1
|
Cardiac CT for Guiding Mitral Valve Interventions. CURRENT CARDIOVASCULAR IMAGING REPORTS 2017. [DOI: 10.1007/s12410-017-9428-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
2
|
Mehra L, Raheja S, Agarwal S, Rani Y, Kaur K, Tuli A. Anatomical considerations of percutaneous transvenous mitral annuloplasty: a novel procedure for treatment of functional mitral regurgitation. Anat Cell Biol 2016; 49:68-72. [PMID: 27051569 PMCID: PMC4819079 DOI: 10.5115/acb.2016.49.1.68] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2015] [Revised: 01/29/2016] [Accepted: 03/03/2016] [Indexed: 12/27/2022] Open
Abstract
Percutaneous transvenous mitral annuloplasty (PTMA) has evolved as a latest procedure for the treatment of functional mitral regurgitation. It reduces mitral valve annulus (MVA) size and increases valve leaflet coaptation via compression of coronary sinus (CS). Anatomical considerations for this procedure were elucidated in the present study. In 40 formalin fixed adult cadaveric human hearts, relation of the venous channel formed by CS and great cardiac vein (GCV) to MVA and the adjacent arteries was described, at 6 points by making longitudinal sections perpendicular to the plane of MVA, numbered 1-6 starting from CS ostium. CS/GCV formed a semicircular venous channel on the atrial side of MVA. Based on the distance of CS/GCV from MVA, two patterns were identified. In 37 hearts, the venous channel at point 2 was widely separated from the MVA compared to the two ends and in three hearts a nonconsistent pattern was observed. GCV crossed circumflex artery superficially. GCV or CS crossed the left marginal artery and ventricular branches of circumflex artery superficially in 17 and 23 hearts, respectively. As the venous channel was related more to the left atrial wall, PTMA devices probably exert an indirect traction on MVA. The arteries crossing deep to the venous channel may be compressed by PTMA device leading to myocardial ischemia. Knowledge of the spatial relations of MVA and a preoperative and postoperative angiogram may help to reduce such complications during PTMA.
Collapse
Affiliation(s)
- Lalit Mehra
- Department of Anatomy, Lady Hardinge Medical College and Associated Hospitals, New Delhi, India
| | - Shashi Raheja
- Department of Anatomy, Lady Hardinge Medical College and Associated Hospitals, New Delhi, India
| | - Sneh Agarwal
- Department of Anatomy, Lady Hardinge Medical College and Associated Hospitals, New Delhi, India
| | - Yashoda Rani
- Department of Forensic Medicine and Toxicology, Lady Hardinge Medical College and Associated Hospitals, New Delhi, India
| | - Kulwinder Kaur
- Department of Anatomy, Lady Hardinge Medical College and Associated Hospitals, New Delhi, India
| | - Anita Tuli
- Department of Anatomy, Lady Hardinge Medical College and Associated Hospitals, New Delhi, India
| |
Collapse
|
3
|
Abstract
Mitral regurgitation is one of the most common forms of heart valve disorder, which may result in heart failure. Due to the rapid ageing of the population, surgical repair and replacement treatments, which have represented an effective treatment in the past, are now unsuitable for about half of symptomatic patients, who are judged high-risk. Encouraged by the positive experience with transcatheter aortic valves and percutaneous reconstructive mitral treatments, a number of research groups are currently engaged in the development of minimally invasive approaches for the functional replacement of the mitral valve. The first experiences have clearly demonstrated that the approach is feasible and promising, though significant progress is still required in the prostheses design and implantation procedures before the treatment can establish as a safe and effective solution. This review analyses the devices currently at a most advanced stage of development, describing their main features and the technical solutions that they adopt in order to respond to the functional requirements of the most challenging of the heart valves.
Collapse
|
4
|
Herrmann TA, Siefert AW, Pressman GS, Gollin HR, Touchton SA, Saikrishnan N, Yoganathan AP. In vitro comparison of Doppler and catheter-measured pressure gradients in 3D models of mitral valve calcification. J Biomech Eng 2014; 135:94502. [PMID: 23720100 DOI: 10.1115/1.4024579] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2012] [Accepted: 05/16/2013] [Indexed: 11/08/2022]
Abstract
Mitral annular calcification (MAC) involves calcium deposition in the fibrous annulus supporting the mitral valve (MV). When calcification extends onto the leaflets, valve opening can be restricted. The influence of MAC MV geometry on Doppler gradients is unknown. This study describes a novel methodology to rapid-prototype subject-specific MAC MVs. Replicated valves were used to assess the effects of distorted annular-leaflet geometry on Doppler-derived, transmitral gradients in comparison to direct pressure measurements and to determine if transmitral gradients vary according to measurement location. Three-dimensional echocardiography data sets were selected for two MAC MVs and one healthy MV. These MVs were segmented and rapid prototyped in their middiastolic configuration for in vitro testing. The effects of MV geometry, measurement modality, and measurement location on transmitral pressure gradient were assessed by Doppler and catheter at three locations along the MV's intercommissural axis. When comparing dimensions of the rapid-prototyped valves to the subject echocardiography data sets, mean relative errors ranged from 6.2% to 35%. For the evaluated MVs, Doppler pressure gradients exhibited good agreement with catheter-measured gradients at a variety of flow rates, though with slight systematic overestimation in the recreated MAC valves. For all of the tested MVs, measuring the transmitral pressure gradient at differing valve orifice positions had minimal impact on observed gradients. Upon the testing of additional normal and calcific MVs, these data may contribute to an improved clinical understanding of MAC-related mitral stenosis. Moreover, they provide the ability to statistically evaluate between measurement locations, flow rates, and valve geometries for Doppler-derived pressure gradients. Determining these end points will contribute to greater clinical understanding for the diagnosis MAC patients and understanding the use and application of Doppler echocardiography to estimate transmitral pressure gradients.
Collapse
Affiliation(s)
- Tarrah A Herrmann
- The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA 30332, USA
| | | | | | | | | | | | | |
Collapse
|
5
|
Percutaneous mitral repair with MitraClip system; safety and efficacy; initial Egyptian experience. Egypt Heart J 2014. [DOI: 10.1016/j.ehj.2013.09.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
|
6
|
Bhattacharya S, Pham T, He Z, Sun W. Tension to passively cinch the mitral annulus through coronary sinus access: an ex vivo study in ovine model. J Biomech 2014; 47:1382-8. [PMID: 24607007 DOI: 10.1016/j.jbiomech.2014.01.044] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2013] [Revised: 01/22/2014] [Accepted: 01/23/2014] [Indexed: 11/29/2022]
Abstract
INTRODUCTION The transcatheter mitral valve repair (TMVR) technique utilizes a stent to cinch a segment of the mitral annulus (MA) and reduces mitral regurgitation. The cinching mechanism results in reduction of the septal-lateral distance. However, the mechanism has not been characterized completely. In this study, a method was developed to quantify the relation between cinching tension and MA area in an ex vivo ovine model. METHOD The cinching tension was measured from a suture inserted within the coronary sinus (CS) vessel with one end tied to the distal end of the vessel and the other end exited to the CS ostium where it was attached to a force transducer on a linear stage. The cinching tension, MA area, septal-lateral (S-L) and commissure-commissure (C-C) diameters and leakage was simultaneously measured in normal and dilated condition, under a hydrostatic left ventricular pressure of 90 mm Hg. RESULTS The MA area was increased up to 22.8% after MA dilation. A mean tension of 2.1 ± 0.5 N reduced the MA area by 21.3 ± 5.6% and S-L diameter by 24.2 ± 5.3%. Thus, leakage was improved by 51.7 ± 16.2% following restoration of normal MA geometry. CONCLUSION The cinching tension generated by the suture acts as a compensation force in MA reduction, implying the maximum tension needed to be generated by annuloplasty device to restore normal annular size. The relationship between cinching tension and the corresponding MA geometry will contribute to the development of future TMVR devices and understanding of myocardial contraction function.
Collapse
Affiliation(s)
- Shamik Bhattacharya
- Tissue Mechanics Laboratory Biomedical Engineering Program and Department of Mechanical Engineering University of Connecticut, Storrs, CT 06269, United States
| | - Thuy Pham
- Tissue Mechanics Laboratory Biomedical Engineering Program and Department of Mechanical Engineering University of Connecticut, Storrs, CT 06269, United States
| | - Zhaoming He
- Department of Mechanical Engineering Texas Tech University, Lubbock, TX 79409, United States
| | - Wei Sun
- Tissue Mechanics Laboratory Biomedical Engineering Program and Department of Mechanical Engineering University of Connecticut, Storrs, CT 06269, United States.
| |
Collapse
|
7
|
Platts DG, Hilton A, Diab S, McDonald C, Tunbridge M, Chemonges S, Dunster KR, Shekar K, Burstow DJ, Fraser JF. A novel echocardiographic imaging technique, intracatheter echocardiography, to guide veno-venous extracorporeal membrane oxygenation cannulae placement in a validated ovine model. Intensive Care Med Exp 2014; 2:2. [PMID: 26266903 PMCID: PMC4512982 DOI: 10.1186/2197-425x-2-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2013] [Accepted: 12/09/2013] [Indexed: 11/24/2022] Open
Abstract
Background Echocardiography plays a fundamental role in cannulae insertion and positioning for extracorporeal membrane oxygenation (ECMO). Optimal access and return cannulae orientation is required to prevent recirculation. The aim of this study was to compare a novel imaging technique, intracatheter echocardiography (iCATHe), with conventional intracardiac echocardiography (ICE) to guide placement of ECMO access and return venous cannulae. Methods Twenty sheep were commenced on veno-venous ECMO (VV ECMO). Access and return ECMO cannulae were positioned using an ICE-guided technique. Following the assessment of cannulae position, the ICE probe was then introduced inside the cannulae, noting location of the tip. After 24 h, the sheep were euthanized and cannulae position was determined at post mortem. The two-tailed McNemar test was used to compare iCATHe with ICE cannulae positioning. Results ICE and iCATHe imaging was possible in all 20 sheep commenced on ECMO. There was no significant difference between the two methods in assessing access cannula position (proportion correct for each 90%, incorrect 10%). However, there was a significant difference between ICE and iCATHe success rates for the return cannula (p = 0.001). Proportion correct for iCATHe and ICE was 80% and 15% respectively. iCATHe was 65% more successful (95% CI 27% to 75%) at predicting the placement of the return cannula. There were no complications related to the ICE or iCATHe imaging. Conclusion iCATHe is a safe and feasible imaging technique to guide real-time VV ECMO cannulae placement and improves accuracy of return cannula positioning compared to ICE. Electronic supplementary material The online version of this article (doi:10.1186/2197-425X-2-2) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- David G Platts
- Department of Echocardiography, Cardiac Investigations Unit, The Prince Charles Hospital, Rode Rd., Chermside, Brisbane, Queensland, 4032, Australia,
| | | | | | | | | | | | | | | | | | | |
Collapse
|
8
|
Abstract
We are entering a new era in the percutaneous treatment of valvular heart disease. Novel techniques and devices have given rise to the possible treatment of a range of valvular heart diseases that previously necessitated surgical therapies, including aortic stenosis, pulmonary regurgitation and mitral regurgitation. Despite the enormous potential of these percutaneous therapies, enthusiasm needs to be balanced by an understanding of the challenges that need to be overcome before such therapies can be widely embraced. This review provides a critical assessment of the status of the major developments in percutaneous valvular intervention to date, and provides the authors' perspective on the current role and future potential of these techniques.
Collapse
Affiliation(s)
- Ivan P Casserly
- Director of Cardiovascular Intervention, Denver VA Medical Center, Department of Cardiology, 1055 Clermont Street, Denver, CO 80220, USA.
| | | |
Collapse
|
9
|
Pham T, Sun W. Material properties of aged human mitral valve leaflets. J Biomed Mater Res A 2013; 102:2692-703. [PMID: 24039052 DOI: 10.1002/jbm.a.34939] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2013] [Revised: 08/01/2013] [Accepted: 08/26/2013] [Indexed: 11/08/2022]
Abstract
This study aimed to characterize the mechanical properties of aged human anterior mitral leaflets (AML) and posterior mitral leaflets (PML). The AML and PML samples from explanted human hearts (n = 21, mean age of 82.62 ± 8.77-years-old) were subjected to planar biaxial mechanical tests. The material stiffness, extensibility, and degree of anisotropy of the leaflet samples were quantified. The microstructure of the samples was assessed through histology. Both the AML and PML samples exhibited a nonlinear and anisotropic behavior with the circumferential direction being stiffer than the radial direction. The AML samples were significantly stiffer than the PML samples in both directions, suggesting that they should be modeled with separate sets of material properties in computational studies. Histological analysis indicated the changes in the tissue elastic constituents, including the fragmented and disorganized elastin network, the presence of fibrosis and proteoglycan/glycosaminoglycan infiltration and calcification, suggesting possible valvular degenerative characteristics in the aged human leaflet samples. Overall, stiffness increased and areal strain decreased with calcification severity. In addition, leaflet tissues from hypertensive individuals also exhibited a higher stiffness and low areal strain than normotensive individuals. There are significant differences in the mechanical properties of the two human mitral valve leaflets from this advanced age group. The morphologic changes in the tissue composition and structure also infer the structural and functional difference between aged human valves and those of animals.
Collapse
Affiliation(s)
- Thuy Pham
- Tissue Mechanics Laboratory, Department of Mechanical Engineering, Biomedical Engineering Program, University of Connecticut, Storrs, Connecticut, 06269
| | | |
Collapse
|
10
|
Konerding MA, Simpanen J, Ihlberg L, Aittomäki J, Werkkala K, Delventhal V, Ackermann M. Comparison of the novel Medtentia double helix mitral annuloplasty system with the Carpentier-Edwards Physio annuloplasty ring: morphological and functional long-term outcome in a mitral valve insufficiency sheep model. J Cardiothorac Surg 2013; 8:70. [PMID: 23566678 PMCID: PMC3681631 DOI: 10.1186/1749-8090-8-70] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2012] [Accepted: 03/25/2013] [Indexed: 11/25/2022] Open
Abstract
Background The prevalence of mitral regurgitation in cardiac diseases requires annuloplasty systems that can be implanted without excessive patient burden. This study was designed to examine the morphological and functional outcome of a new double helix mitral annuloplasty ring in an ovine model in comparison to the classical Carpentier-Edwards (CE) annuloplasty ring as measured by reduction of mitral regurgitation and tissue integration. The Medtentia annuloplasty ring (MAR) is a helical device that is rotated into the annulus self-restoring the valve geometry, enabling a faster fixation without the need of elaborate repair of the valve geometry. The ventricular part of the helical ring encircles the valve chords. Methods Twenty adult sheep were overpaced until 2+ level mitral valve regurgitation was achieved. Seven animals per group received either the MAR or the CE ring. Implantation was performed on-pump in a beating heart through the left atrial appendix. The animals were sacrificed 3.6 ± 0.3 months after surgery following an echocardiography for assessing mitral regurgitation as primary endpoint. The annuloplasty rings with surrounding tissue were harvested for histological analyses as secondary endpoints. The remaining six sheep received the MAR system and were sampled seven, nine or 12 months after surgery. Results Implantation time (p < 0.01) and perfusion time (p < 0.001) as clinical secondary endpoints were significantly shorter in the MAR group. Echocardiography follow-ups showed sufficient valve function repair in nearly all animals with a normalization of the ventricle diameters in both groups (group difference: p = 0.147). The weights of the hearts did not differ significantly. Histology revealed adequately covered atrial annuloplasty rings with functional endothelium and lack of excessive granulation tissue or fibrosis in all specimens. The ventricular projections of the MAR systems encircling the chordae tendineae were not completely covered with neointimal tissue, although in no case were microthrombi detected and no thromboembolic events were recorded. Conclusions The new MAR system is an easy to use annuloplasty system with a functional outcome comparable to that of the well–proven CE ring. Mitral valve regurgitation is effectively stopped both by restricting the pathological expansion of the annulus and by gathering the chords without thrombus formation.
Collapse
|
11
|
Atluri P, Acker MA. Mitral valve surgery for dilated cardiomyopathy: current status and future roles. Semin Thorac Cardiovasc Surg 2012; 24:51-8. [PMID: 22643662 DOI: 10.1053/j.semtcvs.2012.04.008] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/11/2012] [Indexed: 11/11/2022]
Abstract
There are a large number of patients with functional mitral regurgitation resulting from dilated cardiomyopathy. The decision between surgical correction and medical management of severe mitral regurgitation in heart failure can be difficult. The data regarding long-term benefits and mortality after surgical intervention are contradictory. Recent data suggest that mitral regurgitation can be surgically corrected in heart failure with symptomatic improvements and beneficial reverse remodeling. Contrary to prior beliefs, mitral valve repair can be performed safely with minimal postoperative mortality. Data from multi-institutional, randomized prospective trials will help to elucidate many of the questions and concerns regarding repair of severe functional mitral regurgitation.
Collapse
Affiliation(s)
- Pavan Atluri
- Division of Cardiovascular Surgery, Department of Surgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania 19104, USA
| | | |
Collapse
|
12
|
Lago RM, Cubeddu RJ, Palacios IF. Percutaneous Techniques for the Treatment of Patients with Functional Mitral Valve Regurgitation. Interv Cardiol Clin 2012; 1:85-99. [PMID: 28582070 DOI: 10.1016/j.iccl.2011.10.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Percutaneous approaches to mitral regurgitation remain largely investigational. In the last decade, novel percutaneous strategies have opened new options in the treatment of valvular heart disease. Several studies are currently underway to determine the benefits of transcatheter mitral valve repair therapy. Transcatheter chordal procedures are being developed, including chordal cutting and chordal implantation. Transcatheter valve implantation in the mitral position might offer a desirable alternative in selected patients and has been accomplished in a compassionate fashion on rare occasions in patients who are not candidates for surgical valve repair or replacement.
Collapse
Affiliation(s)
- Rodrigo M Lago
- Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, Boston, MA 02114, USA
| | - Roberto J Cubeddu
- Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, Boston, MA 02114, USA
| | - Igor F Palacios
- Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, Boston, MA 02114, USA.
| |
Collapse
|
13
|
Warraich HJ, Shahul S, Matyal R, Mahmood F. Bench to Bedside: Dynamic Mitral Valve Assessment. J Cardiothorac Vasc Anesth 2011; 25:863-6. [DOI: 10.1053/j.jvca.2011.06.021] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/15/2011] [Indexed: 11/11/2022]
|
14
|
Comparison of biaxial mechanical properties of coronary sinus tissues from porcine, ovine and aged human species. J Mech Behav Biomed Mater 2011; 6:21-9. [PMID: 22301170 DOI: 10.1016/j.jmbbm.2011.09.001] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2011] [Revised: 08/31/2011] [Accepted: 09/02/2011] [Indexed: 11/22/2022]
Abstract
Due to its proximity to the mitral valve, the coronary sinus (CS) vessel serves as a conduit for the deployment and implantation of the percutaneous transvenous mitral annuloplasty (PTMA) devices that can potentially reduce the mitral regurgitation. Because CS vessel is a venous tissue and seldom diseased, its mechanical properties have not been well studied. In this study, we performed a multi-axial mechanical test and histological analysis to characterize the mechanical and structural properties of the aged human, porcine and ovine CS tissues. The results showed that the aged human CS tissues exhibited much stiffer and highly anisotropic behaviors compared to the porcine and ovine. Both of the porcine and ovine CS vessel walls were thicker and mainly composed of striated muscle fibers (SMF), whereas the thinner aged human CS had higher collagen, less SMF, and more fragmented elastin fibers, which are possibly due to aging effects. We also observed that the anatomical features of porcine CS vessel might be not suitable for PTMA deployment. These differences between animal and human models raise questions for the validity of using animal models to investigate the biomechanics involved in the PTMA intervention. Therefore, caution must be taken in future studies of PTMA stents using animal models.
Collapse
|
15
|
Bertog SC, Franke J, Steinberg DH, Wunderlich N, Sievert H. Percutaneous approaches to mitral valve regurgitation. Herz 2011; 37:172-82. [PMID: 21748386 DOI: 10.1007/s00059-011-3490-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Mitral regurgitation is a common problem associated with significant morbidity and mortality. Mitral valve surgery has been the treatment of choice for symptomatic patients with severe mitral regurgitation or asymptomatic patients with high-risk clinical features. However, a significant number of patients remain untreated related mainly due to a projected high surgical risk. Therefore, alternative percutaneous treatments including indirect annuloplasty, which takes advantage of the coronary sinus, and direct annuloplasty have recently been explored. Most recently, promising results of the first randomized trial comparing conventional mitral valve surgery to percutaneous therapy with a clip creating a double orifice much like the surgical Alfieri approach have been presented. Finally, percutaneous mitral valve replacement in an animal model has been pursued. This review serves to familiarize the reader with some anatomical concepts and devices for percutaneous mitral repair.
Collapse
Affiliation(s)
- S C Bertog
- CardioVascular Center Frankfurt, Seckbacher Landstrasse 65, Frankfurt, Germany
| | | | | | | | | |
Collapse
|
16
|
van Mieghem NM, Schultz CJ, Spencer R, Serruys PW, de Jaegere PP. Transcatheter indirect mitral annuloplasty with the PTMA system: a technical report. EUROINTERVENTION 2011; 7:164-9. [PMID: 21550919 DOI: 10.4244/eijv7i1a27] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Nicolas M van Mieghem
- Department of Interventional Cardiology, Thoraxcenter, Erasmus Medical Center, Rotterdam, The Netherlands.
| | | | | | | | | |
Collapse
|
17
|
Abstract
PURPOSE OF REVIEW The rapid advancement in transcatheter therapies seeks to provide less invasive options compared with conventional surgery in the treatment of acquired valvular heart disease. A number of transcatheter mitral valve devices using a variety of approaches for the treatment of mitral regurgitation are under development or in early clinical application. Although yet to be clearly defined, there is no doubt that transcatheter mitral valve procedures will have a significant role alongside conventional surgery. The question is: will surgeons, who have led the treatment of mitral valve disease for the past 30 years, have a role in these procedures? RECENT FINDINGS In order to answer this question, this review discusses key understanding of mitral valve anatomy, function and disorder required to perform transcatheter mitral valve interventions. It assesses the potential role of transcatheter therapies with particular reference to percutaneous edge-to-edge repair using the Mitraclip system (Abbott Vascular Devices, California, USA). The new era in collaboration between surgeons and cardiologists is discussed and the potential role of the surgeon in percutaneous mitral valve procedures is examined. SUMMARY Transcatheter mitral valve procedures demand increasing collaboration between cardiologists and surgeons in order to achieve optimal outcomes. Interventional cardiologists will require dedicated training in the specialized field of transcatheter interventions in acquired structural heart diseases. As the delivery of such therapies brings the interface between interventional cardiology and cardiac surgery ever closer, there is the potential for a niche area in cardiac surgery to develop comprising minimally invasive surgical and transcatheter skills.
Collapse
|
18
|
Mahmood F, Gorman JH, Subramaniam B, Gorman RC, Panzica PJ, Hagberg RC, Lerner AB, Hess PE, Maslow A, Khabbaz KR. Changes in mitral valve annular geometry after repair: saddle-shaped versus flat annuloplasty rings. Ann Thorac Surg 2010; 90:1212-20. [PMID: 20868816 DOI: 10.1016/j.athoracsur.2010.03.119] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/08/2009] [Revised: 03/17/2010] [Accepted: 03/22/2010] [Indexed: 11/28/2022]
Abstract
BACKGROUND Saddle-shaped annuloplasty rings are being increasingly used during mitral valve (MV) repair to conform the mitral annulus to a more nonplanar shape and possibly reduce leaflet stress. In this study utilizing three-dimensional transesophageal echocardiography we compared the effects of rigid flat rings with those of the saddle rings on the mitral annular geometry. Specifically we measured the changes in nonplanarity angle (NPA) before and after MV repair. METHODS Geometric analysis on 38 patients undergoing MV repair for myxomatous and ischemic mitral regurgitation with full flat rings (n = 18) and saddle rings (n = 18) were performed. The acquired three-dimensional volumetric data were analyzed utilizing the "Image Arena" software (TomTec GmBH, Munich, Germany). Specifically, the degree of change in the NPA was calculated and compared before and after repair for both types of rings. RESULTS Both types of annuloplasty rings resulted in significant changes in the geometric structure of the MV after repair. However, saddle rings lead to a decrease in the NPA (7% for ischemic and 8% for myxomatous MV repairs) (ie, made the annulus more nonplanar), whereas flat rings increased the NPA (7.9% for ischemic and 11.8% for myxomatous MV repairs) (ie, made the annulus less nonplanar); p value 0.001 or less. CONCLUSIONS Implantation of saddle-shaped rings during MV repair surgery is associated with augmentation of the nonplanar shape of the mitral annulus (ie, decreases NPA). This favorable change in the mitral annular geometry could possibly confer a structural advantage to MV repairs with the saddle rings.
Collapse
Affiliation(s)
- Feroze Mahmood
- Department of Anesthesia and Critical Care, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
19
|
Rahman S, Eid N, Murarka S, Heuser RR. Remodeling of the mitral valve using radiofrequency energy: review of a new treatment modality for mitral regurgitation. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2010; 11:249-59. [DOI: 10.1016/j.carrev.2009.10.004] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2009] [Revised: 10/16/2009] [Accepted: 10/26/2009] [Indexed: 11/30/2022]
|
20
|
Yeo KK, Davenport J, Raff G, Laird JR. Life-threatening coronary sinus thrombosis following catheter ablation: case report and review of literature. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2010; 11:262.e1-5. [DOI: 10.1016/j.carrev.2010.01.003] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2009] [Accepted: 01/07/2010] [Indexed: 11/30/2022]
|
21
|
The pre-clinical animal model in the translational research of interventional cardiology. JACC Cardiovasc Interv 2010; 2:373-83. [PMID: 19463458 DOI: 10.1016/j.jcin.2009.03.004] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/18/2008] [Revised: 02/19/2009] [Accepted: 03/08/2009] [Indexed: 11/23/2022]
Abstract
Scientific discoveries for improvement of human health must be translated into practical applications. Such discoveries typically begin at "the bench" with basic research, then progress to the clinical level. In particular, in the field of interventional cardiology, percutaneous cardiovascular intervention has rapidly evolved from an experimental procedure to a therapeutic clinical setting. Pre-clinical studies using animal models play a very important role in the evaluation of efficacy and safety of new medical devices before their use in human clinical studies. This review provides an overview of the emerging role, results of pre-clinical studies and development, and evaluation of animal models for percutaneous cardiovascular intervention technologies for patients with symptomatic cardiovascular disease.
Collapse
|
22
|
Taramasso M, Cioni M, Giacomini A, Michev I, Godino C, Montorfano M, Colombo A, Alfieri O, Maisano F. Emerging approaches of transcatheter valve repair/insertion. Cardiol Res Pract 2010; 2010. [PMID: 20811476 PMCID: PMC2926577 DOI: 10.4061/2010/540749] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2010] [Revised: 06/20/2010] [Accepted: 06/21/2010] [Indexed: 11/20/2022] Open
Abstract
Aortic stenosis (AS) and mitral regurgitation (MR) account for the majority of valvular diseases and their prevalence is increasing according to increased life expectancy. Surgical treatment is the gold standard, although operative risk may be high in some patients due to comorbidities and age. A large part of the patients at high surgical risk who could beneficiate of treatment are not referred to surgery. Therefore, there is a need of alternative and less invasive procedures.
Collapse
Affiliation(s)
- Maurizio Taramasso
- Cardiothoracic Department, San Raffaele Scientific Institute, via Olgettina 60, 20122 Milan, Italy
| | | | | | | | | | | | | | | | | |
Collapse
|
23
|
Engström AE, Vis MM, Bouma BJ, Claessen BE, Sjauw KD, Baan J, Meuwissen M, Koch KT, de Winter RJ, Tijssen JG, Piek JJ, Henriques JP. Mitral regurgitation is an independent predictor of 1-year mortality in ST-elevation myocardial infarction patients presenting in cardiogenic shock on admission. ACTA ACUST UNITED AC 2010; 12:51-7. [DOI: 10.3109/17482941003802148] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
24
|
Jilaihawi H, Virmani R, Nakagawa H, Ducharme A, Shi YF, Carter-Monroe N, Ladich E, Iyer M, Ikeda A, Asgar A, Bonan R. Mitral annular reduction with subablative therapeutic ultrasound: pre-clinical evaluation of the ReCor device. EUROINTERVENTION 2010. [DOI: 10.4244/eijv6i1a9] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
25
|
Franzen O, Baldus S, Rudolph V, Meyer S, Knap M, Koschyk D, Treede H, Barmeyer A, Schofer J, Costard-Jäckle A, Schlüter M, Reichenspurner H, Meinertz T. Acute outcomes of MitraClip therapy for mitral regurgitation in high-surgical-risk patients: emphasis on adverse valve morphology and severe left ventricular dysfunction. Eur Heart J 2010; 31:1373-81. [PMID: 20219746 DOI: 10.1093/eurheartj/ehq050] [Citation(s) in RCA: 233] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/28/2023] Open
Abstract
AIMS We sought to assess the feasibility of catheter-based mitral valve repair using the MitraClip system in high-surgical-risk patients with mitral regurgitation (MR) > or =grade 3+. METHODS AND RESULTS MitraClip therapy was performed in 51 consecutive patients [73 +/- 10 years; 34 (67%) men] with symptomatic functional [n = 35 (69%)] or organic MR [n = 16 (31%)]. Mean logistic EuroSCORE was 29 +/- 22%; Society of Thoracic Surgeons score was 15 +/- 11. Left ventricular (LV) ejection fraction was 36 +/- 17%. In 35 patients (69%), adverse mitral valve morphology and/or severe LV dysfunction were present. MitraClip implantation was successful in 49 patients (96%). Most patients [n = 34/49 (69%)] were treated with a single clip, whereas 14 patients (29%) received two clips and one patient received three clips. Mean device and fluoroscopy times were 105 +/- 65 min and 44 +/- 28 min, respectively. Procedure-related reduction in MR severity was one grade in 16 patients (31%), two grades in 24 patients (47%), and three grades in 9 patients (18%). Forty-four of the 49 successfully treated patients (90%) showed clinical improvement at discharge [NYHA functional class > or =III in 48 patients (98%) before and 16 patients (33%) after the procedure (P < 0.0001)]. There were no procedure-related major adverse events and no in-hospital mortality. CONCLUSION Mitral valve repair using the MitraClip system was shown to be feasible in patients at high surgical risk primarily determined by an adverse mitral valve morphology and/or severe LV dysfunction.
Collapse
Affiliation(s)
- Olaf Franzen
- Department of General and Interventional Cardiology, University Heart Centre, Hamburg, Germany.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
26
|
|
27
|
Mahmood F, Subramaniam B, Gorman JH, Levine RM, Gorman RC, Maslow A, Panzica PJ, Hagberg RM, Karthik S, Khabbaz KR. Three-dimensional echocardiographic assessment of changes in mitral valve geometry after valve repair. Ann Thorac Surg 2010; 88:1838-44. [PMID: 19932245 DOI: 10.1016/j.athoracsur.2009.07.007] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/02/2009] [Revised: 06/27/2009] [Accepted: 07/02/2009] [Indexed: 11/19/2022]
Abstract
BACKGROUND Application of annuloplasty rings during mitral valve (MV) repair has been shown to significantly change the mitral annular geometry. Until recently, a comprehensive two-dimensional echocardiographic evaluation of annular geometric changes was difficult owing to its nonplanar orientation. In this study, an analysis of the three-dimensional intraoperative transesophageal echocardiographic evaluation of the MV annulus is presented before and immediately after repair. METHODS We performed three-dimensional geometric analysis on 75 patients undergoing MV repair during coronary artery bypass graft surgery for mitral regurgitation or myxomatous mitral valve disease. Geometric analysis of the MV was performed before and immediately after valve repair with full rings and annuloplasty bands. The acquired three-dimensional volumetric data were analyzed in the operating room. Specific measurements included annular diameter, leaflet lengths, the nonplanarity angle, and the circularity index. Before and after repair data were compared. RESULTS Complete echocardiographic assessment of the MV was feasible in 69 of 75 patients (92%) within 2 to 3 minutes of acquisition. Placement of full rings resulted in an increase in the nonplanarity angle or a less saddle shape of the native mitral annulus (137 +/- 14 versus 146 +/- 14; p = 0.002. By contrast, the nonplanarity angle did not change significantly after placement of partial rings. CONCLUSIONS Mitral annular nonplanarity can be assessed in the operating room. Application of full annuloplasty rings resulted in the mitral annulus becoming more planar. Partial annuloplasty bands did not significantly change the nonplanarity angle. Neither of the two types of rings restored the native annular planarity.
Collapse
Affiliation(s)
- Feroze Mahmood
- Department of Anesthesia and Critical Care and Pain Management, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
28
|
Acute Feasibility Study of a Novel Device for the Treatment of Mitral Regurgitation in a Normal Canine Model. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2010; 5:28-32. [DOI: 10.1097/imi.0b013e3181cdf735] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Objective The purpose of this study was to evaluate the implantability of a novel epicardial mitral annuloplasty device and its ability to reduce the septal-lateral (S-L) dimension of the mitral annulus. Methods The devices were implanted on the beating heart in 2 healthy dogs (the 24-mm long device in dog A and the 27-mm and 24-mm standard devices in dog B) by sliding the anterior arm onto the floor of the transverse sinus and positioning the posterior arm just apical to the atrioventricular groove on the left ventricular posterolateral wall. The devices were secured with titanium helical tacks driven through the device into the ventricular wall. Two-dimensional epicardial echocardiograms were performed before and after device implantation to evaluate the degree of mitral regurgitation (MR) and the S-L dimension. Results Device implantation was uneventful, taking only ~30 seconds to deploy. MR (1 +) in both dogs at baseline was reduced to zero after implant. The reductions in S-L dimension in systole for the 24-mm device were 7.5% in dog A and 30.5% in dog B. For the 27-mm device in dog B, S-L reduction in systole was 29.9%. The leaflet coaptation length was increased in both cases. Conclusions The new device was effective in reducing S-L dimension and 1 + MR without requiring the use of cardiopulmonary bypass. We are currently evaluating this device for the treatment of MR in a rapid-pacing canine heart failure model.
Collapse
|
29
|
Takaseya T, Fumoto H, Saraiva RM, Shiose A, Arakawa Y, Park M, Rao S, Dessoffy R, Kramer LD, Juravic M, Lombardi P, Fukamachi K. Acute Feasibility Study of a Novel Device for the Treatment of Mitral Regurgitation in a Normal Canine Model. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2010. [DOI: 10.1177/155698451000500107] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Affiliation(s)
- Tohru Takaseya
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH USA
| | - Hideyuki Fumoto
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH USA
| | - Roberto M. Saraiva
- Department of Cardiovascular Medicine, Heart and Vascular Institute, Cleveland Clinic, Cleveland, OH USA
| | - Akira Shiose
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH USA
| | - Yoko Arakawa
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH USA
| | - Margaret Park
- Department of Cardiovascular Medicine, Heart and Vascular Institute, Cleveland Clinic, Cleveland, OH USA
| | - Santosh Rao
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH USA
| | - Raymond Dessoffy
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH USA
| | - Larry D. Kramer
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH USA
| | | | | | - Kiyotaka Fukamachi
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH USA
| |
Collapse
|
30
|
Percutaneous mitral annuloplasty device leaves free access to cardiac veins for resynchronization therapy. Catheter Cardiovasc Interv 2009; 74:506-11. [DOI: 10.1002/ccd.22097] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
|
31
|
Kim JH, Kocaturk O, Ozturk C, Faranesh AZ, Sonmez M, Sampath S, Saikus CE, Kim AH, Raman VK, Derbyshire JA, Schenke WH, Wright VJ, Berry C, McVeigh ER, Lederman RJ. Mitral cerclage annuloplasty, a novel transcatheter treatment for secondary mitral valve regurgitation: initial results in swine. J Am Coll Cardiol 2009; 54:638-51. [PMID: 19660696 DOI: 10.1016/j.jacc.2009.03.071] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/23/2008] [Revised: 03/09/2009] [Accepted: 03/10/2009] [Indexed: 12/23/2022]
Abstract
OBJECTIVES We developed and tested a novel transcatheter circumferential annuloplasty technique to reduce mitral regurgitation in porcine ischemic cardiomyopathy. BACKGROUND Catheter-based annuloplasty for secondary mitral regurgitation exploits the proximity of the coronary sinus to the mitral annulus, but is limited by anatomic variants and coronary artery entrapment. METHODS The procedure, "cerclage annuloplasty," is guided by magnetic resonance imaging (MRI) roadmaps fused with live X-ray. A coronary sinus guidewire traverses a short segment of the basal septal myocardium to re-enter the right heart where it is exchanged for a suture. Tension is applied interactively during imaging and secured with a locking device. RESULTS We found 2 feasible suture pathways from the great cardiac vein across the interventricular septum to create cerclage. Right ventricular septal re-entry required shorter fluoroscopy times than right atrial re-entry, which entailed a longer intramyocardial traversal but did not cross the tricuspid valve. Graded tension progressively reduced septal-lateral annular diameter, but not end-systolic elastance or regional myocardial function. A simple arch-like device protected entrapped coronary arteries from compression even during supratherapeutic tension. Cerclage reduced mitral regurgitation fraction (from 22.8 +/- 12.7% to 7.2 +/- 4.4%, p = 0.04) by slice tracking velocity-encoded MRI. Flexible cerclage reduced annular size but preserved annular motion. Cerclage also displaced the posterior annulus toward the papillary muscles. Cerclage introduced reciprocal constraint to the left ventricular outflow tract and mitral annulus that enhanced leaflet coaptation. A sample of human coronary venograms and computed tomography angiograms suggested that most have suitable venous anatomy for cerclage. CONCLUSIONS Transcatheter mitral cerclage annuloplasty acutely reduces mitral regurgitation in porcine ischemic cardiomyopathy. Entrapped coronary arteries can be protected. MRI provided insight into the mechanism of cerclage action.
Collapse
Affiliation(s)
- June-Hong Kim
- Translational Medicine Branch, Division of Intramural Research, National Heart Lung and Blood Institute, NIH, Bethesda, MD 20892-1538, USA
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
32
|
Effectiveness and safety of percutaneous coronary sinus-based mitral valve repair in patients with dilated cardiomyopathy (from the AMADEUS trial). Am J Cardiol 2009; 104:565-70. [PMID: 19660613 DOI: 10.1016/j.amjcard.2009.04.021] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/07/2009] [Revised: 04/13/2009] [Accepted: 04/13/2009] [Indexed: 11/22/2022]
Abstract
This report presents the procedural results from the AMADEUS trial that support coronary sinus (CS)-based percutaneous mitral annuloplasty. Despite therapeutic advances, functional mitral regurgitation (MR) continues to be a significant clinical problem for patients with dilated cardiomyopathy. CS approaches to mitral valve repair have been viewed with skepticism because of the distance of the CS/great cardiac vein from the mitral valve annulus and the potential to compress a coronary artery. This report presents the procedural results from the AMADEUS trial that support CS-based percutaneous mitral annuloplasty. Patients who met the inclusion criteria were eligible to receive a mitral annuloplasty device. Transesophageal echocardiography was used to assess changes in MR, angiography was used to assess the coronary arteries, and multislice computed tomography was used to evaluate the anatomic relations between the coronary venous system and the mitral valve. Acute MR reduction (grade 3.0 +/- 0.6 to 2.0 +/- 0.8, p <0.0001) and permanent implantation were achieved in 30 of 43 patients in whom an attempt was made. Additional measurements in 20 patients with implants showed reductions in the vena contracta (0.69 +/- 0.29 to 0.46 +/- 0.26 cm, p <0.0001), effective regurgitant orifice area (0.33 +/- 0.17 to 0.19 +/- 0.08 cm(2), p <0.0001), regurgitant volume (40 +/- 20 to 24 +/- 11 ml, p = 0.0005), and jet area/left atrial area (45 +/- 13% to 32 +/- 12%, p <0.0001). The coronary arteries were crossed in 36 patients (84%). Arterial compromise contributed to a lack of implantation in 6 patients (14%). No difference was found in the CS/great cardiac vein position relative to the annulus between the patients who did and did not have a reduction in MR. In conclusion, percutaneous mitral annuloplasty reduces MR and permanent implantation can be achieved in most eligible patients.
Collapse
|
33
|
Warin-Fresse K, Isnard J, Guérin P, N'guyen J, Bammert A, Crochet D. [Coronary CTA evaluation of the relationship between mitral valve annulus and coronary circulation: implications for percutaneous mitral annuloplasty]. ACTA ACUST UNITED AC 2009; 90:725-30. [PMID: 19623125 DOI: 10.1016/s0221-0363(09)74727-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
PURPOSE To evaluate anatomical relationships between mitral annulus (MA), coronary arteries and coronary sinus (CS) in two groups of patients with and without moderate mitral insufficiency on coronary CTA to identify candidates to percutaneous mitral valve annuloplasty via the coronary sinus without risk of coronary artery occlusion. MATERIALS AND METHODS. Fifty-one ECG-gated coronary CTA examinations, obtained during injection of iodinated contrast material on a 16 MDCT were retrospectively reviewed. The mitral valve annulus diameter, anatomical relationships between CS and coronary arteries and MA-CS distance were compared between both patient groups. RESULTS The group with mitral insufficiency included 16 patients and the control group included 35 patients. The AP diameter of the MA was 45,7+/-5,2 mm in the group with mitral insufficiency, significantly larger (p=0.0009) compared to the control group (39,3+/-5,9 mm). In 70.4% of cases, the CS was located next to a coronary artery in an overlapping configuration. The unfavorable anatomical configuration with regards to annuloplasty appeared related to mitral insufficiency (p=0.0539). The distance between MA and CS was greatly variable with the CS routinely extending over the left atrial surface: the distance was significantly (p=0.0002) greater for all patients along the posterior surface (8,1+/-3,8 mm) compared to the lateral surface (5,2+/-4,6 mm) with this différence persisting within both groups: p=0.004 for patients with mitral insufficiency and p=0.0001 for control patients. CONCLUSION Our results demonstrate the value of coronary CTA in selecting candidates to percutaneous mitral annuloplasty. In 70.4% of cases, the CS overlaps a coronary artery with risk of compression at the time of annuloplasty.
Collapse
Affiliation(s)
- K Warin-Fresse
- Centre Hémodynamique et Vasculaire Interventionnel, Institut du Thorax, CHU Nantes, Hôpital GR, Laennec 44093 Nantes Cedex 1.
| | | | | | | | | | | |
Collapse
|
34
|
Tawn Z, Himbert D, Brochet E, Messika-Zeitoun D, Iung B, Vahanian A. Percutaneous valve procedures: Present and future. ACTA ACUST UNITED AC 2009; 7:14-20. [PMID: 16019610 DOI: 10.1080/14628840510011199] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
Percutaneous mitral commissurotomy and aortic valvuloplasty have been being performed since the mid-1980s. Balloon commissurotomy has been used in thousands of cases worldwide and it provides good short- and long-term results in a wide range of patients. It has virtually replaced surgical commissurotomy in the treatment of mitral stenosis. In contrast, percutaneous aortic valvuloplasty is almost abandoned worldwide due to its lack of efficacy and the risks involved. The new techniques of percutaneous valve intervention: aortic valve replacement and mitral valve repair are at an early stage: the first in-man applications of these fledgling techniques started in 2002. Preliminary series show that they are feasible; however, they need to be further evaluated in comparison with contemporary treatment to assess accurately how efficient they are and the risks involved. Currently potential applications concern high-risk patients, however, in the future, after thorough evaluation, this may be extended to others. Thus, percutaneous interventions already play an important role in treatment of valvular heart disease, a role that seems set for future expansion.
Collapse
|
35
|
Abstract
The historic focus of interventional cardiology has been on treating atherosclerotic coronary artery disease. Balloons, stents, and debulking devices have been the mainstay tools of the interventionalist. However, as engineering skills have developed and clinical techniques have improved, new clinical avenues for the interventionalist beyond the coronary vessels are starting to evolve. One of the most opportunistic areas in cardiology for the interventionalist is the left atrium where treatment of clinically important issues such as mitral regurgitation, left atrial thrombus, atrial fibrillation, patent foramen ovale, and atrial septal defect may be approached. Additionally, the left atrium is a source of important hemodynamic information that can be captured with new implantable devices. While in the past the trans-septal puncture has been infrequently used, the future may hold this technique as one of the most common. The following manuscript describes the status of some of the newest opportunities for interventionalists that lie beyond atherosclerotic disease and within the left atrium.
Collapse
Affiliation(s)
- Stephen B Solomon
- Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA
| |
Collapse
|
36
|
Silvestry FE, Kerber RE, Brook MM, Carroll JD, Eberman KM, Goldstein SA, Herrmann HC, Homma S, Mehran R, Packer DL, Parisi AF, Pulerwitz T, Seward JB, Tsang TSM, Wood MA. Echocardiography-guided interventions. J Am Soc Echocardiogr 2009; 22:213-31; quiz 316-7. [PMID: 19258174 DOI: 10.1016/j.echo.2008.12.013] [Citation(s) in RCA: 170] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
A major advantage of echocardiography over other advanced imaging modalities (magnetic resonance imaging, computed tomographic angiography) is that echocardiography is mobile and real time. Echocardiograms can be recorded at the bedside, in the cardiac catheterization laboratory, in the cardiovascular intensive care unit, in the emergency room-indeed, any place that can accommodate a wheeled cart. This tremendous advantage allows for the performance of imaging immediately before, during, and after various procedures involving interventions. The purpose of this report is to review the use of echocardiography to guide interventions. We provide information on the selection of patients for interventions, monitoring during the performance of interventions, and assessing the effects of interventions after their completion. In this document, we address the use of echocardiography in commonly performed procedures: transatrial septal catheterization, pericardiocentesis, myocardial biopsy, percutaneous transvenous balloon valvuloplasty, catheter closure of atrial septal defects (ASDs) and patent foramen ovale (PFO), alcohol septal ablation for hypertrophic cardiomyopathy, and cardiac electrophysiology. A concluding section addresses interventions that are presently investigational but are likely to enter the realm of practice in the very near future: complex mitral valve repairs, left atrial appendage (LAA) occlusion devices, 3-dimensional (3D) echocardiographic guidance, and percutaneous aortic valve replacement. The use of echocardiography to select and guide cardiac resynchronization therapy has recently been addressed in a separate document published by the American Society of Echocardiography and is not further discussed in this document. The use of imaging techniques to guide even well-established procedures enhances the efficiency and safety of these procedures.
Collapse
Affiliation(s)
- Frank E Silvestry
- University of Pennsylvania Health System, Philadelphia, Pennsylvania, USA
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
37
|
Rogers JH, Rahdert DA, Caputo GR, Takeda PA, Palacios IF, Tio FO, Taylor EA, Low RI. Long-term safety and durability of percutaneous septal sinus shortening (The PS(3) System) in an ovine model. Catheter Cardiovasc Interv 2009; 73:540-8. [PMID: 19235241 DOI: 10.1002/ccd.21818] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVES Chronic implants of the PS(3) system were conducted in an ovine model to assess durability and safety at up to 1 year follow-up. BACKGROUND The long-term durability and safety of emerging percutaneous devices for functional mitral regurgitation remain largely unknown. METHODS The PS(3) system (consisting of interatrial septal and great cardiac vein devices connected by an adjustable suture bridge) was placed in eight healthy adult sheep. The mitral annular septal-lateral dimension in systole (SLS) was acutely reduced by 15-20%. Animals were sacrificed at up to 12 months postimplant and characterized by intracardiac echocardiography, cardiac computed tomography (CT), and histopathology. In vivo forces exerted on the PS(3) bridge were measured by means of a novel load cell catheter. RESULTS At 3, 6, and 12 months after implantation, intracardiac echocardiographic and CT showed the PS(3) systems to be intact without erosion and with overall sustained reductions in the SLS. Histopathologic assessment revealed each component correctly deployed in its respective target site without evidence of erosion, thrombus, or device fracture. The SLS was 26.5 +/- 1.7 mm preimplant, 22.0 +/- 1.4 mm post-PS(3) (17.0% reduction), and 22.0 +/- 2.1 mm at latest follow-up. Mean forces exerted on the bridge in vivo ranged from 1.16 N to 1.87 N. CONCLUSIONS The PS(3) System demonstrated excellent biocompatibility without evidence of erosion, thrombosis, or perforation at up to one-year follow-up in this chronic healthy ovine model. Forces exerted in the PS(3) system were relatively modest and should contribute to the durability of the device.
Collapse
Affiliation(s)
- Jason H Rogers
- University of California, Davis Medical Center, Sacramento, California, USA.
| | | | | | | | | | | | | | | |
Collapse
|
38
|
Transcatheter Mitral and Pulmonary Valve Therapy. J Am Coll Cardiol 2009; 53:1837-51. [DOI: 10.1016/j.jacc.2008.12.067] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/12/2008] [Revised: 12/16/2008] [Accepted: 12/23/2008] [Indexed: 10/20/2022]
|
39
|
|
40
|
Faillace RT, Kaddaha R, Bikkina M, Yogananthan T, Parikh R, Casthley P. The role of the out-of-operating room anesthesiologist in the care of the cardiac patient. Anesthesiol Clin 2009; 27:29-46. [PMID: 19361766 DOI: 10.1016/j.anclin.2008.10.006] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Modern invasive cardiovascular procedures require patients to be both comfortable and cooperative. In addition, these procedures demand the complete attention of the attending cardiovascular specialist, and, to a large degree, the outcomes of these procedures depend on the amount of focus and concentration the cardiovascular specialist can give to performing the procedure itself. A team approach using the specialized skills of a cardiologist and an anesthesiologist frequently is required to optimize results. This article clearly delineates the procedures cardiologists perform that might involve anesthesiologists. Mutual knowledge, understanding, and respect are fundamental requirements for integration of cardiology and anesthesia services to optimize patient outcomes.
Collapse
Affiliation(s)
- Robert T Faillace
- St. Joseph's Regional Medical Center, 703 Main Street, Paterson, NJ 07503, USA.
| | | | | | | | | | | |
Collapse
|
41
|
Tops LF, Kapadia SR, Tuzcu EM, Vahanian A, Alfieri O, Webb JG, Bax JJ. Percutaneous Valve Procedures: An Update. Curr Probl Cardiol 2008; 33:417-57. [PMID: 18620099 DOI: 10.1016/j.cpcardiol.2008.05.002] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
42
|
Ghanbari H, Kidane AG, Burriesci G, Bonhoeffer P, Seifalian AM. Percutaneous Heart Valve Replacement: An Update. Trends Cardiovasc Med 2008; 18:117-25. [DOI: 10.1016/j.tcm.2008.02.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/10/2007] [Revised: 02/09/2008] [Accepted: 02/12/2008] [Indexed: 10/22/2022]
|
43
|
Percutaneous and off-pump treatments for functional mitral regurgitation. J Artif Organs 2008; 11:12-8. [DOI: 10.1007/s10047-007-0399-7] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2007] [Indexed: 10/22/2022]
|
44
|
Rosengart TK, Feldman T, Borger MA, Vassiliades TA, Gillinov AM, Hoercher KJ, Vahanian A, Bonow RO, O’Neill W. Percutaneous and Minimally Invasive Valve Procedures. Circulation 2008; 117:1750-67. [DOI: 10.1161/circulationaha.107.188525] [Citation(s) in RCA: 153] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The incidence of valvular heart disease is expected to increase over the next several decades as a large proportion of the US demographic advances into the later decades of life. At the same time, the next several years can be anticipated to bring a broad transition of surgical therapy to minimally invasive (minithoracotomy and small port) access and the more gradual introduction of percutaneous approaches for the correction of valvular heart disease. Broad acceptance of these technologies will require careful and sometimes perplexing comparisons of the outcomes of these new technologies with existing standards of care. The validation of percutaneous techniques, in particular, will require the collaboration of cardiologists and cardiac surgeons in centers with excellent surgical and catheter experience and a commitment to trial participation. For the near term, percutaneous techniques will likely remain investigational and will be limited in use to patients considered to be high risk or to inoperable surgical candidates. Although current-generation devices and techniques require significant modification before widespread clinical use can be adopted, it must be expected that less invasive and even percutaneous valve therapies will likely have a major impact on the management of patients with valvular heart disease over the next several years.
Collapse
|
45
|
Lansac E, Di Centa I, Al Attar N, Messika-Zeitoun D, Raffoul R, Vahanian A, Nataf P. Percutaneous mitral annuloplasty through the coronary sinus: an anatomic point of view. J Thorac Cardiovasc Surg 2008; 135:376-81. [PMID: 18242272 DOI: 10.1016/j.jtcvs.2007.05.071] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/28/2007] [Revised: 04/05/2007] [Accepted: 05/11/2007] [Indexed: 11/18/2022]
Abstract
OBJECTIVE We assessed the anatomic relationships among the mitral annulus, coronary sinus, and circumflex artery in human cadaver hearts. METHODS Percutaneous posterior mitral annuloplasty has been proposed to treat functional mitral regurgitation on the basis of the proximity of the coronary sinus to the mitral annulus. However, concern remains about the ability to perform a trigone-to-trigone posterior annuloplasty and the potential for compromise of the circumflex coronary artery. Ten hearts were studied after injection of expansible foam into the coronary sinus and circumflex artery. The mitral annulus perimeter, posterior intertrigonal (T1-T2) and intercommissural (C1-C2) distance, and coronary sinus projection on the native annulus (S1-S2) were measured. The spatial geometry of the coronary sinus was correlated with the circumflex artery route and the distance with the native mitral annulus. RESULTS The projection of coronary sinus annuloplasty achieves at best a commissure-to-commissure annuloplasty 14.5 (6-24) mm behind each trigone: T1-T2: 74 (56-114) mm, C1-C2: 62.2 (48-80) mm, S1-S2: 59.5 (40-80) mm. The coronary sinus was distant from the native annulus (8-14 mm at the coronary sinus ostium, 13.7-20.4 mm at the middle of the coronary sinus, 6.9-14 mm at the level of the great coronary vein). The circumflex artery was located between the coronary sinus and the mitral annulus in 45.5% of cases. CONCLUSIONS This anatomic study highlights the 3-dimensional structure of the coronary sinus and its distance from the native mitral annulus and fibrous trigones. Human anatomic studies are mandatory for the further development of percutaneous mitral repair technology.
Collapse
Affiliation(s)
- Emmanuel Lansac
- Department of Cardiovascular Surgery, Bichat University Hospital, Assistance Publique Hopitaux de Paris, France.
| | | | | | | | | | | | | |
Collapse
|
46
|
Affiliation(s)
- Ted Feldman
- Evanston Hospital, Cardiology Division, Walgreen Bldg 3rd Floor, 2650 Ridge Ave, Evanston, IL 60201, USA.
| | | |
Collapse
|
47
|
Daimon M, Saracino G, Gillinov AM, Koyama Y, Fukuda S, Kwan J, Song JM, Kongsaerepong V, Agler DA, Thomas JD, Shiota T. Local Dysfunction and Asymmetrical Deformation of Mitral Annular Geometry in Ischemic Mitral Regurgitation: A Novel Computerized 3D Echocardiographic Analysis. Echocardiography 2008; 25:414-23. [DOI: 10.1111/j.1540-8175.2007.00600.x] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
48
|
PIAZZA NICOLO, BONAN RAOUL. Transcatheter Mitral Valve Repair for Functional Mitral Regurgitation: Coronary Sinus Approach. J Interv Cardiol 2007; 20:495-508. [DOI: 10.1111/j.1540-8183.2007.00310.x] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
|
49
|
|
50
|
Sochman J, Peregrin JH. Catheter-based modification of heart valve diseases: from experimental to clinical application. ASAIO J 2007; 53:609-16. [PMID: 17885335 DOI: 10.1097/mat.0b013e31814a5829] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
Efforts to modify cardiac valve defects using catheter-based techniques are increasing at the present time. We present observations on cardiac valve morphology and disease and review the progress being made to address valve defects with these innovative methods. Some new procedures developed through animal experimentation have already been put to use in clinical practice, but the newness of these techniques and the small number of cases in which they have been applied to date precludes an evaluation of their long-term durability. Although at the present time cardiac surgery remains the standard for treating most cases of valve disease, in certain situations a catheter-based treatment might provide a reasonable alternative, even if only temporary, especially for individuals with serious disease who are not suitable candidates for surgery.
Collapse
Affiliation(s)
- Jan Sochman
- Clinic of Cardiology, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| | | |
Collapse
|