Shibuki T, Fukushi K, Inoue K, Taira T, Satake T, Watanabe K, Sasaki M, Imaoka H, Mitsunaga S, Ikeda M. Covered self-expandable metallic stent placement for tumor bleeding from duodenal invasion in patients with unresectable pancreatic cancer.
DEN OPEN 2024;
4:e361. [PMID:
38601268 PMCID:
PMC11004547 DOI:
10.1002/deo2.361]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/05/2024] [Revised: 03/22/2024] [Accepted: 03/31/2024] [Indexed: 04/12/2024]
Abstract
Patients with unresectable pancreatic cancer often present with duodenal bleeding, a potentially life-threatening complication. In our case series of six unresectable pancreatic cancer patients with tumor bleeding, we explored the efficacy and safety of placement of a covered self-expandable metallic stent in the duodenum as a treatment option; we achieved a hemostasis rate of 67% (4/6), with a rebleeding rate of 50% (2/4). No complications occurred with stent placement, except for food impaction in one patient. Covered self-expandable metallic stent placement is a moderately effective treatment option for tumor bleeding in patients with unresectable pancreatic cancer. Although its hemostatic efficacy is limited, covered self-expandable metallic stent placement is safe and beneficial in some cases, warranting consideration in this disease setting with limited treatment options.