1
|
Travieso A, Toggweiler S, Montarello N, Renker M, Tirado-Conte G, Loretz L, Charitos EI, Kim WK, De Backer O. Commissural alignment and the ACURATE neo2 transcatheter aortic valve: Impact on valve performance. Catheter Cardiovasc Interv 2024; 104:115-124. [PMID: 38764320 DOI: 10.1002/ccd.31089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Revised: 02/26/2024] [Accepted: 05/08/2024] [Indexed: 05/21/2024]
Abstract
BACKGROUND Transcatheter aortic valve replacement (TAVR) is increasingly being used to treat severe aortic stenosis in younger patients. Accordingly, lifetime management regarding future reintervention and coronary access is a concern. AIMS To assess the impact of commissural alignment on ACURATE neo2 transcatheter aortic valve (TAV) performance. METHODS COMALIGN-neo2 was an observational, retrospective study enrolling consecutive TAVR patients treated with the ACURATE neo2 (October 2021 to October 2022). The degree of commissural (mis)-alignment (CMA) with the native aortic valve commissures was determined and transvalvular gradient, effective orifice area, patient-prosthesis mismatch (PPM), and aortic regurgitation (AR) were assessed. RESULTS Among 825 patients, the mean age was 80.7 years and 42% were female. Commissural alignment was achieved in 60% of cases; mild (26%), moderate (9%), and severe misalignment (5%) were found less often. Severe PPM occurred more frequently in patients with severe CMA (14.7%) compared to aligned valves (p = 0.034). By multivariate analysis, severe CMA (odds ratio [OR]: 3.12, 95% confidence interval [CI] [1.09-8.90]; p = 0.033) and lack of postdilatation (OR: 3.85, [1.33-11.1]; p = 0.012) were associated with severe PPM. Higher rates of ≥mild AR (51.4%) were found in TAVs implanted with severe CMA compared to aligned (34.3%), mildly (38.1%) or moderately (36.0%) misaligned TAVs (p = 0.030). Multivariate analysis identified severe CMA (OR: 2.05, [1.05-4.02]; p = 0.037) to be an independent predictor of ≥mild AR. CONCLUSIONS COMALIGN-neo2 is the largest study to date assessing the impact of commissural alignment on acute TAV performance. Severe CMA with the ACURATE neo2 platform was associated with worse valve hemodynamics and increased risk for mild AR.
Collapse
Affiliation(s)
| | | | | | - Matthias Renker
- Department of Cardiology, Kerckhoff Heart Center, Bad Nauheim, Germany
- Department of Cardiac Surgery, Kerckhoff Heart Center, Bad Nauheim, Germany
- DZHK (German Center for Cardiovascular Research), Site Rhein-Main, Bad Nauheim, Germany
| | | | - Lucca Loretz
- Heart Center Lucerne, Lucerner Kantonsspital, Lucerne, Switzerland
| | | | - Won-Keun Kim
- Department of Cardiology, Kerckhoff Heart Center, Bad Nauheim, Germany
- Department of Cardiac Surgery, Kerckhoff Heart Center, Bad Nauheim, Germany
- DZHK (German Center for Cardiovascular Research), Site Rhein-Main, Bad Nauheim, Germany
- Department of Cardiology, Justus Liebig University of Giessen and Marburg, Giessen, Germany
| | - Ole De Backer
- The Heart Center, Rigshospitalet, Copenhagen, Denmark
| |
Collapse
|
2
|
Meduri CU, Rück A, Linder R, Verouhis D, Settergren M, Sorajja A, Daher D, Saleh N. Commissural Alignment With ACURATE neo2 Valve in an Unselected Population. JACC Cardiovasc Interv 2023; 16:670-677. [PMID: 36990556 DOI: 10.1016/j.jcin.2023.01.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Revised: 12/08/2022] [Accepted: 01/10/2023] [Indexed: 03/31/2023]
Abstract
BACKGROUND Commissural alignment has become an important topic in transcatheter aortic valve replacement (TAVR) because it may improve coronary access, facilitate future valve procedures, and possibly improve valve durability. The efficacy of commissural alignment with ACURATE neo2 has not yet been shown in a large population. OBJECTIVES The authors sought to determine the feasibility and success of attempting commissural alignment in an unselected TAVR population treated with the ACURATE neo2 prosthetic heart valve. METHODS A total of 170 consecutive patients underwent TAVR with a dedicated implantation technique to align the TAVR valve to the native valve. Using right-left overlap and 3-cusp views, valve orientation was adjusted by rotation of the unexpanded valve at the level of the aortic root. Effectiveness was assessed postprocedure as the degree of misalignment determined by analyzing fluoroscopic valve orientation to corresponding cusp orientation on preprocedural computed tomography. Safety endpoints included mortality, stroke/transient ischemic attack, and additional complications through 30 days. RESULTS Of 170 patients, 167 (98.2%) could be analyzed for alignment, and all 170, for safety outcomes. Most patients (97%) had successful alignment (≤ mild misalignment), with 80% with commissural alignment, while the degrees of misalignment were 17% mild, 1.2% moderate, 1.8% severe. CONCLUSIONS In this large evaluation of a commissural alignment technique, alignment was achieved in nearly all patients without safety concerns or impact to procedure duration. Commissural alignment appears effective and safe across all patients with this novel technique.
Collapse
Affiliation(s)
| | - Andreas Rück
- Karolinska University Hospital, Department of Cardiology, Stockholm, Sweden. https://twitter.com/AndreasRck2
| | - Rickard Linder
- Karolinska University Hospital, Department of Cardiology, Stockholm, Sweden
| | - Dinos Verouhis
- Karolinska University Hospital, Department of Cardiology, Stockholm, Sweden
| | - Magnus Settergren
- Karolinska University Hospital, Department of Cardiology, Stockholm, Sweden
| | - Amalin Sorajja
- Karolinska University Hospital, Department of Cardiology, Stockholm, Sweden
| | - Daniel Daher
- Karolinska University Hospital, Department of Cardiology, Stockholm, Sweden
| | - Nawzad Saleh
- Karolinska University Hospital, Department of Cardiology, Stockholm, Sweden
| |
Collapse
|
3
|
Gada H, Salem M, Vora AN. Commissural Alignment During TAVR: Flush Ports and Goal Posts. JACC Cardiovasc Interv 2023; 16:678-680. [PMID: 36990557 DOI: 10.1016/j.jcin.2023.02.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Accepted: 02/14/2023] [Indexed: 03/31/2023]
Affiliation(s)
- Hemal Gada
- Heart and Vascular Institute, University of Pittsburgh Medical Center, Harrisburg, Pennsylvania, USA.
| | - Mahmoud Salem
- Heart and Vascular Institute, University of Pittsburgh Medical Center, Harrisburg, Pennsylvania, USA
| | - Amit N Vora
- Heart and Vascular Institute, University of Pittsburgh Medical Center, Harrisburg, Pennsylvania, USA
| |
Collapse
|
4
|
Tarantini G, Fabris T, Nai Fovino L, Cardaioli F, Pergola V, Montonati C, Rodinò G, Cabrelle G, Massussi M, Scotti A, Zuccarelli V, Sciarretta T, Masiero G, Gregori D, Napodano M, Fraccaro C, Continisio S, Iliceto S. Definition of trAnscatheter heart Valve orIeNtation in biCuspId aortic valve: The DA VINCI pilot study. Front Cardiovasc Med 2022; 9:1056496. [PMID: 36578836 PMCID: PMC9790995 DOI: 10.3389/fcvm.2022.1056496] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Accepted: 11/16/2022] [Indexed: 12/15/2022] Open
Abstract
Objectives To assess the impact of conventional transcatheter heart valve (THV) commissural alignment techniques on THV/coronary overlap and coronary access (CA) after transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BAV). Background Specific Evolut Pro/Pro + and Acurate Neo2 THV orientations are associated with reduced neo-commissural overlap with coronary ostia in tricuspid aortic anatomy. Whether standard orientation techniques are effective also in the setting of BAV anatomy has not been studied. Methods The DA VINCI (Definition of trAnscatheter aortic Valve orIeNtation in biCuspId aortic valve) pilot study is a prospective registry enrolling consecutive patients with severe BAV stenosis undergoing TAVR with last generation supra-annular tall-frame THVs implanted with a cusp overlap view-based commissural alignment. Patients underwent pre- and post-TAVR computed tomography (CT) and coronary angiography. The study endpoint was the rate of favorable THV/coronary overlap, defined as an angle > 40° between the THV commissural post and coronary ostia. Other endpoints were the rates of successful THV alignment with respect to the raphe and of selective CA after TAVR. Moreover, different virtual THV alignment models were tested to identify which one would produce the lower degree of THV/coronary overlap. Results Thirty-four patients with type 1 BAV with right-left raphe undergoing TAVR (23 with Evolut Pro/Pro + and 11 with Acurate Neo2) were included. At pre-TAVR CT, moderate/severe cusp asymmetry was found in 50% of patients, severe coronary ostia eccentricity was observed in 47.1% for the RCA vs. 8.8% for the LCA (P < 0.007). Correct TVH orientation was achieved in 29 cases. At post-TAVR CT, optimal THV alignment/mild misalignment to the raphe was observed in 86.2%, but a moderate/severe overlap with the coronaries was seen in 13.7% for the RCA and 44.8% for the LCA (P = 0.019). After TAVR, selective RCA cannulation was possible in 82.8% vs. 75.9% for the LCA (P = 0.74), while combined selective CA of both coronaries was possible in less than two-thirds of the patients. Virtual THV alignment in the coronary ostia overlap view assuming a hypothetical circular THV expansion would produce an optimal THV/coronary overlap in almost 90% of cases. Conclusion Given cusp asymmetry and coronary ostia eccentricity of BAV combined with potential THV asymmetrical expansion, conventional commissural alignment techniques are associated with higher rates of THV misalignment and of moderate/severe neo-commissure overlap with the coronary ostia as compared to tricuspid aortic stenosis, resulting in lower rates of selective CA after TAVR. A modified THV orientation technique based on the coronary ostia overlap view might be preferable in BAV patients.
Collapse
Affiliation(s)
- Giuseppe Tarantini
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy,*Correspondence: Giuseppe Tarantini,
| | - Tommaso Fabris
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy
| | - Luca Nai Fovino
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy
| | - Francesco Cardaioli
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy
| | - Valeria Pergola
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy
| | - Carolina Montonati
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy
| | - Giulio Rodinò
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy
| | - Giulio Cabrelle
- Department of Medicine—DIMED, University of Padua, Padua, Italy
| | - Mauro Massussi
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy,Cardiac Catheterization Laboratory and Cardiology, ASST Spedali Civili di Brescia, Department of Medical and Surgical Specialties, Radiological Sciences, and Public Health, University of Brescia, Brescia, Italy
| | - Andrea Scotti
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy,Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY, United States
| | - Vittorio Zuccarelli
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy
| | - Tommaso Sciarretta
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy
| | - Giulia Masiero
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy
| | - Dario Gregori
- Unit of Biostatistics, Epidemiology and Public Health, University of Padua, Padua, Italy
| | - Massimo Napodano
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy
| | - Chiara Fraccaro
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy
| | - Saverio Continisio
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy
| | - Sabino Iliceto
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy
| |
Collapse
|
5
|
Khalid AM, O'Sullivan CJ. Commissural alignment in transcatheter aortic valve replacement: A literature review. Front Cardiovasc Med 2022; 9:938653. [PMID: 36017101 PMCID: PMC9396239 DOI: 10.3389/fcvm.2022.938653] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2022] [Accepted: 07/18/2022] [Indexed: 11/29/2022] Open
Abstract
Introduction Transcatheter aortic valve replacement (TAVR) is a minimally invasive procedure to replace a diseased and faulty aortic valve in patients with severe aortic stenosis. As TAVR gains popularity among lower-risk younger patients with a longer life expectancy; there is a need to investigate the long-term shortcomings and limitations of the procedure for this patient group. One such shortcoming is that commissural alignment of transcatheter heart valves (THV) appears to be random; meaning that the THV neo-commissures can misalign with the native commissures of the aortic valve during deployment or self-expansion. Objectives Identify techniques and procedures used to obtain commissural alignment in TAVR. Evaluate the effectiveness of these procedures in terms of the degree of commissural alignment. Analyse the impact of commissural alignment on coronary filling and re-access. Methods Two electronic online databases were searched to identify existing literature relevant to the aim and objectives of this review: EBSCOhost and PubMed. After search filters were applied and duplicates removed; a total of 64 articles from both databases were screened against the inclusion/exclusion criteria. This resulted in a total of thirteen articles which met the objectives of this review and thus; were included. Results All studies focused on a patient centered approach involving pre-TAVR computed tomography to obtain commissural alignment. Other studies modified this approach and combined techniques. All studies that implemented a technique to reduce commissural misalignment were significantly successful in obtaining commissural alignment when compared to a study in which alignment was random when no technique was implemented. Severe coronary overlapping in commissural aligned heart valves was relatively low compared to severe coronary overlapping when no technique was implemented. Conclusions An increase in optimal commissural alignment via introduction of an alignment technique may seem attractive; however; the categorization of commissural alignment is arbitrary and does not accurately reflect real life clinical implications. Further research is needed to determine whether a routine procedure to achieve commissural alignment is necessary in low-risk younger patients undergoing TAVR.
Collapse
|
6
|
Buono A, Morello A, Pero G, Corcione N, Bettari L, Saccocci M, Villa E, Biondi-Zoccai G, Giordano A, Maffeo D. Commissural Alignment With New-Generation Self-Expanding Transcatheter Heart Valves During Aortic Replacement. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2022; 40S:139-143. [PMID: 34362686 DOI: 10.1016/j.carrev.2021.07.027] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Revised: 07/22/2021] [Accepted: 07/26/2021] [Indexed: 02/05/2023]
Abstract
Preserving coronary artery access is a crucial goal during transcatheter aortic valve replacement (TAVR) procedures, especially in case of self-expandable transcatheter heart valve (SE-THV) implantation. In this light, a proper commissural alignment is needed to avoid the risk of coronary obstruction and to permit easy vessels re-cannulation for diagnostic and interventional purposes. New-generation SE-THVs have been furnished of different markers, able to guide operators to perform a correct commissural alignment. In this case series, we describe key procedural aspects of commissural alignment for the different available SE-THVs, providing a step-by-step tutorial for each device. Lastly, we illustrate a commissural alignment in a contrast-zero TAVR.
Collapse
Affiliation(s)
- Andrea Buono
- Interventional Cardiology Unit, Cardiovascular Department, Fondazione Poliambulanza Istituto Ospedaliero, Brescia, Italy.
| | - Alberto Morello
- Unità Operativa di Interventistica Cardiovascolare, Pineta Grande Hospital, Via Domitiana km 30.00, 81030 Castel Volturno, Italy
| | - Gaetano Pero
- Interventional Cardiology Unit, Cardiovascular Department, Fondazione Poliambulanza Istituto Ospedaliero, Brescia, Italy
| | - Nicola Corcione
- Unità Operativa di Interventistica Cardiovascolare, Pineta Grande Hospital, Via Domitiana km 30.00, 81030 Castel Volturno, Italy
| | - Luca Bettari
- Interventional Cardiology Unit, Cardiovascular Department, Fondazione Poliambulanza Istituto Ospedaliero, Brescia, Italy
| | - Matteo Saccocci
- Department of Cardiothoracic Surgery, Fondazione Poliambulanza Istituto Ospedaliero, Brescia, Italy
| | - Emmanuel Villa
- Department of Cardiothoracic Surgery, Fondazione Poliambulanza Istituto Ospedaliero, Brescia, Italy
| | - Giuseppe Biondi-Zoccai
- Department of Medical-Surgical Sciences and Biotechnologies, Sapienza University of Rome, Latina, Italy; Mediterranea Cardiocentro, Napoli, Italy
| | - Arturo Giordano
- Unità Operativa di Interventistica Cardiovascolare, Pineta Grande Hospital, Via Domitiana km 30.00, 81030 Castel Volturno, Italy
| | - Diego Maffeo
- Interventional Cardiology Unit, Cardiovascular Department, Fondazione Poliambulanza Istituto Ospedaliero, Brescia, Italy
| |
Collapse
|
7
|
Laricchia A, Cereda A, Lucreziotti S, Sticchi A, Regazzoli D, Reimers B, Colombo A, Latib A, Mangieri A. Expanding our horizons for the use of transcatheter self-expanding valves: what does the future hold? Expert Rev Cardiovasc Ther 2022; 20:497-501. [PMID: 35673979 DOI: 10.1080/14779072.2022.2085688] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
INTRODUCTION Transcatheter aortic valve implantation (TAVI) is an established alternative to aortic valve surgery in patient with severe aortic valve stenosis. As interventionalists are pushing towards treatment of patients with lower risk profile with a wide range of anatomies, contemporary transcatheter heart valves (THV) should offer an excellent performance in terms of residual gradient, rate of pacemaker and perivalvular leak. AREAS COVERED Self-expandable (SE) valve offer a valid alternative to balloon-expandable (BE) valves, nevertheless comparative trials suggest a better outcome of patients treated with BE over SE platforms. New generation SE valves offer an excellent outcome in terms of procedural safety, however implementations in valve design and performance are required to reach the BE valves performance. EXPERT COMMENTARY in the near future, new devices should be able to obtain optimal results with a negligible rate of complications. Developments in the design of the delivery system together with refinements in valve technology are desirable to achieve results which are comparable to surgical aortic valve replacement.
Collapse
Affiliation(s)
| | - Alberto Cereda
- Cardiovascular department, ASST Santi Paolo Carlo, Milano, Italy
| | | | - Alessandro Sticchi
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele-Milan, Italy.,Cardio Center, Humanitas Clinical and Research Hospital IRCCS, Rozzano, Milan, Italy
| | - Damiano Regazzoli
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele-Milan, Italy.,Cardio Center, Humanitas Clinical and Research Hospital IRCCS, Rozzano, Milan, Italy
| | - Bernhard Reimers
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele-Milan, Italy.,Cardio Center, Humanitas Clinical and Research Hospital IRCCS, Rozzano, Milan, Italy
| | - Antonio Colombo
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele-Milan, Italy.,Cardio Center, Humanitas Clinical and Research Hospital IRCCS, Rozzano, Milan, Italy
| | - Azeem Latib
- Department of Cardiology, Montefiore Medical Center, 1825 Eastchester Road, Bronx, NY 10461, USA
| | - Antonio Mangieri
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele-Milan, Italy.,Cardio Center, Humanitas Clinical and Research Hospital IRCCS, Rozzano, Milan, Italy
| |
Collapse
|
8
|
Casenghi M, Rubbio AP, Menicanti L, Bedogni F, Testa L. Durability of surgical and transcatheter aortic bioprostheses. A review of the literature. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2022; 42:161-170. [DOI: 10.1016/j.carrev.2022.03.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2021] [Revised: 03/07/2022] [Accepted: 03/07/2022] [Indexed: 11/03/2022]
|
9
|
Gallo M, Fovino LN, Blitzer D, Doulamis IP, Guariento A, Salvador L, Tagliari AP, Ferrari E. Transcatheter aortic valve replacement for structural degeneration of previously implanted transcatheter valves (TAVR-in-TAVR): a systematic review. Eur J Cardiothorac Surg 2021; 61:967-976. [PMID: 34662376 DOI: 10.1093/ejcts/ezab443] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2021] [Revised: 08/26/2021] [Accepted: 09/19/2021] [Indexed: 11/13/2022] Open
Abstract
OBJECTIVES Transcatheter aortic valve replacement (TAVR) represents a valid treatment for patients with aortic valve stenosis and high or intermediate surgical risk. However, biological transcatheter valves can also experience a structural degeneration after years, and a redo-TAVR procedure (TAVR-in-TAVR) can be a valid option. We revised the current available literature for indications, procedural and technical details and outcome on TAVR-in-TAVR procedures for degenerated TAVR valves. METHODS A systematic search was conducted in the public medical database for scientific articles on TAVR-in-TAVR procedures for degenerated transcatheter valves. Data on demographics, indications, first and second transcatheter valve type and size, mortality, complications and follow-up were extracted and analysed. RESULTS A total of 13 studies (1 multicentre, 3 case series, 9 case reports) were included in this review, with a total amount of 160 patients treated with TAVR-in-TAVR procedures for transcatheter valve failure. The mean age was 74.8 ± 7.8 with 84 males (52.8%). The mean elapsed time from the first TAVR procedure was 58.1 ± 23.4 months. Main indication for TAVR-in-TAVR was pure stenosis (38.4%, with mean gradient of 44.5 ± 18.5 mmHg), regurgitation (31.4%), mixed stenosis and regurgitation (29.5%) and leaflet thrombosis (8.8%). Procedural success rate was 86.8%, with second TAVR valve malposition occurred in 4 cases (2.5%). The hospital mortality rate was 1.25% (2/160). Post-procedural echocardiographic control showed moderate regurgitation in 5.6% of patients (9/160) and residual transvalvular mean gradient ≥20 mmHg in 5% of cases. Postoperative complications included major vascular complications (8.7%), new pacemaker implantation (8.7%), acute kidney failure (3.7%), stroke (0.6%) and coronary obstruction (0.6%). The mean follow-up time was 6 ± 5.6 months with 1 non-cardiovascular death reported. CONCLUSIONS TAVR-in-TAVR represents a valid alternative to standard surgery for the treatment of degenerated transcatheter valves in high-risk patients. Despite these promising results, further studies are required to assess durability and haemodynamic performances of the second TAVR valve. SUBJ COLLECTION 117, 122, 125.
Collapse
Affiliation(s)
- Michele Gallo
- Department of Cardiac Surgery, Cardiocentro Ticino Institute, Lugano, Switzerland.,Department of Cardiac Surgery, San Bortolo Hospital, Vicenza, Italy
| | - Luca Nai Fovino
- Department of Cardiology, University of Padova, Padova, Italy
| | - David Blitzer
- Department of Surgery, New York Presbyterian Hospital, Columbia University, New York, NY, USA
| | - Ilias P Doulamis
- Department of Cardiac Surgery, Boston Children's Hospital, Harvard Medical School, Boston, MA, USA
| | - Alvise Guariento
- Department of Cardiovascular Surgery, Labatt Family Heart Centre, The Hospital for Sick Children, University of Toronto, Toronto, ON, Canada
| | - Loris Salvador
- Department of Cardiac Surgery, San Bortolo Hospital, Vicenza, Italy
| | - Ana Paula Tagliari
- Postgraduate Program in Health Sciences: Cardiology and Cardiovascular Sciences, Universidade Federal do Rio Grande do Sul, Porto Alegre, Brazil
| | - Enrico Ferrari
- Department of Cardiac Surgery, Cardiocentro Ticino Institute, Lugano, Switzerland.,University of Zurich, Zurich, Switzerland
| |
Collapse
|