Hofstetter LW, Odéen H, Bolster BD, Christensen DA, Payne A, Parker DL. Magnetic resonance shear wave elastography using transient acoustic radiation force excitations and sinusoidal displacement encoding. Phys Med Biol 2021; 66. [PMID: 33352538 DOI: 10.1088/1361-6560/abd5ce] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2020] [Accepted: 12/22/2020] [Indexed: 12/31/2022]
Abstract
A magnetic resonance (MR) shear wave elastography technique that uses transient acoustic radiation force impulses from a focused ultrasound (FUS) transducer and a sinusoidal-shaped MR displacement encoding strategy is presented. Using this encoding strategy, an analytic expression for calculating the shear wave speed in a heterogeneous medium was derived. Green's function-based simulations were used to evaluate the feasibility of calculating shear wave speed maps using the analytic expression. Accuracy of simulation technique was confirmed experimentally in a homogeneous gelatin phantom. The elastography measurement was compared to harmonic MR elastography in a homogeneous phantom experiment and the measured shear wave speed values differed by less than 14%. This new transient elastography approach was able to map the position and shape of inclusions sized from 8.5 to 14 mm in an inclusion phantom experiment. These preliminary results demonstrate the feasibility of using a straightforward analytic expression to generate shear wave speed maps from MR images where sinusoidal-shaped motion encoding gradients are used to encode the displacement-time history of a transiently propagating wave-packet. This new measurement technique may be particularly well suited for performing elastography before, during, and after MR-guided FUS therapies since the same device used for therapy is also used as an excitation source for elastography.
Collapse
Affiliation(s)
- Lorne W Hofstetter
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, United States of America
| | - Henrik Odéen
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, United States of America
| | - Bradley D Bolster
- Siemens Medical Solutions USA, Inc., Salt Lake City, Utah, United States of America
| | - Douglas A Christensen
- Department of Bioengineering, University of Utah, Salt Lake City, Utah, United States of America.,Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, Utah, United States of America
| | - Allison Payne
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, United States of America
| | - Dennis L Parker
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, United States of America
| |
Collapse
|
2
|
Acoustic Radiation Force Based Ultrasound Elasticity Imaging for Biomedical Applications. SENSORS 2018; 18:s18072252. [PMID: 30002352 PMCID: PMC6069000 DOI: 10.3390/s18072252] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/13/2018] [Revised: 07/03/2018] [Accepted: 07/11/2018] [Indexed: 01/02/2023]
Abstract
Pathological changes in biological tissue are related to the changes in mechanical properties of biological tissue. Conventional medical screening tools such as ultrasound, magnetic resonance imaging or computed tomography have failed to produce the elastic properties of biological tissues directly. Ultrasound elasticity imaging (UEI) has been proposed as a promising imaging tool to map the elastic parameters of soft tissues for the clinical diagnosis of various diseases include prostate, liver, breast, and thyroid gland. Existing UEI-based approaches can be classified into three groups: internal physiologic excitation, external excitation, and acoustic radiation force (ARF) excitation methods. Among these methods, ARF has become one of the most popular techniques for the clinical diagnosis and treatment of disease. This paper provides comprehensive information on the recently developed ARF-based UEI techniques and instruments for biomedical applications. The mechanical properties of soft tissue, ARF and displacement estimation methods, working principle and implementation instruments for each ARF-based UEI method are discussed.
Collapse
|
3
|
Konofagou EE, Maleke C, Vappou J. Harmonic Motion Imaging (HMI) for Tumor Imaging and Treatment Monitoring. Curr Med Imaging 2012; 8:16-26. [PMID: 25364321 DOI: 10.2174/157340512799220616] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Palpation is an established screening procedure for the detection of several superficial cancers including breast, thyroid, prostate, and liver tumors through both self and clinical examinations. This is because solid masses typically have distinct stiffnesses compared to the surrounding normal tissue. In this paper, the application of Harmonic Motion Imaging (HMI) for tumor detection based on its stiffness as well as its relevance in thermal treatment is reviewed. HMI uses a focused ultrasound (FUS) beam to generate an oscillatory acoustic radiation force for an internal, non-contact palpation to internally estimate relative tissue hardness. HMI studies have dealt with the measurement of the tissue dynamic motion in response to an oscillatory acoustic force at the same frequency, and have been shown feasible in simulations, phantoms, ex vivo human and bovine tissues as well as animals in vivo. Using an FUS beam, HMI can also be used in an ideal integration setting with thermal ablation using high-intensity focused ultrasound (HIFU), which also leads to an alteration in the tumor stiffness. In this paper, a short review of HMI is provided that encompasses the findings in all the aforementioned areas. The findings presented herein demonstrate that the HMI displacement can accurately depict the underlying tissue stiffness, and the HMI image of the relative stiffness could accurately detect and characterize the tumor or thermal lesion based on its distinct properties. HMI may thus constitute a non-ionizing, cost-efficient and reliable complementary method for noninvasive tumor detection, localization, diagnosis and treatment monitoring.
Collapse
Affiliation(s)
- Elisa E Konofagou
- Department of Biomedical Engineering, Columbia University, 351 Engineering Terrace, Mail Code 8904, 1210 Amsterdam Avenue, New York, NY 10027, USA
| | - Caroline Maleke
- Department of Biomedical Engineering, Columbia University, 351 Engineering Terrace, Mail Code 8904, 1210 Amsterdam Avenue, New York, NY 10027, USA
| | - Jonathan Vappou
- Department of Biomedical Engineering, Columbia University, 351 Engineering Terrace, Mail Code 8904, 1210 Amsterdam Avenue, New York, NY 10027, USA
| |
Collapse
|
4
|
Arani A, Plewes D, Chopra R. Transurethral prostate magnetic resonance elastography: prospective imaging requirements. Magn Reson Med 2010; 65:340-9. [PMID: 20882673 DOI: 10.1002/mrm.22633] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2010] [Revised: 06/22/2010] [Accepted: 08/16/2010] [Indexed: 12/20/2022]
Abstract
Tissue stiffness is known to undergo alterations when affected by prostate cancer and may serve as an indicator of the disease. Stiffness measurements can be made with magnetic resonance elastography performed using a transurethral actuator to generate shear waves in the prostate gland. The goal of this study was to help determine the imaging requirements of transurethral magnetic resonance elastography and to evaluate whether the spatial and stiffness resolution of this technique overlapped with the requirements for prostate cancer detection. Through the use of prostate-mimicking gelatin phantoms, frequencies of at least 400 Hz were necessary to obtain accurate stiffness measurements of 10 mm diameter inclusions, but the detection of inclusions with diameters as small as 4.75 mm was possible at 200 Hz. The shear wave attenuation coefficient was measured in vivo in the canine prostate gland, and was used to predict the detectable penetration depth of shear waves in prostate tissue. These results suggested that frequencies below 200 Hz could propagate to the prostate boundary with a signal to noise ratio (SNR) of 60 and an actuator capable of producing 60 μm displacements. These requirements are achievable with current imaging and actuator technologies, and motivate further investigation of magnetic resonance elastography for the targeting of prostate cancer.
Collapse
Affiliation(s)
- Arvin Arani
- Imaging Research, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada.
| | | | | |
Collapse
|
5
|
Xie B, Weaver JB, Meaney PM, Paulsen KD. Magnetic resonance microwave absorption imaging: feasibility of signal detection. Med Phys 2009; 36:5190-7. [PMID: 19994529 DOI: 10.1118/1.3215533] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Magnetic resonance (MR) technique was used to detect small displacements induced by localized absorption of pulsed 434 MHz microwave power as a potential method for tumor detection. METHODS Phase contrast subtraction was used to separate the phase change due to motion from thermoelastic expansion from other contributions to phase variation such as the bulk temperature rise of the medium and phase offsets from the MR scanner itself. A simple set of experiments was performed where the motion was constrained to be one dimensional which provided controls on the data acquisition and motion extraction procedures. Specifically, the MR-detected motion signal was isolated by altering the direction of the microwave-induced motion and sampling the response with motion encoding gradients in all three directions when the microwave power was turned on and turned off. RESULTS Successful signal detection, as evidenced by the recording of a systematic alternating (zigzag) phase pattern, occurred only when the motion encoding was in parallel with either the vertical or horizontal direction of the microwave-induced motion on both 10 and 4 mm spatial scales. CONCLUSIONS These results demonstrate, for the first time, that motion associated with thermoelastic expansion from the absorption of pulsed microwave power can be detected with MR.
Collapse
Affiliation(s)
- Bin Xie
- Thayer School of Engineering, Dartmouth College, Hanover New Hampshire 03755, USA
| | | | | | | |
Collapse
|
6
|
Atay SM, Kroenke CD, Sabet A, Bayly PV. Measurement of the dynamic shear modulus of mouse brain tissue in vivo by magnetic resonance elastography. J Biomech Eng 2008; 130:021013. [PMID: 18412500 DOI: 10.1115/1.2899575] [Citation(s) in RCA: 91] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
In this study, the magnetic resonance (MR) elastography technique was used to estimate the dynamic shear modulus of mouse brain tissue in vivo. The technique allows visualization and measurement of mechanical shear waves excited by lateral vibration of the skull. Quantitative measurements of displacement in three dimensions during vibration at 1200 Hz were obtained by applying oscillatory magnetic field gradients at the same frequency during a MR imaging sequence. Contrast in the resulting phase images of the mouse brain is proportional to displacement. To obtain estimates of shear modulus, measured displacement fields were fitted to the shear wave equation. Validation of the procedure was performed on gel characterized by independent rheometry tests and on data from finite element simulations. Brain tissue is, in reality, viscoelastic and nonlinear. The current estimates of dynamic shear modulus are strictly relevant only to small oscillations at a specific frequency, but these estimates may be obtained at high frequencies (and thus high deformation rates), noninvasively throughout the brain. These data complement measurements of nonlinear viscoelastic properties obtained by others at slower rates, either ex vivo or invasively.
Collapse
Affiliation(s)
- Stefan M Atay
- Department of Mechanical and Aerospace Engineering, Washington University, 1 Brookings Drive, Box 1185, St. Louis, MO 63130, USA
| | | | | | | |
Collapse
|
7
|
Lopez O, Amrami KK, Manduca A, Rossman PJ, Ehman RL. Developments in dynamic MR elastography for in vitro biomechanical assessment of hyaline cartilage under high-frequency cyclical shear. J Magn Reson Imaging 2007; 25:310-20. [PMID: 17260392 DOI: 10.1002/jmri.20857] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
The design, construction, and evaluation of a customized dynamic magnetic resonance elastography (MRE) technique for biomechanical assessment of hyaline cartilage in vitro are described. For quantification of the dynamic shear properties of hyaline cartilage by dynamic MRE, mechanical excitation and motion sensitization were performed at frequencies in the kilohertz range. A custom electromechanical actuator and a z-axis gradient coil were used to generate and image shear waves throughout cartilage at 1000-10,000 Hz. A radiofrequency (RF) coil was also constructed for high-resolution imaging. The technique was validated at 4000 and 6000 Hz by quantifying differences in shear stiffness between soft ( approximately 200 kPa) and stiff ( approximately 300 kPa) layers of 5-mm-thick bilayered phantoms. The technique was then used to quantify the dynamic shear properties of bovine and shark hyaline cartilage samples at frequencies up to 9000 Hz. The results demonstrate that one can obtain high-resolution shear stiffness measurements of hyaline cartilage and small, stiff, multilayered phantoms at high frequencies by generating robust mechanical excitations and using large magnetic field gradients. Dynamic MRE can potentially be used to directly quantify the dynamic shear properties of hyaline and articular cartilage, as well as other cartilaginous materials and engineered constructs.
Collapse
Affiliation(s)
- Orlando Lopez
- Department of Radiology, Mayo Clinic, Rochester, Minnesota 55905, USA
| | | | | | | | | |
Collapse
|
8
|
Rump J, Klatt D, Braun J, Warmuth C, Sack I. Fractional encoding of harmonic motions in MR elastography. Magn Reson Med 2007; 57:388-95. [PMID: 17260354 DOI: 10.1002/mrm.21152] [Citation(s) in RCA: 133] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
In MR elastography (MRE) shear waves are magnetically encoded by bipolar gradients that usually oscillate with the same frequency fv as the mechanical vibration. As a result, both the repetition time (TR) and echo time (TE) of such an MRE sequence are greater than the vibration period 1/fv. This causes long acquisition times and considerable signal dephasing in tissue with short transverse relaxation times. Here we propose a reverse concept with TR<or=1/fv which we call "fractional" MRE, i.e., only a fraction of one vibration cycle per TR, can be used for motion sensitization. The benefit of fractional MRE is twofold: 1) acquisition times in seconds can be achieved for a single-phase difference wave image, and 2) materials that combine low elasticity, high viscosity, and short T2* relaxation times show an increased phase-to-noise ratio (PNR). A twofold increase of the phase signal is predicted for liver-like materials. Volunteer studies performed in liver and biceps show the benefit of fractional MRE. Furthermore, we demonstrate the feasibility of the technique for in vivo myocardial MRE by visualizing transverse wave propagation in the interventricular septum (IVS).
Collapse
Affiliation(s)
- Jens Rump
- Department of Radiology, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | | | | | | | | |
Collapse
|
9
|
Hardy PA, Ridler AC, Chiarot CB, Plewes DB, Henkelman RM. Imaging articular cartilage under compression?cartilage elastography. Magn Reson Med 2005; 53:1065-73. [PMID: 15844160 DOI: 10.1002/mrm.20439] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
We constructed a device to compress small samples of articular cartilage while the samples were imaged in a 1.5 T imager. With the use of a piezoelectric piston, the device compressed 1-cm-diameter cylindrical samples of articular cartilage (200 microm) at a rate of 2 Hz. Simultaneously, we imaged the samples with a displacement-sensitive stimulated-echo acquisition mode (STEAM) sequence. We validated the technique using tissue that mimicked silicone samples. We compared the results from the same cartilage samples before and after they were degraded by digestion in trypsin. The extent of degradation was visualized from T(1)-weighted images of the samples after they were soaked in 0.5 mmolar of GdDTPA. The resulting elastographic images show compression and differential strain in directions both parallel and perpendicular to the surface of the cartilage. The static elastographic images that depict compression made before digestion and after 5 and 15 hr of trypsin digestion show that the elastic modulus of the samples decreased with a spatial variation consistent with the enzymatic digestion as revealed by the T(1) images. We believe this technique will be useful in studies of the mechanical properties of articular cartilage and other tissues, and may in the future be extended to the clinical setting.
Collapse
Affiliation(s)
- Peter A Hardy
- Center for Biomedical Engineering, University of Kentucky, Lexington, 40536, USA.
| | | | | | | | | |
Collapse
|
10
|
Plewes D, Luginbuhl C, Macgowan C, Sack I. An inductive method to measure mechanical excitation spectra for MRI elastography. ACTA ACUST UNITED AC 2004. [DOI: 10.1002/cmr.b.20011] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
11
|
Doyley MM, Weaver JB, Van Houten EEW, Kennedy FE, Paulsen KD. Thresholds for detecting and characterizing focal lesions using steady-state MR elastography. Med Phys 2003; 30:495-504. [PMID: 12722801 DOI: 10.1118/1.1556607] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
An objective contrast-detail analysis was performed in this study to assess the low contrast detectability of a clinical prototype harmonic magnetic resonance elastographic imaging system. Elastographic imaging was performed on gelatin phantoms containing spherical inclusions of varying size and modulus contrast. The results demonstrate that lesions as small as 5 mm can be detected with a minimum modulus contrast of 14 dB. However, the shear modulus of such small lesions was not accurately recovered. In general, the shear modulus of larger focal lesions was accurately (i.e., within 25% of the true value) recovered. The minimum modulus contrast needed to detect focal lesions was observed to decrease with increasing lesion size.
Collapse
Affiliation(s)
- Marvin M Doyley
- Department of Radiology, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire 03756, USA.
| | | | | | | | | |
Collapse
|
12
|
Madelin G, Baril N, Lewa CJ, Franconi JM, Canioni P, Thiaudiére E, de Certaines JD. Detection of acoustic waves by NMR using a radiofrequency field gradient. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2003; 161:108-111. [PMID: 12660117 DOI: 10.1016/s1090-7807(02)00184-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
A B(1) field gradient-based method previously described for the detection of mechanical vibrations has been applied to detect oscillatory motions in condensed matter originated from acoustic waves. A ladder-shaped coil generating a quasi-constant RF-field gradient was associated with a motion-encoding NMR sequence consisting in a repetitive binomial 13;31; RF pulse train (stroboscopic acquisition). The NMR response of a gel phantom subject to acoustic wave excitation in the 20-200 Hz range was investigated. Results showed a linear relationship between the NMR signal and the wave amplitude and a spectroscopic selectivity of the NMR sequence with respect to the input acoustic frequency. Spin displacements as short as a few tens of nanometers were able to be detected with this method.
Collapse
Affiliation(s)
- Guillaume Madelin
- Magnetic Resonance Center, University of Rennes 1 and Centre Eugène Marquis, Rennes, France
| | | | | | | | | | | | | |
Collapse
|
13
|
Baril N, Lewa CJ, de Certaines JD, Canioni P, Franconi JM, Thiaudière E. MR detection of mechanical vibrations using a radiofrequency field gradient. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2002; 154:22-27. [PMID: 11820823 DOI: 10.1006/jmre.2001.2451] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
A new method for NMR characterization of mechanical waves, based upon radiofrequency field gradient for motion encoding, is proposed. A binomial B1 gradient excitation scheme was used to visualize the mobile spins undergoing a periodic transverse mechanical excitation. A simple model was designed to simulate the NMR signal as a function of the wave frequency excitation and the periodicity of the NMR pulse sequence. The preliminary results were obtained on a gel phantom at low vibration frequencies (0-200 Hz) by using a ladder-shaped coil generating a nearly constant RF field gradient along a specific known direction. For very small displacements and/or B1 gradients, the NMR signal measured on a gel phantom was proportional to the vibration amplitude and the pulse sequence was shown to be selective with respect to the vibration frequency. A good estimation of the direction of vibrations was obtained by varying the angle between the motion direction and the B1 gradient. The method and its use in parallel to more conventional MR elastography techniques are discussed. The presented approach might be of interest for noninvasive investigation of elastic properties of soft tissues and other materials.
Collapse
Affiliation(s)
- Nathalie Baril
- Magnetic Resonance Centre, CNRS-Université Victor Segalen Bordeaux 2, Bordeaux, France
| | | | | | | | | | | |
Collapse
|