Wu K, Zhu X, Bifano TG, Anderson SW, Zhang X. Computational-Design Enabled Wearable and Tunable Metamaterials via Freeform Auxetics for Magnetic Resonance Imaging. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024:e2400261. [PMID: 38659228 DOI: 10.1002/advs.202400261] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/22/2024] [Indexed: 04/26/2024]
Abstract
Metamaterials hold significant promise for enhancing the imaging capabilities of magnetic resonance imaging (MRI) machines as an additive technology, due to their unique ability to enhance local magnetic fields. However, despite their potential, the metamaterials reported in the context of MRI applications have often been impractical. This impracticality arises from their predominantly flat configurations and their susceptibility to shifts in resonance frequencies, preventing them from realizing their optimal performance. Here, a computational method for designing wearable and tunable metamaterials via freeform auxetics is introduced. The proposed computational-design tools yield an approach to solving the complex circle packing problems in an interactive and efficient manner, thus facilitating the development of deployable metamaterials configured in freeform shapes. With such tools, the developed metamaterials may readily conform to a patient's knee, ankle, head, or any part of the body in need of imaging, and while ensuring an optimal resonance frequency, thereby paving the way for the widespread adoption of metamaterials in clinical MRI applications.
Collapse
Affiliation(s)
- Ke Wu
- Department of Mechanical Engineering, Boston University, Boston, MA, 02215, USA
- Photonics Center, Boston University, Boston, MA, 02215, USA
| | - Xia Zhu
- Department of Mechanical Engineering, Boston University, Boston, MA, 02215, USA
- Photonics Center, Boston University, Boston, MA, 02215, USA
| | | | - Stephan W Anderson
- Photonics Center, Boston University, Boston, MA, 02215, USA
- Boston University Chobanian and Avedisian School of Medicine, Boston, MA, 02118, USA
| | - Xin Zhang
- Department of Mechanical Engineering, Boston University, Boston, MA, 02215, USA
- Photonics Center, Boston University, Boston, MA, 02215, USA
| |
Collapse
|
2
|
Zhu X, Wu K, Anderson SW, Zhang X. Wearable Coaxially-Shielded Metamaterial for Magnetic Resonance Imaging. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024:e2313692. [PMID: 38569592 DOI: 10.1002/adma.202313692] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Revised: 03/04/2024] [Indexed: 04/05/2024]
Abstract
Recent advancements in metamaterials have yielded the possibility of a wireless solution to improve signal-to-noise ratio (SNR) in magnetic resonance imaging (MRI). Unlike traditional closely packed local coil arrays with rigid designs and numerous components, these lightweight, cost-effective metamaterials eliminate the need for radio frequency cabling, baluns, adapters, and interfaces. However, their clinical adoption is limited by their low sensitivity, bulky physical footprint, and limited, specific use cases. Herein, a wearable metamaterial developed using commercially available coaxial cable, designed for a 3.0 T MRI system is introduced. This metamaterial inherits the coaxially-shielded structure of its constituent cable, confining the electric field within and mitigating coupling to its surroundings. This ensures safer clinical adoption, lower signal loss, and resistance to frequency shifts. Weighing only 50 g, the metamaterial maximizes its sensitivity by conforming to the anatomical region of interest. MRI images acquired using this metamaterial with various pulse sequences achieve an SNR comparable or even surpass that of a state-of-the-art 16-channel knee coil. This work introduces a novel paradigm for constructing metamaterials in the MRI environment, paving the way for the development of next-generation wireless MRI technology.
Collapse
Affiliation(s)
- Xia Zhu
- Department of Mechanical Engineering, Boston University, Boston, MA, 02215, USA
- Photonics Center, Boston University, Boston, MA, 02215, USA
| | - Ke Wu
- Department of Mechanical Engineering, Boston University, Boston, MA, 02215, USA
- Photonics Center, Boston University, Boston, MA, 02215, USA
| | - Stephan W Anderson
- Photonics Center, Boston University, Boston, MA, 02215, USA
- Department of Radiology, Boston University Chobanian & Avedisian School of Medicine, Boston, MA, 02118, USA
| | - Xin Zhang
- Department of Mechanical Engineering, Boston University, Boston, MA, 02215, USA
- Photonics Center, Boston University, Boston, MA, 02215, USA
| |
Collapse
|
3
|
Maurya SK, Schmidt R. A Metamaterial-like Structure Design Using Non-uniformly Distributed Dielectric and Conducting Strips to Boost the RF Field Distribution in 7 T MRI. SENSORS (BASEL, SWITZERLAND) 2024; 24:2250. [PMID: 38610461 PMCID: PMC11014008 DOI: 10.3390/s24072250] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/22/2024] [Revised: 03/24/2024] [Accepted: 03/28/2024] [Indexed: 04/14/2024]
Abstract
Metamaterial-based designs in ultra-high field (≥7 T) MRI have the promise of increasing the local magnetic resonance imaging (MRI) signal and potentially even the global efficiency of both the radiofrequency (RF) transmit and receive resonators. A recently proposed metamaterial-like structure-comprised of a high-permittivity dielectric material and a set of evenly distributed copper strips-indeed resulted in a local increase in RF transmission. Here, we demonstrate that non-uniform designs of this metamaterial-like structure can be used to boost the ultimate RF field distribution. A non-uniform dielectric distribution can yield longer electric dipoles, thus extending the RF transmit field coverage. A non-uniform distribution of conducting strips enables the tailoring of the local electric field hot spots, where a concave distribution resulted in lower power deposition. Simulations of the brain and calf regions using our new metamaterial-like design, which combines non-uniform distributions of both the dielectric and conducting strips, revealed a 1.4-fold increase in the RF field coverage compared to the uniform distribution, and a 1.5-2-fold increase in the transmit efficiency compared to the standard surface-coil.
Collapse
Affiliation(s)
- Santosh Kumar Maurya
- Department of Brain Sciences, Weizmann Institute of Science, Rehovot 7610001, Israel;
- The Azrieli National Institute for Human Brain Imaging and Research, Weizmann Institute of Science, Rehovot 7610001, Israel
| | - Rita Schmidt
- Department of Brain Sciences, Weizmann Institute of Science, Rehovot 7610001, Israel;
- The Azrieli National Institute for Human Brain Imaging and Research, Weizmann Institute of Science, Rehovot 7610001, Israel
| |
Collapse
|
4
|
Jacobs PS, Wilson N, Brink W, Swain A, Armbruster R, Hanumapur A, Tisdall MD, Detre J, Nanga RPR, Elliott MA, Reddy R. In vivo B 1 + enhancement of calf MRI at 7 T via optimized flexible metasurfaces. Magn Reson Med 2024. [PMID: 38469893 DOI: 10.1002/mrm.30060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Revised: 01/18/2024] [Accepted: 02/05/2024] [Indexed: 03/13/2024]
Abstract
PURPOSE Ultrahigh field (≥7 T) MRI is at the cutting edge of medical imaging, enabling enhanced spatial and spectral resolution as well as enhanced susceptibility contrast. However, transmit (B 1 + $$ {\mathrm{B}}_1^{+} $$ ) field inhomogeneity due to standing wave effects caused by the shortened RF wavelengths at 7 T is still a challenge to overcome. Novel hardware methods such as dielectric pads have been shown to improve theB 1 + $$ {\mathrm{B}}_1^{+} $$ field inhomogeneity but are currently limited in their corrective effect by the range of high-permittivity materials available and have a fixed shelf life. In this work, an optimized metasurface design is presented that demonstrates in vivo enhancement of theB 1 + $$ {\mathrm{B}}_1^{+} $$ field. METHODS A prototype metasurface was optimized by an empirical capacitor sweep and by varying the period size. Phantom temperature experiments were performed to evaluate potential metasurface heating effects during scanning. Lastly, in vivo gradient echo images andB 1 + $$ {\mathrm{B}}_1^{+} $$ maps were acquired on five healthy subjects on a 7 T system. Dielectric pads were also used as a comparison throughout the work as a standard comparison. RESULTS The metasurfaces presented here enhanced the average relative SNR of the gradient echo images by a factor of 2.26 compared to the dielectric pads factor of 1.61. AverageB 1 + $$ {\mathrm{B}}_1^{+} $$ values reflected a similar enhancement of 27.6% with the metasurfaces present versus 8.9% with the dielectric pads. CONCLUSION The results demonstrate that metasurfaces provide superior performance to dielectric padding as shown byB 1 + $$ {\mathrm{B}}_1^{+} $$ maps reflecting their direct effects and resulting enhancements in image SNR at 7 T.
Collapse
Affiliation(s)
- Paul S Jacobs
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Neil Wilson
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Wyger Brink
- Magnetic Detection and Imaging group, TechMed Centre, University of Twente, Enschede, The Netherlands
| | - Anshuman Swain
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Ryan Armbruster
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Aniketh Hanumapur
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - M Dylan Tisdall
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - John Detre
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
- Department of Neurology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Ravi Prakash Reddy Nanga
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Mark A Elliott
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Ravinder Reddy
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| |
Collapse
|
5
|
Ren Q, Lang Y, Jia Y, Xiao X, Liu Y, Kong X, Jin R, He Y, Zhang J, You JW, Sha WEI, Pang Y. High-Q metasurface signal isolator for 1.5T surface coil magnetic resonance imaging on the go. OPTICS EXPRESS 2024; 32:8751-8762. [PMID: 38571125 DOI: 10.1364/oe.514806] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Accepted: 01/24/2024] [Indexed: 04/05/2024]
Abstract
The combination of surface coils and metamaterials remarkably enhance magnetic resonance imaging (MRI) performance for significant local staging flexibility. However, due to the coupling in between, impeded signal-to-noise ratio (SNR) and low-contrast resolution, further hamper the future growth in clinical MRI. In this paper, we propose a high-Q metasurface decoupling isolator fueled by topological LC loops for 1.5T surface coil MRI system, increasing the magnetic field up to fivefold at 63.8 MHz. We have employed a polarization conversion mechanism to effectively eliminate the coupling between the MRI metamaterial and the radio frequency (RF) surface transmitter-receiver coils. Furthermore, a high-Q metasurface isolator was achieved by taking advantage of bound states in the continuum (BIC) for extremely high-resolution MRI and spectroscopy. An equivalent physical model of the miniaturized metasurface design was put forward through LC circuit analysis. This study opens up a promising route for the easy-to-use and portable surface coil MRI scanners.
Collapse
|
6
|
Zhu H, Lang ML, Yang Y, Martin M, Zhang G, Zhang Q, Chen Y, Yan X. Detunable wireless Litzcage coil for human head MRI at 1.5 T. NMR IN BIOMEDICINE 2024; 37:e5068. [PMID: 37964107 DOI: 10.1002/nbm.5068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Revised: 10/09/2023] [Accepted: 10/11/2023] [Indexed: 11/16/2023]
Abstract
Inductively coupled radiofrequency (RF) coils are an inexpensive and simple method to realize wireless RF coils in magnetic resonance imaging (MRI), which can significantly ease the MRI scan setup and improve patient comfort because they do not require bulky components such as cables, baluns, preamplifiers, and connectors. However, volume-type wireless coils are typically operated in transmit/receive mode because detuning such coils is much more challenging due to their complex structure and multiple resonant modes. Meanwhile, adding too many detuning circuits to a wireless coil would decrease the coil's quality factor, impair the signal-to-noise ratio, and increase the cost. In this work, we proposed, constructed, and tested a novel wireless volume coil based on the Litzcage design for 1.5-T head imaging. Being an inductively coupled coil, it has a much simpler structure, resulting in a lighter weight and less bulky design. Despite its simpler structure, it exhibits comparable imaging performance with a commercial receive array, providing an alternative to conventional wired coils with a high cost and complex structure. The unique figure-of-8 conductor pattern within the rungs ensures that the proposed wireless Litzcage can be efficiently detuned with minimal detuning circuits.
Collapse
Affiliation(s)
- Haoqin Zhu
- Sino Canada Health Institute Inc., Winnipeg, Manitoba, Canada
| | - Michael L Lang
- Sino Canada Health Institute Inc., Winnipeg, Manitoba, Canada
- Department of Physics, The University of Winnipeg, Winnipeg, Manitoba, Canada
| | - Yijin Yang
- Department of Electrical and Computer Engineering, Vanderbilt University, Nashville, Tennessee, USA
| | - Melanie Martin
- Department of Physics, The University of Winnipeg, Winnipeg, Manitoba, Canada
| | - Gong Zhang
- Hubei Key Laboratory of Intelligent Conveying Technology and Device, Hubei Polytechnic University, Huangshi, China
| | - Qiang Zhang
- The Affiliated Hospital of Inner Mongolia Medical University, Hohhot, China
| | - Yuanyuan Chen
- Sino Canada Health Engineering Research Institute (Hefei) Ltd., Hefei, Anhui, China
| | - Xinqiang Yan
- Department of Electrical and Computer Engineering, Vanderbilt University, Nashville, Tennessee, USA
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, Tennessee, USA
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| |
Collapse
|
7
|
Jandaliyeva A, Puchnin V, Shchelokova A. Volumetric wireless coils for breast MRI: A comparative analysis of metamaterial-inspired coil, Helmholtz coil, ceramic coil, and solenoid. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2024; 359:107627. [PMID: 38280267 DOI: 10.1016/j.jmr.2024.107627] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 01/18/2024] [Accepted: 01/18/2024] [Indexed: 01/29/2024]
Abstract
This study comprehensively assesses radiofrequency (RF) volumetric wireless coils utilizing artificial materials for clinical breast MRI. In particular, we evaluated the transmit efficiency, RF safety, and homogeneity of magnetic field amplitude distribution for four structures electromagnetically coupled with a whole-body birdcage coil: extremely high permittivity ceramic coil, solenoid coil, Helmholtz coil, and metamaterial-inspired coil based on periodically coupled split-loop resonators. These coils exhibit favorable attributes, including lightweight construction, compactness, cost-effectiveness, and ease of manufacturing. The results of this study demonstrated that the metamaterial-inspired coil outperforms other wireless coils considered for addressing a specific problem in terms of the set of characteristics. In particular, the metamaterial-inspired coil achieved 85% and 88% homogeneity in magnetic field amplitude distribution at 3 T and 1.5 T MRI, respectively. Also, the 1.5 T metamaterial-inspired coil demonstrated the best performance, increasing the efficiency gain of the birdcage coil by 4.93 times and improving RF safety by 2.96 times. This research explains the limitations and peculiarity of utilizing the volumetric wireless coils in 1.5 and 3 T MRI systems.
Collapse
Affiliation(s)
| | - Viktor Puchnin
- School of Physics and Engineering, ITMO University, St. Petersburg, Russia.
| | - Alena Shchelokova
- School of Physics and Engineering, ITMO University, St. Petersburg, Russia
| |
Collapse
|
8
|
Yi Y, Chi Z, Wang Y, Wu M, Wang L, Jiang D, He L, Qi Y, Li X, Zhao X, Meng Y, Zhou J, Zhao Q, Zheng Z. In vivo MRI of knee using a metasurface-inspired wireless coil. Magn Reson Med 2024; 91:530-540. [PMID: 37814581 DOI: 10.1002/mrm.29870] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 08/26/2023] [Accepted: 08/30/2023] [Indexed: 10/11/2023]
Abstract
PURPOSE To investigate the application of a metasurface-inspired wireless coil and evaluate its performance in clinical knee MRI. METHODS A metasurface surface coil is designed for knee MRI at 1.5T. The image SNR and uniformity are assessed using a water phantom. In vivo studies are performed on 10 healthy volunteers (age range, 24-30 y; three males) and two patients (ages 31 and 76 y; two males) with knee conditions. A commercial 4-channel flexible coil and a 12-channel knee coil are used for comparison. The SNRs of different tissues on knee MRI images are evaluated and compared. The image quality is evaluated using a five-point Likert scale. RESULTS The SNRs of the images acquired by the metasurface coil with spine coil as receiving coil are similar to the 12-channel knee coil, whereas the uniformity from groups where the metasurface coil was used is higher than that acquired by conventional coils in phantom studies. For in vivo knee MRI, the SNRs of the images acquired by the metasurface coil with spine coil as receiving coil are between that of the 4- and 12-channel phased-array coils. The image quality scores evaluated by radiologists are higher when metasurface is used. CONCLUSION The metasurface-inspired wireless coil is applicable to clinical knee MRI. When used in conjunction with the spine coil, it provides a favorable SNR between that of the 4- and 12-channel phased-array coil at 1.5T MRI system. The metasurface coil improves image uniformity regardless of which coil is used as the receiving coil.
Collapse
Affiliation(s)
- Yi Yi
- Department of Radiology, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, Beijing, China
| | - Zhonghai Chi
- State Key Laboratory of Tribology, Department of Mechanical Engineering, Tsinghua University, Beijing, China
| | - Yakui Wang
- Department of Radiology, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, Beijing, China
| | - Maopeng Wu
- State Key Laboratory of Tribology, Department of Mechanical Engineering, Tsinghua University, Beijing, China
| | - Lixue Wang
- Department of Radiology, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, Beijing, China
| | - Deqing Jiang
- Department of Radiology, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, Beijing, China
| | - Li He
- Department of Radiology, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, Beijing, China
| | - Yingyi Qi
- State Key Laboratory of Tribology, Department of Mechanical Engineering, Tsinghua University, Beijing, China
| | - Xinxin Li
- State Key Laboratory of Tribology, Department of Mechanical Engineering, Tsinghua University, Beijing, China
| | - Xihai Zhao
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| | - Yonggang Meng
- State Key Laboratory of Tribology, Department of Mechanical Engineering, Tsinghua University, Beijing, China
| | - Ji Zhou
- State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing, China
| | - Qian Zhao
- State Key Laboratory of Tribology, Department of Mechanical Engineering, Tsinghua University, Beijing, China
| | - Zhuozhao Zheng
- Department of Radiology, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, Beijing, China
| |
Collapse
|
9
|
Das P, Gupta J, Sikdar D, Bhattacharjee R. Aperture-patch sandwich metasurface for magnetic field enhancement in 1.5 T MRI. Magn Reson Imaging 2023; 100:1-9. [PMID: 36924809 DOI: 10.1016/j.mri.2023.03.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 03/05/2023] [Accepted: 03/12/2023] [Indexed: 03/17/2023]
Abstract
Magnetic resonance imaging (MRI) is an increasingly popular non-invasive technique for clinical diagnosis. Signal-to-noise ratio (SNR) is a crucial performance metric of MRI, improvement of which can be exchanged for increased image resolution or decreased scan time. Besides the progress in various hardware and software techniques for improving SNR in MRI scanners, use of metasurfaces as accessories has recently shown potential towards enhancing SNR by boosting local magnetic field in the scanned volume. Magnetic field enhancement over a larger depth from the skin is essential for imaging of deeper tissues, which can be facilitated by a specifically designed metasurface. Here we present such a metasurface with complementary-type resonant structures on the two sides of a high-permittivity dielectric, which substantially increases magnetic flux density on the skin (forty-five fold) that decays down to unity at a depth of 95 mm from the skin. This results in boosting of SNR up to forty-fold on the skin in 1.5 T MRI, while keeping tissue heating below the safety limit. An original analytical approach is formulated to readily estimate the SNR enhancement factor of this metasurface. Using the designed metasurface as an accessory for MRI scanners could help making MRI scans more efficient and affordable.
Collapse
Affiliation(s)
- Priyanka Das
- iHUB DivyaSampark, Indian Institute of Technology Roorkee, Roorkee, Uttarakhand 247667, India.
| | - Jegyasu Gupta
- Department of Electronics and Electrical Engineering, Indian Institute of Technology Guwahati, Guwahati, Assam 781039, India
| | - Debabrata Sikdar
- Department of Electronics and Electrical Engineering, Indian Institute of Technology Guwahati, Guwahati, Assam 781039, India
| | - Ratnajit Bhattacharjee
- Department of Electronics and Electrical Engineering, Indian Institute of Technology Guwahati, Guwahati, Assam 781039, India
| |
Collapse
|
10
|
Sun P, Wu Z, Lin L, Hu G, Zhang X, Wang J. MR-Nucleomics: The study of pathological cellular processes with multinuclear magnetic resonance spectroscopy and imaging in vivo. NMR IN BIOMEDICINE 2023; 36:e4845. [PMID: 36259659 DOI: 10.1002/nbm.4845] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Revised: 09/28/2022] [Accepted: 10/08/2022] [Indexed: 06/16/2023]
Abstract
Clinical medicine has experienced a rapid development in recent decades, during which therapies targeting specific cellular signaling pathways, or specific cell surface receptors, have been increasingly adopted. While these developments in clinical medicine call for improved precision in diagnosis and treatment monitoring, modern medical imaging methods are restricted mainly to anatomical imaging, lagging behind the requirements of precision medicine. Although positron emission tomography and single photon emission computed tomography have been used clinically for studies of metabolism, their applications have been limited by the exposure risk to ionizing radiation, the subsequent limitation in repeated and longitudinal studies, and the incapability in assessing downstream metabolism. Magnetic resonance spectroscopy (MRS) or spectroscopic imaging (MRSI) are, in theory, capable of assessing molecular activities in vivo, although they are often limited by sensitivity. Here, we review some recent developments in MRS and MRSI of multiple nuclei that have potential as molecular imaging tools in the clinic.
Collapse
Affiliation(s)
- Peng Sun
- Clinical & Technical Support, Philips Healthcare, China
| | - Zhigang Wu
- Clinical & Technical Support, Philips Healthcare, China
| | - Liangjie Lin
- Clinical & Technical Support, Philips Healthcare, China
| | - Geli Hu
- Clinical & Technical Support, Philips Healthcare, China
| | | | - Jiazheng Wang
- Clinical & Technical Support, Philips Healthcare, China
| |
Collapse
|
11
|
Simulation Study of Radio Frequency Safety and the Optimal Size of a Single-Channel Surface Radio Frequency Coil for Mice at 9.4 T Magnetic Resonance Imaging. SENSORS 2022; 22:s22114274. [PMID: 35684895 PMCID: PMC9185248 DOI: 10.3390/s22114274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/22/2022] [Revised: 05/22/2022] [Accepted: 06/01/2022] [Indexed: 12/04/2022]
Abstract
The optimized size of a single-channel surface radio frequency (RF) coil for mouse body images in a 9.4 T magnetic resonance imaging (MRI) system was determined via electromagnetic-field analysis of the signal depth according to the size of a single-channel coil. The single-channel surface RF coils used in electromagnetic field simulations were configured to operate in transmission/reception mode at a frequency of 9.4 T–400 MHz. Computational analysis using the finite-difference time-domain method was used to assess the single-channel surface RF coil by comparing single-channel surface RF coils of varying sizes in terms of |B1|-, |B1+|-, |B1−|- and |E|-field distribution. RF safety for the prevention of burn injuries to small animals was assessed using an analysis of the specific absorption rate. A single-channel surface RF coil with a 20 mm diameter provided optimal B1-field distribution and RF safety, thus confirming that single-channel surface RF coils with ≥25 mm diameter could not provide typical B1-field distribution. A single-channel surface RF coil with a 20 mm diameter for mouse body imaging at 9.4 T MRI was recommended to preserve the characteristics of single-channel surface RF coils, and ensured that RF signals were applied correctly to the target point within RF safety guidelines.
Collapse
|
12
|
Brui E, Mikhailovskaya A, Solomakha G, Efimtcev A, Andreychenko A, Shchelokova A. Volumetric wireless coil for wrist MRI at 1.5 T as a practical alternative to Tx/Rx extremity coil: a comparative study. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2022; 339:107209. [PMID: 35397309 DOI: 10.1016/j.jmr.2022.107209] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Revised: 03/24/2022] [Accepted: 03/26/2022] [Indexed: 06/14/2023]
Abstract
This work performs a detailed assessment of radiofrequency (RF) safety and imaging performance of a volumetric wireless coil based on periodically coupled split-loop resonators (SLRs) for 1.5 T wrist MRI versus a commercially available transceive extremity coil. In particular, we evaluated the transmit efficiency and RF safety for three setups: a whole-body birdcage coil, a transceive extremity birdcage coil, and a volumetric wireless coil inductively coupled to the whole-body birdcage coil. The imaging performance of the two latter setups was studied experimentally for nine subjects. The signal-to-noise ratio (SNR) of the images acquired with several standard pulse sequences for osteoarthritis wrist imaging was assessed. Application of the wireless coil significantly improved the specific absorption rate (SAR) efficiency of the whole-body birdcage coil, with at least 4.3-fold and 7.6-fold improvement of local and global SAR efficiencies, respectively. This setup also outperformed the transceive extremity coil in terms of SNR (up to 1.40-fold gain) with a moderate (11%) reduction of the local SAR efficiency.
Collapse
Affiliation(s)
- Ekaterina Brui
- School of Physics and Engineering, ITMO University, St. Petersburg, Russia
| | - Anna Mikhailovskaya
- School of Physics and Engineering, ITMO University, St. Petersburg, Russia; School of Electrical Engineering, Tel Aviv University, Tel Aviv, Israel
| | - Georgiy Solomakha
- School of Physics and Engineering, ITMO University, St. Petersburg, Russia
| | - Alexander Efimtcev
- School of Physics and Engineering, ITMO University, St. Petersburg, Russia; Department of Radiology, Federal Almazov North-West Medical Research Center, St. Petersburg, Russia
| | - Anna Andreychenko
- School of Physics and Engineering, ITMO University, St. Petersburg, Russia; Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Health Care Department, Moscow, Russia
| | - Alena Shchelokova
- School of Physics and Engineering, ITMO University, St. Petersburg, Russia.
| |
Collapse
|
13
|
Cui K, Zhang Y, Chen G, Cui Y, Wu W, Zhao N, Liu T, Xiao Z. Molecular Regulation of Polymeric Raman Probes for Ultrasensitive Microtumor Diagnosis and Noninvasive Microvessle Imaging. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2022; 18:e2106925. [PMID: 35092156 DOI: 10.1002/smll.202106925] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2021] [Revised: 12/27/2021] [Indexed: 06/14/2023]
Abstract
Raman imaging is a powerful tool for the diagnosis of cancers and visualization of various biological processes. Polymers possessing excellent biocompatibility are promising probes for Raman imaging. However, few polymers are reported to serve as Raman probes for in vivo imaging, mainly due to the intrinsic weak Raman signal intensity and fluorescence interference of these polymers. Herein, a poly(indacenodithiophene-benzothiadiazole) (IDT-BT) polymer is presented, which emits unprecedentedly strong Raman signals under the near-infrared wavelength (785 nm) excitation, thus functioning as a Raman probe for ultrasensitive in vivo Raman imaging. Further mechanistic studies unveil that the unique Raman feature of the IDT-BT polymer relies on molecularly regulating its absorbance edge adjacent to the desired excitation wavelength, thus avoiding fluorescence interference and simultaneously emitting strong Raman scattering under preresonant excitation. Taking advantage of this discipline, the IDT-BT polymeric probe successfully realizes intraoperative Raman imaging of micrometastasis as small as 0.3 mm × 0.3 mm, comparable to the most sensitive Raman probes currently reported. Impressively, the IDT-BT enables noninvasive microvascular imaging, which is not achieved using other Raman probes. This work opens a new avenue toward the development of polymeric Raman probes for in vivo Raman imaging.
Collapse
Affiliation(s)
- Kai Cui
- Department of Pharmacology and Chemical Biology, Institute of Molecular Medicine, Shanghai Key Laboratory for Nucleic Acid Chemistry and Nanomedicine, Key Laboratory of Cell Differentiation and Apoptosis of Chinese Ministry of Education, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, P. R. China
| | - Yongming Zhang
- Department of Pharmacology and Chemical Biology, Institute of Molecular Medicine, Shanghai Key Laboratory for Nucleic Acid Chemistry and Nanomedicine, Key Laboratory of Cell Differentiation and Apoptosis of Chinese Ministry of Education, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, P. R. China
| | - Gaoxian Chen
- Department of Pharmacology and Chemical Biology, Institute of Molecular Medicine, Shanghai Key Laboratory for Nucleic Acid Chemistry and Nanomedicine, Key Laboratory of Cell Differentiation and Apoptosis of Chinese Ministry of Education, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, P. R. China
| | - Yanna Cui
- Department of Pharmacology and Chemical Biology, Institute of Molecular Medicine, Shanghai Key Laboratory for Nucleic Acid Chemistry and Nanomedicine, Key Laboratory of Cell Differentiation and Apoptosis of Chinese Ministry of Education, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, P. R. China
| | - Wenwei Wu
- Department of Pharmacology and Chemical Biology, Institute of Molecular Medicine, Shanghai Key Laboratory for Nucleic Acid Chemistry and Nanomedicine, Key Laboratory of Cell Differentiation and Apoptosis of Chinese Ministry of Education, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, P. R. China
| | - Na Zhao
- Department of Pharmacology and Chemical Biology, Institute of Molecular Medicine, Shanghai Key Laboratory for Nucleic Acid Chemistry and Nanomedicine, Key Laboratory of Cell Differentiation and Apoptosis of Chinese Ministry of Education, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, P. R. China
| | - Tize Liu
- Department of Pharmacology and Chemical Biology, Institute of Molecular Medicine, Shanghai Key Laboratory for Nucleic Acid Chemistry and Nanomedicine, Key Laboratory of Cell Differentiation and Apoptosis of Chinese Ministry of Education, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, P. R. China
| | - Zeyu Xiao
- Department of Pharmacology and Chemical Biology, Institute of Molecular Medicine, Shanghai Key Laboratory for Nucleic Acid Chemistry and Nanomedicine, Key Laboratory of Cell Differentiation and Apoptosis of Chinese Ministry of Education, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, P. R. China
| |
Collapse
|
14
|
Seo JH, Chung JY. A Preliminary Study for Reference RF Coil at 11.7 T MRI: Based on Electromagnetic Field Simulation of Hybrid-BC RF Coil According to Diameter and Length at 3.0, 7.0 and 11.7 T. SENSORS 2022; 22:s22041512. [PMID: 35214409 PMCID: PMC8875900 DOI: 10.3390/s22041512] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/12/2022] [Revised: 02/13/2022] [Accepted: 02/14/2022] [Indexed: 02/05/2023]
Abstract
Magnetic resonance imaging (MRI) systems must undergo quantitative evaluation through daily and periodic performance assessments. In general, the reference or standard radiofrequency (RF) coils for these performance assessments of 1.5 to 7.0 T MRI systems have been low-pass-type birdcage (LP-BC) RF coils. However, LP-BC RF coils are inappropriate for use as reference RF coils because of their relatively lower magnetic field (B1-field) sensitivity than other types of BC RF coils, especially in ultrahigh-field (UHF) MRI systems above 3.0 T. Herein, we propose a hybrid-type BC (Hybrid-BC) RF coil as a reference RF coil with improved B1-field sensitivity in UHF MRI system and applied it to an 11.7 T MRI system. An electromagnetic field (EM-field) analysis on the Hybrid-BC RF coil was performed to provide the proper dimensions for its use as a reference RF coil. Commercial finite difference time-domain program was used in EM-field simulation, and home-made analysis programs were used in analysis. The optimal specifications of the proposed Hybrid-BC RF coils for them to qualify as reference RF coils are proposed based on their B1+-field sensitivity under unnormalized conditions, as well as by considering their B1+-field uniformity and RF safety under normalized conditions.