1
|
Shahriari S, Sastry M, Panjikar S, Singh Raman RK. Graphene and Graphene Oxide as a Support for Biomolecules in the Development of Biosensors. Nanotechnol Sci Appl 2021; 14:197-220. [PMID: 34815666 PMCID: PMC8605898 DOI: 10.2147/nsa.s334487] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2021] [Accepted: 10/02/2021] [Indexed: 01/21/2023] Open
Abstract
Graphene and graphene oxide have become the base of many advanced biosensors due to their exceptional characteristics. However, lack of some properties, such as inertness of graphene in organic solutions and non-electrical conductivity of graphene oxide, are their drawbacks in sensing applications. To compensate for these shortcomings, various methods of modifications have been developed to provide the appropriate properties required for biosensing. Efficient modification of graphene and graphene oxide facilitates the interaction of biomolecules with their surface, and the ultimate bioconjugate can be employed as the main sensing part of the biosensors. Graphene nanomaterials as transducers increase the signal response in various sensing applications. Their large surface area and perfect biocompatibility with lots of biomolecules provide the prerequisite of a stable biosensor, which is the immobilization of bioreceptor on transducer. Biosensor development has paramount importance in the field of environmental monitoring, security, defense, food safety standards, clinical sector, marine sector, biomedicine, and drug discovery. Biosensor applications are also prevalent in the plant biology sector to find the missing links required in the metabolic process. In this review, the importance of oxygen functional groups in functionalizing the graphene and graphene oxide and different types of functionalization will be explained. Moreover, immobilization of biomolecules (such as protein, peptide, DNA, aptamer) on graphene and graphene oxide and at the end, the application of these biomaterials in biosensors with different transducing mechanisms will be discussed.
Collapse
Affiliation(s)
- Shiva Shahriari
- Department of Mechanical & Aerospace Engineering, Monash University, Melbourne, Victoria, Australia
| | - Murali Sastry
- Department of Materials Science and Engineering, Monash University, Melbourne, Victoria, Australia
| | - Santosh Panjikar
- ANSTO, Australian Synchrotron, Melbourne, Victoria, Australia
- Department of Molecular Biology and Biochemistry, Monash University, Melbourne, Victoria, Australia
| | - R K Singh Raman
- Department of Mechanical & Aerospace Engineering, Monash University, Melbourne, Victoria, Australia
| |
Collapse
|
2
|
Probing the influence of graphene oxide sheets size on the performance of label-free electrochemical biosensors. Sci Rep 2020; 10:13612. [PMID: 32788744 PMCID: PMC7424566 DOI: 10.1038/s41598-020-70384-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2018] [Accepted: 07/28/2020] [Indexed: 11/08/2022] Open
Abstract
The integration of graphene materials into electrochemical biosensing platforms has gained significant interest in recent years. Bulk quantities of graphene can be synthesized by oxidation of graphite to graphite oxide and subsequent exfoliation to graphene oxide (GO). However, the size of the resultant GO sheets changes from the parent graphite yielding a polydispersed solution of sizes ranging from a few nanometers to tens of micrometers. Here, we investigate the direct effect of GO sheets sizes on biosensor performance. We separated different GO sheets sizes, and we characterized them via atomic force, scanning electron, Raman and X-ray photoelectron spectroscopies and solid state nuclear magnetic resonance (NMR). As proof of concept, the sensing performance of these GO samples was probed using a well-known ssDNA aptasensor against microcystin-LR toxin and an immunosensor against β-lactoglobulin. The resulting aptasensors and immunosensors are fabricated by using covalent attachment and physical adsorption. We found that the aptasensors fabricated using physical adsorption, the binding signal variation was dramatically increased with increasing the GO sheet size. In contrast, for the aptasensor fabricated using covalent immobilization, the binding signal variation decreased with increasing GO sheet size. However, for the β-lactoglobulin immunosensors, the optimum signals were observed at intermediate GO sheet size. GO sheet size could enhance or inhibit the sensitivity of the graphene-based electrochemical sensors. Our results demonstrate that controlling the size of GO sheets may have a profound impact in specific biosensing applications.
Collapse
|
3
|
Bonanni A. Advances on the Use of Graphene as a Label for Electrochemical Biosensors. ChemElectroChem 2020. [DOI: 10.1002/celc.202000521] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Affiliation(s)
- Alessandra Bonanni
- Division of Chemistry & Biological Chemistry School of Physical and Mathematical Sciences Nanyang Technological University Singapore 637371
| |
Collapse
|
4
|
Shellard PM, Srisubin T, Hartmann M, Butcher J, Fei F, Cox H, McNamara TP, McArdle T, Shepherd AM, Jacobs RMJ, Waigh TA, Flitsch SL, Blanford CF. A versatile route to edge-specific modifications to pristine graphene by electrophilic aromatic substitution. JOURNAL OF MATERIALS SCIENCE 2020; 55:10284-10302. [PMID: 32536720 PMCID: PMC7266800 DOI: 10.1007/s10853-020-04662-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/18/2020] [Accepted: 04/07/2020] [Indexed: 06/11/2023]
Abstract
Electrophilic aromatic substitution produces edge-specific modifications to CVD graphene and graphene nanoplatelets that are suitable for specific attachment of biomolecules.
Collapse
Affiliation(s)
- Philippa M. Shellard
- Department of Chemistry, University of Manchester, Oxford Road, Manchester, M13 9PL UK
- Manchester Institute of Biotechnology, University of Manchester, 131 Princess Street, Manchester, M1 7DN UK
| | - Thunyaporn Srisubin
- Manchester Institute of Biotechnology, University of Manchester, 131 Princess Street, Manchester, M1 7DN UK
- Department of Materials, University of Manchester, Oxford Road, Manchester, M13 9PL UK
| | - Mirja Hartmann
- Department of Chemistry, University of Manchester, Oxford Road, Manchester, M13 9PL UK
- Manchester Institute of Biotechnology, University of Manchester, 131 Princess Street, Manchester, M1 7DN UK
| | - Joseph Butcher
- Department of Chemistry, University of Manchester, Oxford Road, Manchester, M13 9PL UK
- Manchester Institute of Biotechnology, University of Manchester, 131 Princess Street, Manchester, M1 7DN UK
| | - Fan Fei
- Manchester Institute of Biotechnology, University of Manchester, 131 Princess Street, Manchester, M1 7DN UK
- Department of Materials, University of Manchester, Oxford Road, Manchester, M13 9PL UK
| | - Henry Cox
- Biological Physics, Department of Physics and Astronomy, University of Manchester, Oxford Road, Manchester, M13 9PL UK
- Photon Science Institute, University of Manchester, Alan Turing Building, Oxford Road, Manchester, M13 9PL UK
| | - Thomas P. McNamara
- Manchester Institute of Biotechnology, University of Manchester, 131 Princess Street, Manchester, M1 7DN UK
- Department of Materials, University of Manchester, Oxford Road, Manchester, M13 9PL UK
| | - Trevor McArdle
- Manchester Institute of Biotechnology, University of Manchester, 131 Princess Street, Manchester, M1 7DN UK
- Department of Materials, University of Manchester, Oxford Road, Manchester, M13 9PL UK
| | - Ashley M. Shepherd
- Chemical Research Laboratory, Department of Chemistry, University of Oxford, 12 Mansfield Road, Oxford, OX1 3TA UK
| | - Robert M. J. Jacobs
- Chemical Research Laboratory, Department of Chemistry, University of Oxford, 12 Mansfield Road, Oxford, OX1 3TA UK
| | - Thomas A. Waigh
- Biological Physics, Department of Physics and Astronomy, University of Manchester, Oxford Road, Manchester, M13 9PL UK
- Photon Science Institute, University of Manchester, Alan Turing Building, Oxford Road, Manchester, M13 9PL UK
| | - Sabine L. Flitsch
- Department of Chemistry, University of Manchester, Oxford Road, Manchester, M13 9PL UK
- Manchester Institute of Biotechnology, University of Manchester, 131 Princess Street, Manchester, M1 7DN UK
| | - Christopher F. Blanford
- Manchester Institute of Biotechnology, University of Manchester, 131 Princess Street, Manchester, M1 7DN UK
- Department of Materials, University of Manchester, Oxford Road, Manchester, M13 9PL UK
| |
Collapse
|
5
|
Park JH, Ferhan AR, Jackman JA, Cho NJ. Modulating conformational stability of human serum albumin and implications for surface passivation applications. Colloids Surf B Biointerfaces 2019; 180:306-312. [DOI: 10.1016/j.colsurfb.2019.04.017] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2019] [Accepted: 04/08/2019] [Indexed: 12/11/2022]
|
6
|
Silva NFD, Magalhães JMCS, Barroso MF, Oliva-Teles T, Freire C, Delerue-Matos C. In situ formation of gold nanoparticles in polymer inclusion membrane: Application as platform in a label-free potentiometric immunosensor for Salmonella typhimurium detection. Talanta 2018; 194:134-142. [PMID: 30609512 DOI: 10.1016/j.talanta.2018.10.024] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2018] [Revised: 10/04/2018] [Accepted: 10/08/2018] [Indexed: 12/31/2022]
Abstract
Polymeric ion selective electrodes are highly sensitive to changes in zero current ion flow and this offers a route to signal amplification in label-free potentiometric immunosensors. In this work, a label-free potentiometric immunosensor toward Salmonella typhimurium (ST) assembled in a home-made pipette-tip electrode is described. The signal-output amplification was implemented on a gold nanoparticle polymer inclusion membrane (AuNPs-PIM) which was used as sensing platform and for antibody immobilization. Additionally, a marker ion was used to detect the antibody-antigen binding event at the electrode surface. The immunosensor construction was performed in several steps: i) gold salt ions extraction in PVC membrane; ii) AuNPs formation using Na2EDTA as reduction agent; iii) antibody anti-Salmonella conjugation on AuNPs-PIM in pipette-tip electrodes. The potential shift observed in potentiometric measurements was derived simply from the blocking effect in the ionic flux caused by antigen-antibody conjugation, without no extra steps, mimetizing the ion-channel sensors. A detection limit of 6 cells mL-1 was attained. As proof-of-concept, recovery studies were performed in spiked commercial apple juice samples with success. Due to the simplicity of use, the appealing cost of equipment and sensor production and being able to provide a quick analytical response (less than 1 h for a complete assay, including sample preparation for analysis), this scheme represents a good prototype device for the detection of foodborne pathogens like ST or other immune-responsive bacteria.
Collapse
Affiliation(s)
- Nádia F D Silva
- REQUIMTE/LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, 4200-072 Porto, Portugal; REQUIMTE/LAQV, Departamento de Química e Bioquímica, Faculdade de Ciências, Universidade do Porto, 4169-007 Porto, Portugal
| | - Júlia M C S Magalhães
- REQUIMTE/LAQV, Departamento de Engenharia Química, Faculdade de Engenharia, Universidade do Porto, 4200-465 Porto, Portugal.
| | - M Fátima Barroso
- REQUIMTE/LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, 4200-072 Porto, Portugal
| | - Teresa Oliva-Teles
- REQUIMTE/LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, 4200-072 Porto, Portugal
| | - Cristina Freire
- REQUIMTE/LAQV, Departamento de Química e Bioquímica, Faculdade de Ciências, Universidade do Porto, 4169-007 Porto, Portugal
| | - Cristina Delerue-Matos
- REQUIMTE/LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, 4200-072 Porto, Portugal
| |
Collapse
|
7
|
Macedo LJA, Iost RM, Hassan A, Balasubramanian K, Crespilho FN. Bioelectronics and Interfaces Using Monolayer Graphene. ChemElectroChem 2018. [DOI: 10.1002/celc.201800934] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Affiliation(s)
- Lucyano J. A. Macedo
- São Carlos Institute of Chemistry; University of São Paulo; São Carlos SP 13560-970 Brazil
| | - Rodrigo M. Iost
- Department of Chemistry School of Analytical Sciences Adlershof (SALSA) and IRIS Adlershof; Humboldt-Universität zu Berlin; Berlin 10099 Germany
| | - Ayaz Hassan
- São Carlos Institute of Chemistry; University of São Paulo; São Carlos SP 13560-970 Brazil
| | - Kannan Balasubramanian
- Department of Chemistry School of Analytical Sciences Adlershof (SALSA) and IRIS Adlershof; Humboldt-Universität zu Berlin; Berlin 10099 Germany
| | - Frank N. Crespilho
- São Carlos Institute of Chemistry; University of São Paulo; São Carlos SP 13560-970 Brazil
| |
Collapse
|
8
|
Enzyme Immobilization on Functionalized Graphene Oxide Nanosheets: Efficient and Robust Biocatalysts. Methods Enzymol 2018; 609:371-403. [DOI: 10.1016/bs.mie.2018.06.010] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/06/2022]
|
9
|
|
10
|
Saleh TA, Shuaib TD, Danmaliki GI, Al-Daous MA. Carbon-Based Nanomaterials for Desulfurization. APPLYING NANOTECHNOLOGY TO THE DESULFURIZATION PROCESS IN PETROLEUM ENGINEERING 2016. [DOI: 10.4018/978-1-4666-9545-0.ch005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
The special interest in ultra-low sulfur diesel (ULSD) is informed by the need to comply with the strict government policy on low sulfur content of transportation fuels. Better knowledge of different factors that concern deep desulfurization of fuels is important to achieve ultra-low sulfur fuels and cheaper way of producing ULSD. Both the capital and operating cost of the adsorptive desulfurization process is cheaper compare to the conventional hydroprocessing. The need to produce more volume of fuel such as diesel with very low sulfur content from low grade feed stocks like heavy oil and light cycle oil (LCO) in order to meet up with the global demand for sulfur-free fuels is pertinent. Several on-going researches are pointing to the use of adsorbents for removal of sulfur compounds from the hydrocarbon refining stream. In this chapter, varieties of carbon nanomaterials suitable for adsorptive desulfurization are discussed. The approach is feasible for commercial applications with any adsorbent of an adequate lifetime of activity as well as high capacity.
Collapse
Affiliation(s)
- Tawfik A. Saleh
- Department of Chemistry, King Fahd University of Petroleum and Minerals, Saudi Arabia
| | | | | | | |
Collapse
|
11
|
Chen J, Zhang Y, Chang J, Cheng L, Cao S. Recent advances in silica-based biosensors: a review. ACTA ACUST UNITED AC 2015. [DOI: 10.1080/22243682.2015.1088795] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
|
12
|
Karimi A, Othman A, Uzunoglu A, Stanciu L, Andreescu S. Graphene based enzymatic bioelectrodes and biofuel cells. NANOSCALE 2015; 7:6909-23. [PMID: 25832672 DOI: 10.1039/c4nr07586b] [Citation(s) in RCA: 53] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
The excellent electrical conductivity and ease of functionalization make graphene a promising material for use in enzymatic bioelectrodes and biofuel cells. Enzyme based biofuel cells have attracted substantial interest due to their potential to harvest energy from organic materials. This review provides an overview of the functional properties and applications of graphene in the construction of biofuel cells as alternative power sources. The review covers the current state-of-the-art research in graphene based nanomaterials (physicochemical properties and surface functionalities), the role of these parameters in enhancing electron transfer, the stability and activity of immobilized enzymes, and how enhanced power density can be achieved. Specific examples of enzyme immobilization methods, enzyme loading, stability and function on graphene, functionalized graphene and graphene based nanocomposite materials are discussed along with their advantages and limitations. Finally, a critical evaluation of the performance of graphene based enzymatic biofuel cells, the current status, challenges and future research needs are provided.
Collapse
Affiliation(s)
- Anahita Karimi
- Department of Chemistry and Biomolecular Science, Clarkson University, Potsdam, New York 13699-5810, USA.
| | | | | | | | | |
Collapse
|
13
|
Ping J, Zhou Y, Wu Y, Papper V, Boujday S, Marks RS, Steele TWJ. Recent advances in aptasensors based on graphene and graphene-like nanomaterials. Biosens Bioelectron 2014; 64:373-85. [PMID: 25261843 DOI: 10.1016/j.bios.2014.08.090] [Citation(s) in RCA: 106] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2014] [Revised: 08/14/2014] [Accepted: 08/27/2014] [Indexed: 11/28/2022]
Abstract
Graphene and graphene-like two-dimensional nanomaterials have aroused tremendous research interest in recent years due to their unique electronic, optical, and mechanical properties associated with their planar structure. Aptamers have exhibited many advantages as molecular recognition elements for sensing devices compared to traditional antibodies. The marriage of two-dimensional nanomaterials and aptamers has emerged many ingenious aptasensing strategies for applications in the fields of clinical diagnosis and food safety. This review highlights current advances in the development and application of two-dimensional nanomaterials-based aptasensors with the focus on two main signal-transducing mechanisms, i.e. electrochemical and optical. A special attention is paid to graphene, a one-atom thick layer of graphite with exceptional properties, representing a fastgrowing field of research. In view of the unique properties of two-dimensional nanostructures and their inherent advantages of synthetic aptamers, we expect that high-performance two-dimensional nanomaterials-based aptasensing devices will find extensive applications in environmental monitoring, biomedical diagnostics, and food safety.
Collapse
Affiliation(s)
- Jianfeng Ping
- School of Materials Science & Engineering, College of Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore
| | - Yubin Zhou
- School of Materials Science & Engineering, College of Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore
| | - Yuanyuan Wu
- School of Materials Science & Engineering, College of Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore
| | - Vladislav Papper
- School of Materials Science & Engineering, College of Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore
| | - Souhir Boujday
- Sorbonne Universités, UPMC, Univ Paris 6, UMR CNRS 7197, Laboratoire de Réactivité de Surface, F-75005 Paris, France; CNRS, UMR 7197, Laboratoire de Réactivité de Surface, F-75005 Paris, France
| | - Robert S Marks
- Department of Biotechnology Engineering, and The Ilse Katz Center for Meso and Nanoscale Science, Faculty of Engineering Sciences, Ben Gurion University of the Negev, P.O. Box 653, Beer Sheva 84105, Israel
| | - Terry W J Steele
- School of Materials Science & Engineering, College of Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore.
| |
Collapse
|
14
|
Ambrosi A, Chua CK, Bonanni A, Pumera M. Electrochemistry of Graphene and Related Materials. Chem Rev 2014; 114:7150-88. [DOI: 10.1021/cr500023c] [Citation(s) in RCA: 826] [Impact Index Per Article: 75.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Adriano Ambrosi
- Division of Chemistry & Biological Chemistry, School of Physical and Mathematical Sciences, Nanyang Technological University, Singapore 637371, Singapore
| | - Chun Kiang Chua
- Division of Chemistry & Biological Chemistry, School of Physical and Mathematical Sciences, Nanyang Technological University, Singapore 637371, Singapore
| | - Alessandra Bonanni
- Division of Chemistry & Biological Chemistry, School of Physical and Mathematical Sciences, Nanyang Technological University, Singapore 637371, Singapore
| | - Martin Pumera
- Division of Chemistry & Biological Chemistry, School of Physical and Mathematical Sciences, Nanyang Technological University, Singapore 637371, Singapore
| |
Collapse
|
15
|
Graphene-based nanobiocatalytic systems: recent advances and future prospects. Trends Biotechnol 2014; 32:312-20. [PMID: 24794165 DOI: 10.1016/j.tibtech.2014.04.004] [Citation(s) in RCA: 138] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2014] [Revised: 03/29/2014] [Accepted: 04/02/2014] [Indexed: 01/06/2023]
Abstract
Graphene-based nanomaterials are particularly useful nanostructured materials that show great promise in biotechnology and biomedicine. Owing to their unique structural features, exceptional chemical, electrical, and mechanical properties, and their ability to affect the microenvironment of biomolecules, graphene-based nanomaterials are suitable for use in various applications, such as immobilization of enzymes. We present the current advances in research on graphene-based nanomaterials used as novel scaffolds to build robust nanobiocatalytic systems. Their catalytic behavior is affected by the nature of enzyme-nanomaterial interactions and, thus, the availability of methods to couple enzymes with nanomaterials is an important issue. We discuss the implications of such interactions along with future prospects and possible challenges in this rapidly developing area.
Collapse
|
16
|
Lawrence K, Baker CL, James TD, Bull SD, Lawrence R, Mitchels JM, Opallo M, Arotiba OA, Ozoemena KI, Marken F. Functionalized Carbon Nanoparticles, Blacks and Soots as Electron-Transfer Building Blocks and Conduits. Chem Asian J 2014; 9:1226-41. [DOI: 10.1002/asia.201301657] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2013] [Indexed: 11/05/2022]
|
17
|
Balasubramanian K, Kern K. 25th anniversary article: label-free electrical biodetection using carbon nanostructures. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2014; 26:1154-75. [PMID: 24452968 DOI: 10.1002/adma.201304912] [Citation(s) in RCA: 59] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/02/2013] [Revised: 10/25/2013] [Indexed: 05/07/2023]
Abstract
Nanostructures are promising candidates for use as active materials for the detection of chemical and biological species, mainly due to the high surface-to-volume ratio and the unique physical properties arising at the nanoscale. Among the various nanostructures, materials comprised of sp(2) -carbon enjoy a unique position due to the possibility to readily prepare them in various dimensions ranging from 0D, through 1D to 2D. This review focuses on the use of 1D (carbon nanotubes) and 2D (graphene) carbon nanostructures for the detection of biologically relevant molecules. A key advantage is the possibility to perform the sensing operation without the use of any labels or complex reaction schemes. Along this spirit, various strategies reported for the label-free electrical detection of biomolecules using carbon nanostructures are discussed. With their promise for ultimate sensitivity and the capability to attain high selectivity through controlled chemical functionalization, carbon-based nanobiosensors are expected to open avenues to novel diagnostic tools as well as to obtain new fundamental insight into biomolecular interactions down to the single molecule level.
Collapse
Affiliation(s)
- Kannan Balasubramanian
- Max Planck Institute for Solid State Research, Heisenbergstrasse 1, D70569, Stuttgart, Germany
| | | |
Collapse
|
18
|
Abstract
Herein, we aim to draw attention to employing chemical vapour deposition (CVD) method grown graphene as a potential platform for immunosensing of IgG.
Collapse
Affiliation(s)
- Adeline Huiling Loo
- Division of Chemistry & Biological Chemistry
- School of Physical and Mathematical Sciences
- Nanyang Technological University
- , Singapore
| | - Adriano Ambrosi
- Division of Chemistry & Biological Chemistry
- School of Physical and Mathematical Sciences
- Nanyang Technological University
- , Singapore
| | - Alessandra Bonanni
- Division of Chemistry & Biological Chemistry
- School of Physical and Mathematical Sciences
- Nanyang Technological University
- , Singapore
| | - Martin Pumera
- Division of Chemistry & Biological Chemistry
- School of Physical and Mathematical Sciences
- Nanyang Technological University
- , Singapore
| |
Collapse
|
19
|
Loo AH, Bonanni A, Pumera M. Inherently electroactive graphene oxide nanoplatelets as labels for specific protein-target recognition. NANOSCALE 2013; 5:7844-7848. [PMID: 23846404 DOI: 10.1039/c3nr02101g] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Graphene related materials have been widely employed as highly efficient transducers for biorecognition. Here we show a conceptually new approach of using graphene oxide nanoplatelets (50 × 50 nm) as voltammetric inherently active labels for specific protein-target molecule recognition. This proof-of-principle is demonstrated by biotin-avidin recognition, which displays that graphene oxide nanoplatelet labels show excellent selectivity. Therefore, it is expected that inherently electroactive graphene oxide nanoplatelet labels will play a similar role as electroactive gold nanoparticle labels which were developed more than a decade ago.
Collapse
Affiliation(s)
- Adeline Huiling Loo
- Division of Chemistry & Biological Chemistry, School of Physical and Mathematical Sciences, Nanyang Technological University, Singapore 637371, Singapore
| | | | | |
Collapse
|
20
|
Loo AH, Bonanni A, Pumera M. Thrombin aptasensing with inherently electroactive graphene oxide nanoplatelets as labels. NANOSCALE 2013; 5:4758-4762. [PMID: 23604556 DOI: 10.1039/c3nr00511a] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Graphene and its associated materials are commonly used as the transducing platform in biosensing. We propose a different approach for the application of graphene in biosensing. Here, we utilized graphene oxide nanoplatelets as the inherently electroactive labels for the aptasensing of thrombin. The basis of detection lies in the ability of graphene oxide to be electrochemically reduced, thereby providing a well-defined reduction wave; one graphene oxide nanoplatelet of dimension 50 × 50 nm can provide a reduction signal by accepting ~22,000 electrons. We demonstrate that by using graphene oxide nanoplatelets as an inherently electroactive label, we can detect thrombin in the concentration range of 3 pM-0.3 μM, with good selectivity of the aptamer towards interferences by bovine serum albumin, immunoglobulin G and avidin. Therefore, the inherently electroactive graphene oxide nanoplatelets are a material which can serve as an electroactive label, in a manner similar to metallic nanoparticles.
Collapse
Affiliation(s)
- Adeline Huiling Loo
- Division of Chemistry & Biological Chemistry, School of Physical and Mathematical Sciences, Nanyang Technological University, Singapore, 637371, Singapore
| | | | | |
Collapse
|
21
|
Wang Q, Ding Y, Wang L, Ni J, Yu Z, Lin H, Gao F. Low-Background, Highly Sensitive DNA Biosensor by Using an Electrically Neutral Cobalt(II) Complex as the Redox Hybridization Indicator. Chem Asian J 2013; 8:1455-62. [DOI: 10.1002/asia.201300047] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2013] [Revised: 03/07/2013] [Indexed: 11/10/2022]
|