1
|
D’Onofrio A, Marini M, Rovaris G, Zanotto G, Calvi V, Iacopino S, Biffi M, Solimene F, Della Bella P, Caravati F, Pisanò EC, Amellone C, D’Alterio G, Pedretti S, Santobuono VE, Russo AD, Nicolis D, De Salvia A, Baroni M, Quartieri F, Manzo M, Rapacciuolo A, Saporito D, Maines M, Marras E, Bontempi L, Morani G, Giacopelli D, Gargaro A, Giammaria M. Prognostic significance of remotely monitored nocturnal heart rate in heart failure patients with reduced ejection fraction. Heart Rhythm 2022. [DOI: 10.1016/j.hrthm.2022.10.018] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|
2
|
Vamos M, Nemeth M, Balazs T, Zima E, Duray GZ. Rationale and feasibility of the atrioventricular single-lead ICD systems with a floating atrial dipole (DX) in clinical practice. Trends Cardiovasc Med 2021; 32:84-89. [PMID: 33482321 DOI: 10.1016/j.tcm.2021.01.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/28/2020] [Revised: 01/12/2021] [Accepted: 01/14/2021] [Indexed: 01/30/2023]
Abstract
Cardiac implantable electronic devices establish proper therapy for the prevention of sudden cardiac death, significantly reducing the morbidity and mortality of patients with arrhythmias and heart failure. It is well-known that the number of electrodes increases the risk of complications. To preserve the benefit of atrial sensing without the need to implant an additional lead, a single-lead ICD system with a floating atrial dipole (DX ICD lead) has been developed. Besides all of the potential benefits, the necessity of a reliable and stable atrial sensing via the floating dipole could be the main concern against the use of this lead type. In the current generation of DX devices, the specially filtered atrial signal seems to be high enough and stable over time, which is crucial in the early detection of atrial arrhythmias, discrimination between different forms of tachycardias in order to prevent inappropriate ICD therapy, and achieving an optimal atrioventricular and interventricular synchrony in patients with a two-lead CRT-DX system. The present review summarizes the benefits and potential drawbacks of the DX ICD systems based on the available literature, furthermore, proposes an evidence-based algorithm of ICD type selection.
Collapse
Affiliation(s)
- Mate Vamos
- Department of Internal Medicine, Cardiac Electrophysiology Division, University of Szeged, Semmelweis u. 8., 6725 Szeged, Szeged, Hungary.
| | | | | | - Endre Zima
- Heart and Vascular Center, Semmelweis University, Budapest, Hungary
| | - Gabor Zoltan Duray
- Department of Cardiology, Medical Centre, Hungarian Defense Forces, Budapest, Hungary
| |
Collapse
|
3
|
Abstract
Over the years, pacemakers have evolved from a life-saving tool to prevent asystole to a device to treat heart rhythm disorders and heart failure, aiming at improving both cardiac function and clinical outcomes. Cardiac stimulation nowadays aims to correct the electrophysiologic roots of mechanical inefficiency in different structural heart diseases. This has led to awareness of the concealed risks of customary cardiac pacing that can inadvertently cause atrioventricular and inter-/intra-ventricular dyssynchrony, and has promoted the development of new pacing modalities and the use of stimulation sites different from the right atrial appendage and the right ventricular apex. The perspective of truly physiologic pacing is the leading concept of the continued research in the past 30 years, which has made cardiac stimulation procedure more sophisticated and challenging. In this article, we analyze the emerging evidence in favor of the available strategies to achieve an individualized physiologic setting in bradycardia pacing.
Collapse
|
4
|
Biffi M, Capobianco C, Spadotto A, Bartoli L, Sorrentino S, Minguzzi A, Piemontese GP, Angeletti A, Toniolo S, Statuto G. Pacing devices to treat bradycardia: current status and future perspectives. Expert Rev Med Devices 2020; 18:161-177. [PMID: 33336616 DOI: 10.1080/17434440.2021.1866543] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
Introduction: Cardiac stimulation evolved from life-saving devices to prevent asystole to the treatment of heart rhythm disorders and heart failure, capable of remote patient and disease-progression monitoring. Cardiac stimulation nowadays aims to correct the electrophysiologic roots of mechanical inefficiency in different structural heart diseases.Areas covered: Clinical experience, as per available literature, has led to awareness of the concealed risks of customary cardiac pacing, that can inadvertently cause atrio-ventricular and inter/intra-ventricular dyssynchrony. New pacing modalities have emerged, leading to a new concept of what truly represents 'physiologic pacing' beyond maintenance of atrio-ventricular coupling. In this article we will analyze the emerging evidence in favor of the available strategies to achieve an individualized physiologic setting in bradycardia pacing, and the hints of future developments.Expert opinion: 'physiologic stimulation' technologies should evolve to enable an effective and widespread adoption. In one way new guiding catheters and the adoption of electrophysiologic guidance and non-fluoroscopic lead implantation are needed to make His-Purkinje pacing successful and effective at long term in a shorter procedure time; in the other way leadless stimulation needs to upgrade to a superior physiologic setting to mimic customary DDD pacing and possibly His-Purkinje pacing.
Collapse
Affiliation(s)
- Mauro Biffi
- Azienda Ospedaliero-Universitaria Di Bologna, Bologna, Italy
| | - Claudio Capobianco
- Azienda Ospedaliero-Universitaria Di Bologna, Bologna, Italy.,Department of Experimental, Diagnostic and Specialty Medicine, Bologna, Italy
| | - Alberto Spadotto
- Azienda Ospedaliero-Universitaria Di Bologna, Bologna, Italy.,Department of Experimental, Diagnostic and Specialty Medicine, Bologna, Italy
| | - Lorenzo Bartoli
- Azienda Ospedaliero-Universitaria Di Bologna, Bologna, Italy.,Department of Experimental, Diagnostic and Specialty Medicine, Bologna, Italy
| | - Sergio Sorrentino
- Azienda Ospedaliero-Universitaria Di Bologna, Bologna, Italy.,Department of Experimental, Diagnostic and Specialty Medicine, Bologna, Italy
| | - Alessandro Minguzzi
- Azienda Ospedaliero-Universitaria Di Bologna, Bologna, Italy.,Department of Experimental, Diagnostic and Specialty Medicine, Bologna, Italy
| | - Giuseppe Pio Piemontese
- Azienda Ospedaliero-Universitaria Di Bologna, Bologna, Italy.,Department of Experimental, Diagnostic and Specialty Medicine, Bologna, Italy
| | - Andrea Angeletti
- Azienda Ospedaliero-Universitaria Di Bologna, Bologna, Italy.,Department of Experimental, Diagnostic and Specialty Medicine, Bologna, Italy
| | - Sebastiano Toniolo
- Azienda Ospedaliero-Universitaria Di Bologna, Bologna, Italy.,Department of Experimental, Diagnostic and Specialty Medicine, Bologna, Italy
| | - Giovanni Statuto
- Azienda Ospedaliero-Universitaria Di Bologna, Bologna, Italy.,Department of Experimental, Diagnostic and Specialty Medicine, Bologna, Italy
| |
Collapse
|
5
|
Defibrillation testing during implantation of the subcutaneous implantable cardioverter-defibrillator: a necessary standard or becoming redundant? Neth Heart J 2020; 28:122-127. [PMID: 32780342 PMCID: PMC7419406 DOI: 10.1007/s12471-020-01448-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
Since the publication of the SIMPLE and NORDIC trials, defibrillation testing (DFT) is rarely performed during routine implantation of transvenous implantable cardioverter-defibrillators (ICD). However, the results of these trials cannot be extrapolated to the later introduced subcutaneous ICD (S-ICD) and a class I recommendation to perform DFT during the implantation of these devices remains in the current guidelines. Due to the high conversion success rate of DFT on one hand, and the risk of complications on the other, a significant number of physicians omit DFT in S‑ICD recipients. Several retrospective analyses have assessed the safety of the omission of DFT and report contradicting results and recommendations. It is known that implant position, as well as device factors and patient characteristics, influence defibrillation success. A better comprehension of these factors and their relationship could lead to more reliable and safer alternatives to DFT. An ongoing randomised clinical trial, which is expected to end in 2023, is the first study to implement a method that assesses implant position to identify patients who are likely to fail their DFT.
Collapse
|
6
|
Biffi M, D'Onofrio A, Pignalberi C, Pisanò EC, Iacopino S, Curnis A, Senatore G, Capucci A, Della Bella P, Calvi V, Zanotto G, Caravati F, Maglia G, Manzo M, Santamaria M, Ziacchi M, Lissoni F, Giacopelli D, Gargaro A, Solimene F. Rate-responsive pacing and atrial high rate episodes in cardiac resynchronization therapy patients: Is low heart rate the key? Clin Cardiol 2019; 42:820-828. [PMID: 31282000 PMCID: PMC6727874 DOI: 10.1002/clc.23227] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Revised: 06/20/2019] [Accepted: 06/28/2019] [Indexed: 01/24/2023] Open
Abstract
BACKGROUND The role of atrial rate-responsive (RR) pacing in cardiac resynchronization therapy (CRT) is unclear due to the favorable effect of rate lowering in systolic heart failure. Atrial high rate episodes (AHREs) in CRT recipients are particularly worrisome since they cause loss of CRT, beyond representing a stroke risk factor. HYPOTHESIS The presence of an association between RR and the incidence of AHREs. METHODS Daily remote transmissions from 836 CRT recipients were analyzed. AHREs were classified by duration: ≥15 minutes, ≥5 hours, and ≥ 24 hours. Variables possibly associated to AHREs were included in time-dependent proportional-hazard models, averaging over 30-day periods and adjusting for main baseline variables. RESULTS After a median follow-up of 23.9 (12.2-36.0) months, 507 (60.6%) patients experienced at least one 15-minute AHRE. RR function was programmed in 166 (19.8%) patients and was associated with an increased AHRE occurrence rate with hazard ratio (HR) ranging from 1.45 to 1.78 for the 3 cutoffs of episode duration. The negative effect of RR function was not observed in the subset of patients with low mean heart rate (<68 bpm). Higher mean heart rates increased AHRE risk (HR:1.02, P = .01), while CRT amount decreased it (HR:0.98, P < .01). The extent of atrial pacing did not predict AHRE occurrence. CONCLUSIONS RR pacing in CRT recipients is associated with increased AHRE occurrence, especially when an average heart rate > 68 bpm is attained.
Collapse
Affiliation(s)
- Mauro Biffi
- Policlinico Sant'Orsola‐MalpighiBolognaItaly
| | | | | | | | | | | | | | | | | | - Valeria Calvi
- Policlinico Vittorio Emanuele PO FerrarottoCataniaItaly
| | | | | | | | - Michele Manzo
- Azienda Ospedaliera Universitaria S.Giovanni di Dio e Ruggi D'AragonaSalernoItaly
| | | | | | | | | | | | | |
Collapse
|