1
|
Sakai A, Masuda A, Takenaka M, Shiomi H, Omoto S, Yoshida A, Nakano R, Kawase Y, Kohashi S, Kodama Y. Multicenter Comparative Study of 6- and 10-mm Fully Covered Self-Expandable Metal Stents for Malignant Distal Biliary Obstruction During Neoadjuvant Chemotherapy for Resectable and Borderline Resectable Pancreatic Cancer. JOURNAL OF HEPATO-BILIARY-PANCREATIC SCIENCES 2025. [PMID: 40356346 DOI: 10.1002/jhbp.12157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/06/2025] [Revised: 03/21/2025] [Accepted: 04/25/2025] [Indexed: 05/15/2025]
Abstract
BACKGROUND The use of 10-mm fully covered self-expandable metal stents for preoperative bile duct drainage in patients with pancreatic cancer is increasing. However, these can cause complications (cholecystitis and pancreatitis) that may affect surgical outcomes. Smaller-diameter self-expandable metal stents may reduce these risks; however, the optimal stent size is unclear. METHODS Patients with pancreatic cancer who underwent neoadjuvant chemotherapy and placement of either 6 or 10-mm fully covered self-expandable metal stents for malignant distal biliary obstruction were included. The primary outcome was the 90-day incidence of recurrent biliary obstruction. Secondary outcomes were non-recurrent biliary obstruction and adverse events. RESULTS Fifty-three patients were enrolled (27 and 26 patients received 6-mm and 10-mm self-expandable metal stents, respectively). The 90-day incidence of recurrent biliary obstruction of the 6-mm group was significantly higher than that of the 10-mm group (30.8% vs. 3.8%; p = 0.02). Stent migration occurred more frequently in the 6-mm group (26.9% vs. 0%; p = 0.01). Although non-recurrent biliary obstruction adverse events were less common in the 6-mm group, the difference was not statistically significant (11.1% vs. 23.0%; p = 0.29). CONCLUSIONS The 10-mm self-expandable metal stents were more suitable for the preoperative management of pancreatic cancer.
Collapse
Affiliation(s)
- Arata Sakai
- Division of Gastroenterology, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Atsuhiro Masuda
- Division of Gastroenterology, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Mamoru Takenaka
- Department of Gastroenterology and Hepatology, Kindai University Faculty of Medicine, Osakasayama, Osaka, Japan
| | - Hideyuki Shiomi
- Division of Hepatobiliary and Pancreatic Diseases, Department of Gastroenterology, Hyogo Medical University, Nishinomiya, Hyōgo, Japan
| | - Shunsuke Omoto
- Department of Gastroenterology and Hepatology, Kindai University Faculty of Medicine, Osakasayama, Osaka, Japan
| | - Akihiro Yoshida
- Department of Gastroenterology and Hepatology, Kindai University Faculty of Medicine, Osakasayama, Osaka, Japan
| | - Ryota Nakano
- Division of Hepatobiliary and Pancreatic Diseases, Department of Gastroenterology, Hyogo Medical University, Nishinomiya, Hyōgo, Japan
| | - Yuta Kawase
- Division of Hepatobiliary and Pancreatic Diseases, Department of Gastroenterology, Hyogo Medical University, Nishinomiya, Hyōgo, Japan
| | - Shinya Kohashi
- Division of Gastroenterology, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Yuzo Kodama
- Division of Gastroenterology, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan
| |
Collapse
|
2
|
Yamashige D, Hijioka S, Nagashio Y, Maruki Y, Fukuda S, Yagi S, Okamoto K, Hara H, Hagiwara Y, Agarie D, Takasaki T, Ohba A, Kondo S, Morizane C, Ueno H, Sone M, Saito Y, Okusaka T. Potential of 6-mm-diameter fully covered self-expandable metal stents for unresectable malignant distal biliary obstruction: a propensity score-matched study. Clin Endosc 2025; 58:121-133. [PMID: 39895273 PMCID: PMC11837552 DOI: 10.5946/ce.2024.044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Revised: 03/30/2024] [Accepted: 04/02/2024] [Indexed: 02/04/2025] Open
Abstract
BACKGROUND/AIMS To date, only thinner-diameter metal stents have been evaluated for unresectable malignant distal biliary obstruction (UR-MDBO). This study investigated the outcomes and optimal cohorts for a 6-mm-diameter fully covered self-expandable metal stent (FCSEMS) compared with those for a 10-mm-diameter FCSEMS. METHODS This single-center retrospective cohort study included patients who underwent initial transpapillary metal stenting for UR-MDBO. Propensity score matching (1:1) analysis was performed. RESULTS Of 133/68 patients who underwent 6-mm/10-mm-diameter FCSEMS deployment, 59 in each group were selected. The median time to recurrent biliary obstruction was not significantly different between the groups (p=0.46). In contrast, use of the 6-mm-diameter FCSEMS resulted in a significantly reduced incidence of stent-related adverse events (AEs) (p=0.016), especially cholecystitis (p=0.032), and patients aged <70 years were particularly affected by this significant reduction. Among the patients in the end-stage cohort who were unable to continue chemotherapy after FCSEMS deployment, the free rate of stent-related events, including recurrent biliary obstruction and stent-related AEs, was significantly higher in the 6-mm group (p=0.027). CONCLUSIONS For UR-MDBO, a 6-mm-diameter FCSEMS can be an optimal and safe option in the younger cohort with a relatively high risk of AEs and in the end-stage cohort requiring safer drainage without interference from stent-related events during times of poor prognosis.
Collapse
Affiliation(s)
- Daiki Yamashige
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
| | - Susumu Hijioka
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
| | - Yoshikuni Nagashio
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
| | - Yuta Maruki
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
| | - Soma Fukuda
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
| | - Shin Yagi
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
| | - Kohei Okamoto
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
| | - Hidenobu Hara
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
| | - Yuya Hagiwara
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
| | - Daiki Agarie
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
| | - Tetsuro Takasaki
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
| | - Akihiro Ohba
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
| | - Shunsuke Kondo
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
| | - Chigusa Morizane
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
| | - Hideki Ueno
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
| | - Miyuki Sone
- Department of Diagnostic Radiology, National Cancer Center Hospital, Tokyo, Japan
| | - Yutaka Saito
- Endoscopy Division, National Cancer Center Hospital, Tokyo, Japan
| | - Takuji Okusaka
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
| |
Collapse
|
3
|
Harai S, Hijioka S, Yamada R, Ogura T, Fukasawa M, Okuda A, Horike H, Inoue D, Sekine M, Ishida Y, Koga T, Kitamura H, Tanaka Y, Yoshinari M, Kobayashi K, Chatto M, Yamashige D, Kawasaki Y, Nagashio Y, Okusaka T. Safety of biliary drainage with 6-mm metallic stent for preoperative obstructive jaundice in pancreatic cancer: PURPLE SIX STUDY. J Gastroenterol Hepatol 2024; 39:1442-1449. [PMID: 38421093 DOI: 10.1111/jgh.16524] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/13/2023] [Revised: 01/31/2024] [Accepted: 02/05/2024] [Indexed: 03/02/2024]
Abstract
BACKGROUND AND AIM The 10-mm self-expandable metal stent (SEMS) is the standard for endoscopic transpapillary biliary drainage before pancreatic cancer surgery. However, the efficacy of stents thinner than 10 mm has not been adequately validated. Therefore, we aimed to evaluate the safety of a 6-mm fully covered SEMS (FCSEMS) for distal malignant biliary obstruction (DMBO) during preoperative chemotherapy for pancreatic cancer. METHODS This was a single-arm, multicenter, prospective phase II study of endoscopic transpapillary initial biliary drainage for DMBO before pancreatic cancer surgery. The primary endpoint was stent-related adverse events, and the key secondary endpoint was the non-recurrent biliary obstruction (non-RBO) rate during the observation period for both resectable (R) and borderline resectable (BR) pancreatic cancers. RESULTS The study enrolled 33 patients, among whom 32 received the study treatment. There were 23 and 9 cases of R and BR pancreatic cancers, respectively. The technical and clinical success rates were 97.0% and 90.1%, respectively. The stent-related adverse event rate was 3.1% (n = 1, acute pancreatitis) (95% confidential interval, 0.00-16.2), which met the criteria to be considered safe. The overall non-RBO rate during the observation period (median 96 days) was 78.1% (82.6% and 66.7% for R and BR pancreatic cancer cases, respectively). CONCLUSIONS The 6-mm FCSEMS is an extremely safe metallic stent with a low stent-related adverse event rate of 3.1% for preoperative biliary drainage in pancreatic cancer. It is considered the optimal stent for preoperative biliary drainage in terms of the non-RBO rate. UMIN Clinical Trial Registry (UMIN-CTR 000041704).
Collapse
Affiliation(s)
- Shota Harai
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
- Department of Gastroenterology, University of Yamanashi Faculty of Medicine Graduate School of Medicine, Yamanashi, Japan
| | - Susumu Hijioka
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
| | - Reiko Yamada
- Department of Gastroenterology and Hepatology, Mie University Graduate School of Medicine, Mie, Japan
| | - Takeshi Ogura
- Second Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Osaka, Japan
| | - Mitsuharu Fukasawa
- Department of Gastroenterology, University of Yamanashi Faculty of Medicine Graduate School of Medicine, Yamanashi, Japan
| | - Atsushi Okuda
- Second Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Osaka, Japan
| | - Hideyuki Horike
- Department of Gastroenterology and Hepatology, Tokyo Metropolitan Tama Medical Center, Tokyo, Japan
| | - Dai Inoue
- Department of Gastroenterology and Hepatology, Tokyo Metropolitan Tama Medical Center, Tokyo, Japan
| | - Masanari Sekine
- Department of Gastroenterology, Jichi Medical University Saitama Medical Center, Saitama, Japan
| | - Yusuke Ishida
- Department of Gastroenterology and Medicine, Fukuoka University Faculty of Medicine, Fukuoka, Japan
| | - Takehiko Koga
- Department of Gastroenterology and Medicine, Fukuoka University Faculty of Medicine, Fukuoka, Japan
| | - Hidetoshi Kitamura
- Department of Gastroenterology, International University of Health and Welfare Mita Hospital, Tokyo, Japan
| | - Yasuhito Tanaka
- Department of Gastroenterology and Hepatology, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan
| | - Motohiro Yoshinari
- Department of Gastroenterology and Hepatology, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan
| | - Katsumasa Kobayashi
- Department of Gastroenterology, Tokyo Metropolitan Bokutoh Hospital, Tokyo, Japan
| | | | - Daiki Yamashige
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
| | - Yuki Kawasaki
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
| | - Yoshikuni Nagashio
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
| | - Takuji Okusaka
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
| |
Collapse
|
4
|
Nakagawa H, Takeda T, Okamoto T, Mie T, Kasuga A, Sasaki T, Ozaka M, Matsuda T, Igarashi Y, Sasahira N. Outcomes of 6-mm diameter fully covered self-expandable metal stents for preoperative biliary drainage in pancreatic cancer. DEN OPEN 2024; 4:e360. [PMID: 38601271 PMCID: PMC11004548 DOI: 10.1002/deo2.360] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/18/2024] [Revised: 03/15/2024] [Accepted: 03/24/2024] [Indexed: 04/12/2024]
Abstract
Background 10-mm self-expandable metal stents (SEMSs) are commonly used for preoperative biliary drainage in pancreatic cancer. However, smaller diameter SEMSs have attracted attention with the attempt to reduce stent-related adverse events (AEs). Methods We retrospectively analyzed consecutive borderline resectable pancreatic cancer patients who underwent neoadjuvant therapy and fully covered SEMS (FCSEMS) placement from April 2015 to May 2023. The primary outcome was stent-related non-event rate (NER), which was defined as the rate of completion of surgery without developing any preoperative events (recurrent biliary obstruction [RBO] or stent-related AEs). Secondary outcomes included stent-related AEs, causes of RBO, and cumulative incidence of RBO. Risk factors for pancreatitis, RBO, and stent migration were also examined. Results A total of 76 patients were included (6-mm group: 23; 10-mm group: 53). Stent-related NER (57% vs. 64%, p = 0.610), stent-related AEs (4% vs. 15%, p = 0.263), overall RBO rates (39% vs. 23%, p = 0.168), cumulative incidence of RBO (hazard ratio, 2.24; 95% confidence interval, 0.95-5.25; p = 0.065) were not significantly different between the two groups. Tumor involvement of the pancreatic duct was identified as a risk-reducing factor for pancreatitis, while an FCSEMS diameter of 6 mm was not identified as a risk factor for RBO and stent migration. Conclusions Stent-related NER was not significantly affected by FCSEMS diameter. Further studies are needed to confirm the usefulness of 6-mm diameter FCSEMS for preoperative biliary drainage in patients with borderline resectable pancreatic cancer.
Collapse
Affiliation(s)
- Hiroki Nakagawa
- Department of Hepato‐Biliary‐Pancreatic MedicineCancer Institute Hospital of Japanese Foundation for Cancer ResearchTokyoJapan
- Department of Internal MedicineDivision of Gastroenterology and Hepatology, Omori Medical CenterToho UniversityTokyoJapan
| | - Tsuyoshi Takeda
- Department of Hepato‐Biliary‐Pancreatic MedicineCancer Institute Hospital of Japanese Foundation for Cancer ResearchTokyoJapan
| | - Takeshi Okamoto
- Department of Hepato‐Biliary‐Pancreatic MedicineCancer Institute Hospital of Japanese Foundation for Cancer ResearchTokyoJapan
| | - Takafumi Mie
- Department of Hepato‐Biliary‐Pancreatic MedicineCancer Institute Hospital of Japanese Foundation for Cancer ResearchTokyoJapan
| | - Akiyoshi Kasuga
- Department of Hepato‐Biliary‐Pancreatic MedicineCancer Institute Hospital of Japanese Foundation for Cancer ResearchTokyoJapan
| | - Takashi Sasaki
- Department of Hepato‐Biliary‐Pancreatic MedicineCancer Institute Hospital of Japanese Foundation for Cancer ResearchTokyoJapan
| | - Masato Ozaka
- Department of Hepato‐Biliary‐Pancreatic MedicineCancer Institute Hospital of Japanese Foundation for Cancer ResearchTokyoJapan
| | - Takahisa Matsuda
- Department of Internal MedicineDivision of Gastroenterology and Hepatology, Omori Medical CenterToho UniversityTokyoJapan
| | - Yoshinori Igarashi
- Department of Internal MedicineDivision of Gastroenterology and Hepatology, Omori Medical CenterToho UniversityTokyoJapan
| | - Naoki Sasahira
- Department of Hepato‐Biliary‐Pancreatic MedicineCancer Institute Hospital of Japanese Foundation for Cancer ResearchTokyoJapan
| |
Collapse
|
5
|
Vanella G, Coluccio C, Cucchetti A, Leone R, Dell'Anna G, Giuffrida P, Abbatiello C, Binda C, Fabbri C, Arcidiacono PG. Fully covered versus partially covered self-expandable metal stents for palliation of distal malignant biliary obstruction: a systematic review and meta-analysis. Gastrointest Endosc 2024; 99:314-322.e19. [PMID: 37813199 DOI: 10.1016/j.gie.2023.10.023] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Revised: 08/28/2023] [Accepted: 10/04/2023] [Indexed: 10/11/2023]
Abstract
BACKGROUND AND AIMS Self-expandable metal stents (SEMSs) are standardly used for distal malignant biliary obstruction (dMBO). Although data suggest that covered versus uncovered SEMSs increase the time to recurrent biliary obstruction (TRBO), no data are available for fully covered (FC) versus partially covered (PC) designs. METHODS PubMed, Scopus, and Cochrane databases were screened up to January 2023 for studies concerning dMBO treated by an FC- or PC-SEMS and describing adverse events (AEs), recurrences, or TRBO for specific design subpopulations. Pooled proportions or means were calculated using a random-effects model. Several subanalyses were preplanned, including a subanalysis restricted to prospective studies and unresectable diseases. Heterogeneity and publication bias were explored. Standardized differences (d-values) were calculated between groups. RESULTS From 1290 records, 62 studies (3327 using FC-SEMSs and 2322 using PC-SEMSs) were included. FC- versus PC-SEMSs showed negligible differences in the rate of total AEs (12% vs 9.9%) and all specific AEs, including cholecystitis (2.5% vs 2.6%). In a subanalysis restricted to prospective studies and unresectable diseases, the rate of RBO was comparable between FC-SEMSs (27.3% [95% confidence interval {CI}, 23.7-31.2], I2 = 35.34%) and PC-SEMSs (25.3% [95% CI, 20.2-30.7], I2 = 85.09%), despite small differences (d-values between .186 and .216) in the rate of ingrowth (.5% vs 2.9%) favoring FC-SEMSs and migration (9.8% vs 4.3%) favoring PC-SEMSs. TRBO was shorter for FC-SEMSs (238 days [95% CI, 191-286], I2 = 63.1%) versus PC-SEMSs (369 days [95% CI, 290-449], I2 = 71.9%; d-value = .116). CONCLUSIONS Despite considerable heterogeneity and small standardized differences, PC-SEMSs consistently exhibited longer TRBO than FC-SEMSs across analyses, without any other differences in AE rates, potentially proposing PC-SEMSs as the standard comparator and TRBO as the primary outcome for future randomized studies on dMBO. (Clinical trial registration number: CRD42023393965.).
Collapse
Affiliation(s)
- Giuseppe Vanella
- Pancreatobiliary Endoscopy and Endosonography Division, Pancreas Translational and Clinical Research Centre, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
| | - Chiara Coluccio
- Gastroenterology Department, Morgagni-Pierantoni Hospital, Forlì, Italy
| | - Alessandro Cucchetti
- Gastroenterology Department, Morgagni-Pierantoni Hospital, Forlì, Italy; Pancreatobiliary Endoscopy and Endosonography Division, Alma Mater Studiorum University of Bologna, Bologna, Italy
| | - Roberto Leone
- Pancreatobiliary Endoscopy and Endosonography Division, Pancreas Translational and Clinical Research Centre, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy; International MD Program, Vita-Salute San Raffaele University, Milan, Italy
| | - Giuseppe Dell'Anna
- Pancreatobiliary Endoscopy and Endosonography Division, Pancreas Translational and Clinical Research Centre, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
| | - Paolo Giuffrida
- Gastroenterology Department, Morgagni-Pierantoni Hospital, Forlì, Italy; Section of Gastroenterology & Hepatology, Department of Health Promotion Sciences Maternal and Infant Care, Internal Medicine and Medical Specialties, PROMISE, University of Palermo, Palermo, Italy
| | - Carmela Abbatiello
- Gastroenterology Department, Morgagni-Pierantoni Hospital, Forlì, Italy; Digestive Disease Postgraduate School, University of Salerno, Italy
| | - Cecilia Binda
- Gastroenterology Department, Morgagni-Pierantoni Hospital, Forlì, Italy
| | - Carlo Fabbri
- Gastroenterology Department, Morgagni-Pierantoni Hospital, Forlì, Italy
| | - Paolo Giorgio Arcidiacono
- Pancreatobiliary Endoscopy and Endosonography Division, Pancreas Translational and Clinical Research Centre, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
| |
Collapse
|
6
|
Endo Y, Tanaka M, Kitago M, Yagi H, Abe Y, Hasegawa Y, Hori S, Nakano Y, Iwasaki E, Kitagawa Y. Comparison Between Plastic and Metallic Biliary Stent Placement for Preoperative Patients with Pancreatic Head Cancer: A Systematic Review and Meta-Analysis. Ann Surg Oncol 2024; 31:1319-1327. [PMID: 37952017 DOI: 10.1245/s10434-023-14523-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Accepted: 10/15/2023] [Indexed: 11/14/2023]
Abstract
BACKGROUND Optimal preoperative biliary drainage for patients with pancreatic cancer before pancreatoduodenectomy remains unclear. This study aimed to investigate the comparison of efficacy and safety between a metallic stent (MS) and a plastic stent (PS). METHODS Comparative studies on the use of MS and PS for pancreatic cancer before pancreatoduodenectomy were systematically searched using the MEDLINE and Web of Science databases. Pre- and postoperative data also were extracted. Random-effects meta-analyses were performed to compare post-endoscopic retrograde cholangiopancreatography (ERCP) complications as well as intra- and postoperative outcomes between the two arms of the study, and pooled odds ratios (ORs) or mean differences (MDs) were calculated with 95 percent confidence intervals (CIs). RESULTS The study analyzed 12 studies involving 683 patients. Insertion of MS was associated with a lower incidence of re-intervention (OR, 0.06; 95% CI 0.03-0.15; P < 0.001), increased post-ERCP adverse events (OR, 2.22; 95% CI 1.13-4.36; P = 0.02), and similar operation time (MD, 18.0 min; 95% CI -29.1 to 65.6 min; P = 0.46), amount of blood loss (MD, 43.0 ml; 95% CI -207.1 to 288.2 ml; P = 0.73), and surgical complication rate (OR, 0.78; 95% CI 0.53-1.15; P = 0.21). The cumulative stent patency rate after 3 months was higher in the MS group than in the PS group (70-100 % vs 30.0-45.0 %). CONCLUSION For biliary drainage in patients with pancreatic cancer during this era of multidisciplinary treatment, MS use might be the first choice because MS provides a more durable biliary drainage and a similar risk of postoperative outcomes compared with PS.
Collapse
Affiliation(s)
- Yutaka Endo
- Departments of Surgery, Keio University School of Medicine, Shinanomachi, Shinjuku, Tokyo, Japan
| | - Masayuki Tanaka
- Departments of Surgery, Keio University School of Medicine, Shinanomachi, Shinjuku, Tokyo, Japan.
| | - Minoru Kitago
- Departments of Surgery, Keio University School of Medicine, Shinanomachi, Shinjuku, Tokyo, Japan
| | - Hiroshi Yagi
- Departments of Surgery, Keio University School of Medicine, Shinanomachi, Shinjuku, Tokyo, Japan
| | - Yuta Abe
- Departments of Surgery, Keio University School of Medicine, Shinanomachi, Shinjuku, Tokyo, Japan
| | - Yasushi Hasegawa
- Departments of Surgery, Keio University School of Medicine, Shinanomachi, Shinjuku, Tokyo, Japan
| | - Shutaro Hori
- Departments of Surgery, Keio University School of Medicine, Shinanomachi, Shinjuku, Tokyo, Japan
| | - Yutaka Nakano
- Departments of Surgery, Keio University School of Medicine, Shinanomachi, Shinjuku, Tokyo, Japan
| | - Eisuke Iwasaki
- Departments of Internal Medicine, Keio University School of Medicine, Shinanomachi, Shinjuku, Tokyo, Japan
| | - Yuko Kitagawa
- Departments of Surgery, Keio University School of Medicine, Shinanomachi, Shinjuku, Tokyo, Japan
| |
Collapse
|
7
|
Ota S, Shiomi H, Nakano R, Nishimura T, Enomoto H, Iijima H. A case of delayed pancreatic fistula after covered self-expandable metallic stent deployment for pancreatic head cancer. Clin J Gastroenterol 2023; 16:303-309. [PMID: 36625993 DOI: 10.1007/s12328-023-01759-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Accepted: 01/06/2023] [Indexed: 01/11/2023]
Abstract
A 69-year-old man was referred to our hospital with obstructive jaundice. A tumor with poor contrast enhancement was found in the pancreatic head, but there was no evidence of pancreatic atrophy, irregular stenosis, or dilation of the main pancreatic duct. He was diagnosed with borderline resectable pancreatic cancer with distal malignant biliary obstruction. After plastic stent placement, serum bilirubin levels improved, and chemotherapy was started. However, he developed cholangitis; thus, the plastic stent was replaced with a covered self-expandable metallic stent. He subsequently developed a delayed pancreatic fistula due to main pancreatic duct disruption. An endoscopic nasopancreatic duct drainage tube was placed to bridge the main pancreatic duct disruption after removing the covered self-expandable metallic stent. In addition, endoscopic ultrasound-guided transmural drainage was performed for the infected fluid collection caused by the pancreatic fistula, and the clinical symptoms quickly improved. This case presents the possibility of a delayed pancreatic fistula due to self-expandable metallic stent deployment. The need for considering such delayed complications when placing self-expanding metallic stents is highlighted.
Collapse
Affiliation(s)
- Shogo Ota
- Division of Gastroenterology and Hepatobiliary and Pancreatic Diseases, Department of Internal Medicine, Hyogo Medical University, 1-1 Mukogawa-Cho, Nishinomiya, 663-8501, Japan
| | - Hideyuki Shiomi
- Division of Gastroenterology and Hepatobiliary and Pancreatic Diseases, Department of Internal Medicine, Hyogo Medical University, 1-1 Mukogawa-Cho, Nishinomiya, 663-8501, Japan.
| | - Ryota Nakano
- Division of Gastroenterology and Hepatobiliary and Pancreatic Diseases, Department of Internal Medicine, Hyogo Medical University, 1-1 Mukogawa-Cho, Nishinomiya, 663-8501, Japan
| | - Takashi Nishimura
- Division of Gastroenterology and Hepatobiliary and Pancreatic Diseases, Department of Internal Medicine, Hyogo Medical University, 1-1 Mukogawa-Cho, Nishinomiya, 663-8501, Japan
| | - Hirayuki Enomoto
- Division of Gastroenterology and Hepatobiliary and Pancreatic Diseases, Department of Internal Medicine, Hyogo Medical University, 1-1 Mukogawa-Cho, Nishinomiya, 663-8501, Japan
| | - Hiroko Iijima
- Division of Gastroenterology and Hepatobiliary and Pancreatic Diseases, Department of Internal Medicine, Hyogo Medical University, 1-1 Mukogawa-Cho, Nishinomiya, 663-8501, Japan
| |
Collapse
|
8
|
Harai S, Hijioka S, Nagashio Y, Ohba A, Maruki Y, Yamashige D, Hisada Y, Yoshinari M, Kitamura H, Maehara K, Murashima Y, Kawasaki Y, Koga T, Takeshita K, Ueno H, Kondo S, Morizane C, Fukasawa M, Sone M, Saito Y, Enomoto N, Okusaka T. Comparison of 6-mm and 10-mm-diameter, fully-covered, self-expandable metallic stents for distal malignant biliary obstruction. Endosc Int Open 2023; 11:E340-E348. [PMID: 37077662 PMCID: PMC10110359 DOI: 10.1055/a-2039-4316] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/17/2022] [Accepted: 01/31/2023] [Indexed: 04/21/2023] Open
Abstract
Abstract
Background and study aims For distal malignant biliary obstruction, self-expandable metallic stents (SEMSs) have a larger inner diameter compared to plastic stents, which prolongs time to recurrent biliary obstruction (TRBO), although stent-related complications are still a problem. This study aimed to compare the outcomes between using 10– and 6-mm-diameter fully-covered SEMS (FCSEMS) for distal malignant biliary obstruction.
Patients and methods This single-center, retrospective study included patients with 10-mm or 6-mm-diameter FCSEMS to treat distal malignant biliary obstruction. Clinical success, stent-related adverse events (AEs), cumulative incidence of RBO, factors involved in stent-related AEs, and factors involved in RBO were evaluated.
Results There were 243 eligible cases between October 2017 and December 2021. The cumulative incidence of RBO did not differ significantly between the 10-mm and 6-mm groups. Stent-related AEs occurred in 31.6 % and 11.4 % of patients between the 10-mm and 6-mm groups, respectively (P < 0.01). Pancreatitis occurred in 10.5 % and 3.6 % (P = 0.04) and cholecystitis occurred in 11.8 % and 3.0 % of patients (P = 0.03) in the 10-mm and 6-mm groups, respectively. In multivariate analysis, the 6-mm stent was extracted as a factor linked to a reduced risk of AEs, but not as a risk factor of RBO.
Conclusions The 6-mm-diameter FCSEMS for distal malignant biliary obstruction is a well-balanced stent with a cumulative incidence of RBO compatible to that of the 10-mm-diameter FCSEMS and fewer stent-related AEs.
Collapse
Affiliation(s)
- Shota Harai
- National Cancer Center Japan, Department of Hepatobiliary and Pancreatic Oncology, Tokyo, Japan
- University of Yamanashi, Faculty of Medicine Graduate School of Medicine, First Department of Internal Medicine, Yamanashi, Japan
| | - Susumu Hijioka
- National Cancer Center Japan, Department of Hepatobiliary and Pancreatic Oncology, Tokyo, Japan
| | - Yoshikuni Nagashio
- National Cancer Center Japan, Department of Hepatobiliary and Pancreatic Oncology, Tokyo, Japan
| | - Akihiro Ohba
- National Cancer Center Japan, Department of Hepatobiliary and Pancreatic Oncology, Tokyo, Japan
| | - Yuta Maruki
- National Cancer Center Japan, Department of Hepatobiliary and Pancreatic Oncology, Tokyo, Japan
| | - Daiki Yamashige
- National Cancer Center Japan, Department of Hepatobiliary and Pancreatic Oncology, Tokyo, Japan
| | - Yuya Hisada
- National Cancer Center Japan, Department of Hepatobiliary and Pancreatic Oncology, Tokyo, Japan
| | - Motohiro Yoshinari
- National Cancer Center Japan, Department of Hepatobiliary and Pancreatic Oncology, Tokyo, Japan
| | - Hidetoshi Kitamura
- National Cancer Center Japan, Department of Hepatobiliary and Pancreatic Oncology, Tokyo, Japan
| | - Kosuke Maehara
- National Cancer Center Japan, Department of Hepatobiliary and Pancreatic Oncology, Tokyo, Japan
| | - Yumi Murashima
- National Cancer Center Japan, Department of Hepatobiliary and Pancreatic Oncology, Tokyo, Japan
| | - Yuki Kawasaki
- National Cancer Center Japan, Department of Hepatobiliary and Pancreatic Oncology, Tokyo, Japan
| | - Takehiko Koga
- National Cancer Center Japan, Department of Hepatobiliary and Pancreatic Oncology, Tokyo, Japan
| | - Kotaro Takeshita
- National Cancer Center Japan, Department of Hepatobiliary and Pancreatic Oncology, Tokyo, Japan
| | - Hideki Ueno
- National Cancer Center Japan, Department of Hepatobiliary and Pancreatic Oncology, Tokyo, Japan
| | - Shunsuke Kondo
- National Cancer Center Japan, Department of Hepatobiliary and Pancreatic Oncology, Tokyo, Japan
| | - Chigusa Morizane
- National Cancer Center Japan, Department of Hepatobiliary and Pancreatic Oncology, Tokyo, Japan
| | - Mitsuharu Fukasawa
- University of Yamanashi, Faculty of Medicine Graduate School of Medicine, First Department of Internal Medicine, Yamanashi, Japan
| | - Miyuki Sone
- National Cancer Center Japan, Department of Diagnostic Radiology, Tokyo, Japan
| | - Yutaka Saito
- National Cancer Center Japan, Department of Endoscopy, Tokyo, Japan
| | - Nobuyuki Enomoto
- University of Yamanashi, Faculty of Medicine Graduate School of Medicine, First Department of Internal Medicine, Yamanashi, Japan
| | - Takuji Okusaka
- National Cancer Center Japan, Department of Hepatobiliary and Pancreatic Oncology, Tokyo, Japan
| |
Collapse
|