1
|
Larsen BC, Harmsen MC, Vase H, Nielsen-Kudsk JE, Andersen A. Comparison of Patent Foramen Ovale Sizing by Transesophageal Echocardiography and Balloon Sizing in Patients Undergoing Percutaneous Closure. STRUCTURAL HEART : THE JOURNAL OF THE HEART TEAM 2025; 9:100375. [PMID: 40017836 PMCID: PMC11864128 DOI: 10.1016/j.shj.2024.100375] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/07/2024] [Revised: 09/24/2024] [Accepted: 09/25/2024] [Indexed: 03/01/2025]
Abstract
Background A patent foramen ovale (PFO) has a complex anatomy, and evaluating the size before closure may be challenging. We aimed to investigate the correlation between preprocedural transesophageal echocardiography (TEE) and balloon sizing of PFO in patients undergoing percutaneous PFO closure. Methods A retrospective single-center study with analysis of 100 patients who, due to paradox thromboembolism in the left circulation, underwent percutaneous PFO closure. The PFO sizing was compared to measures attained by TEE and balloon sizing using linear regression analysis. Results PFO size measured by TEE occurred smaller than balloon sizing (2.19 mm [95% CI: 1.91 to 2.46] vs. 8.51 mm [95% CI: 8.02 to 9.00], p < 0.001). Additionally, neither the PFO channel length nor the atrial septal mobility measured by TEE correlated to the PFO size attained by balloon sizing, respectively (slope -0.018 [95% CI: -0.117 to 0.081], R = 0.036, p = 0.719) and (slope 0.049 [95% CI: ?0.043 to 0.141], R = 0.105, p = 0.297). Statistically significant difference in regression analysis but poor correlation was found between both TEE attained PFO and shunt size when compared to balloon sizing. Diverting patients according to the size of the PFO shunt was not statistically significant between PFO of moderate size compared, respectively, to a large and small PFO size. However, a difference was observed between a small and large PFO shunt size. Conclusions PFO defect and shunt size measured by TEE showed a poor correlation with balloon sizing. Neither PFO channel length nor septal mobility were correlated to the PFO size measured by balloon sizing.
Collapse
Affiliation(s)
- Birgitte Carbuhn Larsen
- Department of Cardiology, Aarhus University Hospital, Aarhus, Denmark
- Department of Internal Medicine, Regional Hospital Randers, Randers, Denmark
| | | | - Henrik Vase
- Department of Cardiology, Aarhus University Hospital, Aarhus, Denmark
| | | | - Asger Andersen
- Department of Cardiology, Aarhus University Hospital, Aarhus, Denmark
| |
Collapse
|
2
|
Piayda K, Bertog S, Mbai M, Sharma A, Veulemans V, Sievert H. Practical Aspects of Patent Foramen Ovale Closure: Ultrasound and Fluoroscopic Guidance. Cardiol Clin 2024; 42:537-545. [PMID: 39322344 DOI: 10.1016/j.ccl.2024.02.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 09/27/2024]
Abstract
Percutaneous PFO closure is a well-established medical procedure to mitigate paradoxic embolism and the future risk of stroke in a well-selected patient clientele. When it comes to procedural guidance during PFO closure, various modalities exist, each with its own advantages and disadvantages. Guidance by transesophageal echocardiography (in combination with fluoroscopy) offers high-resolution 2D/3D imaging, however, it requires the presence of a peri-interventional imager and conscious sedation (or endotracheal intubation). Intracardiac echocardiography and fluoroscopy guidance can be performed by a single operator and omits the need for conscious sedation (or endotracheal intubation).
Collapse
Affiliation(s)
- Kerstin Piayda
- Cardiovascular Center Frankfurt, Frankfurt, Germany; Department of Cardiology and Vascular Medicine, University Hospital Gießen and Marburg, Gießen, Germany
| | - Stefan Bertog
- Cardiovascular Center Frankfurt, Frankfurt, Germany; Minneapolis Veterans Affairs Medical Center, Minneapolis, MN, USA
| | - Mackenzie Mbai
- Minneapolis Veterans Affairs Medical Center, Minneapolis, MN, USA
| | - Alok Sharma
- Minneapolis Veterans Affairs Medical Center, Minneapolis, MN, USA
| | - Verena Veulemans
- Department of Cardiology, Pneumology and Vascular Medicine, University Hospital Düsseldorf, Düsseldorf, Germany
| | - Horst Sievert
- Cardiovascular Center Frankfurt, Frankfurt, Germany.
| |
Collapse
|
3
|
Zhang D, Jiang L, Chen YN, Pan MF. The diagnostic value of contrast-enhanced transcranial Doppler and contrast-enhanced transthoracic echocardiography for right to left shunt in patent foramen ovale: a systematic review and meta-analysis. Front Neurol 2024; 15:1447964. [PMID: 39157064 PMCID: PMC11327031 DOI: 10.3389/fneur.2024.1447964] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2024] [Accepted: 07/25/2024] [Indexed: 08/20/2024] Open
Abstract
Purpose To evaluate and compare the diagnostic value of contrast-enhanced transcranial Doppler (c-TCD) and contrast-enhanced transthoracic echocardiography (c-TTE) for right to left shunt (RLS) in patent foramen ovale (PFO) by meta-analysis. Methods The literature included in the Cochrane Library, PubMed, and Embase were searched by using "contrast-enhanced transcranial Doppler (c-TCD), contrast-enhanced transthoracic echocardiography (c-TTE), patent foramen ovale (PFO), and right to left shunt (RLS)" as the keywords from inception through April 30, 2024. The diagnostic accuracy research quality assessment tool (QUADAS-2) was used to evaluate the quality of the included literature. The combined sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), and Diagnostic odds ratio (DOR) were pooled, and a comprehensive ROC curve analysis was performed. Statistical software StataSE 12.0 and Meta-Disc 1.4 were used for data analysis. Results A total of 8,536 articles were retrieved, and 9 articles that met all inclusion criteria were included in this meta-analysis. The meta-analysis results show that the combined sensitivity, specificity, PLR, NLR, DOR, and area under the SROC curve of c-TCD for the diagnose of PFO-RLS were 0.91 (95% CI, 0.88-0.93), 0.87 (95% CI: 0.84-0.91), 6.0 (95% CI, 2.78-12.96), 0.10 (95% CI, 0.06-0.18), 91.61 (95% CI, 26.55-316.10), and 0.9681, respectively; the corresponding values of c-TTE were 0.86 (95% CI, 0.84-0.89), 0.88 (95% CI, 0.84-0.91), 5.21 (95% CI, 2.55-10.63), 0.16 (95% CI, 0.09-0.31), 71.43 (95% CI, 22.85-223.23), and 0.9532. The ROC curve shows that c-TCD has slightly higher diagnostic value for PFO than c-TTE, but there is no significant statistical difference (Z = 0.622, p > 0.05). Deek funnel pattern showed no significant publication bias. Conclusion Both c-TCD and c-TTE have high diagnostic values for PFO-RLS. However, c-TCD has slightly higher sensitivity and lower specificity in diagnosing PFO-RLS compared to c-TTE.Systematic review registration: identifier [CRD42024544169].
Collapse
Affiliation(s)
| | | | | | - Mei-Fang Pan
- Department of Ultrasound, Xiangcheng People's Hospital, Suzhou, China
| |
Collapse
|
4
|
Cannata F, Stankowski K, Donia D, Figliozzi S, Fazzari F, Regazzoli D, Reimers B, Bragato RM, Pontone G, Trabattoni D, Colombo A, De Marco F, Mangieri A. Percutaneous suture-based patent foramen ovale closure: A state-of-the-art review. Trends Cardiovasc Med 2024; 34:404-413. [PMID: 37931791 DOI: 10.1016/j.tcm.2023.10.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 10/18/2023] [Accepted: 10/31/2023] [Indexed: 11/08/2023]
Abstract
Percutaneous closure of a patent foramen ovale (PFO), a common variation of interatrial septum anatomy, is a commonly performed procedure in the catheterization laboratory to reduce the risk of recurrent stroke in selected patients and to treat other PFO-related syndromes. In the last twenty years, disc-based devices have represented the armamentarium of the interventional cardiologist; recently, suture-based devices have become an attractive alternative, despite limited data regarding their long-term performance. The present review gives an overview of the current evidence regarding suture-based PFO closure, the device's characteristics, the echocardiographic evaluation of the PFO anatomy, and recommendations for patient selection. A detailed procedural guide is then provided, and potential complications and future developments in the field are discussed.
Collapse
Affiliation(s)
- Francesco Cannata
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini, 4, 20090 Pieve Emanuele, Milano, Italy; IRCCS Humanitas Research Hospital, Via Alessandro Manzoni, 56, 20089 Rozzano, Milano, Italy; Department of Perioperative Cardiology and Cardiovascular imaging, Centro Cardiologico Monzino IRCCS, Milan, Italy.
| | - Kamil Stankowski
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini, 4, 20090 Pieve Emanuele, Milano, Italy; IRCCS Humanitas Research Hospital, Via Alessandro Manzoni, 56, 20089 Rozzano, Milano, Italy
| | - Dario Donia
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini, 4, 20090 Pieve Emanuele, Milano, Italy; IRCCS Humanitas Research Hospital, Via Alessandro Manzoni, 56, 20089 Rozzano, Milano, Italy
| | - Stefano Figliozzi
- IRCCS Humanitas Research Hospital, Via Alessandro Manzoni, 56, 20089 Rozzano, Milano, Italy
| | - Fabio Fazzari
- Department of Perioperative Cardiology and Cardiovascular imaging, Centro Cardiologico Monzino IRCCS, Milan, Italy
| | - Damiano Regazzoli
- IRCCS Humanitas Research Hospital, Via Alessandro Manzoni, 56, 20089 Rozzano, Milano, Italy
| | - Bernhard Reimers
- IRCCS Humanitas Research Hospital, Via Alessandro Manzoni, 56, 20089 Rozzano, Milano, Italy
| | - Renato Maria Bragato
- IRCCS Humanitas Research Hospital, Via Alessandro Manzoni, 56, 20089 Rozzano, Milano, Italy
| | - Gianluca Pontone
- Department of Perioperative Cardiology and Cardiovascular imaging, Centro Cardiologico Monzino IRCCS, Milan, Italy; Department of Biomedical, Surgical and Dental Sciences, University of Milan, Milan, Italy
| | - Daniela Trabattoni
- Department of Interventional Cardiology, Centro Cardiologico Monzino IRCCS, Milan, Italy
| | - Antonio Colombo
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini, 4, 20090 Pieve Emanuele, Milano, Italy; IRCCS Humanitas Research Hospital, Via Alessandro Manzoni, 56, 20089 Rozzano, Milano, Italy
| | - Federico De Marco
- Department of Interventional Cardiology, Centro Cardiologico Monzino IRCCS, Milan, Italy
| | - Antonio Mangieri
- IRCCS Humanitas Research Hospital, Via Alessandro Manzoni, 56, 20089 Rozzano, Milano, Italy.
| |
Collapse
|
5
|
Kasner SE, Sondergaard L, Nakum M, Gomez Montero M, Hashim M, Landaas EJ. A matching-adjusted indirect comparison of results from REDUCE and RESPECT-two randomized trials on patent foramen ovale closure devices to prevent recurrent cryptogenic stroke. J Med Econ 2024; 27:337-343. [PMID: 38373018 DOI: 10.1080/13696998.2024.2320604] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/11/2024] [Accepted: 02/15/2024] [Indexed: 02/20/2024]
Abstract
AIMS Two randomized clinical trials, REDUCE and RESPECT, demonstrated that patent foramen ovale (PFO) closure in combination with antithrombotic therapy was more effective for the prevention of recurrent ischemic stroke compared with antithrombotic therapy alone. The aim of this study was to determine the relative efficacy and safety of the PFO closure devices used in REDUCE (HELEX and CARDIOFORM Septal Occluders) compared with the device used in RESPECT (Amplatzer PFO Occluder). METHODS An unanchored matching-adjusted indirect comparison (MAIC) of the PFO closure arms of the REDUCE and RESPECT trials was performed using patient-level data from REDUCE weighted to match baseline characteristics from RESPECT. Comparisons of the following outcomes were made between the devices assessed in the trials: risk of recurrent ischemic stroke; recurrent ischemic stroke one year after randomization; any serious adverse event (SAE) related to the procedure or device; and atrial fibrillation or atrial flutter as an SAE related to the procedure or device. RESULTS After conducting the MAIC, baseline characteristics were well-matched between the two trials. Compared to RESPECT, PFO closure using the devices from REDUCE resulted in a hazard ratio of 0.46 (95% confidence interval [CI] 0.15-1.43; p = 0.17) for the risk of recurrent stroke. For the recurrence of stroke after one year, SAE related to the procedure or device, and atrial fibrillation or atrial flutter as SAE related to the procedure or device, the MAIC resulted in a rate difference of -0.68 (95%CI -2.06 to 0.70; p = .34), -1.29 (95%CI -3.82 to 1.25; p = .32), and -0.19 (95%CI -1.16 to 0.78; p = .71), respectively. These findings were consistent across scenario analyses. CONCLUSIONS This MAIC analysis found no statistically significant differences in efficacy and safety outcomes between PFO closure with the HELEX and CARDIOFORM Septal Occluders versus the Amplatzer PFO Occluder, as used in the REDUCE and RESPECT trials.
Collapse
Affiliation(s)
- Scott E Kasner
- Department of Neurology, University of Pennsylvania, Philadelphia, PA, USA
| | | | | | | | | | | |
Collapse
|
6
|
Song JK. Pearls and Pitfalls in the Transesophageal Echocardiographic Diagnosis of Patent Foramen Ovale. J Am Soc Echocardiogr 2023; 36:895-905.e3. [PMID: 37196905 DOI: 10.1016/j.echo.2023.05.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 05/01/2023] [Accepted: 05/02/2023] [Indexed: 05/19/2023]
Abstract
Large randomized controlled trials have shown the benefits of percutaneous closure of patent foramen ovale (PFO) in patients with cryptogenic stroke and PFO. Recent studies have highlighted the clinical significance and prognostic implication of various anatomical features of PFO and the adjacent atrial septum, such as atrial septal aneurysm (ASA), PFO size, large shunt, and hypermobility. Transthoracic echocardiography with contrast study is used for the indirect diagnosis of PFO, as it reveals the passage of the contrast into the left atrium. In contrast, transesophageal echocardiography (TEE) offers a direct demonstration of PFO by measuring its size using the maximum separation distance between the septum primum and septum secundum. Furthermore, TEE enables the acquisition of detailed anatomical features of the adjacent atrial septum including ASA, hypermobility, and PFO tunnel length, which carry significant prognostic implications. Transesophageal echocardiography also facilitates the diagnosis of pulmonary arteriovenous malformation, a relatively rare cause of paradoxical embolism. This review provides evidence for supporting TEE as a useful screening test for patients with cryptogenic stroke to identify suitable candidates for percutaneous device closure of PFO. Additionally, cardiac imaging specialists with proficiency in comprehensive TEE examination should be part of the heart-brain team for proper evaluation of and decision-making in patients with cryptogenic stroke.
Collapse
Affiliation(s)
- Jae-Kwan Song
- Professor of Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea.
| |
Collapse
|
7
|
Datta T, Ruggiero N, Peters A, Pender A, Vishnevsky A, Mehrotra P. Three-dimensional Transesophageal Echocardiography for Transcatheter Patent Foramen Ovale Closure: Standardizing Anatomic Nomenclature and Novel Sizing Concepts. CASE (PHILADELPHIA, PA.) 2022; 7:14-20. [PMID: 36704482 PMCID: PMC9871352 DOI: 10.1016/j.case.2022.10.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/02/2022]
Abstract
Terminology for PFO tunnel sizing remains unstandardized. Device size selection for transcatheter PFO closure is highly variable. Tunnel width measurements may be a better descriptor of PFO size. Wire sizing may be a useful technique for assessment of PFO dimensions. PFO sizing strategies based on tunnel width need to be better studied.
Collapse
Affiliation(s)
| | | | | | | | | | - Praveen Mehrotra
- Correspondence: Praveen Mehrotra, MD, Associate Professor of Medicine, Division of Cardiology, Sidney Kimmel Medical College, Thomas Jefferson University, 925 Chestnut Street, Mezzanine Level, Philadelphia, PA 19107
| |
Collapse
|
8
|
Chino S, Mochizuki Y, Mizuma K, Ichikawa S, Miyazaki H, Hachiya R, Toyosaki E, Fukuoka H, Ono K, Shinke T. Reply to 'patent foramen ovale device closure for patients with stroke and high-risk PFO morphology'. Heart Vessels 2022; 38:871-872. [PMID: 35999318 DOI: 10.1007/s00380-022-02157-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/29/2022] [Accepted: 08/17/2022] [Indexed: 11/04/2022]
Affiliation(s)
- Saori Chino
- Division of Cardiovascular Medicine, Department of Internal Medicine, Showa University, Tokyo, Japan
| | - Yasuhide Mochizuki
- Division of Cardiovascular Medicine, Department of Internal Medicine, Showa University, Tokyo, Japan.
| | - Keita Mizuma
- Division of Neurology, Department of Internal Medicine, Showa University, Tokyo, Japan
| | - Saaya Ichikawa
- Division of Cardiovascular Medicine, Department of Internal Medicine, Showa University, Tokyo, Japan
| | - Haruka Miyazaki
- Division of Cardiovascular Medicine, Department of Internal Medicine, Showa University, Tokyo, Japan
| | - Rumi Hachiya
- Division of Cardiovascular Medicine, Department of Internal Medicine, Showa University, Tokyo, Japan
| | - Eiji Toyosaki
- Division of Cardiovascular Medicine, Department of Internal Medicine, Showa University, Tokyo, Japan
| | - Hiroto Fukuoka
- Division of Cardiovascular Medicine, Department of Internal Medicine, Showa University, Tokyo, Japan
| | - Kenjiro Ono
- Division of Neurology, Department of Internal Medicine, Showa University, Tokyo, Japan
| | - Toshiro Shinke
- Division of Cardiovascular Medicine, Department of Internal Medicine, Showa University, Tokyo, Japan
| |
Collapse
|
9
|
To the Editor,. Clin Neurol Neurosurg 2022; 221:107308. [DOI: 10.1016/j.clineuro.2022.107308] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 05/22/2022] [Accepted: 05/25/2022] [Indexed: 11/03/2022]
|
10
|
Dabigatran versus aspirin for stroke prevention after cryptogenic stroke with patent foramen ovale: A prospective study. Clin Neurol Neurosurg 2022; 215:107189. [DOI: 10.1016/j.clineuro.2022.107189] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2021] [Revised: 02/02/2022] [Accepted: 02/23/2022] [Indexed: 11/22/2022]
|
11
|
Dodson BK, Major CK, Grant M, Yoo BS, Goodman BM. Platypnea Orthodeoxia Due to a Patent Foramen Ovale and Intrapulmonary Shunting After Severe COVID-19 Pneumonia. AMERICAN JOURNAL OF CASE REPORTS 2021; 22:e933975. [PMID: 34697281 PMCID: PMC8559663 DOI: 10.12659/ajcr.933975] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Revised: 09/25/2021] [Accepted: 09/10/2021] [Indexed: 02/05/2023]
Abstract
BACKGROUND Platypnea orthodeoxia syndrome (POS) presents with positional dyspnea and hypoxemia defined as arterial desaturation of at least 5% or a drop in PaO2 of at least 4 mmHg. Causes of POS include a variety of cardiopulmonary etiologies and has been reported in patients recovering from severe COVID-19 pneumonia. However, clinical presentation and outcomes in a patient with multiple interrelated mechanisms of shunting has not been documented. CASE REPORT An 85-year-old man hospitalized for hypertensive emergency and severe COVID-19 pneumonia was diagnosed with platypnea orthodeoxia on day 28 of illness. During his disease course, the patient required supplemental oxygen by high-flow nasal cannula but never required invasive mechanical ventilation. Chest imaging revealed evolving mixed consolidation and ground-glass opacities with a patchy and diffuse distribution, involving most of the left lung. Echocardiography was ordered to evaluate for intracardiac shunt, which revealed a patent foramen ovale. Closure of the patent foramen ovale was not pursued. Management included graded progression to standing and supplemental oxygen increases when upright. The patient was discharged to a skilled nursing facility and his positional oxygen requirement resolved on approximately day 78. CONCLUSIONS The present case highlights the multiple interrelated mechanisms of shunting in patients with COVID-related lung disease and a patent foramen ovale. Eight prior cases of POS after COVID-19 pneumonia have been reported to date but none with a known patent foramen ovale. In patients with persistent positional oxygen requirements at follow-up, quantifying shunt fraction over time through multiple modalities can guide treatment decisions.
Collapse
Affiliation(s)
- Blair K. Dodson
- Department of Internal Medicine, Eastern Virginia Medical School, Norfolk, VA, USA
| | - C. Kendall Major
- Department of Medicine, Hospital of the University of Pennsylvania, Philadelphia, PA, USA
| | - Maxwell Grant
- Department of Internal Medicine, Eastern Virginia Medical School, Norfolk, VA, USA
| | - Byung Soo Yoo
- Department of Internal Medicine, Eastern Virginia Medical School, Norfolk, VA, USA
| | - B. Mitchell Goodman
- Department of Internal Medicine, Eastern Virginia Medical School, Norfolk, VA, USA
| |
Collapse
|
12
|
Kumar P, Mojadidi MK, Tobis JM. Proper Sizing of Patent Foramen Ovale and Grading of Residual Right-to-Left Shunt. JACC Cardiovasc Interv 2021; 14:106. [PMID: 33413856 DOI: 10.1016/j.jcin.2020.10.040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Accepted: 10/27/2020] [Indexed: 11/16/2022]
|
13
|
The Efficacy of Contrast Transthoracic Echocardiography and Contrast Transcranial Doppler for the Detection of Patent Foramen Ovale Related to Cryptogenic Stroke. BIOMED RESEARCH INTERNATIONAL 2020; 2020:1513409. [PMID: 32566656 PMCID: PMC7275210 DOI: 10.1155/2020/1513409] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/17/2020] [Accepted: 04/11/2020] [Indexed: 11/18/2022]
Abstract
Background Patent foramen ovale (PFO) has been linked to the pathophysiology of cryptogenic stroke. Contrast transesophageal echocardiography (cTEE) is the current gold standard for PFO diagnosis, but it has the disadvantage of being semi-invasive and does not exempt from risks. As a diagnostic test, the efficacy of contrast transthoracic echocardiography (cTTE) and contrast transcranial Doppler (cTCD) is controversial. This study is aimed at investigating the efficacy of cTTE and cTCD versus cTEE in PFO detection, exploring a more cost-effective and reliable method for the diagnosis of PFO related to cryptogenic stroke. Methods From August 2019 to January 2020, a total of 213 patients with suspected PFO were included in our study. All patients underwent cTEE, cTCD, and cTTE examinations. cTTE3 was named for using a cutoff of 3 beats to detect PFO during cTTE, and cTTE5 represented a cutoff of 5 beats. A cutoff of cTCD grade III was named cTCD III. A cutoff of grade IV was named cTCD IV. cTTE3+cTCD IV was used for the combination of a cutoff of 3 beats during cTTE with grade IV of cTCD. cTTE5+cTCD III combined a cutoff of 5 beats during cTTE with cTCD grade III. Taking cTEE as the gold standard, we compared the sensitivity, specificity, negative likelihood ratio (-LR), and misdiagnosis rate for PFO detection among the above methods. Results A total of 161 of 213 (76%) patients had PFO confirmed by cTEE. With the spontaneous Valsalva maneuver, the sensitivity, specificity, negative likelihood ratio (-LR), and misdiagnosis rate of cTTE3 in PFO diagnosis were 60%, 90%, 44%, and 10%, respectively, and those for cTTE5 were 76%, 78%, 31% and 22%, respectively. The sensitivity, specificity, negative likelihood ratio (-LR), and misdiagnosis rate of cTCD III were 80%, 71%, 29%, and 29%, respectively, while those for cTCD IV were 55%, 90%, 49%, and 10%, respectively. When cTTE and cTCD were combined to diagnose PFO, the specificity and misdiagnosis rate were significantly improved, especially cTTE3+cTCD IV, with 100% specificity and a misdiagnosis rate of 0. Conclusion cTTE or cTCD can be used for preliminary PFO related to cryptogenic stroke findings. The combination of the two methods can improve the specificity of PFO diagnosis, especially using the cutoff of cTTE3+cTCD IV.
Collapse
|