1
|
Shenoy KG. Enhanced view totally extraperitoneal approach: The best available option for recurrent incisional hernias following previous laparoscopic intraperitoneal onlay mesh plus repairs. J Minim Access Surg 2025; 21:217-222. [PMID: 39388123 PMCID: PMC12054960 DOI: 10.4103/jmas.jmas_152_24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2024] [Revised: 07/28/2024] [Accepted: 08/21/2024] [Indexed: 10/15/2024] Open
Abstract
ABSTRACT The available options for recurrent incisional hernias (RIH) following previous laparoscopic intraperitoneal onlay mesh (IPOM) plus were open onlay repair, open Rives-Stoppa (RS), laparoscopic enhanced view totally extraperitoneal-RS (ETEP-RS) and laparoscopic subcutaneous onlay mesh repair. Majority of these RIH were managed by open onlay mesh repairs or laparoscopic Redo IPOM plus. There are not much data available in the literature on the ETEP approach for RIH following previous IPOM plus with the placement of mesh in the retrorectus space. In this article, I would like to share technical aspects, challenges faced and tips to overcome these challenges of performing ETEP for RIH following previous IPOM plus repairs.
Collapse
Affiliation(s)
- K. Ganesh Shenoy
- Department of Minimal Access, GI and Bariatric Surgery, Fortis Hospital, Bengaluru, Karnataka, India
| |
Collapse
|
2
|
Woo KP, Ellis RC, Maskal SM, Remulla D, Shukla P, Rosen AJ, Wetzka I, Osei-Koomson W, Phillips S, Miller BT, Beffa LR, Petro CC, Krpata DM, Prabhu AS, Menzo EL, Rosen MJ. The association of permanent versus absorbable fixation on developing chronic post-herniorrhaphy groin pain in patients undergoing laparoscopic inguinal hernia repair. Surg Endosc 2024; 38:3433-3440. [PMID: 38710888 PMCID: PMC11133107 DOI: 10.1007/s00464-024-10866-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Accepted: 04/14/2024] [Indexed: 05/08/2024]
Abstract
INTRODUCTION Fixation of mesh during minimally invasive inguinal hernia repair is thought to contribute to chronic post-herniorrhaphy groin pain (CGP). In contrast to permanent tacks, absorbable tacks are hypothesized to minimize the likelihood of CGP. This study aimed to compare the rates of CGP after laparoscopic inguinal hernia repair between absorbable versus permanent fixation at maximum follow-up. METHODS This is a post hoc analysis of a randomized controlled trial in patients undergoing laparoscopic inguinal hernia repair (NCT03835351). All patients were contacted at maximum follow-up after surgery to administer EuraHS quality of life (QoL) surveys. The pain and restriction of activity subdomains of the survey were utilized. The primary outcome was rate of CGP, as defined by a EuraHS QoL pain domain score ≥ 4 measured at ≥ 1 year postoperatively. The secondary outcomes were pain and restriction of activity domain scores and hernia recurrence at maximum follow-up. RESULTS A total of 338 patients were contacted at a mean follow-up of 28 ± 11 months. 181 patients received permanent tacks and 157 patients received absorbable tacks during their repair. At maximum follow-up, the rates of CGP (27 [15%] vs 28 [18%], P = 0.47), average pain scores (1.78 ± 4.38 vs 2.32 ± 5.40, P = 0.22), restriction of activity scores (1.39 ± 4.32 vs 2.48 ± 7.45, P = 0.18), and the number of patients who reported an inguinal bulge (18 [9.9%] vs 15 [9.5%], P = 0.9) were similar between patients with permanent versus absorbable tacks. On multivariable analysis, there was no significant difference in the odds of CGP between the two groups (OR 1.23, 95% CI [0.60, 2.50]). CONCLUSION Mesh fixation with permanent tacks does not appear to increase the risk of CGP after laparoscopic inguinal hernia repair when compared to fixation with absorbable tacks. Prospective trials are needed to further evaluate this relationship.
Collapse
Affiliation(s)
- Kimberly P Woo
- Department of General Surgery, Digestive Disease Institute, Cleveland Clinic, 9500 Euclid Ave, Cleveland, OH, 44195, USA.
| | - Ryan C Ellis
- Department of General Surgery, Digestive Disease Institute, Cleveland Clinic, 9500 Euclid Ave, Cleveland, OH, 44195, USA
| | - Sara M Maskal
- Department of General Surgery, Digestive Disease Institute, Cleveland Clinic, 9500 Euclid Ave, Cleveland, OH, 44195, USA
| | - Daphne Remulla
- Department of General Surgery, Digestive Disease Institute, Cleveland Clinic, 9500 Euclid Ave, Cleveland, OH, 44195, USA
| | - Priya Shukla
- Department of General Surgery, Digestive Disease Institute, Cleveland Clinic, 9500 Euclid Ave, Cleveland, OH, 44195, USA
| | - Alexandra J Rosen
- Department of General Surgery, Digestive Disease Institute, Cleveland Clinic, 9500 Euclid Ave, Cleveland, OH, 44195, USA
| | - Isabella Wetzka
- Department of General Surgery, Digestive Disease Institute, Cleveland Clinic, 9500 Euclid Ave, Cleveland, OH, 44195, USA
| | - Wilhemina Osei-Koomson
- Department of General Surgery, Digestive Disease Institute, Cleveland Clinic, 9500 Euclid Ave, Cleveland, OH, 44195, USA
| | - Sharon Phillips
- Department of Biostatistics, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Benjamin T Miller
- Department of General Surgery, Digestive Disease Institute, Cleveland Clinic, 9500 Euclid Ave, Cleveland, OH, 44195, USA
| | - Lucas R Beffa
- Department of General Surgery, Digestive Disease Institute, Cleveland Clinic, 9500 Euclid Ave, Cleveland, OH, 44195, USA
| | - Clayton C Petro
- Department of General Surgery, Digestive Disease Institute, Cleveland Clinic, 9500 Euclid Ave, Cleveland, OH, 44195, USA
| | - David M Krpata
- Department of General Surgery, Digestive Disease Institute, Cleveland Clinic, 9500 Euclid Ave, Cleveland, OH, 44195, USA
| | - Ajita S Prabhu
- Department of General Surgery, Digestive Disease Institute, Cleveland Clinic, 9500 Euclid Ave, Cleveland, OH, 44195, USA
| | - Emanuele Lo Menzo
- Department of General Surgery, Bariatric and Metabolic Institute, Cleveland Clinic Florida, Weston Hospital, Weston, FL, USA
| | - Michael J Rosen
- Department of General Surgery, Digestive Disease Institute, Cleveland Clinic, 9500 Euclid Ave, Cleveland, OH, 44195, USA
| |
Collapse
|
3
|
Hiekkaranta JM, Ahonen M, Mäkäräinen E, Saarnio J, Pinta T, Vironen J, Niemeläinen S, Vento P, Nikki M, Ohtonen P, Rautio T. Laparoscopic versus hybrid approach for treatment of incisional ventral hernia: a 5-10-year follow-up of the randomized controlled multicenter study. Hernia 2024; 28:191-197. [PMID: 37594636 PMCID: PMC10890975 DOI: 10.1007/s10029-023-02849-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Accepted: 07/23/2023] [Indexed: 08/19/2023]
Abstract
PURPOSE In this long-term follow-up of a prospective, randomized, and multicenter study, we compare the results of a group receiving laparoscopic incisional ventral hernia repair using intraperitoneal onlay mesh (LG) to a group receiving a hybrid hernia repair where open closure of fascial defect was added to intraperitoneal mesh placement (HG). METHODS Originally, 193 patients with 2-7 cm incisional hernias were randomly assigned to either the LG or HG during the 30-month recruitment period in 2012 to 2015. Long-term follow-up was conducted 5-10 years after surgery to evaluate hernia recurrence rate and quality of life (QoL). RESULTS In all, 65 patients in the LG and 60 in the HG completed the long-term follow-up with a median follow-up period of 87 months. Recurrent hernia was detected in 11 of 65 patients (16.9%) in the LG and 10 of 60 patients (16.7%) in the HG (p > 0.9). Kaplan-Meier analysis demonstrated a recurrence rate approaching 20% in both groups, with similar curves. Three patients in the LG (4.6% and five patients in the HG (8.1%) had undergone re-operation due to recurrence (p = 0.48). There was no difference in patient-reported QoL measured using the SF-36 questionnaire. Mean pain scores were similar between groups, mean numeric rating scale (NRS) 0 to 10 being 1.1 in the LG and 0.7 in the HG (p = 0.43). CONCLUSION Fascial closure did not reduce hernia recurrence rate in this study population, even though it has been shown to be beneficial and recommended in surgery guidelines. In the long term, recurrence rate for both groups is similar.
Collapse
Affiliation(s)
- J M Hiekkaranta
- Department of Surgery, Oulu University Hospital, Oulu, Finland.
| | - M Ahonen
- Department of Surgery, Oulu University Hospital, Oulu, Finland
| | - E Mäkäräinen
- Department of Surgery, Oulu University Hospital, Oulu, Finland
| | - J Saarnio
- Department of Surgery, Oulu University Hospital, Oulu, Finland
| | - T Pinta
- Department of Surgery, Seinäjoki Central Hospital, Seinäjoki, Finland
| | - J Vironen
- Department of Surgery, Helsinki University Hospital, Helsinki, Finland
| | - S Niemeläinen
- Department of Surgery, Tampere University Hospital, Tampere, Finland
| | - P Vento
- Department of Surgery, Kymenlaakso Central Hospital, Kotka, Finland
| | - M Nikki
- Department of Radiology, Oulu University Hospital, Oulu, Finland
| | - P Ohtonen
- Research Service Unit, The Research Unit of Surgery, Anesthesia and Intensive Care, Oulu University Hospital, University of Oulu, Oulu, Finland
| | - T Rautio
- Department of Surgery, Oulu University Hospital, Oulu, Finland
| |
Collapse
|
4
|
Gómez-Menchero J, Balla A, García Moreno JL, Gila Bohorquez A, Bellido-Luque JA, Morales-Conde S. Laparoscopic intracorporeal rectus aponeuroplasty (LIRA) technique versus intraperitoneal onlay mesh (IPOM plus) for ventral hernia repair: a comparative analysis. Hernia 2024; 28:167-177. [PMID: 37592164 DOI: 10.1007/s10029-023-02858-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Accepted: 08/07/2023] [Indexed: 08/19/2023]
Abstract
PURPOSE Primary aim of this study is to compare the postoperative outcomes of the laparoscopic intracorporeal rectus aponeuroplasty (LIRA) technique to the intraperitoneal onlay mesh closing the defect (IPOM plus), in terms of recurrence and bulging rates at one-year follow-up; secondary aim is to compare the postoperative complications, seroma and pain at 30 days and one-year after surgery. METHODS Patients with midline ventral hernia of 4-10 cm in width were included. Computed tomography scan was performed before, 1 and 12 months after surgery. Pain was evaluated using the visual analogue scale. RESULTS Forty-five and forty-seven consecutive patients underwent LIRA and IPOM plus, respectively. Preoperatively, smoke habits and chronic obstructive pulmonary disease rates were statistically significantly higher in the LIRA group (p = 0.0001 and p = 0.012, respectively). Two bulgings (4.4%) occurred in the LIRA group, while in the IPOM plus group occurred 10 bulgings (21.3%) and three recurrences (6.4%) (p = 0.017 and p = 0.085, respectively). Postoperatively, seven (15.6%, Clavien-Dindo I) and four complications (8.5%, two Clavien-Dindo I, two Clavien-Dindo III-b) occurred in the LIRA and in the IPOM plus group, respectively (p = 0.298). One month after surgery, clinical seroma, occurred in five (11.1%) and eight patients (17%) in the LIRA and in the IPOM plus group, respectively (p = 0.416). During follow-up, pain reduction occurred, without statistically significant differences. CONCLUSIONS In this study, even if we analysed a small series, LIRA showed lower bulging and recurrence rates in comparison to IPOM plus at one-year follow-up. Further prospective studies, with a large sample of patients and longer follow-up are required to draw definitive conclusions.
Collapse
Affiliation(s)
- J Gómez-Menchero
- Unit of General and Digestive Surgery, Hospital de Río Tinto, Huelva, Spain
- Unit of General and Digestive Surgery, Hospital Quirónsalud Sagrado Corazón, Seville, Spain
| | - A Balla
- Unit of Innovation in Minimally Invasive Surgery, Department of General and Digestive Surgery, University Hospital "Virgen del Rocio", University of Sevilla, Seville, Spain.
- Coloproctology and Inflammatory Bowel Disease Surgery Unit, IRCCS San Raffaele Scientific Institute, Via Olgettina 60, 20132, Milan, Italy.
| | - J L García Moreno
- Unit of General and Digestive Surgery, Hospital de Río Tinto, Huelva, Spain
| | - A Gila Bohorquez
- Unit of General and Digestive Surgery, Hospital de Río Tinto, Huelva, Spain
| | - J A Bellido-Luque
- Department of General Surgery, University Hospital "Virgen Macarena", Seville, Spain
| | - S Morales-Conde
- Unit of General and Digestive Surgery, Hospital Quirónsalud Sagrado Corazón, Seville, Spain
- Unit of Innovation in Minimally Invasive Surgery, Department of General and Digestive Surgery, University Hospital "Virgen del Rocio", University of Sevilla, Seville, Spain
| |
Collapse
|
5
|
Earnshaw JJ. Publications in BJS and BJS Open by Professor Henrik Kehlet, inaugural winner of the BJS Society Award in Surgery. Br J Surg 2023; 110:1409-1410. [PMID: 37669400 DOI: 10.1093/bjs/znad230] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/07/2023]
|
6
|
Earnshaw JJ. Publications in BJS and BJS Open by Professor Henrik Kehlet, inaugural winner of the BJS Society Award in Surgery. BJS Open 2023; 7:zrad078. [PMID: 37669246 PMCID: PMC10479949 DOI: 10.1093/bjsopen/zrad078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/07/2023] Open
|
7
|
Campanile FC, Podda M, Pecchini F, Inama M, Molfino S, Bonino MA, Ortenzi M, Silecchia G, Agresta F, Cinquini M. Laparoscopic treatment of ventral hernias: the Italian national guidelines. Updates Surg 2023:10.1007/s13304-023-01534-3. [PMID: 37217637 PMCID: PMC10202362 DOI: 10.1007/s13304-023-01534-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2023] [Accepted: 05/10/2023] [Indexed: 05/24/2023]
Abstract
Primary and incisional ventral hernias are significant public health issues for their prevalence, variability of professional practices, and high costs associated with the treatment In 2019, the Board of Directors of the Italian Society for Endoscopic Surgery (SICE) promoted the development of new guidelines on the laparoscopic treatment of ventral hernias, according to the new national regulation. In 2022, the guideline was accepted by the government agency, and it was published, in Italian, on the SNLG website. Here, we report the adopted methodology and the guideline's recommendations, as established in its diffusion policy. This guideline is produced according to the methodology indicated by the SNGL and applying the Grading of Recommendations, Assessment, Development, and Evaluations (GRADE) methodology. Fifteen recommendations were produced as a result of 4 PICO questions. The level of recommendation was conditional for 12 of them and conditional to moderate for one. This guideline's strengths include relying on an extensive systematic review of the literature and applying a rigorous GRADE method. It also has several limitations. The literature on the topic is continuously and rapidly evolving; our results are based on findings that need constant re-appraisal. It is focused only on minimally invasive techniques and cannot consider broader issues (e.g., diagnostics, indication for surgery, pre-habilitation).
Collapse
Affiliation(s)
- Fabio Cesare Campanile
- Division of General Surgery, ASL Viterbo, San Giovanni Decollato-Andosilla Hospital, Civita Castellana, Italy
| | - Mauro Podda
- Department of Surgical Science, University of Cagliari, Cagliari, Italy
| | - Francesca Pecchini
- Department of General Surgery, Emergency and New Technologies, Baggiovara General Hospital, AOU Modena, Modena, Italy
| | - Marco Inama
- General and Mininvasive Surgery Department, Pederzoli Hospital, Peschiera del Garda, Verona, Italy
| | - Sarah Molfino
- General Surgery Unit Chirurgia III, ASST Spedali Civili di Brescia, Brescia, Italy
| | | | - Monica Ortenzi
- Department of General and Emergency Surgery, Marche Polytechnic University, Via Conca 71, 60126, Ancona, Italy.
| | - Gianfranco Silecchia
- Department of Medical-Surgical Sciences and Translation Medicine, Faculty of Medicine and Psychology, Sapienza University of Rome, S. Andrea Hospital, Rome, Italy
| | | | - Michela Cinquini
- Department of Oncology, Laboratory of Methodology of Sistematic Reviews and Guidelines Production, Istituto di Ricerche Farmacologiche Mario Negri IRCCS., Milan, Italy
| |
Collapse
|
8
|
Soliani G, De Troia A, Pesce A, Portinari M, Fabbri N, Leonardi L, Neri S, Carcoforo P, Feo CV. Predictive Factors of Recurrence After Laparoscopic Incisional Hernia Repair: A Retrospective Multicentre Cohort Study. J Laparoendosc Adv Surg Tech A 2023; 33:427-433. [PMID: 36668993 DOI: 10.1089/lap.2022.0465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023] Open
Abstract
Background: The main purpose of this study was to analyze patient-related factors that may influence the risk of hernia recurrence following laparoscopic incisional hernia repair (LIHR), including the potential role of chosen materials. Materials and Methods: A multicenter, retrospective cohort study was conducted on all patients who were aged >18 years and who underwent elective laparoscopic incisional hernia mesh repair at the Departments of Surgery of the S. Anna University Hospital in Ferrara and Sassuolo Hospital in Modena, Italy. Exclusion criteria were as follows: patients undergoing an open or emergency incisional hernia repair or with primary ventral hernia. All hernia and operative variables that may favor hernia recurrence were collected and analyzed. Follow-up was conducted through a standardized telephone interview, followed by an outpatient visit and diagnostic imaging if needed. Results: From September 2002 to September 2017, 312 consecutive patients underwent elective laparoscopic incisional hernia mesh repair. At a mean 22-month follow-up, 273 patients presented no recurrence of incisional hernia and 39 had relapsed. Intra- and postoperative complications were similar between groups. Unadjusted Cox regression analysis showed a statistically significant association between both the partially absorbable mesh (P < .0001) and absorbable tacks (P = .001) and recurrence, while after adjusting for potential confounders, only the partially absorbable mesh was significantly associated with recurrence (P = .007). Conclusions: The laparoscopic approach may be considered safe for incisional hernia mesh repair. In this multicenter, retrospective cohort study, the use of a partially absorbable mesh in LIHR was the only predictor of hernia recurrence. The partially absorbable mesh that was investigated, however, has been withdrawn from the market.
Collapse
Affiliation(s)
- Giorgio Soliani
- Department of Surgery, S. Anna University Hospital and University of Ferrara, Ferrara, Italy
| | - Alessandro De Troia
- Department of Surgery, S. Anna University Hospital and University of Ferrara, Ferrara, Italy
| | - Antonio Pesce
- Department of Surgery, Azienda USL of Ferrara, University of Ferrara, Ferrara, Italy
| | - Mattia Portinari
- Department of Surgery, S. Anna University Hospital and University of Ferrara, Ferrara, Italy
| | - Nicolò Fabbri
- Department of Surgery, Azienda USL of Ferrara, University of Ferrara, Ferrara, Italy
| | - Luca Leonardi
- Unit of General Surgery, Sassuolo Hospital, Azienda USL of Modena, Sassuolo (Modena), Italy
| | - Silvia Neri
- Unit of General Surgery, Sassuolo Hospital, Azienda USL of Modena, Sassuolo (Modena), Italy
| | - Paolo Carcoforo
- Department of Surgery, S. Anna University Hospital and University of Ferrara, Ferrara, Italy
| | - Carlo V Feo
- Department of Surgery, Azienda USL of Ferrara, University of Ferrara, Ferrara, Italy
| |
Collapse
|
9
|
Sebastian L, Alina J, Fabinshy T, Dominik R, Axel S, Jens H, Kilian W, Claudia R, Leonidas K, Julia R, Nadja T, Christian E. AbsorbaTack ™ vs. ProTack ™ vs. sutures: a biomechanical analysis of cervical fixation methods for laparoscopic apical fixations in the porcine model. Arch Gynecol Obstet 2023; 307:863-871. [PMID: 36404354 PMCID: PMC9984508 DOI: 10.1007/s00404-022-06827-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Accepted: 10/16/2022] [Indexed: 11/21/2022]
Abstract
PURPOSE Treatment of pelvic organ prolapse (POP) often requires the use of synthetic mesh. In case of a novel and standardized bilateral apical fixation, both uterosacral ligaments are replaced by polyvinylidene-fluoride (PVDF) tapes. One of the main problems remains the fixation method, which should be stable, but also simple and quick to use. The current study evaluated biomechanical differences between the cervical tape fixation with sutures (group 1), non-absorbable tacks (group 2) and absorbable tacks (group 3) in an in vitro porcine model. METHODS A total of 28 trials, conducted in three groups, were performed on porcine, fresh cadaver uteri. All trials were performed until mesh, tissue or fixation device failure occurred. Primary endpoints were the biomechanical properties maximum load (N), displacement at failure (mm) and stiffness (N/mm). The failure mode was a secondary endpoint. RESULTS There was a significant difference between all three groups concerning the maximum load. Group 1 (sutures) supported a maximum load of 64 ± 15 N, group 2 (non-absorbable tacks) yielded 41 ± 10 N and group 3 (absorbable tacks) achieved 15 ± 8 N. The most common failure mode was a mesh failure for group 1 and 2 and a fixation device failure for group 3. CONCLUSION The PVDF-tape fixation with sutures supports 1.5 times the load that is supported by non-absorbable tacks and 4.2 times the load that is supported by absorbable tacks. Nevertheless, there was also a stable fixation through tacks. Sutures are the significantly stronger and cheaper fixation device but may prolong the surgical time in contrast to the use of tacks.
Collapse
Affiliation(s)
- Ludwig Sebastian
- Department of Gynecology and Obstetrics, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpenerstrasse 34, 50931, Cologne, Germany.
| | - Jansen Alina
- Department of Gynecology and Obstetrics, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpenerstrasse 34, 50931, Cologne, Germany
| | - Thangarajah Fabinshy
- Department of Gynecology and Obstetrics, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpenerstrasse 34, 50931, Cologne, Germany
| | - Ratiu Dominik
- Department of Gynecology and Obstetrics, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpenerstrasse 34, 50931, Cologne, Germany
| | - Sauerwald Axel
- Department of Gynecology and Obstetrics, St. Marien Hospital Düren, Düren, Germany
| | - Hachenberg Jens
- Department of Gynecology and Obstetrics, Hannover Medical School, Hannover, Germany
| | - Wegmann Kilian
- Department for Trauma, Hand and Elbow Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Rudroff Claudia
- Department of General Surgery, Evangelisches Krankenhaus Köln-Weyertal, Cologne, Germany
| | - Karapanos Leonidas
- Department of Urology, Uro-Oncology, Faculty of Medicine and University Hospital Cologne, Robot- Assisted and Reconstructive Surgery, University of Cologne, Cologne, Germany
| | - Radosa Julia
- Department for Gynecology, Obstetrics and Reproductive Medicine, Saarland University Hospital, Homburg, Germany
| | - Trageser Nadja
- Department of Gynecology and Obstetrics, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpenerstrasse 34, 50931, Cologne, Germany
| | - Eichler Christian
- Department of Gynecology and Obstetrics, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpenerstrasse 34, 50931, Cologne, Germany
- Breast Cancer Center, St. Franziskus-Hospital Münster, 48145, Münster, Germany
| |
Collapse
|
10
|
Reoperation for Recurrence is Affected by Type of Mesh in Laparoscopic Ventral Hernia Repair: A Nationwide Cohort Study. Ann Surg 2023; 277:335-342. [PMID: 34520420 DOI: 10.1097/sla.0000000000005206] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To compare the reoperation rate for recurrence between different mesh types in laparoscopic ventral hernia repair. SUMMARY OF BACKGROUND DATA Ventral hernia repair has improved over the last decades. Nevertheless, recurrence rates are still high, and one type of mesh was recently found to increase it even more. METHODS A nationwide cohort study based on prospectively collected data from the Danish Ventral Hernia Database. We included adult patients that had undergone a laparoscopic ventral hernia repair for either an incisional or a primary hernia. The primary and incisional hernias were analyzed in separate cohorts. The mesh-group with the lowest reoperation for recurrence curve was used as the reference. The outcome was reoperation for recurrence. RESULTS Study population comprised 2874 patients with primary hernias and 2726 with incisional hernias. For primary hernias, Physiomesh [HR = 3.45 (2.16-5.51)] and Proceed Surgical Mesh [HR = 2.53 (1.35-4.75)] had a significantly higher risk of reoperation for recurrence than DynaMesh-IPOM. For incisional hernias, Physiomesh [HR = 3.90 (1.80-8.46), Ventralex Hernia Patch (HR = 2.99 (1.13-7.93), Parietex Composite (incl. Optimized) (HR = 2.55 (1.17-5.55), and Proceed Surgical Mesh (HR = 2.63 (1.11-6.20)] all had a significantly higher risk of reoperation for recurrence than Ventralight ST Mesh. CONCLUSION For primary hernias, Physiomesh and Proceed Surgical Mesh had a significantly higher risk of reoperation for recurrence compared with DynaMesh-IPOM. For incisional hernias, the risk was significantly higher for Physiomesh, Parietex Composite, Ventralex Hernia Patch, and Proceed Surgical Mesh compared with Ventralight ST Mesh. This indicates that type of mesh may be associated with outcomes, and mesh choice could therefore depend on hernia type.
Collapse
|
11
|
Gómez-Menchero J, Balla A, Fernández Carazo A, Morales-Conde S. Primary closure of the midline abdominal wall defect during laparoscopic ventral hernia repair: analysis of risk factors for failure and outcomes at 5 years follow-up. Surg Endosc 2022; 36:9064-9071. [PMID: 35729405 DOI: 10.1007/s00464-022-09374-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2022] [Accepted: 05/28/2022] [Indexed: 01/06/2023]
Abstract
BACKGROUND The primary aim of this prospective study is to report bulging and recurrence rates and to analyze the risk factors responsible for failure, after laparoscopic ventral hernia repair (LVHR) with primary closure of defect (PCD) using a running suture and intraperitoneal mesh placement, at 5-year follow-up. The secondary endpoint is to evaluate 30-day postoperative complications, seroma, and pain. METHODS PCD failure was defined as the presence of postoperative bulging and/or recurrence. Pain was evaluated using a visual analogue scale (VAS). After surgery, fifty-eight patients underwent clinical examination and computed tomography scan to diagnose bulging, recurrence, and seroma (classified according to the Morales-Conde classification). RESULTS At 60 months follow-up, recurrence was observed in five patients (8.6%), while bulging, not needing a surgical treatment, occurred in fifteen patients (25.9%). Chronic obstructive pulmonary disease (COPD) is the only risk factor responsible for both outcomes together, bulging and recurrences (p = 0.029), while other considered risk factors as gender, age, body mass index, diabetes, smoke habits, primary or incisional hernia and the ratio defect width/transverse abdominal axis did not achieve the statistically significance. Clinical seroma was diagnosed at one month in eight patients (13.8%). Seromas were observed at one year of follow-up. During the follow-up, pain reduction occurred. CONCLUSION LVHR has evolved toward more anatomical concepts, with the current trend being the abdominal wall anatomical reconstruction to improve its functionality, reducing seroma rates. Based on results obtained, PCD is a reliable technique with excellent recurrence rate at 5 years follow-up, even when the defect closure may generate tension at the midline. On the other hand, this tension could be related with high bulging rate at long-term, particular in case of patients with COPD.
Collapse
Affiliation(s)
- Julio Gómez-Menchero
- Unit of General and Digestive Surgery, Hospital de Río Tinto, Huelva, Spain
- Unit of General and Digestive Surgery, Hospital Quirónsalud Sagrado Corazón, Seville, Spain
| | - Andrea Balla
- Unit of Innovation in Minimally Invasive Surgery, Department of General and Digestive Surgery, University Hospital "Virgen del Rocio", University of Sevilla, Seville, Spain.
| | - Ana Fernández Carazo
- Department of Economics, Quantitative Methods and Economic History, Pablo de Olavide University, Seville, Spain
| | - Salvador Morales-Conde
- Unit of General and Digestive Surgery, Hospital Quirónsalud Sagrado Corazón, Seville, Spain
- Unit of Innovation in Minimally Invasive Surgery, Department of General and Digestive Surgery, University Hospital "Virgen del Rocio", University of Sevilla, Seville, Spain
| |
Collapse
|
12
|
Predictive factors of recurrence for laparoscopic repair of primary and incisional ventral hernias with single mesh from a multicenter study. Sci Rep 2022; 12:4215. [PMID: 35273288 PMCID: PMC8913731 DOI: 10.1038/s41598-022-08024-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Accepted: 01/25/2022] [Indexed: 11/17/2022] Open
Abstract
Laparoscopic ventral hernia repair (LVHR) is a widely practiced treatment for primary (PH) and incisional (IH) hernias, with acceptable outcomes. Prevention of recurrence is crucial and still highly debated. Purpose of this study was to evaluate predictive factors of recurrence following LVHR with intraperitoneal onlay mesh with a single type of mesh for both PH and IH. A retrospective, multicentre study of data collected from patients who underwent LVHR for PH and IH with an intraperitoneal monofilament polypropylene mesh from January 2014 to December 2018 at 8 referral centers was conducted, and statistical analysis for risk factors of recurrence and post-operative outcomes was performed. A total of 1018 patients were collected, with 665 cases of IH (65.3%) and 353 of PH (34.7%). IH patients were older (p < 0.001), less frequently obese (p = 0.031), at higher ASA class (p < 0.001) and presented more frequently with large, swiss cheese type and border site defects (p < 0.001), compared to PH patients. Operative time and hospital stay were longer for IH (p < 0.001), but intraoperative and early post-operative complications and reinterventions were comparable. IH group presented at major risk of recurrence than PH (6.7% vs 0.9%, p < 0.001) and application of absorbable tacks resulted a significative predictive factor for recurrence increasing the risk by 2.94 (95% CI 1.18–7.31). LVHR with a light-weight polypropylene mesh has low intra- and post-operative complications and is appropriate for both IH and PH. Non absorbable tacks and mixed fixation system seem to be preferable to absorbable tacks alone.
Collapse
|
13
|
Novik B, Sandblom G, Ansorge C, Thorell A. Association of Mesh and Fixation Options with Reoperation Risk after Laparoscopic Groin Hernia Surgery: A Swedish Hernia Registry Study of 25,190 Totally Extraperitoneal and Transabdominal Preperitoneal Repairs. J Am Coll Surg 2022; 234:311-325. [PMID: 35213495 PMCID: PMC8834140 DOI: 10.1097/xcs.0000000000000060] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2021] [Revised: 11/02/2021] [Accepted: 11/03/2021] [Indexed: 11/09/2022]
Abstract
BACKGROUND International guidelines concerning mesh and mesh fixation options in laparoscopic totally extraperitoneal (TEP) and transabdominal preperitoneal (TAPP) groin hernia repair are based on studies focusing on either mesh or fixation. We hypothesized that the value of such recommendations is limited by lacking knowledge on how mesh and fixation interact. The current registry-based nationwide cohort study compared different mesh/fixation combinations for relative risks for reoperation after TEP and TAPP groin hernia repair. STUDY DESIGN All TEP and TAPP registered in the Swedish Hernia Registry 2005 to 2017 with standard polypropylene (StdPPM) or lightweight (LWM) flat mesh, having tack, fibrin glue, or no fixation, were included. The endpoint was reoperation due to recurrence as of December 31, 2018. Multivariable Cox regression rendered relative risk differences between the exposures, expressed as hazard ratios (HR) with 95% CIs. RESULTS Of 25,190 repairs, 924 (3.7%) were later reoperated for recurrence. The lowest, mutually equivalent, reoperation risks were associated with StdPPM without fixation (HR 1), StdPPM with metal tacks (HR 0.8, CI 0.4 to 1.4), StdPPM with fibrin glue (HR 1.1, CI 0.7 to 1.6), and LWM with fibrin glue (HR 1.2, CI 0.97 to 1.6). Except for with fibrin glue, LWM correlated with increased risk, whether affixed with metal (HR 1.7, CI 1.1 to 2.7), or absorbable tacks (HR 2.4, CI 1.8 to 3.1), or deployed without fixation (HR 2.0, CI 1.6 to 2.6). CONCLUSIONS With StdPPM, neither mechanical nor glue fixation seemed to improve outcomes. Thus, for this mesh category, we recommend nonfixation. With LWM, we recommend fibrin glue fixation, which was the only LWM alternative on par with nonaffixed StdPPM.
Collapse
Affiliation(s)
- Bengt Novik
- From the Department of Clinical Sciences, Danderyd Hospital (Novik, Thorell), Karolinska Institutet, Stockholm, Sweden
- the Centre for Clinical Research Sörmland, Uppsala University, Eskilstuna, Sweden (Novik)
- the Swedish Hernia Registry Steering Committee, Sweden (Novik, Sandblom)
| | - Gabriel Sandblom
- the Department of Clinical Science and Education, South Hospital (Sandblom), Karolinska Institutet, Stockholm, Sweden
- the Swedish Hernia Registry Steering Committee, Sweden (Novik, Sandblom)
| | - Christoph Ansorge
- the Department of Clinical Science, Interventions and Technology (Ansorge), Karolinska Institutet, Stockholm, Sweden
| | - Anders Thorell
- From the Department of Clinical Sciences, Danderyd Hospital (Novik, Thorell), Karolinska Institutet, Stockholm, Sweden
| |
Collapse
|
14
|
Strategies for Mesh Fixation in Abdominal Wall Reconstruction: Concepts and Techniques. Plast Reconstr Surg 2021; 147:484-491. [PMID: 33235048 DOI: 10.1097/prs.0000000000007584] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
SUMMARY Ventral hernias have numerous causes, ranging from sequelae of surgical procedures to congenital deformities. Patients suffering from these hernias experience a reduced quality of life through pain, associated complications, and physical disfigurement. Therefore, it is important to provide these patients with a steadfast repair that restores functionality and native anatomy. To do this, techniques and materials for abdominal wall reconstruction have advanced throughout the decades, leading to durable surgical repairs. At the cornerstone of this lies the use of mesh. When providing abdominal wall reconstruction, a surgeon must make many decisions with regard to mesh use. Along with the type of mesh and plane of placement of mesh, a surgeon must decide on the method of mesh fixation. Fixation of mesh provides an equal distribution of tension and a more robust tissue-mesh interface, which promotes integration. There exist numerous modalities for mesh fixation, each with its own benefits and drawbacks. This Special Topic article aims to compare and contrast methods of mesh fixation in terms of strength of fixation, clinical outcomes, and cost-effectiveness. Methods included in this review are suture, tack, fibrin glue, mesh strip, and self-adhering modes of fixation.
Collapse
|
15
|
Christophersen C, Fonnes S, Baker JJ, Andresen K, Rosenberg J. Surgeon Volume and Risk of Reoperation after Laparoscopic Primary Ventral Hernia Repair: A Nationwide Register-Based Study. J Am Coll Surg 2021; 233:346-356.e4. [PMID: 34111532 DOI: 10.1016/j.jamcollsurg.2021.05.023] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Revised: 05/14/2021] [Accepted: 05/14/2021] [Indexed: 10/21/2022]
Abstract
BACKGROUND Repairs of primary ventral hernias are common procedures but are associated with high recurrence rates. Therefore, it is important to investigate risk factors for recurrence to optimize current treatments. The aim of this study was to assess the impact of annual surgeon volume on the risk of reoperation for recurrence after primary ventral hernia repair. STUDY DESIGN We conducted a nationwide register-based study with data from the Danish Ventral Hernia Database and the Danish Patient Safety Authority's Online Register linked via surgeons' authorization identification. We included patients 18 years and older, undergoing umbilical or epigastric hernia repair between 2011 and 2020. Annual surgeon volume was categorized into ≤ 9, 10 to 19, 20 to 29, and ≥ 30 cases. Patients were followed until reoperation, death, emigration, or end of the study period. RESULTS We included 7,868 patients who underwent laparoscopic (n = 1,529 [19%]), open mesh (n = 4,138 [53%]), or open nonmesh (n = 2,201 [28%]) repair. There was an increased risk of reoperation after laparoscopic umbilical or epigastric hernia repair for surgeons with ≤ 9 (hazard ratio 6.57; p = 0.008), 10 to 19 (hazard ratio 6.58; p = 0.011), and 20 to 29 (hazard ratio 13.59; p = 0.001) compared with ≥ 30 cases/y. There were no differences in risk of reoperation after open mesh and open nonmesh repair in relation to annual surgeon volume. CONCLUSIONS There was a significantly higher risk of reoperation after laparoscopic primary ventral hernia repair performed by lower-volume surgeons compared with high-volume surgeons. Additional research investigating how sufficient surgical training and supervision are ensured is indicated to reduce risk of reoperation after primary ventral hernia repair.
Collapse
Affiliation(s)
- Camilla Christophersen
- Center for Perioperative Optimization, Department of Surgery, Herlev Hospital, University of Copenhagen, Herlev, Denmark.
| | - Siv Fonnes
- Center for Perioperative Optimization, Department of Surgery, Herlev Hospital, University of Copenhagen, Herlev, Denmark
| | - Jason Joe Baker
- Center for Perioperative Optimization, Department of Surgery, Herlev Hospital, University of Copenhagen, Herlev, Denmark
| | - Kristoffer Andresen
- Center for Perioperative Optimization, Department of Surgery, Herlev Hospital, University of Copenhagen, Herlev, Denmark
| | - Jacob Rosenberg
- Center for Perioperative Optimization, Department of Surgery, Herlev Hospital, University of Copenhagen, Herlev, Denmark
| |
Collapse
|
16
|
Mathes T, Prediger B, Walgenbach M, Siegel R. Mesh fixation techniques in primary ventral or incisional hernia repair. Cochrane Database Syst Rev 2021; 5:CD011563. [PMID: 34046884 PMCID: PMC8160478 DOI: 10.1002/14651858.cd011563.pub2] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
BACKGROUND The use of a mesh in primary ventral or incisional hernia repair lowers the recurrence rate and is the accepted standard of care for larger defects. In laparoscopic primary ventral or incisional hernia repair the insertion of a mesh is indispensable. Different mesh fixation techniques have been used and refined over the years. The type of fixation technique is claimed to have a major impact on recurrence rates, chronic pain, health-related quality of life (HRQOL) and complication rates. OBJECTIVES To determine the impact of different mesh fixation techniques for primary and incisional ventral hernia repair on hernia recurrence, chronic pain, HRQOL and complications. SEARCH METHODS On 2 October 2020 we searched CENTRAL, MEDLINE (Ovid MEDLINE(R)) Epub Ahead of Print, In-Process & Other Non-Indexed Citations, Ovid MEDLINE(R) Daily and Ovid MEDLINE(R)), Ovid Embase, and two trials registries. We also performed handsearches, and contacted experts from the European Hernia Society (EHS). SELECTION CRITERIA We included randomised controlled trials (RCTs) including adults with primary ventral or incisional hernia that compared different types of mesh fixation techniques (absorbable/nonabsorbable sutures, absorbable/nonabsorbable tacks, fibrin glue, and combinations of these techniques). DATA COLLECTION AND ANALYSIS We extracted data in standardised piloted tables, or if necessary, directly into Review Manager 5. We assessed risks of bias with the Cochrane 'Risk of bias' tool. Two review authors independently selected the publications, and extracted data on results. We calculated risk ratios (RRs) for binary outcomes and mean differences (MDs) for continuous outcomes. For pooling we used an inverse-variance random-effects meta-analysis or the Peto method in the case of rare events. We prepared GRADE 'Summary of findings' tables. For laparoscopic repair we considered absorbable tacks compared to nonabsorbable tacks, and nonabsorbable tacks compared to nonabsorbable sutures as key comparisons. MAIN RESULTS We included 10 trials with a total of 787 participants. The number of randomised participants ranged from 40 to 199 per comparison. Eight studies included participants with both primary and incisional ventral hernia. One study included only participants with umbilical hernia, and another only participants with incisional hernia. Hernia size varied between studies. We judged the risk of bias as moderate to high. Absorbable tacks compared to nonabsorbable tacks Recurrence rates in the groups were similar (RR 0.74, 95% confidence interval (CI) 0.17 to 3.22; 2 studies, 101 participants). It is uncertain whether there is a difference between absorbable tacks and nonabsorbable tacks in recurrence because the certainty of evidence was very low. Evidence suggests that the difference between groups in early postoperative, late follow-up, chronic pain and HRQOL is negligible. Nonabsorbable tacks compared to nonabsorbable sutures At six months there was one recurrence in each group (RR 1.00, 95% CI 0.07 to 14.79; 1 study, 36 participants). It is uncertain whether there is a difference between nonabsorbable tacks and nonabsorbable sutures in recurrence because the certainty of evidence was very low. Evidence suggests that the difference between groups in early postoperative, late follow-up and chronic pain is negligible. We found no study that assessed HRQOL. Absorbable tacks compared to absorbable sutures No recurrence was observed at one year (very low certainty of evidence). Early postoperative pain was higher in the tacks group (VAS 0 - 10: MD -2.70, 95% CI -6.67 to 1.27; 1 study, 48 participants). It is uncertain whether there is a difference between absorbable tacks compared to absorbable sutures in early postoperative pain because the certainty of evidence was very low. The MD for late follow-up pain was -0.30 (95% CI -0.74 to 0.14; 1 study, 48 participants). We found no study that assessed HRQOL. Combination of different fixation types (tacks and sutures) or materials (absorbable and nonabsorbable) There were mostly negligible or only small differences between combinations (e.g. tacks plus sutures) compared to a single technique (e.g. sutures only), as well as combinations compared to other combinations (e.g. absorbable sutures combined with nonabsorbable sutures compared to absorbable tacks combined with nonabsorbable tacks) in all outcomes. It is uncertain whether there is an advantage for combining different fixation types or materials for recurrence, chronic pain, HRQOL and complications, because the evidence certainty was very low or low, or we found no study on important outcomes. Nonabsorbable tacks compared to fibrin sealant The two studies showed different directions of effects: one showed higher rates for nonabsorbable tacks, and the other showed higher rates for fibrin sealant. Low-certainty evidence suggests that the difference between groups in early postoperative, late follow-up, chronic pain and HRQOL is negligible. Absorbable tacks compared to fibrin sealant One recurrence in the tacks group and none in the fibrin sealant group were noted after one year (low certainty of evidence). Early postoperative pain might be slightly lower using tacks (VAS 0 - 100; MD -12.40, 95% CI -27.60 to, 2.80;1 study, 50 participants; low-certainty evidence). The pattern of pain and HRQOL course over time (up to 1 year) was similar in the groups (low certainty of evidence). AUTHORS' CONCLUSIONS Currently none of the techniques can be considered superior to any other, because the certainty of evidence was low or very low for all outcomes.
Collapse
Affiliation(s)
- Tim Mathes
- Institute for Research in Operative Medicine (IFOM) - Department for Evidence-based Health Services Research, Witten/Herdecke University, Cologne, Germany
| | - Barbara Prediger
- Institute for Research in Operative Medicine (IFOM) - Department for Evidence-based Health Services Research, Witten/Herdecke University, Cologne, Germany
| | - Maren Walgenbach
- Institute for Research in Operative Medicine (IFOM) - Department for Evidence-based Health Services Research, Witten/Herdecke University, Cologne, Germany
| | - Robert Siegel
- Department of General, Visceral and Cancer Surgery, HELIOS Klinikum Berlin-Buch, Berlin-Buch, Germany
- Faculty of Health, Witten/Herdecke University, Witten, Germany
| |
Collapse
|
17
|
Kohler A, Lavanchy JL, Gasser R, Wyss R, Nowak L, Scheiwiller A, Hämmerli P, Candinas D, Beldi G. Mesh fixation to fascia during incisional hernia repair results in increased prevalence of pain at long-term follow up: a multicenter propensity score matched prospective observational study. Surg Endosc 2021; 36:951-958. [PMID: 33620567 PMCID: PMC8758635 DOI: 10.1007/s00464-021-08355-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2020] [Accepted: 02/03/2021] [Indexed: 10/29/2022]
Abstract
BACKGROUND Patient-reported outcomes such as postoperative pain are critical for the evaluation of outcomes after incisional hernia repair. The aim of this study is to determine the long-term impact of mesh fixation on postoperative pain in patients operated by open and laparoscopic technique. METHODS A multicenter prospective observational cohort study was conducted from September 2011 until March 2016 in nine hospitals across Switzerland. Patients undergoing elective incisional hernia repair were included in this study and stratified by either laparoscopic or open surgical technique. Propensity score matching was applied to balance the differences in baseline characteristics between the treatment groups. Clinical follow-up was conducted 3, 12 and 36 months postoperatively to detect hernia recurrence, postoperative pain and complications. RESULTS Three-hundred-sixty-one patients were included into the study. No significant differences in hernia recurrence and pain at 3, 12 and 36 months postoperatively were observed when comparing the laparoscopic with the open treatment group. Mesh fixation by sutures to fascia versus other mesh fixation led to significantly more pain at 36 months postoperatively (32.8% vs 15.7%, p = 0.025). CONCLUSIONS At long-term follow-up, no difference in pain was identified between open and laparoscopic incisional hernia repair. Mesh fixation by sutures to fascia was identified to be associated with increased pain 36 months after surgery. Omitting mesh fixation by sutures to the fascia may reduce long-term postoperative pain after hernia repair.
Collapse
Affiliation(s)
- Andreas Kohler
- Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Joël L Lavanchy
- Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Rahel Gasser
- Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Roland Wyss
- Department of Visceral and Thoracic Surgery, Kantonsspital Winterthur, Winterthur, Switzerland
| | - Lars Nowak
- Department of Surgery, Spital Grabs, Grabs, Switzerland
| | - Andreas Scheiwiller
- Department of General and Visceral Surgery, Kantonsspital Luzern, Luzern, Switzerland
| | - Peter Hämmerli
- Department of Surgery, Spital Walenstadt, Walenstadt, Switzerland
| | - Daniel Candinas
- Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Guido Beldi
- Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
| |
Collapse
|
18
|
van Silfhout L, Leenders LAM, Heisterkamp J, Ibelings MS. Recurrent incisional hernia repair: surgical outcomes in correlation with body-mass index. Hernia 2020; 25:77-83. [PMID: 33200326 DOI: 10.1007/s10029-020-02320-5] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2020] [Accepted: 10/07/2020] [Indexed: 11/28/2022]
Abstract
BACKGROUND Hernia recurrence rates after incisional hernia repair vary between 8.7 and 32%, depending on multiple factors such as patient characteristics, the use of meshes, surgical technique and the degree of experience of the treating surgeon. Recurrent hernias are considered complex wall hernias, and 20% of all incisional hernia repairs involve a recurrent hernia. The aim of this study was to investigate the outcomes after recurrent incisional hernia repair, in association with surgical technique and body-mass index (BMI). METHODS All patients who had incisional hernia repair between 2013 and 2018 were included. Primary outcome was rate of recurrent incisional hernia after initial hernia repair. Secondary outcomes were complication rate and recurrence rate in association with BMI. RESULTS A number of 269 patients were included, of which 75 patients (27.9%) with a recurrent incisional hernia. Recurrent hernia repair was performed in 49 patients, 83.7% underwent open repair. Complication rate for recurrent hernia repair was higher than for the initial incisional hernia repair. Of the 49 patients with recurrent hernia repair, patients with a BMI above 30 had higher complication and recurrence rates compared to patients with BMI below 30. Especially infectious complications were more common in patients with a higher BMI: 23.1% vs. 0% wound infections. CONCLUSION The results from this study show that complication and recurrence rates are increased after recurrent incisional hernia repair, which are further increased by obesity. Only a limited amount of literature is available on this topic, further larger multicenter studies are necessary, until then a patient-specific surgical approach based on the surgeon's expertise is recommended.
Collapse
Affiliation(s)
| | | | - J Heisterkamp
- Department of Surgery, ETZ, Tilburg, The Netherlands
| | - M S Ibelings
- Department of Surgery, ETZ, Tilburg, The Netherlands
| | | |
Collapse
|
19
|
Helgstrand F, Thygesen LC, Bisgaard T, Jørgensen LN, Friis-Andersen H. Differential recurrence after laparoscopic incisional hernia repair: importance of a nationwide registry-based mesh surveillance. Br J Surg 2020; 107:1130-1136. [PMID: 32239495 DOI: 10.1002/bjs.11562] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2019] [Revised: 12/26/2019] [Accepted: 01/28/2020] [Indexed: 01/28/2023]
Abstract
BACKGROUND Identification of suboptimal mesh products is essential to improve the outcome after hernia surgery. This study investigated whether a national clinical database combined with administrative registries may serve as a tool for postmarketing evaluation of mesh products for hernia surgery. METHODS This was a propensity score-matched case-control cohort study comparing outcomes in patients undergoing laparoscopic incisional hernia repair with either one particular mesh or any other synthetic mesh. Data on patients registered in the Danish Ventral Hernia Database between 2010 and 2016 were combined with administrative data from the Danish National Patient Registry. The primary outcome was operation for recurrence. Secondary outcomes were 30-day readmission, 30-day reoperation for complications (excluding hernia recurrence), and mortality after 30 and 90 days. RESULTS In total, 740 patients who underwent repair with one particular mesh were matched with 1479 patients who received any other synthetic mesh. The rate of repair for hernia recurrence was significantly higher in the particular mesh group than in the reference group: 12·8 versus 6·3 per cent respectively (hazard ratio 2·09, 95 per cent c.i. 1·57 to 2·79; P < 0·001). Use of the particular mesh increased the risk of readmission (odds ratio (OR) 1·53, 1·16 to 2·01; P = 0·002) and reoperation for a complication (OR 1·60, 1·03 to 2·47, P = 0·030). No difference in mortality was found. CONCLUSION Clinical registries with prospectively collected data can provide long-term surveillance of commercial mesh. Laparoscopic incisional hernia repair with one particular mesh was associated with an increased rate of short-term complications and double the risk of repair for recurrence.
Collapse
Affiliation(s)
- F Helgstrand
- Centre of Surgical Science, Department of Surgery, Zealand University Hospital, Koege
| | - L C Thygesen
- National Institute of Public Health, University of Southern Denmark
| | - T Bisgaard
- Department of Surgery, Hvidovre Hospital, University of Copenhagen
| | - L N Jørgensen
- Digestive Disease Centre, Bispebjerg Hospital, University of Copenhagen, Copenhagen
| | - H Friis-Andersen
- Department of Surgery, Horsens Regional Hospital, University of Aarhus, Aarhus, Denmark
| |
Collapse
|
20
|
Sandø A, Rosen MJ, Heniford BT, Bisgaard T. Long-term patient-reported outcomes and quality of the evidence in ventral hernia mesh repair: a systematic review. Hernia 2020; 24:695-705. [DOI: 10.1007/s10029-020-02154-1] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2019] [Accepted: 02/19/2020] [Indexed: 12/30/2022]
|
21
|
Prakash PS, Wijerathne S, Salgaonkar HP, Lomanto D. The efficacy of absorbable versus non-absorbable fixation in laparoscopic totally extraperitoneal (tep) repair of large inguinal hernias. Asian J Surg 2019; 42:995-1000. [DOI: 10.1016/j.asjsur.2019.01.010] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2018] [Revised: 12/24/2018] [Accepted: 01/24/2019] [Indexed: 01/29/2023] Open
|
22
|
Abstract
Objective: To assess the role of registries in the postmarketing surveillance of surgical meshes. Background: To date, surgical meshes are classified as group II medical devices. Class II devices do not require premarket clearance by clinical studies. Ethicon initiated a voluntary market withdrawal of Physiomesh for laparoscopic use after an analysis of unpublished data from the 2 large independent hernia registries—Herniamed German Registry and Danish Hernia Database. This paper now presents the relevant data from the Herniamed Registry. Methods: The present analysis compares the prospective perioperative and 1-year follow-up data collected for all patients with incisional hernia who had undergone elective laparoscopic intraperitoneal onlay mesh repair either with Physiomesh (n = 1380) or with other meshes recommended in the guidelines (n = 3834). Results: Patients with Physiomesh repair had a markedly higher recurrence rate compared with the other recommended meshes (12.0% vs 5.0%; P < 0.001). In the multivariable analysis, the recurrence rate was highly significantly influenced by the mesh type used (P < 0.001). If Physiomesh was used, that led to a highly significant increase in the recurrence rate on 1-year follow-up (odds ratio 2.570, 95% CI 2.057, 3.210). The mesh type used also had a significant influence on chronic pain rates. Conclusions: The importance of real-world data for postmarketing surveillance of surgical meshes has been demonstrated in this registry-based study. Randomized controlled trials are needed for premarket approval of new devices. The role of sponsorship of device studies by the manufacturing company must be taken into account.
Collapse
|
23
|
Abstract
Introduction: Recurrent incisional hernias with a rate of around 20% account for a relatively large proportion of all incisional hernias. It is difficult to issue any binding recommendations on optimum treatment in view of the relatively few studies available on this topic. This review now aims to collate the data available on recurrent incisional hernia. Material and Methods: A systematic search of the available literature was performed in January 2019 using Medline, PubMed, Scopus, Embase, Springer Link, and the Cochrane Library, as well as a search of relevant journals and reference lists. For the present analysis, 47 publications were identified as relevant. Results: There are mainly case series available on the treatment of recurrent incisional hernia. Eight evaluable case series and two prospective comparative studies report on treatment of between 27 and 85 recurrent hernias. After primary open repair of incisional hernia and defect sizes of < 8-10 cm, the recurrence operation can be performed in laparoscopic technique provided the surgeon has sufficient experience in that procedure. That also applies to multiple recurrences after exclusively open repair. There are no evaluable data on a repeat laparoscopic approach after minimally invasive repair of primary incisional hernia. Such an approach should only be chosen by very experienced laparoscopic surgeons and based on a well-founded indication. Further data are urgently needed on treatment of recurrent incisional hernia. Conclusion: Very little data are available on the treatment of recurrent incisional hernia. Based on the tailored approach concept, a laparoscopic approach undertaken by an experienced laparoscopic surgeon can be recommended for recurrent hernias after primary open repair and for defects of up to 8-10 cm.
Collapse
Affiliation(s)
- Ferdinand Köckerling
- Department of Surgery and Center for Minimally Invasive Surgery, Academic Teaching Hospital of Charité Medical School, Vivantes Hospital, Berlin, Germany
| |
Collapse
|
24
|
De Marchi J, Sferle FR, Hehir D. Laparoscopic ventral hernia repair with intraperitoneal onlay mesh-results from a general surgical unit. Ir J Med Sci 2019; 188:1357-1362. [PMID: 30945113 DOI: 10.1007/s11845-019-02012-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2019] [Accepted: 03/21/2019] [Indexed: 12/14/2022]
Abstract
BACKGROUND Symptomatic ventral herniation is a common clinical presentation. The treatment, whether elective or as an emergency, can be difficult and a variety of surgical repairs are utilised. Intraperitoneal onlay mesh (IPOM) involves the placement of a reinforcing prosthesis, usually supported by primary closure of the defect. Intra-abdominal adhesions have been highlighted as a potential complication in utilising this form of mesh placement. Several methods of laparoscopic mesh placement outside of the peritoneal cavity are gaining prominence as potential alternatives to IPOM. AIMS This study reviews our experience with IPOM in the repair of ventral hernia by a single surgical team. METHODS A prospectively maintained electronic database of all laparoscopic ventral hernia repair (LVHR) performed within the study period was analysed and reported. Follow-up questionnaires were sent to patients to follow long-term outcomes. RESULTS One hundred eight patients underwent LVHR over a 7-year period. Demographics demonstrated an obese patient group (BMI 30.89 ± 4.9 kg/m2), with a variety of hernia sizes and morphologies. Hernia recurrence was found in two patients (1.8%). Twenty-nine (26.8%) patients suffered a complication, but only eight (7.4%) of those required intervention beyond pharmacotherapy. Two patients required mesh explantation. CONCLUSIONS IPOM for the general surgeon is a relatively safe and effective method of repairing ventral hernias, with a low recurrence rate.
Collapse
Affiliation(s)
- Joshua De Marchi
- Department of Surgery, Midlands Regional Hospital, Tullamore, Republic of Ireland.
| | - Florin Remus Sferle
- Department of Surgery, Midlands Regional Hospital, Tullamore, Republic of Ireland
| | - Dermot Hehir
- Department of Surgery, Midlands Regional Hospital, Tullamore, Republic of Ireland
| |
Collapse
|
25
|
Zanella S, Lauro E, Franceschi F, Buccelletti F, Potenza A, Zanoni A, Scudo G, Bonadies E, De Bellis M, Ricci F, Vassiliadis A. Laparoscopic Incisional and Ventral Hernia Repair with Absorbable Tacks in a Long Term Follow-up: A Retrospective Control Study. Rev Recent Clin Trials 2019; 14:141-146. [PMID: 30706791 DOI: 10.2174/1574887114666190201111332] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2018] [Revised: 01/22/2019] [Accepted: 01/24/2019] [Indexed: 11/22/2022]
Abstract
BACKGROUND Laparoscopic Incisional and Ventral Hernia Repair (LIVHR) is a safe and worldwide accepted procedure performed using absorbable tacks. The aim of the study was to evaluate recurrence rate in a long term follow-up and whether the results of laparoscopic IVH repair in the elderly (≥65 years old) are different with respect to results obtained in younger patients. METHODS One hundred and twenty-nine consecutive patients (74 women and 55 men, median age 67 years, range = 30-87 years) with ventral (N = 42, 32.5%) or post incisional (N = 87, 67.5%) hernia were enrolled in the study. Patients were divided into two groups according to their age: group A (N = 55, 42.6%) aged <65 years and group B (N = 74, 57.4%) aged ≥65 years. RESULTS The mean operative time was not significantly different between groups (66.7 ± 37 vs. 74 ± 48.4 min, p = 0.4). To the end of 2016, seven recurrences had occurred (group A = 3, group B = 4, p = 1). Complications occurred in 8 (16%) patients in group A and 21 (28.3%) patients in group B. CONCLUSION In conclusion, our results confirm that the use of absorbable tacks does not increase recurrence frequency and laparoscopic incisional and ventral repair is a safety procedure also in elderly patients.
Collapse
Affiliation(s)
- Simone Zanella
- General Surgery, S. Maria del Carmine Hospital, Rovereto, Italy
| | - Enrico Lauro
- General Surgery, S. Maria del Carmine Hospital, Rovereto, Italy
| | | | | | - Annalisa Potenza
- Institute of Internal Medicine, Catholic University of Rome, Rome, Italy
| | - Andrea Zanoni
- General Surgery, S. Maria del Carmine Hospital, Rovereto, Italy
| | - Giovanni Scudo
- General Surgery, S. Maria del Carmine Hospital, Rovereto, Italy
| | - Enzo Bonadies
- General Surgery, S. Maria del Carmine Hospital, Rovereto, Italy
| | - Mario De Bellis
- General and Hepatobiliary Surgery, Department of Surgery, School of Medicine, University of Verona, Piazzale L. Scuro, 10, 37134, Verona, Italy
| | - Francesco Ricci
- General Surgery, S. Maria del Carmine Hospital, Rovereto, Italy
| | | |
Collapse
|
26
|
|
27
|
Effect of fixation devices on postoperative pain after laparoscopic ventral hernia repair: a randomized clinical trial of permanent tacks, absorbable tacks, and synthetic glue. Langenbecks Arch Surg 2018; 403:529-537. [DOI: 10.1007/s00423-018-1676-z] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2017] [Accepted: 04/16/2018] [Indexed: 10/16/2022]
|
28
|
Adding sutures to tack fixation of mesh does not lower the re-operation rate after laparoscopic ventral hernia repair: a nationwide cohort study. Langenbecks Arch Surg 2018; 403:521-527. [DOI: 10.1007/s00423-018-1681-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2017] [Accepted: 05/10/2018] [Indexed: 02/02/2023]
|
29
|
Decreased re-operation rate for recurrence after defect closure in laparoscopic ventral hernia repair with a permanent tack fixated mesh: a nationwide cohort study. Hernia 2018; 22:577-584. [PMID: 29748724 DOI: 10.1007/s10029-018-1776-2] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2017] [Accepted: 04/28/2018] [Indexed: 01/15/2023]
Abstract
PURPOSE To investigate whether defect closure in laparoscopic ventral hernia repair reduces the re-operation rate for recurrence compared with no defect closure. METHODS Data were extracted from the Danish Ventral Hernia Database. Adults with an elective laparoscopic ventral hernia repair with tacks used as mesh fixation were included, if their first repair was between the 1st of January 2007 and the 1st of January 2017. Patients with defect closure were compared with no defect closure. Re-operation rates are presented as crude rates and cumulated adjusted re-operation rates. Sub-analyses assessed the effect of the suture material used during defect closure and also whether defect closure affected both primary and incisional hernias equally. RESULTS Among patients with absorbable tacks as mesh fixation, 443 received defect closure and 532 did not. For patients with permanent tacks, 393 had defect closure and 442 did not. For patients with permanent tacks as mesh fixation, the crude re-operation rates were 3.6% with defect closure and 7.2% without defect closure (p = 0.02). The adjusted cumulated re-operation rate was significantly reduced with defect closure and permanent tacks (hazard ratio = 0.53, 95% confidence interval = 0.28-0.999, p = 0.05). The sub-analysis suggested that defect closure was only beneficial for incisional hernias, and not primary hernias. We did not find any benefits of defect closure for patients with absorbable tacks as mesh fixation. CONCLUSION This nationwide cohort study showed a reduced risk of re-operation for recurrence if defect closure was performed in addition to permanent tacks as mesh fixation during laparoscopic incisional hernia repair.
Collapse
|
30
|
Khan RMA, Bughio M, Ali B, Hajibandeh S, Hajibandeh S. Absorbable versus non-absorbable tacks for mesh fixation in laparoscopic ventral hernia repair: A systematic review and meta-analysis. Int J Surg 2018; 53:184-192. [PMID: 29578094 DOI: 10.1016/j.ijsu.2018.03.042] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2017] [Revised: 03/13/2018] [Accepted: 03/19/2018] [Indexed: 11/25/2022]
Abstract
OBJECTIVES To investigate the outcomes of absorbable versus non-absorbable tacks in patients undergoing laparoscopic ventral hernia repair. METHODS We performed a systematic review in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement standards. We conducted a search of electronic information sources, including MEDLINE; EMBASE; CINAHL; the Cochrane Central Register of Controlled Trials (CENTRAL); the World Health Organization International Clinical Trials Registry; ClinicalTrials.gov; and ISRCTN Register, and bibliographic reference lists to identify all randomised controlled trials (RCTs) and observational studies investigating outcomes of absorbable versus non-absorbable tacks for mesh fixation in patients undergoing laparoscopic ventral hernia repair. We used the Cochrane risk of bias tool and the Newcastle-Ottawa scale to assess the risk of bias of RCTs and observational studies, respectively. Fixed-effect or random-effects models were applied to calculate pooled outcome data. RESULTS We identified three RCTs and two observational studies enrolling a total of 1149 patients. The included patients were comparable in terms of age [Mean difference (MD) 0.28, 95% confidence intervals (CI) -1.45-2, P = 0.75], male gender (MD 0.81, 95% CI 0.63-1.04, P = 0.10), body mass index (MD -041, 95% CI -1.28-0.46, P = 0.36) and hernia defect size (MD 0.12, 95% CI -0.26-0.49, P = 0.54). The mean and median follow-up period was 30 months and 13 months, respectively There was no difference between the two mesh fixation techniques in terms of recurrence [Risk difference (RD) 0.03, 95% CI -0.04, 0.09, P = 0.47], chronic pain [Odds ratio (OR) 0.91, 95% CI 0.62-1.33, P = 0.64], seroma (OR 0.98, 95% CI 0.37-2.60, P = 0.96), haematoma (RD -0.00, 95% CI -0.04- 0.04, P = 0.99), prolonged ileus (OR 0.99, 95% CI 0.24-4.03, P = 0.99), length of hospital stay (MD 0.10, 95% CI -0.36-0.56, P = 0.68) and port-site hernia (OR 0.98, 95% CI 0.13-7.16, P = 0.98). The operative time was longer in absorbable tack group (MD 7.53, 95% CI 1.49-13.58, P = 0.01). The results remain consistent when randomised trials were analysed separately. CONCLUSIONS We found no difference in clinical outcomes between absorbable and non-absorbable tacks for mesh fixation in patients undergoing laparoscopic ventral hernia repair. The quality of the available evidence is moderate with a possibility of type 2 error. High quality RCTs with adequate statistical power are required to provide more robust basis for definite conclusions. Considering the similarity of both techniques in terms of clinical outcomes, the cost-effectiveness of each technique would be an important outcome determining which technique should be used; this needs to be considered as an outcome of interest in future studies.
Collapse
Affiliation(s)
| | - Mumtaz Bughio
- Department of General Surgery, Cork University Hospital, Ireland
| | - Baqar Ali
- Department of General Surgery, North Manchester General Hospital, Manchester, UK
| | - Shahin Hajibandeh
- Department of General Surgery, Stepping Hill Hospital, Stockport, UK
| | | |
Collapse
|
31
|
Chan YW, Sow Z, Lukic D, Monschein M, Calek E, Pretterklieber M, Hollinsky C. Comparison of mesh fixation devices for laparoscopic ventral hernia repair: an experimental study on human anatomic specimens. Surg Endosc 2018; 32:3158-3163. [PMID: 29340814 DOI: 10.1007/s00464-018-6031-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2017] [Accepted: 01/03/2018] [Indexed: 11/25/2022]
Abstract
BACKGROUND As there is a lack of clarity in terms of the tensile strength of mesh fixation for laparoscopic ventral hernia repair (LVHR), our aim was to investigate the immediate tensile strength of currently available mesh fixation devices on human anatomic specimens. METHODS Sixteen recently deceased body donators (mean body mass index of 24.4 kg/m2) were used to test the immediate tensile strength (Newton) of 11 different LVHR mesh fixation devices. RESULTS Each of the 11 different laparoscopic fixation devices was tested 44 times. Non-articulating tackers provided higher fixation resistance to tensile stress in comparison to articulating tackers (5.1-mm ReliaTack™: 16.9 ± 8.7 N vs. 12.2 ± 5.6 N, p = 0.013; 7-mm ReliaTack™: 19.8 ± 9.4 N vs. 15.0 ± 7.0 N, p = 0.007). Absorbable tacks with a greater length, i.e. ≥6 mm (7-mm ReliaTack™, 6-mm SorbaFix™ and 7.2-mm SecureStrap™) had significantly higher fixation tensile strength than tacks with a shorter length, i.e. < 6 mm (5.1-mm ReliaTack™ and 5.1-mm AbsorbaTack™) (p < 0.001). Furthermore, transfascial sutures (PDS 2-0 sutures 26.3 ± 5.6 N) provided superior fixation tensile strength than 5.1-mm AbsorbaTack™ (13.6 ± 7.3 N) and cyanoacrylate glues such as LiquiBand FIX8™ (3.5 ± 2.4 N) (p < 0.001, respectively). There was a significant deterioration in fixation capacity in obese body donators with a body mass index > 30 kg/m2 (13.8 ± 8.0 vs. 17.9 ± 9.7 N, p = 0.044). CONCLUSIONS Although articulating laparoscopic tackers improve accessibility and facilitate the utilization of tacks within the fixation weak spot adjacent to the trocar placement, an articulating shaft that is not ergonomic to use may limit mechanisms of force transmission. For mesh fixation in LVHR, transfascial sutures and tacks with a longer length provide better immediate fixation tensile strength results.
Collapse
Affiliation(s)
- Yi-Wei Chan
- Department of Surgery, General Hospital Steyr, Sierninger Straße 170, 4400, Steyr, Austria.
| | - Zacaria Sow
- Department of Surgery, SMZ Floridsdorf Hospital Vienna, Vienna, Austria
| | - Dobrica Lukic
- Department of Surgery, SMZ Floridsdorf Hospital Vienna, Vienna, Austria
| | | | | | - Michael Pretterklieber
- Division of Anatomy, Center for Anatomy and Cell Biology, Medical University of Vienna, Vienna, Austria
| | | |
Collapse
|
32
|
Gómez-Menchero J, Guadalajara Jurado JF, Suárez Grau JM, Bellido Luque JA, García Moreno JL, Alarcón Del Agua I, Morales-Conde S. Laparoscopic intracorporeal rectus aponeuroplasty (LIRA technique): a step forward in minimally invasive abdominal wall reconstruction for ventral hernia repair (LVHR). Surg Endosc 2018; 32:3502-3508. [PMID: 29344785 DOI: 10.1007/s00464-018-6070-y] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2017] [Accepted: 01/12/2018] [Indexed: 11/28/2022]
Abstract
BACKGROUND Closing the defect (CD) during laparoscopic ventral hernia repair began to be performed in order to decrease seroma, to improve the functionality of the abdominal wall, and to decrease the bulging effect. However, tension at the incision after CD in large defects is related to an increased rate of pain and recurrence. We present the preliminary results of a new technique for medium midline hernias as an alternative to conventional CD. METHODS A prospective controlled study was conducted from January 2015 to January 2017 to evaluate an elective new procedure (LIRA) performed on patients with midline ventral hernias (4-10 cm width). The posterior rectus aponeurosis was opened lengthwise around the hernia defect using a laparoscopic approach to create two flaps and was then sutured. The size of the flaps was estimated using a mathematical formula. An on-lay mesh was placed intraperitoneal overlapping the fascia defect. The data analyzed included patient demographics, operative parameters, and complications. A computerized tomography was performed preoperatively and postoperatively (1 month and 1 year) to evaluate recurrence, distance between rectus and seroma. RESULTS Twelve patients were included. Mean width of the defect was 5.5 cm. Average VAS (24 h) was 3.9, 1.1 (1 month), and 0 (1 year). Mean preoperative distance between rectus was 5.5 cm; postoperative was 2.2 cm (1 year). Radiological seroma at first month was detected in 50%. Mean follow-up was 15 months. CONCLUSION The LIRA technique could be considered as an alternative to conventional CD or endoscopic component separation for medium defects under 10 cm in width. This technique obtained a "no tension" effect that could be related to a lower rate of postoperative pain with no recurrence or bulging, being a safe, feasible, and reproducible technique.
Collapse
Affiliation(s)
- Julio Gómez-Menchero
- Department of General Surgery, Riotinto General Hospital, Minas de Riotinto, Huelva, Spain. .,, Juan de Zoyas 6, Portal 1, 41018, Seville, Spain.
| | | | | | | | | | - Isaías Alarcón Del Agua
- Unit of Innovation in Minimally Invasive Surgery, University Hospital "Virgen del Rocio", Seville, Spain
| | - Salvador Morales-Conde
- Unit of Innovation in Minimally Invasive Surgery, University Hospital "Virgen del Rocio", Seville, Spain
| |
Collapse
|
33
|
Ermolov AS, Koroshvili VT, Blagovestnov DA. [Postoperative ventral hernia - unsolved issues of surgical tactics]. Khirurgiia (Mosk) 2018:81-86. [PMID: 30531743 DOI: 10.17116/hirurgia201810181] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Currently, there is no unified opinion on some problematic issues of surgical treatment of postoperative ventral hernias. Current approaches and surgical aspects of primary and recurrent postoperative ventral are reviewed in the article.
Collapse
Affiliation(s)
- A S Ermolov
- Russian Medical Academy of Continuing Professional Education, Sklifosovsky Research Institute for Emergency Care, Moscow, Russia
| | - V T Koroshvili
- Russian Medical Academy of Continuing Professional Education, Sklifosovsky Research Institute for Emergency Care, Moscow, Russia
| | - D A Blagovestnov
- Russian Medical Academy of Continuing Professional Education, Sklifosovsky Research Institute for Emergency Care, Moscow, Russia
| |
Collapse
|
34
|
Poupalou A, Vrancken C, Vanderveken E, Steyaert H. Use of Nonabsorbable Spiral Tacks for Mesh Reinforcement in Thoracoscopic Repair of Congenital Diaphragmatic Hernia. European J Pediatr Surg Rep 2018; 6:e27-e31. [PMID: 29577002 PMCID: PMC5864520 DOI: 10.1055/s-0037-1612618] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2016] [Accepted: 11/03/2017] [Indexed: 01/17/2023] Open
Abstract
Thoracoscopic prosthetic repair of congenital diaphragmatic hernia (CDH) is a well-established and safe technique in experienced hands but the patching procedure is technically demanding and time consuming. To address the challenges associated with this process (confined working space and restricted time), the aim of this article is to assess the potential improvements in feasibility, efficacy, and safety of patch fixation by using nonabsorbable helicoidal tacks in neonates and infants for the repair of large CDH by thoracoscopy. The new technique has all the advantages of minimal invasive surgery in very young children combined with the advantages of reduced operating time and increased simplicity, and may be a good option in cases of recurrence.
Collapse
Affiliation(s)
- Anna Poupalou
- Department of Pediatric Surgery/ Pediatrics, Université Libre de Bruxelles (ULB), Hôpital CHU St Pierre, Bruxelles, Belgium
- ChirurgiePédiatrique, Université Libre de Bruxelles (ULB), Hôpital HUDERF, Bruxelles, Belgium
| | - Celine Vrancken
- ChirurgiePédiatrique, Université Libre de Bruxelles (ULB), Hôpital HUDERF, Bruxelles, Belgium
| | - Erwin Vanderveken
- ChirurgiePédiatrique, Université Libre de Bruxelles (ULB), Hôpital HUDERF, Bruxelles, Belgium
| | - Henri Steyaert
- ChirurgiePédiatrique, Université Libre de Bruxelles (ULB), Hôpital HUDERF, Bruxelles, Belgium
| |
Collapse
|
35
|
Baker JJ, Öberg S, Andresen K, Klausen TW, Rosenberg J. Systematic review and network meta-analysis of methods of mesh fixation during laparoscopic ventral hernia repair. Br J Surg 2017; 105:37-47. [PMID: 29227530 DOI: 10.1002/bjs.10720] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2017] [Revised: 06/13/2017] [Accepted: 09/06/2017] [Indexed: 12/25/2022]
Abstract
BACKGROUND Ventral hernia repairs are common and have high recurrence rates. They are usually repaired laparoscopically with an intraperitoneal mesh, which can be fixed in various ways. The aim was to evaluate the recurrence rates for the different fixation techniques. METHODS This systematic review included studies with human adults with a ventral hernia repaired with an intraperitoneal onlay mesh. The outcome was recurrence at least 6 months after operation. Cohort studies with 50 or more participants and all RCTs were included. PubMed, Embase and the Cochrane Library were searched on 22 September 2016. RCTs were assessed with the Cochrane risk-of-bias assessment tool and cohort studies with the Newcastle-Ottawa scale. Studies comparing fixation techniques were included in a network meta-analysis, which allowed comparison of more than two fixation techniques. RESULTS Fifty-one studies with a total of 6553 participants were included. The overall crude recurrence rates with the various fixation techniques were: absorbable tacks, 17·5 per cent (2 treatment groups); absorbable tacks with sutures, 0·7 per cent (3); permanent tacks, 7·7 per cent (20); permanent tacks with sutures, 6·0 per cent (25); and sutures, 1·5 per cent (6). Six studies were included in a network meta-analysis, which favoured fixation with sutures. Although statistical significance was not achieved, there was a 93 per cent chance of sutures being better than one of the other methods. CONCLUSION Both crude recurrence rates and the network meta-analysis favoured fixation with sutures during laparoscopic ventral hernia repair.
Collapse
Affiliation(s)
- J J Baker
- Centre for Perioperative Optimization, Department of Surgery, Herlev Hospital, University of Copenhagen, Herlev, Denmark
| | - S Öberg
- Centre for Perioperative Optimization, Department of Surgery, Herlev Hospital, University of Copenhagen, Herlev, Denmark
| | - K Andresen
- Centre for Perioperative Optimization, Department of Surgery, Herlev Hospital, University of Copenhagen, Herlev, Denmark
| | - T W Klausen
- Clinical Research Unit, Department of Haematology, Herlev Hospital, University of Copenhagen, Herlev, Denmark
| | - J Rosenberg
- Centre for Perioperative Optimization, Department of Surgery, Herlev Hospital, University of Copenhagen, Herlev, Denmark
| |
Collapse
|
36
|
Warren JA, McGrath SP, Hale AL, Ewing JA, Carbonell AM, Cobb WS. Patterns of Recurrence and Mechanisms of Failure after Open Ventral Hernia Repair with Mesh. Am Surg 2017. [DOI: 10.1177/000313481708301131] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Recurrence after ventral hernia repair (VHR) remains a significant complication. We sought to identify the technical aspects of VHR associated with recurrence. Patients who underwent open midline VHR between 2006 and 2013 (n = 261) were retrospectively evaluated. Patients with recurrence (Group 1, n = 48) were compared with those without recurrence (Group 2, n = 213). Smoking, diabetes, and body mass index were not different between groups. More patients in Group 1 underwent clean-contaminated, contaminated, or dirty procedures (43.8 vs 27.7%; P = 0.021). Group 1 had a higher incidence of surgical site occurrence (52.1 vs 32.9%; P = 0.020) and surgical site infection (43.8 vs 15.5%; P < 0.001). Recurrences were due to central mesh failure (CMF) (39.6%), midline recurrence after biologic or bioabsorbable mesh repair (18.8%), superior midline (16.7%), lateral (16.7%), and after mesh explantation (12.5%). Most CMF (78.9%) occurred with light-weight polypropylene (LWPP). Recurrence was higher if the midline fascia was unable to be closed. Recurrence with midweight polypropylene (MWPP) was lower than biologic (P < 0.001), bioabsorbable (P = 0.006), and light-weight polypropylene (P = 0.046) mesh. Fixation, component separation technique, and mesh position were not different between groups. Wound complications are associated with subsequent recurrence, whereas midweight polypropylene is associated with a lower overall risk of recurrence and, specifically, CMF.
Collapse
Affiliation(s)
- Jeremy A. Warren
- Department of Surgery, Division of Minimally Invasive Surgery, Greenville Health System, Greenville, South Carolina
| | - Sean P. McGrath
- Department of Surgery, Division of Minimally Invasive Surgery, Greenville Health System, Greenville, South Carolina
| | - Allyson L. Hale
- Department of Surgery, Division of Minimally Invasive Surgery, Greenville Health System, Greenville, South Carolina
| | - Joseph A. Ewing
- Department of Surgery, Division of Minimally Invasive Surgery, Greenville Health System, Greenville, South Carolina
| | - Alfredo M. Carbonell
- Department of Surgery, Division of Minimally Invasive Surgery, Greenville Health System, Greenville, South Carolina
| | - William S. Cobb
- Department of Surgery, Division of Minimally Invasive Surgery, Greenville Health System, Greenville, South Carolina
| |
Collapse
|
37
|
Harsløf S, Zinther N, Harsløf T, Danielsen C, Wara P, Friis-Andersen H. Polypropelene-mesh properties and type of anchoring do not influence strength of parietal ingrowth. Langenbecks Arch Surg 2017; 402:1047-1054. [DOI: 10.1007/s00423-017-1602-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2017] [Accepted: 07/06/2017] [Indexed: 10/19/2022]
|
38
|
Bridging with reduced overlap: fixation and peritoneal grip can prevent slippage of DIS class A meshes. Hernia 2017; 21:455-467. [DOI: 10.1007/s10029-017-1583-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2016] [Accepted: 01/13/2017] [Indexed: 10/20/2022]
|
39
|
Substantial variation among hernia experts in the decision for treatment of patients with incisional hernia: a descriptive study on agreement. Hernia 2016; 21:271-278. [DOI: 10.1007/s10029-016-1562-y] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2016] [Accepted: 11/25/2016] [Indexed: 12/20/2022]
|
40
|
Helgstrand F, Jorgensen LN. The Danish Ventral Hernia Database - a valuable tool for quality assessment and research. Clin Epidemiol 2016; 8:719-723. [PMID: 27822119 PMCID: PMC5094577 DOI: 10.2147/clep.s99501] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
AIM The Danish Ventral Hernia Database (DVHD) provides national surveillance of current surgical practice and clinical postoperative outcomes. The intention is to reduce postoperative morbidity and hernia recurrence, evaluate new treatment strategies, and facilitate nationwide implementation of evidence-based treatment strategies. This paper describes the design and purpose of DVHD. STUDY POPULATION Adult (≥18 years) patients with a Danish Civil Registration Number and undergoing surgery under elective or emergency conditions for ventral hernia in a Danish surgical department from 2007 and beyond. A total of 80% of all ventral hernia repairs performed in Denmark were reported to the DVHD. MAIN VARIABLES Demographic data (age, sex, and center), detailed hernia description (eg, type, size, surgical priority), and technical aspects (open/laparoscopic and mesh related factors) related to the surgical repair are recorded. Data registration is mandatory. Data may be merged with other Danish health registries and information from patient questionnaires or clinical examinations. DESCRIPTIVE DATA More than 37,000 operations have been registered. Data have demonstrated high agreement with patient files. The data allow technical proposals for surgical improvement with special emphasis on reduced incidences of postoperative complications, hernia recurrence, and chronic pain. CONCLUSION DVHD is a prospective and mandatory registration system for Danish surgeons. It has collected a high number of operations and is an excellent tool for observing changes over time, including adjustment of several confounders. This national database registry has impacted on clinical practice in Denmark and led to a high number of scientific publications in recent years.
Collapse
Affiliation(s)
- Frederik Helgstrand
- Department of Surgery, Køge Hospital, University of Copenhagen, Køge, Denmark
| | | |
Collapse
|
41
|
Postoperative complications as an independent risk factor for recurrence after laparoscopic ventral hernia repair: a prospective study of 417 patients with long-term follow-up. Surg Endosc 2016; 31:1469-1477. [PMID: 27495336 DOI: 10.1007/s00464-016-5140-2] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2016] [Accepted: 07/18/2016] [Indexed: 10/21/2022]
Abstract
BACKGROUND Laparoscopic ventral hernia repair (LVHR) has become widely used. This study evaluates outcomes of LVHR, with particular reference to complications, seromas, and long-term recurrence. METHODS A review of a prospective database of consecutive patients undergoing LVHR with intraperitoneal onlay mesh (IPOM) was performed at a single institution. Patient's characteristics, surgical procedures, and postoperative outcomes were analyzed and related to long-term recurrence. RESULTS From 2005 to 2014, 417 patients underwent LVHR. Mean age and body mass index (BMI) were 54 years and 31 kg/m2. Mesh fixation was carried out with transfascial sutures, completed with absorbable tacks (72 %), metal tacks (24 %), or intraperitoneal sutures (4 %). Intraoperative complications occurred in three patients. Overall morbidity included 8.25 % of minor complications and 2.5 % of major complications without mortality. The overall recurrence rate was 9.8 %. Median time for recurrence was 15.3 months (3-72) and median follow-up was 31.6 months (8-119). In a multivariate analysis, previous interventions (OR 1.44; CI 1.15-1.79; p = 0.01), postoperative complications (OR 2.57; CI 1.09-6.03; p = 0.03), and Clavien-Dindo score >2 (OR 1.43; CI 1.031-1.876; p = 0.02) appeared as independent prognostic factors of recurrence. Minor complications were associated with 14.7 % of recurrence and major complications with 30 % of recurrence. Emergency LVHR (6 %) did not increase the rate of complications. Overall seroma rate was 18.7 %, with 1.4 % of persisting or complicated seroma. BMI (OR 1.05; CI 1.01-1.08; p = 0.026) and vascular surgery history (OR 5.74; CI 2.11-15.58; p < 0.001) were independent predictive factors for seroma. Recurrence did not appear to be related to seroma. CONCLUSION LVHR combines the benefits of laparoscopy with those of mesh repair. Seroma formation should no longer be considered as a complication. It is spontaneously regressive in most cases. Postoperative complications and their degree of severity appear to be independent prognostic factors for recurrence, which can be limited with a standardized technique and may make IPOM-LVHR a reference procedure.
Collapse
|
42
|
Shi Z, Fan X, Zhai S, Zhong X, Huang D. Fibrin glue versus staple for mesh fixation in laparoscopic transabdominal preperitoneal repair of inguinal hernia: a meta-analysis and systematic review. Surg Endosc 2016; 31:527-537. [PMID: 27351657 DOI: 10.1007/s00464-016-5039-y] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2016] [Accepted: 06/11/2016] [Indexed: 10/21/2022]
Abstract
BACKGROUND The aim of this study was to compare outcomes of mesh fixation using fibrin glue versus staple in laparoscopic transabdominal preperitoneal (TAPP) repair of inguinal hernia. METHODS AND PROCEDURES Database searches were carried out in PubMed, Embase, Cochrane Library, Web of Science and Cochrane databases until February 2016 using specific search terms. Studies which compared fibrin glue and staple for mesh fixation in laparoscopic transabdominal preperitoneal repair of inguinal hernia were enrolled. Outcomes, including inguinal hernia recurrence, chronic inguinal pain, seroma or hematoma formation and operating time, were measured. RESULTS Four randomized controlled trials (RCTs, 430 patients) and six non-randomized controlled trials (non-RCTs, 8637 patients) were analyzed. Meta-analysis of the four RCTs showed no significant difference in hernia recurrence (OR 2.10, 95 % CI 0.61, 7.22), seroma or hematoma formation (OR 0.55, 95 % CI 0.27, 1.14) and operating time (SMD 0.80, 95 % CI -0.34, 1.94). Similarly, there was no significant difference in most of the outcomes of the six non-RCTs. CONCLUSIONS Our meta-analysis and systematic review shows that the use of fibrin glue fixation may provide an alternative approach to staple fixation in TAPP inguinal hernia repair without increasing the postoperative morbidity. Large-scale RCTs with long-term follow-up are still needed to further assess postoperative outcomes such as chronic pain and disease recurrence.
Collapse
Affiliation(s)
- Zhaoqi Shi
- Department of General Surgery, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, 3 East Qingchun Rd, Hangzhou, 310016, China
| | - Xiaoxiao Fan
- Department of General Surgery, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, 3 East Qingchun Rd, Hangzhou, 310016, China
| | - Shuting Zhai
- Department of General Surgery, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, 3 East Qingchun Rd, Hangzhou, 310016, China
| | - Xin Zhong
- Department of General Surgery, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, 3 East Qingchun Rd, Hangzhou, 310016, China
| | - Diyu Huang
- Department of General Surgery, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, 3 East Qingchun Rd, Hangzhou, 310016, China.
| |
Collapse
|
43
|
Tobler WD, Itani KMF. Current Status and Challenges of Laparoscopy in Ventral Hernia Repair. J Laparoendosc Adv Surg Tech A 2016; 26:281-9. [PMID: 27027828 DOI: 10.1089/lap.2016.0095] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023] Open
Abstract
Laparoscopic repair of ventral hernias gained strong popularity in the late nineties with some of the early enthusiasm lost later in time. We review the current status and challenges of laparoscopy in ventral hernia repair and best practices in this area. We specifically looked at patient and hernia defect factors, technical considerations that have contributed to the successes, and some of the failures of laparoscopic ventral hernia repair (LVHR). Patients best suited for a laparoscopic repair are those who are obese and diabetic with a total defect size not to exceed 10 cm in width or a "Swiss cheese" defect. Overlap of mesh to healthy fascia of at least 5 cm in every direction, with closure of the defect, is essential to prevent recurrence or bulging over time. Complications specifically related to surgical site occurrence favor the laparoscopic approach. Recurrence rates, satisfaction, and health-related quality of life results are similar to open repairs, but long-term data are lacking. There is still conflicting data regarding ways of fixating the mesh. The science of prosthetic material appropriate for intraperitoneal placement continues to evolve. The field continues to be plagued by single author, single institution, and small nonrandomized observational studies with short-term follow-up. The recent development of large prospective databases might allow for pragmatic and point-of-care studies with long-term follow-up. We conclude that LVHR has evolved since its inception, has overcome many challenges, but still needs better long-term studies to evaluate evolving practices.
Collapse
Affiliation(s)
- William D Tobler
- 1 Department of Plastic Surgery, University of Pittsburgh , Pittsburgh, Pennsylvania
| | - Kamal M F Itani
- 2 VA Boston Healthcare System, Boston University and Harvard Medical School , Boston, Massachusetts
| |
Collapse
|
44
|
The best of two worlds: a new innovative laparoscopic Rives-Stoppa technique for ventral/incisional hernias--"the Brazilian technique": Invited commentary to: Transabdominal midline reconstruction by minimally invasive surgery: technique and results. Costa TN, Abdalla RZ, Santo MA, Tavares RRFM, Abdalla BMZ, Cecconello I. Hernia 2016; 20:267-70. [PMID: 26883981 DOI: 10.1007/s10029-016-1458-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2016] [Accepted: 01/09/2016] [Indexed: 12/18/2022]
|
45
|
Kallinowski F, Baumann E, Harder F, Siassi M, Mahn A, Vollmer M, Morlock MM. Dynamic intermittent strain can rapidly impair ventral hernia repair. J Biomech 2015; 48:4026-4036. [DOI: 10.1016/j.jbiomech.2015.09.045] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2015] [Revised: 09/25/2015] [Accepted: 09/26/2015] [Indexed: 12/29/2022]
|
46
|
Silecchia G, Cavallaro G, Raparelli L, Olmi S, Baldazzi G, Campanile FC. Titanium versus absorbable tacks comparative study (TACS): a multicenter, non-inferiority prospective evaluation during laparoscopic repair of ventral and incisional hernia: study protocol for randomized controlled trial. Trials 2015; 16:249. [PMID: 26037907 PMCID: PMC4460685 DOI: 10.1186/s13063-015-0779-x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2015] [Accepted: 05/22/2015] [Indexed: 12/22/2022] Open
Abstract
BACKGROUND Laparoscopic repair of ventral and incisional hernias has gained popularity since many studies have reported encouraging results in terms of outcomee and recurrence. Choice of mesh and fixation methods are considered crucial issues in preventing recurrences and complications. Lightweight meshes are considered the first choice due to their biomechanical properties and the ability to integrate into the abdominal wall. Titanium helicoidal tacks still represent the "gold standard" for mesh fixation, even if they have been suggested to be involved in the genesis of post-operative pain and complications. Recently, absorbable tacks have been introduced, under the hypothesis that there will be no need to maintain a permanent fixation device after mesh integration. Nevertheless, there is no evidence that absorbable tacks may guarantee the same results as titanium tacks in terms of strength of fixation and recurrence rates. The primary end point of the present trial is to test the hypothesis that absorbable tacks are non-inferior to titanium tacks in laparoscopic incisional and ventral hernia repair (LIVHR) by lightweight polypropylene mesh, in terms of recurrence rates at 3-year follow-up. Surgical complications, post-operative stay, comfort and pain are secondary end points to be assessed. METHODS/DESIGN Two hundred and twenty patients with ventral hernia will be randomized into 2 groups: Group A (110) patients will be submitted to LIVHR by lightweight polypropylene mesh fixed by titanium tacks; Group B (110) patients will be submitted to LIVHR by lightweight polypropylene mesh fixed by absorbable tacks. DISCUSSION A few retrospective studies have reported similar results when comparing absorbable versus non-absorbable tacks in terms of intraoperative and early post-operative outcomes. These studies have the pitfalls to be retrospective evaluation of small series of patients, and the reported results still need to be validated by larger series and prospective studies. The aim of the present trial is to investigate and test the non-inferiority of absorbable versus non-absorbable tacks in terms of hernia recurrence rates, in order to assess whether the use of absorbable tacks may achieve the same results as non-absorbable tacks in mid-term and long-term settings. TRIAL REGISTRATION NUMBER NCT02076984: 5 June 2014 (ClinicalTrials.gov).
Collapse
Affiliation(s)
- Gianfranco Silecchia
- Department of Medico-Surgical Sciences and Biotechnologies, Sapienza University of Rome, Rome, Italy. .,General Surgery Unit, ICOT Hospital, Latina, LT, Italy.
| | - Giuseppe Cavallaro
- Department of Medico-Surgical Sciences and Biotechnologies, Sapienza University of Rome, Rome, Italy. .,General Surgery Unit, ICOT Hospital, Latina, LT, Italy.
| | | | - Stefano Olmi
- General Surgery Unit, Gruppo Ospedaliero San Donato, Milan, Italy.
| | - Gianandrea Baldazzi
- General and Mini-Invasive Surgery Unit, Abano Terme Hospital, Abano Terme, PD, Italy.
| | | |
Collapse
|