1
|
Gupta K, Villablanca P, Gonzalez PE, O’Neill B, O’Neill WW, Wang DD, Fang JX, Giustino G, Frisoli T, Lee JC. Association of Relative Left Ventricular Outflow Tract Area and Transcatheter Aortic Valve Replacement Related Paravalvular Leak. JOURNAL OF THE SOCIETY FOR CARDIOVASCULAR ANGIOGRAPHY & INTERVENTIONS 2024; 3:101294. [PMID: 39131220 PMCID: PMC11308846 DOI: 10.1016/j.jscai.2023.101294] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 12/13/2023] [Accepted: 12/27/2023] [Indexed: 08/13/2024]
Abstract
Background Post-transcatheter aortic valve replacement (TAVR), paravalvular leak (PVL) is a quality metric associated with worse clinical outcomes. Transcatheter heart valve (THV) sizing is based primarily on the systolic annular size without regard to the left ventricular outflow tract (LVOT), which also lies within the THV landing zone. We hypothesized that LVOT size relative to the annulus is associated with post-TAVR PVL. Methods Data from consecutive patients undergoing TAVR in a single high-volume center from January 2018 to March 2019 were used. Pre-TAVR data from multidetector computed tomography (MDCT) were collected. Relative LVOT area was defined as LVOT area/annular area during systole. Logistic regression analysis was used to evaluate association with post-TAVR mild or greater PVL by transthoracic echocardiography before discharge. Results Among 293 patients (median age, 81.1 years; female, 49.5%; White, 88.0%), 81.6% received SAPIEN 3 and 18.4% received CoreValve THV models. Aortic valve morphology was bicuspid in 10.9% of patients. Prevalence of mild or greater PVL was 23.5% (mild in 20.1%). Relative LVOT area had a significant inverse association such that the odds of mild or greater PVL decreased significantly with every 1% increase in relative LVOT area (adjusted odds ratio, 0.96; 95% CI, 0.93-0.98; P = .002). There was no interaction between the type of implanted valve and the relative LVOT area. Patients in the highest relative LVOT tertile had significantly lower odds of mild or greater PVL (adjusted odds ratio, 0.42; 95% CI, 0.21-0.87; P = .018 vs first tertile). Conclusions In patients undergoing TAVR with the newer generation of THV (SAPIEN 3 and CoreValve models), a relatively narrower LVOT area vs annular area was independently associated with increased odds of mild or greater PVL before discharge.
Collapse
Affiliation(s)
- Kartik Gupta
- Division of Cardiovascular Diseases, Henry Ford Health, Detroit, Michigan
| | - Pedro Villablanca
- Center for Structural Heart Disease, Henry Ford Health, Detroit, Michigan
| | | | - Brian O’Neill
- Center for Structural Heart Disease, Henry Ford Health, Detroit, Michigan
| | - William W. O’Neill
- Center for Structural Heart Disease, Henry Ford Health, Detroit, Michigan
| | - Dee Dee Wang
- Center for Structural Heart Disease, Henry Ford Health, Detroit, Michigan
| | - Jonathan X. Fang
- Center for Structural Heart Disease, Henry Ford Health, Detroit, Michigan
| | - Gennaro Giustino
- Center for Structural Heart Disease, Henry Ford Health, Detroit, Michigan
| | - Tiberio Frisoli
- Center for Structural Heart Disease, Henry Ford Health, Detroit, Michigan
| | - James C. Lee
- Center for Structural Heart Disease, Henry Ford Health, Detroit, Michigan
| |
Collapse
|
2
|
Mao Y, Liu Y, Ma Y, Zhai M, Li L, Jin P, Yang J. Feasibility of 3-dimensional printed models in simulated training and teaching of transcatheter aortic valve replacement. Open Med (Wars) 2024; 19:20240909. [PMID: 38463517 PMCID: PMC10921447 DOI: 10.1515/med-2024-0909] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2023] [Revised: 11/24/2023] [Accepted: 01/14/2024] [Indexed: 03/12/2024] Open
Abstract
In the study of TAVR, 3-dimensional (3D) printed aortic root models and pulsatile simulators were used for simulation training and teaching before procedures. The study was carried out in the following three parts: (1) experts were selected and equally divided into the 3D-printed simulation group and the non-3D-printed simulation group to conduct four times of TAVR, respectively; (2) another 10 experts and 10 young proceduralists were selected to accomplish three times of TAVR simulations; (3) overall, all the doctors were organized to complete a specific questionnaire, to evaluate the training and teaching effect of 3D printed simulations. For the 3D-printed simulation group, six proceduralists had a less crossing-valve time (8.3 ± 2.1 min vs 11.8 ± 2.7 min, P < 0.001) and total operation time (102.7 ± 15.3 min vs 137.7 ± 15.4 min, P < 0.001). In addition, the results showed that the median crossing-valve time and the total time required were significantly reduced in both the expert group and the young proceduralist group (all P<0.001). The results of the questionnaire showed that 3D-printed simulation training could enhance the understanding of anatomical structure and improve technical skills. Overall, cardiovascular 3D printing may play an important role in assisting TAVR, which can shorten the operation time and reduce potential complications.
Collapse
Affiliation(s)
- Yu Mao
- Department of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi'an, 710032, Shaanxi, China
| | - Yang Liu
- Department of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi'an, 710032, Shaanxi, China
| | - Yanyan Ma
- Department of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi'an, 710032, Shaanxi, China
| | - Mengen Zhai
- Department of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi'an, 710032, Shaanxi, China
| | - Lanlan Li
- Department of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi'an, 710032, Shaanxi, China
| | - Ping Jin
- Department of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi'an, 710032, Shaanxi, China
| | - Jian Yang
- Department of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, 127 Changle West Road, Xi'an, 710032, Shaanxi, China
| |
Collapse
|
3
|
Kalra A, Das R, Alkhalil M, Dykun I, Candreva A, Jarral O, Rehman SM, Majmundar M, Patel KN, Rodes-Cabau J, Reardon MJ, Puri R. Bicuspid Aortic Valve Disease: Classifications, Treatments, and Emerging Transcatheter Paradigms. STRUCTURAL HEART : THE JOURNAL OF THE HEART TEAM 2024; 8:100227. [PMID: 38283572 PMCID: PMC10818151 DOI: 10.1016/j.shj.2023.100227] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Revised: 09/02/2023] [Accepted: 09/14/2023] [Indexed: 01/30/2024]
Abstract
Bicuspid aortic valve (BAV) is a common congenital valvular malformation, which may lead to early aortic valve disease and bicuspid-associated aortopathy. A novel BAV classification system was recently proposed to coincide with transcatheter aortic valve replacement being increasingly considered in younger patients with symptomatic BAV, with good clinical results, yet without randomized trial evidence. Procedural technique, along with clinical outcomes, have considerably improved in BAV patients compared with tricuspid aortic stenosis patients undergoing transcatheter aortic valve replacement. The present review summarizes the novel BAV classification systems and examines contemporary surgical and transcatheter approaches.
Collapse
Affiliation(s)
- Ankur Kalra
- Department of Cardiology, Franciscan Health, Lafayette, Indiana, USA
| | - Rajiv Das
- Department of Cardiothoracic Services, Freeman Hospital, Newcastle-upon-Tyne, UK
| | - Mohammad Alkhalil
- Department of Cardiothoracic Services, Freeman Hospital, Newcastle-upon-Tyne, UK
| | - Iryna Dykun
- Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Alessandro Candreva
- Department of Cardiology, University Heart Centre, University Hospital Zurich, Zurich, Switzerland
| | - Omar Jarral
- Department of Cardiothoracic Surgery, St. Thomas Hospital, London, UK
| | - Syed M. Rehman
- Department of Cardiothoracic Surgery, OLV Hospital, Aalst, Belgium
| | - Monil Majmundar
- Department of Cardiology, University of Kansas Medical Center, Kansas City, Kansas, USA
| | - Kunal N. Patel
- Department of Cardiology, West Virginia University Hospital, Morgantown, West Virginia, USA
| | - Josep Rodes-Cabau
- Department of Interventional Cardiology, Quebec Heart & Lung Institute, Quebec City, Canada
| | - Michael J. Reardon
- Department of Cardiothoracic Surgery, Houston Methodist Hospital, Houston, Texas, USA
| | - Rishi Puri
- Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA
| |
Collapse
|
4
|
Massie C, Parent M, Berthelot-Richer M, Kouz R, Palisaitis D, Le V, Poulin F. Automated and semi-automated 3D echocardiographic software for aortic annulus sizing in transcatheter aortic valve implantation helps bridge the gap between expert and novice operators. Int J Cardiovasc Imaging 2023; 39:1707-1717. [PMID: 37572176 PMCID: PMC10520092 DOI: 10.1007/s10554-023-02885-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Accepted: 05/24/2023] [Indexed: 08/14/2023]
Abstract
3D-transesophageal echocardiography (3D-TEE) is an alternative to multidetector row computed tomography (MDCT) for aortic annulus (AoA) sizing in preparation for Transcatheter aortic valve implantation (TAVI). We aim to evaluate how the fully automated (auto) and semi-automated (SA) TEE methods perform compared to conventional manual TEE method and the gold standard MDCT for annulus sizing both in expert and novice operators. In this prospective cohort study, eighty-nine patients with severe aortic stenosis underwent multimodality imaging with 3D-TEE and MDCT. Annular measurements were collected by expert echocardiographers using 3D auto, SA and manual methods and compared to MDCT. A novice in the field of echocardiography retrospectively measured the AoA for all patients using the same methods. TEE measurements, independently of the method used, had good to very good agreement to MDCT. They significantly underestimated aortic annular area and circumference vs. MDCT with the auto method underestimating it the most and the manual method the least (6.5% and 1.3% respectively for area and circumference). For experts, the manual TEE method offered the least systematic bias while the SA method had narrower limits of agreement (LOA). For the novice operator, SA method provided the least bias and narrower LOA vs. MDCT. There is good agreement between novice and experts for all 3 TEE methods but better agreement with auto and SA methods as opposed to manual one. Our study supports the use of 3D-TEE as a complementary method to MDCT for aortic annular sizing. The newer auto and SA software, that requires minimal operator intervention, is an easy to use, reliable and reproducible tool for aortic annulus sizing for experienced operators, and especially less experienced ones.
Collapse
Affiliation(s)
- Charles Massie
- Hôpital du Sacré-Cœur de Montréal, 5400 Boul Gouin O, Montreal, QC, H4J 1C5, Canada
| | - Martine Parent
- Hôpital du Sacré-Cœur de Montréal, 5400 Boul Gouin O, Montreal, QC, H4J 1C5, Canada
| | - Maxime Berthelot-Richer
- Hôpital du Sacré-Cœur de Montréal, 5400 Boul Gouin O, Montreal, QC, H4J 1C5, Canada
- Hôtel Dieu de Québec, Quebec, QC, Canada
| | - Rémi Kouz
- Hôpital du Sacré-Cœur de Montréal, 5400 Boul Gouin O, Montreal, QC, H4J 1C5, Canada
| | - Donald Palisaitis
- Hôpital du Sacré-Cœur de Montréal, 5400 Boul Gouin O, Montreal, QC, H4J 1C5, Canada
| | - Viet Le
- Hôpital du Sacré-Cœur de Montréal, 5400 Boul Gouin O, Montreal, QC, H4J 1C5, Canada
| | - Frédéric Poulin
- Hôpital du Sacré-Cœur de Montréal, 5400 Boul Gouin O, Montreal, QC, H4J 1C5, Canada.
| |
Collapse
|
5
|
Zhu Z, Xiong T, Chen M. Comparison of patients with bicuspid and tricuspid aortic valve in transcatheter aortic valve implantation. Expert Rev Med Devices 2023; 20:209-220. [PMID: 36815427 DOI: 10.1080/17434440.2023.2184686] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/24/2023]
Abstract
BACKGROUND Transcatheter aortic valve implantation (TAVI) has emerged as a safe and effective alternative to surgery for aortic stenosis (AS). However, there are still differences in the procedural process and outcome of bicuspid aortic valve (BAV) treated with TAVI compared with tricuspid aortic valve. AREAS COVERED This review paper aims to summarize the main characteristics and clinical evidence of TAVI in patients with bicuspid and tricuspid aortic valves and compare the outcomes of TAVI procedure. EXPERT OPINION The use of TAVI in patients with BAV has shown similar clinical outcomes compared with tricuspid aortic valve. The efficacy of TAVI for challenging BAV anatomies remains a concern due to the lack of randomized trials. Detailed preprocedural planning is of great importance in low-surgical-risk BAV patients. A better understanding of which subtypes of BAV anatomy are at greater risk for adverse outcomes can potentially benefit the selection of TAVI or open-heart surgery in low surgical risk AS patients.
Collapse
Affiliation(s)
- Zhongkai Zhu
- Department of Cardiology, West China Hospital, Sichuan University, Chengdu, China
| | - Tianyuan Xiong
- Department of Cardiology, West China Hospital, Sichuan University, Chengdu, China
| | - Mao Chen
- Department of Cardiology, West China Hospital, Sichuan University, Chengdu, China
| |
Collapse
|
6
|
Baggio S, Pagnesi M, Kim WK, Scotti A, Barbanti M, Costa G, Adamo M, Kornowski R, Vaknin Assa H, Estévez-Loureiro R, Cedeño RA, De Marco F, Casenghi M, Toggweiler S, Veulemans V, Mylotte D, Lunardi M, Regazzoli D, Reimers B, Sondergaard L, Vanhaverbeke M, Nuyens P, Maffeo D, Buono A, Saccocci M, Giannini F, Di Ienno L, Ferlini M, Lanzillo G, Ielasi A, Schofer J, Brinkmann C, Van Der Heyden J, Buysschaert I, Eitan A, Wolf A, Adamaszek MM, Colombo A, Latib A, Mangieri A. Comparison of transcatheter aortic valve replacement with the ACURATE neo2 versus Evolut PRO/PRO+ devices. EUROINTERVENTION 2023; 18:977-986. [PMID: 36093795 PMCID: PMC9853030 DOI: 10.4244/eij-d-22-00498] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Accepted: 07/25/2022] [Indexed: 01/21/2023]
Abstract
BACKGROUND The ACURATE neo2 (NEO2) and Evolut PRO/PRO+ (PRO) bioprostheses are new-generation self-expanding valves developed for transcatheter aortic valve replacement (TAVR). AIMS We sought to compare the performance of the ACURATE neo2 and Evolut PRO/PRO+ devices. METHODS The NEOPRO-2 registry retrospectively included patients who underwent TAVR for severe aortic stenosis with either the NEO2 or PRO devices between August 2017 and December 2021 at 20 centres. In-hospital and 30-day Valve Academic Research Consortium (VARC)-3 defined outcomes were evaluated. Propensity score (PS) matching and binary logistic regression were performed to adjust the treatment effect for PS quintiles. A subgroup analysis assessed the impact of aortic valve calcification. RESULTS A total of 2,175 patients (NEO2: n=763; PRO: n=1,412) were included. The mean age was 82±6.2 years and the mean Society of Thoracic Surgeons score was 4.2%. Periprocedural complications were low, and both groups achieved high rates of technical success (93.1% vs 94.1%; p=0.361) and predischarge intended valve performance (96.0% vs 94.1%; p=0.056), both in the unmatched and matched analysis (452 pairs). Device success at 30 days was comparable (84.3% vs 83.6%; p=0.688), regardless of aortic valve calcification severity (p>0.05 for interaction). A suggestion for higher VARC-3 early safety in the NEO2 group was mainly driven by reduced rates of new permanent pacemaker implantation (7.7% vs 15.6%; p<0.001). CONCLUSIONS This retrospective analysis reports a similar short-term performance of the ACURATE neo2 platform compared with the new-generation Evolut PRO/PRO+ devices. Randomised studies are needed to confirm our exploratory findings.
Collapse
Affiliation(s)
- Sara Baggio
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Milan, Italy and Cardio Center, Humanitas Research Hospital IRCCS, Rozzano, Milan, Italy
| | - Matteo Pagnesi
- Cardiothoracic Department, ASST Spedali Civili di Brescia, University of Brescia, Brescia, Italy and Department of Medical Surgical Specialties, Radiological Sciences, and Public Health, University of Brescia, Brescia, Italy
| | - Won-Keun Kim
- Kerckhoff Heart and Thorax Center, Bad Nauheim, Germany
| | - Andrea Scotti
- Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY, USA
| | - Marco Barbanti
- Division of Cardiology, A.O.U. Policlinico "G. Rodolico-San Marco", Catania, Italy
| | - Giuliano Costa
- Division of Cardiology, A.O.U. Policlinico "G. Rodolico-San Marco", Catania, Italy
| | - Marianna Adamo
- Cardiothoracic Department, ASST Spedali Civili di Brescia, University of Brescia, Brescia, Italy and Department of Medical Surgical Specialties, Radiological Sciences, and Public Health, University of Brescia, Brescia, Italy
| | - Ran Kornowski
- Department of Cardiology, Rabin Medical Center, Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Hana Vaknin Assa
- Department of Cardiology, Rabin Medical Center, Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Rodrigo Estévez-Loureiro
- Cardiology Department, University Hospital Alvaro Cunqueiro, Galicia Sur Health Research Institute, Vigo, Spain
| | - Robert Alarcón Cedeño
- Cardiology Department, University Hospital Alvaro Cunqueiro, Galicia Sur Health Research Institute, Vigo, Spain
| | - Federico De Marco
- Department of Clinical and Interventional Cardiology, IRCCS Policlinico San Donato, Milan, Italy
| | - Matteo Casenghi
- Department of Clinical and Interventional Cardiology, IRCCS Policlinico San Donato, Milan, Italy
| | - Stefan Toggweiler
- Department of Cardiology, Heart Center Lucerne, Luzerner Kantonsspital, Lucerne, Switzerland
| | - Verena Veulemans
- Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University, Medical Faculty, Düsseldorf, Germany
| | - Darren Mylotte
- Galway University Hospital, SAOLTA Health Care Group, and National University of Ireland, Galway, Ireland
| | - Mattia Lunardi
- Galway University Hospital, SAOLTA Health Care Group, and National University of Ireland, Galway, Ireland
| | - Damiano Regazzoli
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Milan, Italy and Cardio Center, Humanitas Research Hospital IRCCS, Rozzano, Milan, Italy
| | - Bernhard Reimers
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Milan, Italy and Cardio Center, Humanitas Research Hospital IRCCS, Rozzano, Milan, Italy
| | - Lars Sondergaard
- Department of Cardiology, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
| | - Maarten Vanhaverbeke
- Department of Cardiology, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
| | - Philippe Nuyens
- Department of Cardiology, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
| | | | | | | | - Francesco Giannini
- Interventional Cardiology Unit, GVM Care & Research, Maria Cecilia Hospital, Cotignola, Italy
| | - Luca Di Ienno
- Interventional Cardiology Unit, GVM Care & Research, Maria Cecilia Hospital, Cotignola, Italy
| | - Marco Ferlini
- Division of Cardiology, Fondazione IRCCS Policlinico San Matteo, Pavia, Italy
| | - Giuseppe Lanzillo
- Division of Cardiology, Fondazione IRCCS Policlinico San Matteo, Pavia, Italy
| | - Alfonso Ielasi
- Clinical and Interventional Cardiology Unit, Clinical Institute Saint Ambrogio, Milan, Italy
| | | | | | | | - Ian Buysschaert
- Interventional Cardiology Unit, AZ Sint-Jan Hospital, Brugge, Belgium
| | - Amnon Eitan
- Department of Cardiology, Carmel Medical Center, Haifa, Israel
| | - Alexander Wolf
- Klinik für Kardiologie, Elisabeth-Krankenhaus Essen, Essen, Germany
| | | | - Antonio Colombo
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Milan, Italy and Cardio Center, Humanitas Research Hospital IRCCS, Rozzano, Milan, Italy
| | - Azeem Latib
- Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY, USA
| | - Antonio Mangieri
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Milan, Italy and Cardio Center, Humanitas Research Hospital IRCCS, Rozzano, Milan, Italy
| |
Collapse
|
7
|
Scotti A, Baggio S, Pagnesi M, Barbanti M, Adamo M, Eitan A, Estévez-Loureiro R, Veulemans V, Toggweiler S, Mylotte D, De Marco F, Giannini F, Ferlini M, Naber CK, Buono A, Schofer J, Rottbauer W, Van Mieghem NM, Khogali S, Taramasso M, Pilgrim T, Sinning JM, Zweiker D, Montorfano M, Van der Heyden JAS, Brugaletta S, Ielasi A, Hamm CW, Vanhaverbeke M, Costa G, Massussi M, Alarcón R, Zeus T, Lunardi M, Testa L, Di Ienno L, Lanzillo G, Wolf A, Maffeo D, Ziviello F, Saccocci M, Windecker S, Sedaghat A, Schmidt A, Brouwer J, Regueiro A, Reimers B, Kim WK, Sondergaard L, Colombo A, Mangieri A, Latib A. Temporal Trends and Contemporary Outcomes After Transcatheter Aortic Valve Replacement With Evolut PRO/PRO+ Self-Expanding Valves: Insights From the NEOPRO/NEOPRO-2 Registries. Circ Cardiovasc Interv 2023; 16:e012538. [PMID: 36649387 DOI: 10.1161/circinterventions.122.012538] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
BACKGROUND In recent years, transcatheter aortic valve replacement (TAVR) techniques and technology have continuously improved. Data regarding the impact of these advancements on outcomes in large real-world settings are still limited. The aim of this study was to investigate temporal trends and assess contemporary outcomes after TAVR with Evolut PRO/PRO+ supra-annular self-expanding valves. METHODS This study included patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries who underwent transfemoral TAVR with Evolut PRO/PRO+. Procedural dates (August 2017 through November 2021) were stratified in quartiles (Q) and used to investigate temporal trends in TAVR outcomes. Predischarge, 30-day Valve Academic Research Consortium-3 defined, and 1-year outcomes were evaluated. RESULTS In total, 1616 patients from 28 centers were included. Over time, patients had lower Society of Thoracic Surgeon-Predicted Risk of Mortality score (Q1-4, 4.1% [2.8-6.3%], 3.7% [2.6-5.3%], 3.3% [2.4-4.9%], 2.9% [2.2-4.3%]; P<0.001) and more moderate or heavy valve calcification (Q1-4, 80%, 80%, 82%, 88%; P=0.038). Overall Valve Academic Research Consortium-3 technical success was 94.1%, with 30-day and 1-year all-cause mortality of 2.4% and 10%, respectively. Throughout the study period, procedures were associated with higher rates of 30-day device success (Q1-4, 81.2%, 82.2%, 82.0%, 88.0%; Cochran-Armitage P=0.023) and early safety (Q1-4, 66.8%, 67.5%, 74.0%, 77.6%; Cochran-Armitage P<0.001), with fewer permanent pacemaker implantations (Q1-4: 15.3%, 20.0%, 12.1%, 11.6%; Cochran-Armitage P=0.023) and residual mild or greater paravalvular leaks (Q1-4, 50.4%, 42.1%, 36.5%, 35.8%; Cochran-Armitage P<0.001). CONCLUSIONS TAVR with Evolut PRO/PRO+ self-expanding valve is safe and effective. Despite the treatment of heavier calcified anatomies, procedural outcomes are improving over time with less need for pacemaker implantation and less significant paravalvular leaks.
Collapse
Affiliation(s)
- Andrea Scotti
- Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY (A.S., A.L.)
| | - Sara Baggio
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele-Milan, Italy (S.B., B.R., A.C., A.M.).,IRCCS Humanitas Research Hospital, Rozzano-Milan, Italy (S.B., B.R., A.C., A.M.)
| | - Matteo Pagnesi
- Cardiothoracic Department, ASST Spedali Civili di Brescia University of Brescia, Italy (M.P., M.A., M. Massussi).,Department of Medical Surgical Specialties, Radiological Sciences, and Public Health, University of Brescia, Italy (M.P., M.A., M. Massussi)
| | - Marco Barbanti
- Department of Cardiology, C.A.S.T. Policlinico G. Rodolico, Catania, Italy (M.B., G.C.)
| | - Marianna Adamo
- Cardiothoracic Department, ASST Spedali Civili di Brescia University of Brescia, Italy (M.P., M.A., M. Massussi).,Department of Medical Surgical Specialties, Radiological Sciences, and Public Health, University of Brescia, Italy (M.P., M.A., M. Massussi)
| | - Amnon Eitan
- Department of Cardiology, Carmel Medical Center, Haifa, Israel (A.E.)
| | - Rodrigo Estévez-Loureiro
- Cardiology Department, University Hospital Alvaro Cunqueiro, Galicia Sur Health Research Institute, Vigo, Spain (R.E.-L., R.A.)
| | - Verena Veulemans
- Division of Cardiology, Pulmonology and Vascular Medicine, University Hospital Düsseldorf, Germany (V.V., T.Z.)
| | - Stefan Toggweiler
- Heart Center Lucerne, Department of Cardiology, Luzerner Kantonsspital, Lucerne, Switzerland (S.T.)
| | - Darren Mylotte
- Department of Cardiology, Galway University Hospitals, Ireland (D.M., M.L.)
| | | | - Francesco Giannini
- Interventional Cardiology Unit, GVM Care and Research, Maria Cecilia Hospital, Cotignola, Italy (F.G., L.D.I.)
| | - Marco Ferlini
- Division of Cardiology, Fondazione IRCCS Policlinico San Matteo, Pavia, Italy (M.F., G.L.)
| | - Christoph K Naber
- Contilia Heart and Vascular Centre, Elisabeth-Krankenhaus Essen, Germany (C.K.N., A.W.)
| | - Andrea Buono
- Interventional Cardiology Unit, Fondazione Poliambulanza, Brescia, Italy (A.B., D.M.)
| | - Joachim Schofer
- Department for Percutaneous Treatment of Structural Heart Disease, Albertinen Heart Center, Hamburg, Germany (J.S.).,MVZ Department Structural Heart Disease, Asklepios St Georg Clinic, Hamburg, Germany (J.S.)
| | - Wolfgang Rottbauer
- Department of Internal Medicine II, University Hospital Ulm, Germany (W.R., S.W.)
| | - Nicolas M Van Mieghem
- Department of Cardiology, Thoraxcenter, Erasmus University Medical Center, Rotterdam, the Netherlands (N.M.V.M., F.Z.)
| | - Saib Khogali
- Heart and Lung Center, New Cross Hospital, Wolverhampton, UK (S.K.)
| | - Maurizio Taramasso
- Division of Cardiothoracic Surgery, HerzZentrum Hirslanden Zürich, Switzerland (M.T., M.S.)
| | - Thomas Pilgrim
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Switzerland (T.P.)
| | - Jan-Malte Sinning
- Department of Cardiology, Heart Center Bonn, University Hospital Bonn, Germany (J.-M.S., A. Sedaghat)
| | - David Zweiker
- Division of Cardiology, Medical University of Graz, Austria (D.Z., A. Schmidt)
| | - Matteo Montorfano
- Interventional Cardiology Unit, San Raffaele Scientific Institute, Milan, Italy (M. Montorfano)
| | - Jan A S Van der Heyden
- Department of Cardiology, St Antonius Hospital, Nieuwegein, the Netherlands (J.A.S.V.d.H., J.B.).,Interventional Cardiology Unit, AZ Sint-Jan Hospital, Bruges, Belgium (J.A.S.V.d.H.)
| | - Salvatore Brugaletta
- Clinic Cardiovascular Institute, Hospital Clinic, Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), University of Barcelona, Spain (S.B., A.R.)
| | - Alfonso Ielasi
- Clinical and Interventional Cardiology Unit, Istituto Clinico Sant'Ambrogio, Milan, Italy (A.I.)
| | - Christian W Hamm
- Department of Cardiology and Cardiac Surgery, Kerckhoff Heart Center, Bad Nauheim, Germany (C.W.H., W.-K.K.)
| | - Maarten Vanhaverbeke
- The Heart Centre, Rigshospitalet, Copenhagen University Hospital, Denmark (M.V., L.S.)
| | - Giuliano Costa
- Department of Cardiology, C.A.S.T. Policlinico G. Rodolico, Catania, Italy (M.B., G.C.)
| | - Mauro Massussi
- Cardiothoracic Department, ASST Spedali Civili di Brescia University of Brescia, Italy (M.P., M.A., M. Massussi).,Department of Medical Surgical Specialties, Radiological Sciences, and Public Health, University of Brescia, Italy (M.P., M.A., M. Massussi)
| | - Robert Alarcón
- Cardiology Department, University Hospital Alvaro Cunqueiro, Galicia Sur Health Research Institute, Vigo, Spain (R.E.-L., R.A.)
| | - Tobias Zeus
- Division of Cardiology, Pulmonology and Vascular Medicine, University Hospital Düsseldorf, Germany (V.V., T.Z.)
| | - Mattia Lunardi
- Department of Cardiology, Galway University Hospitals, Ireland (D.M., M.L.)
| | - Luca Testa
- Department of Clinical and Interventional Cardiology, IRCCS Policlinico San Donato, Milan, Italy (L.T.)
| | - Luca Di Ienno
- Interventional Cardiology Unit, GVM Care and Research, Maria Cecilia Hospital, Cotignola, Italy (F.G., L.D.I.)
| | - Giuseppe Lanzillo
- Division of Cardiology, Fondazione IRCCS Policlinico San Matteo, Pavia, Italy (M.F., G.L.)
| | - Alexander Wolf
- Contilia Heart and Vascular Centre, Elisabeth-Krankenhaus Essen, Germany (C.K.N., A.W.)
| | - Diego Maffeo
- Interventional Cardiology Unit, Fondazione Poliambulanza, Brescia, Italy (A.B., D.M.)
| | - Francesca Ziviello
- Department of Cardiology, Thoraxcenter, Erasmus University Medical Center, Rotterdam, the Netherlands (N.M.V.M., F.Z.)
| | - Matteo Saccocci
- Division of Cardiothoracic Surgery, HerzZentrum Hirslanden Zürich, Switzerland (M.T., M.S.)
| | - Stephan Windecker
- Department of Internal Medicine II, University Hospital Ulm, Germany (W.R., S.W.)
| | - Alexander Sedaghat
- Department of Cardiology, Heart Center Bonn, University Hospital Bonn, Germany (J.-M.S., A. Sedaghat)
| | - Albrecht Schmidt
- Division of Cardiology, Medical University of Graz, Austria (D.Z., A. Schmidt)
| | - Jorn Brouwer
- Department of Cardiology, St Antonius Hospital, Nieuwegein, the Netherlands (J.A.S.V.d.H., J.B.)
| | - Ander Regueiro
- Clinic Cardiovascular Institute, Hospital Clinic, Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), University of Barcelona, Spain (S.B., A.R.)
| | - Bernhard Reimers
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele-Milan, Italy (S.B., B.R., A.C., A.M.).,IRCCS Humanitas Research Hospital, Rozzano-Milan, Italy (S.B., B.R., A.C., A.M.)
| | - Won-Keun Kim
- Department of Cardiology and Cardiac Surgery, Kerckhoff Heart Center, Bad Nauheim, Germany (C.W.H., W.-K.K.)
| | - Lars Sondergaard
- The Heart Centre, Rigshospitalet, Copenhagen University Hospital, Denmark (M.V., L.S.)
| | - Antonio Colombo
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele-Milan, Italy (S.B., B.R., A.C., A.M.).,IRCCS Humanitas Research Hospital, Rozzano-Milan, Italy (S.B., B.R., A.C., A.M.)
| | - Antonio Mangieri
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele-Milan, Italy (S.B., B.R., A.C., A.M.).,IRCCS Humanitas Research Hospital, Rozzano-Milan, Italy (S.B., B.R., A.C., A.M.)
| | - Azeem Latib
- Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY (A.S., A.L.)
| | | |
Collapse
|
8
|
Ma Y, Mao Y, Zhu G, Yang J. Application of cardiovascular 3-dimensional printing in Transcatheter aortic valve replacement. CELL REGENERATION (LONDON, ENGLAND) 2022; 11:35. [PMID: 36121512 PMCID: PMC9485371 DOI: 10.1186/s13619-022-00129-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Accepted: 07/05/2022] [Indexed: 11/10/2022]
Abstract
Transcatheter aortic valve replacement (TAVR) has been performed for nearly 20 years, with reliable safety and efficacy in moderate- to high-risk patients with aortic stenosis or regurgitation, with the advantage of less trauma and better prognosis than traditional open surgery. However, because surgeons have not been able to obtain a full view of the aortic root, 3-dimensional printing has been used to reconstruct the aortic root so that they could clearly and intuitively understand the specific anatomical structure. In addition, the 3D printed model has been used for the in vitro simulation of the planned procedures to predict the potential complications of TAVR, the goal being to provide guidance to reasonably plan the procedure to achieve the best outcome. Postprocedural 3D printing can be used to understand the depth, shape, and distribution of the stent. Cardiovascular 3D printing has achieved remarkable results in TAVR and has a great potential.
Collapse
Affiliation(s)
- Yanyan Ma
- Department of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, 127 Changle West Road, Xi'an, 710032, Shaanxi, China
| | - Yu Mao
- Department of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, 127 Changle West Road, Xi'an, 710032, Shaanxi, China
| | - Guangyu Zhu
- School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an, China
| | - Jian Yang
- Department of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, 127 Changle West Road, Xi'an, 710032, Shaanxi, China.
| |
Collapse
|
9
|
Chiarito M, Spirito A, Nicolas J, Selberg A, Stefanini G, Colombo A, Reimers B, Kini A, Sharma SK, Dangas GD, Mehran R. Evolving Devices and Material in Transcatheter Aortic Valve Replacement: What to Use and for Whom. J Clin Med 2022; 11:jcm11154445. [PMID: 35956061 PMCID: PMC9369546 DOI: 10.3390/jcm11154445] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2022] [Revised: 07/21/2022] [Accepted: 07/26/2022] [Indexed: 02/04/2023] Open
Abstract
Transcatheter aortic valve replacement (TAVR) has revolutionized the treatment of aortic stenosis, providing a viable alternative to surgical aortic valve replacement (SAVR) for patients deemed to be at prohibitive surgical risk, but also for selected patients at intermediate or low surgical risk. Nonetheless, there still exist uncertainties regarding the optimal management of patients undergoing TAVR. The selection of the optimal bioprosthetic valve for each patient represents one of the most challenging dilemmas for clinicians, given the large number of currently available devices. Limited follow-up data from landmark clinical trials comparing TAVR with SAVR, coupled with the typically elderly and frail population of patients undergoing TAVR, has led to inconclusive data on valve durability. Recommendations about the use of one device over another in given each patient’s clinical and procedural characteristics are largely based on expert consensus. This review aims to evaluate the available evidence on the performance of different devices in the presence of specific clinical and anatomic features, with a focus on patient, procedural, and device features that have demonstrated a relevant impact on the risk of poor hemodynamic valve performance and adverse clinical events.
Collapse
Affiliation(s)
- Mauro Chiarito
- The Zena and Michael A. Wiener Cardiovascular Institute, Icahn School of Medicine at Mount Sinai, One Gustave L. Levy Place, New York, NY 10029, USA; (M.C.); (J.N.); (A.S.); (A.S.); (A.K.); (S.K.S.); (G.D.D.)
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, 20090 Pieve Emanuele, Italy; (G.S.); (A.C.); (B.R.)
| | - Alessandro Spirito
- The Zena and Michael A. Wiener Cardiovascular Institute, Icahn School of Medicine at Mount Sinai, One Gustave L. Levy Place, New York, NY 10029, USA; (M.C.); (J.N.); (A.S.); (A.S.); (A.K.); (S.K.S.); (G.D.D.)
| | - Johny Nicolas
- The Zena and Michael A. Wiener Cardiovascular Institute, Icahn School of Medicine at Mount Sinai, One Gustave L. Levy Place, New York, NY 10029, USA; (M.C.); (J.N.); (A.S.); (A.S.); (A.K.); (S.K.S.); (G.D.D.)
| | - Alexandra Selberg
- The Zena and Michael A. Wiener Cardiovascular Institute, Icahn School of Medicine at Mount Sinai, One Gustave L. Levy Place, New York, NY 10029, USA; (M.C.); (J.N.); (A.S.); (A.S.); (A.K.); (S.K.S.); (G.D.D.)
| | - Giulio Stefanini
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, 20090 Pieve Emanuele, Italy; (G.S.); (A.C.); (B.R.)
- Istituti di Ricovero e Cura a Carattere Scientifico, Humanitas Research Hospital, Via Alessandro Manzoni, 56, 20089 Rozzano, Italy
| | - Antonio Colombo
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, 20090 Pieve Emanuele, Italy; (G.S.); (A.C.); (B.R.)
- Istituti di Ricovero e Cura a Carattere Scientifico, Humanitas Research Hospital, Via Alessandro Manzoni, 56, 20089 Rozzano, Italy
| | - Bernhard Reimers
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, 20090 Pieve Emanuele, Italy; (G.S.); (A.C.); (B.R.)
- Istituti di Ricovero e Cura a Carattere Scientifico, Humanitas Research Hospital, Via Alessandro Manzoni, 56, 20089 Rozzano, Italy
| | - Annapoorna Kini
- The Zena and Michael A. Wiener Cardiovascular Institute, Icahn School of Medicine at Mount Sinai, One Gustave L. Levy Place, New York, NY 10029, USA; (M.C.); (J.N.); (A.S.); (A.S.); (A.K.); (S.K.S.); (G.D.D.)
| | - Samin K. Sharma
- The Zena and Michael A. Wiener Cardiovascular Institute, Icahn School of Medicine at Mount Sinai, One Gustave L. Levy Place, New York, NY 10029, USA; (M.C.); (J.N.); (A.S.); (A.S.); (A.K.); (S.K.S.); (G.D.D.)
| | - George D. Dangas
- The Zena and Michael A. Wiener Cardiovascular Institute, Icahn School of Medicine at Mount Sinai, One Gustave L. Levy Place, New York, NY 10029, USA; (M.C.); (J.N.); (A.S.); (A.S.); (A.K.); (S.K.S.); (G.D.D.)
| | - Roxana Mehran
- The Zena and Michael A. Wiener Cardiovascular Institute, Icahn School of Medicine at Mount Sinai, One Gustave L. Levy Place, New York, NY 10029, USA; (M.C.); (J.N.); (A.S.); (A.S.); (A.K.); (S.K.S.); (G.D.D.)
- Correspondence: ; Tel.: +1-(212)-659-9649; Fax: +1-(646)-537-8547
| |
Collapse
|
10
|
The Effect of TAVR on Left Ventricular and Left Atrial Mechanics in Patients with Aortic Stenosis. J Cardiovasc Dev Dis 2022; 9:jcdd9020035. [PMID: 35200690 PMCID: PMC8877352 DOI: 10.3390/jcdd9020035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Revised: 01/13/2022] [Accepted: 01/14/2022] [Indexed: 11/25/2022] Open
Abstract
Background. Measures of adverse cardiac remodeling, left ventricular global longitudinal strain (LVGLS) and left atrial (LA) phasic function, are predictive of cardiac events in patients with severe aortic stenosis (AS). How these parameters of cardiac function change following TAVR requires further investigation. Methods. A number of 109 consecutive patients with symptomatic severe AS who were seen in the heart valve clinic between 2014 and 2019 for TAVR were included. All patients underwent echocardiographic assessment prior to and 30 days following TAVR, with LVGLS and LA phasic function evaluation using 2D speckle-tracking echocardiography. Heart failure hospitalization, and death were assessed at 12 months. Results. The mean age of the study cohort was 81 ± 7.3 years. Following TAVR, there was a significant reduction in NYHA class III/IV symptoms [89 (82%) vs. 12 (11%), p < 0.01], and median mean aortic valve gradient [44 mmHg (16) vs. 9 mmHg (7), p < 0.01]. There was no significant change in the median LVEF [62% (13) vs. 62% (6.0), p = 0.2]; however, the LVGLS significantly increased following TAVR [15 ± 3.5% vs. 18 ± 3.3%, p < 0.01]. The median LA reservoir, conduit and contractile function significantly improved following TAVR [22.0% (14.0) vs. 18.0% (14.0) p < 0.01, 8.9% (5.4) vs. 7.8% (4.8) p < 0.01, 12% (11.0) vs. 9.6% (11.0) p < 0.01, respectively]. The incidence of death or heart failure hospitalization at 12 months was low, and occurred in eight patients (7.3%). Conclusions. TAVR results in significant short-term reverse LV and LA remodeling, as shown by improvement in LV GLS and all three components of LA phasic function, despite no change in the LVEF. The findings indicate the possible utility of strain imaging for the assessment of global LV and LA function following TAVR.
Collapse
|
11
|
Petri N, Lengenfelder B, Voelker W, Nordbeck P. Interventional closure of aortomitral perforation after TAVR: A case report. Catheter Cardiovasc Interv 2021; 98:E483-E485. [PMID: 33600044 DOI: 10.1002/ccd.29561] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/26/2020] [Revised: 01/24/2021] [Accepted: 02/06/2021] [Indexed: 11/05/2022]
Abstract
Despite TAVR emerging as the gold standard for a broad spectrum of patients, it is associated with serious complications. In this report we present a case, where a TAVR procedure led to a perforation at the aortomitral continuity, discuss the risk factors for the occurrence of perforations and how we decided to treat the patient.
Collapse
Affiliation(s)
- Nils Petri
- Department of Internal Medicine I, University Hospital of Würzburg, Würzburg, Germany
| | - Björn Lengenfelder
- Department of Internal Medicine I, University Hospital of Würzburg, Würzburg, Germany
| | - Wolfram Voelker
- Department of Internal Medicine I, University Hospital of Würzburg, Würzburg, Germany
| | - Peter Nordbeck
- Department of Internal Medicine I, University Hospital of Würzburg, Würzburg, Germany
| |
Collapse
|