Callens D, Benazzouz C, Stessens L, Piot W, Nulens A, Lambrecht M, Berkovic P, Daisne JF. A prospective randomized study comparing two frameless immobilization systems for cranial stereotactic radiotherapy. Tech Innov Patient Support Radiat Oncol 2024; 30:100249. [PMID: 38623575 PMCID: PMC11017338 DOI: 10.1016/j.tipsro.2024.100249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Revised: 03/14/2024] [Accepted: 04/02/2024] [Indexed: 04/17/2024] Open
Abstract
Introduction The Dual Shell Encompass Fibreplast™ System (DS-Encompass) by CQ Medical™ is validated for frameless immobilization in stereotactic brain radiotherapy. An alternative mask model has been proposed with the rear shell replaced by a Moldcare® cushion (M-Encompass). To validate the use of this model in our cranial stereotactic workflow method including HyperArc™, we performed a prospective randomized study comparing inter-and intrafractional motion and patients comfort between both masks. Materials & Methods A prospective randomized study between DS-Encompass and M-Encompass was conducted involving 60 participants. Stratification between DS-Encompass and M-Encompass was carried out based on the fractionation scheme. Treatment plans were created with HyperArc™. During treatment, surface guidance was used for patient positioning and monitoring. A pre-treatment cone-beam CT (CBCT) was acquired to correct interfractional motion and a post-treatment CBCT was acquired to quantify the intrafractional motion. Patients reported comfort was analyzed with a Likert-scale at the end of the treatment. Unpaired t-tests were conducted to determine the level of significance. Results No significant difference in interfractional translations is present. A significant difference is revealed in roll-axis rotation, where DS-Encompass allows for smaller deviations. Since interfractional motion can be corrected through daily CBCT-scans and 6D-couch corrections, they are clinically irrelevant. Intrafractional motion does not differ significantly and remains below 0.5 mm and 0.5° for both systems. There is no statistical difference in patient-reported comfort. Conclusion We conclude that Encompass with Moldcare offers a safe alternative to Duall Shell Encompass for non-coplanar stereotactic brain radiotherapy. There is no significant difference in intrafractional motion nor difference in comfort levels.
Collapse
Affiliation(s)
- Dylan Callens
- Laboratory of Experimental Radiotherapy, Catholic University of Leuven, Leuven, Belgium
- Department of Radiation Oncology, University Hospitals of Leuven, Leuven, Belgium
| | - Chahrazad Benazzouz
- Department of Radiation Oncology, University Hospitals of Leuven, Leuven, Belgium
| | - Lise Stessens
- Department of Radiation Oncology, University Hospitals of Leuven, Leuven, Belgium
| | - Wout Piot
- Department of Radiation Oncology, University Hospitals of Leuven, Leuven, Belgium
| | - An Nulens
- Department of Radiation Oncology, University Hospitals of Leuven, Leuven, Belgium
| | - Maarten Lambrecht
- Laboratory of Experimental Radiotherapy, Catholic University of Leuven, Leuven, Belgium
- Department of Radiation Oncology, University Hospitals of Leuven, Leuven, Belgium
- Leuven Cancer Institute (LKI), Leuven, Belgium
| | - Patrick Berkovic
- Laboratory of Experimental Radiotherapy, Catholic University of Leuven, Leuven, Belgium
- Department of Radiation Oncology, University Hospitals of Leuven, Leuven, Belgium
| | - Jean-François Daisne
- Laboratory of Experimental Radiotherapy, Catholic University of Leuven, Leuven, Belgium
- Department of Radiation Oncology, University Hospitals of Leuven, Leuven, Belgium
- Leuven Cancer Institute (LKI), Leuven, Belgium
| |
Collapse
|
2
|
Kang CL, Huang YY, Chen YR, Tsai SH, Huang CC, Huang YJ. Patient Cranial Angle and Intrafractional Stability in CyberKnife Robotic Radiosurgery: A Retrospective Analysis. Technol Cancer Res Treat 2024; 23:15330338241235058. [PMID: 38460959 PMCID: PMC10924736 DOI: 10.1177/15330338241235058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Revised: 01/22/2024] [Accepted: 02/08/2024] [Indexed: 03/11/2024] Open
Abstract
Purpose: The aim of this study was to investigate whether variations in cranial angles and treatment accuracy during CyberKnife robotic radiosurgery necessitate adjustment of the margins of the planning target volume. Patients and Methods: Data from 66 patients receiving CyberKnife treatment for brain tumors were retrospectively analyzed. Patients were immobilized using a thermoplastic mask and headrest. The cranial angle was measured on planning CT and patients were divided into 2 groups: ≤10° (Group A) and >10° (Group B). Intrafractional motion was recorded using the CyberKnife tracking system over 50 min. Translational and rotational errors were compared between groups, and planning target volume margins were calculated. Results: In Group A, significant translational error differences were found along with the X-axis over time (P < .02). In Group B, significant differences occurred along with the Z-axis (P < .03). No significant rotational or 3-dimensional vector differences were found in either group. Group A had significantly lower Y-axis (P < .045) and roll axis (P < .005) errors compared to Group B. Estimated planning target volume margins in Group A were 0.56 mm (X), 0.46 mm (Y), and 0.47 mm (Z). In Group B, margins were 0.62 mm (X), 0.48 mm (Y), and 0.46 mm (Z). Margins covering 95% of intrafraction motion were 0.49 to 0.50 mm (X, Y, Z) and 0.69 mm (3-dimensional vector) for Group A, and 0.48 to 0.60 mm and 0.79 mm for Group B. With a 1-mm margin, complete coverage was achieved in Group A while 2.1% of vectors in Group B exceeded 1 mm. Conclusion: Adjusting cranial angle to ≤10° during thermoplastic mask molding provided better or similar intrafractional stability compared to >10°.
Collapse
Affiliation(s)
- Chen-Lin Kang
- Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan
- Department of Medical Imaging and Radiology, Shu-Zen Junior College of Medicine and Management, Kaohsiung, Taiwan
| | - Ya-Yu Huang
- Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan
| | - Yi-Ren Chen
- Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan
| | - Shu-Huei Tsai
- Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan
| | - Chun-Chieh Huang
- Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan
- Graduate Institute of Clinical Medical Sciences, College of Medicine, Chang Gung University, Taoyuan, Taiwan
| | - Yu-Jie Huang
- Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan
| |
Collapse
|
3
|
Li F, Mail N, Stefania diMayorca M, McCaw TJ, Ozhasoglu C, Lalonde R, Chang J, Huq MS. Single isocenter HyperArc treatment of multiple intracranial metastases: Targeting accuracy. J Appl Clin Med Phys 2024; 25:e14234. [PMID: 38059673 PMCID: PMC10795440 DOI: 10.1002/acm2.14234] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2023] [Revised: 10/12/2023] [Accepted: 10/25/2023] [Indexed: 12/08/2023] Open
Abstract
PURPOSE/OBJECTIVES (A) To examine the alignment accuracy of CBCT guidance for brain metastases with off centered isocenters, (B) to test dose delivery and targeting accuracy for single isocenter treatments with multiple brain metastases. We report the results of the end-to-end test for Truebeam stereotactic radiosurgery (SRS). MATERIALS/METHODS An anthropomorphic CT head phantom was drilled with five MOSFET inserts and two PTW Pinpoint chamber inserts. The phantom was simulated, planned, and delivered. For the purpose of comparing the accuracy of alignment, CBCTs were acquired with the isocenter centered and offset superiorly 8 cm, inferiorly 8 cm, anteriorly 7 cm, posteriorly 7 cm, and right 5 cm. There were six degrees of freedom corrections applied to the plans, as well as intentional rotational and translational errors for dose comparisons. Dose accuracy checks were performed with MOSFET and PTW Pinpoint chamber, and targeting accuracy was assessed with GafChromic films. RESULT (A) Compared to centered CBCT, off-centered CBCT scan showed some alignment errors, with a maximum difference of 0.6-degree pitch and 0.9 mm translation when the phantom was placed 8 cm inferior off center. (B) For the single isocenter plan, measured doses of the five MOSFET were 95%-100% of the planned dose, whereas the multiple isocenter plans were 96%-100%. With intentional setup errors of 1-degree pitch, doses were 97.1%-100.4% compared to the perfect setup. The same was found for the two pinpoint chamber readings with 1-degree rotation and 1 mm translation. (C) Targeting accuracy for targets at the isocenter is 0.67 mm, within the machine specification of 0.75 mm. Targeting accuracy for isocenters 6-12 cm away from the target is in the range 0.67-1.18 mm. CONCLUSION (A) Single isocenter HyperArc treatments for multiple brain metastases are feasible and targeting accuracy is clinically acceptable. (B) The vertex in a cranial scan is very important for proper alignment.
Collapse
Affiliation(s)
- Fang Li
- Radiation OncologyUPMC Hillman Cancer CenterPittsburghPennsylvaniaUSA
| | - Noor Mail
- Radiation OncologyUPMC Hillman Cancer CenterPittsburghPennsylvaniaUSA
| | | | - Travis J. McCaw
- Radiation OncologyUPMC Hillman Cancer CenterPittsburghPennsylvaniaUSA
| | - Cihat Ozhasoglu
- Radiation OncologyUPMC Hillman Cancer CenterPittsburghPennsylvaniaUSA
| | - Ronald Lalonde
- Radiation OncologyUPMC Hillman Cancer CenterPittsburghPennsylvaniaUSA
| | - Jina Chang
- Radiation OncologyUPMC Hillman Cancer CenterPittsburghPennsylvaniaUSA
| | - Mohammed Saiful Huq
- Radiation OncologyUniversity of Pittsburgh School of Medicine and UPMC Hillman Cancer CenterPittsburghPennsylvaniaUSA
| |
Collapse
|
4
|
Lai JL, Liu SP, Jiang XX, Liu J, Li A, Li B, Li XK, Ye XJ, Lei KJ, Zhou L. Can Optical Surface Imaging Replace Non-coplanar Cone-beam Computed Tomography for Non-coplanar Set-up Verification in Single-isocentre Non-coplanar Stereotactic Radiosurgery and Hypofractionated Stereotactic Radiotherapy for Single and Multiple Brain Metastases? Clin Oncol (R Coll Radiol) 2023; 35:e657-e665. [PMID: 37778972 DOI: 10.1016/j.clon.2023.09.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2023] [Revised: 08/03/2023] [Accepted: 09/18/2023] [Indexed: 10/03/2023]
Abstract
AIMS To conduct a direct comparison regarding the non-coplanar positioning accuracy between the optical surface imaging system Catalyst HDTM and non-coplanar cone-beam computed tomography (NC-CBCT) in intracranial single-isocentre non-coplanar stereotactic radiosurgery (SRS) and hypofractionated stereotactic radiotherapy (HSRT). MATERIALS AND METHODS Twenty patients with between one and five brain metastases who underwent single-isocentre non-coplanar volumetric modulated arc therapy (NC-VMAT) SRS or HSRT were enrolled in this study. For each non-zero couch angle, both Catalyst HDTM and NC-CBCT were used for set-up verification prior to beam delivery. The set-up error reported by Catalyst HDTM was compared with the set-up error derived from NC-CBCT, which was defined as the gold standard. Additionally, the dose delivery accuracy of each non-coplanar field after using Catalyst HDTM and NC-CBCT for set-up correction was measured with SRS MapCHECKTM. RESULTS The median set-up error differences (absolute values) between the two positioning methods were 0.30 mm, 0.40 mm, 0.50 mm, 0.15°, 0.10° and 0.10° in the vertical, longitudinal, lateral, yaw, pitch and roll directions, respectively. The largest absolute set-up error differences regarding translation and rotation were 1.5 mm and 1.1°, which occurred in the longitudinal and yaw directions, respectively. Only 35.71% of the pairs of measurements were within the tolerance of 0.5 mm and 0.5° simultaneously. In addition, the non-coplanar field with NC-CBCT correction yielded a higher gamma passing rate than that with Catalyst HDTM correction (P < 0.05), especially for evaluation criteria of 1%/1 mm with a median increase of 12.8%. CONCLUSIONS Catalyst HDTM may not replace NC-CBCT for non-coplanar set-up corrections in single-isocentre NC-VMAT SRS and HSRT for single and multiple brain metastases. The potential role of Catalyst HDTM in intracranial SRS/HSRT needs to be further studied in the future.
Collapse
Affiliation(s)
- J L Lai
- Radiotherapy Physics & Technology Center, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - S P Liu
- Radiotherapy Physics & Technology Center, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - X X Jiang
- Radiotherapy Physics & Technology Center, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - J Liu
- Department of Oncology, Chengdu First People's Hospital, Chengdu, Sichuan, China
| | - A Li
- Radiotherapy Physics & Technology Center, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - B Li
- Radiotherapy Physics & Technology Center, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - X K Li
- West China Clinical Medical College of Sichuan University, Chengdu, Sichuan, China
| | - X J Ye
- Department of Oncology, Yibin Second People's Hospital, Yibin, Sichuan, China
| | - K J Lei
- Department of Oncology, Yibin Second People's Hospital, Yibin, Sichuan, China
| | - L Zhou
- Thoracic Oncology Ward, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, China.
| |
Collapse
|
5
|
Yamada T, Nakano H, Tanabe S, Sakai T, Tanabe S, Oka T, Sakai H, Oshikane T, Nakano T, Ohta A, Kanazawa T, Kaidu M, Ishikawa H. Verification of Qfix Encompass™ couch modeling using the Acuros XB algorithm and HypeArc™ using a high-spatial-resolution two-dimensional diode array. Med Dosim 2023; 48:261-266. [PMID: 37455221 DOI: 10.1016/j.meddos.2023.06.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2023] [Revised: 05/15/2023] [Accepted: 06/20/2023] [Indexed: 07/18/2023]
Abstract
We modeled the Qfix Encompass™ immobilization system and further verified the calculated dose distribution of the AcurosXB (AXB) dose calculation algorithm using SRS MapCHECKⓇ (SRSMC) in the HyperArc™ (HA) clinical plan. An Encompass system with a StereoPHAN™ QA phantom was scanned by SOMATOM go.Sim and imported to an Eclipse™ treatment planning system to create a treatment plan for Encompass modeling. The Encompass modeling was performed in the StereoPHAN with a pinpoint ion chamber for 6 MV and 6 MV flattening filter free (6 MV FFF), and 2 × 2 cm2, 4 × 4 cm2, and 6 × 6 cm2 irradiation field sizes. The dose calculation algorithm used was AXB ver. 15.5 with a 1.0 mm calculation grid size. The Hounsfield unit (HU) values of the Encompass modeling were set to 400, -100, -200, and -300 for Encompass, and -400, -600, -700, and -800 for the Encompass base. We evaluated the dose distribution after Encompass modeling by SRSMC using gamma analysis in 12 patients. We adopted HU values of -200 for Encompass, -800 for Encompass base for 6 MV, and -200 for Encompass and -700 for Encompass. Base for 6 MV FFF was adopted as the HU values for the Encompass modeling based on the measurement results. The proposed Encompass modeling resulted in a mean pass rate evaluation >98% for both 6 MV and 6 MV FFF when the 1%/1 mm criterion was used, demonstrating that the proposed HU value can be adopted to calculate more accurate dose distributions.
Collapse
Affiliation(s)
- Takumi Yamada
- Section of Radiology, Department of Clinical Support, Niigata University Medical and Dental Hospital, Niigata, 951-8520, Japan
| | - Hisashi Nakano
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, Niigata 951-8520, Japan; Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Osaka, 565-0871, Japan.
| | - Satoshi Tanabe
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, Niigata 951-8520, Japan
| | - Tatsuya Sakai
- Section of Radiology, Department of Clinical Support, Niigata University Medical and Dental Hospital, Niigata, 951-8520, Japan
| | - Shunpei Tanabe
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, Niigata 951-8520, Japan
| | - Tetsuya Oka
- Section of Radiology, Department of Clinical Support, Niigata University Medical and Dental Hospital, Niigata, 951-8520, Japan
| | - Hironori Sakai
- Section of Radiology, Department of Clinical Support, Niigata University Medical and Dental Hospital, Niigata, 951-8520, Japan
| | - Tomoya Oshikane
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, Niigata 951-8520, Japan
| | - Toshimichi Nakano
- Department of Radiology and Radiation Oncology, Niigata University Graduate School of Medical and Dental Sciences, Niigata, 951-8122, Japan
| | - Atsushi Ohta
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, Niigata 951-8520, Japan
| | - Tsutomu Kanazawa
- Section of Radiology, Department of Clinical Support, Niigata University Medical and Dental Hospital, Niigata, 951-8520, Japan
| | - Motoki Kaidu
- Department of Radiology and Radiation Oncology, Niigata University Graduate School of Medical and Dental Sciences, Niigata, 951-8122, Japan
| | - Hiroyuki Ishikawa
- Department of Radiology and Radiation Oncology, Niigata University Graduate School of Medical and Dental Sciences, Niigata, 951-8122, Japan
| |
Collapse
|
6
|
Ikawa T, Kanayama N, Arita H, Ohira S, Takano K, Hirata T, Morimoto M, Teshima T, Konishi K. Linear accelerator-based stereotactic radiotherapy for brain metastases, including multiple and large lesions, carries a low incidence of acute toxicities: a retrospective analysis. Radiat Oncol 2023; 18:80. [PMID: 37165431 PMCID: PMC10173492 DOI: 10.1186/s13014-023-02262-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Accepted: 04/11/2023] [Indexed: 05/12/2023] Open
Abstract
BACKGROUND Data on acute toxicities after stereotactic radiotherapy (SRT) for brain metastases, including multiple and large lesions, are lacking. We aimed to evaluate the incidence and nature of toxicities immediately after SRT using a linear accelerator. METHODS This retrospective study reviewed the medical records of 315 patients with brain metastases treated with SRT at our institution between May 2019 and February 2022. In total, 439 SRT sessions were performed for 2161 brain metastases. The outcome of interest was immediate side effects (ISEs), defined as new or worsening symptoms occurring during SRT or within 14 days after the end of SRT. RESULTS Grade ≥ 2 and ≥ 3 ISEs occurred in 16 (3.6%) and 7 (1.6%) cases, respectively. Among 63 treatments for 10 or more lesions (range: 10-40), 1 (1.6%) ISE occurred. Among 22 treatments for lesions with a maximum tumor volume of > 10 cc, 2 (9.1%) ISEs occurred. Grade ≥ 3 ISEs included 1, 4, 1, and 1 cases of grade 3 nausea, grade 3 new-onset partial and generalized seizures, grade 3 obstructive hydrocephalus, and grade 5 intracranial hemorrhage, respectively. ISEs were more common in patients with a larger maximum tumor volume, primary sites other than lung and breast cancer, and pre-treatment neurological symptoms. CONCLUSION SRT using a linear accelerator for brain metastases, including multiple and large lesions, is safe, with a low incidence of ISEs. Serious complications immediately after SRT are rare but possible; therefore, careful follow-up is necessary after treatment initiation.
Collapse
Affiliation(s)
- Toshiki Ikawa
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan.
| | - Naoyuki Kanayama
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Hideyuki Arita
- Department of Neurosurgery, Osaka International Cancer Institute, Osaka, Japan
| | - Shingo Ohira
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Koji Takano
- Department of Neurosurgery, Osaka International Cancer Institute, Osaka, Japan
| | - Takero Hirata
- Department of Radiation Oncology, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Masahiro Morimoto
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | | | - Koji Konishi
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| |
Collapse
|
7
|
Yamamoto Y, Ohira S, Kanayama N, Inui S, Ueda Y, Koike Y, Miyazaki M, Nishio T, Koizumi M, Konishi K. Comparison of dosimetric parameters and robustness for rotational errors in fractionated stereotactic irradiation using automated noncoplanar volumetric modulated arc therapy for patients with brain metastases: single- versus multi-isocentric technique. Radiol Phys Technol 2023; 16:310-318. [PMID: 37093409 DOI: 10.1007/s12194-023-00720-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Revised: 04/10/2023] [Accepted: 04/11/2023] [Indexed: 04/25/2023]
Abstract
To compare the dosimetric parameters of automated noncoplanar volumetric modulated arc therapy plans using single-isocentric (SIC) and multi-isocentric (MIC) techniques for patients with two brain metastases (BMs) in stereotactic irradiation and to evaluate the robustness of rotational errors. The SIC and MIC plans were retrospectively generated (35 Gy/five fractions) for 58 patients. Subsequently, a receiver operating characteristic curve analysis between the tumor surface distance (TSD) and V25Gy was performed to determine the thresholds for the brain tissue. The SIC and MIC plans were recalculated based on the rotational images to evaluate the dosimetric impact of rotational error. The MIC plans showed better brain tissue sparing for TSD > 6.6 cm. The SIC plans provided a significantly better conformity index for TSD ≤ 6.6 cm, while significantly lower gradient index was obtained (3.22 ± 0.56vs. 3.30 ± 0.57, p < 0.05) in the MIC plans with TSD > 6.6 cm. For organs at risk (OARs) (brainstem, chiasm, lens, optic nerves, and retinas), D0.1 cc was significantly lower (p < 0.05) in the MIC plans than in the SIC plans. The prescription dose could be delivered (D99%) to the gross tumor volume (GTV) for patients with TSD ≤ 6.6 cm when the rotational error was < 1°, whereas 31% of the D99% of GTV fell below the prescription dose with TSD > 6.6 cm. MIC plans can be an optimal approach for reducing doses to OARs and providing robustness against rotational errors in BMs with TSD > 6.6 cm.
Collapse
Affiliation(s)
- Yuki Yamamoto
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan
| | - Shingo Ohira
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Osaka, 537-8567, Japan.
| | - Naoyuki Kanayama
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Osaka, 537-8567, Japan
| | - Shoki Inui
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Osaka, 537-8567, Japan
| | - Yoshihiro Ueda
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Osaka, 537-8567, Japan
| | - Yuhei Koike
- Department of Radiology, Kansai Medical University, Osaka, Japan
| | - Masayoshi Miyazaki
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Osaka, 537-8567, Japan
| | - Teiji Nishio
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan
| | - Masahiko Koizumi
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan
| | - Koji Konishi
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Osaka, 537-8567, Japan
| |
Collapse
|
8
|
Geometric and dosimetric consequences of intra-fractional movement in single isocenter non-coplanar stereotactic radiosurgery. Radiat Oncol 2023; 18:9. [PMID: 36631832 PMCID: PMC9835346 DOI: 10.1186/s13014-022-02195-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2022] [Accepted: 12/29/2022] [Indexed: 01/13/2023] Open
Abstract
PURPOSE To investigate the geometric and dosimetric impacts of intra-fractional movement for patients with single or multiple brain metastasis treated using Varian Hyperarc™ mono-isocentric radiosurgery. METHODS A total of 50 single or hypo-fractionated Hyperarc™ treatment courses (118 lesions) were included in the analysis. Intra-fractional translational and rotational movements were quantified according to the post-treatment cone-beam CT (CBCT). Geometric displacements of all targets were calculated individually based on the assessed head movement in each treatment fraction and their relationships with treatment time and target-to-isocenter distances were studied. For dosimetric analysis, only single-fraction treatments (56 lesions) were included. Re-planning was performed with 0, 1, and 2 mm planning target volume (PTV) margins. Doses were then re-calculated on rotated CT images with isocenter shifted which emulate the change in patient treatment position. Target coverage, target and normal brain doses before and after intra-fractional movement were compared. RESULTS The mean 3D target displacements was 0.6 ± 0.3 (SD) mm. Target shifts for patients treated within 10 min were significantly smaller than those treated in longer sessions. No correlation was found between target shift and target-to-isocenter distance as the origin of head rotation was not located at the isocenter. Loss of target coverage and minimum Gross Tumor Volume (GTV) dose due to intra-fractional movement were apparent only when no margin was used, leading to an extra 23% of the targets violating the dose acceptance criteria, in contrast, the effects on normal brain V12Gy were negligible regardless of the margin used. The use of 1 mm PTV margin can compensate clinically significant geographical miss caused by intra-fractional movements while limiting V12Gy to within dose criteria for 88% of the cases. The plan acceptance rate (fulfillment of both target and normal brain dose criteria) after intra-fractional movement was also the highest with the 1 mm margin. CONCLUSION Although intra-fractional movements during Hyperarc™ treatments were small, there were substantial dosimetric effects due to the sharp dose fall-off near target boundaries. These effects could be mitigated by using a 1 mm PTV margin and maintaining the effective treatment time to within 10 min.
Collapse
|
9
|
Foster RD, Moeller BJ, Robinson M, Bright M, Ruiz JL, Hampton CJ, Heinzerling JH. Dosimetric Analysis of Intra-Fraction Motion Detected by Surface-Guided Radiation Therapy During Linac Stereotactic Radiosurgery. Adv Radiat Oncol 2022; 8:101151. [PMID: 36691448 PMCID: PMC9860342 DOI: 10.1016/j.adro.2022.101151] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2022] [Accepted: 12/14/2022] [Indexed: 12/28/2022] Open
Abstract
Purpose Stereotactic radiosurgery (SRS) immobilization with an open face mask is more comfortable and less invasive than frame based, but concerns about intrafraction motion must be addressed. Surface-guided radiation therapy (SGRT) is an attractive option for intrafraction patient monitoring because it is continuous, has submillimeter accuracy, and uses no ionizing radiation. The purpose of this study was to investigate the dosimetric consequences of uncorrected intrafraction patient motion detected during frameless linac-based SRS. Methods and Materials Fifty-five SRS patients were monitored during treatment using SGRT between January 1, 2017, and September 30, 2020. If SGRT detected motion >1 mm, imaging was repeated and the necessary shifts were made before continuing treatment. For the 25 patients with intrafraction 3-dimensional vector shifts of ≥1 mm, we moved the isocenter in the planning system using the translational shifts from the repeat imaging and recalculated the plans to determine the dosimetric effect of the shifts. Planning target volume (PTV) coverage, minimum gross tumor volume (GTV) dose (relative and absolute), and normal brain V12 were evaluated. Wilcoxon signed rank tests were used to compare planned and simulated dosimetric parameters and median 2 sample tests were used to investigate these differences between cone and multileaf collimator (MLC) plans. Results For simulated plans, V12 increased by a median of 0.01 cc (P = .006) and relative GTV minimum dose and PTV coverage decreased by a median of 15.8% (P < .001) and 10.2 % (P < .001), respectively. Absolute minimum GTV dose was found to be significantly lower in the simulated plans (P < .001). PTV coverage decreased more for simulated cone plans than for simulated MLC plans (11.6% vs 4.7%, P = .011) but median V12 differences were found to be significantly larger for MLC plans (-0.34 cc vs -0.01 cc, P = .011). Differences in GTV minimum dose between cone and MLC plans were not statistically significant. Conclusions SGRT detected clinically meaningful intrafraction motion during frameless SRS, which could lead to large underdoses and increased normal brain dose if uncorrected.
Collapse
Affiliation(s)
- Ryan D. Foster
- Levine Cancer Institute, Atrium Health, Concord, North Carolina,Corresponding author: Ryan Foster, PhD
| | - Benjamin J. Moeller
- Levine Cancer Institute, Atrium Health and Southeast Radiation Oncology Group, Charlotte, North Carolina
| | - Myra Robinson
- Levine Cancer Institute, Atrium Health, Charlotte, North Carolina
| | - Megan Bright
- Levine Cancer Institute, Atrium Health, Concord, North Carolina
| | - Justin L. Ruiz
- Levine Cancer Institute, Atrium Health, Concord, North Carolina
| | | | - John H. Heinzerling
- Levine Cancer Institute, Atrium Health and Southeast Radiation Oncology Group, Charlotte, North Carolina
| |
Collapse
|
10
|
Machine learning-based treatment couch parameter prediction in support of surface guided radiation therapy. Tech Innov Patient Support Radiat Oncol 2022; 23:15-20. [PMID: 36039333 PMCID: PMC9418545 DOI: 10.1016/j.tipsro.2022.08.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Revised: 08/02/2022] [Accepted: 08/09/2022] [Indexed: 11/30/2022] Open
Abstract
Optimizing surface guided radiation therapy workflow. Machine learning-based automatic treatment couch parameters prediction. quality assurance for patient positioning.
Purpose A fully independent, machine learning-based automatic treatment couch parameters prediction was developed to support surface guided radiation therapy (SGRT)-based patient positioning protocols. Additionally, this approach also acts as a quality assurance tool for patient positioning. Materials/Methods Setup data of 183 patients, divided into four different groups based on used setup devices, was used to calculate the difference between the predicted and the acquired treatment couch value. Results Couch parameters can be predicted with high precision μ=0.90,σ=0.92. A significant difference (p < 0.01) between the variances of Lung and Brain patients was found. Outliers were not related to the prediction accuracy, but are due to inconsistencies during initial patient setup. Conclusion Couch parameters can be predicted with high accuracy and can be used as starting point for SGRT-based patient positioning. In case of large deviations (>1.5 cm), patient setup has to be verified to optimally use the surface scanning system.
Collapse
|
11
|
Kanayama N, Ikawa T, Ohira S, Hirata T, Morimoto M, Ogawa K, Teshima T, Konishi K. Volumetric reduction of brain metastases after stereotactic radiotherapy: Prognostic factors and effect on local control. Cancer Med 2022; 11:4806-4815. [PMID: 35535485 PMCID: PMC9761087 DOI: 10.1002/cam4.4809] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2022] [Revised: 04/11/2022] [Accepted: 04/25/2022] [Indexed: 02/03/2023] Open
Abstract
BACKGROUND AND PURPOSE Few reports include volumetric measurements as endpoints after stereotactic radiotherapy (SRT) despite the importance of such measurements. This study aimed to (1) investigate the impact of the volumetric response (specifically, an over 65% and over 90% volume reduction in brain metastases) at 6 months post-SRT on local control and (2) identify the predictive factors for a volumetric response of over 65% and over 90%. MATERIALS AND METHODS This study included 250 unresected brain metastases (>0.3 cc) treated with SRT. Doses were stratified according to the biological effective dose (BED). The BED was calculated using four models: linear-quadratic (LQ): α/β = 10; LQ: α/β = 20; LQ cubic: α/β = 12; and LQ linear: α/β = 10. The median prescription dose was 30 Gy/3 fractions (BED20, 45). The median follow-up time after SRT was 18.6 months (range, 6.4-81.8 months). RESULTS In the multivariate analysis, over 65% volume reduction and over 90% volume reduction were prognostic factors for local control (hazard ratio: 2.370, p = 0.011 and hazard ratio: 3.161, p = 0.014, respectively). A dose of 80% of the gross tumor volume (GTV) D80 > BED20 58 was a predictive factor for over 65% and over 90% volume reductions (odds ratio: 1.975, p = 0.023; odds ratio: 3.204, p < 0.001, respectively). CONCLUSION Robust volume reduction of brain metastases at 6 months post-SRT can predict local control. GTV D80 in the LQ model: α/β = 20 may be warranted for good volume reduction.
Collapse
Affiliation(s)
- Naoyuki Kanayama
- Department of Radiation Oncology, Osaka International Center InstituteOsakaJapan
| | - Toshiki Ikawa
- Department of Radiation Oncology, Osaka International Center InstituteOsakaJapan
| | - Shingo Ohira
- Department of Radiation Oncology, Osaka International Center InstituteOsakaJapan
| | - Takero Hirata
- Department of Radiation OncologyOsaka University Graduate School of MedicineOsakaJapan
| | - Masahiro Morimoto
- Department of Radiation Oncology, Osaka International Center InstituteOsakaJapan
| | - Kazuhiko Ogawa
- Department of Radiation OncologyOsaka University Graduate School of MedicineOsakaJapan
| | | | - Koji Konishi
- Department of Radiation Oncology, Osaka International Center InstituteOsakaJapan
| |
Collapse
|
12
|
Han C, Amini A, Wong JYC, Liang J, Qing K, Watkins WT, Zhang S, Williams TM, Liu A. Comparison of intrafractional motion with two frameless immobilization systems in surface-guided intracranial stereotactic radiosurgery. J Appl Clin Med Phys 2022; 23:e13613. [PMID: 35441441 PMCID: PMC9195026 DOI: 10.1002/acm2.13613] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Revised: 03/12/2022] [Accepted: 04/21/2022] [Indexed: 11/28/2022] Open
Abstract
Purpose/objectives The aim of this study is to compare intrafractional motion using two commercial non‐invasive immobilization systems for linac‐based intracranial stereotactic radiosurgery (SRS) under guidance with a surface‐guided radiotherapy (SGRT) system. Materials/methods Twenty‐one patients who received intracranial SRS were retrospectively selected. Ten patients were immobilized with a vacuum fixation biteplate system, while 11 patients were immobilized with an open‐face mask system. A setup margin of 1 mm was used in treatment planning. Real‐time surface motion data in 37 treatment fractions using the vacuum fixation system and 44 fractions using the open‐face mask were recorded by an SGRT system. Variances of intrafractional motion along three translational directions and three rotational directions were compared between the two immobilization techniques with Levene's tests. Intrafractional motion variation over time during treatments was also evaluated. Results Using the vacuum fixation system, the average and standard deviations of the shifts were 0.01 ± 0.18 mm, ‐0.06 ± 0.30 mm, and 0.02 ± 0.26 mm in the anterior–posterior (AP), superior–inferior (SI), and left–right (LR) directions, and ‐0.02 ± 0.19°, ‐0.01 ± 0.13°, and 0.01 ± 0.13° for rotations in yaw, roll, and pitch, respectively; using the open‐face mask system, the average and standard deviations of the shifts were ‐0.06 ± 0.20 mm, ‐0.02 ± 0.35 mm, and 0.01 ± 0.40 mm in the AP, SI, and LR directions, and were 0.05 ± 0.23°, 0.02 ± 0.21°, and 0.00 ± 0.16° for rotations in yaw, roll, and pitch, respectively. There was a significant increase in intrafractional motion variance over time during treatments. Conclusion Patients with the vacuum fixation system had significantly smaller intrafractional motion variation compared to those with the open‐face mask system. Using intrafractional motion techniques such as surface imaging system is recommended to minimize dose deviation due to intrafractional motion. The increase in intrafractional motion over time indicates clinical benefits with shorter treatment time.
Collapse
Affiliation(s)
- Chunhui Han
- Department of Radiation Oncology, City of Hope National Medical Center, Duarte, California, USA
| | - Arya Amini
- Department of Radiation Oncology, City of Hope National Medical Center, Duarte, California, USA
| | - Jeffrey Y C Wong
- Department of Radiation Oncology, City of Hope National Medical Center, Duarte, California, USA
| | - Jieming Liang
- Department of Radiation Oncology, City of Hope National Medical Center, Duarte, California, USA
| | - Kun Qing
- Department of Radiation Oncology, City of Hope National Medical Center, Duarte, California, USA
| | - W Tyler Watkins
- Department of Radiation Oncology, City of Hope National Medical Center, Duarte, California, USA
| | - Sean Zhang
- Department of Radiation Oncology, City of Hope National Medical Center, Duarte, California, USA
| | - Terence M Williams
- Department of Radiation Oncology, City of Hope National Medical Center, Duarte, California, USA
| | - An Liu
- Department of Radiation Oncology, City of Hope National Medical Center, Duarte, California, USA
| |
Collapse
|
13
|
Ohira S, Komiyama R, Kanayama N, Ueda Y, Inui S, Miyazaki M, Koizumi M, Konishi K. Intra‐fractional motion error during HyperArc stereotactic radiosurgery on patients with brain metastases: Comparison of open and full‐face clamshell‐style immobilization devices. J Appl Clin Med Phys 2022; 23:e13536. [PMID: 35049125 PMCID: PMC8992945 DOI: 10.1002/acm2.13536] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2021] [Revised: 11/14/2021] [Accepted: 01/06/2022] [Indexed: 11/23/2022] Open
Abstract
Purpose To compare the intrafractional motion error (IME) during stereotactic irradiation (STI) in patients with brain metastases immobilized using open‐ (Encompass) and full‐face (DSPS) clamshell‐style immobilization devices. Methods Encompass (38 patients) and DSPS (38 patients) were used for patient immobilization, and HyperArc plans with three to four non‐coplanar beams were generated to deliver 25 to 35 Gy in three to five fractions. Cone‐beam computed tomography (CBCT) was performed on patients before and after the treatment. Moreover, the difference in patient position between the two CBCT images was considered as the IME. The margins to compensate for IME were calculated using the van Herk margin formula. Results For Encompass, the mean values of IME in the translational setup were 0.1, 0.2, and 0.0 mm in the anterior–posterior, superior–inferior, and left–right directions, respectively, and the mean values of IME about rotational axes were −0.1, 0.0, and 0.0° for the Pitch, Roll, and Yaw rotations, respectively. For DSPS, the mean values of IME in the translational setup were 0.2, 0.2, and 0.0 mm in the anterior–posterior, superior–inferior, and left–right directions, respectively, and the mean values of IME about rotational axes were −0.1, −0.1, and 0.0° for the Pitch, Roll, and Yaw rotations, respectively. No statistically significant difference was observed between the IME of the two immobilization systems except in the anterior–posterior direction (p = 0.02). Moreover, no statistically significant correlation was observed between three‐dimensional IME and treatment time. The margin compensation for IME was less than 1 mm for both immobilization devices. Conclusions The IME during STI using open‐ and full‐face clamshell‐style immobilization devices is approximately equal considering the adequate accuracy in patient positioning.
Collapse
Affiliation(s)
- Shingo Ohira
- Department of Radiation Oncology Osaka International Cancer Institute Osaka Japan
- Department of Medical Physics and Engineering Osaka University Graduate School of Medicine Suita Japan
| | - Riho Komiyama
- Department of Radiation Oncology Osaka International Cancer Institute Osaka Japan
| | - Naoyuki Kanayama
- Department of Radiation Oncology Osaka International Cancer Institute Osaka Japan
| | - Yoshihiro Ueda
- Department of Radiation Oncology Osaka International Cancer Institute Osaka Japan
| | - Shoki Inui
- Department of Radiation Oncology Osaka International Cancer Institute Osaka Japan
| | - Masayoshi Miyazaki
- Department of Radiation Oncology Osaka International Cancer Institute Osaka Japan
| | - Masahiko Koizumi
- Department of Medical Physics and Engineering Osaka University Graduate School of Medicine Suita Japan
| | - Koji Konishi
- Department of Radiation Oncology Osaka International Cancer Institute Osaka Japan
| |
Collapse
|