1
|
Vinyes-Nadal M, Masbou J, Kümmel S, Gehre M, Imfeld G, Otero N, Torrentó C. Novel extraction methods and compound-specific isotope analysis of methoxychlor in environmental water and aquifer slurry samples. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 931:172858. [PMID: 38714260 DOI: 10.1016/j.scitotenv.2024.172858] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/26/2024] [Revised: 04/26/2024] [Accepted: 04/26/2024] [Indexed: 05/09/2024]
Abstract
Multi-element compound-specific stable isotope analysis (ME-CSIA) allows monitoring the environmental behavior and transformation of most common and persistent contaminants. Recent advancements in analytical techniques have extended the applicability of ME-CSIA to organic micropollutants, including pesticides. Nevertheless, the application of this methodology remains unexplored concerning harmful insecticides such as methoxychlor, a polar organochlorine pesticide usually detected in soil and groundwater. This study introduces methods for dual carbon and chlorine compound-specific stable isotope analysis (δ13C-CSIA and δ37Cl-CSIA) of both methoxychlor and its metabolite, methoxychlor olefin, with a sensitivity down to 10 and 100 mg/L, and a precision lower than 0.3 and 0.5 ‰ for carbon and chlorine CSIA, respectively. Additionally, three extraction and preconcentration techniques suitable for ME-CSIA of the target pesticides at environmentally relevant concentrations were also developed. Solid-phase extraction (SPE) and liquid-solid extraction (LSE) effectively extracted methoxychlor (107 ± 27 % and 87 ± 13 %, respectively) and its metabolite (91 ± 27 % and 106 ± 14 %, respectively) from water and aquifer slurry samples, respectively, with high accuracy (Δδ13C and Δδ37Cl ≤ ± 1 ‰). Combining CSIA with polar organic chemical integrative samplers (POCISs) for the extraction of methoxychlor and methoxychlor olefin from water samples resulted in insignificant fractionation for POCIS-CSIA (Δδ13C ≤ ± 1 ‰). A relevant sorption of methoxychlor was detected within the polyethersulfones membranes of the POCISs resulting in temporary carbon isotope fractionation depending on the sorbed mass fraction during the first deployment days. This highlights the critical role of the interactions of polar analytes with POCIS sorbents and membranes in the performance of this method. Altogether, this study proposes a proof of concept for ME-CSIA of methoxychlor and its metabolites, opening the door for future investigations of their sources and transformation processes in contaminated sites.
Collapse
Affiliation(s)
- Martí Vinyes-Nadal
- Grup MAiMA, SGR Mineralogia Aplicada, Geoquímica i Hidrogeologia (MAGH), Departament de Mineralogia, Petrologia i Geologia Aplicada, Facultat de Ciències de la Terra, Institut de Recerca de l'Aigua (IdRA), Universitat de Barcelona (UB), Martí i Franquès s/n, 08028 Barcelona, Spain.
| | - Jérémy Masbou
- Université de Strasbourg, CNRS/ENGEES, ITES UMR 7063, Institut Terre et Environnement de Strasbourg, Strasbourg, France.
| | - Steffen Kümmel
- Department of Technical Biogeochemistry, Helmholtz Centre for Environmental Research - UFZ, Permoserstraße 15, Leipzig 04318, Germany.
| | - Matthias Gehre
- Department of Technical Biogeochemistry, Helmholtz Centre for Environmental Research - UFZ, Permoserstraße 15, Leipzig 04318, Germany.
| | - Gwenaël Imfeld
- Université de Strasbourg, CNRS/ENGEES, ITES UMR 7063, Institut Terre et Environnement de Strasbourg, Strasbourg, France.
| | - Neus Otero
- Grup MAiMA, SGR Mineralogia Aplicada, Geoquímica i Hidrogeologia (MAGH), Departament de Mineralogia, Petrologia i Geologia Aplicada, Facultat de Ciències de la Terra, Institut de Recerca de l'Aigua (IdRA), Universitat de Barcelona (UB), Martí i Franquès s/n, 08028 Barcelona, Spain; Serra Húnter Fellowship, Generalitat de Catalunya, Spain.
| | - Clara Torrentó
- Grup MAiMA, SGR Mineralogia Aplicada, Geoquímica i Hidrogeologia (MAGH), Departament de Mineralogia, Petrologia i Geologia Aplicada, Facultat de Ciències de la Terra, Institut de Recerca de l'Aigua (IdRA), Universitat de Barcelona (UB), Martí i Franquès s/n, 08028 Barcelona, Spain; Serra Húnter Fellowship, Generalitat de Catalunya, Spain.
| |
Collapse
|
2
|
Suchana S, Edwards E, Mack EE, Lomheim L, Melo N, Gavazza S, Passeport E. Compatibility of polar organic chemical integrative sampler (POCIS) with compound specific isotope analysis (CSIA) of substituted chlorobenzenes. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 906:167628. [PMID: 37804973 DOI: 10.1016/j.scitotenv.2023.167628] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 10/03/2023] [Accepted: 10/04/2023] [Indexed: 10/09/2023]
Abstract
Compound specific isotope analysis (CSIA) is a powerful technique to demonstrate in situ degradation of traditional groundwater contaminants when concentrations are typically in the mg/L range. Currently, an efficient preconcentration method is lacking to expand CSIA to low aqueous concentration environmental samples. Specially for the H- and N-CSIA of heteroatom-bearing non-traditional compounds, the CSIA analytical detection limits are significantly higher than that of the C-CSIA. This work demonstrates the compatibility of polar organic chemical integrative sampler (POCIS) with C-, H-, and N-CSIA using four nitro- and amino-substituted chlorobenzenes that are common industrial feedstocks for numerous applications and are commonly detected in the environment at mg/L to μg/L range. Using lab experiments, we showed isotopic equilibrium in POCIS was achieved after 30 days with either a negligible (<0.5 ‰) or a constant shift for C (<1 ‰) and N (<2 ‰). Similar negligible (<5 ‰) or constant shift (<20 ‰) was evident for H isotope except for 3,4-dichloroaniline. The method quantification limits for the combined sorbent and membrane of one POCIS were comparable to that of the solid phase extraction (SPE) using 10 L water. Next, we demonstrated the field applicability of POCIS for C- and N-CSIA after a 60-day deployment in a pilot constructed wetland by showing <1 ‰ difference between the δ13C and δ15N obtained from POCIS and SPE. Finally, we evaluated whether the biofilm development on POCIS membrane could affect the isotope signature of the sampled compounds during field deployment. Although a diverse microbial community was identified on the membrane after a 60-day deployment, we did not observe significant isotope fractionation. This was likely due to either slower diffusion in the biofilm or microbial degradation of the sampled compounds. This work demonstrates the potential of using POCIS-CSIA as a simple, fast, and sensitive method for low-concentration contaminants, such as pesticides, pharmaceuticals, and flame-retardants.
Collapse
Affiliation(s)
- Shamsunnahar Suchana
- Department of Civil & Mineral Engineering, University of Toronto, 35 St. George Street, Toronto, Ontario M5S 1A4, Canada
| | - Elizabeth Edwards
- Department of Chemical Engineering & Applied Chemistry, University of Toronto, 200 College Street, Toronto, Ontario M5S 3E5, Canada
| | - E Erin Mack
- Corteva Environmental Remediation, Corteva Agriscience, Wilmington, DE 19805, USA
| | - Line Lomheim
- Department of Chemical Engineering & Applied Chemistry, University of Toronto, 200 College Street, Toronto, Ontario M5S 3E5, Canada
| | - Natanna Melo
- Laboratório de Saneamento Ambiental, Departamento de Engenharia Civil e Ambiental, Universidade Federal de Pernambuco, Recife, PE 50740-530, Brazil
| | - Sávia Gavazza
- Laboratório de Saneamento Ambiental, Departamento de Engenharia Civil e Ambiental, Universidade Federal de Pernambuco, Recife, PE 50740-530, Brazil
| | - Elodie Passeport
- Department of Civil & Mineral Engineering, University of Toronto, 35 St. George Street, Toronto, Ontario M5S 1A4, Canada; Department of Chemical Engineering & Applied Chemistry, University of Toronto, 200 College Street, Toronto, Ontario M5S 3E5, Canada.
| |
Collapse
|
3
|
Strehse JS, Bünning TH, Koschorreck J, Künitzer A, Maser E. Long-Term Trends for Blue Mussels from the German Environmental Specimen Bank Show First Evidence of Munition Contaminants Uptake. TOXICS 2023; 11:347. [PMID: 37112574 PMCID: PMC10142797 DOI: 10.3390/toxics11040347] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Revised: 03/20/2023] [Accepted: 03/31/2023] [Indexed: 06/19/2023]
Abstract
Submerged munitions are present in marine waters across the globe. They contain energetic compounds (ECs), such as TNT and metabolites thereof, which are considered carcinogenic, exhibit toxic effects in marine organisms, and may affect human health. The aim of this study was to investigate the occurrence of ECs and their trends in blue mussels from the annual collections of the German Environmental Specimen Bank sampled over the last 30 years at three different locations along the coastline of the Baltic and North Sea. Samples were analyzed by GC-MS/MS for 1,3-dinitrobenzene (1,3-DNB), 2,4-dinitrotoluene (2,4-DNT), 2,4,6-trinitrotoluene (TNT), 2-amino-4,6-dinitrotoluene (2-ADNT), and 4-amino-2,6-dinitrotoluene (4-ADNT). The first signals indicating trace levels of 1,3-DNB were observed in samples from 1999 and 2000. ECs were also found below the limit of detection (LoD) in subsequent years. From 2012 onwards, signals just above the LoD were detected. The highest signal intensities of 2-ADNT and 4-ADNT, just below the LoQ (0.14 ng/g d.w. and 0.17 ng/g d.w., respectively), were measured in 2019 and 2020. This study clearly shows that corroding submerged munitions are gradually releasing ECs into the waters that can be detected in randomly sampled blue mussels, even though the concentrations measured are still in the non-quantifiable trace range.
Collapse
Affiliation(s)
- Jennifer Susanne Strehse
- Institute of Toxicology and Pharmacology for Natural Scientists, University Medical School Schleswig-Holstein, Brunswiker Straße 10, 24105 Kiel, Germany (E.M.)
| | - Tobias Hartwig Bünning
- Institute of Toxicology and Pharmacology for Natural Scientists, University Medical School Schleswig-Holstein, Brunswiker Straße 10, 24105 Kiel, Germany (E.M.)
| | - Jan Koschorreck
- German Environment Agency, Wörlitzer Platz 1, 06844 Dessau, Germany
| | - Anita Künitzer
- German Environment Agency, Wörlitzer Platz 1, 06844 Dessau, Germany
| | - Edmund Maser
- Institute of Toxicology and Pharmacology for Natural Scientists, University Medical School Schleswig-Holstein, Brunswiker Straße 10, 24105 Kiel, Germany (E.M.)
| |
Collapse
|
4
|
Noro K, Endo S, Inoue D, Suzuki N, Kameoka H, Ono J, Nakamura S, Yabuki Y. Development of a New Polar Organic Chemical Integrative Sampler for 1,4-dioxane Using Silicone Membrane as a Diffusion Barrier. ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY 2023; 42:296-302. [PMID: 36349960 DOI: 10.1002/etc.5518] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Revised: 10/09/2022] [Accepted: 11/07/2022] [Indexed: 06/16/2023]
Abstract
Efficient monitoring methods must be developed for 1,4-dioxane, which is suspected to be carcinogenic to humans and is highly mobile in aquatic environments. In this regard, polar organic chemical integrative samplers (POCIS) have been utilized extensively as passive samplers for determining time-weighted average concentrations of hydrophilic organic compounds. However, POCIS are difficult to apply to extremely hydrophilic known organic compounds with negative log octanol-water partition coefficient (Kow ) values due to their limited kinetic sampling time. Using an activated carbon-based sorbent with a high adsorption capacity and a bilayer of silicone and polyethersulfone membranes that inhibit mass transfer to the sorbent, we developed a POCIS device to measure 1,4-dioxane (log Kow -0.27) in the present study. Permeation and field calibration tests demonstrated that the use of silicone membranes effectively reduces the water-to-sorbent mass transfer rate. The sampling rate and kinetic sampling period determined by field calibration tests were 1.4 ml day-1 and >14 days, respectively. Finally, the developed POCIS device was applied to a landfill treatment plant to determine the 1,4-dioxane concentrations. Environ Toxicol Chem 2023;42:296-302. © 2022 SETAC.
Collapse
Affiliation(s)
- Kazushi Noro
- School of Food and Nutritional Sciences, University of Shizuoka, Shizuoka, Japan
- Research Institute of Environment, Agriculture, and Fisheries, Osaka, Japan
| | - Satoshi Endo
- Center for Health and Environmental Risk Research, National Institute for Environmental Studies, Onogawa, Ibaraki, Japan
| | - Daisuke Inoue
- Division of Sustainable Energy and Environmental Engineering, Osaka University, Suita, Osaka, Japan
| | - Natsumi Suzuki
- Faculty of Engineering, Osaka City University, Sumiyoshi-ku, Osaka, Japan
| | - Hiroshi Kameoka
- Research Institute of Environment, Agriculture, and Fisheries, Osaka, Japan
| | - Junko Ono
- Research Institute of Environment, Agriculture, and Fisheries, Osaka, Japan
| | - Satoshi Nakamura
- Research Institute of Environment, Agriculture, and Fisheries, Osaka, Japan
| | - Yoshinori Yabuki
- Research Institute of Environment, Agriculture, and Fisheries, Osaka, Japan
| |
Collapse
|
5
|
Allinson M, Cassidy M, Kadokami K, Besley CH. In situ calibration of passive sampling methods for urban micropollutants using targeted multiresidue GC and LC screening systems. CHEMOSPHERE 2023; 311:136997. [PMID: 36309053 DOI: 10.1016/j.chemosphere.2022.136997] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/08/2022] [Revised: 10/16/2022] [Accepted: 10/21/2022] [Indexed: 06/16/2023]
Abstract
In this study, ChemcatcherTM (CC) and Polar Organic Chemical Integrative Samplers (POCIS) passive samplers were chosen to investigate trace organic chemical residues in urban streams of the megacity of Sydney, Australia. In situ calibration with these passive samplers investigated 1392 organic chemicals. Six sets of CC passive samplers fitted with SDB-XC or SDB-RPS disks and six POCIS containing Oasis HLB sorbent were deployed at three sites. Every week for six weeks across three deployments, composite water samples were retrieved from autosamplers, along with one set of CC/POCIS passive samplers. Samples were analysed by Automated Identification and Quantification System (AIQS) GC/MS or LC/QTOF-MS database methods with 254 chemicals detected. The most frequently detected compounds under GC/MS analysis were aliphatic, pesticides, phenols, PAHs, sterols and fatty acid methyl esters while from LC/QTOF-MS analysis these were pesticides, pharmaceuticals, and personal care products. Sampling rates (Rs) ranged between <0.001 - 0.132 L day-1 (CC SDB-XC, 18 chemicals), <0.001 - 0.291 L day-1 (CC SDB-RPS, 28 chemicals), and <0.001 - 0.576 L day-1 (POCIS Oasis HLB, 30 chemicals). Assessment of deployment duration indicated that about half of the chemicals that were continuously detected across all deployment weeks had maximal simple linear regression R2 values at four weeks for CC SDB-RPS (seven of 13 chemicals) and at three weeks for POCIS Oasis HLB (seven of 14 chemicals). Where ranges of Rs recorded from the estuarine site were able to be compared to ranges of Rs from one or both freshwater sites, only tributyl phosphate had a higher range of Rs out of 21 possible chemical comparisons, and suggested salinity was an unlikely influence on Rs. Whereas relatively higher rainfall of the third round of deployment aligned with higher Rs across the estuarine and freshwater sites for CC SDB-RPS and POCIS for nearly all possible comparisons.
Collapse
Affiliation(s)
- M Allinson
- Department of Chemical Engineering, The University of Melbourne, Melbourne, Australia
| | - M Cassidy
- Wastewater Product, Sydney Water, 1 Smith Street, Parramatta, NSW, 2150, Australia
| | - K Kadokami
- Institute of Environmental Science and Technology, The University of Kitakyushu, Japan
| | - C H Besley
- Monitoring, Design and Reporting, Sydney Water, 1 Smith Street, Parramatta, NSW, 2150, Australia.
| |
Collapse
|
6
|
MacKeown H, Benedetti B, Scapuzzi C, Di Carro M, Magi E. A Review on Polyethersulfone Membranes in Polar Organic Chemical Integrative Samplers: Preparation, Characterization and Innovation. Crit Rev Anal Chem 2022:1-17. [PMID: 36263980 DOI: 10.1080/10408347.2022.2131374] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
The membranes in polar organic chemical integrative samplers (POCIS) enclose the receiving sorbent and protect it from coming into direct contact with the environmental matrix. They have a crucial role in extending the kinetic regime of contaminant uptake, by slowing down their diffusion between the water phase and the receiving phase. The drive to improve passive sampling requires membranes with better design and enhanced performances. In this review, the preparation of standard polyethersulfone (PES) membranes for POCIS is presented, as well as methods to evaluate their composition, morphology, structure, and performance. Generally, only supplier-related morphological and structural data are provided, such as membrane type, thickness, surface area, and pore diameter. The issues related to the use of PES membranes in POCIS applications are exposed. Finally, alternative membranes to PES in POCIS are also discussed, although no better membrane has yet been developed. This review highlights the urge for more membrane characterization details and a better comprehension of the mechanisms which underlay their behavior and performance, to improve membrane selection and optimize passive sampler development.
Collapse
Affiliation(s)
- Henry MacKeown
- Department of Chemistry and Industrial Chemistry, University of Genoa, Genoa, Italy
| | - Barbara Benedetti
- Department of Chemistry and Industrial Chemistry, University of Genoa, Genoa, Italy
| | - Chiara Scapuzzi
- Department of Chemistry and Industrial Chemistry, University of Genoa, Genoa, Italy
| | - Marina Di Carro
- Department of Chemistry and Industrial Chemistry, University of Genoa, Genoa, Italy
| | - Emanuele Magi
- Department of Chemistry and Industrial Chemistry, University of Genoa, Genoa, Italy
| |
Collapse
|
7
|
Wang P, Challis JK, He ZX, Wong CS, Zeng EY. Effects of biofouling on the uptake of perfluorinated alkyl acids by organic-diffusive gradients in thin films passive samplers. ENVIRONMENTAL SCIENCE. PROCESSES & IMPACTS 2022; 24:242-251. [PMID: 35015011 DOI: 10.1039/d1em00436k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
While organic-diffusive gradients in thin films (o-DGT) passive samplers have been used to assess organic contaminants in water, the effects of biofouling on accurate analyte quantification by o-DGT are poorly understood. We evaluated the effects of biofouling on the uptake of six common perfluoroalkyl substances (PFAS) using a previously developed polyacrylamide-WAX (weak anion exchange) o-DGT without a filter membrane. Linear uptake (R2 > 0.91) over 21 days was observed in fouled samplers. The measured sampling rates (Rs) and accumulated masses of PFAS in pre-fouled o-DGT were significantly lower (p < 0.05, 20-39% relative error) than in control-fouled samplers. However, compared to clean o-DGT (no biofouling), the Rs of most PFAS in control-fouled samplers (i.e., those with clean diffusive and binding gels initially) were not affected by biofouling. Under flowing (∼5.8 cm s-1) and static conditions, the measured diffusive boundary layer (DBL) thicknesses for clean o-DGT were 0.016 and 0.082 cm, respectively, whereas the effective in situ biofilm thicknesses for fouled o-DGT were 0.018 and 0.14 cm, respectively. These results suggest that biofilm growth does not have significant effects on target PFAS sampling by o-DGT under typical flowing conditions (≥2 cm s-1). However, rapid surface growth of biofilm on o-DGT deployed in quiescent waters over long periods of time may exacerbate the adverse effects of biofilms, necessitating the estimation of biofilm thickness in situ. This study provides new insights for evaluating the capability of o-DGT samplers when biofilm growth can be significant.
Collapse
Affiliation(s)
- Po Wang
- Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou 511443, China.
| | - Jonathan K Challis
- Toxicology Centre, University of Saskatchewan, Saskatoon, SK S7N 5B3, Canada
| | - Zi-Xuan He
- Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou 511443, China.
| | - Charles S Wong
- Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou 511443, China.
- Southern California Coastal Water Research Project Authority, Costa Mesa CA 92626, USA
| | - Eddy Y Zeng
- Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou 511443, China.
| |
Collapse
|
8
|
Rosen G, Lotufo GR, Belden JB, George RD. Environmental Characterization of Underwater Munitions Constituents at a Former Military Training Range. ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY 2022; 41:275-286. [PMID: 33978266 DOI: 10.1002/etc.5112] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2021] [Revised: 03/31/2021] [Accepted: 05/03/2021] [Indexed: 05/27/2023]
Abstract
As a result of military activities, unexploded ordnance and discarded military munitions are present in underwater environments, which has resulted in the release of munitions constituents including the high explosives 2,4,6-trinitrotoluene (TNT) and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX), along with their primary degradation products, to the water column and adjacent sediments. The present study focused on the characterization of underwater exposure and concentrations of energetics such as TNT and RDX at the former Vieques Naval Training Range at Bahia Salina del Sur (Vieques, Puerto Rico, USA), a bay with documented high incidence of munitions. In situ passive sampling using polar organic chemical integrative samplers (POCIS) was used for the detection and quantification of constituents in water at target locations approximately 15 to 30 cm from 15 individual potentially leaking munitions, and also at 15 unbiased locations approximately evenly spaced across the Bay. For comparison with POCIS-derived concentrations, grab samples were taken at the POCIS target locations. The POCIS-derived and averaged grab samples agreed within a factor of 3. When detected, munitions constituent concentrations (primarily TNT and RDX) were observed at ultratrace concentrations (as low as 4 ng/L for RDX), except 30 cm from one General Purpose bomb where the TNT concentration was 5.3 µg/L, indicating that low-level contamination exists at Bahia Salina del Sur on a very localized scale despite the relatively high density of munitions, similar to previously reported results for other munitions sites around the world. Sediment and porewater sampled at 4 stations where munitions constituents were detected in the water column had concentrations below detection (approximately 5 µg/kg and 5 ng/L, respectively), suggesting that the sediment was not a sink for these constituents at those locations. Environ Toxicol Chem 2022;41:275-286. © 2021 SETAC. This article has been contributed to by US Government employees and their work is in the public domain in the USA.
Collapse
Affiliation(s)
- Gunther Rosen
- Naval Information Warfare Center Pacific, San Diego, California, USA
| | - Guilherme R Lotufo
- US Army Engineer Research and Development Center, Vicksburg, Mississippi, USA
| | - Jason B Belden
- Department of Integrative Biology, Oklahoma State University, Stillwater, Oklahoma, USA
| | - Robert D George
- Naval Information Warfare Center Pacific, San Diego, California, USA
| |
Collapse
|
9
|
Noro K, Vermeirssen ELM, Banno A, Ono J, Yabuki Y. Comparative Evaluation of the Polar Organic Chemical Integrative Sampler in Two Types of Validation Systems Simulating Peak Concentration Events. ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY 2021; 40:3010-3018. [PMID: 34506633 DOI: 10.1002/etc.5204] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Revised: 07/12/2021] [Accepted: 09/02/2021] [Indexed: 06/13/2023]
Abstract
Polar organic chemical integrative sampler (POCIS) devices have been suggested for measuring time-weighted averages (TWAs) of contaminant concentrations resulting from chemical leak accidents in aquatic environments. However, the response of the POCIS device in the emergency condition in natural water remains unclear. The response of the POCIS device to contaminant fluctuation was investigated using a chamber test with tap water and a channel test with natural water. The fluctuation in the chamber and the channel simulated the condition of river water under a chemical leak scenario (maximum concentration: 1-10 μg L-1 , half-life: 1 day). The target chemicals were neonicotinoid pesticides (dinotefuran, clothianidin, thiamethoxam, imidacloprid, acetamiprid, and thiacloprid) and bisphenol A. The ratio of the POCIS measured value to the TWA values of grab samplings (POCIS/TWA) for the channel test (temperature: 15 °C, flow velocity: 15 cm s-1 ) ranged from 61% (clothianidin) to 133% (thiacloprid). The results indicated that the POCIS device could be effectively used as a monitoring device in an aquatic environment under the chemical leak scenario over a time period of more than14 days. In addition, the POCIS/TWA ratios obtained from the chamber test and the channel test were in the range of 50-150%. Thus, the chamber test could be used to evaluate the POCIS device at a low cost. Environ Toxicol Chem 2021;40:3010-3018. © 2021 SETAC.
Collapse
Affiliation(s)
- Kazushi Noro
- Research Institute of Environment, Agriculture and Fisheries, Osaka Prefecture, Habikino, Osaka, Japan
| | | | - Arisa Banno
- Research Institute of Environment, Agriculture and Fisheries, Osaka Prefecture, Habikino, Osaka, Japan
| | - Junko Ono
- Research Institute of Environment, Agriculture and Fisheries, Osaka Prefecture, Habikino, Osaka, Japan
| | - Yoshinori Yabuki
- Research Institute of Environment, Agriculture and Fisheries, Osaka Prefecture, Habikino, Osaka, Japan
| |
Collapse
|
10
|
Burgess RM, Grossman S, Ball G, Kady T, Sprenger M, Nevshehirlian S. Evaluating sedimentary PAH bioavailability based on equilibrium partitioning and passive sampling at the Dover Gas Light Superfund Site (Dover, Delaware, USA). INTEGRATED ENVIRONMENTAL ASSESSMENT AND MANAGEMENT 2021; 17:1215-1228. [PMID: 33710767 PMCID: PMC8823283 DOI: 10.1002/ieam.4409] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/25/2020] [Revised: 12/23/2020] [Accepted: 03/07/2021] [Indexed: 06/12/2023]
Abstract
From 1859 to 1948, the Dover Gas Light plant produced combustible gas for industrial, commercial, and residential applications using pine resin, coking coal, oil, and wood, and finally, a coal-gas process. Waste coal tar was discharged into the St. Jones River in Dover, Delaware (USA), via a ditch and culvert and, following plant closure in the 1940s, through groundwater flow from structures buried on the site. By the end of the 20th century, polycyclic aromatic hydrocarbon (PAH) contamination of the sediments in the St. Jones River was suspected to have occurred, and state and federal agencies initiated environmental assessments of the newly designated Superfund site. The current study investigated the spatial distributions of total PAHs in St. Jones River sediments adjacent to the site and evaluated their bioavailability. In 2017, 34 sediment cores were collected, sectioned, and analyzed using an on-site fluorometric screening technology indicating total PAH sediment concentrations ranging from 0.1 to 15 000 mg/kg (wet). A subset of cores involving 20 samples of various depths was selected and further analyzed by conventional GC/MS analysis for 16 parent PAHs. In addition, a 34-day in situ deployment of polyethylene passive samplers was performed to measure vertical bioavailability profiles of parent PAHs in sediments at three locations and overlying waters at four stations. Freely dissolved concentrations (C free ) of total PAHs were estimated based on equilibrium partitioning (EqP) of the GC/MS results and the passive sampling findings. C free values were used to calculate acute and chronic toxic units ranging from 1.4 to 56, based on EqP and 1.3 to 15 based on passive sampling. For six samples where comparative data were available, EqP calculations overestimated bioavailability by < 2- to 54-fold. Combining rapid field measurements with more accurate analyses of sediment concentrations and bioavailability in a tiered framework supported a time-efficient and cost-effective site investigation. Integr Environ Assess Manag 2021;17:1215-1228. © Published 2021. This article is a U.S. Government work and is in the public domain in the USA.
Collapse
Affiliation(s)
- Robert M Burgess
- US EPA ORD, CEMM, Atlantic Coastal Environmental Sciences Division, Narragansett, Rhode Island, USA
| | - Scott Grossman
- US EPA OLEM, OSRTI, Environmental Response Team, Edison, New Jersey, USA
| | - Gerald Ball
- US EPA OLEM, OSRTI, Environmental Response Team, Edison, New Jersey, USA
| | - Thomas Kady
- US EPA OLEM, OSRTI, Environmental Response Team, Edison, New Jersey, USA
| | - Mark Sprenger
- US EPA OLEM, OSRTI, Environmental Response Team, Edison, New Jersey, USA
| | | |
Collapse
|
11
|
Hahn RZ, Augusto do Nascimento C, Linden R. Evaluation of Illicit Drug Consumption by Wastewater Analysis Using Polar Organic Chemical Integrative Sampler as a Monitoring Tool. Front Chem 2021; 9:596875. [PMID: 33859973 PMCID: PMC8042236 DOI: 10.3389/fchem.2021.596875] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2020] [Accepted: 01/25/2021] [Indexed: 11/16/2022] Open
Abstract
Illicit drug abuse is a worldwide social and health problem, and monitoring illicit drug use is of paramount importance in the context of public policies. It is already known that relevant epidemiologic information can be obtained from the analysis of urban residual waters. This approach, named wastewater-based epidemiology (WBE), is based on the measurement of specific markers, resulting from human biotransformation of the target drugs, as indicators of the consumption of the compounds by the population served by the wastewater treatment installation under investigation. Drug consumption estimation based on WBE requires sewage sampling strategies that express the concentrations along the whole time period of time. To this end, the most common approach is the use of automatic composite samplers. However, this active sampling procedure is costly, especially for long-term studies and in limited-resources settings. An alternative, cost-effective, sampling strategy is the use of passive samplers, like the polar organic chemical integrative sampler (POCIS). POCIS sampling has already been applied to the estimation of exposure to pharmaceuticals, pesticides, and some drugs of abuse, and some studies evaluated the comparative performances of POCIS and automatic composite samplers. In this context, this manuscript aims to review the most important biomarkers of drugs of abuse consumption in wastewater, the fundamentals of POCIS sampling in WBE, the previous application of POCIS for WBE of drugs of abuse, and to discuss the advantages and disadvantages of POCIS sampling, in comparison with other strategies used in WBE. POCIS sampling is an effective strategy to obtain a representative overview of biomarker concentrations in sewage over time, with a small number of analyzed samples, increased detection limits, with lower costs than active sampling. Just a few studies applied POCIS sampling for WBE of drugs of abuse, but the available data support the use of POCIS as a valuable tool for the long-term monitoring of the consumption of certain drugs within a defined population, particularly in limited-resources settings.
Collapse
Affiliation(s)
- Roberta Zilles Hahn
- Laboratory of Analytical Toxicology, Universidade Feevale, Novo Hamburgo, Brazil
| | | | - Rafael Linden
- Laboratory of Analytical Toxicology, Universidade Feevale, Novo Hamburgo, Brazil.,National Institute of Forensic Science and Technology (INCT Forense), Porto Alegre, Brazil
| |
Collapse
|
12
|
Sampling Rate of Polar Organic Chemical Integrative Sampler (POCIS): Influence Factors and Calibration Methods. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10165548] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
As a passive sampling device, the polar organic chemical integrative sampler (POCIS) has the characteristics of simple operation, safety, and reliability for assessing the occurrence and risk of persistent and emerging trace organic pollutants. The POCIS, allowing for the determination of time-weighted average (TWA) concentration of polar organic chemicals, exhibits good application prospects in aquatic environments. Before deploying the device in water, the sampling rate (Rs), which is a key parameter for characterizing pollutant enrichment, should be determined and calibrated accurately. However, the Rs values strongly depend on experimental hydrodynamic conditions. This paper provides an overview of the current situation of the POCIS for environmental monitoring of organic pollutants in an aquatic system. The principle and theory of the POCIS are outlined. In particular, the effect factors such as the ambient conditions, pollutant properties, and device features on the Rs are analyzed in detail from aspects of impact dependence and mechanisms. The calibration methods of the Rs under laboratory and in situ conditions are summarized. This review offers supplementary information on comprehensive understanding of mechanism and application of the POCIS. Nevertheless, the Rs were impacted by a combined effect of solute–sorbent–membrane–solution, and the influence extent of each variable was still unclear. On this basis, the ongoing challenges are proposed for the future application of the POCIS in the actual environment, for instance, the need for this device to be improved in terms of quantitative methods for more accurate measurement of the Rs.
Collapse
|
13
|
Maser E, Strehse JS. "Don't Blast": blast-in-place (BiP) operations of dumped World War munitions in the oceans significantly increase hazards to the environment and the human seafood consumer. Arch Toxicol 2020; 94:1941-1953. [PMID: 32303806 PMCID: PMC8172487 DOI: 10.1007/s00204-020-02743-0] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2020] [Accepted: 04/06/2020] [Indexed: 11/30/2022]
Abstract
The seas worldwide are threatened by a "new" source of pollution: millions of tons of all kind of warfare material have been dumped intentionally after World War I and II, in addition to mine barriers, failed detonations as well as shot down military planes and sunken ship wrecks carrying munitions. For example, in the German parts of the North and Baltic Sea approximately 1.6 million metric tons of toxic conventional explosives (TNT and others) and more than 5000 metric tons of chemical weapons are present. Such unexploded ordnance (UXO) constitutes a direct risk of detonation with increased human access (fisheries, water sports, cable constructions, wind farms and pipelines). Moreover, after more than 70 years of resting on the seabed, the metal shells of these munitions items corrode, such that chemicals leak out and distribute in the marine environment. Explosive chemicals such as TNT and its derivatives are known for their toxicity and carcinogenicity. In order not to endanger today's shipping traffic or the installation of pipelines and offshore plants by uncontrolled explosions, controlled blast-in-place (BiP) operations of these dangerous relics is a common practice worldwide. However, blast-in-place methods of in situ munitions disposal often result in incomplete (low-order) detonation, leaving substantial quantities of the explosive material in the environment. In the present free field investigation, we placed mussels (Mytilus spp.) as a biomonitoring system in an area of the Baltic Sea where BiP operations took place and where, by visual inspections by scientific divers, smaller and larger pieces of munitions-related materials were scattered on the seafloor. After recovery, the mussels were transferred to our laboratory and analyzed for TNT and its derivatives via gas chromatography and mass spectroscopy. Our data unequivocally demonstrate that low-order BiP operations of dumped munitions in the sea lead to multiple increases in the concentration of TNT and its metabolites in the mussels when compared to similar studies at corroding but still encased mines. For this reason, we explicitly criticize BiP operations because of the resulting environmental hazards, which can ultimately even endanger human seafood consumers.
Collapse
Affiliation(s)
- Edmund Maser
- Institute of Toxicology and Pharmacology for Natural Scientists, University Medical School Schleswig-Holstein, Campus Kiel, Brunswiker Str. 10, 24105, Kiel, Germany.
| | - Jennifer S Strehse
- Institute of Toxicology and Pharmacology for Natural Scientists, University Medical School Schleswig-Holstein, Campus Kiel, Brunswiker Str. 10, 24105, Kiel, Germany
| |
Collapse
|
14
|
Lotufo GR, George RD, Belden JB, Woodley C, Smith DL, Rosen G. Release of Munitions Constituents in Aquatic Environments Under Realistic Scenarios and Validation of Polar Organic Chemical Integrative Samplers for Monitoring. ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY 2019; 38:2383-2391. [PMID: 31365142 DOI: 10.1002/etc.4553] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Revised: 07/16/2019] [Accepted: 07/28/2019] [Indexed: 06/10/2023]
Abstract
Munitions constituents (MC) may be released into aquatic environments as a result of underwater military munitions (UWMM) corrosion and breach. The present study investigated the release of 2,4,6-trinitrotoluene (TNT) and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) from Composition B fragments under 2 realistic exposure scenarios in a large flume with flow set at 15 cm/s: the first represented the release of MC from fully exposed Composition B, and the second represented release through a small hole, simulating a breached munition. Release of MC through a small hole was approximately 10 times lower than from exposed Composition B, demonstrating the strong influence of exposure to flow on release. The rate of release of MC into the flume was similar to that previously reported in a related field experiment, but a similar mass loss resulted in MC concentration in the field >300 times lower, likely by the dilution effect of hydrodynamic transport. The present study corroborates previous findings of release of MC at UWMM sites resulting in concentrations below the toxicity threshold to most species. In the flume water, MC was quantified using frequent grab sampling and polar organic chemical integrative samplers (POCIS). For TNT, POCIS-estimated time-weighted average concentrations were up to 40% higher than those derived from grab samples, whereas for RDX differences were 6% or less, demonstrating that POCIS provide reliable temporal integration of changing environmental concentrations for common MC. Environ Toxicol Chem 2019;38:2383-2391. Published 2019 Wiley Periodicals Inc. on behalf of SETAC. This article is a US government work and, as such, is in the public domain in the United States of America.
Collapse
Affiliation(s)
- Guilherme R Lotufo
- US Army Engineer Research and Development Center, Vicksburg, Mississippi
| | - Robert D George
- US Navy Space and Naval Warfare Systems Center Pacific, San Diego, California
| | - Jason B Belden
- Department of Zoology, Oklahoma State University, Stillwater, Oklahoma, USA
| | - Christa Woodley
- US Army Engineer Research and Development Center, Vicksburg, Mississippi
| | - David L Smith
- US Army Engineer Research and Development Center, Vicksburg, Mississippi
| | - Gunther Rosen
- US Navy Space and Naval Warfare Systems Center Pacific, San Diego, California
| |
Collapse
|
15
|
Beck AJ, van der Lee EM, Eggert A, Stamer B, Gledhill M, Schlosser C, Achterberg EP. In Situ Measurements of Explosive Compound Dissolution Fluxes from Exposed Munition Material in the Baltic Sea. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2019; 53:5652-5660. [PMID: 30997802 DOI: 10.1021/acs.est.8b06974] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Underwater munitions containing millions of tons of toxic explosives are present worldwide in coastal marine waters as a result of unexploded ordnance and intentional dumping. The dissolution flux of solid explosives following corrosion of metal munition housings controls the exposure of biological receptors to toxic munition compounds (MC), including TNT: 2,4,6-trinitrotoluene, RDX: 1,3,5-trinitro-1,3,5-triazinane, and DNB: 1,3-dinitrobenzene. Very little is known about the dissolution behavior of MC in the marine environment. In this work, we exploit a unique marine study site in the Baltic Sea with exposed solid explosives to quantify in situ MC dissolution fluxes using dissolved MC gradients near the exposed explosive surface, as well as benthic chamber incubations. The gradient method gave dissolution fluxes that ranged between 0.001 and 3.2, between 0.0001 and 0.04, and between 0.003 and 1.7 mg cm-2 day-1 for TNT, RDX, and DNB, respectively. Benthic chamber incubations indicated dissolution fluxes of 0.0047-0.277, 0-0.11, and 0.00047-1.45 mg cm-2 day-1 for TNT, RDX, and DNB, respectively. In situ dissolution fluxes estimated in the current study were lower than most dissolution rates reported for laboratory experiments, but they clearly demonstrated that MC are released from underwater munitions to the water column in the Baltic Sea.
Collapse
Affiliation(s)
- Aaron J Beck
- GEOMAR Helmholtz Centre for Ocean Research Kiel , Wischhofstraße 1-3 , 24148 Kiel , Germany
| | - Eefke M van der Lee
- Leibniz-Institute for Baltic Sea Research Warnemünde , Seestraße 15 , 18119 Rostock , Germany
| | - Anja Eggert
- Leibniz-Institute for Baltic Sea Research Warnemünde , Seestraße 15 , 18119 Rostock , Germany
| | - Beate Stamer
- GEOMAR Helmholtz Centre for Ocean Research Kiel , Wischhofstraße 1-3 , 24148 Kiel , Germany
| | - Martha Gledhill
- GEOMAR Helmholtz Centre for Ocean Research Kiel , Wischhofstraße 1-3 , 24148 Kiel , Germany
| | - Christian Schlosser
- GEOMAR Helmholtz Centre for Ocean Research Kiel , Wischhofstraße 1-3 , 24148 Kiel , Germany
| | - Eric P Achterberg
- GEOMAR Helmholtz Centre for Ocean Research Kiel , Wischhofstraße 1-3 , 24148 Kiel , Germany
| |
Collapse
|