1
|
Yang YX, Liu XM, Fu Y, Li C, Wang HJ, Xu L, Xia K, Zhang ZY, Zhong JC, Chen ML, Su PX, Wang LF. Comparisons of different new-generation transcatheter aortic valve implantation devices for patients with severe aortic stenosis: a systematic review and network meta-analysis. Int J Surg 2023; 109:2414-2426. [PMID: 37161443 PMCID: PMC10442113 DOI: 10.1097/js9.0000000000000456] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2022] [Accepted: 05/01/2023] [Indexed: 05/11/2023]
Abstract
BACKGROUND Whether there are differences among the new-generation transcatheter aortic valve implantation (TAVI) devices for patients with aortic stenosis remains unclear. The aim of the study was to compare the efficiency and safety of different new-generation TAVI devices for patients with aortic stenosis. MATERIALS AND METHODS A comprehensive search of PubMed, Embase and Web of Science from their inception to 1 February 2022. Randomized clinical trials and observational studies that compared two or more different TAVI devices were enroled. Pairwise meta-analysis and frequentist network meta-analysis were conducted to pool the outcome estimates of interest. RESULTS A total of 79 studies were finally included. According to the surface under the cumulative ranking, the top two ranked valves for lower rates of events were as follows: direct flow medical (DFM) (4.6%) and Lotus (48.8%) for lower rate of device success; Sapien 3 (16.8%) and DFM (19.7%) for lower mortality; DFM (8.6%) and Sapien 3 (25.5%) for lower rates of stroke; Evolut (27.6%) and DFM (35.8%) for lower rates of major and life-threatening bleeding; Portico (22.6%) and Sapien 3 (41.9%) for lower rates of acute kidney injury; Acurate (8.6%) and DFM (13.2%) for lower rates of permanent pacemaker implantation; Lotus (0.3%) and Sapien 3 (22.7%) for lower rates of paravalvular leak; Evolut (1.4%) and Portico (29.1%) for lower rates of mean aortic valve gradients. CONCLUSIONS The findings of the present study suggested that the device success rates were comparable among these new-generation valves except for DFM. After excluding DFM, Sapien 3 might be the best effective for decreased mortality and stroke; Lotus might be the best effective for decreased paravalvular leak; Evolut might be the best effective for decreased major and life-threatening bleeding and mean aortic valve gradients; Acurate and Portico might be the best effective for decreased permanent pacemaker implantation and acute kidney injury, respectively.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | | | | | - Pi-Xiong Su
- Heart Center and Beijing Key Laboratory of Hypertension, Beijing Chaoyang Hospital, Capital Medical University, Chaoyang District, Beijing, China
| | | |
Collapse
|
2
|
Koliastasis L, Doundoulakis I, Kokkinidis DG, Milkas A, Kostopoulos G, Drakopoulou M, Latsios G, Synetos A, Benetos G, Lampropoulos K, Economou F, Tsioufis K, Toutouzas K. Study Level Meta-Analysis of Transcatheter Aortic Valve Implantation With the ACURATE neo Self-Expanding Transcatheter Heart Valve. Cardiol Rev 2023; 31:108-114. [PMID: 35358104 DOI: 10.1097/crd.0000000000000453] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
The ACURATE neo transcatheter aortic valve is a self-expanding device. Several studies have investigated safety and efficacy, but meta-analysis and pooled data are lacking. We aimed to provide a comprehensive systematic review and meta-analysis on the clinical outcomes of transcatheter aortic valve implantation with the ACURATE neo valve. A systematic literature search for eligible records was conducted. The primary endpoint was device success as designated by Valve Academic Research Consortium-2 criteria. The secondary endpoints (time frame: 30 days) were all-cause mortality, stroke, myocardial infarction, need for new permanent pacemaker, major vascular complications, major bleeding, acute kidney injury stage II or III, and paravalvular regurgitation grade moderate or severe (II or III). Our search yielded a total of 355 records, 20 of those (n = 5858 ACURATE neo receivers) were included in our meta-analysis. Device success was achieved in 94.5% (95% confidence interval [CI], 91.4-96.5%) of the patients. The 30-day all-cause mortality incidence proportion was 1.8% (95% CI, 1.3-2.4%). New pacemaker implantation was required in 7.7% (95% CI, 6.4-9.2%) of the patients, stroke occurred in 1.9% (95% CI, 1.6-2.3%), myocardial infarction in 0.5% (95% CI, 0.3-0.7%), major bleeding in 5.0% (95% CI, 3.9-6.5%), major vascular complication in 5.6% (95% CI, 4.0-7.8%), acute kidney injury stage ≥2 in 2.5% (95% CI, 1.8-3.4%), and paravalvular leak grade ≥moderate was observed in 4.3% (95% CI, 3.0-6.2%). Balloon predilatation and postdilatation incidence was 93.9% (95% CI, 87.0-97.3%) and 43.2% (95% CI, 37.9-48.6%), respectively. ACURATE neo appears to be safe and effective in our analysis with high device success incidence, low mortality, and low new pacemaker implantations.
Collapse
Affiliation(s)
- Leonidas Koliastasis
- From the First Department of Cardiology, National and Kapodistrian University, "Hippokration" Hospital, Athens, Greece
- Athens Naval and Veterans Hospital, Athens, Greece
| | - Ioannis Doundoulakis
- From the First Department of Cardiology, National and Kapodistrian University, "Hippokration" Hospital, Athens, Greece
- Department of Cardiology, 424 General Military Training Hospital, Thessaloniki, Greece
| | - Damianos G Kokkinidis
- Section of Cardiovascular Medicine, Yale University School of Medicine, Yale New Haven Hospital, New Haven, CT
| | | | - Georgios Kostopoulos
- Department of Endocrinology, 424 General Military Training Hospital, Thessaloniki, Greece
| | - Maria Drakopoulou
- From the First Department of Cardiology, National and Kapodistrian University, "Hippokration" Hospital, Athens, Greece
| | - Georgios Latsios
- From the First Department of Cardiology, National and Kapodistrian University, "Hippokration" Hospital, Athens, Greece
| | - Andreas Synetos
- From the First Department of Cardiology, National and Kapodistrian University, "Hippokration" Hospital, Athens, Greece
| | - Georgios Benetos
- From the First Department of Cardiology, National and Kapodistrian University, "Hippokration" Hospital, Athens, Greece
| | | | - Fotios Economou
- Department of Cardiology, 424 General Military Training Hospital, Thessaloniki, Greece
| | - Konstantinos Tsioufis
- From the First Department of Cardiology, National and Kapodistrian University, "Hippokration" Hospital, Athens, Greece
| | - Konstantinos Toutouzas
- From the First Department of Cardiology, National and Kapodistrian University, "Hippokration" Hospital, Athens, Greece
| |
Collapse
|
3
|
Kooistra NH, Intan-Goey VMP, Ziviello F, Leenders GE, Kraaijeveld AO, Doevendans PA, Van Mieghem NM, Voskuil M, Stella PR. Comparison of the Sapien 3 versus the ACURATE neo valve system: A propensity score analysis. Catheter Cardiovasc Interv 2020; 97:E597-E606. [PMID: 32886869 PMCID: PMC7984444 DOI: 10.1002/ccd.29240] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/23/2019] [Revised: 07/31/2020] [Accepted: 08/17/2020] [Indexed: 11/30/2022]
Abstract
Objectives To compare the outcomes of transfemoral ACURATE neo (NEO) and Sapien 3 (S3) patients in terms of device success and clinical safety outcomes using a propensity score analysis. Background Differences in clinical outcomes between the latest‐generation balloon‐expandable S3 and self‐expanding NEO in a “real‐world transfemoral TAVI population” are still unclear. Methods We compared up to 6 months clinical outcomes using a propensity score analysis (inverse probability of treatment weighting [IPTW]) to account for differences in baseline characteristics. Results A total of 345 patients underwent transfemoral transcatheter aortic valve implantation (TAVI) with either NEO or S3 at two centers in the Netherlands. Composite device success and early safety endpoints were comparable between NEO and S3 (Device success: IPTW‐adjusted OR: 0.35 [95% CI: 0.12–1.18], and early safety: IPTW‐adjusted OR: 0.51 [95% CI: 0.19–1.38]). Six‐months mortality was 5.3 versus 3.6%, stroke was 2.8 versus 3.3%, and pacemaker rate was 6.1 versus 8.6%, respectively with p = NS. Mean aortic gradient was lower in the NEO group (5.72 ± 2.47 vs. 9.05 ± 3.48; p = <.001), with a comparable rate of moderate or severe paravalvular leak (0 versus 2.1%; p = NS). Conclusions Device success and clinical safety outcomes were comparable for both valves. Up to 6‐months follow‐up clinical outcomes and mortality rate remained excellent. Mean aortic gradient was lower after ACURATE neo implantation.
Collapse
Affiliation(s)
- Nynke H Kooistra
- Department of Cardiology, University Medical Centre Utrecht, Utrecht, The Netherlands
| | - Valent M P Intan-Goey
- Department of Cardiology, University Medical Centre Utrecht, Utrecht, The Netherlands
| | - Francesca Ziviello
- Department of Cardiology, Thoraxcenter, Erasmus Medical Centre, Rotterdam, the Netherlands
| | - Geert E Leenders
- Department of Cardiology, University Medical Centre Utrecht, Utrecht, The Netherlands
| | - Adriaan O Kraaijeveld
- Department of Cardiology, University Medical Centre Utrecht, Utrecht, The Netherlands
| | - Pieter A Doevendans
- Department of Cardiology, University Medical Centre Utrecht, Utrecht, The Netherlands.,Netherlands Heart Institute, Utrecht, The Netherlands.,Central Military Hospital, Utrecht, The Netherlands
| | - Nicolas M Van Mieghem
- Department of Cardiology, Thoraxcenter, Erasmus Medical Centre, Rotterdam, the Netherlands
| | - Michiel Voskuil
- Department of Cardiology, University Medical Centre Utrecht, Utrecht, The Netherlands
| | - Pieter R Stella
- Department of Cardiology, University Medical Centre Utrecht, Utrecht, The Netherlands
| |
Collapse
|