1
|
Mann T, Ploquin N, Faruqi S, Loewen S, Thind K. Stereotactic Optimized Automated Radiotherapy (SOAR): a novel automated planning solution for multi-metastatic SRS compared to HyperArc™. Biomed Phys Eng Express 2024; 10:025037. [PMID: 38364285 DOI: 10.1088/2057-1976/ad2a1b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Accepted: 02/16/2024] [Indexed: 02/18/2024]
Abstract
Objective.Automated Stereotactic Radiosurgery (SRS) planning solutions improve clinical efficiency and reduce treatment plan variability. Available commercial solutions employ a template-based strategy that may not be optimal for all SRS patients. This study compares a novel beam angle optimized Volumetric Modulated Arc Therapy (VMAT) planning solution for multi-metastatic SRS to the commercial solution HyperArc.Approach.Stereotactic Optimized Automated Radiotherapy (SOAR) performs automated plan creation by combining collision prediction, beam angle optimization, and dose optimization to produce individualized high-quality SRS plans using Eclipse Scripting. In this retrospective study 50 patients were planned using SOAR and HyperArc. Assessed dose metrics included the Conformity Index (CI), Gradient Index (GI), and doses to organs-at-risk. Complexity metrics evaluated the modulation, gantry speed, and dose rate complexity. Plan dosimetric quality, and complexity were compared using double-sided Wilcoxon signed rank tests (α= 0.05) adjusted for multiple comparisons.Main Results.The median target CI was 0.82 with SOAR and 0.79 with HyperArc (p < .001). Median GI was 1.85 for SOAR and 1.68 for HyperArc (p < .001). The median V12Gy normal brain volume for SOAR and HyperArc were 7.76 cm3and 7.47 cm3respectively. Median doses to the eyes, lens, optic nerves, and optic chiasm were statistically significant favoring SOAR. The SOAR algorithm scored lower for all complexity metrics assessed.Significance.In-house developed automated planning solutions are a viable alternative to commercial solutions. SOAR designs high-quality patient-specific SRS plans with a greater degree of versatility than template-based methods.
Collapse
Affiliation(s)
- Thomas Mann
- Department of Physics and Astronomy, University of Calgary, AB, Canada
- Division of Medical Physics, Department of Oncology, Tom Baker Cancer Centre, University of Calgary, AB, Canada
| | - Nicolas Ploquin
- Department of Physics and Astronomy, University of Calgary, AB, Canada
- Division of Medical Physics, Department of Oncology, Tom Baker Cancer Centre, University of Calgary, AB, Canada
| | - Salman Faruqi
- Division of Radiation Oncology, Department of Oncology, Tom Baker Cancer Centre, University of Calgary, Alberta, Canada
| | - Shaun Loewen
- Division of Radiation Oncology, Department of Oncology, Tom Baker Cancer Centre, University of Calgary, Alberta, Canada
| | - Kundan Thind
- Division of Medical Physics, Department of Oncology, Tom Baker Cancer Centre, University of Calgary, AB, Canada
- Department of Medical Physics, Henry Ford Health Systems, Detroit, MI, United States of America
| |
Collapse
|
2
|
Schindhelm R, Razinskas G, Ringholz J, Kraft J, Sauer OA, Wegener S. Evaluation of a head rest prototype for rotational corrections in three degrees of freedom. J Appl Clin Med Phys 2024; 25:e14172. [PMID: 37793069 PMCID: PMC10860431 DOI: 10.1002/acm2.14172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Revised: 08/22/2023] [Accepted: 09/25/2023] [Indexed: 10/06/2023] Open
Abstract
Cranial stereotactic irradiations require accurate reproduction of the planning CT patient position at the time of treatment, including removal of rotational offsets. A device prototype was evaluated for potential clinical use to correct rotational positional offsets in image-guided radiotherapy workflow. Analysis was carried out with a prototype device "RPS head" by gKteso GmbH, rotatable up to 4° in three dimensions by hand wheels. A software tool accounts for the nonrectangular rotation axes and also indicates translational motions to be performed with the standard couch to correct the initial offset and translational shifts introduced by the rotational motion. The accuracy of angular corrections and positioning of an Alderson RANDO head phantom using the prototype device was evaluated for nine treatment plans for cranial targets. Corrections were obtained from cone beam computed tomography (CBCT) imaging. The phantom position was adjusted and the final position was then verified by another CBCT. The long-term stability of the prototype device was evaluated. Attenuation by the device along its three main axes was assessed. A planning study was performed to evaluate if regions of high-density material can be avoided during plan generation. The device enabled the accurate correction of rotational offsets in a clinical setup with a mean residual angular difference of (0.0 ± 0.1)° and a maximum deviation of 0.2°. Translational offsets were less than 1 mm. The device was stable over a period of 20 min, not changing the head support plate position by more than (0.7 ± 0.6) mm. The device contains high-density material in the adjustment mechanism and slightly higher density in the support structures. These can be avoided during planning generation maintaining comparable plan quality. The head positioning device can be used to correct rotational offsets in a clinical setting.
Collapse
Affiliation(s)
| | - Gary Razinskas
- Radiation OncologyUniversity Hospital WurzburgWurzburgGermany
| | - Jonas Ringholz
- Radiation OncologyUniversity Hospital WurzburgWurzburgGermany
| | - Johannes Kraft
- Radiation OncologyUniversity Hospital WurzburgWurzburgGermany
| | - Otto A. Sauer
- Radiation OncologyUniversity Hospital WurzburgWurzburgGermany
| | - Sonja Wegener
- Radiation OncologyUniversity Hospital WurzburgWurzburgGermany
| |
Collapse
|
3
|
Hanvey S, Hackett P, Winch L, Lim E, Laney R, Welsh L. A multi-centre stereotactic radiosurgery planning study of multiple brain metastases using isocentric linear accelerators with 5 and 2.5 mm width multi-leaf collimators, CyberKnife and Gamma Knife. BJR Open 2024; 6:tzae003. [PMID: 38371494 PMCID: PMC10873585 DOI: 10.1093/bjro/tzae003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2024] [Revised: 02/15/2024] [Accepted: 02/15/2024] [Indexed: 02/20/2024] Open
Abstract
Objectives This study compared plans of high definition (HD), 2.5 mm width multi-leaf collimator (MLC), to standard, 5 mm width, isocentric linear accelerator (linacs), CyberKnife (CK), and Gamma Knife (GK) for stereotactic radiosurgery (SRS) techniques on multiple brain metastases. Methods Eleven patients undergoing SRS for multiple brain metastases were chosen. Targets and organs at risk (OARs) were delineated and optimized SRS plans were generated and compared. Results The linacs delivered similar conformity index (CI) values, but the gradient index (GI) for HD MLCs was significantly lower (P-value <.001). Half the OARs received significantly lower dose using HD MLCs. CK delivered a significantly lower CI than HD MLC linac (P-value <.001), but a significantly higher GI (P-value <.001). CI was significantly improved with the HD MLC linac compared to GK (P-value = 4.591 × 10-3), however, GK delivered a significantly lower GI (P-value <.001). OAR dose sparing was similar for the HD MLC TL, CK, and GK. Conclusions Comparing linacs for SRS, the preferred choice is HD MLCs. Similar results were achieved with the HD MLC linac, CK, or GK, with each delivering significant improvements in different aspects of plan quality. Advances in knowledge This article is the first to compare HD and standard width MLC linac plans using a combination of single isocentre volumetric modulated arc therapy and multi-isocentric dynamic conformal arc plans as required, which is a more clinically relevant assessment. Furthermore, it compares these plans with CK and GK, assessing the relative merits of each technique.
Collapse
Affiliation(s)
- Scott Hanvey
- University Hospitals Plymouth NHS Trust, Plymouth, PL6 8DH, United Kingdom
| | | | - Lucy Winch
- University Hospitals Bristol NHS Foundation Trust, Bristol, BS2 8ED, United Kingdom
| | - Elizabeth Lim
- University Hospitals Plymouth NHS Trust, Plymouth, PL6 8DH, United Kingdom
- University of Plymouth, Plymouth, PL4 8AA, United Kingdom
| | - Robin Laney
- University Hospitals Plymouth NHS Trust, Plymouth, PL6 8DH, United Kingdom
| | - Liam Welsh
- The Royal Marsden, London, SW3 6JJ, United Kingdom
| |
Collapse
|
4
|
Golmakani S, McGrath AN, Williams TJ. Dosimetric effects of rotational errors for single isocenter multiple targets in HyperArc plans: A phantom and retrospective imaging analysis study. J Appl Clin Med Phys 2024; 25:e14214. [PMID: 38102815 PMCID: PMC10795450 DOI: 10.1002/acm2.14214] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Revised: 10/23/2023] [Accepted: 11/02/2023] [Indexed: 12/17/2023] Open
Abstract
PURPOSE This study uses a phantom to investigate the dosimetric impact of rotational setup errors for Single Isocenter Multiple Targets (SIMT) HyperArc plans. Additionally, it evaluates intra-fractional rotational setup errors in patients treated with Encompass immobilization system. METHODS The Varian HyperArc system (Varian Medical systems) was used to create plans targeting spherical PTVs with diameters of 5, 10, and 15 mm and with offsets of 1.3-5.3 cm from the isocenter. Dosimetric parameters, including mean and maximum dose, D99% and D95% were evaluated for various rotational setup errors ranging from 0.5° to 2° for the PTVs and certain CTVs created within PTVs. These rotational errors were applied in an order and direction that resulted in the maximum displacement of targets. The rotation was applied both uniformly around all three axes and individually around each axis. Furthermore, to link the findings to actual treatment scenarios, the intra-fractional rotational setup errors were obtained for stereotactic cranial patients treated with the Encompass system using CBCT images acquired during treatments. RESULTS The maximum displacement of 2.7 mm was observed for targets located at 4.4 and 4.5 cm from the isocenter with rotational setup errors of 2°. The dose reduction for D99% values corresponding to this displacement were about 50%, 40%, and 30% for PTVs with diameters of 5, 10, and 15 mm, respectively. Both D99% and D95% showed a consistent trend of dose reduction across various rotational errors and PTV volumes. While the maximum dose remained consistent for different targets with various rotational errors, the mean dose decreased by approximately 25%, 12%, and 6% for PTVs with diameters of 5, 10, and 15 cm, respectively, with rotational errors of 2°. In addition, by analyzing CBCT images, the absolute mean rotational setup errors obtained during treatment with Encompass for pitch, roll, and yaw were 0.17° ± 0.13°, 0.11° ± 0.10°, and 0.12° ± 0.10° respectively. This data, combined with existing studies, suggest that a 0.5° rotational setup error is a safe choice to consider for calculating additional PTV margin to ensure adequate CTV coverage. Therefore, the assessment of maximum displacement and dosimetric parameters in this study, for a 0.5° rotational error, highlights the need for an additional 0.7 mm PTV margin for targets positioned at distances of 4.4 cm or greater from the isocenter. CONCLUSIONS For SIMT Plans, a 0.5° rotational setup error is recommended as a basis for calculating additional PTV margins to ensure adequate CTV coverage when using the Encompass system.
Collapse
|
5
|
Lai JL, Liu SP, Jiang XX, Liu J, Li A, Li B, Li XK, Ye XJ, Lei KJ, Zhou L. Can Optical Surface Imaging Replace Non-coplanar Cone-beam Computed Tomography for Non-coplanar Set-up Verification in Single-isocentre Non-coplanar Stereotactic Radiosurgery and Hypofractionated Stereotactic Radiotherapy for Single and Multiple Brain Metastases? Clin Oncol (R Coll Radiol) 2023; 35:e657-e665. [PMID: 37778972 DOI: 10.1016/j.clon.2023.09.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2023] [Revised: 08/03/2023] [Accepted: 09/18/2023] [Indexed: 10/03/2023]
Abstract
AIMS To conduct a direct comparison regarding the non-coplanar positioning accuracy between the optical surface imaging system Catalyst HDTM and non-coplanar cone-beam computed tomography (NC-CBCT) in intracranial single-isocentre non-coplanar stereotactic radiosurgery (SRS) and hypofractionated stereotactic radiotherapy (HSRT). MATERIALS AND METHODS Twenty patients with between one and five brain metastases who underwent single-isocentre non-coplanar volumetric modulated arc therapy (NC-VMAT) SRS or HSRT were enrolled in this study. For each non-zero couch angle, both Catalyst HDTM and NC-CBCT were used for set-up verification prior to beam delivery. The set-up error reported by Catalyst HDTM was compared with the set-up error derived from NC-CBCT, which was defined as the gold standard. Additionally, the dose delivery accuracy of each non-coplanar field after using Catalyst HDTM and NC-CBCT for set-up correction was measured with SRS MapCHECKTM. RESULTS The median set-up error differences (absolute values) between the two positioning methods were 0.30 mm, 0.40 mm, 0.50 mm, 0.15°, 0.10° and 0.10° in the vertical, longitudinal, lateral, yaw, pitch and roll directions, respectively. The largest absolute set-up error differences regarding translation and rotation were 1.5 mm and 1.1°, which occurred in the longitudinal and yaw directions, respectively. Only 35.71% of the pairs of measurements were within the tolerance of 0.5 mm and 0.5° simultaneously. In addition, the non-coplanar field with NC-CBCT correction yielded a higher gamma passing rate than that with Catalyst HDTM correction (P < 0.05), especially for evaluation criteria of 1%/1 mm with a median increase of 12.8%. CONCLUSIONS Catalyst HDTM may not replace NC-CBCT for non-coplanar set-up corrections in single-isocentre NC-VMAT SRS and HSRT for single and multiple brain metastases. The potential role of Catalyst HDTM in intracranial SRS/HSRT needs to be further studied in the future.
Collapse
Affiliation(s)
- J L Lai
- Radiotherapy Physics & Technology Center, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - S P Liu
- Radiotherapy Physics & Technology Center, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - X X Jiang
- Radiotherapy Physics & Technology Center, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - J Liu
- Department of Oncology, Chengdu First People's Hospital, Chengdu, Sichuan, China
| | - A Li
- Radiotherapy Physics & Technology Center, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - B Li
- Radiotherapy Physics & Technology Center, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - X K Li
- West China Clinical Medical College of Sichuan University, Chengdu, Sichuan, China
| | - X J Ye
- Department of Oncology, Yibin Second People's Hospital, Yibin, Sichuan, China
| | - K J Lei
- Department of Oncology, Yibin Second People's Hospital, Yibin, Sichuan, China
| | - L Zhou
- Thoracic Oncology Ward, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, China.
| |
Collapse
|
6
|
Loebner HA, Mueller S, Volken W, Wallimann P, Aebersold DM, Stampanoni MFM, Fix MK, Manser P. Impact of the gradient in gantry-table rotation on dynamic trajectory radiotherapy plan quality. Med Phys 2023; 50:7104-7117. [PMID: 37748175 DOI: 10.1002/mp.16749] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Revised: 09/07/2023] [Accepted: 09/10/2023] [Indexed: 09/27/2023] Open
Abstract
BACKGROUND To improve organ at risk (OAR) sparing, dynamic trajectory radiotherapy (DTRT) extends VMAT by dynamic table and collimator rotation during beam-on. However, comprehensive investigations regarding the impact of the gantry-table (GT) rotation gradient on the DTRT plan quality have not been conducted. PURPOSE To investigate the impact of a user-defined GT rotation gradient on plan quality of DTRT plans in terms of dosimetric plan quality, dosimetric robustness, deliverability, and delivery time. METHODS The dynamic trajectories of DTRT are described by GT and gantry-collimator paths. The GT path is determined by minimizing the overlap of OARs with planning target volume (PTV). This approach is extended to consider a GT rotation gradient by means of a maximum gradient of the path (G m a x ${G}_{max}$ ) between two adjacent control points (G = | Δ table angle / Δ gantry angle | $G = | \Delta {{\mathrm{table\ angle}}/\Delta {\mathrm{gantry\ angle}}} |$ ) and maximum absolute change of G (Δ G m a x ${{\Delta}}{G}_{max}$ ). Four DTRT plans are created with different maximum G&∆G:G m a x ${G}_{max}$ &Δ G m a x ${{\Delta}}{G}_{max}$ = 0.5&0.125 (DTRT-1), 1&0.125 (DTRT-2), 3&0.125 (DTRT-3) and 3&1(DTRT-4), including 3-4 dynamic trajectories, for three clinically motivated cases in the head and neck and brain region (A, B, and C). A reference VMAT plan for each case is created. For all plans, plan quality is assessed and compared. Dosimetric plan quality is evaluated by target coverage, conformity, and OAR sparing. Dosimetric robustness is evaluated against systematic and random patient-setup uncertainties between± 3 mm $ \pm 3\ {\mathrm{mm}}$ in the lateral, longitudinal, and vertical directions, and machine uncertainties between± 4 ∘ $ \pm 4^\circ \ $ in the dynamically rotating machine components (gantry, table, collimator rotation). Delivery time is recorded. Deliverability and delivery accuracy on a TrueBeam are assessed by logfile analysis for all plans and additionally verified by film measurements for one case. All dose calculations are Monte Carlo based. RESULTS The extension of the DTRT planning process with user-definedG m a x & Δ G m a x ${G}_{max}\& {{\Delta}}{G}_{max}$ to investigate the impact of the GT rotation gradient on plan quality is successfully demonstrated. With increasingG m a x & Δ G m a x ${G}_{max}\& {{\Delta}}{G}_{max}$ , slight (case C,D m e a n , p a r o t i d l . ${D}_{mean,\ parotid\ l.}$ : up to-1Gy) and substantial (case A,D 0.03 c m 3 , o p t i c n e r v e r . ${D}_{0.03c{m}^3,\ optic\ nerve\ r.}$ : up to -9.3 Gy, caseB,D m e a n , b r a i n $\ {D}_{mean,\ brain}$ : up to -4.7Gy) improvements in OAR sparing are observed compared to VMAT, while maintaining similar target coverage. All plans are delivered on the TrueBeam. Expected and actual machine position values recorded in the logfiles deviated by <0.2° for gantry, table and collimator rotation. The film measurements agreed by >96% (2%global/2 mm Gamma passing rate) with the dose calculation. With increasingG m a x & Δ G m a x ${G}_{max}\& {{\Delta}}{G}_{max}$ , delivery time is prolonged by <2 min/trajectory (DTRT-4) compared to VMAT and DTRT-1. The DTRT plans for case A and B and the VMAT plan for case C plan reveal the best dosimetric robustness for the considered uncertainties. CONCLUSION The impact of the GT rotation gradient on DTRT plan quality is comprehensively investigated for three cases in the head and neck and brain region. Increasing freedom in this gradient improves dosimetric plan quality at the cost of increased delivery time for the investigated cases. No clear dependency of GT rotation gradient on dosimetric robustness is observed.
Collapse
Affiliation(s)
- Hannes A Loebner
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland
| | - Silvan Mueller
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland
| | - Werner Volken
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland
| | - Philipp Wallimann
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland
| | - Daniel M Aebersold
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland
| | | | - Michael K Fix
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland
| | - Peter Manser
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland
| |
Collapse
|
7
|
Faccenda V, Panizza D, Pisoni V, Trivellato S, Daniotti MC, Bianchi SP, De Ponti E, Arcangeli S. Single-Isocenter Linac-Based Radiosurgery for Brain Metastases with Coplanar Arcs: A Dosimetric and Clinical Analysis. Cancers (Basel) 2023; 15:4496. [PMID: 37760466 PMCID: PMC10526167 DOI: 10.3390/cancers15184496] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Revised: 09/04/2023] [Accepted: 09/07/2023] [Indexed: 09/29/2023] Open
Abstract
The efficacy of linac-based SRS/fSRS treatments using the single-isocenter coplanar FFF-VMAT technique for both single and multiple BM was investigated. Seventy patients (129 BM) treated with 15-21 Gy in 1 (n = 59) or 27 Gy in 3 (n = 11) fractions were analyzed. For each fraction, plans involving the intra-fractional errors measured by post-treatment CBCT were recalculated. The relationships of BM size, distance-to-isocenter, and barycenter shift with the difference in target coverage were evaluated. Clinical outcomes were assessed using logistic regression and Kaplan-Meier analysis. The median delivery time was 3.78 min (range, 1.83-9.25). The median post-treatment 3D error was 0.5 mm (range, 0.1-2.7) and the maximum rotational error was 0.3° (range, 0.0-1.3). In single BM patients, the GTV D95% was never reduced by >5%, whereas PTV D95% reductions >1% occurred in only 11 cases (29%). In multiple BM patients, dose deficits >5% and >1% occurred in 2 GTV (2%) and 34 PTV (37%), respectively. The differences in target coverage showed a moderate-to-strong correlation only with barycenter shift. Local failure of at least one treated BM occurred in 13 (21%) patients and the 1-year and 2-year local control rates for all lesions were 94% and 90%, respectively. The implemented workflow ensured that the degradation of target and brain dose metrics in delivered treatments was negligible. Along with encouraging clinical outcomes, these findings warrant a reduction in the PTV margins at our institution.
Collapse
Affiliation(s)
- Valeria Faccenda
- Medical Physics Department, Fondazione IRCCS San Gerardo dei Tintori, 20900 Monza, Italy; (V.F.); (D.P.); (S.T.); (M.C.D.); (E.D.P.)
| | - Denis Panizza
- Medical Physics Department, Fondazione IRCCS San Gerardo dei Tintori, 20900 Monza, Italy; (V.F.); (D.P.); (S.T.); (M.C.D.); (E.D.P.)
- School of Medicine and Surgery, University of Milan Bicocca, 20126 Milan, Italy;
| | - Valerio Pisoni
- Radiation Oncology Department, Fondazione IRCCS San Gerardo dei Tintori, 20900 Monza, Italy;
| | - Sara Trivellato
- Medical Physics Department, Fondazione IRCCS San Gerardo dei Tintori, 20900 Monza, Italy; (V.F.); (D.P.); (S.T.); (M.C.D.); (E.D.P.)
| | - Martina Camilla Daniotti
- Medical Physics Department, Fondazione IRCCS San Gerardo dei Tintori, 20900 Monza, Italy; (V.F.); (D.P.); (S.T.); (M.C.D.); (E.D.P.)
| | - Sofia Paola Bianchi
- School of Medicine and Surgery, University of Milan Bicocca, 20126 Milan, Italy;
| | - Elena De Ponti
- Medical Physics Department, Fondazione IRCCS San Gerardo dei Tintori, 20900 Monza, Italy; (V.F.); (D.P.); (S.T.); (M.C.D.); (E.D.P.)
- School of Medicine and Surgery, University of Milan Bicocca, 20126 Milan, Italy;
| | - Stefano Arcangeli
- School of Medicine and Surgery, University of Milan Bicocca, 20126 Milan, Italy;
- Radiation Oncology Department, Fondazione IRCCS San Gerardo dei Tintori, 20900 Monza, Italy;
| |
Collapse
|
8
|
Bolten JH, Dunst J, Siebert FA. Geometric accuracy in patient positioning for stereotactic radiotherapy of intracranial tumors. Phys Imaging Radiat Oncol 2023; 27:100461. [PMID: 37720460 PMCID: PMC10500024 DOI: 10.1016/j.phro.2023.100461] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2023] [Revised: 06/20/2023] [Accepted: 06/20/2023] [Indexed: 09/19/2023] Open
Abstract
Background/Purpose This study determines and compares the geometric setup errors between stereoscopic x-ray and kilo-voltage cone beam CT (CBCT) in phantom tests on a linear accelerator (linac) for image-guided (IG) stereotactic radiotherapy of intracranial tumors. Additionally, dose-volume metrics in the target volumes of the setup errors of CBCT were evaluated. Materials/Methods A Winston-Lutz- and an anthropomorphic phantom were used. The mean deviation and root mean square error (RMSE) of CBCT and stereoscopic x-ray were compared. Dose-volume metrics of the planning target volume (PTV) and gross target volume (GTV) for CBCT were calculated. Results The RMSEs in the tests with the Winston-Lutz-Phantom were 0.3 mm, 1.1 mm and 0.3 mm for CBCT and 0.1 mm, 0,1 mm and <0.1 mm for stereoscopic x-ray in the translational dimensions (right-left, anterior-posterior and superior-inferior). The RMSEs in the tests with the anthropomorphic phantom were 0.3 mm, 0.2 mm and 0.1 mm for CBCT and 0.1 mm, 0,1 mm and <0.1 mm for stereoscopic x-ray. The effects on dose-volume metrics of the setup errors of CBCT on the GTV were within 1 % for all considered dose values. The effects on the PTV were within 5 % for all considered dose values. Conclusion Both IG systems provide high accuracy patient positioning within a submillimeter range. The phantom tests exposed a slightly higher accuracy of stereoscopic x-ray than CBCT. The comparison with other studies with a similar purpose emphasizes the importance of individual IG installation quality assurance.
Collapse
Affiliation(s)
- Jan-Hendrik Bolten
- Clinic of Radiotherapy (Radiooncology), University Hospital Schleswig-Holstein, Campus Kiel, Kiel, Germany
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
| | - Jürgen Dunst
- Clinic of Radiotherapy (Radiooncology), University Hospital Schleswig-Holstein, Campus Kiel, Kiel, Germany
| | - Frank-André Siebert
- Clinic of Radiotherapy (Radiooncology), University Hospital Schleswig-Holstein, Campus Kiel, Kiel, Germany
| |
Collapse
|
9
|
Yamamoto Y, Ohira S, Kanayama N, Inui S, Ueda Y, Koike Y, Miyazaki M, Nishio T, Koizumi M, Konishi K. Comparison of dosimetric parameters and robustness for rotational errors in fractionated stereotactic irradiation using automated noncoplanar volumetric modulated arc therapy for patients with brain metastases: single- versus multi-isocentric technique. Radiol Phys Technol 2023; 16:310-318. [PMID: 37093409 DOI: 10.1007/s12194-023-00720-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Revised: 04/10/2023] [Accepted: 04/11/2023] [Indexed: 04/25/2023]
Abstract
To compare the dosimetric parameters of automated noncoplanar volumetric modulated arc therapy plans using single-isocentric (SIC) and multi-isocentric (MIC) techniques for patients with two brain metastases (BMs) in stereotactic irradiation and to evaluate the robustness of rotational errors. The SIC and MIC plans were retrospectively generated (35 Gy/five fractions) for 58 patients. Subsequently, a receiver operating characteristic curve analysis between the tumor surface distance (TSD) and V25Gy was performed to determine the thresholds for the brain tissue. The SIC and MIC plans were recalculated based on the rotational images to evaluate the dosimetric impact of rotational error. The MIC plans showed better brain tissue sparing for TSD > 6.6 cm. The SIC plans provided a significantly better conformity index for TSD ≤ 6.6 cm, while significantly lower gradient index was obtained (3.22 ± 0.56vs. 3.30 ± 0.57, p < 0.05) in the MIC plans with TSD > 6.6 cm. For organs at risk (OARs) (brainstem, chiasm, lens, optic nerves, and retinas), D0.1 cc was significantly lower (p < 0.05) in the MIC plans than in the SIC plans. The prescription dose could be delivered (D99%) to the gross tumor volume (GTV) for patients with TSD ≤ 6.6 cm when the rotational error was < 1°, whereas 31% of the D99% of GTV fell below the prescription dose with TSD > 6.6 cm. MIC plans can be an optimal approach for reducing doses to OARs and providing robustness against rotational errors in BMs with TSD > 6.6 cm.
Collapse
Affiliation(s)
- Yuki Yamamoto
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan
| | - Shingo Ohira
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Osaka, 537-8567, Japan.
| | - Naoyuki Kanayama
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Osaka, 537-8567, Japan
| | - Shoki Inui
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Osaka, 537-8567, Japan
| | - Yoshihiro Ueda
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Osaka, 537-8567, Japan
| | - Yuhei Koike
- Department of Radiology, Kansai Medical University, Osaka, Japan
| | - Masayoshi Miyazaki
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Osaka, 537-8567, Japan
| | - Teiji Nishio
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan
| | - Masahiko Koizumi
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan
| | - Koji Konishi
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Osaka, 537-8567, Japan
| |
Collapse
|
10
|
Yoon JW, Kim MY, Park S, Cheong KH, Kang SK, Koo T, Han TJ. Cross-irradiation in multiple isocenter frameless treatment for limited number of multiple brain metastases with volumetric modulated arc therapy. JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES 2023. [DOI: 10.1016/j.jrras.2023.100529] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
|
11
|
Lai J, Liu S, Liu J, Li X, Chen J, Jia Y, Lei K, Zhou L. Clinical Feasibility of Using Single-isocentre Non-coplanar Volumetric Modulated Arc Therapy Combined with Non-coplanar Cone Beam Computed Tomography in Hypofractionated Stereotactic Radiotherapy for Five or Fewer Multiple Intracranial Metastases. Clin Oncol (R Coll Radiol) 2023; 35:408-416. [PMID: 37002009 DOI: 10.1016/j.clon.2023.03.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2022] [Revised: 01/08/2023] [Accepted: 03/16/2023] [Indexed: 03/30/2023]
Abstract
AIMS To evaluate the clinical feasibility of single-isocentre non-coplanar volumetric modulated arc therapy (NC-VMAT) with non-coplanar cone beam computed tomography (NC-CBCT) in hypofractionated stereotactic radiotherapy (HSRT) for five or fewer multiple brain metastases. MATERIALS AND METHODS Ten patients with multiple brain metastases who underwent single-isocentre NC-VMAT HSRT with limited couch rotations (within ±45°) and NC-CBCT with a limited scanning range (150-200°) were included in the current analysis. Conventional single-isocentre coplanar VMAT (C-VMAT) plans were generated and compared with NC-VMAT plans. The intracranial response and toxicities of single-isocentre NC-VMAT HSRT were also evaluated. RESULTS Compared with C-VMAT, NC-VMAT generated better target conformity (P < 0.05), a lower gradient index (P < 0.05) and better normal brain tissue sparing, especially for volume ≥12 Gy, with a median reduction of 12.65 cm3. For 45° couch rotation, NC-CBCT produced sufficient image quality to differentiate bony anatomy, even with a 150° scanning range, which could be successfully used for patient set-up correction. After NC-CBCT, 57.1% of the measured non-coplanar set-up errors exceeded the threshold value. The median gamma passing rate of NC-VMAT was higher than that of C-VMAT plans (P < 0.05). The non-coplanar beam of NC-VMAT with NC-CBCT corrections exhibited superior gamma passing rate to that without NC-CBCT corrections. The intracranial objective response rate and disease control rate for all patients were 80% (8/10) and 100% (10/10), respectively, and the most common toxicities were headache (20%) and dizziness (20%). CONCLUSION NC-VMAT with limited couch rotation (within ±45°) combined with NC-CBCT with a limited scanning range (150-200°) markedly improves the plan quality and set-up accuracy in single-isocentre multiple-target HSRT.
Collapse
|
12
|
Foster RD, Moeller BJ, Robinson M, Bright M, Ruiz JL, Hampton CJ, Heinzerling JH. Dosimetric Analysis of Intra-Fraction Motion Detected by Surface-Guided Radiation Therapy During Linac Stereotactic Radiosurgery. Adv Radiat Oncol 2022; 8:101151. [PMID: 36691448 PMCID: PMC9860342 DOI: 10.1016/j.adro.2022.101151] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2022] [Accepted: 12/14/2022] [Indexed: 12/28/2022] Open
Abstract
Purpose Stereotactic radiosurgery (SRS) immobilization with an open face mask is more comfortable and less invasive than frame based, but concerns about intrafraction motion must be addressed. Surface-guided radiation therapy (SGRT) is an attractive option for intrafraction patient monitoring because it is continuous, has submillimeter accuracy, and uses no ionizing radiation. The purpose of this study was to investigate the dosimetric consequences of uncorrected intrafraction patient motion detected during frameless linac-based SRS. Methods and Materials Fifty-five SRS patients were monitored during treatment using SGRT between January 1, 2017, and September 30, 2020. If SGRT detected motion >1 mm, imaging was repeated and the necessary shifts were made before continuing treatment. For the 25 patients with intrafraction 3-dimensional vector shifts of ≥1 mm, we moved the isocenter in the planning system using the translational shifts from the repeat imaging and recalculated the plans to determine the dosimetric effect of the shifts. Planning target volume (PTV) coverage, minimum gross tumor volume (GTV) dose (relative and absolute), and normal brain V12 were evaluated. Wilcoxon signed rank tests were used to compare planned and simulated dosimetric parameters and median 2 sample tests were used to investigate these differences between cone and multileaf collimator (MLC) plans. Results For simulated plans, V12 increased by a median of 0.01 cc (P = .006) and relative GTV minimum dose and PTV coverage decreased by a median of 15.8% (P < .001) and 10.2 % (P < .001), respectively. Absolute minimum GTV dose was found to be significantly lower in the simulated plans (P < .001). PTV coverage decreased more for simulated cone plans than for simulated MLC plans (11.6% vs 4.7%, P = .011) but median V12 differences were found to be significantly larger for MLC plans (-0.34 cc vs -0.01 cc, P = .011). Differences in GTV minimum dose between cone and MLC plans were not statistically significant. Conclusions SGRT detected clinically meaningful intrafraction motion during frameless SRS, which could lead to large underdoses and increased normal brain dose if uncorrected.
Collapse
Affiliation(s)
- Ryan D. Foster
- Levine Cancer Institute, Atrium Health, Concord, North Carolina,Corresponding author: Ryan Foster, PhD
| | - Benjamin J. Moeller
- Levine Cancer Institute, Atrium Health and Southeast Radiation Oncology Group, Charlotte, North Carolina
| | - Myra Robinson
- Levine Cancer Institute, Atrium Health, Charlotte, North Carolina
| | - Megan Bright
- Levine Cancer Institute, Atrium Health, Concord, North Carolina
| | - Justin L. Ruiz
- Levine Cancer Institute, Atrium Health, Concord, North Carolina
| | | | - John H. Heinzerling
- Levine Cancer Institute, Atrium Health and Southeast Radiation Oncology Group, Charlotte, North Carolina
| |
Collapse
|
13
|
Chang S, Liu G, Zhao L, Zheng W, Yan D, Chen P, Li X, Deraniyagala R, Stevens C, Grills I, Chinnaiyan P, Li X, Ding X. Introduce a rotational robust optimization framework for spot-scanning proton arc (SPArc) therapy. Phys Med Biol 2022; 68. [PMID: 36546347 DOI: 10.1088/1361-6560/aca874] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Accepted: 12/02/2022] [Indexed: 12/03/2022]
Abstract
Objective. Proton dosimetric uncertainties resulting from the patient's daily setup errors in rotational directions exist even with advanced image-guided radiotherapy techniques. Thus, we developed a new rotational robust optimization SPArc algorithm (SPArcrot) to mitigate the dosimetric impact of the rotational setup error in Raystation ver. 6.02 (RaySearch Laboratory AB, Stockholm, Sweden).Approach.The initial planning CT was rotated ±5° simulating the worst-case setup error in the roll direction. The SPArcrotuses a multi-CT robust optimization framework by taking into account of such rotational setup errors. Five cases representing different disease sites were evaluated. Both SPArcoriginaland SPArcrotplans were generated using the same translational robust optimized parameters. To quantitatively investigate the mitigation effect from the rotational setup errors, all plans were recalculated using a series of pseudo-CT with rotational setup error (±1°/±2°/±3°/±5°). Dosimetric metrics such as D98% of CTV, and 3D gamma analysis were used to assess the dose distribution changes in the target and OARs.Main results.The magnitudes of dosimetric changes in the targets due to rotational setup error were significantly reduced by the SPArcrotcompared to SPArc in all cases. The uncertainties of the max dose to the OARs, such as brainstem, spinal cord and esophagus were significantly reduced using SPArcrot. The uncertainties of the mean dose to the OARs such as liver and oral cavity, parotid were comparable between the two planning techniques. The gamma passing rate (3%/3 mm) was significantly improved for CTV of all tumor sites through SPArcrot.Significance.Rotational setup error is one of the major issues which could lead to significant dose perturbations. SPArcrotplanning approach can consider such rotational error from patient setup or gantry rotation error by effectively mitigating the dose uncertainties to the target and in the adjunct series OARs.
Collapse
Affiliation(s)
- Sheng Chang
- Department of Radiation Oncology, Wuhan University, Renmin Hospital, Wuhan, 430060 Hubei Province, People's Republic of China.,Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, MI 48074, United States of America
| | - Gang Liu
- Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, MI 48074, United States of America.,Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430023, People's Republic of China
| | - Lewei Zhao
- Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, MI 48074, United States of America
| | - Weili Zheng
- Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, MI 48074, United States of America
| | - Di Yan
- Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, MI 48074, United States of America
| | - Peter Chen
- Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, MI 48074, United States of America
| | - Xiangpan Li
- Department of Radiation Oncology, Wuhan University, Renmin Hospital, Wuhan, 430060 Hubei Province, People's Republic of China
| | - Rohan Deraniyagala
- Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, MI 48074, United States of America
| | - Craig Stevens
- Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, MI 48074, United States of America
| | - Inga Grills
- Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, MI 48074, United States of America
| | - Prakash Chinnaiyan
- Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, MI 48074, United States of America
| | - Xiaoqiang Li
- Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, MI 48074, United States of America
| | - Xuanfeng Ding
- Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, MI 48074, United States of America
| |
Collapse
|
14
|
Comprehensive Analysis of Set-Up Gain of 6-Dimensional Cone-Beam CT Correction Method in Radiotherapy for Head and Neck and Brain Tumors. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2022; 2022:2964023. [PMID: 36311255 PMCID: PMC9613383 DOI: 10.1155/2022/2964023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Accepted: 10/01/2022] [Indexed: 11/18/2022]
Abstract
This study quantitatively analyzed the gain of the six-dimensional (6D) cone-beam CT (CBCT) correction method compared with the conventional set-up method in 60 patients who underwent radiation treatment of head and neck and brain tumors. The correction gain of CBCT was calculated for the translational and rotational motion components separately and in combination to evaluate the individual and overall effects of these motion components. Using a statistical simulation mimicking the actual set-up correction process, the effective gain of periodic CBCT correction during the entire treatment fraction was analyzed by target size and CBCT correction period under two different correction scenarios: translation alone and full 6D corrections. From the analyses performed in this study, the gain of CBCT correction was quantitatively determined for each situation, and the appropriate CBCT correction strategy was suggested based on treatment purpose and target size.
Collapse
|
15
|
Hayashi N, Kurata S, Saito Y, Ogawa S, Yasui K. Simple quality assurance based on filtered back projection for geometrical/irradiation accuracy in single-isocenter multiple-target stereotactic radiotherapy. Radiol Phys Technol 2022; 15:409-416. [PMID: 36261754 DOI: 10.1007/s12194-022-00683-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2022] [Revised: 10/04/2022] [Accepted: 10/05/2022] [Indexed: 10/24/2022]
Abstract
In single-isocenter multiple-target stereotactic radiotherapy (SIMT-SRT), it is difficult to evaluate both the geometrical accuracy and absorbed dose measurement when irradiating off-isocenter targets. This study aimed to develop a simple quality assurance (QA) method to evaluate off-isocenter irradiation position accuracy in SIMT-SRT and compare its feasibility with that of a commercial device. First, we created two types of inserts and metallic balls with a diameter of 5 mm to be inserted into a commercially available phantom (SIMT phantom). Second, we developed a dedicated analysis software using Python for the Winston-Lutz test (WLT). Third, an image processing software, including the filtered back-projection algorithm, was developed to analyze the images obtained using an electronic portal imaging device (EPID). Fourth, the feasibility of our method was evaluated by comparing it with the results of WLT using two commercially available phantoms: WL-QA and MultiMet-WL cubes. Notably, 92% of the results in one-dimensional deviations were within 0.26 mm (EPID pixel width). The correlation coefficients were 0.52, 0.92, and 0.96 in the left-right, superior-inferior, and anterior-posterior directions, respectively. In the WLT, a maximum two-dimensional deviation of 0.70 mm was detected in our method, while the deviation in the other method was within 0.5 mm. The advantage of our method is that it can evaluate the geometrical accuracy at any gantry angle during dynamic rotation irradiation using a filtered back-projection algorithm, even if the target is located off the isocenter. Our method can perform WLT at arbitrary positions and is suitable for the QA of dynamic rotation irradiation using an EPID.
Collapse
Affiliation(s)
- Naoki Hayashi
- School of Medical Sciences, Fujita Health University, Toyoake, Aichi, Japan.
| | - Shun Kurata
- School of Medical Sciences, Fujita Health University, Toyoake, Aichi, Japan.,Department of Radiology, Kindai University Hospital, Osakasayama, Osaka, Japan
| | - Yasunori Saito
- School of Medical Sciences, Fujita Health University, Toyoake, Aichi, Japan.,Department of Radiology, Fujita Health University Hospital, Toyoake, Aichi, Japan
| | - Shuta Ogawa
- Department of Radiology, Fujita Health University Hospital, Toyoake, Aichi, Japan
| | - Keisuke Yasui
- School of Medical Sciences, Fujita Health University, Toyoake, Aichi, Japan
| |
Collapse
|
16
|
Tsuruta Y, Nakamura M, Nakata M, Hirashima H, Zhou D, Uto M, Takehana K, Fujimoto T, Mizowaki T. Evaluation of correlation between intrafractional residual setup errors and accumulation of delivered dose distributions in single isocenter volumetric modulated arc therapy for multiple brain metastases. Phys Med 2022; 98:45-52. [DOI: 10.1016/j.ejmp.2022.04.012] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/02/2021] [Revised: 03/30/2022] [Accepted: 04/22/2022] [Indexed: 11/25/2022] Open
|
17
|
Bry V, Saenz D, Pappas E, Kalaitzakis G, Papanikolaou N, Rasmussen K. End to end comparison of surface-guided imaging versus stereoscopic X-rays for the SRS treatment of multiple metastases with a single isocenter using 3D anthropomorphic gel phantoms. J Appl Clin Med Phys 2022; 23:e13576. [PMID: 35322526 PMCID: PMC9121024 DOI: 10.1002/acm2.13576] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Revised: 01/10/2022] [Accepted: 02/12/2022] [Indexed: 01/03/2023] Open
Abstract
INTRODUCTION Two end-to-end tests evaluate the accuracy of a surface-guided radiation therapy (SGRT) system (CRAD Catalyst HD) for position verification in comparison to a stereoscopic x-ray imaging system (Brainlab Exactrac ) for single-isocenter, multiple metastases stereotactic radiosurgery (SRS) using 3D polymer gel inserts. MATERIALS AND METHODS A 3D-printed phantom (Prime phantom, RTsafe PC, Athens, Greece) with two separate cylindrical polymer gel inserts were immobilized in open-face masks and treated with a single isocentric, multitarget SRS plan. Planning was done in Brainlab (Elements) to treat five metastatic lesions in one fraction, and initial setup was done using cone beam computed tomography. Positional verification was done using orthogonal X-ray imaging (Brainlab Exactrac) and/or a surface imaging system (CRAD Catalyst HD, Uppsala, Sweden), and shift discrepancies were recorded for each couch angle. Forty-two hours after irradiation, the gel phantom was scanned in a 1.5 Tesla MRI, and images were fused with the patient computed tomography data/structure set for further analysis of spatial dose distribution. RESULTS Discrepancies between the CRAD Catalyst HD system and Brainlab Exactrac were <1 mm in the translational direction and <0.5° in the angular direction at noncoplanar couch angles. Dose parameters (DMean% , D95% ) and 3D gamma index passing rates were evaluated for both setup modalities for each planned target volume (PTV) at a variety of thresholds: 3%/2 mm (Exactrac≥93.1% and CRAD ≥87.2%), 5%/2 mm (Exactrac≥95.6% and CRAD ≥94.6%), and 5%/1 mm (Exactrac≥81.8% and CRAD ≥83.7%). CONCLUSION Dose metrics for a setup with surface imaging was found to be consistent with setup using x-ray imaging, demonstrating high accuracy and reproducibility for treatment delivery. Results indicate the feasibility of using surface imaging for position verification at noncoplanar couch angles for single-isocenter, multiple-target SRS using end-to-end quality assurance (QA) testing with 3D polymer gel dosimetry.
Collapse
Affiliation(s)
- Victoria Bry
- Department of Radiation OncologyThe University of Texas Health at San AntonioSan AntonioTexasUSA
| | - Daniel Saenz
- Department of Radiation OncologyThe University of Texas Health at San AntonioSan AntonioTexasUSA
| | - Evangelos Pappas
- Department of Biomedical SciencesRadiology and Radiotherapy SectorUniversity of West AtticaAthensGreece
| | | | - Nikos Papanikolaou
- Department of Radiation OncologyThe University of Texas Health at San AntonioSan AntonioTexasUSA
| | - Karl Rasmussen
- Department of Radiation OncologyThe University of Texas Health at San AntonioSan AntonioTexasUSA
| |
Collapse
|
18
|
Pappas EP, Seimenis I, Kouris P, Theocharis S, Lampropoulos KI, Kollias G, Karaiskos P. Target localization accuracy in frame‐based stereotactic radiosurgery: Comparison between MR‐only and MR/CT co‐registration approaches. J Appl Clin Med Phys 2022; 23:e13580. [PMID: 35285583 PMCID: PMC9121047 DOI: 10.1002/acm2.13580] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Revised: 02/17/2022] [Accepted: 02/21/2022] [Indexed: 11/28/2022] Open
Abstract
Purpose In frame‐based Gamma Knife (GK) stereotactic radiosurgery two treatment planning workflows are commonly employed; one based solely on magnetic resonance (MR) images and the other based on magnetic resonance/computed tomography (MR/CT) co‐registered images. In both workflows, target localization accuracy (TLA) can be deteriorated due to MR‐related geometric distortions and/or MR/CT co‐registration uncertainties. In this study, the overall TLA following both clinical workflows is evaluated for cases of multiple brain metastases. Methods A polymer gel‐filled head phantom, having the Leksell stereotactic headframe attached, was CT‐imaged and irradiated by a GK Perfexion unit. A total of 26 4‐mm shots were delivered at 26 locations directly defined in the Leksell stereotactic space (LSS), inducing adequate contrast in corresponding T2‐weighted (T2w) MR images. Prescribed shot coordinates served as reference locations. An additional MR scan was acquired to implement the “mean image” distortion correction technique. The TLA for each workflow was assessed by comparing the radiation‐induced target locations, identified in MR images, with corresponding reference locations. Using T1w MR and CT images of 15 patients (totaling 81 lesions), TLA in clinical cases was similarly assessed, considering MR‐corrected data as reference. For the MR/CT workflow, both global and region of interest (ROI)‐based MR/CT registration approaches were studied. Results In phantom measurements, the MR‐corrected workflow demonstrated unsurpassed TLA (median offset of 0.2 mm) which deteriorated for MR‐only and MR/CT workflows (median offsets of 0.8 and 0.6 mm, respectively). In real‐patient cases, the MR‐only workflow resulted in offsets that exhibit a significant positive correlation with the distance from the MR isocenter, reaching 1.1 mm (median 0.6 mm). Comparable results were obtained for the MR/CT‐global workflow, although a maximum offset of 1.4 mm was detected. TLA was improved with the MR/CT‐ROI workflow resulting in median/maximum offsets of 0.4 mm/1.1 mm. Conclusions Subpixel TLA is achievable in all workflows. For the MR/CT workflow, a ROI‐based MR/CT co‐registration approach could considerably increase TLA and should be preferred instead of a global registration.
Collapse
Affiliation(s)
- Eleftherios P. Pappas
- Medical Physics Laboratory Medical School National and Kapodistrian University of Athens Athens Greece
| | - Ioannis Seimenis
- Medical Physics Laboratory Medical School National and Kapodistrian University of Athens Athens Greece
| | - Panagiotis Kouris
- Medical Physics Laboratory Medical School National and Kapodistrian University of Athens Athens Greece
| | - Stefanos Theocharis
- Medical Physics Laboratory Medical School National and Kapodistrian University of Athens Athens Greece
| | | | - Georgios Kollias
- Medical Physics and Gamma Knife Department Hygeia Hospital Marousi Greece
| | - Pantelis Karaiskos
- Medical Physics Laboratory Medical School National and Kapodistrian University of Athens Athens Greece
| |
Collapse
|
19
|
Tatsumi D. [2. Considerations for Radiation Treatment Planning from Medical Accelerators]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2022; 78:526-530. [PMID: 35598962 DOI: 10.6009/jjrt.2022-2018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
|
20
|
Cui T, Zhou Y, Yue NJ, Vergalasova I, Zhang Y, Zhu J, Nie K. Optimization of treatment isocenter location in single-isocenter LINAC-based stereotactic radiosurgery for management of multiple brain metastases. Med Phys 2021; 48:7632-7640. [PMID: 34655249 DOI: 10.1002/mp.15294] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2021] [Revised: 09/20/2021] [Accepted: 10/06/2021] [Indexed: 11/06/2022] Open
Abstract
PURPOSE Single-isocenter linear accelerator (LINAC)-based stereotactic radiosurgery (SRS) has become a promising treatment technique for the management of multiple brain metastases. Because of the high prescription dose and steep dose gradient, SRS plans are sensitive to geometric errors, resulting in loss of target coverage and suboptimal local tumor control. Current planning techniques rely on adding a uniform and isotropic setup margin to all gross tumor volumes (GTVs) to account for rotational uncertainties. However, this setup margin may be insufficient, since the magnitude of rotational uncertainties varies and is dependent upon the distance between a GTV and the isocenter. In this study, we designed a framework to determine the optimal isocenter of a single-isocenter SRS plan for multiple brain metastases using stochastic optimization to mitigate potential errors resulting from rotational uncertainties. METHODS Planning target volumes (PTVs), defined as GTVs plus a 1-mm margin following common SRS planning convention, were assumed to be originally treated with a prescription dose and therefore covered by the prescription isodose cloud. The dose distribution, including the prescription isodose, was considered invariant assuming small rotations throughout the study. A stochastic optimization scheme was developed to determine the location of the optimal isocenter, so that the prescription dose coverage of rotated GTVs, equivalent to the intersecting volumes between the rotated GTVs and original PTVs, was maximized for any random small rotations about the isocenter. To evaluate the coverage of GTVs, the expected V 100 % undergoing random rotations was approximated as the sample average V 100 % undergoing a predetermined number of rotations. The expected V 100 % of each individual GTV and total GTVs was then compared between the plans using the optimal isocenter and the center-of-mass (CoM), respectively. RESULTS Twenty-two patients previously treated for multiple brain metastases in a single institute were included in this retrospective study. Each patient was initially treated for more than three brain metastases (mean: 7.6; range: 3-15) with the average GTV volume of 0.89 cc (range: 0.03-11.78 cc). The optimal isocenter found for each patient was significantly different from the CoM, with the average Euclidean distance between the optimal isocenter and the CoM being 4.36 ± 2.59 cm. The dose coverage to GTVs was also significantly improved (paired t-test; p < 0.001) when the optimal isocenter was used, with the average V 100 % of total GTVs increasing from 87.1% (standard deviation as std: 11.7%; range: 39.9-98.2%) to 94.2% (std: 5.4%; range: 77.7-99.4%). The volume of a GTV was positively correlated with the expected V 100 % regardless of the isocenter used (Spearman coefficient: ρ = 0.66 ; p < 0.001). The distance between a GTV and the isocenter was negatively correlated with the expected V 100 % when the CoM was used ( ρ = - 0.21 ; p = 0.004), however no significant correlation was found when the optimal isocenter was used ( ρ = - 0.11 ; p = 0.137). CONCLUSION The proposed framework provides an effective approach to determine the optimal isocenter of single-isocenter LINAC-based SRS plans for multiple brain metastases. The implementation of the optimal isocenter results in SRS plans with consistently higher target coverage despite potential rotational uncertainties, and therefore significantly improves SRS plan robustness against random rotational uncertainties.
Collapse
Affiliation(s)
- Taoran Cui
- Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey, New Brunswick, New Jersey, USA
| | - Yongkang Zhou
- Department of Radiation Oncology, Zhongshan Hospital, Shanghai, China
| | - Ning J Yue
- Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey, New Brunswick, New Jersey, USA
| | - Irina Vergalasova
- Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey, New Brunswick, New Jersey, USA
| | - Yin Zhang
- Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey, New Brunswick, New Jersey, USA
| | - Jiahua Zhu
- Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey, New Brunswick, New Jersey, USA
| | - Ke Nie
- Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey, New Brunswick, New Jersey, USA
| |
Collapse
|
21
|
Calmels L, Blak Nyrup Biancardo S, Sibolt P, Nørring Bekke S, Bjelkengren U, Wilken E, Geertsen P, Sjöström D, Behrens CF. Single-isocenter stereotactic non-coplanar arc treatment of 200 patients with brain metastases: multileaf collimator size and setup uncertainties. Strahlenther Onkol 2021; 198:436-447. [PMID: 34528112 PMCID: PMC9038816 DOI: 10.1007/s00066-021-01846-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Accepted: 07/01/2021] [Indexed: 11/24/2022]
Abstract
Purpose The purpose of this study was to evaluate our 2 years’ experience with single-isocenter, non-coplanar, volumetric modulated arc therapy (VMAT) for brain metastasis (BM) stereotactic radiosurgery (SRS). Methods A total of 202 patients treated with the VMAT SRS solution were analyzed retrospectively. Plan quality was assessed for 5 mm (120) and 2.5 mm (high-definition, HD) central leaf width multileaf collimators (MLCs). For BMs at varying distances from the plan isocenter, the geometric offset from the ideal position for two image-guided radiotherapy workflows was calculated. In the workflow with ExacTrac (BrainLAB, München, Germany; W‑ET), patient positioning errors were corrected at each couch rotation. In the workflow without ExacTrac (W-noET), only the initial patient setup correction was considered. The dose variation due to rotational errors was simulated for multiple-BM plans with the HD-MLC. Results Plan conformity and quality assurance were equivalent for plans delivered with the two MLCs while the HD-MLC plans provided better healthy brain tissue (BmP) sparing. 95% of the BMs had residual intrafractional setup errors ≤ 2 mm for W‑ET and 68% for W‑noET. For small BM (≤1 cc) situated >3 cm from the plan isocenter, the dose received by 95% of the BM decreased in median (interquartile range) by 6.3% (2.8–8.8%) for a 1-degree rotational error. Conclusion This study indicates that the HD-MLC is advantageous compared to the 120-MLC for sparing healthy brain tissue. When a 2-mm margin is applied, W‑noET is sufficient to ensure coverage of BM situated ≤ 3 cm of the plan isocenter, while for BM further away, W‑ET is recommended.
Collapse
Affiliation(s)
- Lucie Calmels
- Department of Oncology, Radiotherapy Research Unit (52AA), Herlev & Gentofte Hospital, University of Copenhagen, Borgmester Ib Juuls vej 7, 2730, Herlev, Denmark.
| | - Susan Blak Nyrup Biancardo
- Department of Oncology, Radiotherapy Research Unit (52AA), Herlev & Gentofte Hospital, University of Copenhagen, Borgmester Ib Juuls vej 7, 2730, Herlev, Denmark
| | - Patrik Sibolt
- Department of Oncology, Radiotherapy Research Unit (52AA), Herlev & Gentofte Hospital, University of Copenhagen, Borgmester Ib Juuls vej 7, 2730, Herlev, Denmark
| | - Susanne Nørring Bekke
- Department of Oncology, Radiotherapy Research Unit (52AA), Herlev & Gentofte Hospital, University of Copenhagen, Borgmester Ib Juuls vej 7, 2730, Herlev, Denmark
| | - Ulf Bjelkengren
- Department of Oncology, Radiotherapy Research Unit (52AA), Herlev & Gentofte Hospital, University of Copenhagen, Borgmester Ib Juuls vej 7, 2730, Herlev, Denmark
| | - Eva Wilken
- Department of Oncology, Radiotherapy Research Unit (52AA), Herlev & Gentofte Hospital, University of Copenhagen, Borgmester Ib Juuls vej 7, 2730, Herlev, Denmark
| | - Poul Geertsen
- Department of Oncology, Radiotherapy Research Unit (52AA), Herlev & Gentofte Hospital, University of Copenhagen, Borgmester Ib Juuls vej 7, 2730, Herlev, Denmark
| | - David Sjöström
- Department of Oncology, Radiotherapy Research Unit (52AA), Herlev & Gentofte Hospital, University of Copenhagen, Borgmester Ib Juuls vej 7, 2730, Herlev, Denmark
| | - Claus F Behrens
- Department of Oncology, Radiotherapy Research Unit (52AA), Herlev & Gentofte Hospital, University of Copenhagen, Borgmester Ib Juuls vej 7, 2730, Herlev, Denmark
| |
Collapse
|
22
|
Palmiero AN, Fabian D, Randall ME, Clair W, Pokhrel D. Predicting the effect of indirect cell kill in the treatment of multiple brain metastases via single-isocenter/multitarget volumetric modulated arc therapy stereotactic radiosurgery. J Appl Clin Med Phys 2021; 22:94-103. [PMID: 34498359 PMCID: PMC8504608 DOI: 10.1002/acm2.13400] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Revised: 07/11/2021] [Accepted: 08/04/2021] [Indexed: 12/27/2022] Open
Abstract
Purpose Due to spatial uncertainty, patient setup errors are of major concern for radiosurgery of multiple brain metastases (m‐bm) when using single‐isocenter/multitarget (SIMT) volumetric modulated arc therapy (VMAT) techniques. However, recent clinical outcome studies show high rates of tumor local control for SIMT‐VMAT. In addition to direct cell kill (DCK), another possible explanation includes the effects of indirect cell kill (ICK) via devascularization for a single dose of 15 Gy or more and by inducing a radiation immune intratumor response. This study quantifies the role of indirect cell death in dosimetric errors as a function of spatial patient setup uncertainty for stereotactic treatments of multiple lesions. Material and Methods Nine complex patients with 61 total tumors (2‐16 tumors/patient) were planned using SIMT‐VMAT with geometry similar to HyperArc with a 10MV‐FFF beam (2400 MU/min). Isocenter was placed at the geometric center of all tumors. Average gross tumor volume (GTV) and planning target volume (PTV) were 1.1 cc (0.02–11.5) and 1.9 cc (0.11–18.8) with an average distance to isocenter of 5.4 cm (2.2–8.9). The prescription was 20 Gy to each PTV. Plans were recalculated with induced clinically observable patient setup errors [±2 mm, ±2o] in all six directions. Boolean structures were generated to calculate the effect of DCK via 20 Gy isodose volume (IDV) and ICK via 15 Gy IDV minus the 20 Gy IDV. Contributions of each IDV to the PTV coverage were analyzed along with normal brain toxicity due to the patient setup uncertainty. Induced uncertainty and minimum dose covering the entire PTV were analyzed to determine the maximum tolerable patient setup errors to utilize the ICK effect for radiosurgery of m‐bm via SIMT‐VMAT. Results Patient setup errors of 1.3 mm /1.3° in all six directions must be maintained to achieve PTV coverage of the 15 Gy IDV for ICK. Setup errors of ±2 mm/2° showed clinically unacceptable loss of PTV coverage of 29.4 ± 14.6% even accounting the ICK effect. However, no clinically significant effect on normal brain dosimetry was observed. Conclusions Radiosurgery of m‐bm using SIMT‐VMAT treatments have shown positive clinical outcomes even with small residual patient setup errors. These clinical outcomes, while largely due to DCK, may also potentially be due to the ICK. Potential mechanisms, such as devascularization and/or radiation‐induced intratumor immune enhancement, should be explored to provide a better understanding of the radiobiological response of stereotactic radiosurgery of m‐bm using a SIMT‐VMAT plan.
Collapse
Affiliation(s)
- Allison N Palmiero
- Medical Physics Graduate Program, Department of Radiation Medicine, University of Kentucky, Lexington, Kentucky, USA
| | - Denise Fabian
- Medical Physics Graduate Program, Department of Radiation Medicine, University of Kentucky, Lexington, Kentucky, USA
| | - Marcus E Randall
- Medical Physics Graduate Program, Department of Radiation Medicine, University of Kentucky, Lexington, Kentucky, USA
| | - William Clair
- Medical Physics Graduate Program, Department of Radiation Medicine, University of Kentucky, Lexington, Kentucky, USA
| | - Damodar Pokhrel
- Medical Physics Graduate Program, Department of Radiation Medicine, University of Kentucky, Lexington, Kentucky, USA
| |
Collapse
|
23
|
Skourou C, Hickey D, Rock L, Houston P, Sturt P, O' Sullivan S, Faul C, Paddick I. Treatment of multiple intracranial metastases in radiation oncology: a contemporary review of available technologies. BJR Open 2021; 3:20210035. [PMID: 34877458 PMCID: PMC8611687 DOI: 10.1259/bjro.20210035] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2021] [Accepted: 08/06/2021] [Indexed: 12/31/2022] Open
Abstract
The use of stereotactic radiosurgery to treat multiple intracranial metastases, frequently concurrently, has become increasingly common. The ability to accurately and safely deliver stereotactic radiosurgery treatment to multiple intracranial metastases (MIM) relies heavily on the technology available for targeting, planning, and delivering the dose. A number of platforms are currently marketed for such applications, each with intrinsic capabilities and limitations. These can be broadly categorised as cobalt-based, linac-based, and robotic. This review describes the most common representative technologies for each type along with their advantages and current limitations as they pertain to the treatment of multiple intracranial metastases. Each technology was used to plan five clinical cases selected to represent the clinical breadth of multiple metastases cases. The reviewers discuss the different strengths and limitations attributed to each technology in the case of MIM as well as the impact of disease-specific characteristics (such as total number of intracranial metastases, their size and relative proximity) on plan and treatment quality.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Clare Faul
- St. Luke’s Radiation Oncology Network, Dublin, Ireland
| | - Ian Paddick
- Queen Square Radiosurgery Centre, National Hospital for Neurology and Neurosurgery, London, UK
| |
Collapse
|
24
|
Rojas-López JA, Díaz Moreno RM, Venencia CD. Use of genetic algorithm for PTV optimization in single isocenter multiple metastases radiosurgery treatments with Brainlab Elements™. Phys Med 2021; 86:82-90. [PMID: 34062337 DOI: 10.1016/j.ejmp.2021.05.031] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/04/2021] [Revised: 05/15/2021] [Accepted: 05/22/2021] [Indexed: 11/29/2022] Open
Abstract
PURPOSE To optimize PTV margins for single isocenter multiple metastases stereotactic radiosurgery through a genetic algorithm (GA) that determines the maximum effective displacement of each target (GTV) due to rotations. METHOD 10 plans were optimized. The plans were created with Elements Multiple Mets™ (Brainlab AG, Munchen, Germany) from a predefined template. The mean number of metastases per plan was 5 ± 2 [3,9] and the mean volume of GTV was 1.1 ± 1.3 cc [0.02, 5.1]. PTV margin criterion was based on GTV-isocenter distance and target dimensions. The effective displacement to perform specific rotational combination (roll, pitch, yaw) was optimized by GA. The original plans were re-calculated using the PTV optimized margin and new dosimetric variations were obtained. The Dmean, D99, Paddick conformity index (PCI), gradient index (GI) and dose variations in healthy brain were studied. RESULTS Regarding targets located shorter than 50 mm from the isocenter, the maximum calculated displacement was 2.5 mm. The differences between both PTV margin criteria were statistically significant for Dmean (p = 0.0163), D99 (p = 0.0439), PCI (p = 0.0242), GI (p = 0.0160) and for healthy brain V12 (p = 0.0218) and V10 (p = 0.0264). CONCLUSION The GA allows to determine an optimized PTV margin based on the maximum displacement. Optimized PTV margins reduce the detriment of dosimetric parameters. Greater PTV margins are associated with an increase in healthy brain volume.
Collapse
|
25
|
Woods K, Chin RK, Cook KA, Sheng K, Kishan AU, Hegde JV, Tenn S, Steinberg ML, Cao M. Automated Non-Coplanar VMAT for Dose Escalation in Recurrent Head and Neck Cancer Patients. Cancers (Basel) 2021; 13:cancers13081910. [PMID: 33921062 PMCID: PMC8071369 DOI: 10.3390/cancers13081910] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Revised: 04/05/2021] [Accepted: 04/12/2021] [Indexed: 11/29/2022] Open
Abstract
Simple Summary The ability to escalate the radiation dose to head and neck tumors has been shown to offer improved local control, and consequently, survival for recurrent head and neck cancer (rHNC) patients. This study evaluates the HyperArc automated non-coplanar planning technique (originally developed for intracranial treatment) for 20 rHNC patients, and compares this technique to conventional planning methods. HyperArc enables significant tumor dose escalation, with average increases in mean target dose of over 11.5 Gy (26%), while maintaining clinically-equivalent doses to nearby organs. Our results show that the average probability of tumor control is 23% higher for HyperArc than conventional techniques. Abstract This study evaluates the potential for tumor dose escalation in recurrent head and neck cancer (rHNC) patients with automated non-coplanar volumetric modulated arc therapy (VMAT) stereotactic body radiation therapy (SBRT) planning (HyperArc). Twenty rHNC patients are planned with conventional VMAT SBRT to 40 Gy while minimizing organ-at-risk (OAR) doses. They are then re-planned with the HyperArc technique to match these minimal OAR doses while escalating the target dose as high as possible. Then, we compare the dosimetry, tumor control probability (TCP), and normal tissue complication probability (NTCP) for the two plan types. Our results show that the HyperArc technique significantly increases the mean planning target volume (PTV) and gross tumor volume (GTV) doses by 10.8 ± 4.4 Gy (25%) and 11.5 ± 5.1 Gy (26%) on average, respectively. There are no clinically significant differences in OAR doses, with maximum dose differences of <2 Gy on average. The average TCP is 23% (± 21%) higher for HyperArc than conventional plans, with no significant differences in NTCP for the brainstem, cord, mandible, or larynx. HyperArc can achieve significant tumor dose escalation while maintaining minimal OAR doses in the head and neck—potentially enabling improved local control for rHNC SBRT patients without increased risk of treatment-related toxicities.
Collapse
Affiliation(s)
- Kaley Woods
- Department of Radiation Oncology, University of California, Los Angeles, CA 90095, USA; (K.W.); (R.K.C.); (K.S.); (A.U.K.); (J.V.H.); (S.T.); (M.L.S.)
| | - Robert K. Chin
- Department of Radiation Oncology, University of California, Los Angeles, CA 90095, USA; (K.W.); (R.K.C.); (K.S.); (A.U.K.); (J.V.H.); (S.T.); (M.L.S.)
| | - Kiri A. Cook
- Department of Radiation Oncology, Oregon Health & Science University, Portland, OR 97239, USA;
| | - Ke Sheng
- Department of Radiation Oncology, University of California, Los Angeles, CA 90095, USA; (K.W.); (R.K.C.); (K.S.); (A.U.K.); (J.V.H.); (S.T.); (M.L.S.)
| | - Amar U. Kishan
- Department of Radiation Oncology, University of California, Los Angeles, CA 90095, USA; (K.W.); (R.K.C.); (K.S.); (A.U.K.); (J.V.H.); (S.T.); (M.L.S.)
| | - John V. Hegde
- Department of Radiation Oncology, University of California, Los Angeles, CA 90095, USA; (K.W.); (R.K.C.); (K.S.); (A.U.K.); (J.V.H.); (S.T.); (M.L.S.)
| | - Stephen Tenn
- Department of Radiation Oncology, University of California, Los Angeles, CA 90095, USA; (K.W.); (R.K.C.); (K.S.); (A.U.K.); (J.V.H.); (S.T.); (M.L.S.)
| | - Michael L. Steinberg
- Department of Radiation Oncology, University of California, Los Angeles, CA 90095, USA; (K.W.); (R.K.C.); (K.S.); (A.U.K.); (J.V.H.); (S.T.); (M.L.S.)
| | - Minsong Cao
- Department of Radiation Oncology, University of California, Los Angeles, CA 90095, USA; (K.W.); (R.K.C.); (K.S.); (A.U.K.); (J.V.H.); (S.T.); (M.L.S.)
- Correspondence:
| |
Collapse
|
26
|
Kraft J, van Timmeren JE, Mayinger M, Frei S, Borsky K, Stark LS, Krayenbuehl J, Zamburlini M, Guckenberger M, Tanadini-Lang S, Andratschke N. Distance to isocenter is not associated with an increased risk for local failure in LINAC-based single-isocenter SRS or SRT for multiple brain metastases. Radiother Oncol 2021; 159:168-175. [PMID: 33798610 DOI: 10.1016/j.radonc.2021.03.022] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Revised: 03/07/2021] [Accepted: 03/17/2021] [Indexed: 10/21/2022]
Abstract
PURPOSE To evaluate the impact of the distance between treatment isocenter and brain metastases on local failure in patients treated with a frameless linear-accelerator-based single-isocenter volumetric modulated arc (VMAT) SRS/SRT for multiple brain metastases. METHODS AND MATERIALS Patients treated with SRT for brain metastases (BM) between April 2014 and May 2019 were included in this retrospective study. BM treated with a single-isocenter multiple-target (SIMT) SRT were evaluated for local recurrence-free intervals in dependency to their distance to the treatment isocenter. A Cox-regression model was used to investigate different predictor variables for local failure. Results were compared to patients treated with a single-isocenter-single-target (SIST) approach. RESULTS In total 315 patients with a cumulative number of 1087 BM were analyzed in this study of which 140 patients and 708 BM were treated with SIMT SRS/SRT. Median follow-up after treatment was 13.9 months for SIMT approach and 11.9 months for SIST approach. One-year freedom from local recurrence was 87% and 94% in the SIST and SIMT group, respectively. Median distance to isocenter (DTI) was 4.7 cm (range 0.2-10.5) in the SIMT group. Local recurrence-free interval was not associated with the distance to the isocenter in univariable or multivariable Cox-regression analysis. Multivariable analysis revealed only volume as an independent significant predictor for local failure (p-value <0.05). CONCLUSION SRS/SRT using single-isocenter VMAT for multiple targets achieved high local metastases control rates irrespective of distance to the isocenter, supporting efficacy of single-isocenter stereotactic radiation therapy for multiple brain metastases.
Collapse
Affiliation(s)
- Johannes Kraft
- Department of Radiation Oncology, University Hospital Zurich, University of Zurich, Switzerland; Department of Radiation Oncology, University Hospital Wuerzburg, Germany.
| | - Janita E van Timmeren
- Department of Radiation Oncology, University Hospital Zurich, University of Zurich, Switzerland
| | - Michael Mayinger
- Department of Radiation Oncology, University Hospital Zurich, University of Zurich, Switzerland
| | - Simon Frei
- Department of Radiation Oncology, University Hospital Zurich, University of Zurich, Switzerland
| | - Kim Borsky
- Department of Radiation Oncology, University Hospital Zurich, University of Zurich, Switzerland
| | - Luisa Sabrina Stark
- Department of Radiation Oncology, University Hospital Zurich, University of Zurich, Switzerland
| | - Jerome Krayenbuehl
- Department of Radiation Oncology, University Hospital Zurich, University of Zurich, Switzerland
| | - Mariangela Zamburlini
- Department of Radiation Oncology, University Hospital Zurich, University of Zurich, Switzerland
| | - Matthias Guckenberger
- Department of Radiation Oncology, University Hospital Zurich, University of Zurich, Switzerland
| | - Stephanie Tanadini-Lang
- Department of Radiation Oncology, University Hospital Zurich, University of Zurich, Switzerland
| | - Nicolaus Andratschke
- Department of Radiation Oncology, University Hospital Zurich, University of Zurich, Switzerland
| |
Collapse
|
27
|
Komiyama R, Ohira S, Ueda H, Kanayama N, Masaoka A, Isono M, Ueda Y, Miyazaki M, Teshima T. Intra-fractional patient motion when using the Qfix Encompass immobilization system during HyperArc treatment of patients with brain metastases. J Appl Clin Med Phys 2021; 22:254-260. [PMID: 33656261 PMCID: PMC7984469 DOI: 10.1002/acm2.13143] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2020] [Revised: 11/28/2020] [Accepted: 12/04/2020] [Indexed: 11/12/2022] Open
Abstract
Purpose This study investigated the intra‐fractional motion (IM) of patients immobilized using the QFix Encompass Immobilization System during HyperArc (HA) treatment. Method HA treatment was performed on 89 patients immobilized using the Encompass. The IM during treatment (including megavoltage (MV) registration) was analyzed for six degrees of freedom including three axes of translation (anterior‐posterior, superior‐inferior (SI) and left‐right (LR)) and three axes of rotation (pitch, roll, and yaw). Then, the no corrected IM (IMNC) was retrospectively simulated (excluding MV registration) in three directions (SI, LR, and yaw). Finally, the correlation between the treatment time and the IM of the 3D vector was assessed. Results The average IM in terms of the absolute displacement were 0.3 mm (SI), 0.3 mm (LR) and 0.2° (yaw) for Stereotactic radiosurgery (SRS), and 0.3 mm (SI), 0.2 mm (LR), and 0.2° (yaw) for stereotactic radiotherapy (SRT). The absolute maximum values of IM were <1 mm along the SI and LR axes and <1° along the yaw axis. The absolute maximum displacements for IMNC were >1 mm along the SI and LR axes and >1° along the yaw axis. In the correlation between the treatment time and the IM, the r‐values were −0.025 and 0.027 for SRS and SRT respectively, along the axes of translation. For the axes of rotation, the r‐values were 0.012 and 0.206 for SRS and SRT, respectively. Conclusion Encompass provided patient immobilization with adequate accuracy during HA treatment. The absolute maximum displacement IM was less than IMNC along the translational/rotational axes, and no statistically significant relationship between the treatment time and the IM was observed.
Collapse
Affiliation(s)
- Riho Komiyama
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Shingo Ohira
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan.,Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan
| | - Hikari Ueda
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Naoyuki Kanayama
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Akira Masaoka
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Masaru Isono
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Yoshihiro Ueda
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Masayoshi Miyazaki
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Teruki Teshima
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| |
Collapse
|
28
|
Palmiero AN, Fabian D, St Clair W, Randall M, Pokhrel D. Management of multiple brain metastases via dual-isocenter VMAT stereotactic radiosurgery. Med Dosim 2021; 46:240-246. [PMID: 33549397 DOI: 10.1016/j.meddos.2021.01.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Revised: 01/07/2021] [Accepted: 01/08/2021] [Indexed: 12/27/2022]
Abstract
Single-isocenter volumetric modulated arc therapy (VMAT) stereotactic radiosurgery (SRS) techniques to treat multiple brain metastases simultaneously can significantly improve treatment delivery efficiency, patient compliance, and clinic workflow. However, due to large number of brain metastases sharing the same MLC pair causing island blocking, there is higher low- and intermediate-dose spillage to the normal brain and higher dose to organs-at-risk (OAR). To minimize this problem and improve plan quality, this study proposes a dual-isocenter planning strategy that groups lesions based on hemisphere location (left vs right sided) in the brain parenchyma, providing less island blocking reducing the MLC travel distance. This technique offers simplified planning while also increasing patient comfort and compliance by allowing for large number of brain metastases to be treated in 2 groups. Seven complex patients with 5 to 16 metastases (64 total) were planned with a single-isocenter VMAT-SRS technique using a 10MV-FFF beam with a prescription of 20 Gy to each lesion. The isocenter was placed at the approximate geometric center of the targets. Each patient was replanned using the dual-isocenter approach, generating 2 plans and placing each isocenter at the approximate geometric center of the combined targets of each side with corresponding non-coplanar partial arcs. Compared to single-isocenter VMAT, dual-isocenter VMAT plans provided similar target coverage and dose conformity with less spread of intermediate dose to normal brain with reduction of dose to OAR. Reduction in total monitor units and beam on time was observed, but due to the second isocenter setup and verification, overall treatment time was increased. Dual-isocenter VMAT-SRS planning for multiple brain metastases is a simplified approach that provides superior treatment options for patient compliance who may not tolerate longer traditional treatment times as with individual isocenters to each target. This planning technique significantly reduces the amount of low- and intermediate-dose spillage, further sparing OAR and normal brain, potentially improving target accuracy though localization of left vs right-sided tumors for each isocenter set up.
Collapse
Affiliation(s)
- Allison N Palmiero
- Medical Physics Graduate Program, Department of Radiation Medicine, University of Kentucky, Lexington KY 40536 USA
| | - Denise Fabian
- Medical Physics Graduate Program, Department of Radiation Medicine, University of Kentucky, Lexington KY 40536 USA
| | - William St Clair
- Medical Physics Graduate Program, Department of Radiation Medicine, University of Kentucky, Lexington KY 40536 USA
| | - Marcus Randall
- Medical Physics Graduate Program, Department of Radiation Medicine, University of Kentucky, Lexington KY 40536 USA
| | - Damodar Pokhrel
- Medical Physics Graduate Program, Department of Radiation Medicine, University of Kentucky, Lexington KY 40536 USA.
| |
Collapse
|
29
|
Tsuruta Y, Nakata M, Nakamura M, Uto M, Takehana K, Hirashima H, Fujimoto T, Mizowaki T. Evaluation of intrafractional head motion for intracranial stereotactic radiosurgery with a thermoplastic frameless mask and ceiling-floor-mounted image guidance device. Phys Med 2021; 81:245-252. [PMID: 33485142 DOI: 10.1016/j.ejmp.2020.12.019] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Revised: 12/17/2020] [Accepted: 12/25/2020] [Indexed: 10/22/2022] Open
Abstract
PURPOSE To evaluate intrafractional head motion (IFM) in patients who underwent intracranial stereotactic radiosurgery with the ExacTrac X-ray system (ETX) and a frameless mask. METHODS A total of 143 patients who completed a pre-treatment examination for IFM were eligible for this study. The frameless mask type B R408 (Klarity Medical & Equipment Co., Ltd., Guangzhou, China), which covers the back of the head, and the entire face, was used for patient immobilization. After the initial 6D correction and first X-ray verification (IFM1), X-ray verification was performed every 3 min for a duration of 15 min. The IFMp (2 ≤ p ≤ 6) was calculated as the positional difference from IFM1. In addition, the inter-phase IFM (IP-IFM) and IFMm were calculated. The IP-IFM was defined as |IFMp - IFMp-1|, and IFMm as the difference between the values after all patients were asked to move their heads intentionally with the frameless mask on. RESULTS Both translational IFMp and IP-IFM exceeded 1 mm for a single patient, whereas, for all patients, the translational IFMm values were kept to within 1 mm in all directions. The proportions of the rotational IFMp, IP-IFM, and IFMm values within 0.5° were greater than 94.4%, 98.6%, and 90.2% for all of the rotational axes, respectively. CONCLUSIONS A frameless mask achieved highly accurate patient positioning in combination with ETX and a 6°-of-freedom robotic couch; however, a deviation over 1 mm and 0.5° was observed with low frequency. Therefore, X-ray verification and correction are required during treatment.
Collapse
Affiliation(s)
- Yusuke Tsuruta
- Division of Clinical Radiology Service, Kyoto University Hospital, Kyoto 606-8507, Japan; Division of Medical Physics, Department of Information Technology and Medical Engineering, Human Health Sciences, Graduate School of Medicine, Kyoto University, Kyoto 606-8507, Japan
| | - Manabu Nakata
- Division of Clinical Radiology Service, Kyoto University Hospital, Kyoto 606-8507, Japan
| | - Mitsuhiro Nakamura
- Division of Medical Physics, Department of Information Technology and Medical Engineering, Human Health Sciences, Graduate School of Medicine, Kyoto University, Kyoto 606-8507, Japan; Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto 606-8507, Japan.
| | - Megumi Uto
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto 606-8507, Japan
| | - Keiichi Takehana
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto 606-8507, Japan
| | - Hideaki Hirashima
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto 606-8507, Japan
| | - Takahiro Fujimoto
- Division of Clinical Radiology Service, Kyoto University Hospital, Kyoto 606-8507, Japan
| | - Takashi Mizowaki
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto 606-8507, Japan
| |
Collapse
|
30
|
Nakano H, Tanabe S, Yamada T, Utsunomiya S, Takizawa T, Sakai M, Sasamoto R, Sakai H, Nakano T, Saito H, Ohta A, Kaidu M, Ishikawa H. Maximum distance in single-isocenter technique of stereotactic radiosurgery with rotational error using margin-based analysis. Radiol Phys Technol 2021; 14:57-63. [PMID: 33393057 DOI: 10.1007/s12194-020-00602-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2020] [Revised: 12/02/2020] [Accepted: 12/07/2020] [Indexed: 12/11/2022]
Abstract
Through geometrical simulation, we evaluated the effect of rotational error in patient setup on geometrical coverage and calculated the maximum distance between the isocenter and target, where the clinical PTV margin secures geometrical coverage with a single-isocenter technique. We used simulated spherical GTVs with diameters of 1.0 (GTV 1), 1.5 (GTV 2), 2.0 (GTV 3), and 3.0 cm (GTV 4). The location of the target center was set such that the distance between the target and isocenter ranged from 0 to 15 cm. We created geometrical coverage vectors so that each target was entirely covered by 100% of the prescribed dose. The vectors of the target positions were simultaneously rotated within a range of 0°-2.0° around the x-, y-, and z-axes. For each rotational error, the reduction in geometrical coverage of the targets was calculated and compared with that obtained for a rotational error of 0°. The tolerance value of the geometrical coverage reduction was defined as 5% of the GTV. The maximum distance that satisfied the 5% tolerance value for different values of rotational error at a clinical PTV margin of 0.1 cm was calculated. When the rotational errors were 0.5° for a 0.1 cm PTV margin, the maximum distances were as follows: GTV 1: 7.6 cm; GTV 2: 10.9 cm; GTV 3: 14.3 cm; and GTV 4: 21.4 cm. It might be advisable to exclude targets that are > 7.6 cm away from the isocenter with a single-isocenter technique to satisfy the tolerance value for all GTVs.
Collapse
Affiliation(s)
- Hisashi Nakano
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, 1-757 Asahimachi-dori, Chuo-ku, Niigata, Japan.
| | - Satoshi Tanabe
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, 1-757 Asahimachi-dori, Chuo-ku, Niigata, Japan
| | - Takumi Yamada
- Section of Radiology, Department of Clinical Support, Niigata University Medical and Dental Hospital, 1-757 Asahimachi-dori, Chuo-ku, Niigata, Japan
| | - Satoru Utsunomiya
- Department of Radiological Technology, Niigata University Graduate School of Health Sciences, 2-746 Asahimachi-dori, Chuo-ku, Niigata, Japan
| | - Takeshi Takizawa
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, 1-757 Asahimachi-dori, Chuo-ku, Niigata, Japan.,Department of Radiation Oncology, Niigata Neurosurgical Hospital, Yamada, Nishi-ku, Niigata, 3057, Japan
| | - Madoka Sakai
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, 1-757 Asahimachi-dori, Chuo-ku, Niigata, Japan
| | - Ryuta Sasamoto
- Department of Radiological Technology, Niigata University Graduate School of Health Sciences, 2-746 Asahimachi-dori, Chuo-ku, Niigata, Japan
| | - Hironori Sakai
- Section of Radiology, Department of Clinical Support, Niigata University Medical and Dental Hospital, 1-757 Asahimachi-dori, Chuo-ku, Niigata, Japan
| | - Toshimichi Nakano
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, 1-757 Asahimachi-dori, Chuo-ku, Niigata, Japan
| | - Hirotake Saito
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, 1-757 Asahimachi-dori, Chuo-ku, Niigata, Japan
| | - Atsushi Ohta
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, 1-757 Asahimachi-dori, Chuo-ku, Niigata, Japan
| | - Motoki Kaidu
- Department of Radiology and Radiation Oncology, Niigata University Graduate School of Medical and Dental Sciences, 1-757 Asahimachi-dori, Chuo-ku, Niigata, Japan
| | - Hiroyuki Ishikawa
- Department of Radiology and Radiation Oncology, Niigata University Graduate School of Medical and Dental Sciences, 1-757 Asahimachi-dori, Chuo-ku, Niigata, Japan
| |
Collapse
|
31
|
Ohira S, Kanayama N, Komiyama R, Ikawa T, Toratani M, Ueda Y, Washio H, Miyazaki M, Koizumi M, Teshima T. Intra-fractional patient setup error during fractionated intracranial stereotactic irradiation treatment of patients wearing medical masks: comparison with and without bite block during COVID-19 pandemic. JOURNAL OF RADIATION RESEARCH 2021; 62:163-171. [PMID: 33392618 PMCID: PMC7717301 DOI: 10.1093/jrr/rraa101] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/05/2020] [Revised: 07/22/2020] [Indexed: 05/14/2023]
Abstract
The immobilization of patients with a bite block (BB) carries the risk of interpersonal infection, particularly in the context of pandemics such as COVID-19. Here, we compared the intra-fractional patient setup error (intra-SE) with and without a BB during fractionated intracranial stereotactic irradiation (STI). Fifteen patients with brain metastases were immobilized using a BB without a medical mask, while 15 patients were immobilized without using a BB and with a medical mask. The intra-SEs in six directions (anterior-posterior (AP), superior-inferior (SI), left-right (LR), pitch, roll, and yaw) were calculated by using cone-beam computed tomography images acquired before and after the treatments. We analyzed a total of 53 and 67 treatment sessions for the with- and without-BB groups, respectively. A comparable absolute mean translational and rotational intra-SE was observed (P > 0.05) in the AP (0.19 vs 0.23 mm with- and without-BB, respectively), SI (0.30 vs 0.29 mm), LR (0.20 vs 0.29 mm), pitch (0.18 vs 0.27°), roll (0.23 vs 0.23°) and yaw (0.27 vs 22°) directions. The resultant planning target volume (PTV) margin to compensate for intra-SE was <1 mm. No statistically significant correlation was observed between the intra-SE and treatment times. A PTV margin of <1 mm was achieved even when patients were immobilized without a BB during STI dose delivery.
Collapse
Affiliation(s)
- Shingo Ohira
- Corresponding author. Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, 537-8567 Osaka, Japan. Tel: +81-6-6945-1181; Fax: +81-6-6945-1900;
| | - Naoyuki Kanayama
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Riho Komiyama
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Toshiki Ikawa
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Masayasu Toratani
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Yoshihiro Ueda
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Hayate Washio
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Masayoshi Miyazaki
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Masahiko Koizumi
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan
| | - Teruki Teshima
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| |
Collapse
|
32
|
Parikh NR, Kundu P, Levin-Epstein R, Chang EM, Agazaryan N, Hegde JV, Steinberg ML, Tenn SE, Kaprealian TB. Time-Driven Activity-Based Costing Comparison of Stereotactic Radiosurgery to Multiple Brain Lesions Using Single-Isocenter Versus Multiple-Isocenter Technique. Int J Radiat Oncol Biol Phys 2020; 108:999-1007. [PMID: 32603774 DOI: 10.1016/j.ijrobp.2020.06.035] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2020] [Revised: 04/30/2020] [Accepted: 06/22/2020] [Indexed: 11/29/2022]
Abstract
PURPOSE Stereotactic radiosurgery (SRS) historically has been used to treat multiple brain lesions using a multiple-isocenter technique-frequently associated with significant complexity in treatment planning and long treatment times. Recently, given innovations in planning algorithms, patients with multiple brain lesions may now be treated with a single-isocenter technique using fewer total arcs and less time spent during image guidance (though with stricter image guided radiation therapy tolerances). This study used time-driven activity-based costing to determine the difference in cost to a provider for delivering SRS to multiple brain lesions using single-isocenter versus multiple-isocenter techniques. METHODS AND MATERIALS Process maps, consisting of discrete steps, were created for each phase of the SRS care cycle and were based on interviews with department personnel. Actual treatment times (including image guidance) were extracted from treatment record and verify software. Additional sources of data to determine costs included salary/benefit data of personnel and average list price/maintenance costs for equipment. RESULTS Data were collected for 22 patients who underwent single-isocenter SRS (mean lesions treated, 5.2; mean treatment time, 30.2 minutes) and 51 patients who underwent multiple-isocenter SRS (mean lesions treated, 4.4; mean treatment time, 75.2 minutes). Treatment time for multiple-isocenter SRS varied substantially with increasing number of lesions (11.8 minutes/lesion; P < .001), but to a much lesser degree in single-isocenter SRS (1.8 minutes/lesion; P = .029). The resulting cost savings from single-isocenter SRS based on number of lesions treated ranged from $296 to $3878 for 2 to 10 lesions treated. The 2-mm planning treatment volume margin used with single-isocenter SRS resulted in a mean 43% increase of total volume treated compared with a 1-mm planning treatment volume expansion. CONCLUSIONS In a comparison of time-driven activity-based costing assessment of single-isocenter versus multiple-isocenter SRS for multiple brain lesions, single-isocenter SRS appears to save time and resources for as few as 2 lesions, with incremental benefits for additional lesions treated.
Collapse
Affiliation(s)
- Neil R Parikh
- Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California
| | - Palak Kundu
- Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California
| | - Rebecca Levin-Epstein
- Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California
| | - Eric M Chang
- Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California
| | - Nzhde Agazaryan
- Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California
| | - John V Hegde
- Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California
| | - Michael L Steinberg
- Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California
| | - Stephen E Tenn
- Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California
| | - Tania B Kaprealian
- Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California.
| |
Collapse
|
33
|
Barnes M, Yeo A, Thompson K, Phillips C, Kron T, Hardcastle N. A retrospective analysis of setup and intrafraction positional variation in stereotactic radiotherapy treatments. J Appl Clin Med Phys 2020; 21:109-119. [PMID: 33140915 PMCID: PMC7769413 DOI: 10.1002/acm2.13076] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2020] [Revised: 09/10/2020] [Accepted: 09/25/2020] [Indexed: 01/11/2023] Open
Abstract
PURPOSE The aim of this study was to provide a comprehensive assessment of patient intrafraction motion in linac-based frameless stereotactic radiosurgery (SRS) and radiotherapy (SRT). METHODS A retrospective review was performed on 101 intracranial SRS/SRT patients immobilized with the Klarity stereotactic thermoplastic mask (compatible with the Brainlab frameless stereotactic system) and aligned on a 6 Degree of Freedom (DoF) couch with the Brainlab ExacTrac image guidance system. Both pretreatment and intrafraction correction data are provided as observed by the ExacTrac system. The effects of couch angle and treatment duration on positioning outcomes are also explored. RESULTS Initial setup data for patients is shown to vary by up to ±4.18 mm, ±2.97°, but when corrected with a single x-ray image set with ExacTrac, patient positions are corrected to within ±2.11 mm, ±2.27°. Intrafraction patient motion is shown to be uniformly random and independent of both time and couch angle. Patient motion was also limited to within approximately 3 mm, 3° by the thermoplastic mask. CONCLUSIONS Our results indicate that since patient intrafraction motion is unrelated to couch rotation and treatment duration, intrafraction patient monitoring in 6 DoF is required to minimize intracranial SRS/SRT margins.
Collapse
Affiliation(s)
- Micah Barnes
- Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia.,Imaging and Medical Beamline, Australian Nuclear Science and Technology Organisation - Australian Synchrotron, Clayton, VIC, Australia
| | - Adam Yeo
- Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia.,School of Science, RMIT University, Melbourne, VIC, Australia
| | - Kenton Thompson
- Department of Radiation Therapy Services, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia
| | - Claire Phillips
- Department of Radiation Oncology, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia
| | - Tomas Kron
- Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia.,Sir Peter MacCallum Department of Oncology, The University of Melbourne, Melbourne, VIC, Australia.,Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, Australia
| | - Nicholas Hardcastle
- Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia.,Sir Peter MacCallum Department of Oncology, The University of Melbourne, Melbourne, VIC, Australia.,Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, Australia
| |
Collapse
|
34
|
Palmiero AN, Critchfield L, St Clair W, Randall M, Pokhrel D. Single-Isocenter Volumetric Modulated Arc Therapy (VMAT) Radiosurgery for Multiple Brain Metastases: Potential Loss of Target(s) Coverage Due to Isocenter Misalignment. Cureus 2020; 12:e11267. [PMID: 33274143 PMCID: PMC7707911 DOI: 10.7759/cureus.11267] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2020] [Accepted: 10/30/2020] [Indexed: 01/08/2023] Open
Abstract
Purpose A single-isocenter volumetric modulated arc therapy (VMAT) treatment to multiple brain metastatic patients is an efficient stereotactic radiosurgery (SRS) option. However, the current clinical practice of single-isocenter SRS does not account for patient setup uncertainty, which degrades treatment delivery accuracy. This study quantifies the loss of target coverage and potential collateral dose to normal tissue due to clinically observable isocenter misalignment. Methods and materials Nine patients with 61 total tumors (2-16 tumors/patient) who underwent Gamma Knife® SRS were replanned in Eclipse™ using 10 megavoltages (MV) flattening-filter-free (FFF) bream (2400 MU/min), using a single-isocenter VMAT plan, similar to HyperArc™ VMAT plan. Isocenter was placed in the geometric center of the tumors. The prescription was 20 Gy to each tumor. Average gross tumor volume (GTV) and planning target volume (PTV) were 1.1 cc (0.02-11.5 cc) and 1.9 cc (0.11-18.8 cc), respectively, derived from MRI images. The average isocenter to tumor distance was 5.5 cm (1.6-10.1 cm). Six-degrees of freedom (6DoF) random and systematic residual set up errors within [±2 mm, ±2o] were generated using an in-house script in Eclipse based on our pre-treatment daily cone-beam CT imaging shifts and recomputed for the simulated VMAT plan. Relative loss of target coverage as a function of tumor size and distance to isocenter were evaluated as well as collateral dose to organs-at risk (OAR). Results The average beam-on time was less than six minutes. However, loss of target coverage for clinically observable setup errors were, on average, 7.9% (up to 73.1%) for the GTV (p < 0.001) and 21.5% for the PTV (up to 93.7%; p < 0.001). The correlation was found for both random and systematic residual setup errors with tumor sizes; there was a greater loss of target coverage for small tumors. Due to isocenter misalignment, OAR doses fluctuated and potentially receive higher doses than the original plan. Conclusion A single-isocenter VMAT SRS treatment (similar to HyperArc™ VMAT) to multiple brain metastases was fast with < 6 min of beam-on time. However, due to small residual set up errors, single-isocenter VMAT, in its current use, is not an accurate SRS treatment modality for multiple brain metastases. Loss of target coverage was statistically significant, especially for smaller lesions, and may not be clinically acceptable if left uncorrected. Further investigation of correction strategies is underway.
Collapse
Affiliation(s)
| | | | | | - Marcus Randall
- Radiation Medicine, University of Kentucky, Lexington, USA
| | | |
Collapse
|
35
|
Slagowski JM, Wen Z. Selection of single-isocenter for multiple-target stereotactic brain radiosurgery to minimize total margin volume. Phys Med Biol 2020; 65:185012. [PMID: 32460254 DOI: 10.1088/1361-6560/ab9703] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Treating multiple brain metastases with a single isocenter improves efficiency but requires margins to account for rotation induced shifts that increase with target-to-isocenter distance. A method to select the single isocenter position that minimizes the total volume of normal tissue treated during multi-target stereotactic radiosurgery (SRS) is presented. A statistical framework was developed to quantify the impact of uncertainties on planning target volumes (PTV). Translational and rotational shifts were modeled with independent, zero mean, Gaussian distributions in three dimensions added in quadrature. The standard deviations of errors were varied from 0.5-2.0 mm and 0.5°-2.0°. The volume of normal tissue treated due to margin expansions required to maintain a 95% probability of target coverage was computed. Tumors were modeled as 4-40 mm diameter spheres. Target separation distance was varied from 40-100 mm for two- and three-lesion scenarios. The percent increase in PTV was determined relative to an isocenter at the geometric centroid of the targets for the optimal isocenter that minimized the total normal tissue treated, and isocenters at the center-of-mass (COM) and center-of-surface-area (CSA). For two targets, isocenter placement at the optimal location, COM, and CSA, reduced the total margin versus an isocenter at midline up to 17.8%, 17.7%, and 17.8%, respectively, for 0.5 mm and 0.5° errors. For three targets, optimal isocenter placement reduced the margin volume up to 21%, 19%, and 14%, for uncertainties of (0.5 mm, 0.5°), (1.0 mm, 1.0°), and (2.0 mm, 2.0°), respectively. COM and CSA provide useful approximations to select the optimal isocenter for multi-target single-isocenter SRS for two or three targets with maximum dimensions ⩽ 40 mm and separation distances ⩽ 100 mm when uncertainties are ⩽ 1.0 mm and ⩽ 1.0°. CSA provides a more accurate approximation than COM. Optimal treatment isocenter selection for multiple targets of large size differences can significantly reduce total margin volume.
Collapse
Affiliation(s)
- Jordan M Slagowski
- Department of Radiation and Cellular Oncology, University of Chicago, Chicago, IL, United States of America. Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX, United States of America
| | | |
Collapse
|
36
|
Taylor M, Williams J, Gleason JF. Effects of Multileaf Collimator Design and Function When Using an Optimized Dynamic Conformal Arc Approach for Stereotactic Radiosurgery Treatment of Multiple Brain Metastases With a Single Isocenter: A Planning Study. Cureus 2020; 12:e9833. [PMID: 32832305 PMCID: PMC7437117 DOI: 10.7759/cureus.9833] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2020] [Accepted: 08/17/2020] [Indexed: 12/11/2022] Open
Abstract
Background Stereotactic radiosurgery (SRS) or fractionated SRS (fSRS) are effective options for the treatment of brain metastases. When treating multiple metastases with a linear accelerator-based approach, a single isocenter allows for efficient treatment delivery. In this study, we present our findings comparing dosimetric parameters of Brainlab (Munich, Germany) Elements™ Multiple Brain Mets SRS (MME) software (version 1.5 versus version 2.0) for a variety of scenarios and patients. The impact of multileaf collimator design and function on plan quality within the software was also evaluated. Materials and methods Twenty previously treated patients with a total of 58 lesions (from one to seven lesions each) were replanned with an updated version of the multiple brain Mets software solution. For each plan, the mean conformity index (CI), mean gradient index (GI), the volume of normal brain receiving 12 Gy (V12), and mean brain dose were evaluated. Additionally, all v2.0 plans were further evaluated with jaw tracking for by Elekta (Stockholm, Sweden) and HD120™ multileaf collimator by Varian Medical Systems (Palo Alto, USA). Results The new software version demonstrated improvements for CI, GI and V12 (p <0.01). For the Elekta Agility™ multileaf collimator, jaw tracking improved all dosimetric parameters except for CI (p =0.178) and mean brain dose (p =0.93). For the Varian with HD120 multileaf collimator, all parameters improved. Conclusions The software enhancements in v2.0 of the software provided improvements in planning efficiency and dosimetric parameters. Differences in multileaf collimator design may provide an additional incremental benefit in a subset of clinical scenarios.
Collapse
Affiliation(s)
| | | | - John F Gleason
- Radiation Oncology, Alliance Cancer Care, Huntsville, USA
| |
Collapse
|
37
|
Prentou G, Pappas EP, Logothetis A, Koutsouveli E, Pantelis E, Papagiannis P, Karaiskos P. Dosimetric impact of rotational errors on the quality of VMAT-SRS for multiple brain metastases: Comparison between single- and two-isocenter treatment planning techniques. J Appl Clin Med Phys 2020; 21:32-44. [PMID: 32022447 PMCID: PMC7075408 DOI: 10.1002/acm2.12815] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2019] [Revised: 11/21/2019] [Accepted: 12/10/2019] [Indexed: 12/22/2022] Open
Abstract
Purpose In the absence of a 6D couch and/or assuming considerable intrafractional patient motion, rotational errors could affect target coverage and OAR‐sparing especially in multiple metastases VMAT‐SRS cranial cases, which often involve the concurrent irradiation of off‐axis targets. This work aims to study the dosimetric impact of rotational errors in such applications, under a comparative perspective between the single‐ and two‐isocenter treatment techniques. Methods Ten patients (36 metastases) were included in this study. Challenging cases were only considered, with several targets lying in close proximity to OARs. Two multiarc VMAT plans per patient were prepared, involving one and two isocenters, serving as the reference plans. Different degrees of angular offsets at various orientations were introduced, simulating rotational errors. Resulting dose distributions were evaluated and compared using commonly employed dose‐volume and plan quality indices. Results For single‐isocenter plans and 1⁰ rotations, plan quality indices, such as coverage, conformity index and D95%, deteriorated significantly (>5%) for distant targets from the isocenter (at> 4–6 cm). Contrarily, for two‐isocenter plans, target distances to nearest isocenter were always shorter (≤4 cm), and, consequently, 1⁰ errors were well‐tolerated. In the most extreme case considered (2⁰ around all axes) conformity index deteriorated by on‐average 7.2%/cm of distance to isocenter, if one isocenter is used, and 2.6%/cm, for plans involving two isocenters. The effect is, however, strongly associated with target volume. Regarding OARs, for single‐isocenter plans, significant increase (up to 63%) in Dmax and D0.02cc values was observed for any angle of rotation. Plans that could be considered clinically unacceptable were obtained even for the smallest angle considered, although rarer for the two‐isocenter planning approach. Conclusion Limiting the lesion‐to‐isocenter distance to ≤4 cm by introducing additional isocenter(s) appears to partly mitigate severe target underdosage, especially for smaller target sizes. If OAR‐sparing is also a concern, more stringent rotational error tolerances apply.
Collapse
Affiliation(s)
- Georgia Prentou
- Medical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, Athens, Greece
| | - Eleftherios P Pappas
- Medical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, Athens, Greece
| | - Andreas Logothetis
- Medical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, Athens, Greece
| | | | - Evaggelos Pantelis
- Medical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, Athens, Greece
| | - Panagiotis Papagiannis
- Medical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, Athens, Greece
| | - Pantelis Karaiskos
- Medical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, Athens, Greece
| |
Collapse
|