Malhotra A, Carpentier EE, Duzenli C. Recommendations for using analytical anisotropic algorithm and AcurosXB for epidermal dose calculations in breast radiotherapy from an in vivo Gafchromic film study. J Appl Clin Med Phys 2024; 25:e14416. [PMID: 38812120 PMCID: PMC11302804 DOI: 10.1002/acm2.14416] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2024] [Revised: 03/27/2024] [Accepted: 04/25/2024] [Indexed: 05/31/2024] Open
Abstract
BACKGROUND AND PURPOSE This study recommends clinical epidermal dose calculation methods based on in-vivo film measurements and registered skin dose distributions with the Eclipse (Varian Medical Systems) treatment planning system's Analytical Anisotropic Algorithm (AAA) and Acuros XB (AXB) dose calculation algorithms. MATERIALS AND METHODS Eighteen AAA V13.6 breast plans were recalculated using AXB (dose to medium) V13.5 with the same beam parameters and monitor units as in the original plans. These are compared against in-vivo Gafchromic film measurements from the lateral and inferior breast regions. Three skin structures in the treatment planning system are evaluated: a surface layer of voxels of the body contour, a 0.2 cm internal skin rind, and a 0.5 cm internal skin rind. RESULTS Systematic shifts are demonstrated between the film measurements of skin dose and the Eclipse dose calculations. On average, the dose to the surface layer of pixels is underestimated by AAA by 8% and overestimated by AXB by 3%. A 5 mm skin rind extended into the body can increase epidermal dose calculations on average by 8% for AAA and 4% for AXB. CONCLUSION This is the first study to register in-vivo skin dose distributions in the breast to the treatment planning system for comparison. Based on the results from this study it is recommended that epidermal dose is calculated with a 0.5 cm skin rind for the AAA algorithm and with rind thickness up to 0.2 cm for the AXB algorithm.
Collapse
Affiliation(s)
- Aria Malhotra
- BC CancerVancouverBritish ColumbiaCanada
- Department of Physics and AstronomyUniversity of British ColumbiaVancouverBritish ColumbiaCanada
| | - Emilie E. Carpentier
- BC CancerVancouverBritish ColumbiaCanada
- Department of Physics and AstronomyUniversity of British ColumbiaVancouverBritish ColumbiaCanada
| | - Cheryl Duzenli
- BC CancerVancouverBritish ColumbiaCanada
- Department of Physics and AstronomyUniversity of British ColumbiaVancouverBritish ColumbiaCanada
- Department of SurgeryDivision of Radiation Oncology and Experimental RadiotherapeuticsUniversity of British ColumbiaVancouverBritish ColumbiaCanada
| |
Collapse
|
2
|
Prunaretty J, Lopez L, Cabaillé M, Bourgier C, Morel A, Azria D, Fenoglietto P. Evaluation of Ethos intelligent optimization engine for left locally advanced breast cancer. Front Oncol 2024; 14:1399978. [PMID: 39015493 PMCID: PMC11250590 DOI: 10.3389/fonc.2024.1399978] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2024] [Accepted: 06/13/2024] [Indexed: 07/18/2024] Open
Abstract
Purpose To evaluate the feasibility to use a standard Ethos planning template to treat left-sided breast cancer with regional lymph nodes. Material/Methods The tuning cohort of 5 patients was used to create a planning template. The validation cohort included 15 patients treated for a locally advanced left breast cancer randomly enrolled. The Ethos planning template was tuned using standard 3 partial arc VMAT and two collimator rotation configurations: 45/285/345° and 30/60/330°. Re-planning was performed automatically using the template without editing. The study was conducted with a schedule of 42.3 Gy in 18 fractions to the breast/chestwall, internal mammary chain (IMC) and regional lymph nodes ("Nodes"). The PTV was defined as a 3D extension of the CTV with a margin of 7 mm, excluding the 5mm below the skin. The manual treatment plans were performed using Eclipse treatment planning system with AAA and PO algorithms (v15.6) and a manual arc VMAT configuration and imported in Ethos TPS (v1.1) for a dose calculation with Ethos Acuros algorithm. The automated plans were compared with the manual plans using PTV and CTV coverage, homogeneity and conformity indices (HI and CN) and doses to organs at risk (OAR) via DVH metrics. For each plan, the patient quality assurance (QA) were performed using Mobius3D and gamma index. Finally, two breast radiation oncologists performed a blinded assessment of the clinical acceptability of each of the three plans (manual and automated) for each patient. Results The manual and automated plans provided suitable treatment planning as regards dose constraints. The dosimetric comparison showed the CTV_breast D99% were significantly improved with both automated plans (p< 0,002) while PTV coverage was comparable. The doses to the organs at risk were equivalent for the three plans. Concerning treatment delivery, the Ethos-45° and Ethos-30° plans led to an increase in MUs compared to the manual plans, without affecting the beam on time. The average gamma index pass rates remained consistently above 98% regardless of the type of plan utilized. In the blinded evaluation, clinicians 1 and 2 assessed 13 out of 15 plans for Ethos 45° and 11 out of 15 plans for Ethos 30° as clinically acceptable. Conclusion Using a standard planning template for locally advanced breast cancer, the Ethos TPS provided automated plans that were clinically acceptable and comparable in quality to manually generated plans. Automated plans also dramatically reduce workflow and operator variability.
Collapse
Affiliation(s)
- Jessica Prunaretty
- Radiotherapy Department, Montpellier Regional Cancer Institute, Montpellier, France
| | | | | | | | | | | | | |
Collapse
|
3
|
Copeland-Halperin LR, Lyatskaya Y, Bellon JR, Dey T, Carty MJ, Barbie T, Erdmann-Sager J. Impact of Prepectoral vs. Subpectoral Tissue Expander Placement on Post-mastectomy Radiation Therapy Delivery: A Retrospective Cohort Study. PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN 2023; 11:e5434. [PMID: 38115839 PMCID: PMC10730031 DOI: 10.1097/gox.0000000000005434] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Accepted: 10/05/2023] [Indexed: 12/21/2023]
Abstract
Background Implant-based reconstruction is the most common method of postmastectomy reconstruction. Many patients require postmastectomy radiation (PMRT). Tissue expanders (TEs), typically inserted as a first stage, have historically been placed subpectorally. More recently, prepectoral reconstruction has gained popularity, but its impact on PMRT is unknown. Prior studies focus on complication rates and aesthetic outcomes. This study examines whether there is a difference in radiation dosimetry among patients undergoing prepectoral versus subpectoral TE reconstruction. Methods Electronic medical records and radiation plans of 50 patients (25 prepectoral, 25 subpectoral) who underwent mastectomy with immediate TE reconstruction at our institution or affiliate site were reviewed. Pectoralis major muscle and chest wall structures were contoured and mean percentage volumes of these structures receiving less than 95%, 100%, and more than 105% target radiation dose were calculated, as were heart and ipsilateral lung doses. Welch two sample t test, Fisher exact test, and Pearson chi-squared tests were performed. Results The groups had comparable patient and tumor characteristics and underwent similar ablative and reconstructive procedures and radiation dosimetry. Subpectoral patients had larger mean areas receiving less than 95% target dose ("cold spots"); prepectoral patients had larger mean areas receiving greater than 105% ("hot spots") and 100% target doses. There were no differences in chest wall, heart, and lung doses. Conclusions Our results demonstrate an increased mean percentage area of pectoralis cold spots with subpectoral reconstruction and increased area of hot spots and 100% dose delivery to the pectoralis in prepectoral patients. Larger studies should analyze long-term effects of prepectoral reconstruction on radiation dosing and recurrence rates.
Collapse
Affiliation(s)
| | - Yulia Lyatskaya
- Department of Radiation Oncology, Brigham and Women’s Hospital, Boston, Mass
| | - Jennifer R. Bellon
- Department of Radiation Oncology, Dana-Farber Cancer Institute, Boston, Mass
| | - Tanujit Dey
- Center for Surgery and Public Health, Brigham and Women’s Hospital, Boston, Mass
| | - Matthew J. Carty
- Department of Surgery, Brigham and Women’s Hospital, Boston, Mass
| | - Thanh Barbie
- Department of Surgery, Brigham and Women’s Hospital, Boston, Mass
| | | |
Collapse
|
4
|
Racka I, Majewska K, Winiecki J, Kiluk K. Hybrid planning techniques for early-stage left-sided breast cancer: dose distribution analysis and estimation of projected secondary cancer-relative risk. Acta Oncol 2023; 62:932-941. [PMID: 37516978 DOI: 10.1080/0284186x.2023.2238553] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Accepted: 06/30/2023] [Indexed: 08/01/2023]
Abstract
PURPOSE The purpose of this study was to evaluate three techniques of irradiation of left-sided breast cancer patients, three-dimensional conformal radiotherapy (3D-CRT), hybrid Intensity-Modulated Radiotherapy (h-IMRT), and hybrid Volumetric-Modulated Arc Therapy (h-VMAT, h-ARC), in terms of dose distribution in the planning target volume (PTV) and organs at risk (OARs). The second aim was to estimate the projected relative risk of radiation-induced secondary cancers for hybrid techniques. MATERIALS AND METHODS Three treatment plans were prepared in 3D-CRT, h-IMRT, and h-VMAT techniques for each of the 40 patients, who underwent CT simulation in deep inspiration breath-hold (DIBH). For hybrid techniques, plans were created by combining 3D-CRT and dynamic fields with an 80%/20% dose ratio for 3D-CRT and IMRT or VMAT. Cumulative dose-volume histograms were used to compare dose distributions within the PTV and OARs (heart, left anterior descending coronary artery [LAD], left and right lung [LL, RL], right breast [RB]). Projected risk ratios for secondary cancers were estimated relative to 3D-CRT using the organ equivalent dose (OED) concept for the Schneider's linear exponential, plateau, and full mechanistic dose-response model. RESULTS All plans fulfilled the PTV criterium: V95%≥95%. Compared to 3D-CRT, both hybrid techniques showed significantly better target coverage (PTV: V95%>98%, p < 0.001), and the best conformality was achieved by h-ARC plans (CI: 1.18 ± 0.09, p < 0.001). Compared to 3D-CRT and h-ARC, h-IMRT increased the average sum of monitor units (MU) over 129.9% (p < 0.001). H-ARC increased the mean dose of contralateral organs and the LL V5Gy parameter (p < 0.001). Both hybrid techniques significantly reduced the Dmax of the heart by 5 Gy. Compared to h-IMRT, h-ARC increased secondary cancer projected relative risk ratios for LL, RL, and RB by 18, 152, and 81%, respectively. CONCLUSIONS The results confirmed that both hybrid techniques provide better target quality and OARs sparing than 3D-CRT. Hybrid VMAT delivers less MU compared to hybrid IMRT but may increase the risk of radiation-induced secondary malignancies.
Collapse
Affiliation(s)
- Iga Racka
- Medical Physics Department, Prof. Franciszek Łukaszczyk Memorial Oncology Center, Bydgoszcz, Poland
| | - Karolina Majewska
- Medical Physics Department, Prof. Franciszek Łukaszczyk Memorial Oncology Center, Bydgoszcz, Poland
| | - Janusz Winiecki
- Medical Physics Department, Prof. Franciszek Łukaszczyk Memorial Oncology Center, Bydgoszcz, Poland
- Clinic of Oncology and Brachytherapy, Collegium Medicum in Bydgoszcz, Nicholas Copernicus University, Torun, Poland
| | | |
Collapse
|
5
|
Guebert A, Roumeliotis M, Wu CHD, Long K, Logie N, Graham T, Gourley A, Craighead P, Sia M, Quirk S. The transition in practice to reduce bolus use in post-mastectomy radiotherapy: A dosimetric study of skin and subcutaneous tissue. Med Dosim 2023; 48:113-117. [PMID: 36907800 DOI: 10.1016/j.meddos.2023.01.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Revised: 01/26/2023] [Accepted: 01/27/2023] [Indexed: 03/12/2023]
Abstract
To inform clinical practice for women receiving post-mastectomy radiotherapy (PMRT), this study demonstrates the dosimetric impact of removing daily bolus on skin and subcutaneous tissue. Two planning strategies were used: clinical field-based (n = 30) and volume-based planning (n = 10). The clinical field-based plans were created with bolus and recalculated without bolus for comparison. The volume-based plans were created with bolus to ensure a minimum target coverage of the chest wall PTV and recalculated without bolus. In each scenario, the dose to superficial structures, including skin (3 mm and 5 mm) and subcutaneous tissue (a 2 mm layer, 3 mm deep from surface) were reported. Additionally, the difference in the clinically evaluated dosimetry to skin and subcutaneous tissue in volume-based plans were recalculated using Acuros (AXB) and compared to the Anisotropic Analytical Algorithm (AAA) algorithm. For all treatment planning strategies, chest wall coverage (V90%) was maintained. As expected, superficial structures demonstrate significant loss in coverage. The largest difference observed in the most superficial 3 mm where V90% coverage is reduced from a mean (± standard deviation) of 95.1% (± 2.8) to 18.9% (± 5.6) for clinical field-based treatments with and without bolus, respectively. For volume-based planning, the subcutaneous tissue maintains a V90% of 90.5% (± 7.0) compared to the clinical field-based planning coverage of 84.4% (± 8.0). In all skin and subcutaneous tissue, the AAA algorithm underestimates the volume of the 90% isodose. Removing bolus results in minimal dosimetric differences in the chest wall and significantly lower skin dose while dose to the subcutaneous tissue is maintained. Unless the skin has disease involvement, the most superficial 3 mm is not considered part of the target volume. The continued use of the AAA algorithm is supported for the PMRT setting.
Collapse
Affiliation(s)
- Alexandra Guebert
- Department of Physics & Astronomy, University of Calgary, Calgary, AB, Canada
| | - Michael Roumeliotis
- Department of Physics & Astronomy, University of Calgary, Calgary, AB, Canada; Department of Oncology, University of Calgary, Calgary, AB, Canada; Tom Baker Cancer Centre, Calgary, AB, Canada
| | | | - Karen Long
- Tom Baker Cancer Centre, Calgary, AB, Canada
| | - Natalie Logie
- Department of Oncology, University of Calgary, Calgary, AB, Canada; Tom Baker Cancer Centre, Calgary, AB, Canada
| | | | | | - Peter Craighead
- Department of Oncology, University of Calgary, Calgary, AB, Canada; Tom Baker Cancer Centre, Calgary, AB, Canada
| | - Michael Sia
- Department of Oncology, University of Calgary, Calgary, AB, Canada; Tom Baker Cancer Centre, Calgary, AB, Canada
| | - Sarah Quirk
- Department of Physics & Astronomy, University of Calgary, Calgary, AB, Canada; Department of Oncology, University of Calgary, Calgary, AB, Canada; Tom Baker Cancer Centre, Calgary, AB, Canada.
| |
Collapse
|
6
|
Racka I, Majewska K, Winiecki J. Three-dimensional conformal radiotherapy (3D-CRT) vs. volumetric modulated arc therapy (VMAT) in deep inspiration breath-hold (DIBH) technique in left-sided breast cancer patients-comparative analysis of dose distribution and estimation of projected secondary cancer risk. Strahlenther Onkol 2023; 199:90-101. [PMID: 35943553 DOI: 10.1007/s00066-022-01979-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Accepted: 07/07/2022] [Indexed: 01/18/2023]
Abstract
PURPOSE The purpose of this study was to compare two techniques of irradiation of left-sided breast cancer patients who underwent breast-conserving surgery, three-dimensional conformal radiotherapy technique (3D-CRT) and volumetric modulated arc therapy (VMAT), in terms of dose distribution in the planning target volume (PTV) and organs at risk (OARs). The second aim of the study was estimation of the projected risk of radiation-induced secondary cancer for both radiotherapy techniques. MATERIALS AND METHODS For 25 patients who underwent CT simulation in deep inspiration breath-hold (DIBH), three treatment plans were generated: one using a three-dimensional conformal radiotherapy technique and two using volumetric modulated arc therapy. First VMAT-DIBH geometry consisted of three partial arcs (ARC-DIBH 3A) and second consisted of four partial arcs (ARC-DIBH 4A). Cumulative dose-volume histograms (DVHs) were used to compare dose distributions within the PTV and OARs (heart, left anterior descending coronary artery [LAD], ipsilateral and contralateral lung [IL, CL], and contralateral breast [CB]). Normal tissue complication probabilities (NTCPs) and organ equivalent doses (OEDs) were calculated using the differential DVHs. Excess absolute risks (EARs) for second cancers were estimated using Schneider's full mechanistic dose-response model. RESULTS All plans fulfilled the criterium for PTV V95% ≥ 95%. The PTV coverage, homogeneity, and conformity indices were significantly better for VMAT-DIBH. VMAT showed a significantly increased mean dose and V5Gy for all OARs, but reduced LAD Dmax by 15 Gy. For IL, CL, and CB, the 3D-CRT DIBH method achieved the lowest values of EAR: 28.38 per 10,000 PYs, 2.55 per 10,000 PYs, and 4.48 per 10,000 PYs (p < 0.001), compared to 40.29 per 10,000 PYs, 15.62 per 10,000 PYs, and 23.44 per 10,000 PYs for ARC-DIBH 3A plans and 41.12 per 10,000 PYs, 15.59 per 10,000 PYs, and 22.73 per 10,000 PYs for ARC-DIBH 4A plans. Both techniques provided negligibly low NTCPs for all OARs. CONCLUSION The study shows that VMAT-DIBH provides better OAR sparing against high doses. However, the large low-dose-bath (≤ 5 Gy) is still a concern due to the fact that a larger volume of normal tissues exposed to lower doses may increase a radiation-induced risk of secondary cancer.
Collapse
Affiliation(s)
- Iga Racka
- Medical Physics Department, Prof. Franciszek Łukaszczyk Memorial Oncology Centre in Bydgoszcz, Bydgoszcz, Poland.
| | - Karolina Majewska
- Medical Physics Department, Prof. Franciszek Łukaszczyk Memorial Oncology Centre in Bydgoszcz, Bydgoszcz, Poland
| | - Janusz Winiecki
- Medical Physics Department, Prof. Franciszek Łukaszczyk Memorial Oncology Centre in Bydgoszcz, Bydgoszcz, Poland.,Clinic of Oncology and Brachytherapy, Collegium Medicum in Bydgoszcz, Nicholas Copernicus University in Torun, Bydgoszcz, Poland
| |
Collapse
|
7
|
Cheung MLM, Kan MWK, Yeung VTY, Poon DMC, Kam MKM, Lee LKY, Chan ATC. The radiobiological effect of using Acuros XB vs anisotropic analytical algorithm on hepatocellular carcinoma stereotactic body radiation therapy. Med Dosim 2022; 47:161-165. [PMID: 35241348 DOI: 10.1016/j.meddos.2022.01.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Revised: 01/23/2022] [Accepted: 01/31/2022] [Indexed: 11/26/2022]
Abstract
The purpose of this work was to study the radiobiological effect of using Acuros XB (AXB) vs Analytic Anisotropic Algorithm (AAA) on hepatocellular carcinoma (HCC) stereotactic body radiation therapy (SBRT). Seventy SBRT volumetric modulated arc therapy (VMAT) plans for HCC were calculated using AAA and AXB respectively with the same treatment parameters. Published tumor control probability (TCP) and normal tissue complication probability (NTCP) models were used to quantify the effect of dosimetric difference between AAA and AXB on TCP, NTCP and uncomplicated tumor control probability (UTCP). There was an average decrease of 2.5% in 6-month TCP. Normal liver has the largest average decrease in NTCP which was 59.7%. Bowels followed with 26.6% average decrease in NTCP. Duodenum, stomach and esophagus had 10.2%, 5.1%, and 4.3% average decrease in NTCP. There was an average decrease of 1.8% and up to 7.2% in 6-month UTCP. There was an overall decrease in TCP, NTCP, and UTCP for HCC SBRT plans calculated using AXB compared to AAA which could be clinically significant.
Collapse
Affiliation(s)
- Michael L M Cheung
- Department of Clinical Oncology, Prince of Wales Hospital, Hong Kong SAR, China; State Key Laboratory of Translational Oncology, The Chinese University of Hong Kong, Hong Kong SAR, China.
| | - Monica W K Kan
- Department of Clinical Oncology, Prince of Wales Hospital, Hong Kong SAR, China; State Key Laboratory of Translational Oncology, The Chinese University of Hong Kong, Hong Kong SAR, China
| | - Vanessa T Y Yeung
- Department of Clinical Oncology, Prince of Wales Hospital, Hong Kong SAR, China; State Key Laboratory of Translational Oncology, The Chinese University of Hong Kong, Hong Kong SAR, China
| | - Darren M C Poon
- State Key Laboratory of Translational Oncology, The Chinese University of Hong Kong, Hong Kong SAR, China
| | - Michael K M Kam
- State Key Laboratory of Translational Oncology, The Chinese University of Hong Kong, Hong Kong SAR, China
| | - Louis K Y Lee
- State Key Laboratory of Translational Oncology, The Chinese University of Hong Kong, Hong Kong SAR, China
| | - Anthony T C Chan
- Department of Clinical Oncology, Prince of Wales Hospital, Hong Kong SAR, China; State Key Laboratory of Translational Oncology, The Chinese University of Hong Kong, Hong Kong SAR, China
| |
Collapse
|
8
|
Kumar L, Bhushan M, Kishore V, Chowdhary R, Barik S, Sharma A, Gairola M. Dosimetric influence of acuros XB dose-to-medium and dose-to-water reporting modes on carcinoma cervix using intensity-modulated radiation therapy and volumetric rapidarc technique. J Med Phys 2022; 47:10-19. [PMID: 35548039 PMCID: PMC9084581 DOI: 10.4103/jmp.jmp_64_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Revised: 11/05/2021] [Accepted: 12/08/2021] [Indexed: 11/25/2022] Open
Abstract
Aim: We aimed to evaluate the dosimetric influence of Acuros XB (AXB) dose-to-medium (Dm) and dose-to-water (Dw) reporting mode on carcinoma cervix using intensity-modulated radiation therapy (IMRT) and RapidArc (RA) technique. Materials and Methods: A cohort of thirty patients cared for carcinoma cervix was retrospectively selected for the study. Plans were computed using analytical anisotropic algorithm (AAA), AXB-Dm, and AXB-Dw algorithms for dosimetric comparison. A paired t-test and Pitman–Morgan dispersion test were executed to appraise the difference in mean values and the inter-patient variability of the differences. Results: The dose–volume parameters were higher for AXB-Dw in contrast to AAA for IMRT and RA plans, excluding D98%, minimum dose to planning target volume (PTV) and rectum mean dose (RA). There was no systematic trend observed in dose–volume parameters for PTV and organs at risk (OARs) between AXB-Dm and AXB-Dw for IMRT and RA plans. The dose–volume parameters for target were higher for AXB-Dm in comparison to AAA in IMRT and RA plans, except D98% and minimum dose to PTV. Analysis envisaged less inter-patient variability while switching from AAA to AXB-Dm in comparison to those switching from AAA to AXB-Dw. Conclusions: The present study reveals the important difference between AAA, AXB-Dm, and AXB-Dw computations for cervix carcinoma using IMRT and RA techniques. The inter-patient variability and systematic difference in dose–volume parameters computed using AAA, AXB-Dm, and AXB-Dw algorithms present the possible impact on the dose prescription to PTV and their relative constraints to OARs for IMRT and RA techniques. This may help in the decision-making in clinic while switching from AAA to AXB (Dm or Dw) algorithm for cervix carcinoma using IMRT and RA techniques.
Collapse
|
9
|
Cheung MLM, Kan MW, Yeung VT, Poon DM, Kam MK, Lee LK, Chan AT. The effect on tumour control probability of using AXB algorithm in replacement of AAA for SBRT of hepatocellular carcinoma located at lung-liver boundary region. BJR Open 2021; 3:20210041. [PMID: 34877460 PMCID: PMC8611685 DOI: 10.1259/bjro.20210041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2021] [Revised: 09/16/2021] [Accepted: 09/30/2021] [Indexed: 11/19/2022] Open
Abstract
Objective: To retrospectively analyze the clinical impact on stereotactic body radiation therapy (SBRT) for hepatocellular carcinoma (HCC) located at lung–liver boundary due to the use of Acuros XB algorithm (AXB) in replacement of anisotropic analytical algorithm (AAA). Methods: 23 SBRT volumetric modulated arc therapy (VMAT) plans for HCC located at lung–liver boundary were calculated using AAA and AXB respectively with the same treatment parameters. The dose–volume data of the planned target volumes (PTVs) were compared. A published tumour control probability (TCP) model was used to calculate the effect of dosimetric difference between AAA and AXB on tumour control probability. Results: For dose calculated by AXB (Dose to medium), the D95% and D98% of the PTV were on average 2.4 and 3.1% less than that calculated by AAA. For dose calculated by AXB (dose to water), the D95% and D98% of the PTV were on average 1.8%, and 2.7% less than that calculated by AAA. Up to 5% difference in D95% and 8% difference in D98% were observed in the worst cases. The significant decrease in D95% calculated by AXB compared to AAA could result in a % decrease in 2 year TCP up to 8% in the worst case (from 46.8 to 42.9%). Conclusion: The difference in dose calculated by AAA and AXB could lead to significant difference in TCP for HCC SBRT located at lung–liver boundary region. Advances in knowledge: The difference in calculated dose and tumour control probability for HCC SBRT between AAA and AXB algorithm at lung–liver boundary region was compared.
Collapse
Affiliation(s)
| | | | | | - Darren Mc Poon
- State Key Laboratory of Translational Oncology, The Chinese University of Hong Kong, Hong Kong, SAR, China
| | - Michael Km Kam
- State Key Laboratory of Translational Oncology, The Chinese University of Hong Kong, Hong Kong, SAR, China
| | - Louis Ky Lee
- State Key Laboratory of Translational Oncology, The Chinese University of Hong Kong, Hong Kong, SAR, China
| | | |
Collapse
|
10
|
Costa E, Richir T, Robilliard M, Bragard C, Logerot C, Kirova Y, Fourquet A, De Marzi L. Assessment of a conventional volumetric-modulated arc therapy knowledge-based planning model applied to the new Halcyon© O-ring linac in locoregional breast cancer radiotherapy. Phys Med 2021; 86:32-43. [PMID: 34051551 DOI: 10.1016/j.ejmp.2021.05.022] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/21/2021] [Revised: 03/31/2021] [Accepted: 05/13/2021] [Indexed: 10/21/2022] Open
Abstract
INTRODUCTION The aim of this study was to evaluate the performance of a knowledge-based planning (KBP) model for breast cancer trained on plans performed on a conventional linac with 6 MV FF (flattening filter) beams and volumetric-modulated arc therapy (VMAT) for plans performed on the new jawless Halcyon© system with 6 MV FFF (flattening filter-free) beams. MATERIALS AND METHODS Based on the RapidPlan© (RP) KBP optimization engine, a DVH Estimation Model was first trained using 56 VMAT left-sided breast cancer treatment plans performed on a conventional linac, and validated on another 20 similar cases (without manual intervention). To determine the capacity of the model for Halcyon©, an additional cohort of 20 left-sided breast cancer plans was generated with RP and analyzed for both TrueBeam© and Halcyon© machines. Plan qualities between manual vs RP (followed by manual intervention) Halcyon© plans set were compared qualitatively by blinded review by radiation oncologists for 10 new independent plans. RESULTS Halcyon© plans generated with the VMAT model trained with conventional linac plans showed comparable target dose distribution compared to TrueBeam© plans. Organ sparingwas comparable between the 2 devices with a slight decrease in heart dose for Halcyon© plans. Nine out of ten automatically generated Halcyon© plans were preferentially chosen by the radiation oncologists over the manually generated Halcyon© plans. CONCLUSION A VMAT KBP model driven by plans performed on a conventional linac with 6 MV FF beams provides high quality plans performed with 6 MV FFF beams on the new Halcyon© linac.
Collapse
Affiliation(s)
- Emilie Costa
- Institut Curie, Radiation Oncology Department, 26 rue d'Ulm, Paris 75005, France.
| | - Thomas Richir
- Institut Curie, Radiation Oncology Department, 26 rue d'Ulm, Paris 75005, France
| | - Magalie Robilliard
- Institut Curie, Radiation Oncology Department, 26 rue d'Ulm, Paris 75005, France
| | - Christel Bragard
- Institut Curie, Radiation Oncology Department, 26 rue d'Ulm, Paris 75005, France
| | - Christelle Logerot
- Institut Curie, Radiation Oncology Department, 26 rue d'Ulm, Paris 75005, France
| | - Youlia Kirova
- Institut Curie, Radiation Oncology Department, 26 rue d'Ulm, Paris 75005, France
| | - Alain Fourquet
- Institut Curie, Radiation Oncology Department, 26 rue d'Ulm, Paris 75005, France
| | - Ludovic De Marzi
- Institut Curie, Radiation Oncology Department, 26 rue d'Ulm, Paris 75005, France; Institut Curie, University Paris Saclay, PSL Research University, Inserm LITO, Orsay, France
| |
Collapse
|
11
|
Kumar L, Kishore V, Bhushan M, Dewan A, Yadav G, Raman K, Kumar G, Ahmad I, Chufal KS, Gairola M. Impact of acuros XB algorithm in deep-inspiration breath-hold (DIBH) respiratory techniques used for the treatment of left breast cancer. Rep Pract Oncol Radiother 2020; 25:507-514. [PMID: 32494224 DOI: 10.1016/j.rpor.2020.04.011] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2019] [Revised: 03/06/2020] [Accepted: 04/15/2020] [Indexed: 12/25/2022] Open
Abstract
Aim To investigate the impact of Acuros XB (AXB) algorithm in the deep-inspiration breath-hold (DIBH) technique used for treatment of left sided breast cancer. Background AXB may estimate better lung toxicities and treatment outcome in DIBH. Materials and Methods Treatment plans were computed using the field-in-field technique for a 6 MV beam in two respiratory phases - free breathing (FB) and DIBH. The AXB-calculations were performed under identical beam setup and the same numbers of monitor units as used for AAA-calculation. Results Mean Hounsfield units (HU), mass density (g/cc) and relative electron density were -782.1 ± 24.8 and -883.5 ± 24.9; 0.196 ± 0.025 and 0.083 ± 0.032; 0.218 ± 0.025 and 0.117 ± 0.025 for the lung in the FB and DIBH respiratory phase, respectively. For a similar target coverage (p > 0.05) in the DIBH respiratory phase between the AXB and AAA algorithm, there was a slight increase in organ at risk (OAR) dose for AXB in comparison to AAA, except for mean dose to the ipsilateral lung. AAA predicts higher mean dose to the ipsilateral lung and lesser V20Gy for the ipsilateral and common lung in comparison to AXB. The differences in mean dose to the ipsilateral lung were 0.87 ± 2.66 % (p > 0.05) in FB, and 1.01 ± 1.07% (p < 0.05) in DIBH, in V20Gy the differences were 1.76 ± 0.83% and 1.71 ± 0.82% in FB (p < 0.05), 3.34 ± 1.15 % and 3.24 ± 1.17 % in DIBH (p < 0.05), for the ipsilateral and common lung, respectively. Conclusion For a similar target volume coverage, there were important differences between the AXB and AAA algorithm for low-density inhomogeneity medium present in the DIBH respiratory phase for left sided breast cancer patients. DIBH treatment in conjunction with AXB may result in better estimation of lung toxicities and treatment outcome.
Collapse
Affiliation(s)
- Lalit Kumar
- Department of Applied Science & Humanities, Dr. A.P.J Abdul Kalam Technical University, Lucknow, India.,Medical Physics Division & Radiation Oncology Department, Rajiv Gandhi Cancer Institute and Research Center, New Delhi, India
| | - Vimal Kishore
- Department of Applied Science & Humanities, Bundelkhand Institute of Engineering & Technology, Jhansi, India
| | - Manindra Bhushan
- Medical Physics Division & Radiation Oncology Department, Rajiv Gandhi Cancer Institute and Research Center, New Delhi, India
| | - Abhinav Dewan
- Medical Physics Division & Radiation Oncology Department, Rajiv Gandhi Cancer Institute and Research Center, New Delhi, India
| | - Girigesh Yadav
- Medical Physics Division & Radiation Oncology Department, Rajiv Gandhi Cancer Institute and Research Center, New Delhi, India
| | - Kothanda Raman
- Medical Physics Division & Radiation Oncology Department, Rajiv Gandhi Cancer Institute and Research Center, New Delhi, India
| | - Gourav Kumar
- Medical Physics Division & Radiation Oncology Department, Rajiv Gandhi Cancer Institute and Research Center, New Delhi, India
| | - Irfan Ahmad
- Medical Physics Division & Radiation Oncology Department, Rajiv Gandhi Cancer Institute and Research Center, New Delhi, India
| | - Kundan S Chufal
- Medical Physics Division & Radiation Oncology Department, Rajiv Gandhi Cancer Institute and Research Center, New Delhi, India
| | - Munish Gairola
- Medical Physics Division & Radiation Oncology Department, Rajiv Gandhi Cancer Institute and Research Center, New Delhi, India
| |
Collapse
|
12
|
Bedford JL. Calculation of absorbed dose in radiotherapy by solution of the linear Boltzmann transport equations. Phys Med Biol 2019; 64:02TR01. [PMID: 30524016 DOI: 10.1088/1361-6560/aaf0e2] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Over the last decade, dose calculations which solve the linear Boltzmann transport equations have been introduced into clinical practice and are now in widespread use. However, knowledge in the radiotherapy community concerning the details of their function is limited. This review gives a general description of the linear Boltzmann transport equations as applied to calculation of absorbed dose in clinical radiotherapy. The aim is to elucidate the principles of the method, rather than to describe a particular implementation. The literature on the performance of typical algorithms is then reviewed, in many cases with reference to Monte Carlo simulations. The review is completed with an overview of the emerging applications in the important area of MR-guided radiotherapy.
Collapse
Affiliation(s)
- James L Bedford
- Joint Department of Physics, The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London SM2 5PT, United Kingdom
| |
Collapse
|