1
|
|
2
|
Grabolle M, Kapusta P, Nann T, Shu X, Ziegler J, Resch-Genger U. Fluorescence Lifetime Multiplexing with Nanocrystals and Organic Labels. Anal Chem 2009; 81:7807-13. [DOI: 10.1021/ac900934a] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Affiliation(s)
- Markus Grabolle
- BAM Federal Institute for Materials Research and Testing, Richard-Willstaetter-Strasse 11, 12489 Berlin, Germany, PicoQuant GmbH, Rudower Chaussee 29, 12489 Berlin, Germany, and School of Chemistry, University of East Anglia (UEA), Norwich NR4 7TJ, U.K
| | - Peter Kapusta
- BAM Federal Institute for Materials Research and Testing, Richard-Willstaetter-Strasse 11, 12489 Berlin, Germany, PicoQuant GmbH, Rudower Chaussee 29, 12489 Berlin, Germany, and School of Chemistry, University of East Anglia (UEA), Norwich NR4 7TJ, U.K
| | - Thomas Nann
- BAM Federal Institute for Materials Research and Testing, Richard-Willstaetter-Strasse 11, 12489 Berlin, Germany, PicoQuant GmbH, Rudower Chaussee 29, 12489 Berlin, Germany, and School of Chemistry, University of East Anglia (UEA), Norwich NR4 7TJ, U.K
| | - Xu Shu
- BAM Federal Institute for Materials Research and Testing, Richard-Willstaetter-Strasse 11, 12489 Berlin, Germany, PicoQuant GmbH, Rudower Chaussee 29, 12489 Berlin, Germany, and School of Chemistry, University of East Anglia (UEA), Norwich NR4 7TJ, U.K
| | - Jan Ziegler
- BAM Federal Institute for Materials Research and Testing, Richard-Willstaetter-Strasse 11, 12489 Berlin, Germany, PicoQuant GmbH, Rudower Chaussee 29, 12489 Berlin, Germany, and School of Chemistry, University of East Anglia (UEA), Norwich NR4 7TJ, U.K
| | - Ute Resch-Genger
- BAM Federal Institute for Materials Research and Testing, Richard-Willstaetter-Strasse 11, 12489 Berlin, Germany, PicoQuant GmbH, Rudower Chaussee 29, 12489 Berlin, Germany, and School of Chemistry, University of East Anglia (UEA), Norwich NR4 7TJ, U.K
| |
Collapse
|
3
|
Hemmilá I, Mukkala VM. Time-Resolution in Fluorometry Technologies, Labels, and Applications in Bioanalytical Assays. Crit Rev Clin Lab Sci 2008. [DOI: 10.1080/20014091084254] [Citation(s) in RCA: 194] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
4
|
Llopis SD, Stryjewski W, Soper SA. Near-infrared time-resolved fluorescence lifetime determinations in poly(methylmethacrylate) microchip electrophoresis devices. Electrophoresis 2005; 25:3810-9. [PMID: 15565677 DOI: 10.1002/elps.200406054] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
High aspect-ratio microstructures were hot-embossed in polymer substrates with a molding tool fabricated using lithography/electroplating/forming (LIGA). The resulting devices were used for the electrophoretic separation of oligonucleotides labeled with near-infrared (near-IR) dyes. Near-IR time-resolved fluorescence was used as an identification method for the labeling dyes. The detection apparatus consisted of a pulsed laser diode operating at 680 nm, a single-photon avalanche diode, an integrated microscope, and a PC-board incorporating time-correlated single photon counting electronics. Investigation of the optical quality and amount of autofluorescence generated from different polymer substrates was carried out in the near-IR region for determining compatibility with time-resolved fluorescence. Our results revealed that of several poly(methylmethacrylate)(PMMA) substrates, brand Plexiglas offered minimal replication errors in the embossed features using appropriate embossing conditions with low background fluorescence contributions to the observed decay. Near-IR dye-labeled oligonucleotides were separated to determine the applicability of fluorescence lifetime discrimination between Cy5.5 (tauf = 930 ps) and IRD700 (tauf = 851 ps) labeling dyes during the microchip separation. These dyes were used to label T-fragments (thymine) of an M13mp18 ssDNA template. The DNA ladders were electrophoresed at 130 V/cm in a 4% linear polyacrylamide gel (LPA) gel matrix in a 9.5 cm long serpentine channel heated to 50 degrees C. The electropherogram revealed that the lifetimes could be accurately read well beyond 450 bases, although single-base pair resolution in the electropherogram was difficult to achieve due to potential solute-wall interactions in the polymer microdevice or the electroosmotic flow (EOF) properties of the device. The relative standard deviations secured for individual bands in the electropherogram were similar to those obtained using capillary gel electrophoresis, in spite of the lower load volume.
Collapse
Affiliation(s)
- Shawn D Llopis
- Louisiana State University, Department of Chemistry, Baton Rouge, LA 70803-1804, USA
| | | | | |
Collapse
|
5
|
Hewitt JD, McGown LB. On-the-fly fluorescence lifetime detection of humic substances in capillary electrophoresis. APPLIED SPECTROSCOPY 2003; 57:256-265. [PMID: 14658616 DOI: 10.1366/000370203321558155] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
On-the-fly fluorescence lifetime detection was investigated as a tool for studying humic substances in capillary zone electrophoresis (CZE). Humic substances are complex, heterogeneous mixtures of natural products that tend to migrate in a single, broad CZE peak. The intrinsic fluorescence lifetime of five humic substances from the International Humic Substances Society (IHSS) was monitored using excitation at 488 or 364 nm to produce intensity-lifetime electropherograms for each of the substances. Each frequency-domain lifetime measurement, collected at subsecond intervals during the CZE run, contains the equivalent of a complete decay profile. Lifetime analysis of each decay profile was used to construct a lifetime-resolved electropherogram for each lifetime component, from which the variation in relative intensity contributions of each lifetime across the broad CZE peak could be determined. Absorption spectra, fluorescence excitation-emission spectra, and lifetime profiles of batch solutions of the samples were determined as well. It was found that, whereas absorption and fluorescence spectral characteristics tended to discriminate between humic acids and fulvic acids, the batch solution lifetime profiles discriminated instead between samples from different sources, regardless of fraction. On-the-fly lifetime detection provided a more detailed view of the fluorescence decay of the samples, including greater resolution of lifetimes for two of the fulvic acids and greater discrimination among samples based on lifetime profiles across the CZE peaks.
Collapse
Affiliation(s)
- Joseph D Hewitt
- Department of Chemistry, Gross Chemical Laboratory, Box 90346, Duke University, Durham, North Carolina 27708, USA
| | | |
Collapse
|
6
|
Lassiter SJ, Stryjewski W, Legendre BL, Erdmann R, Wahl M, Wurm J, Peterson R, Middendorf L, Soper SA. Time-resolved fluorescence imaging of slab gels for lifetime base-calling in DNA sequencing applications. Anal Chem 2000; 72:5373-82. [PMID: 11080890 DOI: 10.1021/ac000744v] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
A compact time-resolved near-IR fluorescence imager was constructed to obtain lifetime and intensity images of DNA sequencing slab gels. The scanner consisted of a microscope body with f/1.2 relay optics onto which was mounted a pulsed diode laser (repetition rate 80 MHz, lasing wavelength 680 nm, average power 5 mW), filtering optics, and a large photoactive area (diameter 500 microns) single-photon avalanche diode that was actively quenched to provide a large dynamic operating range. The time-resolved data were processed using electronics configured in a conventional time-correlated single-photon-counting format with all of the counting hardware situated on a PC card resident on the computer bus. The microscope head produced a timing response of 450 ps (fwhm) in a scanning mode, allowing the measurement of subnano-second lifetimes. The time-resolved microscope head was placed in an automated DNA sequencer and translated across a 21-cm-wide gel plate in approximately 6 s (scan rate 3.5 cm/s) with an accumulation time per pixel of 10 ms. The sampling frequency was 0.17 Hz (duty cycle 0.0017), sufficient to prevent signal aliasing during the electrophoresis separation. Software (written in Visual Basic) allowed acquisition of both the intensity image and lifetime analysis of DNA bands migrating through the gel in real time. Using a dual-labeling (IRD700 and Cy5.5 labeling dyes)/two-lane sequencing strategy, we successfully read 670 bases of a control M13mp18 ssDNA template using lifetime identification. Comparison of the reconstructed sequence with the known sequence of the phage indicated the number of miscalls was only 2, producing an error rate of approximately 0.3% (identification accuracy 99.7%). The lifetimes were calculated using maximum likelihood estimators and allowed on-line determinations with high precision, even when short integration times were used to construct the decay profiles. Comparison of the lifetime base calling to a single-dye/four-lane sequencing strategy indicated similar results in terms of miscalls, but reduced insertion and deletion errors using lifetime identification methods, improving the overall read accuracy.
Collapse
Affiliation(s)
- S J Lassiter
- Department of Chemistry, Louisiana State University, Baton Rouge 70803-1804, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
7
|
Abstract
As capillary electrophoresis continues to focus on miniaturization, either through reducing column dimensions or situating entire electrophoresis systems on planar chips, advances in detection become necessary to meet the challenges posed by these electrophoresis platforms. The challenges result from the fact that miniaturization requires smaller load volumes, demanding highly sensitive detection. In addition, many times multiple targets must be analyzed simultaneously (multiplexed applications), further complicating detection. Near-infrared (NIR) fluorescence offers an attractive alternative to visible fluorescence for critical applications in capillary electrophoresis due to the impressive limits of detection that can be generated, in part resulting from the low background levels that are observed in the NIR. Advances in instrumentation and fluorogenic labels appropriate for NIR monitoring have led to a growing number of examples of the use of NIR fluorescence in capillary electrophoresis. In this review, we will cover instrumental components used to construct ultrasensitive NIR fluorescence detectors, including light sources and photon transducers. In addition, we will discuss various types of labeling dyes appropriate for NIR fluorescence and finally, we will present several applications that have used NIR fluorescence in capillary electrophoresis, especially for DNA sequencing and fragment analysis.
Collapse
Affiliation(s)
- S McWhorter
- Louisiana State University, Department of Chemistry, Baton Rouge 70803-1804, USA
| | | |
Collapse
|
8
|
Neumann M, Herten DP, Dietrich A, Wolfrum J, Sauer M. Capillary array scanner for time-resolved detection and identification of fluorescently labelled DNA fragments. J Chromatogr A 2000; 871:299-310. [PMID: 10735310 DOI: 10.1016/s0021-9673(99)00909-7] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
The first capillary array scanner for time-resolved fluorescence detection in parallel capillary electrophoresis based on semiconductor technology is described. The system consists essentially of a confocal fluorescence microscope and a x,y-microscope scanning stage. Fluorescence of the labelled probe molecules was excited using a short-pulse diode laser emitting at 640 nm with a repetition rate of 50 MHz. Using a single filter system the fluorescence decays of different labels were detected by an avalanche photodiode in combination with a PC plug-in card for time-correlated single-photon counting (TCSPC). The time-resolved fluorescence signals were analyzed and identified by a maximum likelihood estimator (MLE). The x,y-microscope scanning stage allows for discontinuous, bidirectional scanning of up to 16 capillaries in an array, resulting in longer fluorescence collection times per capillary compared to scanners working in a continuous mode. Synchronization of the alignment and measurement process were developed to allow for data acquisition without overhead. Detection limits in the subzeptomol range for different dye molecules separated in parallel capillaries have been achieved. In addition, we report on parallel time-resolved detection and separation of more than 400 bases of single base extension DNA fragments in capillary array electrophoresis. Using only semiconductor technology the presented technique represents a low-cost alternative for high throughput DNA sequencing in parallel capillaries.
Collapse
Affiliation(s)
- M Neumann
- Physikalisch-Chemisches-Institut, Universität Heidelberg, Germany.
| | | | | | | | | |
Collapse
|
9
|
Lieberwirth U, Arden-Jacob J, Drexhage KH, Herten DP, Müller R, Neumann M, Schulz A, Siebert S, Sagner G, Klingel S, Sauer M, Wolfrum J. Multiplex dye DNA sequencing in capillary gel electrophoresis by diode laser-based time-resolved fluorescence detection. Anal Chem 1998; 70:4771-9. [PMID: 9844573 DOI: 10.1021/ac980230k] [Citation(s) in RCA: 97] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
A new one-lane, four-dye DNA sequencing method was developed which is based on time-resolved detection and identification of fluorescently labeled primers. For fluorescent labels, we used two newly synthesized rhodamine derivatives (MR200-1, JA169), a new oxazine derivative (JA242), and a commercially available cyanine dye (CY5). The dye fluorescence was excited by a pulsed diode laser emitting at 630 nm. The fluorescence decay was detected by an avalanche photodiode using a single-filter system. The dyes used here, so-called multiplex dyes, can be distinguished and identified via their fluorescence decay patterns. The DNA fragments were labeled at the primer using linkers of various lengths and positions. For separation of the enzymatically generated DNA fragments, capillary gel electrophoresis (CGE) with a 5% linear polyacrylamide gel was employed. On covalent attachment to oligonucleotides, the dyes exhibit fluorescence decay times of 3.7 (MR200-1), 2.9 (JA169), 2.4 (JA242), and 1.6 ns (CY5) measured during CGE. The CGE mobility of the labeled DNA fragments could be controlled and nearly equalized by the coupling position and the linker length. First, time-resolved, one-lane, four-dye DNA sequencing runs in CGE are presented. The sequence information of 660 bp was determined with a probability of correct classification of > 90%. This result was obtained directly from the raw data without any of the mobility corrections that are necessary with other methods.
Collapse
Affiliation(s)
- U Lieberwirth
- Physikalisch-Chemisches Institut, Universität Heidelberg, Germany
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Soper SA, Warner IM, McGown LB. Molecular Fluorescence, Phosphorescence, and Chemiluminescence Spectrometry. Anal Chem 1998. [DOI: 10.1021/a1980019y] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Steven A. Soper
- Department of Chemistry, Louisiana State University, Baton Rouge, Louisiana 70803, and Department of Chemistry, Duke University, Box 90346, Durham, North Carolina 27708-0346
| | - Isiah M. Warner
- Department of Chemistry, Louisiana State University, Baton Rouge, Louisiana 70803, and Department of Chemistry, Duke University, Box 90346, Durham, North Carolina 27708-0346
| | - Linda B. McGown
- Department of Chemistry, Louisiana State University, Baton Rouge, Louisiana 70803, and Department of Chemistry, Duke University, Box 90346, Durham, North Carolina 27708-0346
| |
Collapse
|