1
|
Ji A, Davies J, Phan PT, Nguyen CC, Sharma B, Zhu K, Nicotra E, Wan J, Phan H, Hayward C, Lovell NH, Do TN. Development of a Self-Deploying Extra-Aortic Compression Device for Medium-Term Hemodynamic Stabilization: A Feasibility Study. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2025; 12:e2412120. [PMID: 39731354 PMCID: PMC11923917 DOI: 10.1002/advs.202412120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2024] [Revised: 12/15/2024] [Indexed: 12/29/2024]
Abstract
Hemodynamic stabilization is crucial in managing acute cardiac events, where compromised blood flow can lead to severe complications and increased mortality. Conditions like decompensated heart failure (HF) and cardiogenic shock require rapid and effective hemodynamic support. Current mechanical assistive devices, such as intra-aortic balloon pumps (IABP) and extracorporeal membrane oxygenation (ECMO), offer temporary stabilization but are limited to short-term use due to risks associated with prolonged blood contact. This research presents a novel proof-of-concept soft robotic device designed with the aim of achieving low-risk, medium-term counterpulsation therapy. The device employs a nature-inspired growing mechanism for potentially minimally invasive deployment around the ascending aorta, coupled with hydraulic artificial muscles for aortic compression. It demonstrated a maximum stroke volume of 16.48 ± 0.21 mL (SD, n = 5), outperforming all other non-pneumatic extra-aortic devices. In addition, in vitro tests with a mock circulation loop (MCL) show a drop in aortic end-diastolic pressure by 6.32 mmHg and enhance coronary flow under mild aortic stenosis, which attenuate the device's assistive effect. These findings highlight the device's strong potential for optimization as a promising solution to improve outcomes for hemodynamically unstable HF patients.
Collapse
Affiliation(s)
- Adrienne Ji
- Graduate School of Biomedical Engineering, Faculty of Engineering, and Tyree Institute of Health Engineering (IHealthE)UNSW SydneyKensington CampusSydneyNSW2052Australia
| | - James Davies
- Graduate School of Biomedical Engineering, Faculty of Engineering, and Tyree Institute of Health Engineering (IHealthE)UNSW SydneyKensington CampusSydneyNSW2052Australia
| | - Phuoc Thien Phan
- Graduate School of Biomedical Engineering, Faculty of Engineering, and Tyree Institute of Health Engineering (IHealthE)UNSW SydneyKensington CampusSydneyNSW2052Australia
| | - Chi Cong Nguyen
- Graduate School of Biomedical Engineering, Faculty of Engineering, and Tyree Institute of Health Engineering (IHealthE)UNSW SydneyKensington CampusSydneyNSW2052Australia
| | - Bibhu Sharma
- Graduate School of Biomedical Engineering, Faculty of Engineering, and Tyree Institute of Health Engineering (IHealthE)UNSW SydneyKensington CampusSydneyNSW2052Australia
| | - Kefan Zhu
- Graduate School of Biomedical Engineering, Faculty of Engineering, and Tyree Institute of Health Engineering (IHealthE)UNSW SydneyKensington CampusSydneyNSW2052Australia
| | - Emanuele Nicotra
- Graduate School of Biomedical Engineering, Faculty of Engineering, and Tyree Institute of Health Engineering (IHealthE)UNSW SydneyKensington CampusSydneyNSW2052Australia
| | - Jingjing Wan
- Graduate School of Biomedical Engineering, Faculty of Engineering, and Tyree Institute of Health Engineering (IHealthE)UNSW SydneyKensington CampusSydneyNSW2052Australia
| | - Hoang‐Phuong Phan
- School of Mechanical and Manufacturing EngineeringFaculty of EngineeringUNSW SydneyKensington CampusSydneyNSW2052Australia
| | - Christopher Hayward
- Department of CardiologySt Vincent's HospitalSydneyNSW2010Australia
- St Vincent's Clinical SchoolFaculty of MedicineUNSWSydneyNSW2052Australia
| | - Nigel H. Lovell
- Graduate School of Biomedical Engineering, Faculty of Engineering, and Tyree Institute of Health Engineering (IHealthE)UNSW SydneyKensington CampusSydneyNSW2052Australia
| | - Thanh Nho Do
- Graduate School of Biomedical Engineering, Faculty of Engineering, and Tyree Institute of Health Engineering (IHealthE)UNSW SydneyKensington CampusSydneyNSW2052Australia
| |
Collapse
|
2
|
Cheng Y, Lu Y. Physical stimuli-responsive polymeric patches for healthcare. Bioact Mater 2025; 43:342-375. [PMID: 39399837 PMCID: PMC11470481 DOI: 10.1016/j.bioactmat.2024.08.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2024] [Revised: 08/21/2024] [Accepted: 08/24/2024] [Indexed: 10/15/2024] Open
Abstract
Many chronic diseases have become severe public health problems with the development of society. A safe and efficient healthcare method is to utilize physical stimulus-responsive polymer patches, which may respond to physical stimuli, including light, electric current, temperature, magnetic field, mechanical force, and ultrasound. Under certain physical stimuli, these patches have been widely used in therapy for diabetes, cancer, wounds, hair loss, obesity, and heart diseases since they could realize controllable treatment and reduce the risks of side effects. This review sketches the design principles of polymer patches, including composition, properties, and performances. Besides, control methods of using different kinds of physical stimuli were introduced. Then, the fabrication methods and characterization of patches were explored. Furthermore, recent applications of these patches in the biomedical field were demonstrated. Finally, we discussed the challenges and prospects for its clinical translation. We anticipate that physical stimulus-responsive polymer patches will open up new avenues for healthcare by acting as a platform with multiple functions.
Collapse
Affiliation(s)
- Yifan Cheng
- Department of Chemical Engineering, Tsinghua University, Beijing, 100084, China
- Key Laboratory of Industrial Biocatalysis, Ministry of Education, Tsinghua University, Beijing, 100084, China
| | - Yuan Lu
- Department of Chemical Engineering, Tsinghua University, Beijing, 100084, China
- Key Laboratory of Industrial Biocatalysis, Ministry of Education, Tsinghua University, Beijing, 100084, China
| |
Collapse
|
3
|
Masiero F, Sinibaldi E. Exact and Computationally Robust Solutions for Cylindrical Magnets Systems with Programmable Magnetization. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2023; 10:e2301033. [PMID: 37460392 PMCID: PMC10477869 DOI: 10.1002/advs.202301033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Indexed: 09/06/2023]
Abstract
Magnetic systems based on permanent magnets are receiving growing attention, in particular for micro/millirobotics and biomedical applications. Their design landscape is expanded by the possibility to program magnetization, yet enabling analytical results, crucial for containing computational costs, are lacking. The dipole approximation is systematically used (and often strained), because exact and computationally robust solutions are to be unveiled even for common geometries such as cylindrical magnets, which are ubiquitously used in fundamental research and applications. In this study, exact solutions are disclosed for magnetic field and gradient of a cylindrical magnet with generic uniform magnetization, which can be robustly computed everywhere within and outside the magnet, and directly extend to magnets systems of arbitrary complexity. Based on them, exact and computationally robust solutions are unveiled for force and torque between coaxial magnets. The obtained analytical solutions overstep the dipole approximation, thus filling a long-standing gap, and offer strong computational gains versus numerical simulations (up to 106 , for the considered test-cases). Moreover, they bridge to a variety of applications, as illustrated through a compact magnets array that could be used to advance state-of-the-art biomedical tools, by creating, based on programmable magnetization patterns, circumferential and helical force traps for magnetoresponsive diagnostic/therapeutic agents.
Collapse
Affiliation(s)
- Federico Masiero
- Biorobotics InstituteScuola Superiore Sant'Annaviale Rinaldo Piaggio 34Pontedera56025Italy
- Department of Excellence in Robotics and AIScuola Superiore Sant'Annapiazza Martiri della Libertà 33Pisa56127Italy
| | | |
Collapse
|
4
|
Jen N, Hadfield J, Bessa GM, Amabili M, Nobes DS, Chung HJ. Jacketed elastomeric tubes for passive self-regulation of pulsatile flow. J Mech Behav Biomed Mater 2023; 145:105994. [PMID: 37418970 DOI: 10.1016/j.jmbbm.2023.105994] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 06/22/2023] [Accepted: 06/24/2023] [Indexed: 07/09/2023]
Abstract
Regulating pulsatile flow is important to achieve optimal separation and mixing and enhanced heat transfer in microfluidic devices, as well as maintaining homeostasis in biological systems. The human aorta, a composite and layered tube made (among others) of elastin and collagen, is an inspiration for researchers who seek an engineering solution for a self-regulation of pulsatile flow. Here, we present a bio-inspired approach showing that fabric-jacketed elastomeric tubes, manufactured using commercially available silicone rubber and knitted textiles, can be used to regulate pulsatile flow. Our tubes are evaluated via incorporation into a mock-circulatory 'flow loop' that replicates the pulsatile fluid flow conditions of an ex-vivo heart perfusion (EVHP) device, a machine used in heart transplants. Pressure waveforms measured near the elastomeric tubing clearly indicated an effective flow regulation. The 'dynamic stiffening' behavior of the tubes during deformation is analyzed quantitatively. Broadly, the fabric jackets allow for the tubes to experience greater magnitudes of pressure and distension without risk of asymmetric aneurysm within the expected operating time of an EVHP. Owing to its highly tunable nature, our design may serve as a basis for tubing systems that require passive self-regulation of pulsatile flow.
Collapse
Affiliation(s)
- Nathan Jen
- Department of Chemical and Materials Engineering, University of Alberta, Edmonton, AB, Canada
| | - Jake Hadfield
- Department of Mechanical Engineering, University of Alberta, Edmonton, AB, Canada
| | - Guilherme M Bessa
- Department of Mechanical Engineering, University of Alberta, Edmonton, AB, Canada
| | - Marco Amabili
- Department of Mechanical Engineering, McGill University, Montreal, QC, Canada
| | - David S Nobes
- Department of Mechanical Engineering, University of Alberta, Edmonton, AB, Canada.
| | - Hyun-Joong Chung
- Department of Chemical and Materials Engineering, University of Alberta, Edmonton, AB, Canada.
| |
Collapse
|
5
|
Untethered: using remote magnetic fields for regenerative medicine. Trends Biotechnol 2022; 41:615-631. [PMID: 36220708 DOI: 10.1016/j.tibtech.2022.09.003] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Revised: 08/28/2022] [Accepted: 09/08/2022] [Indexed: 11/20/2022]
Abstract
Magnetic fields are increasingly being used for the remote, noncontact manipulation of cells and biomaterials for a wide range of regenerative medical (RM) applications. They have been deployed for their direct effects on biological systems or in conjunction with magnetic materials or magnetically tagged cells for a targeted therapeutic effect. In this work, we highlight the recent trends on the broad use of magnetic fields for the homing of therapeutic cells and particles at targeted tissue sites, biomimetic tissue fabrication, and control of cell fate and proliferation. We also survey the design and control principles of magnetic manipulation systems, including their capabilities and limitations, which can guide future research into developing more effective magnetic field-based regenerative strategies.
Collapse
|
6
|
Bonnemain J, Del Nido PJ, Roche ET. Direct Cardiac Compression Devices to Augment Heart Biomechanics and Function. Annu Rev Biomed Eng 2022; 24:137-156. [PMID: 35395165 DOI: 10.1146/annurev-bioeng-110220-025309] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The treatment of end-stage heart failure has evolved substantially with advances in medical treatment, cardiac transplantation, and mechanical circulatory support (MCS) devices such as left ventricular assist devices and total artificial hearts. However, current MCS devices are inherently blood contacting and can lead to potential complications including pump thrombosis, hemorrhage, stroke, and hemolysis. Attempts to address these issues and avoid blood contact led to the concept of compressing the failing heart from the epicardial surface and the design of direct cardiac compression (DCC) devices. We review the fundamental concepts related to DCC, present the foundational devices and recent devices in the research and commercialization stages, and discuss the milestones required for clinical translation and adoption of this technology. Expected final online publication date for the Annual Review of Biomedical Engineering, Volume 24 is June 2022. Please see http://www.annualreviews.org/page/journal/pubdates for revised estimates.
Collapse
Affiliation(s)
- Jean Bonnemain
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA.,Department of Adult Intensive Care Medicine, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland;
| | - Pedro J Del Nido
- Department of Cardiac Surgery, Boston Children's Hospital, Boston, Massachusetts, USA;
| | - Ellen T Roche
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA.,Department of Mechanical Engineering and Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA;
| |
Collapse
|
7
|
Qi J, Chen Z, Jiang P, Hu W, Wang Y, Zhao Z, Cao X, Zhang S, Tao R, Li Y, Fang D. Recent Progress in Active Mechanical Metamaterials and Construction Principles. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2022; 9:e2102662. [PMID: 34716676 PMCID: PMC8728820 DOI: 10.1002/advs.202102662] [Citation(s) in RCA: 44] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2021] [Revised: 08/31/2021] [Indexed: 05/03/2023]
Abstract
Active mechanical metamaterials (AMMs) (or smart mechanical metamaterials) that combine the configurations of mechanical metamaterials and the active control of stimuli-responsive materials have been widely investigated in recent decades. The elaborate artificial microstructures of mechanical metamaterials and the stimulus response characteristics of smart materials both contribute to AMMs, making them achieve excellent properties beyond the conventional metamaterials. The micro and macro structures of the AMMs are designed based on structural construction principles such as, phase transition, strain mismatch, and mechanical instability. Considering the controllability and efficiency of the stimuli-responsive materials, physical fields such as, the temperature, chemicals, light, electric current, magnetic field, and pressure have been adopted as the external stimuli in practice. In this paper, the frontier works and the latest progress in AMMs from the aspects of the mechanics and materials are reviewed. The functions and engineering applications of the AMMs are also discussed. Finally, existing issues and future perspectives in this field are briefly described. This review is expected to provide the basis and inspiration for the follow-up research on AMMs.
Collapse
Affiliation(s)
- Jixiang Qi
- State Key Laboratory of Explosion Science and TechnologyBeijing Institute of TechnologyBeijing100081China
- Beijing Key Laboratory of Lightweight Multi‐functional Composite Materials and StructuresInstitute of Advanced Structure TechnologyBeijing Institute of TechnologyBeijing100081China
| | - Zihao Chen
- State Key Laboratory of Explosion Science and TechnologyBeijing Institute of TechnologyBeijing100081China
- Beijing Key Laboratory of Lightweight Multi‐functional Composite Materials and StructuresInstitute of Advanced Structure TechnologyBeijing Institute of TechnologyBeijing100081China
| | - Peng Jiang
- State Key Laboratory of Explosion Science and TechnologyBeijing Institute of TechnologyBeijing100081China
- Beijing Key Laboratory of Lightweight Multi‐functional Composite Materials and StructuresInstitute of Advanced Structure TechnologyBeijing Institute of TechnologyBeijing100081China
| | - Wenxia Hu
- Beijing Key Laboratory of Lightweight Multi‐functional Composite Materials and StructuresInstitute of Advanced Structure TechnologyBeijing Institute of TechnologyBeijing100081China
| | - Yonghuan Wang
- State Key Laboratory of Explosion Science and TechnologyBeijing Institute of TechnologyBeijing100081China
- Beijing Key Laboratory of Lightweight Multi‐functional Composite Materials and StructuresInstitute of Advanced Structure TechnologyBeijing Institute of TechnologyBeijing100081China
| | - Zeang Zhao
- Beijing Key Laboratory of Lightweight Multi‐functional Composite Materials and StructuresInstitute of Advanced Structure TechnologyBeijing Institute of TechnologyBeijing100081China
| | - Xiaofei Cao
- State Key Laboratory of Explosion Science and TechnologyBeijing Institute of TechnologyBeijing100081China
- Beijing Key Laboratory of Lightweight Multi‐functional Composite Materials and StructuresInstitute of Advanced Structure TechnologyBeijing Institute of TechnologyBeijing100081China
| | - Shushan Zhang
- State Key Laboratory of Explosion Science and TechnologyBeijing Institute of TechnologyBeijing100081China
- Beijing Key Laboratory of Lightweight Multi‐functional Composite Materials and StructuresInstitute of Advanced Structure TechnologyBeijing Institute of TechnologyBeijing100081China
| | - Ran Tao
- Beijing Key Laboratory of Lightweight Multi‐functional Composite Materials and StructuresInstitute of Advanced Structure TechnologyBeijing Institute of TechnologyBeijing100081China
| | - Ying Li
- State Key Laboratory of Explosion Science and TechnologyBeijing Institute of TechnologyBeijing100081China
- Beijing Key Laboratory of Lightweight Multi‐functional Composite Materials and StructuresInstitute of Advanced Structure TechnologyBeijing Institute of TechnologyBeijing100081China
| | - Daining Fang
- Beijing Key Laboratory of Lightweight Multi‐functional Composite Materials and StructuresInstitute of Advanced Structure TechnologyBeijing Institute of TechnologyBeijing100081China
| |
Collapse
|