalmology, Corneal Dystrophy Research Institute, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemungu, Seoul, 03722, Korea.
| |
Collapse
|
5
|
Zhuo Y, Cheng X, Fang H, Zhang Y, Wang B, Jia S, Li W, Yang X, Zhang Y, Wang X. Medical gloves modified by a one-minute spraying process with blood-repellent, antibacterial and wound-healing abilities. Biomater Sci 2022; 10:939-946. [PMID: 35037011 DOI: 10.1039/d1bm01212f] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
During clinical surgery, bleeding that occurs in the operative region is inevitable. Due to the blood adhesion on ordinary medical gloves, it reduces surgery quality to a certain extent and even prolongs operation time. Herein, we show that medical blood-repellent gloves (MBRG) can be obtained by spraying the blood-repellent mist spray (MS) on the surface of ordinary medical gloves, which are available for immediate use in around one minute. After the modification, MBRG not only have a significantly higher blood repellent rate than that of ordinary medical gloves, but also can effectively inhibit the growth of Staphylococcus aureus (S. aureus) and Escherichia coli (E. coli), and even promote the healing of infected wounds. MS is easy to prepare, low-toxic, and can be widely used on the surface of various medical gloves, such as rubber gloves, polyethylene film gloves, and nitrile gloves, which may have an impact on the development of future medical gloves.
Collapse
Affiliation(s)
- Yi Zhuo
- The Second Affiliated Hospital, Nanchang University, Nanchang, Jiangxi 330088, China.
| | - Xinyan Cheng
- School of Materials Science and Engineering, Nanchang University, Nanchang, Jiangxi 330088, China
| | - Hua Fang
- The Second Affiliated Hospital, Nanchang University, Nanchang, Jiangxi 330088, China.
| | - Yi Zhang
- The Second Affiliated Hospital, Nanchang University, Nanchang, Jiangxi 330088, China.
| | - Bing Wang
- The Second Affiliated Hospital, Nanchang University, Nanchang, Jiangxi 330088, China.
| | - Shuang Jia
- The National Engineering Research Center for Bioengineering Drugs and the Technologies, Institute of Translational Medicine, Nanchang University, Nanchang, Jiangxi 330088, China
| | - Weihao Li
- The National Engineering Research Center for Bioengineering Drugs and the Technologies, Institute of Translational Medicine, Nanchang University, Nanchang, Jiangxi 330088, China
| | - Xuetao Yang
- The National Engineering Research Center for Bioengineering Drugs and the Technologies, Institute of Translational Medicine, Nanchang University, Nanchang, Jiangxi 330088, China
| | - Yan Zhang
- The Second Affiliated Hospital, Nanchang University, Nanchang, Jiangxi 330088, China.
| | - Xiaolei Wang
- The National Engineering Research Center for Bioengineering Drugs and the Technologies, Institute of Translational Medicine, Nanchang University, Nanchang, Jiangxi 330088, China.,College of Chemistry, Nanchang University, Nanchang, Jiangxi 330088, China.
| |
Collapse
|