1
|
Fujita K, Matsumura K, Sugimoto K, Onishi K, Kakehi K, Yoshida A, Kawamura T, Yasuda M, Matsuzoe H, Mizutani K, Miyoshi T, Ueno M, Sakaguchi G, Nakazawa G. Early clinical outcomes of transcatheter aortic valve implantation using the NAVITOR system. Cardiovasc Interv Ther 2025; 40:378-388. [PMID: 39762512 PMCID: PMC11910440 DOI: 10.1007/s12928-024-01081-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2024] [Accepted: 12/23/2024] [Indexed: 03/16/2025]
Abstract
Transcatheter aortic valve implantation (TAVI) using the NAVITOR system has been relatively underreported due to its recent introduction in Japan. This study aimed to assess the short-term outcomes of TAVI with the NAVITOR in real-world clinical practice. Patients with severe aortic stenosis who underwent TAVI using the NAVITOR system at our institution between December 2022 and December 2023 were prospectively enrolled. We evaluated the 30-day post-TAVI outcomes using the Valve Academic Research Consortium 3 (VARC-3). Among 32 consecutive patients (mean age, 84 years; 19% female), technical success was achieved in 31 (96.8%). One patient developed a subclavian artery vascular dissection, requiring balloon angioplasty during the TAVI procedure, and another received a permanent pacemaker due to persistent advanced atrioventricular block. At the 30-day follow-up, device success was achieved in 31 (96.8%) patients, with early safety observed in 27 (84.3%). One patient experienced sudden unexplained death after discharge. None of the patients experienced myocardial infarction, valve embolisation, life-threatening bleeding, or acute kidney injury within 30 days after the procedure. Echocardiographic follow-up showed a median effective orifice area index of 1.26 ± 0.27. Contrast-enhanced computed tomography was performed in 19 patients 30 days after the procedure, revealing hypo-attenuated leaflet thickening (HALT) in 10 (52.6%). Although the 30-day outcomes of TAVI using the NAVITOR system appeared promising, a relatively high incidence of HALT was observed.
Collapse
Affiliation(s)
- Kosuke Fujita
- Division of Cardiology, Department of Medicine, Kindai University Faculty of Medicine, 377-2 Ohno-Higashi, Osakasayama, Osaka, 589-8511, Japan
| | - Koichiro Matsumura
- Division of Cardiology, Department of Medicine, Kindai University Faculty of Medicine, 377-2 Ohno-Higashi, Osakasayama, Osaka, 589-8511, Japan
| | - Keishiro Sugimoto
- Division of Cardiology, Department of Medicine, Kindai University Faculty of Medicine, 377-2 Ohno-Higashi, Osakasayama, Osaka, 589-8511, Japan
| | - Kyohei Onishi
- Division of Cardiology, Department of Medicine, Kindai University Faculty of Medicine, 377-2 Ohno-Higashi, Osakasayama, Osaka, 589-8511, Japan
| | - Kazuyoshi Kakehi
- Division of Cardiology, Department of Medicine, Kindai University Faculty of Medicine, 377-2 Ohno-Higashi, Osakasayama, Osaka, 589-8511, Japan
| | - Ayano Yoshida
- Division of Cardiology, Department of Medicine, Kindai University Faculty of Medicine, 377-2 Ohno-Higashi, Osakasayama, Osaka, 589-8511, Japan
| | - Takayuki Kawamura
- Division of Cardiology, Department of Medicine, Kindai University Faculty of Medicine, 377-2 Ohno-Higashi, Osakasayama, Osaka, 589-8511, Japan
| | - Masakazu Yasuda
- Division of Cardiology, Sakurabashi Watanabe Advanced Healthcare Hospital, Osaka, Japan
| | - Hiroki Matsuzoe
- Division of Cardiology, Department of Medicine, Kindai University Faculty of Medicine, 377-2 Ohno-Higashi, Osakasayama, Osaka, 589-8511, Japan
| | - Kazuki Mizutani
- Division of Cardiology, Department of Medicine, Kindai University Faculty of Medicine, 377-2 Ohno-Higashi, Osakasayama, Osaka, 589-8511, Japan
- Division of Cardiology, Sapporo Cardio Vascular Clinic, Sapporo, Japan
| | - Tatsuya Miyoshi
- Division of Cardiology, Department of Medicine, Kindai University Faculty of Medicine, 377-2 Ohno-Higashi, Osakasayama, Osaka, 589-8511, Japan
| | - Masafumi Ueno
- Division of Cardiology, Department of Medicine, Kindai University Faculty of Medicine, 377-2 Ohno-Higashi, Osakasayama, Osaka, 589-8511, Japan
| | - Genichi Sakaguchi
- Division of Cardiovascular Surgery, Department of Surgery, Kindai University Faculty of Medicine, Osakasayama, Japan
| | - Gaku Nakazawa
- Division of Cardiology, Department of Medicine, Kindai University Faculty of Medicine, 377-2 Ohno-Higashi, Osakasayama, Osaka, 589-8511, Japan.
| |
Collapse
|
2
|
Onoda H, Ueno H, Hida Y, Imamura T, Kinugawa K. Re-sheathing failure with Navitor during transcatheter aortic valve implantation: a case report. Eur Heart J Case Rep 2025; 9:ytaf015. [PMID: 39872673 PMCID: PMC11770386 DOI: 10.1093/ehjcr/ytaf015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2024] [Revised: 10/22/2024] [Accepted: 01/13/2025] [Indexed: 01/30/2025]
Abstract
Background Self-expanding valves used in transcatheter aortic valve implantation (TAVI) are designed to allow recapture and repositioning, facilitating optimal placement and mitigating conduction disturbances and paravalvular leakage. Here, we present a rare case in which the Navitor (Abbott Structural Heart, Santa Clara, CA, USA) could not be recaptured. Case summary An 81-year-old Japanese woman with very severe aortic stenosis and a massively calcified nodule at the non-coronary cusp (NCC) underwent TAVI with a 25 mm Navitor valve. During the initial deployment attempt, non-uniform expansion (NUE) was observed on the NCC side when the valve was 80% deployed. An attempt was made to recapture and reposition the valve, but the delivery system capsule failed to fully re-sheath the prosthesis, leaving approximately one-third of the valve outside the capsule and preventing complete recapture. The Navitor was promptly redeployed while still within the basal ring. Following redeployment, the NUE resolved, and the valve was successfully positioned 3 mm below the basal ring on the NCC side and 4 mm below the left coronary cusp. We hypothesized that interference between the capsule tip and the calcified nodule on the NCC leaflet inhibited the re-sheathing process. Conclusion This report documents a rare complication involving the failure to recapture the Navitor valve. In cases with large calcified nodules on the leaflet, caution is essential during the re-sheathing process. We strongly recommend re-deploying the prosthesis rather than attempting to remove it from the basal ring to minimize procedural risks and ensure proper valve placement.
Collapse
Affiliation(s)
- Hiroshi Onoda
- The Second Department of Internal Medicine, University of Toyama, 2630 Sugitani, Toyama, Toyama 930-0194, Japan
| | - Hiroshi Ueno
- The Second Department of Internal Medicine, University of Toyama, 2630 Sugitani, Toyama, Toyama 930-0194, Japan
| | - Yuki Hida
- The Second Department of Internal Medicine, University of Toyama, 2630 Sugitani, Toyama, Toyama 930-0194, Japan
| | - Teruhiko Imamura
- The Second Department of Internal Medicine, University of Toyama, 2630 Sugitani, Toyama, Toyama 930-0194, Japan
| | - Koichiro Kinugawa
- The Second Department of Internal Medicine, University of Toyama, 2630 Sugitani, Toyama, Toyama 930-0194, Japan
| |
Collapse
|
3
|
Bharucha AH, Kanyal R, Mullen M, Patel K, Smith D, Shome J, Blackman DJ, Aktaa S, Williams PD, Khogali S, Dworakowski R, Eskandari M, Byrne J, MacCarthy P. Transcatheter Aortic Valve Replacement With the Navitor System: Real-World United Kingdom Experience. Am J Cardiol 2024; 222:23-28. [PMID: 38692400 DOI: 10.1016/j.amjcard.2024.04.036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/04/2024] [Revised: 04/05/2024] [Accepted: 04/19/2024] [Indexed: 05/03/2024]
Abstract
The Navitor transcatheter heart valve (THV) is the latest iteration of the Portico self-expanding valve system. Early prospective studies have shown promising outcomes, however, there is a lack of complementary 'real-world' data. This study aimed to assess early safety and efficacy outcomes of the Navitor THV using registry data from 6 high-volume United Kingdom transcatheter aortic valve replacement (TAVR) centers. Demographic, procedural, and in-hospital outcome data were retrieved from 6 United Kingdom centers. The primary safety end point was 30-day mortality. Primary efficacy end points were procedural success, mean aortic gradient, and ≥moderate paravalvular leak. Secondary end points included rates of new permanent pacemaker implantation, stroke, and vascular injury. A total of 574 patients (mean age 83.4 years; 54.5% female) underwent Navitor TAVR between January 2020 and May 2023. The 30-day mortality in this patient cohort was 1.6%. Procedural success was 98.1%, mean echo-derived gradient post-TAVR was 7.7 ± 4.8 mm Hg (95% confidence interval [CI] 7.2 to 8.3, p <0.001) and 5.1% of patients had ≥moderate paravalvular leak (sample proportion estimate [p̂] = 0.051, 95% CI [0.035, 0.073], p <0.001). New permanent pacemaker implantation to discharge was required in 11% (p̂ = 0.119, 95% CI 0.088 to 0.158, p <0.001), stroke occurred in 1.2% of patients (p̂ = 0.017, 95% CI 0.006 to 0.036, p <0.001) and significant vascular injury in 1.6% (p̂ = 0.014, 95% CI 0.005 to 0.032, p <0.001). In conclusion, early procedural outcomes with Navitor TAVR compare favorably to new-generation THVs. Procedural success was high with a low incidence of complications.
Collapse
Affiliation(s)
- Apurva H Bharucha
- Department of Cardiology, King's College Hospital, London, United Kingdom
| | - Ritesh Kanyal
- Department of Cardiology, King's College Hospital, London, United Kingdom
| | - Michael Mullen
- Department of Cardiology, Barts Health NHS Trust, London, United Kingdom
| | - Kush Patel
- Department of Cardiology, Barts Health NHS Trust, London, United Kingdom
| | - David Smith
- Department of Cardiology, Morriston Cardiac Centre, Swansea, United Kingdom
| | - Joy Shome
- Department of Cardiology, Morriston Cardiac Centre, Swansea, United Kingdom
| | - Daniel J Blackman
- Department of Cardiology, Leeds Teaching Hospitals NHS Trust, Leeds, United Kingdom
| | - Suleman Aktaa
- Department of Cardiology, Leeds Teaching Hospitals NHS Trust, Leeds, United Kingdom
| | - Paul D Williams
- Department of Cardiology, James Cook University Hospital, Middlesbrough, United Kingdom
| | - Saib Khogali
- Department of Cardiology, New Cross Hospital, Wolverhampton, United Kingdom
| | - Rafal Dworakowski
- Department of Cardiology, King's College Hospital, London, United Kingdom
| | - Mehdi Eskandari
- Department of Cardiology, King's College Hospital, London, United Kingdom
| | - Jonathan Byrne
- Department of Cardiology, King's College Hospital, London, United Kingdom
| | - Philip MacCarthy
- Department of Cardiology, King's College Hospital, London, United Kingdom.
| |
Collapse
|
4
|
Malhotra G, Cole CMW, Cox SV, Ross JDW, Dooris M, Moore PT, Chong AA, Dahiya A, Korver K, Hayman SM, Camuglia AC. Third-Generation Transcatheter Aortic Heart Valve with Reverse Parachute Sealing Cuff in Patients with Aortic Valve Disease. Heart Lung Circ 2024; 33:324-331. [PMID: 38184427 DOI: 10.1016/j.hlc.2023.11.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Revised: 09/18/2023] [Accepted: 11/08/2023] [Indexed: 01/08/2024]
Abstract
BACKGROUND The Navitor (Abbott Inc, IL, USA) transcatheter heart valve is a novel third-generation self-expanding bioprosthesis with specific features to mitigate paravalvular regurgitation (PVR). Owing to its novelty, there is a paucity of data on its application in clinical practice. METHODS Consecutive cohort analysis of the use of the Navitor system in an as-treated clinical setting at a quaternary heart hospital. RESULTS Sixty consecutive non-clinical trial patients treated with Navitor were identified. All patients underwent a successful procedure. The mean age was 79.3 years (±SD 7.82), 56.67% (n=34) were female, and the mean STS score was 4.87 (±SD 5.70). At 30 days post-procedure, all patients were alive with no readmissions for heart failure. One patient had a major vascular complication (1.7%). Four patients (7.14% of patients without a pre-existing pacemaker) received a new permanent pacemaker. Two patients (3.4%) had a non-disabling stroke. PVR at 30 days was trivial or none in 75% of patients, and no patient had worse than mild PVR. CONCLUSIONS The Navitor system in this as-treated cohort was associated with favourable clinical, haemodynamic, and safety outcomes.
Collapse
Affiliation(s)
- Ganeev Malhotra
- Division of Heart Lung and Critical Care, Princess Alexandra Hospital, Brisbane, QLD, Australia; University of Queensland, Brisbane, QLD, Australia
| | - Chris M W Cole
- Division of Heart Lung and Critical Care, Princess Alexandra Hospital, Brisbane, QLD, Australia; University of Queensland, Brisbane, QLD, Australia
| | - Stephen V Cox
- Division of Heart Lung and Critical Care, Princess Alexandra Hospital, Brisbane, QLD, Australia; University of Queensland, Brisbane, QLD, Australia
| | - Jordan D W Ross
- Division of Heart Lung and Critical Care, Princess Alexandra Hospital, Brisbane, QLD, Australia; University of Queensland, Brisbane, QLD, Australia
| | - Mark Dooris
- University of Queensland, Brisbane, QLD, Australia; Mater Hospital and Health Service, Brisbane, QLD, Australia
| | - Peter T Moore
- Division of Heart Lung and Critical Care, Princess Alexandra Hospital, Brisbane, QLD, Australia; University of Queensland, Brisbane, QLD, Australia
| | - Adrian A Chong
- Division of Heart Lung and Critical Care, Princess Alexandra Hospital, Brisbane, QLD, Australia; University of Queensland, Brisbane, QLD, Australia; Mater Hospital and Health Service, Brisbane, QLD, Australia
| | - Arun Dahiya
- Division of Heart Lung and Critical Care, Princess Alexandra Hospital, Brisbane, QLD, Australia; University of Queensland, Brisbane, QLD, Australia
| | - Kellee Korver
- Division of Heart Lung and Critical Care, Princess Alexandra Hospital, Brisbane, QLD, Australia; University of Queensland, Brisbane, QLD, Australia
| | - Sam M Hayman
- University of Queensland, Brisbane, QLD, Australia; Mater Hospital and Health Service, Brisbane, QLD, Australia; Royal Brisbane and Women's Hospital, Brisbane, QLD, Australia
| | - Anthony C Camuglia
- Division of Heart Lung and Critical Care, Princess Alexandra Hospital, Brisbane, QLD, Australia; University of Queensland, Brisbane, QLD, Australia; Mater Hospital and Health Service, Brisbane, QLD, Australia.
| |
Collapse
|
5
|
Briedis K, Aldujeli A, Zaliunas R, Benetis R. Early Safety and Performance of the Premounted Dry-Pericardium Vienna Self-Expandable Transcatheter Aortic Valve System: 30-Day Outcomes of the First-in-Human VIVA Feasibility Study. Am J Cardiol 2023; 204:302-311. [PMID: 37567022 DOI: 10.1016/j.amjcard.2023.07.109] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/25/2023] [Revised: 07/15/2023] [Accepted: 07/24/2023] [Indexed: 08/13/2023]
Abstract
The purpose of this first-in-human (FIH) study was to determine the safety and feasibility of the transfemoral premounted dry-pericardium Vienna Self-Expandable Supra-Annular Aortic Valve System. This novel system is repositionable and retrievable and comes already premounted on the delivery system, eliminating the need for assembly and crimping of the device before valve implantation. This is a prospective, nonrandomized, single-arm, single-center, first-stage FIH feasibility study, which will be followed by a second-stage pivotal, multicenter, multinational study in symptomatic patients with severe aortic stenosis. The first-stage FIH study evaluated the safety and feasibility of the device in 10 patients with severe aortic stenosis based on recommendations by the Valve Academic Research Consortium-2 for transcatheter aortic valve implantations. The mean patient age was 79 ± 5 years, 60% were male, and all patients were in New York Heart Association functional class II to III. The primary safety end point was successful when all patients were alive at 30-day follow-up. Device and technical success were observed in all patients. Two patients had a stroke, 1 of which occurred 5 days after the procedure. New permanent pacemakers were implanted in 2 patients (22.2%), of which only 1 was because of complete heart block. Only 1 patient (10%) had moderate paravalvular leak at 30 days. After the procedure, the mean aortic valve gradient decreased from 48.7 ± 10.8 mm Hg to 8.8 ± 4.3 mm Hg. In conclusion, this FIH feasibility study demonstrates successful procedural feasibility, with no 30-day mortality and favorable valve hemodynamic performance, leading to an improvement in quality of life. ClinicalTrials.gov identifier NCT04861805.
Collapse
Affiliation(s)
| | | | | | - Rimantas Benetis
- Cardiac, Thoracic and Vascular Surgery, Lithuanian University of Health Sciences, Kaunas, Lithuania
| |
Collapse
|
6
|
Giordano A, Schaefer A, Bhadra OD, Barbanti M, Costa G, Sammartino S, Sondergaard L, De Backer O, Dalsgaard M, D'Ascenzo F, Musto C, Fineschi M, Maisano F, Testa L, Vercellino M, Berni A, Galasso G, Cammardella AG, Morello A, Pepe M, Albanese M, Cimmino M, Giordano S, Biondi-Zoccai G, Corcione N. Outcomes of Transcatheter Aortic Valve Replacement in Patients With Severely Reduced Left Ventricular Systolic Function in the Low Systolic Function and Transcatheter Aortic Valve Implantation (LOSTAVI) International Registry. Am J Cardiol 2023; 201:349-358. [PMID: 37423004 DOI: 10.1016/j.amjcard.2023.06.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Revised: 05/30/2023] [Accepted: 06/05/2023] [Indexed: 07/11/2023]
Abstract
Transcatheter aortic valve replacement (TAVR) is an established therapy for severe, symptomatic aortic valve stenosis even in patients with impaired left ventricular systolic function. However, there is uncertainty on the clinical effectiveness of the currently available TAVR devices in patients with reduced left ventricular ejection fraction (LVEF). The LOSTAVI (Low Systolic function and Transcatheter Aortic Valve Implantation) registry is a retrospective observational study using baseline, procedural, discharge, and long-term follow-up details. A total of 3 groups of interest were distinguished: extremely reduced LVEF (<25%), severely reduced LVEF (25% to 30%), and reduced LVEF (31% to 35%). Unadjusted and adjusted analyses were carried out for in-hospital and follow-up outcomes. A total of 923 patients were included from 12 centers, with 146 patients (16%) with LVEF <25%, 425 (46%) with LVEF 25% to 30%, and 352 (38%) with LVEF 31% to 35%. Several baseline and procedural features were different across groups, including age, risk, functional class, and prevalence of bicuspid disease (all p <0.05). In-hospital mortality was similar in the 3 groups (7 [4.8%], 18 [4.2%], and 7 [2.0%], respectively, p = 0.661), but major adverse events were more common in those with extremely reduced and severely reduced LVEF (19 [13%], 53 [13%], and 25 [7.1%], respectively, p = 0.024). The 12-month follow-up confirmed the significant detrimental impact of reduced LVEF on both death (21 [14%], 49 [12%], and 25 [7.1%], respectively, p = 0.024) and major adverse events (37 [25%], 89 [21%], and 53 [15%], respectively, p = 0.016). The adjusted analysis confirmed the significant prognostic role of LVEF on both outcomes, whereas TAVR device type was not associated with death or major adverse events (all p >0.05). In conclusion, TAVR yields favorable early and 1-year results in patients with reduced LVEF, including those with extremely depressed systolic dysfunction. However, reduced LVEF still represents a major adverse prognostic factor for both short- and mid-term outcomes.
Collapse
Affiliation(s)
- Arturo Giordano
- Cardiovascular Interventions Unit, Pineta Grande Hospital, Castel Volturno, Italy; Hemodynamics Unit, Santa Lucia Hospital, San Giuseppe Vesuviano, Italy
| | - Andreas Schaefer
- Department of Cardiovascular Surgery, University Heart and Vascular Center of Hamburg, Hamburg, Germany
| | - Oliver D Bhadra
- Department of Cardiovascular Surgery, University Heart and Vascular Center of Hamburg, Hamburg, Germany
| | - Marco Barbanti
- Division of Cardiology, Enna Kore University, Enna, Italy
| | - Giuliano Costa
- Division of Cardiology, A.G. Rodolico-San Marco Hospital, Catania, Italy
| | - Sofia Sammartino
- Division of Cardiology, A.G. Rodolico-San Marco Hospital, Catania, Italy
| | - Lars Sondergaard
- Department of Cardiology, Copenhagen University Hospital, Rigshospitalet, Denmark
| | - Ole De Backer
- Department of Cardiology, Copenhagen University Hospital, Rigshospitalet, Denmark
| | - Marie Dalsgaard
- Department of Cardiology, Copenhagen University Hospital, Rigshospitalet, Denmark
| | - Fabrizio D'Ascenzo
- Division of Cardiology, Cardiovascular and Thoracic Department of Medical Sciences, University of Turin Hospital, Turin, Italy
| | - Carmine Musto
- Department of Cardiosciences, A.O. San Camillo Forlanini Hospital, Rome, Italy
| | - Massimo Fineschi
- Interventional Cardiology Unit, Siena University Hospital, Siena, Italy
| | - Francesco Maisano
- Cardio-Thoracic-Vascular Department, San Raffaele Hospital, Milan, Italy
| | - Luca Testa
- Department of Cardiology, San Donato Hospital, San Donato Milanese, Milan, Italy
| | - Matteo Vercellino
- Department of Internal Medicine and Specialties, University of Genoa, and Cardiology Unit, Cardiothoracic and Vascular Department, San Martino Hospital, Genoa, Italy
| | - Andrea Berni
- Interventional Cardiology Unit, Sant'Andrea University Hospital, Rome, Italy
| | - Gennaro Galasso
- Division of Cardiology, Department of Medicine, Surgery and Dentistry, University of Salerno, Salerno, Italy
| | - Antonio G Cammardella
- Department of Cardiac Surgery and Heart Transplantation, San Camillo Forlanini Hospital, Rome, Italy
| | - Alberto Morello
- Cardiovascular Interventions Unit, Pineta Grande Hospital, Castel Volturno, Italy; Hemodynamics Unit, Santa Lucia Hospital, San Giuseppe Vesuviano, Italy
| | - Martino Pepe
- Division of Cardiology, Department of Interdisciplinary Medicine (D.I.M.), University of Bari Aldo Moro, Bari, Italy
| | - Michele Albanese
- Cardiovascular Interventions Unit, Pineta Grande Hospital, Castel Volturno, Italy; Hemodynamics Unit, Santa Lucia Hospital, San Giuseppe Vesuviano, Italy
| | - Michele Cimmino
- Cardiovascular Interventions Unit, Pineta Grande Hospital, Castel Volturno, Italy; Hemodynamics Unit, Santa Lucia Hospital, San Giuseppe Vesuviano, Italy
| | - Salvatore Giordano
- Division of Cardiology, Department of Medical and Surgical Sciences, Magna Graecia University, Catanzaro, Italy
| | - Giuseppe Biondi-Zoccai
- Department of Medical-Surgical Sciences and Biotechnologies, Sapienza University of Rome, Latina, Italy; Mediterranea Cardiocentro, Napoli, Italy.
| | - Nicola Corcione
- Cardiovascular Interventions Unit, Pineta Grande Hospital, Castel Volturno, Italy; Hemodynamics Unit, Santa Lucia Hospital, San Giuseppe Vesuviano, Italy
| |
Collapse
|
7
|
Leone PP, Scotti A, Ho EC, Assafin M, Doolittle J, Chau M, Slipczuk L, Levitus M, Regazzoli D, Mangieri A, Latib A. Prosthesis Tailoring for Patients Undergoing Transcatheter Aortic Valve Implantation. J Clin Med 2023; 12:338. [PMID: 36615141 PMCID: PMC9821207 DOI: 10.3390/jcm12010338] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Revised: 12/28/2022] [Accepted: 12/29/2022] [Indexed: 01/03/2023] Open
Abstract
Transcatheter aortic valve implantation (TAVI) has risen over the past 20 years as a safe and effective alternative to surgical aortic valve replacement for treatment of severe aortic stenosis, and is now a well-established and recommended treatment option in suitable patients irrespective of predicted risk of mortality after surgery. Studies of numerous devices, either newly developed or reiterations of previous prostheses, have been accruing. We hereby review TAVI devices, with a focus on commercially available options, and aim to present a guide for prosthesis tailoring according to patient-related anatomical and clinical factors that may favor particular designs.
Collapse
Affiliation(s)
- Pier Pasquale Leone
- Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY 10461, USA
- Department of Biomedical Sciences, Humanitas University, 20072 Pieve Emanuele, Italy
- Cardio Center, IRCCS Humanitas Research Hospital, 20089 Rozzano, Italy
| | - Andrea Scotti
- Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY 10461, USA
- Cardiovascular Research Foundation, New York, NY 10019, USA
| | - Edwin C. Ho
- Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY 10461, USA
| | - Manaf Assafin
- Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY 10461, USA
| | - James Doolittle
- Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY 10461, USA
| | - Mei Chau
- Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY 10461, USA
| | - Leandro Slipczuk
- Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY 10461, USA
| | - Matthew Levitus
- Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY 10461, USA
| | - Damiano Regazzoli
- Cardio Center, IRCCS Humanitas Research Hospital, 20089 Rozzano, Italy
| | - Antonio Mangieri
- Cardio Center, IRCCS Humanitas Research Hospital, 20089 Rozzano, Italy
| | - Azeem Latib
- Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY 10461, USA
| |
Collapse
|
8
|
Musumeci G, Annibali G. The active sealing cuff revolution. Catheter Cardiovasc Interv 2022; 100:120-121. [PMID: 35819149 DOI: 10.1002/ccd.30305] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2022] [Accepted: 06/11/2022] [Indexed: 11/09/2022]
Affiliation(s)
- Giuseppe Musumeci
- Cardiology Department, Azienda Ospedaliera Ordine Mauriziano di Torino, Turin, Italy
| | - Gianmarco Annibali
- Cardiology Department, Azienda Ospedaliera Ordine Mauriziano di Torino, Turin, Italy
| |
Collapse
|